Transcript
Page 1: Unique Features Screw Chiller (Water Cooled Water Chiller) · (Water Cooled Water Chiller) Cooling Capacity from 30 TR to 200 TR ... integrated check valve, integrated pressure relief

Plot No. 147, 148 & 154, Devraj Industrial Park, Piplaj-Pirana Road, Piplaj, Ahmedabad - 382405, Gujarat, India

+91 79 2970 8147 | +91 97129 28201, +91 90990 76206

[email protected] | www.conairgroup.com/india

www.facebook.com/nuvuconair

Nu-Vu Conair Pvt. Ltd.

(An ISO 9001:2015 Certified Organization)

Joint Venture with The Conair Group, USA

A World Leader in Plastic Auxiliary Equipment Manufacturing

Screw Chiller

(Water Cooled Water Chiller)

Cooling Capacity from 30 TR to 200 TR Energy Efficient Central Chilling Plant.

Provide chilled fluid for industrial application from a central location with the Conair Water Cooled W-SK series central chillers.

Simple design of screw compressorsprovide both full load and part load efficiencies unmatched in the industry, and results in lower energy costs when compared to reciprocating compressors.

Screw Chiller (Water Cooled Water Chiller)

Option of eco friendly refrigerant (R134a) also availableHelical screw design results in part load performanceOnly four moving parts when compared to reciprocating compressors; there are no pistons, connecting rods, suction and discharge valves or mechanical oil pumpLatest heat transfer technology results in increased condenser and evaporator tube efficiencyReduced rotor clearance results in reduced leakage between the high and low pressure cavities during compressionResistant to liquid slugging; this compressor design can handle amounts of liquid refrigerant that would severely damage a reciprocating compressorDeveloped by Thermal Care � Group company of Conair Inc. USAUse of multiple Proportional Integral Derivative (PID) temperature control loops ensures consistent reliability, stability, and efficient operation by instantly reacting to fluctuations in system loadsFULL Screen Display � a simplified view of Chiller with larger display of SETPOINT and PROCESS temperatures that can be seen from a distance provides a quick glance to validate the operationClear language text display and graphic representation of unit components provides quick and easy understanding of unit operationControl on no. of ON / OFF cycle of compressor Controls and maintains stable and reliable operation of the chiller through use of an extensive array of sensors, actuators, relays, switches, and control algorithms User friendly screen for operatorCommon locations for most adjustment or settingsDetailed description for each settingProcess supply water above high temperature alarm set point Process supply water below low temperature alarm set point Status banner of start-up and shut-down sequences Compressor ON / OFF cycle control

Unique FeaturesRugged compressor design with only four moving parts eliminating the need for pistons, connecting rod, wrist pins and valves. Less moving parts means less internal friction and greater efficiencySemi hermitic screw compressors with two shaft designs with suction and discharge solder connection, integrated check valve, integrated pressure relief valves, flanged on oil separator, oil heater, oil filter and oil sight glassAll chilled water contact surfaces are non ferrous for protection against corrosion. All wetted surfaces are stainless steel, copper or other non ferrous materialSmall unit size, factory wired, easy lifting procedure, easy start up logicStainless Steel Brazed Plate Heat Evaporator with option of Shell & Tube Evaporator designed for high surface area and rapid response (capacity up to 60 TR)Shell & Tube Evaporator with option of Stainless Steel Brazed Plate Evaporator designed for high surface area and rapid response (capacity of 75 TR and above)Strainer protects the evaporator from solid contaminations in the process waterFlow switch is used to detect flow loss for safety of evaporator when return water flow is lowElectronic expansion valve is used to regulate the flow of refrigerant in the evaporator as per the load of system to maintain the suction superheatShell & Tube type water cooled condenser for Indian ambient condition with externally finned copper tubeRemovable cartridge type filter dryer to ensure moisture free system and quick change featuresSight glass indicates the status of dry or moist systemPressure switch protects the compressor against low and high pressureMonitoring of suction and discharge refrigerant pressuresAntifreeze protection to safe guard the evaporator & compressor against low temperature

358 (102)

1 / 65.8

102 / 170

R22

140

1650 - 1950

109.5

W100-SK-PT

414 (118)

1 / 88.8

132 / 216

R22

1850

165

1750 - 2050

139.5

W125-SK-PT

476 (135)

1 / 107

150 / 246

R22

11

1380

4.8

175

1850 - 2150

2750

161

W135-SK-PT

623 (177)

1 / 115.3

186 / 310

R22

225

2600 - 2800

201

W175-SK-PT

268 (76.2)

1 / 46.3

96 / 162

R134a

103.5

WE90-SK-PT (R134a)

283 (80.4)

1 / 52.9

96 / 155

R134a

1600

2.8

1200

125

1550 - 1800

103.5

WE100-SK-PT (R134a)

335 (95.27)

1 / 56.5

110 / 182

R134a

1750

3000

1770

4" FLANGE

6" FLANGE

117.5

WE125-SK-PT (R134a)

413 (117.4)

1 / 70.5

131 / 214

R134a

144

WE135-SK-PT (R134a)

504 (143.3)

1 / 86.1

155 / 280

R134a

15

2500

4

2000

2000

1000

1180

6� FLANGE

2400 - 2600

165

WE175-SK-PT (R134a)

* Nominal capacity based at leaving water temperature of 15°C & condenser water temperature of 30°C.** We can also provide pump & tank units suitable for above sizes of screw chillers.

All specifications are subject to change without prior notice.

788 (224)

1 / 139.5

175 / 291

R22

330

4154

4500

190

576 (163)

1 / 97.6

175 / 310

R134a

1870

3420

185

1850 - 2050

8" FLANGE

2750

678 (192)

1 / 110.5

167 / 306

22

3300

4.5

8" FLANGE

280

3532

4500

189

W250-SK-PTWE250-SK-PT

(R134a)WE300-SK-PT

(R134a)

259 (73.6)

1 / 47.5

88 / 144

R22

1460

2660

1400

1450

1320

1330

3" FLANGE

100

1300 - 1550

4 " F L ANGE

2100

95.5

W75-SK-PT

415V, 50 Hz, 3 Phase

24V DC

Plus (+) 8 to Plus (+) 25

Require treated water with PH value in between 7.5 to 8.5, hardness less than 50 PPM, electrical conductivity <10-30 µS/ cm²

Black RAL 9005 / Siemens Grey RAL 7032

Performance Characteristics

Nominal Capacity * KW (TR)

Compressor Quantity / KW

Max. Power Input KW / Max. Current Amp-Comp

Refrigerant

Standard Evaporator Pump / Process Pump KW

Maximum Flow to Evaporator / Process LPM

Maximum Pressure Bar

Water Reservoir Capacity Liters

Dimension W x D x H (mm) - Main Unit

W - Width

D - Depth

H - Height

Dimension W x D x H (mm) - Pump Unit

W - Width

D - Depth

H - Height

Process Connections

Process Connections Inlet / Outlet � BSP - Inch

Condenser Water Cooling Capacity Require TR

Condenser Water Flow Rate LPM

Condenser Water Inlet / Outlet – BSP - Inch

Weight Kg

Installed (NET)

Voltage

Connected Load KW

Control Voltage

Control Range in Degree Celsius

Utility

Color

Model

229 (65)

1 / 42.1

78 / 128

R22

90

900 - 950

85.5

W65-SK-PT

179 (51)

1 / 33.8

65 / 198

R134a

7.5

960

4.8

900

70

700 - 750

72.5

WE65-SK-PT (R134a)

Technical Specifications

130.9 (37.2)

1 / 24.7

65 / 105

R134a

5.5

500

1000

2700

2100

1320

1050

1150

2.5" FLANGE

1900

70.5

WE40-SK-PT (R134a)

W55-SK-PTWE55-SK-PT

(R134a)

153 (43)

1 / 33.3

52 / 86

R22

480

5.6

55

600 - 650

3" FLANGE

57.5

W40-SK-PT

191 (54)

1 / 38.4

65 / 108

R22

645

4.4

65

700 - 750

159 (46)

1 / 27.7

51 / 86

R134a

56.5

206 (58.5)

1 / 38.5

78 / 124

R134a

90

85.5

WE75-SK-PT (R134a)

316 (90)

1 / 57.6

96 / 162

R22

125

1550 - 1800

107

W90-SK-PT

Top Related