Transcript
Page 1: Typical data for SURA M250-35A - Cogent Power · RD represents the rolling direction TD represents the transverse direction Values for yield strength (0.2 % proof strength) and tensile

RD represents the rolling directionTD represents the transverse directionValues for yield strength (0.2 % proof strength)and tensile strength are given for the rolling directionValues for the transverse direction are approximately 5% higher June 2008

Typical data for SURA® M250-35A

Loss at 1.5 T , 50 Hz, W/kg 2,35Loss at 1.0 T , 50 Hz, W/kg 0,98Anisotropy of loss, % 10

Magnetic polarization at 50 HzH = 2500 A/m, T 1,53H = 5000 A/m, T 1,64H = 10000 A/m, T 1,76

Coercivity (DC), A/m 40Relative permeability at 1.5 T 660Resistivity, μΩcm 55

Yield strength, N/mm² 455Tensile strength, N/mm² 575Young’s modulus, RD, N/mm² 185 000Young’s modulus, TD, N/mm² 200 000Hardness HV5 (VPN) 215

T W/kg at 50 Hz

VA/kgat 50 Hz

A/mat 50 Hz

W/kg at 100 Hz

W/kgat 200 Hz

W/kg at 400 Hz

W/kgat 1000 Hz

W/kgat 2500 Hz

0,1 0,02 0,06 26,8 0,04 0,08 0,21 0,98 4,09

0,2 0,06 0,15 35,7 0,14 0,33 0,90 3,65 14,8

0,3 0,13 0,27 41,8 0,31 0,73 1,93 7,58 30,6

0,4 0,21 0,40 47,5 0,51 1,23 3,24 12,7 51,7

0,5 0,31 0,56 53,4 0,75 1,82 4,81 18,8 78,8

0,6 0,41 0,74 60,0 1,01 2,49 6,69 26,3 113

0,7 0,52 0,95 67,9 1,31 3,26 8,82 35,2 155

0,8 0,66 1,21 77,5 1,64 4,12 11,2 45,7 208

0,9 0,81 1,52 90,0 2,00 5,07 14,0 58,1 273

1,0 0,98 1,92 107 2,41 6,14 17,1 72,6 352

1,1 1,15 2,46 133 2,87 7,33 20,6 89,6

1,2 1,37 3,30 179 3,40 8,69 24,6

1,3 1,65 4,97 284 4,03 10,3 29,2

1,4 2,00 10,3 642 4,83 12,4 35,1

1,5 2,35 30,0 1810 5,72 14,7 41,6

1,6 2,65 75,7 4030

1,7 2,87 153 7290

1,8 3,06 267 11700