duralux vision panelsvariations the duralux vision panel is available in the following formats:...

3
Tel. 01959 577 727 | [email protected] | Kimberley Business Park, Blackness Lane, Keston, Kent BR2 6HL | www.kingswaygroup.co.uk Installation Using the template mark out the cut out area on the door including the 12 bolt holes. Cut out the marked area and drill the 12 holes. Line the aperture with the intumescent liner and place the vision panel carefully in the aperture. Place the stud side fascia on to the door making sure each weld stud is locating in a drilled hole (this is the patient side fascia). Position the other fascia on the door so that the countersunk holes line up with the drilled holes on the door and start attaching both fascia’s together with the bolt provided. Take care to ensure that the spindle of the thumb turn (if specified) is located centrally in the thumb turn hole on the patient side then start tightening the bolts Fix the thumb turn on to the spindle with a 2.5mm hex bit making sure there is a minimal amount of movement backwards and forwards and that it is not binding on the edges of the thumb turn bezel. Final tightening of the bolts – take care not to over tighten as this will result in the screws shearing. Operation and Maintenance Operation To allow vision through the panel the thumb turn or staff control is used to align the central pane so that the clear stripes line up. Where a hold open control is used the panel can be left in the open position where . Maintenance Periodic checks should be made to the fixings to ensure they are all tight and that they have not been tampered with. The control should be checked to ensure it is functioning smoothly and that the grub screw that holds the thumb turn on is tight. Cleaning Cleaning of Duralux panels should be done with caution as they should not come in contact with liquids of any kind. Where cleaning is required it should be made with a damp cloth and a mild detergent if needed. Duralux vision panels are the original high strength fit for purpose vision panel that has been designed specifically for challenging healthcare environments. PRODUCT DATA SHEET Duralux VISION PANELS

Upload: others

Post on 26-Apr-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Duralux VISION PANELSVariations The Duralux vision panel is available in the following formats: PRODUCT DATA SHEET Fire Ratings 44mm panels are suitable for FD30 doors. 54mm panels

Tel. 01959 577 727 | [email protected] | Kimberley Business Park, Blackness Lane, Keston, Kent BR2 6HL | www.kingswaygroup.co.uk

Installation

• Using the template mark out the cut out area on the door including the 12 bolt holes.• Cut out the marked area and drill the 12 holes.• Line the aperture with the intumescent liner and place the vision panel carefully in

the aperture.• Place the stud side fascia on to the door making sure each weld stud is locating in a

drilled hole (this is the patient side fascia).• Position the other fascia on the door so that the countersunk holes line up with

the drilled holes on the door and start attaching both fascia’s together with thebolt provided.

• Take care to ensure that the spindle of the thumb turn (if specified) is located centrallyin the thumb turn hole on the patient side then start tightening the bolts

• Fix the thumb turn on to the spindle with a 2.5mm hex bit making sure there is aminimal amount of movement backwards and forwards and that it is not binding onthe edges of the thumb turn bezel.

• Final tightening of the bolts – take care not to over tighten as this will result in thescrews shearing.

Operation and Maintenance

OperationTo allow vision through the panel the thumb turn or staff control is used to align the central pane so that the clear stripes line up. Where a hold open control is used the panel can be left in the open position where .

MaintenancePeriodic checks should be made to the fixings to ensure they are all tight and that they have not been tampered with. The control should be checked to ensure it is functioning smoothly and that the grub screw that holds the thumb turn on is tight.

CleaningCleaning of Duralux panels should be done with caution as they should not come in contact with liquids of any kind. Where cleaning is required it should be made with a damp cloth and a mild detergent if needed.

Duralux vision panels are the original high strength fit for purpose vision panel that has been designed specifically for challenging healthcare environments.

PRODUCT DATA SHEET

Duralux VISION PANELS

Page 2: Duralux VISION PANELSVariations The Duralux vision panel is available in the following formats: PRODUCT DATA SHEET Fire Ratings 44mm panels are suitable for FD30 doors. 54mm panels

PRODUCT DATA SHEET

Cross Section

Below is a cross sectional diagram of the Duralux vision panel.

Tel. 01959 577 727 | [email protected] | Kimberley Business Park, Blackness Lane, Keston, Kent BR2 6HL | www.kingswaygroup.co.uk

A

A

44

405

SECTION A-A

TRIDENT 10mm GLASS

TRIDENT 19mm GLASS

Page 3: Duralux VISION PANELSVariations The Duralux vision panel is available in the following formats: PRODUCT DATA SHEET Fire Ratings 44mm panels are suitable for FD30 doors. 54mm panels

Variations

The Duralux vision panel is available in the following formats:

PRODUCT DATA SHEET

Fire Ratings44mm panels are suitable for FD30 doors.54mm panels are suitable for FD60 doors

GuaranteeLife Time Guarantee**For faulty manufacture and not for damage

NBS SpecificationTypical description would read:Duralux D4400 Vision Panel with key and thumb turn control

Design OptionAC - Auto Close. The panel cannot be left in the open positionU-Ultra. The stripe width is twice as large.ACU - Auto Close Ultra. The panelcannot be left in the open position and thestripe width is twice as large.PP - Picture Panel. The panel has a fullcolour image printed on it.SC-Soft Close. The panel has a soft closemechanism built in.

Code Size (mm)Cut Out

Fascia DoorThickness

Control Type Design Option

D4400 410 x 410 470 x 470 44mm Key / Knob AC/ACU/U/PP/SC

D4401 410 x 410 470 x 470 44mm Key/Key AC/ACU/U/PP/SC

D4402 410 x 410 470 x 470 44mm Knob/Knob AC/ACU/U/PP/SC

D4403 410 x 410 470 x 470 44mm Key only AC/ACU/U/PP/SC

D4404 410 x 410 470 x 470 44mm Knob only AC/ACU/U/PP/SC

D4500 410 x 410 470 x 470 54mm Key / Knob AC/ACU/U/PP/SC

D4501 410 x 410 470 x 470 54mm Key/Key AC/ACU/U/PP/SC

D4502 410 x 410 470 x 470 54mm Knob/Knob AC/ACU/U/PP/SC

D4503 410 x 410 470 x 470 54mm Key only AC/ACU/U/PP/SC

D4504 410 x 410 470 x 470 54mm Knob only AC/ACU/U/PP/SC

D8400 805 x 255 865 x 315 44mm Key / Knob AC/ACU/U/PP/SC

D8401 805 x 255 865 x 315 44mm Key/Key AC/ACU/U/PP/SC

D8402 805 x 255 865 x 315 44mm Knob/Knob AC/ACU/U/PP/SC

D8403 805 x 255 865 x 315 44mm Key only AC/ACU/U/PP/SC

D8404 805 x 255 865 x 315 44mm Knob only AC/ACU/U/PP/SC

D8500 805 x 255 865 x 315 54mm Key / Knob AC/ACU/U/PP/SC

D8501 805 x 255 865 x 315 54mm Key/Key AC/ACU/U/PP/SC

D8502 805 x 255 865 x 315 54mm Knob/Knob AC/ACU/U/PP/SC

D8503 805 x 255 865 x 315 54mm Key only AC/ACU/U/PP/SC

D8504 805 x 255 865 x 315 54mm Knob only AC/ACU/U/PP/SC

Tel. 01959 577 727 | [email protected] | Kimberley Business Park, Blackness Lane, Keston, Kent BR2 6HL | www.kingswaygroup.co.uk

The anti-ligature design characteristics of this product are not intended to replace or substitute the need for necessary supervision of those who may be at risk, or for other necessary protective measures to be taken in the specific circumstances of usage. Kingsway Enterprises (UK) Ltd does not offer any products for sale as being 'ligature-free' and will not be liable for any claims arising from ligature attachment on its products. It is the customer's responsibility to ensure that products purchased and installed are suitable for the environments they are fitted in.