dynapcn connection diagrams · 1.4 update cable info for e14-35-10-00 28 august 2014 1.5 update m12...

30
CONNECTION DIAGRAMS DynaPCN Passenger and People Counter Rev 1.5 - 27 October 2015 - DynaPCN_ConnDiag_1.5 ENGLISH

Upload: others

Post on 20-Feb-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

  • ConneCtion diagrams

    dynaPCnPassenger and People Counter

    Rev 1.5 - 27 October 2015 - DynaPCN_ConnDiag_1.5 ENGLISH

  • © 2014 Eurotech

    TrademarksAll trademarks both marked and unmarked appearing in this document are the property of their respective owners.

    Revision historyREVISION DESCRIPTION DATE

    1.0 First release 20 March 20131.1 Minor revision 9 August 20131.2 Minor revision 27 November 20131.3 Added Order Code E14-35-12-00 3 July 20141.4 Update cable info for E14-35-10-00 28 August 20141.5 Update M12 connector information 27 October 2015

  • Table of contents DynaPCN - Connection diagrams

    3

    www.eurotech.comDynaPCN_ConnDiag_1.5

    Table of contentsTrademarks ....................................................................................................................................................... 2Revision history ................................................................................................................................................ 2

    Order Codes ....................................................................................................................................................... 4

    Connections Schemes ...................................................................................................................................... 6DynaPCN 10-01-00 (RS485) ............................................................................................................................ 6

    Single RS485 installation for development (with Development Kit) ............................................................. 6Wide-Gate RS485 installation for development (with Development Kit) ...................................................... 7Single RS485 installation in field .................................................................................................................. 8Wide-Gate RS485 installation in field ........................................................................................................... 9

    DynaPCN 10-20-00 (ETH) .............................................................................................................................. 10Single ETH installation for development (with Development Kit) ............................................................... 10Wide-Gate ETH installation for development (with Development Kit) ........................................................ 11Single ETH installation in field .................................................................................................................... 12Wide-Gate ETH installation in field ............................................................................................................ 13

    DynaPCN 10-20-01 (POE) ............................................................................................................................. 14Single POE installation for development (with Development Kit) ............................................................... 14Wide-Gate POE installation for development (with Development Kit) ....................................................... 15Single POE installation in field ................................................................................................................... 16Wide-Gate POE installation in field ............................................................................................................ 17

    Order Codes in detail ...................................................................................................................................... 18DynaPCN 10-01-00: RS485 passenger and people counter .......................................................................... 18DynaPCN 10-20-00: Ethernet passenger and people counter ....................................................................... 19DynaPCN 10-20-01: POE passenger and people counter ............................................................................. 20E14-35-11-00 .................................................................................................................................................. 21E14-45-10-00 .................................................................................................................................................. 22E14-30-10-00 (POE/Ethernet cable) ............................................................................................................... 23E14-35-10-00 (Multifunction cable 2) .............................................................................................................. 24USB - MiniUSB cable ...................................................................................................................................... 25USB - RS485 cable ......................................................................................................................................... 26E14-35-12-00 (Multifunction cable 1) .............................................................................................................. 27AC PSU .......................................................................................................................................................... 28

  • DynaPCN - Connection diagrams Order Codes

    DynaPCN_ConnDiag_1.54

    DYPCN-10-01-00

    DYPCN-10-20-00

    DYPCN-10-20-01

    E14-35-11-00

    E14-45-10-00

    E14-30-10-00

    E14-35-10-00

    E14-35-12-00

    Order Codes

    ORDER CODES DESCRIPTION PICTURE

    1x DynaPCN 10-01-00: RS485 passenger & people counter

    1x DynaPCN 10-20-00: Ethernet passenger & people counter

    1x DynaPCN 10-20-01: POE passenger & people counter

    1x Cable for: DynaPCN 10-01-00 power supply, Digital IN, RS485; L = 3.0 m

    1x Cable for: DynaPCN 10-20-00 power supply, Digital IN; L = 3.0 m

    1x POE/Ethernet cable; L = 3.0 m

    1x Multifunction cable 2 (Power supply, Digital IN, Wide-Gate); L = 0.8 m

    1x Multifunction cable 1 (Power supply, Digital IN, RS485); L = 0.4 m

  • Order Codes DynaPCN - Connection diagrams

    DynaPCN_ConnDiag_1.55

    www.eurotech.com

    DYPCN-10-01-00-DK0

    DYPCN-10-20-00-DK0

    A

    B

    C

    D

    E

    A

    B

    C

    D

    A

    A

    B

    B

    C

    C

    D

    D

    E

    ORDER CODES DESCRIPTION PICTURE

    Development kit for RS485 passenger & people counter.Content:

    1x USB - MiniUSB cable; L = 3.0 m 1x USB - RS485 cable; L = 3.0 m 1x Multifunction cable 1 (Power supply, Digital IN, RS485); L = 0.4 m 1x Multifunction cable 2 (Power supply, Digital IN, Wide-Gate); L = 0.8 m 1x AC PSU

    Development kit for Ethernet/POE passenger & people counter.Content:

    1x USB - MiniUSB cable; L = 3.0 m 1x POE/Ethernet cable; L = 3.0 m 1x Multifunction cable 2 (Power supply, Digital IN, Wide-Gate); L = 0.8 m 1x AC PSU

  • DynaPCN - Connection diagrams Connections Schemes

    DynaPCN_ConnDiag_1.56

    Connections Schemes

    DynaPCN 10-01-00 (RS485)

    Single RS485 installation for development (with Development Kit)

    ORDER CODE CONTENT

    DYPCN-10-01-00 •1x DynaPCN 10-01-00: RS485 passenger & people counter

    DYPCN-10-01-00-DK0 •1x USB - MiniUSB cable; L = 3.0 m•1x USB - RS485 cable; L = 3.0 m•1x Multifunction cable 1 (Power supply, Digital IN, RS485); L = 0.4 m•1x Multifunction cable 2 (Power supply, Digital IN, Wide-Gate); L = 0.8 m (*)•1x AC PSU

    (*)Notusedinthisconfiguration

    Digital IN

    Master AC PSU

    Multifunction cable 1

    USB - RS485 cable Host PC

    DynaPCN 10-01-00Master

    USB - MiniUSB cable

  • Connections Schemes DynaPCN - Connection diagrams

    DynaPCN_ConnDiag_1.57

    www.eurotech.com

    Wide-Gate RS485 installation for development (with Development Kit)

    ORDER CODE CONTENT

    DYPCN-10-01-00 •1x DynaPCN 10-01-00: RS485 passenger & people counter (master)

    DYPCN-10-01-00 •1x DynaPCN 10-01-00: RS485 passenger & people counter (slave)

    DYPCN-10-01-00-DK0 •1x USB - MiniUSB cable; L = 3.0 m•1x USB - RS485 cable; L = 3.0 m•1x Multifunction cable 1 (Power supply, Digital IN, RS485); L = 0.4 m•1x Multifunction cable 2 (Power supply, Digital IN, Wide-Gate); L = 0.8 m (*)•1x AC PSU (for the master)

    EXTRA •1x AC PSU (for the slave)

    Digital IN

    Master AC PSU

    Slave AC PSU

    Multifunction cable 1

    Multifunction cable 2

    USB - RS485 cable Host PC

    DynaPCN 10-01-00Master

    DynaPCN 10-01-00Slave

    USB - MiniUSB cable

  • DynaPCN - Connection diagrams Connections Schemes

    DynaPCN_ConnDiag_1.58

    Single RS485 installation in field

    ORDER CODE CONTENT

    DYPCN-10-01-00 •1x DynaPCN 10-01-00: RS485 passenger & people counterE-14-35-11-00 •1x Cable for: DynaPCN 10-01-00 power supply, Digital IN, RS485; L = 3.0 m

    EXTRA •1x USB - MiniUSB cable; L = 3.0 m

    Digital IN

    E-14-35-11-00

    Master PSURS485

    DynaPCN 10-01-00Master

    USB - MiniUSB cable

    Setup

    Host PC

  • Connections Schemes DynaPCN - Connection diagrams

    DynaPCN_ConnDiag_1.59

    www.eurotech.com

    Wide-Gate RS485 installation in field

    ORDER CODE CONTENT

    DYPCN-10-01-00 •1x DynaPCN 10-01-00: RS485 passenger & people counter (master)

    DYPCN-10-01-00 •1x DynaPCN 10-01-00: RS485 passenger & people counter (slave)

    E-14-35-11-00 •1x Cable for: DynaPCN 10-01-00 power supply, Digital IN, RS485; L = 3.0 m

    E-14-35-10-00 •1x Multifunction cable 2 (Power supply, Digital IN, Wide-Gate); L = 0.8 m

    EXTRA •1x USB - MiniUSB cable; L = 3.0 m

    Digital INSlave PSU

    E-14-35-11-00

    Master PSURS485

    E-14-35-10-00

    DynaPCN 10-01-00Master

    DynaPCN 10-01-00Slave

    USB - MiniUSB cable

    Setup

    Host PC

  • DynaPCN - Connection diagrams Connections Schemes

    DynaPCN_ConnDiag_1.510

    DynaPCN 10-20-00 (ETH)

    Single ETH installation for development (with Development Kit)

    ORDER CODE CONTENT

    DYPCN-10-20-00 •1x DynaPCN 10-20-00: ETH passenger & people counter

    DYPCN-10-20-00-DK0 •1x USB - MiniUSB cable; L = 3.0 m•1x POE/Ethernet cable; L = 3.0 m•1x Multifunction cable 2 (Power supply, Digital IN, Wide-Gate); L = 0.8 m•1x AC PSU

    Digital IN

    Master AC PSU

    POE/Ethernet cable Multifunction cable 2

    Ethernet DynaPCN 10-20-00Master

    USB - MiniUSB cableHost PC

  • Connections Schemes DynaPCN - Connection diagrams

    DynaPCN_ConnDiag_1.511

    www.eurotech.com

    Wide-Gate ETH installation for development (with Development Kit)

    ORDER CODE CONTENT

    DYPCN-10-20-00 •1x DynaPCN 10-20-00: ETH passenger & people counter (master)

    DYPCN-10-01-00 •1x DynaPCN 10-01-00: RS485 passenger & people counter (slave)

    DYPCN-10-20-00-DK0 •1x USB - MiniUSB cable; L = 3.0 m•1x POE/Ethernet cable; L = 3.0 m•1x Multifunction cable 2 (Power supply, Digital IN, Wide-Gate); L = 0.8 m•1x AC PSU (for the master)

    EXTRA •1x AC PSU (for the slave)

    DynaPCN 10-01-00Slave

    Ethernet

    Digital IN

    Master AC PSU

    Slave AC PSU

    POE/Ethernet cable Multifunction cable 2

    DynaPCN 10-20-00Master

    USB - MiniUSB cableHost PC

  • DynaPCN - Connection diagrams Connections Schemes

    DynaPCN_ConnDiag_1.512

    Single ETH installation in field

    ORDER CODE CONTENT

    DYPCN-10-20-00 •1x DynaPCN 10-20-00: ETH passenger & people counter

    E14-30-10-00 •1x POE/Ethernet cable; L = 3.0 m

    E14-45-10-00 •1x Cable for: DynaPCN 10-20-00 power supply, Digital IN; L = 3.0 m

    EXTRA •1x USB - MiniUSB cable; L = 3.0 m

    Digital IN

    Master PSU

    DynaPCN 10-20-00Master

    E14-30-10-00E14-45-10-00

    Ethernet

    USB - MiniUSB cable

    Setup

    Host PC

  • Connections Schemes DynaPCN - Connection diagrams

    DynaPCN_ConnDiag_1.513

    www.eurotech.com

    Wide-Gate ETH installation in field

    ORDER CODE CONTENT

    DYPCN-10-20-00 •1x DynaPCN 10-20-00: ETH passenger & people counter (master)

    DYPCN-10-01-00 •1x DynaPCN 10-01-00: RS485 passenger & people counter (slave)

    E14-30-10-00 •1x POE/Ethernet cable; L = 3.0 m

    E14-35-10-00 •1x Multifunction cable 2 (Power supply, Digital IN, Wide-Gate); L = 0.8 m

    EXTRA •1x AC power supply (for the slave)

    Digital IN

    Slave PSU

    Master PSU

    E14-35-10-00

    DynaPCN 10-20-00Master

    DynaPCN 10-01-00Slave

    E14-30-10-00

    Ethernet

    USB - MiniUSB cable

    Setup

    Host PC

  • DynaPCN - Connection diagrams Connections Schemes

    DynaPCN_ConnDiag_1.514

    DynaPCN 10-20-01 (POE)

    Single POE installation for development (with Development Kit)

    ORDER CODE CONTENT

    DYPCN-10-20-01 •1x DynaPCN 10-20-00: POE passenger & people counter

    DYPCN-10-20-00-DK0 •1x USB - MiniUSB cable; L = 3.0 m•1x POE/Ethernet cable; L = 3.0 m•1x Multifunction cable 2 (Power supply, Digital IN, Wide-Gate); L = 0.8 m•1x AC PSU (*)

    (*)Notusedinthisconfiguration

    Digital IN

    POE/Ethernet cable Multifunction cable 2

    POE DynaPCN 10-20-01Master

    USB - MiniUSB cableHost PC

  • Connections Schemes DynaPCN - Connection diagrams

    DynaPCN_ConnDiag_1.515

    www.eurotech.com

    Wide-Gate POE installation for development (with Development Kit)

    ORDER CODE CONTENT

    DYPCN-10-20-01 •1x DynaPCN 10-20-00: POE passenger & people counter

    DYPCN-10-01-00 •1x DynaPCN 10-01-00: RS485 passenger & people counter (slave)

    DYPCN-10-20-00-DK0 •1x USB - MiniUSB cable; L = 3.0 m•1x POE/Ethernet cable; L = 3.0 m•1x Multifunction cable 2 (Power supply, Digital IN, Wide-Gate); L = 0.8 m•1x AC PSU (for the slave)

    DynaPCN 10-01-00Slave

    POE

    Digital IN

    Slave AC PSU

    POE/Ethernet cable Multifunction cable 2

    DynaPCN 10-20-01Master

    USB - MiniUSB cableHost PC

  • DynaPCN - Connection diagrams Connections Schemes

    DynaPCN_ConnDiag_1.516

    Single POE installation in field

    ORDER CODE CONTENT

    DYPCN-10-20-01 •1x DynaPCN 10-20-00: POE passenger & people counter

    E14-30-10-00 •1x POE/Ethernet cable; L = 3.0 m

    E14-45-10-00 •1x Cable for: DynaPCN 10-20-00 power supply, Digital IN; L = 3.0 m

    EXTRA •1x USB - MiniUSB cable; L = 3.0 m

    Digital IN

    USB - MiniUSB cable

    E14-45-10-00

    Setup

    Host PC

    DynaPCN 10-20-01Master

    E14-30-10-00

    Ethernet

  • Connections Schemes DynaPCN - Connection diagrams

    DynaPCN_ConnDiag_1.517

    www.eurotech.com

    Wide-Gate POE installation in field

    ORDER CODE CONTENT

    DYPCN-10-20-01 •1x DynaPCN 10-20-00: POE passenger & people counter

    DYPCN-10-01-00 •1x DynaPCN 10-01-00: RS485 passenger & people counter (slave)

    E14-30-10-00 •1x POE/Ethernet cable; L = 3.0 m

    E14-35-10-00 •1x Multifunction cable 2 (Power supply, Digital IN, Wide-Gate); L = 0.8 m

    EXTRA •1x AC PSU (for the slave)

    Digital IN

    USB - MiniUSB cable

    Slave PSU

    E14-35-10-00

    Setup

    Host PC

    DynaPCN 10-20-01Master

    DynaPCN 10-01-00Slave

    E14-30-10-00

    POE

  • DynaPCN - Connection diagrams Order Codes in detail

    DynaPCN_ConnDiag_1.518

    M2M1

    A Power supply +B Power supply -C Digital IN 1 +D Digital IN 1 -E Digital OUT 1 V+F Digital OUT 1G Digital OUT 1 GNDH RS485_1 GNDJ RS485_1 +K RS485_1 -L ReservedM Reserved

    A ReservedB ReservedC Digital OUT 2 V+D Digital OUT 2E Digital IN 2+F Digital IN 2-G Digital OUT 2 GNDH RS485_WG GNDJ RS485_WG +K RS485_WG -L ReservedM Reserved

    Order Codes in detail

    DynaPCN 10-01-00: RS485 passenger and people counter

    CONNECTOR CHARACTERISTICS:Type: 12-pin male circular conn. P/N: Lumberg 031512

    MATING CONNECTOR CHARACTERISTICS:Type: 12-pin female circular conn. P/N: Lumberg 032212

    CONNECTOR CHARACTERISTICS:Type: 12-pin female circular conn. P/N: Lumberg 030512

    MATING CONNECTOR CHARACTERISTICS:Type: 12-pin male circular conn. P/N: Lumberg 033212

    PIN # SIGNAL PIN # SIGNAL

  • Order Codes in detail DynaPCN - Connection diagrams

    DynaPCN_ConnDiag_1.519

    www.eurotech.com

    M2M1

    1 ETH_TX+2 ETH_RX+3 ETH_TX-4 ETH_RX-

    A Power IN +B Power IN -C Digital OUT 2 V+D Digital OUT 2E Digital IN 2 +F Digital IN 2 -G Digital OUT 2 GNDH RS485_WG GNDJ RS485_WG +K RS485_WG -L Digital IN 1 +M Digital IN 1 -

    DynaPCN 10-20-00: Ethernet passenger and people counter

    CONNECTOR CHARACTERISTICS:Tipo: 4-pin M12 female circular conn. P/N: Lumberg 0986EFC152

    MATING CONNECTOR CHARACTERISTICS:Tipo: 4-pin M12 male circular conn. P/N: Conec 43-00161

    CONNECTOR CHARACTERISTICS:Tipo: 12-pin female circular conn.P/N: Lumberg 030512

    MATING CONNECTOR CHARACTERISTICS:Tipo: 12-pin male circular conn P/N: Lumberg 033212

    PIN # SIGNAL PIN # SIGNAL

  • DynaPCN - Connection diagrams Order Codes in detail

    DynaPCN_ConnDiag_1.520

    M2M1

    1 ETH_TX+2 ETH_RX+3 ETH_TX-4 ETH_RX-

    A ReservedB ReservedC Digital OUT 2 V+D Digital OUT 2E Digital IN 2 +F Digital IN 2 -G Digital OUT 2 GNDH RS485_WG GNDJ RS485_WG +K RS485_WG -L Digital IN 1 +M Digital IN 1 -

    DynaPCN 10-20-01: POE passenger and people counter

    CONNECTOR CHARACTERISTICS:Tipo: 4-pin M12 female circular conn. P/N: Lumberg 0986EFC152

    MATING CONNECTOR CHARACTERISTICS:Tipo: 4-pin M12 male circular conn. P/N: Conec 43-00161

    CONNECTOR CHARACTERISTICS:Tipo: 12-pin female circular conn.P/N: Lumberg 030512

    MATING CONNECTOR CHARACTERISTICS:Tipo: 12-pin male circular conn P/N: Lumberg 033212

    PIN # SIGNAL PIN # SIGNAL

  • Order Codes in detail DynaPCN - Connection diagrams

    DynaPCN_ConnDiag_1.521

    www.eurotech.com

    Con1

    E14-35-11-00USE

    • Supply power to DynaPCN 10-01-00

    • Use the Digital IN lines

    • Use the RS485 lines

    DESCRIPTION

    • FromCon1:12-pinFemalecircularconnector↔To7xrawwires

    LENGHT

    • 3.0 m

    Connector detailsNAME CONNECT TO CONNECTOR TYPECon1 M1 of Master device 12-pin female circular connector; Lumberg 032212

    Con1 pinoutPIN # SIGNAL TO WIRE PIN # SIGNAL TO WIRE

    A Power IN + White H RS485_1 GND GreyB Power IN - Brown J RS485_1 + PinkC Digital IN 1+ Green K RS485_1 - BlueD Digital IN 1- Yellow

    Pins not in table are not connected

    7x Raw wires

    Con 1 - Female connector

  • DynaPCN - Connection diagrams Order Codes in detail

    DynaPCN_ConnDiag_1.522

    Con1

    E14-45-10-00

    4x Raw wires

    USE

    • Supply power to DynaPCN 10-20-00

    • Use the Digital IN lines

    DESCRIPTION

    • From4xrawwires↔ToCon1:12-pinMalecircularconnector

    LENGHT

    • 3.0 m

    Connector detailsNAME CONNECT TO CONNECTOR TYPECon1 M2 of Master device 12-pin male circular connector; Lumberg 033212

    Con1 pinoutPIN # SIGNAL TO WIRE PIN # SIGNAL TO WIRE

    A Power IN + White L Digital IN 1+ GreenB Power IN - Brown M Digital IN 1- Yellow

    Pins not in table are not connected

    Con 1 - Male connector

  • Order Codes in detail DynaPCN - Connection diagrams

    DynaPCN_ConnDiag_1.523

    www.eurotech.com

    Con1 Con2

    E14-30-10-00 (POE/Ethernet cable)

    Connector detailsNAME CONNECT TO CONNECTOR TYPECon1 POE / Ethernet network soket

    NOTE: If the network is POE, Con1 also powers the DYPCN-10-20-01

    Male RJ45 connector

    Con2 M1of Master device 4-pin M12 male circular connector

    Con2 pinoutPIN # SIGNAL PIN # SIGNAL

    1 ETH_TX+ 3 ETH_TX-2 ETH_RX+ 4 ETH_RX-

    USE

    • Connect the DynaPCN 10-20-0x to the POE/Ethernet network

    • Supply power to DynaPCN 10-20-01

    DESCRIPTION

    • FromCon1:RJ45maleconnector↔ToCon2:4-pinM12malecircularconnector

    LENGHT

    • 3.0 m

    Con 2 - Male connectorCon 1 - Male connector

  • DynaPCN - Connection diagrams Order Codes in detail

    DynaPCN_ConnDiag_1.524

    Con1

    Con2

    Con3

    E14-35-10-00 (Multifunction cable 2)USE

    • Supply power to DynaPCN 10-20-00

    • Use the Digital IN lines

    • Supply power to the Slave device (Wide-Gate only)

    • Connect Master and Slave devices together (Wide-Gate only)

    DESCRIPTION

    • FromCon1:12-pinMalecircularconnector↔ToCon2:6-wayscrewnylonterminalblock+Con3:12-pinfemale circular connector

    LENGHT

    • 0.8 m

    Connector detailsNAME CONNECT TO CONNECTOR TYPECon1 M2 of Master device 12-pin male circular connector; Lumberg 033212Con2 DynaPCN 10-20-00 power supply

    Digital IN lines6-way screw nylon terminal block; RS Components 492-8687

    Con3 M1 of Slave device 12-pin female circular connector; Lumberg 032212

    Con2 pinoutPIN # SIGNAL CONNECTED TO PIN # SIGNAL CONNECTED TO

    1(A) Power IN + Con1 – Pin A 4 (B) Digital IN 1- Con1 – Pin M2 (A) Power IN - Con1 – Pin B 5 Power IN + Con3 – Pin A3 (B) Digital IN 1+ Con1 – Pin L 6 Power IN – Con3 – Pin B

    (A) Use only with DynaPCN 10-20-00 (B) Use only with DynaPCN 10-20-00 and DynaPCN 10-20-01

    Con 3 - Female connectorCon 2 - Terminal BlockCon 1 - Male connector

  • Order Codes in detail DynaPCN - Connection diagrams

    DynaPCN_ConnDiag_1.525

    www.eurotech.com

    Con1 Con2

    5 4 3 2 14 3 2 1

    USB - MiniUSB cable

    Connector detailsNAME CONNECT TO CONNECTOR TYPECon1 USB port of Host PC Male USB type “A” connectorCon2 Mini-USB port of DynaPCN 10-20-0x Male Mini-USB type “B” connector

    USE

    • Connect the DynaPCN to the Host PC

    DESCRIPTION

    • FromCon1:MaleUSBtype“A”connector↔ToCon2:MaleMini-USBtype“B”connector

    LENGHT

    • 3.0 m

    Con 2 - Male connectorCon 1 - Male connector

  • DynaPCN - Connection diagrams Order Codes in detail

    DynaPCN_ConnDiag_1.526

    Con1

    4 3 2 1

    Con2

    1

    USB - RS485 cableUSE

    • Connect the USB port of the Host PC to Cn2 of the Multifunction cable 1

    DESCRIPTION

    • FromCon1:MaleUSBtype“A”connector↔ToCon2:MaleDB9connector

    LENGHT

    • 3.0 m

    Connector detailsNAME CONNECT TO CONNECTOR TYPECon1 USB port of Host PC Male USB type “A” Con2 Con3 of the Multifuncion Adapter 1 Male DB9

    Con2 pinoutPIN # SIGNAL

    1 Data -2 Data +5 Ground

    Con 2 - Male connector Con 1 - Male connector

  • Order Codes in detail DynaPCN - Connection diagrams

    DynaPCN_ConnDiag_1.527

    www.eurotech.com

    Con1

    Con2

    1

    Con3

    Con4

    E14-35-12-00 (Multifunction cable 1)USE

    • Supply power, the Digital IN lines and the RS485 lines to the DynaPCN 10-01-00

    DESCRIPTION

    • From Con1: 2-way screw nylon terminal block + Con2: 3-way screw nylon terminal block + Con3: female DB9connector↔ToCon4:12-pinfemalecircularconnector

    LENGHT

    • 0.4 m

    Connector detailsNAME CONNECT TO CONNECTOR TYPECon1 Power supply 2-way screw nylon terminal blockCon2 Digital IN lines 3-way screw nylon terminal blockCon3 RS485 Female DB9 connectorCon4 M1 of DynaPCN 10-01-00 12-pin female circular connector

    Con4 pinoutPIN # SIGNAL CONNECTED TO PIN # SIGNAL CONNECTED TO

    A Power IN + Con1 – Pin 1 F Not Connected -

    B Power IN - Con2 – Pin 2 D Digital IN1 - Con2 – Pin 3

    J RS485_1 + Con3 – Pin 2 G Not Connected -

    K RS485_1 - Con3 – Pin 1 E Not Connected -

    H RS485_1 GND Con3 – Pin 5 L Power supply + (*) Con1 – Pin 1

    C Digital IN1 + Con2 – Pin 1 M Power supply - (*) Con1 – Pin 2 (*) for slave device

    Con 3 - Female connectorCon 2 - Terminal blockCon 1 - Terminal block Con 4 - Female connector

  • DynaPCN - Connection diagrams Order Codes in detail

    DynaPCN_ConnDiag_1.528

    AC PSUUSE

    • Supply power to DynaPCN 10-01-00 / DynaPCN 10-20-00

    DESCRIPTION

    • AC power supply

  • Notes

  • EUROPE

    ITALY

    EUROTECH Tel: +39 0433.485.411 Fax: +39 0433.485.499 E-mail: [email protected] E-mail: [email protected] Web: www.eurotech.com

    UNITED KINGDOM

    EUROTECH Tel: +44 (0) 1223.403410 Fax: +44 (0) 1223.410457 E-mail: [email protected] E-mail: [email protected] Web: www.eurotech.com

    FRANCE

    EUROTECH Tel: +33 04.72.89.00.90 Fax: +33 04.78.70.08.24 E-mail: [email protected] E-mail: [email protected] Web: www.eurotech.com

    AMERICAS

    USA

    EUROTECH Toll free: +1 888.941.2224 Tel: +1 301.490.4007 Fax: +1 301.490.4582 E-mail: [email protected] E-mail: [email protected] Web: www.eurotech-inc.com

    P T F E E W

    ASIA

    JAPAN

    ADVANET Tel: +81 86.245.2861 Fax: +81 86.245.2860 E-mail: [email protected] E-mail: [email protected] Web: www.advanet.jp

    WORLD SUPPORT

    HEADQUARTERS

    EUROTECH Via Fratelli Solari, 3/a 33020 Amaro (UD) – Italy Tel: +39 0433.485.411 Fax: +39 0433.485.499 E-mail: [email protected] Web: www.eurotech.com

    For your local contact please refer to: www.eurotech.com/contacts

    Specifications and features are subject to change without notice. All trademarks and trade names are the property of their respective owners.