dr1000 brochure j2 sensing

12
1| Page cccc DR1000 Flying Laboratory, Drone Environmental Monitoring

Upload: others

Post on 05-Oct-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

1|P a g e

cccc

DR1000FlyingLaboratory,DroneEnvironmentalMonitoring

2|P a g e

MissionStatement

The Scentroid DR1000 is a fully capable flying laboratory, used to sample and analyze ambient air at heights of up to 150 meters above ground. Air quality mapping, model verification, analysis of potentially dangerous sites are all made possible by this novel innovation.

LiveChemicalMonitoring

The Scentroid DR1000 flying laboratory provides continuous monitoring of multiple chemicals. While in flight, five built-in chemical sensors can provide remote monitoring of chemicals selected at the time of ordering. Chemical monitoring can be provided for H2S, CH4, CO2, SO2, VOCs, and close to 30 other selected chemicals. Sensor readings along with GPS position and altitude can provide 3D mapping of ambient pollution and odour levels. This feature can also be used to guide the operator into a plume for bag sampling. See the table on page 11 for a list of the available sensors.

DR1000 can be equipped with up to 5 sensorsfromScentroidsensorlist.

*Checkoursensorlistonthelastpage

3|P a g e

ImprovesAirSamplingCapabilityoverDifficultTerrain&atDifferentHeights

It is often necessary to sample stacks, ponds, and other location where human access is difficult and /or dangerous. Furthermore, operator exposure to dangerous chemicals during sampling must be carefully considered. The Scentroid DR1000 flying laboratory allows the operator to stay safely away from potentially hazardous sources while acquiring live readings or air sample for laboratory analysis. The DR1000 can also be analyze and sample ambient air at an elevation of up to 150 meters above ground level that was previously impossible to accomplish.

4|P a g e

EndlessApplication

The DR1000 Flying laboratory provides a robust platform to conduct impact assessment and air quality measurement for a wide range of applications including monitoring of:

! Fugitive emission ! Flare emission ! Leak detection along oil pipe lines ! Landfill methane ! Odour emission ! And much more!

ThermalImaging

A thermal imaging camera can also be installed for visualconfirmation of fugitive emissions in a variety ofapplications such as landfills, storage tanks, and oil/gaspipes.

5|P a g e

RecommendedDrone

DR1000 is completely self-contained and requiresnothing from attached drone except as a vehicle.DR1000 can be attached to anyRotaryWingor FixedWings drone with payload capabilities of 3 kg. Anexampleofcommonly useddrones areDJI S1000andDJIMATRICE600.

DustMonitoring

The Scentroid DR1000 flying laboratory can also provide continuousmonitoring of PM 1, 2.5 and 10 using a laserscatteredparticulatecounter.Thedustmonitoringcanbeinstalledinadditiontothe5chemicalsensorsforcompleteambientairqualityassessment

6|P a g e

DirectFlarePlumeSampling

TheDR1000canbeflownintotheplumeofaflaretotakedirect samplesforanalysis forchemical compositionandolfactometry.Temperature andhumidityof theplumearealsomeasure toeasedispersioncalculationaswellas tokeepthedronesafe.

7|P a g e

Communication

DR1000will comewith simultaneous GPRS andWIFI communication capabilities. The GPRS is used to send data toScentroidcloudservercalledDroneInformationManagementSystem(DRIMS).Thesecureonlinesystemwillallowyoutoremotelymonitorandevencontroltheflyinglaboratoryaswellasstoreandprocessthedatacollected.TheDronealsoconnectstothegroundstationusingWIFIcommunicationprotocol.BothGroundstationandCloudbasedserversrunDRIMSsoftwareandsimultaneouslycanlogdatafrommultipleDR1000drones.

8|P a g e

GroundStation

TheGround station that is includedwith everyDR1000 Flying Laboratory consist ofa specialized laptopwith pre-installed Ubuntu and Windows 10 operating systems, high gain powerful communication antenna, and DRIMSsoftware. DRIMS (Drone InformationManagement Software) provides the user with means to control the flyinglaboratoryandlogallacquireddata.DRIMSwillprovidebothlivedataaswellasallhistoricaldataforallsensorsplusGPSposition,altitude,temperature,andhumidity.Theusercanalsocommandthedronewhentotakethesample,selectthesamplinginterval,adjustsamplingrate,andperformroutinemaintenancesuchascalibrationofsensors.Ifan optional on-board camera is selected the video feedwill also be sent to the ground station for simultaneousviewing.ThelaptopwillbedualbootandcanbeusedforotherworkincludingGISmapping,viewingflightpathonGoogleEarth,datapostprocessing,oranyothertask.

9|P a g e

Manufacturer Scentroid

Model ScentroidDR1000flyinglaboratory

Maximum operating time with full charge battery 2.5hours

Time to fill up a sample bag 5SecperLiter

Weight 3410g

Dimension 26cmx16cmx18cm

DR1000Specification

10|P a g e

# Sensor ID Type Chemical

Maximum Detection

Limit

Lowest Detection Threshold

Resolution (ppm) Cross sensitivity

1 CD1 NDIR CarbonDioxide-HighConcentration5%,20%and

100% 20ppm100,2000,10000

ppm NONE

2 CD2 NDIR CarbonDioxide-LowConcentration 5000ppm 0ppm 15ppm NONE

3 CO1 EC CarbonMonoxide(lowConcentration) 500ppm 15ppm 5ppm H2<10%

4 CO2 EC CarbonMonoxide(highconcentration) 10000ppm 250ppm 20ppm H2<10%

5 C11 EC Chlorine 20ppm 200ppb 20ppb H2S,NO2

6 E1 EC EthyleneOxide 100ppm 1ppm 0.1ppm H2S,NO,C2H4

7 H1 EC Hydrogen 5000ppm 1ppm 0.8ppm C2H4

8 HCL1 EC HydrogenChloride 100ppm 0.1ppm 0.1ppm H2S,NO2,CL2

9 HCY1 EC HydrogenCyanide 100ppm 0.1ppm 0.1ppm H2S,NO2

10 AM1 EC Ammonia 100ppm 0.5ppm 0.3ppm H2S,NO2,CL2

11 ON1 EC OxidizingGasesOzoneandNitrogenDioxideO3-20;NO2-

20ppm 20ppb 15ppb H2S,CL2

12 PH1 EC Phosphine(lowConcentration) 10ppm 50ppb 30ppb H2S,C2H4,

13 PH2 EC Phosphine(highConcentration) 2000ppm 5ppm 2ppm H2S,C2H4,

14 HS1 EC HydrogenSulfide(lowConc-ppb) 1ppm 3ppb 1ppb CL2<20%

15 HS2 EC HydrogenSulfide(highConc-ppm) 2000ppm 1ppm 1ppm CL2<20%

16 E2 MOS Organicsolvents(Ethanol,Iso-Butane,H2) 500ppm 0ppm 1ppm Benzines<20%

17 MT1 NDIR Methane(LEL) 100%LEL(50,000ppm)

500ppm 200ppm Methane,propane,

18 NC1 EC NitricOxide-NO-(lowConcentration) 20ppm 15ppm 5ppb None

19 NC2 EC NitricOxide-NO(HighConcentration) 5000ppm 2ppm 1ppm None

20 ND1 EC NitrogenDioxide(LowConcentration) 20ppm 0.03ppm 0.02ppm H2S,CL2,

21 ND2 EC NitrogenDioxide(highConcentration) 200ppm 0.3ppm 0.1ppm H2S,CL2,

22 O1 EC Oxygen 20% 0.01% 0.01% NONE

23 O2 EC Oxygen 100% 0.20% 0.10% NONE

24 PD1 PID TotalVOCs(ppb)-PID50ppm(

isobutylene) 0ppm1(ppb

isobutylene) AllVOCs

25 PD2 PID TotalVOCs(ppm)-PID 300ppm(isobutylene)

1ppm 0.1(ppmisobutylene)

AllVOCs

26 SD1 EC SulfurDioxide(highConcentration) 2000ppm 0.5ppm 0.5ppm NO2,CL2

27 SD2 EC SulfurDioxide(lowConcentration) 20ppm 10ppb 5ppb NO2,CL2

28 FM1 EC Formaldehyde 10ppm 0.01ppm 0.01ppm Ethanol

29 PM1-10

LaserScattered ParticulatePM1,2.5,10(simultaneous) 10,000

Particles/Sec PM1 N/A NA

30 MS1 MOS GeneralPurposeOdours(VOCs)1000ppmisobutanol 0.5 0.5 VOCsandSolvents

31 MS2 MOS TRSandAmines3ppm(Methyl

Mercaptan)10ppb 10ppb

TrimethalAmine,MethylMercaptans,H2S,other

aminesandsulfurcompounds

32 MS3 MOS AirContaminants(ammonia,Ethanol, 3ppm 10ppb 10ppb (ammonia,Ethanol,Toulene)

SensorList

11|P a g e

Toulene) (ammonia)

33 MS4 MOS Ammonia 300 10 0.5 Ammonia,H2S,Ethanol

12|P a g e

SCENTROiD

DivisionofIDES[Grabyourreader’sattentionwithagreatquotefromthedocumentoruse

thisspacetoemphasizeakeypoint.Toplacethistextboxanywhereonthepage,justdragit.]

CANADA

Scentroid 431 Alden Road#3 Markham, ON, L3R 4C1 Contact us +1 416.479.0078 Web and Email Email: [email protected] www.scentroid.com

[email protected]

Wamelseweg 2A/2B

6626 KP Alphen (gld)

j2sensing.nl j2sensing.com

+31 (0)487 503 096