![Page 1: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/1.jpg)
Working Through Mistakes, Miscues, and Mishaps in Actinide Separations
Shane KnockemusUS EPA / NARELMontgomery, ALMay 4, 2004
![Page 2: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/2.jpg)
Goal
To give some examples of laboratory goof ups that I have been victim of, and how to salvage a successful analysis without having to rerun the sample from square one.My examples include using the wrong strip solutions, omitting important oxidation/reduction steps, and arranging the cartridges in the wrong order.
![Page 3: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/3.jpg)
TEVA / TRU separation scheme
TEVA
(Th)
TRU
(Am,Pu,U)
1 2 3
123
1 2 3 (Discard)
1 Load solution: 2.5 M HNO3/ 0.5 Al(NO3)3,
ferrous sulfamate, ascorbic acid. Elements are loaded in the following valence states: Am+3, Pu+3, Th+4, U+6, (Np+4).
2 Rinse: 2.5 M HNO3, ferrous sulfamate.
3 Rinse: 2.5 M HNO3.
Separation Scheme (part 1)Separation Scheme (part 1)
TEVA
(Th)
12 3
(Discard) 1
2 3Th
1. Rinse: 2.5 M HNO3
2. 9 M HCl3. 6 M HCl
TRU
2 3
1
4
5
(Discard) 1
2 3Am
5
U4
Pu
1. Rinse: 2.5 M HNO3
2.5 M/ 0.1 M NaNO2
2.5 M HNO3
2. 9 M HCl3. 4 M HCl
4. 0.1 M HCl/ 0.1 M H2C2O4
5. 0.1 M (NH4)2C2O4
Separation Scheme (part 2,3)Separation Scheme (part 2,3)
![Page 4: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/4.jpg)
Goof up scenario #1
What went wrong?….I used the U strip solution (ammonium oxalate) to elute Pu fraction.Result: Pu and U were eluted together.Point of realization?How to salvage usable analyses….If the mistake is realized before it is too late the Pu. and U may be precipitated selectively.It may also be an option to precipitate Pu and U together if both were precipitated in the presence of TiCl3. Good resolution is a necessity.
![Page 5: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/5.jpg)
Selective Precipitation Scenario
Sol’n w/ Pu+4 and U+6
Nd+3, HF
filter---save filtrate
NdF3--Pu
Sol’n w/ U+6
reduce volume
Nd+3, TiCl3, HF
NdF3--U
![Page 6: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/6.jpg)
Clean Pu Spectrum
![Page 7: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/7.jpg)
Clean U Spectrum
Precipitating the U fraction from the filtrate of the Pu pptn can diminish the recovery slightly (10-20%), but results are still within acceptable ranges.
![Page 8: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/8.jpg)
Pu and U Together
With slightly improved resolution, which may be obtained by counting the sample on a lower shelf, Pu and U could possibly be determined simultaneously.
![Page 9: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/9.jpg)
Goof Up Scenario #2
What went wrong?…ferrous sulfamate was not added to load solution.Result: Pu will remain in the +4 valence, and will be retained and eluted with Th fraction from TEVA.Point of realization?…If the mistake is realized after the Th fraction has already been filtered and counted then the filter must be leached and/or wet ashed to do chemistry that will enable Pu / Th separation. If the mistake is realized prior to the precipitation and filtration of Th, but after the elution of Th (and Pu), the solution containing the Pu / Th mixture may be used for subsequent chemistry.
![Page 10: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/10.jpg)
Pu and Th Together
![Page 11: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/11.jpg)
Th / Pu Separation Scheme
Sol’n w/ Th and Pu
SO4-2, BaCl2
BaSO4 (Th, Pu)
EDTA
Ti+3, KOH
Ti(OH)3 -- (Th, Pu)
HClO4, water, Nd+3
KMnO4, HF
NdF3 – Th(save filtrate)
Filtrate w/ PuO2+2
HClO4, heat
Water, Fe+2, Nd+3, HF
NdF3 -- Pu
![Page 12: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/12.jpg)
Pu-less Th Spectrum
![Page 13: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/13.jpg)
Pu Spectrum
![Page 14: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/14.jpg)
Goof Up Scenario #3
What went wrong?….did not oxidize Pu to +4 valence prior to elution of Am from TRU.Result: Pu will remain in +3 valence, and will be eluted with Am fraction.Point of realization?…before or after precipitation.Subsequent chemistry involved in separating Am and Pu will be the same as the Th / Pu chemistry involved in “Goof up scenario #2”, whereas the Am will behave the same as Th.
![Page 15: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/15.jpg)
Pu and Am Together
![Page 16: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/16.jpg)
Pu-less Am Spectrum
![Page 17: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/17.jpg)
Pu Spectrum
![Page 18: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/18.jpg)
Goof Up Scenario #4
What went wrong?….cartridges set up in wrong order (TRU-TEVA rather than TEVA-TRU).Result: Everything retained on TRU.Point of realization?….at the time of disconnecting tandem arrangement.Subsequent chemistry involved in obtaining usable analyses involves a mixture of things already covered.
![Page 19: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/19.jpg)
Spectrum of Everything Retained on TRU
Everything stripped from TRU with 0.1 M ammonium oxalate
![Page 20: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/20.jpg)
How to Salvage Usable Analyses
Everything on TRU (Am+3, Pu+3, Th+4, U+6).Am eluted with 4 M HCl.Pu / Th eluted together with 1 M HCl / 0.1 M oxalic acid. Pu and Th separated by chemistry demonstrated in ‘Goof Up Scenario #2’.U eluted with 0.1 M ammonium oxalate.
![Page 21: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/21.jpg)
Spectra From Goof Up #4
![Page 22: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/22.jpg)
Super Goof Up Scenario
What went wrong?….cartridges were arranged in the wrong order, ferrous sulfamate reduction of Pu omitted, sodium nitrite oxidation of Pu omitted, and wrong stripping solutions were used.
![Page 23: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/23.jpg)
How To Fix Super Goof Up
Get out of the lab!Sober up.Consider a desk job.
![Page 24: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/24.jpg)
Problems Encountered
The behavior and stability of Pu at the +6 valence proved to be hard to predict at times.In scenario # 2, 3, and 4 getting Pu to maintain a +6 valence during the NdF3 precipitation of both Th and Am proved to be difficult and at times not complete.Don’t co-precipitate samples with CeF3 in the presence of a strong oxidizer, as it will oxidize the Ce to +4 valence and will render the fluoride precipitation impossible.
![Page 25: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/25.jpg)
Pu Contamination in Th Spectra
![Page 26: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/26.jpg)
Pu Contamination in Am Spectrum
![Page 27: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/27.jpg)
Acknowledgements
The chemistry involved in obtaining successful separations was borrowed / learned from David Sill and Steven Bohrer from RESL in Idaho Falls, ID.
![Page 28: Working Through Mistakes, Miscues, and Mishaps in Actinide Separations](https://reader035.vdocuments.site/reader035/viewer/2022062410/56815922550346895dc64bd0/html5/thumbnails/28.jpg)
Conclusions
Mistakes are inevitable as long as humans are involved.Don’t be too quick to dump a sample and start over when a mistake is made. Something can be learned from most mistakes.Successful separations are still quite possible in most situations when mistakes are made.