Page 1: Dual Compressor Centrifugal Chillers with …surplusgroup.com/wp-content/uploads/1949_SpecSheet.pdfDual Compressor Centrifugal Chillers ... Notes: 1. Condenser ... To facilitate compressor

Installation, Operating and Maintenance Manual IMM WMC

Group: Chiller Part Number: 330599801 Effective: November 2004

Supersedes: New

Dual Compressor Centrifugal Chillers with Magnetic Bearings

Model WMC-150, Cooling Only 50/60 Hertz R-134a

Page 2: Dual Compressor Centrifugal Chillers with …surplusgroup.com/wp-content/uploads/1949_SpecSheet.pdfDual Compressor Centrifugal Chillers ... Notes: 1. Condenser ... To facilitate compressor

IMM WMC Centrifugal Chillers 3

Introduction

General Description The McQuay Model WMC Centrifugal Water Chiller is a complete, self-contained, automatically controlled, fluid-chilling unit featuring dual, oil-free, magnetic bearing compressors. Each unit is completely assembled and factory tested before shipment. The WMC chillers are equipped with two compressors operating in parallel with a single evaporator and single condenser. The chillers use refrigerant R-134a that operates at a positive pressure over the entire operation range, so no purge system is required. The controls are pre-wired, adjusted and tested. Only normal field connections such as water piping, relief valve piping, electric power and control interlocks are required, thereby simplifying installation and increasing reliability. Necessary equipment protection and operating controls are included. All McQuay centrifugal chillers are factory-tested prior to shipment and must be commissioned by a factory-trained McQuay service technician. Failure to follow this startup procedure can affect the equipment warranty. The standard limited warranty on this equipment covers parts that prove defective in material or workmanship. Specific details of this warranty can be found in the warranty statement furnished with the equipment. Cooling towers used with McQuay centrifugal chillers are normally selected for condenser water inlet water temperatures between 75°F and 90°F (24°C and 32°C). Lower entering water temperatures are desirable from the standpoint of energy reduction, but a minimum does exist. For recommendations on optimum entering water temperature and cooling tower fan control, consult the “Condenser Water” section on page 27.

Nomenclature

W M C

W = Water-cooled

M = Magnetic Bearings

Centrifugal Compressor

Page 3: Dual Compressor Centrifugal Chillers with …surplusgroup.com/wp-content/uploads/1949_SpecSheet.pdfDual Compressor Centrifugal Chillers ... Notes: 1. Condenser ... To facilitate compressor

4 Centrifugal Chillers IMM WMC

Installation

Receiving and Handling The unit should be inspected immediately after receipt for possible damage. All McQuay centrifugal water chillers are shipped FOB factory and all claims for handling and shipping damage are the responsibility of the consignee. On units with factory-installed insulation, the insulation is removed from the vessel lifting hole (also used for transportation tie-downs) locations and are shipped loose. They should be glued in place after the unit is finally placed. Neoprene vibration pads are also shipped loose. Check that these items have been delivered with the unit. They are usually placed in a control panel. If so equipped, leave the shipping skid in place until the unit is in its final position. This will aid in handling the equipment. Extreme care must be used when rigging the unit to prevent damage to the control panels and refrigerant piping. See the certified dimension drawings included in the job submittal for the center of gravity of the unit. If the drawings are not available, consult the local McQuay sales office for assistance. The unit can be lifted by fastening the rigging hooks to the four corners of the unit where the rigging eyes are located (see Figure 1). Spreader bars must be used between the rigging lines to prevent damage to the control panels, piping and electrical panels.

Figure 1, WMC Major Component Locations NOTE: A small number of early prototypes have the control panel and OITS on the opposite side.

Compressor #2 Control Panel

Operator Interface Touch Screen (OITS) Rigging Holes

Each Corner

Evaporator

Condenser

Condenser Relief Valves

Evaporator Relief Valve

CombinedDischarge Check

and Shutoff Valve

Circuit #1 Power Panel

Circuit #2 Power Panel

Optional Single-Point Power Block or Disconnect Switch

Inlet

Outlet

Outlet

Compressor #1

Electronic Expansion Valve

Suction Shutoff Valve

Page 4: Dual Compressor Centrifugal Chillers with …surplusgroup.com/wp-content/uploads/1949_SpecSheet.pdfDual Compressor Centrifugal Chillers ... Notes: 1. Condenser ... To facilitate compressor

8 Centrifugal Chillers IMM WMC

Physical Data and Weights Evaporator Refrigerant-side design pressure is 200 psi (1380 kPa). Water-side is 150 psi (1034 kPa). In the event insulation is to be field-installed, none of the cold surfaces identified above will be factory insulated. Approximate total square footage of insulation surface required for individual packaged chillers is tabulated by evaporator code and can be found below.

Table 1, Evaporator Physical Data

Evaporator Code

Maximum Refrigerant Charge

lb. (kg)

Evaporator Water

Capacity, gal (L)

Insulation Area

sq. ft. (m2)

Vessel Weight lb. (kg)

Number of Relief Valves

E2209 590 (268) 38 (145) 66 (6.1) 2387 (1083) 1 E2212 790 (358) 45 (170) 90 (8.3) 2877 (1305) 1

Notes: 1. Refrigerant charge is for the entire unit and is approximate since the actual charge will depend on other variables.

Actual charge will be shown on the unit nameplate. 2. Water capacity is based on standard tube configuration and standard dished heads.

Condenser With positive pressure systems, the pressure variance with temperature is always predictable, and the vessel design and pressure relief protection are based upon pure refrigerant characteristics. R-134a requires ASME vessel design, inspection and testing and uses spring-loaded pressure relief valves. When an over pressure condition occurs, spring-loaded relief valves purge only that refrigerant required to reduce system pressure to their set pressure, and then close. Refrigerant-side design pressure is 200 psi (1380 kPa). Water-side design is 150 psi (1034 kPa).

Table 2, Condenser Physical Data

Condenser Code

Maximum Pumpdown

Capacity lb. (kg)

Water Capacity gal. (L)

Vessel Weight lb. (kg)

Number of Relief Valves

C2009 728 (330) 47 (147) 2130 (965) 2

C2012 971 (440) 62 (236) 2528 (1147) 2

Notes: 1. Condenser pumpdown capacity based on 90% full at 90°F. 2. Water capacity based on standard configuration and standard heads and can be less with lower tube counts. 3. See Relief Valves section for additional information.

Pumpdown To facilitate compressor service, all McQuay centrifugal chillers are designed to permit pumpdown and isolation of the entire refrigerant charge in the unit’s condenser. Model WMC chillers are equipped with suction and discharge shutoff valves and the refrigerant charge can also be pumped down into the evaporator.

Page 5: Dual Compressor Centrifugal Chillers with …surplusgroup.com/wp-content/uploads/1949_SpecSheet.pdfDual Compressor Centrifugal Chillers ... Notes: 1. Condenser ... To facilitate compressor

IMM WMC Centrifugal Chillers 9

Dimensions Figure 3, Dimension Drawing WMC 2 Pass Evaporator, 2 Pass Condenser

330654401 R01 Production Unit

“B”

20.4(518.2)

42.7(1084.6)

9.1 (231.1)

1.4 (35.5)5.2 (132.1) “C” 5.2 (132.1)

8.0 (203.2)8.0 (203.2)

78.0(1981.2)

35.0(889.0)

4.0(101.6)

26.5(673.1)

8.0”QTY. 2

6.0”QTY. 2

0 1.13QTY. 83.7 (93.9) “A” 31.2

(792.5)

6.9(175.3)

18.2(462.3)

12.6(320.0)

39.3(998.2)

26.5(673.1)

13.2 (335.3)19.2 (487.7)

Evaporator

Condenser

Inlet

Outlet

Out

In

1.0” FPTRelief Valves

NOTES: 1. The dimension drawing above is for standard production units. Certain early production units will have a different control panel

arrangement and a greater height dimension.

2. Left-hand connections shown. Right-hand connections are available for either vessel.

Dimensions Inches (mm) WMC Unit A B C

9 Foot Shells 31.2 (792.4) 134.7 (3421.4) 100.1 (2542.5) 12 Foot Shells 43.7 (1109.9) 169.6 (4307.8) 134.9 (3426.5)