dry vacuum system product overview

2
© Air Techniques, Inc Copyright 2013 P/N H5245, Rev. D February 2019 Corporate Headquarters 1295 Walt Whitman Road | Melville, New York 11747- 3062, USA Phone: 1-800-247-8324 | Fax: 1-888-247-8481 www.airtechniques.com Delivered Components Dry Vacuum System TM CT20 Dual Continuum Tank Product Overview Fully Assembled CT20 Dual Continuum Tank Unit CT20 Dual Continuum Tank Accessory Pack, P/N H5243 CT20 Dual Continuum Tank Assembly Air Solenoid Tank Solenoid Top Washout Port Washout Solenoid Top Float Switch Bottom Float Switch Bottom Washout Port Rear View Front View Adjustable Leveling Feet (2 each side) See-Thru Check Valve MOJOVE Master Controller (MMC) Tank Drain Gate Valve 2-Inch Flexible Coupler to Connect Tank Inlet from Operatory Tank Outlet to Pump Bottom Tank Inlet Port Top Tank Outlet Port Tank Drain Check Valve Item Part No. Description Qty 1 H5302 Exhaust Vent Assembly 1 2 H5234 2” to 2” Flexible Coupling Connector 1 3 77243 Mojave Master Controller Line Cord 10 Feet, 18 GA., IEC X North America, Hospital Grade 1 4 61022 Hospital Receptacle Only TAG 1 5 30936 Plastic Screw Anchor, #10-12 X 1” 4 6 30295 #10 X 3/4, Type A, Plated Slot Pan Head Screw 4 7 56194 Connector Adapter, 1/2” MNPT X 3/8” PUSH 1 8 53202-1 Switch Assembly; Push Button, Panel Mount, GRN/YEL, 6V LED 1 9 51453 Urethane Tubing, 1/4” OD 5 Ft 10 19271 Poly Tubing, 3/8” OD 10 Ft 11 54509 Poly Tubing, 85A, 10MM OD, 6.5MM ID, TBLU: FW# A40108: 10 Ft 12 H5153 User’s Manual V3, V5, V7, 2V3, 2V3CT, 2V5, 2V5CT, 2V7, 3V5 & 4V5 1 13 9922-479 Cleanstream Cleaning Poster 1 10 13 12 11 6 7 8 9 2 1 3 4 5

Upload: others

Post on 28-Jan-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

© Air Techniques, Inc Copyright 2013 • P/N H5245, Rev. D • February 2019

Corporate Headquarters1295 Walt Whitman Road | Melville, New York 11747- 3062, USA

Phone: 1-800-247-8324 | Fax: 1-888-247-8481

www.air techniques.com

De l i ve red Componen t s

Dry Vacuum System

TM CT20 DualContinuum Tank

Product Overview

Fully Assembled CT20 Dual Continuum Tank Unit

CT20 Dual Continuum Tank Accessory Pack, P/N H5243

CT20 Dua l Con t inuum Tank As sembly

AirSolenoid

TankSolenoid

Top Washout

Port

WashoutSolenoid

Top FloatSwitch

Bottom Float Switch

Bottom Washout

Port

Rear ViewFront View

Adjustable Leveling Feet

(2 each side)

See-Thru Check Valve

MOJOVE Master Controller (MMC)

Tank Drain Gate Valve

2-Inch Flexible Couplerto Connect Tank Inlet

from Operatory

Tank Outlet to Pump

Bottom Tank Inlet Port

Top Tank Outlet Port

Tank Drain Check Valve

Item Part No. Description Qty

1 H5302 Exhaust Vent Assembly 1

2 H5234 2” to 2” Flexible Coupling Connector 1

3 77243Mojave Master Controller Line Cord 10 Feet, 18 GA., IEC X North America, Hospital Grade

1

4 61022 Hospital Receptacle Only TAG 1

5 30936 Plastic Screw Anchor, #10-12 X 1” 4

6 30295 #10 X 3/4, Type A, Plated Slot Pan Head Screw 4

7 56194 Connector Adapter, 1/2” MNPT X 3/8” PUSH 1

8 53202-1Switch Assembly; Push Button, Panel Mount, GRN/YEL, 6V LED

1

9 51453 Urethane Tubing, 1/4” OD 5 Ft

10 19271 Poly Tubing, 3/8” OD 10 Ft

11 54509Poly Tubing, 85A, 10MM OD,6.5MM ID, TBLU: FW# A40108:

10 Ft

12 H5153User’s Manual V3, V5, V7, 2V3,2V3CT, 2V5, 2V5CT, 2V7, 3V5 & 4V5

1

13 9922-479 Cleanstream Cleaning Poster 1

10

13

12

11

6

7

8

9

2

1

3

4

5

TOP FLOAT SWITCHBOTTOM FLOAT SWITCH

AIR SOLENOID

TANK SOLENOID

WASHOUT SOLENOID

GRN/YEL GROUND

WIRES

MMC WIRING CONNECTIONS FOR SOLENOID VALVES

YELBRNORN

BLAC

KW

HIT

EBL

ACK

ORN

YEL

RED

BRN

CAT 5 CABLECONNECTORS

FOR PUMPS

J15

J16

J17

J18

J13 J12 J10 J11

J2

J4

J6

J7

J8

J14

YELBRNORN

WHITEBLACK

To Bi Color SwitchConnect by wire color

REDRED

BLACKBLACK

BLACKBLACK

WH

ITE

REMOTE PANEL SWITCH

SAMPLE VACUUM PORT

(REF)

Important - Check Valve:For proper operation, the Check Valve must be installed with the flow arrow positioned on top and pointing towards the inlet port of the bottom tank.

So leno id E l e c t r i ca l Connec t i ons

Important - Gate Valve:For proper operation, make sure that the Gate Valve of the Tank Drain is set in the open position.

Closing the Gate Valve will stop all drainage from the tank.

Tank Drain Gate Valve

MOJAVE Plumbing & Electrical Connections

Refer to the User's Manual, P/N H5153, and Pre-Installation Guide, P/N H5187, as needed for information on the plumbing and electrical connections necessary to complete the CT20 tank installation.

MMCConnector

Function

J2 Main Water Panel SwitchOptional equipment install at site.

J4 Main Water SolenoidOptional equipment install at site.

J6Washout SolenoidConnected at factory.

J7 CT20 Tank SolenoidConnected at factory.

J8 CT20 Air SolenoidConnected at factory.

J14 Drain PumpOptional equipment install at site.

J10 Bottom Float SwitchConnected at factory.

J11Top Float SwitchConnected at factory.

J12 Remote Panel Switch #53202-1Install at site.J13

J15 Thru J18 10-foot CAT 5 Cable to each PumpConnect at site.

Connections between the control solenoids must be made for the automatic operation and maintenance of the CT20 tank. Refer to the illustration at right and make sure that the connections are correct between the connection points listed below.

CT20 Solenoid TubingAir/Vacuum Connections

Point A to B Connects the vacuum of the top and bottom tank sections via the Tank Solenoid.Point C to D

CT20 Solenoid Tubing Water Connections

Point E to E1 Connects the facility water source to the top and bottom tank Washout Ports via the Washout Solenoid.

Point E2 to F

Point E3 to G

Point H Facility water input

Vent Line Drip Leg

Make sure to install the Exhaust Vent Assembly to the bottom end of the facility vent line using items 1 & 11 of the CT20 Dual Tank Accessory Pack, P/N H5243.

So leno id Tub ing Connec t i ons

CT20 Tank Solenoid Tubing Connections

F

AirSolenoid

TankSolenoid

CExhaust to

Atmosphere

BA

Push to Connect for Facility

Water SourceE1

WashoutSolenoid

E3E

E2H

G

D