drugwipe saliva test

2
Remove the blue sample collector from the white test cassette. Replace sample collector onto test cassette. The sample collector must lock in place with an audible double click. Applying slight pressure, wipe surface (e.g. forehead, steering wheel) Remove protection cap and fill to mark with water. Dip detection zone gently into filled protection cap for 15 seconds, then remove. CAUTION: Do not immerse the white plastic body! DrugWipe ® Test for Sweat and Surfaces Place test on a horizontal surface for 10 minutes. Then evaluate test. Ignore results that show be- fore the 10 minutes are complete, or after more than 10 minutes. Wet sampling pads on collector Shake off any excess water. Do not touch sampling pad. 1 3 4 5 6 7 Sampling Sweat (forehead and neck at the hair line) Advise the test person to move his tongue around the bottom of the cheek 3 times. With the sample collector saliva is wiped from the tongue or interior cheeck. Remove the blue sample collector from the white test cassette. Place the blue sample collector back onto the white test cassette. Both sampling pads must connect with an audible double click. Hold the test cassette vertically, ampoule at the bottom. Squeeze your thumb thoroughly on the word PRESS in order to break the ampoule. Hold the test cassette with the broken ampule vertically for 10 to 15 seconds. DrugWipe ® Saliva Test PRESS Click! Click! 1 3 4 5 Move the cap back into starting position. Lay the test on a horizontal surface and commence timing. Read the test result after 8 minutes. Ignore test results before and after. Do not move the test during that time. 2 Check sampling pads for colour change from red to yellow. This indicates sufficient saliva collection. Sample collector Sampling pads Test cassette Read-out window Ampoule Sampling in Saliva (tongue, oral cavity – shake off any excess saliva) 2 Sampling pads Sample Collector Portection cap Read-out window Test cassette 15 seconds 3–8 minutes

Upload: others

Post on 25-Feb-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DrugWipe Saliva Test

Remove the blue sample collector from the white test cassette.

Replace sample collector onto test cassette. The sample collector must lock in place with an audible double click.

Applying slight pressure, wipe surface (e.g. forehead, steering wheel)

Remove protection cap and fill to mark with water.

Dip detection zone gently into filled protection cap for 15 seconds, then remove. CAUTION: Do not immerse the white plastic body!

DrugWipe® Test for Sweat and Surfaces

Place test on a horizontal surface for 10 minutes. Then evaluate test. Ignore results that show be-fore the 10 minutes are complete, or after more than 10 minutes.

Wet sampling pads on collector Shake off any excess water. Do not touch sampling pad.

1

3

4

5

6

7

Sampling Sweat (forehead and neck at the hair line)

Advise the test person to move his tongue around the bottom of the cheek 3 times. With the sample collector saliva is wiped from the tongue or interior cheeck.

Remove the blue sample collector from the white test cassette.

Place the blue sample collector back onto the white test cassette. Both sampling pads must connect with an audible double click.

Hold the test cassette vertically, ampoule at the bottom. Squeeze your thumb thoroughly on the word PRESS in order to break the ampoule. Hold the test cassette with the broken ampule vertically for 10 to 15 seconds.

DrugWipe® Saliva Test

PRESS

Click!Click!

13

4

5 Move the cap back into starting position. Lay the test on a horizontal surface and commence timing. Read the test result after 8 minutes. Ignore test results before and after. Do not move the test during that time.

2

Check sampling pads for colour change from red to yellow. This indicates sufficient saliva collection.Sample collector

Sampling pads

Test cassette

Read-out window

Ampoule

Sampling in Saliva (tongue, oral cavity – shake off any excess saliva)

2

Sampling pads

Sample Collector

Portection cap

Read-out window

Test cassette

15 seconds

3–8 minutes

Page 2: DrugWipe Saliva Test

no consumption of drugs (only red control lines

are visible)

cause: wrong handling or malfunction of test repeat

with new test

Tests successful

Cannabis

XTC/ Amphetamines

Cannabis, Cocaine, XTC/Amphetamines, Heroine/Opiates

Test failed

Cocaine

Heroine/Opiates

Test successful: positive on drug consumption

For detailed information please ask for manual.

Read out at 10 minutes (5 parameters test)

Test result Detection window for Cannabis ( THC) Reaction of pupils after consumption

Sampling Saliva (Mouth)

Sampling Sweat (forehead)

Sampling Urine

If onsite testing is positive: take a bloodtest ASAP!

If onsite testing is positive: take a bloodtest ASAP!

4-6 hrs.

Concentration

6-10 hrs.

Blood

Saliva

4-6 hrs.

Concentration

10-12 hrs.

Blood

Sweat

1 2

4-6 hrs.

Concentration

5-8 Days

Blood

Urine

Test results:

Saliva Blood

Saliva Blood

Saliva Blood

Lower detection limit Salivatimeframe

Test results:

Sweat Blood

Sweat Blood

Sweat Blood

Lower detection limit Sweattimeframe

Test results:

Urine Blood

Urine Blood

Urine Blood

Lower detection limit Sweat Urinetimeframe

Securetec Detektions-Systeme AGEugen-Sänger-Ring 1 • 85649 Brunnthal • GermanyT +49 89 203080-1651 • F +49 89 [email protected] • www.securetec.net© 2012 Securetec Detektions-Systeme AG • 70512-v02-EN-120425

Drug

Cannabis

Heroine/Opiates

Cocaine

XTC/Amphetamines

Size of pupils Reaction to light

normal to dilated normal to decelerated (reddened, glossy eyes)

narrowed hardly noticeable

dilated decelerated

dilated decelerated

5,5 mm 5,0 mm

4,5 mm

4,0 mm

3,5 mm

3,0 mm

2,5 mm

2,0 mm

1,5 mm

1,0 mm

6,0 mm

6,5 mm

7,0 mm

7,5 mm

8,0 mm

8,5 mm

9,0 mm

Her

oine

/Opi

ates

Ligh

t re

flex

is n

on e

xist

ent

Can

nabi

s

Coc

aine

/XTC

/Am

phet

amin

es

1 2

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL

CO

OP

CA AM/MET

CL CL CL