drawing must be viewed in adobe acrobat to enable … · 2.soprema nor its employees are designer...
TRANSCRIPT
PROJECT:
TITLE:
DRAWN BY: SOPREMA TECHNICAL SUPPORT, GGALLOWAY
NO.: DATE:REVISION:
DATE: 2.19.2020
SCALE: NTS
DRAWING NUMBER:
US.FP.04.011 FASTENER PER 4 FT²,
4X8 BOARD FASTENING PATTERN
USAGE OF THIS DETAIL IS GOVERNED BY THE TERMS OF SERVICE FOR SOPREMA DETAILS.PLEASE CONSULT THESE TERMS OF SERVICE PRIOR TO UTILIZING THIS DRAWING.
US CORPORATE ADDRESS310 QUADRAL DRIVE
WADSWORTH, OHIO 44281www.soprema.usTel:330.334.0066
1'
2'-6"
4'
6"
2'
1 PER 4 FT² FASTENING PATTERN
· ACTUAL ONE (1) FASTENER PER 4 SQUARE FEET
· EIGHT (8) FASTENERS PER BOARD
· ENSURE FASTENER ENGAGES THE TOP FLANGE FOR
STEEL DECK APPLICATIONS
8'
4'
SOPRAFIX 3IN STRESS PLATE
NOTES:
1. SOPREMA DETAIL DRAWINGS: REFER TO SOPREMA AND OTHER RELATED PUBLISHED DOCUMENTATION, PRODUCT DATA SHEETS (PDS) AND SAFETY DATA
SHEETS (SDS) FOR ADDITIONAL INFORMATION. ALL DETAIL DRAWINGS AND RELATED INSTALLATION GUIDELINES ARE PROVIDED BY SOPREMA FOR THE SOLE
PURPOSE OF ISSUING A SOPREMA WARRANTY. ACCORDINGLY, THE DETAIL DRAWINGS ARE NOT OFFERED, AND SHOULD NOT BE CONSIDERED, AS A
SUBSTITUTE FOR PROFESSIONAL DESIGN SERVICES.
2. SOPREMA NOR ITS EMPLOYEES ARE DESIGNER OF RECORD FOR ANY PROJECT. FASTENING PATTERNS PROVIDED BY SOPREMA ARE FOR SOPREMA
WARRANTY PURPOSES ONLY. REFER TO LOCAL BUILDING CODES, DESIGNER OF RECORD DOCUMENTS, AND JURISDICTIONAL/AGENCY APPROVALS FOR
PROJECT-SPECIFIC FASTENING REQUIREMENTS.
3. ROOF ZONE GUIDELINES PROVIDED HEREIN ARE OFFERED FOR REFERENCE. REFER TO ASCE/SEI 7 FOR SPECIFIC REQUIREMENTS.
TWIN LOC-NAILTRUFAST
®
VERSA-FAST
®
isoweld
®
STRESS PLATE
DRAWING MUST BE VIEWED IN ADOBE ACROBAT TO ENABLE CUSTOM LAYERING
METAL CAP NAIL
0.2(h)
0.6(h)
0.6(h)
0.2(h)
0.6(h)
0.6
(h)
33
3
3
2
2
1
1
1'
h = eave height a = 10% of least horizontal roof
dimension, but not less than 3ft
3
3 3
3
33
33
2 1
2
2
22
2
2
2
ROOF HEIGHT GREATER THAN 60ft
ROOF HEIGHT LESS THAN
OR EQUAL TO 60ft
a = 10% of least horizontal dimension
or 40% of eave height, whichever is
smaller, but not less than either 4% of
least horizontal dimension or 3ft
a
2a
a
a
a
1
FASTENING PATTERN FOR SHADED AREASFASTENING PATTERN FOR SHADED AREASFASTENING PATTERN FOR SHADED AREASFASTENING PATTERN FOR SHADED AREASFASTENING PATTERN FOR SHADED AREASFASTENING PATTERN FOR SHADED AREASFASTENING PATTERN FOR SHADED AREAS
ASCE 7-16 ROOF ZONES
(LOW-SLOPE ROOFS θ ≤ 7°)
ASCE 7-05/7-10 ROOF ZONES
(LOW-SLOPE ROOFS θ ≤ 7°)
ROOF HEIGHT GREATER THAN 60ft
ROOF HEIGHT LESS THAN
OR EQUAL TO 60ft
a = 10% of least horizontal roof
dimension, but not less than 3ft
3
3 3
3
2 1
2
2
2
a
2a
a
FASTENING PATTERN FOR SHADED AREASFASTENING PATTERN FOR SHADED AREASFASTENING PATTERN FOR SHADED AREASFASTENING PATTERN FOR SHADED AREASFASTENING PATTERN FOR SHADED AREASFASTENING PATTERN FOR SHADED AREAS
WI L L I A M GR A N T GA L L OWA Y