DXc Range Data Sheet 1, 2 and 4 loop, networkable, multi-protocol, analogue addressable fire alarm control panel Product Overview The Morley-IAS DX Connexion panel is ideally suited for use in the protection of small to medium sized buildings. All in all, a compact, high performance, feature rich, economical fire alarm control panel designed to help both the installer and the end user. The DX Connexion is an enhancement of the Morley-IAS Dimension panel range, connecting the traditional Morley-IAS qualities of reliability, flexibility and value with advanced features and intuitive functionality. The multi-protocol DX Connexion range of fire alarm control panels has been developed to be the most time efficient fire panel on the market to install. Simply fix the control panel to the wall, connect the field wiring, power up and in as few as five button presses you can have a compliant, working fire alarm system. The panel’s large graphical display provides a clear menu structure making the whole initial set-up process quick, clear and intuitive.

Upload: nguyendan

Post on 17-May-2018

221 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: DXc Range Data Sheet - esser-systems.com Range Data Sheet 1, 2 and 4 loop, ... devices or zones to be imported from an Excel spread sheet, saving further time. ... illumination Control

DXc Range Data Sheet1, 2 and 4 loop, networkable,multi-protocol, analogue addressable fire alarm control panel

Product OverviewThe Morley-IAS DX Connexion panel is ideally suited for use in the protection of small to medium sized buildings. All in all, a compact, high performance, feature rich, economical fire alarm control panel designed to help both the installer and the end user.

The DX Connexion is an enhancement of theMorley-IAS Dimension panel range, connecting the traditional Morley-IAS qualities of reliability, flexibility and value with advanced features and intuitive functionality.

The multi-protocol DX Connexion range of fire alarm control panels has been developed to be the most time efficient fire panel on the market to install. Simply fix the control panel to the wall, connect the field wiring, power up and in as few as five button presses you can have a compliant, working fire alarm system. The panel’s large graphical display provides a clear menu structure making the whole initial set-up process quick, clear and intuitive.

Page 2: DXc Range Data Sheet - esser-systems.com Range Data Sheet 1, 2 and 4 loop, ... devices or zones to be imported from an Excel spread sheet, saving further time. ... illumination Control

Product Overview (Continued...)Additionally, programming the control panel couldn’t be easier. Complex configuration can be achieved by using either the panel’s mobile phone style key pad or by using the Windows PC programming tool supplied with the panel. The flexible PC programming tool also allows text messages for devices or zones to be imported from an Excel spread sheet, saving further time. Panel Features

• Optional40or80zonealarmLEDs• Easy5key-pressset-up• LargeblueLCDdisplay• SupportsUSBupload/download• Mobilephonestylekeypadandnavigationkeys• Optiontouploadacompanylogo

Software Features• PCconfigurationsoftware(suppliedwithpanel)• 80firezones(canbeusedwithorwithoutLEDs)• 7daytimers• Eventlogging• Onboarddiagnostics• Classchangefunction• Coincidenceandverificationdetectionforfalsealarm management• Sensitivityadjustmente.g.betweendayandnight• Input/outputlogic

Hardware Features• Batterybackedreal-timeclock(2&4loop)• 2independentsoundercircuits• 500mAmulti-protocolloopdriver• 2xonboardmonitoredinputs• Optionalprogrammablekeyswitchforselectedfunctions• Plug-inconnectors

Output Relays:Fire relay: Single pole changeover 24V DC 1AFault relay: Single pole changeover 24V DC 1AAux relay: Programmable single pole changeover24V DC 1A

Onboard Data Ports:1xRS485(Repeaterconnection)1 x PC Programming Port4

Optional Ports:RS232 third party protocol interface

Sounder Circuits:2 output circuits, 1A per circuit.1

Networking Features• Networkupto16loops(16x1looppanels,8x2loop panels,4x4looppanelsoranymixuptomax16loops)• Truepeer-to-peerandfaulttolerantnetworkforhigh system reliability• BS5839part1compliantnetwork

UserInterfaceDisplay 6x40character(240x64pixels)blue liquid crystal display with backlight illumination

Control Keys Evacuate,Silence/Resound,Mute Buzzer,ExtendDelay,SystemReset, Show Alarm Zones

Programmable 2 independent programmable function Keys keysandLEDindicators

Programming 12 button alpha numeric key pad inc Keys cancel and return keys plus 4 navigation keys and an OK key

Indicators Fire,Fault,Disablement,Test,Buzzer Muted, Delayed Mode, Sounders Silenced, Sounders Disabled and Power. AlsodedicatedfaultLEDsforSystem Fault,SupplyFaultandEarthFault.40 or80LEDfirezoneindicatorsoptional.

LoopCapacity2:500mAperloop

Protocol DevicesSupportsApollo(Xplorer,XP95andDiscovery),Hochiki (ESP)&SystemSensorprotocoldevices.

Number of Apollo Hochiki SystemDevices Protocol Protocol Sensor Protocol

126 -

198 - -

Page 3: DXc Range Data Sheet - esser-systems.com Range Data Sheet 1, 2 and 4 loop, ... devices or zones to be imported from an Excel spread sheet, saving further time. ... illumination Control

Mechanical DXc1 DXc2 DXc4Dimensions [mm] (H x W x D) 260x390x147 391.5x390x147 391.5x390x147

Weight(ExcludingBatteries) 4kg 4.5kg 4.5kg

Colour RAL9002-Greywhite RAL9002-Greywhite RAL9002-Greywhite

Mounting Holes 3 3 3

Knockouts(20mm) Top:25x Top:25x Top:25x Bottom:2x Bottom:4x Bottom:4x

Operating Temperature 0°Cto+40°C 0°Cto+40°C 0°Cto+40°C

Relative Humidity 5%-95%non-condensing 5%-95%non-condensing 5%-95%non-condensing

IP30(EN6059) IP30(EN6059) IP30(EN6059)

Material Mildsteelsheetrearenclosure.ABSplasticfrontcovertoBSEN60950.Alldisplays and controls are carried on the enclosure door.

DXc1 DXc2 DXc4Operating Voltage 230VAC (+15%,-15%)50-60Hz 230VAC (+15%,-15%)50-60Hz 230VAC (+15%,-15%)50-60Hz

PSURating 24V DC 2A 24V DC 4A 24V DC 4A

Stand-byBatteries5 2x7Ah 2x17Ah 2x17Ah

Stand-byBattery Duration3 Stand alone: 24 hours Standalone:72hours. Standalone:48hours. (BasedonApollodevices) back-up with either With network card or With network card or network card or repeater repeater connected: repeater connected: connected 48hours 24hours

Auxilliary Output1 +24VDC250mAfused +24VDC250mAfused +24VDC250mAfused

Notes:1 Maximum available current will be dependent on full control panel loading.2 Only one protocol can be selected within the control panel.3 Stand-by dependent on type and quantity of devices installed.4RequiresRS232orUSBinterfacelead.5 Not included.

Electrical

DXc1 / DXc2 / DXc4

DXc2 / DXc4

260

390

147

391.5

390

147

Page 4: DXc Range Data Sheet - esser-systems.com Range Data Sheet 1, 2 and 4 loop, ... devices or zones to be imported from an Excel spread sheet, saving further time. ... illumination Control

Part Numbers Accessories

795-114 BezelkitDXc1plusExtensionBox795-115 BezelkitDXc2/4plusExtensionBox795-116 CustomkeyplatecoverforExtensionBox795-118 Keyswitchkit795-119 RackmountingkitDXc1795-120 RackmountingkitDXc2/4795-121 Extensionbackbox795-122 RS232Kit(forthirdpartyprotocol)795-124 80zoneLEDcardkit797-090 DXcEN54-4compliantPSU020-909 DXcCompactMimic020-910 DXcExpansionMimicPCB020-891 USBisolatedupload/downloadleadSee price list Visualeyez options

Caburn House

2BBrooksRoad

Lewes,E.Sussex

BN72BYUK

T: +44(0)1273897000

F: +44(0)1273376894

E: [email protected]

www.morley-ias.co.uk

For further details on these or any other Morley-IAS products pleasecontactyourlocaldistributor,Morley-IASBusinessManager or via our contact details found below. Morley-IAS by Honeywell - Providing a control panel solution, for fire industry professionals, committed to supporting our device partners.

DXc System Example

Every care has been taken in the preparation of this datasheet but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice.©Morley-IASbyHoneywell2014

DO

C R

EF:

M10

0-D

Xc-

R1-

(021

4)

Panels714-001-111 DXc1OneloopFireAlarmControlPanel714-001-221 DXc2TwoloopFireAlarmControlPanel714-001-241 DXc4FourloopFireAlarmControlPanel

709-601-001 MorleyActiveRepeater709-701-001 MorleyPassiveRepeater795-097 EngineersSPK(Software Programming Kit)

795-099 Networkcard795-101 BlankcoverkitforExtensionBox795-102 40zoneLEDcardkit795-111 2loopexpansioncard795-112 BezelkitforDXc1(mm:h:342xw:471.5xd:13)

795-113 BezelkitforDXc2/4(mm:h:473.5xw:471.5xd:13)