Drayton by Schneider Electric UK CA CE (Fig 1) Wireless 2-channel Programmable Thermostat Model: RF902 Consists of Thermostat RF90T and Receiver RF90D Technical Helpline Tel: 0333 7000 622 Website: www.draytoncontrols.co.uk Email: [email protected] User Guide 06490311001 Iss A Before Installation If you do not have the knowledge to install the thermostat safely then you must arrange for a competent electrician to install it for you. Wiring must conform to the current IEE regulations. Prior to commencing the installation you must ensure the mains supply is switched off. 1. Installing the Digistat Receiver 1a. Location of the receiver Location The Digistat Receiver should be mounted in a convenient position, close to the boiler or central heating system wiring centre. (Care should be taken not to mount the receiver in a position where it is surrounded by metal objects or mains voltage cable, as this may interfere with the radio signal). For the best performance install in an open space, at least 30cm distance from any metal objects including wall boxes and boiler housing. It is recommended that the receiver is mounted on the wall nearest the final location of the Digistat Thermostat room thermostat and not less than 30cm from the boiler side panel. Warning: Installing the receiver too close to the metal side panel or mains cables may interfere with the radio signal. Installation Guide 1b. Installation of the wallplate Fixing (minimum wallplate clearances shown below) i. Loosen the securing screws, remove the wallplate, and if surface wiring is to be used, snap out the cable entry strip on the bottom edge of the wallplate with a pair of pliers. ii. Fix the wallplate, terminals at the top, either direct onto the flat wall using wall plugs and no 6 x1” wood screws or on a flush-mounting single conduit box using M3.5 x 14 screws. 100 mm N L 1 2 3 4 (Fig 2) (Fig 3) 2. Wiring This product is double insulated and does not require an earth connection. The receiver should be wired to the combi boiler or central heating wiring using the correct type of cable or flex. The receiver should be wired in to replace hard-wired room or programmable thermostats shown on the system or boiler wiring diagrams. Always check other manufacturers’ instructions for compatibility. Relay Output 3. Replace the front cover of the receiver by locating the two latches at the top and then fasten the two screws at the bottom. As soon as the Digistat receiver has power it will be ready for automatic pairing with the Digistat RF Thermostat. Digistat 3rd Generation BOILER 30cm Min Preferred side of boiler The range may be affected by composition/density and number of walls between the Digistat thermostat and receiver Radio Signal Range: 30m Typically SCR

Upload: others

Post on 03-Jan-2022

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Drayton 1b. Fixing (minimum wallplate clearances s hown

Drayton by Schneider Electric

UK CA

CE

(Fig 1)

Wireless 2-channel Programmable Thermostat

Model: RF902Consists of Thermostat RF90T and Receiver RF90D

Technical Helpline Tel: 0333 7000 622 Website: www.draytoncontrols.co.uk Email: [email protected]

User Guide 06490311001 Iss A

Before InstallationIf you do not have the knowledge to install the thermostat safely then you must arrange for a competent electrician to install it for you. Wiring must conform to the current IEE regulations.

Prior to commencing the installation you must ensure the mains supply is switched off.

1. Installing the Digistat Receiver

1a. Location of the receiver

Location The Digistat Receiver should be mounted in a convenient

position, close to the boiler or central heating system wiring centre. (Care should be taken not to mount the receiver in a position where it is surrounded by metal objects or mains voltage cable, as this may interfere with the radio signal). For the best performance install in an open space, at least 30cm distance from any metal objects including wall boxes and boiler housing.

It is recommended that the receiver is mounted on the wall nearest the final location of the Digistat Thermostat room thermostat and not less than 30cm from the boiler side panel.Warning: Installing the receiver too close to the metal side panel or mains cables may interfere with the radio signal.

Installation Guide

1b. Installation of the wallplate

Fixing (minimum wallplate clearances shown below)i. Loosen the securing screws, remove the wallplate, and if

surface wiring is to be used, snap out the cable entry strip on the bottom edge of the wallplate with a pair of pliers.

ii. Fix the wallplate, terminals at the top, either direct onto theflat wall using wall plugs and no 6 x1” wood screws or on aflush-mounting single conduit box using M3.5 x 14 screws.

100 mm

N L 1 2 3 4

(Fig 2)

(Fig 3)

2. WiringThis product is double insulated and does not require anearth connection. The receiver should be wired to thecombi boiler or central heating wiring using the correcttype of cable or flex. The receiver should be wired in toreplace hard-wired room or programmable thermostatsshown on the system or boiler wiring diagrams. Alwayscheck other manufacturers’ instructions for compatibility.

Relay Output

3. Replace the front cover of the receiver by locating the twolatches at the top and then fasten the two screws at thebottom. As soon as the Digistat receiver has power it will beready for automatic pairing with the Digistat RF Thermostat.

Digistat3rd Generation

BOILER

30cm Min

Preferred side of boiler The range may be affected by composition/density and number of walls between the Digistat thermostatand receiver

Radio Signal Range:

30m Typically

SCR

Page 2: Drayton 1b. Fixing (minimum wallplate clearances s hown

(Fig 4)Note: Second channel can be used for hot water

or second heating channel

4. Automatic pairing4a. Heating and Hot Water: when the Digistat Receiver is powered

and the Digistat Thermostat has batteries inserted both will automatically pair. While this short process is ongoing the receiver LEDs will lash green/amber and the thermostat will display the word SCAN.When the receiver is detected by the thermostat, the thermostat will display the options for the 2 channels:CH = heating onlyPress + or - button to change todHW CH = heating and hot waterCon irm your selection with the O button.Once paired the left-hand receiver LED will be solid green and the thermostat display will show the words PAIR REC for 3 seconds, before displaying current time and temperature.

4b. Two heating channels: irstly pair the irst Digistat Thermostat as above selecting CH on the Thermostat. The second Digistat Thermostat (part number RF90T supplied separately) is paired by pressing and holding the left-hand button on the receiver for 3 seconds and then inserting batteries in the new Thermostat. The Thermostat will display the word SCAN and the Receiver LEDs will lash green/amber. Once paired the right-hand receiver LED will be solid green and the thermostat display will show the words PAIR REC for 3 seconds, before displaying current time and temperature.

(Fig 5) (Fig 6)

5. 6.

The Digistat is now installed and will automatically start to control room/water temperatures.To swap between Heating and Hot Water on the thermostat press the button to open this option.Flashing radiator icon on the display = heatingUse + or - button to change to hot water ( lashing tap icon) Select with the O buttonIn either mode the radiator or tap icon will be displayed

Installation and Quick Start Guide 06490311001 Iss A

To make changes to the default Installer Options shown below, enter the Installer Options menu by pressing the settings button for 3 seconds. This allows access to the User Menu 01, the Advanced User Settings Menu 02, the Installer Settings 03, and Service Interval Settings 04. Use the + and - buttons to scroll to Installer Options and press O to select. You can exit the menu by pressing until you have returned to the home screen. In the Installer Options menu (Fig 8), scroll through the options using the + and - buttons and press O to select. Scroll through the different settings using the + and - buttons and press O to select and save. (Fig 9 shows Option 02 OFF).

(Fig 8) (Fig 9)

(Option 01) Partial Sight AssistantWhen enabled, audible tones indicate when the setpoint is more than, less than or equal to the current room temperature when a user manually adjusts the setpoint using the + button: Setpoint > room temperature - single high tone per 0.5°C increase Setpoint = room temperature - double tone Setpoint < room temperature - single low tone per 0.5°C decrease

(Option 02) Frost ProtectionThe Digistat will switch on the heating if the temperature falls to 5°C and maintains a temperature of 7°C even when in OFF mode.

(Option 03) Minimum Setpoint LimitChange minimum setpoint temperature. After any changes to setpoint limits, all setpoints in AUTO, MANUAL, BOOST and HOLIDAY modes will be modified to conform accordingly.

(Option 04) Maximum Setpoint LimitChange maximum setpoint temperature. After any changes to setpoint limits, all setpoints in AUTO, MANUAL, BOOST and HOLIDAY modes will be modified to conform accordingly.

(Option 05) Optimum StartWhen enabled, this uses current ambient temperature, the next scheduled setpoint and heat gain data captured by the device to adjust the thermostat setpoint early, so the ambient temperature is at the required level when the next event starts.

Delayed StartWhen enabled, this uses current ambient temperature, current event setpoint and heating characteristics of the environment to delay implementation of the setpoint if the ambient temperature is already close to it, therefore saving energy.

(Option 06) Valve Protection TimeIn some hydronic heating systems it may be required to protect the valve by operating it for a given time. When enabled, this maintenance feature ensures that each relay output is operated for at least one (1) minute each week.

INSTALLER OPTIONS

Page 3: Drayton 1b. Fixing (minimum wallplate clearances s hown

(Option 07) Sensor Fault FunctionIn the event of a sensor fault, central heating output is reduced to 30% by turning heating ON for 3 minutes, then OFF for 7 minutes.(Option 08) Application TypeSelect the central heating system energy type.(Option 09) System CapabilitySelect the flow capability of the heating system.(Option 13) Installer Settings LockWhen enabled, installers can lock the installer settings menu until a 3 digit code is entered. If the code is forgotten while device is locked, please call the Technical Helpline.(Option 20) Reset (Service Interval settings are NOT reset) Reset the Digistat to its original factory settings.Note that resetting a thermostat will lose the pairing with the receiver. The receiver (and additional thermostat if used) will also need to be reset before attempting to pair again. To reset the receiver press the left-hand receiver button for 15 seconds until the LEDs flash green/amber.(Si Option 01) Si StatusEnable or disable Service Interval Mode.(Si Option 02) Si TypeSelect effect imposed on the heating when service is due.(Si Option 03) Service Due DateSet date when next service is due.(Si Option 04) WarningSelect no. of days before service due date.(Si Option 05) Service Due AlarmEnable or disable the audible service due alarm.(Si Option 06) Si BoostEnable or disable the Service Boost feature (5 boosts).(Si Option 07) Password ResetChange the 4 digit PIN. If you forget your Si password, please call the Technical Helpline.

What is it Select between Default

Inst

alle

r Opt

ions

01 OFF ON ON02

Partial Sight Assistant Frost Protection ON OFF ON

03 5 High Limit 5

04 Low Limit 30 30

05

Low Set Point C High Set Point C Optimum Start OFF Delayed Start Optimum Start OFF

06 OFF 5 4 3 2 1 OFF

07 OFF ON OFF08 Gas Electric Oil Heat Pump Gas09 Fast Flow Normal/Slow Flow Fast Flow13 OFF ON OFF20

Valve Protection Time (Mins) Sensor Fault Function Application TypeSystem CapabilityInstaller Settings Lock Reset NO YES NO

Serv

ice In

tern

al O

ptio

ns

01 Si Status OFF ON OFF02 Si Type Reduced Comfort Heating OFF No Effect Reduced Comfort03 Si Due Date YY/MM/DD04 Si Warning 0 99 3005 Si Due Alarm OFF ON OFF06 Si Boost OFF ON OFF07 Si Password Reset Select 4-digit PIN 0000

Technical Data

Power supply 230VAC +/-10%, 50Hz

Switch type & rating 3(1)A 230V/50Hz

Min. recommended current

SPDT 10mA@24VAC (inductive)

Ambient temperature (receiver)

Operating 0°C to 45°C Storage - 20°C to 65°C

Ambient temperature (thermostat)

Operating 0°C to 40°C Storage - 20°C to 65°C

Ambient humidity (non condensing)

20% to 80%, 90% non-condensing

Temperature range 5°C to 30°C

Rated impulse voltage 4KV

Ball pressure test 75°C

Disconnection means 1B

Automatic action 100,000 cycles

Operating Frequency 2402-2480 MHz

Radio Frequency 433.92 MHz

Max RF Power transmitted (Bluetooth) +10dBm

Pollution situation Degree 2

Protection level IP30

WiringDesigned for fixed wiring only, to comply with IEE wiring regulations

Energy Class IV = 2%

Relevant EC Directives: 2014/53/EU (RED) 2011/65/EU (RoHS) 2012/19/EU (WEEE)

Standards: EN 60730-1 EN 60730-2-7 EN 60730-2-9 ESTI EN 300 328 ESTI EN 301 489 EN 50581 EN 15500

INSTALLER OPTIONS - continued

Page 4: Drayton 1b. Fixing (minimum wallplate clearances s hown

The Drayton Digistat thermostat is a universal thermostat with 24 hour, 5-2day or 7day program types and up to 8 time/temperature events per day and can also be used as a simple room thermostat.

Clock SettingYour Digistat is fitted with a “real-time clock”, which is pre-set at the factory; you will not have to alter the time settings. A special feature of this real-time clock is it will automatically change over during the GMT/BST summer/winter change-over, removing the need to manually alter the clock at these times.

General OperationProgrammable thermostats do not have “On” and “Off” times like traditional timers. They offer temperature control both day and night and you simply select which temperatures you require at each point in the day.

With the unit in “Auto Mode” (the calendar icon is visible at the bottom of the screen) the temperature can be changed for a short time by using the + and – buttons. Changing the temperature in this way will keep the Digistat set to your new temperature until the next pre-programmed event (at which time it will revert to programmed temperature). The temperature you are setting will flash on the screen. Once temperature is set, the unit will revert to showing the room temperature again. The indicator will show on the screen if the unit is calling for heat.

Programming the DigistatYour Digistat comes with the following settings pre-programmed for your convenience and is suitable for those working out of the house during a typical 9-5 pattern. When the 5-2day program type is selected the pre-set temperatures will be different Mon-Fri and Sat-Sun, as per the tables below:

Pre-set Program 1 (24h, 5-2day weekdays, or 7day):

Pre-set Program 1 (5-2day weekend):

Event 1 2 3 4 (5)* (6) (7) (8)

Time 06:30 08:30 16:30 22:30

Temperature 20°C 16°C 21°C OFF

Event 1 2 3 4 (5)* (6) (7) (8)

Time 07:00 09:00 16:00 23:00

Temperature 20°C 18°C 21°C OFF

Hereby, Schneider Electric Controls UK Ltd, declares that Digistat RF902 is in compliance with Directive 2014/53/EU. The declaration of conformity may be consulted at www.draytoncontrols.co.uk

*To add these additional time periods manually (max. 8 per day)please refer to the steps to the right.

The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Schneider Electric is under license. Other trademarks and trade names are those of their respective owners.

Setting up Times/Temperatures on the Digistat

1. With the product operating as normalin Auto Mode, press once. Use +and – to select the day or set of daysyou want to adjust the times andtemperatures for. Press O to confirm.

2. The time on the display will now beflashing as shown, use + and – toadjust the first period start time. PressO to confirm.

3. Once the time has been set thetemperature on the display will nowbe flashing, use + and – to adjust thetemperature for the first time period.Press O to confirm.

4. Move to the next time and temperatureperiods and adjust as needed,confirming the changes by pressing O.The new schedule will be savedpressing O when the word SAvE isflashing.

5. In Pre-set Program 1 you will have 4time periods available, to add more(max. 8 per day) press + when you seethe SAVE option on-screen and timeperiod 5 at the bottom of the screen,to scroll to the Add option. Press O toadd time period then adjust time andtemperature as required.

6. To exit press to go back untilyou return to the home screen.

All done!You have completed the quick start and the unit is now set correctly to follow your required timings. For further user information surrounding the thermostat and the app control please use the website where you can download full user instructions.