Ahead of Vision
PENTAX Industrial Instruments Co., Ltd.2-5-2 Higashi-OizumiNerima-Ku, Tokyo 178-8555, JapanTel. +81 3 5905 1222Fax +81 3 5905 1225E-mail: [email protected]: www.pentax.co.jp/piic/survey
www.pentaxsurveying.com
TOTAL STATION
V200QUICKREFERENCEGUIDEBASIC PROCEDURESPOWER TOPO EXPRESS
SERIES
PEN-V200-QUI-Cover 30-08-2006 14:13 Pagina 1
3
Quick Reference Guide Basic Procedures
for Total Station V-200 Series
V-227NV-227
The description concerning the reflectorless function in this guide is applied to V-227N.
PENTAX Industrial Instruments Co.,Ltd.
4
6666
CONTENTSGeneral
Instruction ManualsPrecautions regarding safetyWarningUsage Precautions 7
1 Basic Operation 81.1 Removing the Battery 81.2 Attaching the Battery 81.3 Turning the Power On and Off 91.4 Display and keyboard 91.4.1 Operation keys 91.4.2 Function keys 10
1.5 Angle Measurement 121.5.1 Horizontal Angle 121.5.2 Vertical Angle 12 1.6 Distance Measurement 131.6.1 Select your target 131.6.2 Distance Measurement 131.6.3 Changing Target constants 131.6.4 Input Temperature and Atmospheric
pressure14
1.6.5 Adjusting LCD contrast 141.6.6 Adjusting Illumination brightness 14 2 Changing Instrument Settings 152.1 Help menu 152.2 Instrument setting items 15 3 Warning and Error Messages 16 4 Specifications 17
Notice to the user of this product 19
5
PowerTopoExpress
5 Starting Special Function 246 Creating / Selecting a Job File 247 Input a Known Point Coordinate 258 Rectangular Coordinate Measurement 268.1 Station Point Setup 268.2 Orientation (Station Point H.Angle Setup) 278.3 Measurement 288.4 Offset Measurement 298.5 Remote measurement 309 Polar Coordinate Measurement 319.1 Station Point Setup 319.2 Orientation (Station Point H.Angle Setup) 329.3 Measurement 339.4 Offset measurement 3410 Free Stationing 3510.1 Known Point Setup 3510.2 Measuremen 3510.3 Calculation 3611 Stake Out 3611.1 Station Point Setup 3611.2 Orientation (Station Point H.Angle Setup) 3711.3 Stakeout Point Setup 3711.4 Stakeout Measurement 3712 Stake Out (Point to Line) 3912.1 Station Point Setup 3912.2 Orientation (Station Point H.Angle Setup) 3912.3 Point A Setup 4012.4 Point B Setup 4012.5 Point To Line Measurement 4113 INVERS 4214 Area Calculation 4215 REM 4316 RDM (Remote Distance Measurement) 44
Preference List 45
6
Instruction Manuals
Quick Reference Guide is intended to provide a quick reference in the field. For ease of use in the field, the following Quick Reference Guide booklets are provided in the carrying case.
1. Quick Reference Guide (Basic procedure) (Power Topo Express,Operating procedure)
The complete instruction manuals are contained on the CD that is attached to each V-200. This guide uses the symbol “ xN”as an expression of repeating times of key operation. For example. “ x2” means that [ESC] key is pressed two times. The symbol “+”expresses that multiple keys are pressed simultaneously.
Before using this product,be sure that you have thoroughly read and understood the instruction manual that is included in the attached CD-ROM to ensure proper operation.
Solar Observation Never view the sun directly using the telescope as this may result in loss of sight.
Laser Safety V-200 is a class-II (2) Laser product. Avoid direct eye exposure. Do not stare into laser beam.
Electro-Magnetic Compatibility (EMC) This instrument complies with the protection requirement for residential and commercial areas. If this instrument is used close to industrial areas or transmitters, the equipment can be influenced by electromagnetic fields.
RECAUTIONS REGARDING SAFETY
PWARNING
7
Risk of Explosion Do not use this product in a location where there is coal dust,or near flammable material as there is a risk of explosion.
Target Constant
Confirm the Target Constant of the instrument before measurement.
Reflectorless The reflectorless measurement range may vary depending on the target and surrounding brightness.
In case the reflectorless measurement results in low accuracy, perform the distance measurement by Prism. (V-227N)
Battery & Charger Use the battery charger that is suitable to the battery you are using. If water should happen to splash on the instrument or the battery, wipe it off immediately and allow it to dry in a dry location.
PUSAGE PRECAUTIONS
8
1. Basic Operation
1.1 Removing the Battery
(1) Rotate the knob above the battery pack counter-clockwise. (2) Lift up the battery pack and remove it from the instrument.
1.2 Attaching the Battery
(1) Place the channel on the bottom of the battery pack, onto the protrusion of the instrument and push the battery pack down into place.
(2) Turn the knob clockwise.
9
1.3 Turning the Power On and Off
To set power on : To shut down:
To turn the power supply off, press the I/O key for more than 1 second and then release it. Power turns OFF.
1.4 Display and keyboard
1.4.1 Operation keys
[ESC] Returns to previous screen or cancels an operation.
Turns the illumination of the LCD display and telescope reticle on and off.
Moves the cursor to the direction,respectively. The up or down increases or decreases the value,respectively.
[ENT] Accepts the selected (highlighted) choice or the displayed screen value.
[HELP] Pressing this key causes a help menu to appear in MODE A or MODE B or causes a help message to appear.
NOTE: The power is automatically turned off after 10 minutes of inactivity (Factory default setting).
10
1.4.2 Function keys
MODE A
[MEAS] Pressing this key one time measures the distance in normal mode.Pressing this key twice measures the distance in coarse mode.
[TARGET] Select the target type by following order. PRISM / REFRECTORLESS (V-227N models only)
[0 SET] Resets the horizontal angle to 0° 0’ 0” by pressing twice.
[DISP] Switches the display composition in the order “H.angle / H.dst. / V.dst.”, “H.angle / V.angle / S.dst.” and “H.angle / V.angle / H.dst. / S.dst. / V.dst.”
[MODE] Switches the screen between MODE A and MODE B.
11
MODE B
[S.FUNC] PowerTopoExpress Special Functions
[ANG SET] Brings up the angle setting screen for setting angle-related parameters. (H.ANGLE / %GRADE, H.ANGLE INPUT and R/L REVERSE)
[HOLD] Pressing this key twice retains (holds) the horizontal angle shown on the display.
[CORR] Brings up the screen for changing the target constant,temperature,Pressure setting.
[MODE] Switches the screen between MODE A and MODE B.
12
1.5 Angle Measurement
1.5.1 Horizontal Angle
Set the screen MODE A : MODE A screen
Control keys for measuring horizontal angle:
To set the angle to 0 :
To hold the angle :
To release HOLD :
To input an angle :
input value by using :
To read clockwise angle :
1.5.2 Vertical angle
To display vertical angle :
To read the slope % :
x2
13
1.6 Distance Measurement
Set the screen MODE A : MODE A screen
1.6.1 Select your target (V-227N models only)
Select target type (measurement mode):
(Prism) (Reflector-less)
1.6.2 Distance measurement
For a single shot measurement :
For tracking measurement :
1.6.3 Changing Target constants The default constants are:
Prism : -30mm Reflector-less : always 0mm (V-227N models only)
Before changing the constants,set Target Constant in the Initial Setting to “INPUT”mode:
To change Prism constant:
input value by using:
NOTE: The selected target is maintained until next time you change
NOTE: The number of shots can be defined. The default is “one time”.The measuring modes activated by the above operations can be also changed.
x2
14
1.6.4 Input Temperature and Atmospheric pressure
To Input temperature :
input value by using:
To Input atmospheric pressure:
input value by using:
1.6.5 Adjusting LCD contrast
1.6.6 Adjusting Illumination brightness
for LCD
for Reticle
x2
X3
+or
+or
+or
15
2. Changing Instrument settings
2.1 Help menu
While the screen is in MODE A or MODE B,
2.2 Instrument setting items
HELP menu list (Default) Other optionsPRISM CONST (-30mm), 0mm, INPUT
ATM CORR (ATM INPUT), ppm INPUT, NIL
SHOT CONT (1 time), 3 times, 5 times, INPUTSHOT COUNT
SHOT INPUT (01 times), input
CRV/ REF CORR (0.14), 0.2, NIL
ATM CORR DISP (OFF), ON
MIN UNIT ANG. (FINE), COARSE
V. ANG. STYLE (Z. 0), H. 0, COMPASS
QUAD BUZ (OFF), ON
AUTO OFF (10 MIN), 20 MIN, 30 MIN, NIL
EDM OFF (3 MIN), 5 MIN, 10 MIN, NIL
COMPENSATOR (ON), OFF
TEMP. UNIT (Centigrade), Fahrenheit ATM UNIT
PRESS UNIT (hPa), mmHg, inchHg
DIST. UNIT (m), ft, ft+ inch
ANG. UNIT (DEG), DEC, GRD, MIL
BAUD RATE (1200), 2400, 4800, 9600
DATA LENGTH (8), 7
PARITY BITS (NIL), EVEN, ODD
STOP BITS (1), 2
SIGNAL CONTROL (ON), OFF
XON/ XOFF (ON), OFF
SET UP COM.
THROUGH COMMAND (NIL), a, b, c, d, e, f
Select a desired item by or
Change the setting
NOTE: Some items have sub-menus where the selecting procedureby using direction keys is again repeated.
16
3. Warning and Error Messages
Warning Message Meaning What to do
Out of tilt range Displayed when the instrument is tiltedbeyond the vertical compensation range (±3’)in case automatic compensation is selected.This message may be temporarily displayedif the instrument is turned too fast.
Re-level the instrument.Repair is needed if themessage is displayedwhen it is properlyleveled.
Excess data The input data exceeds the allowable range. Press the [ESC] key andenter the correct data.
MismatchedTarget
This message is displayed if a long distancewhich is a far beyond measurable distanceof V-227N is measured with a wrongtarget mode. lease select a correct target then measure.If a wrong target is selected, a correctdistance cannot be measured.
Select the correct target,mode.
Target is tooclose.
The measurement distance is less than1.5m in Prism mode.
Select a longer point,or use a tape measure.
UnsuitableCondition
•Under too strong sun light.•Unstable light value owing to shimmer or obstacles.•Target,Prism do not face the instrument.•Target,Prism are not correctly sighted.• Measurement range is over in Reflectorless mode.• Sufficient signal does not return by sighting sharp edge etc. at Reflectorless mode.
Change the objectthat has much betterreflectivity, or use aprism, or wait untilthe sun activity hasweakened.
Error Message Meaning What to do
EDM ERROR04 -05, 34-39, 50-53
Distance measurement system problem
ETH ERROR70-76
Angle measurement system problem
MEMORY ERROR 19
Memory problem
ERROR PS DATA of EDMERROR P DATA of EDM
Problem of the internal EDM parameters
ERROR ETH DATA Problem of the internal ETH parameters
Turn the power off,and then turn on again.Repair is needed whenthe message appearsconsistently.
17
4. Specifications
V-227 N V-227Telescope
Magnification 30 xResolving power 3”Field of view 2.6% (1° 30’)Minimum focus 1.0mFocus Manual
Distance measurementLaser Class Visible Laser: Class II (2)Measurement range (Good condition)
Reflectorless 1.5m – 90m -Mini prism 1.5m-800m (1100m) 1.5m-600m (900m)1P 1.5m-1400m (1900m) 1.5m-1000m (1300m)3P 1.5m-1900m (2400m) 1.5m-1300m (1600m)
AccuracyPrism ±(3+2ppm x D)mmReflectorless ±(5+2ppm x D)mm -
Measuring timeRepeat meas. Normal:Prism 2.0sec.(1mm)
Track: Prism 0.4sec.(1cm)Angle measurement
Measuring method Absolute rotary encoderMinimum count 5” (10cc) /10” (20cc) selectableAccuracy(ISO17123-3) 7”Compensator Single axis
Sensitivity of vialsPlate level 40”/1div.Circular level 8’/2mm
Dimensions/WeightInstrument 172(W) x 343(H) x 177(L)mmWeight (incl. Battery) 5.4kg
Battery pack BP02Power source Ni-MH (Rechargeable)(4300mAh) ,DC6VOperation time Continuous Approx.5 hrs (ETH+EDM),12 hrs (ETH) with Approx.
2.2 hrs of charging timeInternal Memory
Coordinates data 6000 points Others
Data communication RS-232C Water resistant IP44 (instrument only)Ambient temperature -20°C ~ +50°C / -4°F ~122°F (Working range)Tripod thread 5/8” x 11Charger BC03 and AC Adapter AC01
Input voltage (AC01) :100~240V Output voltage (BC03) :DC7.5V
Base DetachablePlummet Optical
C
M
Y
CM
MY
CY
CMY
K
V200Quick01-07Aug2p17.pdf 30-08-2006 11:18:06V200Quick01-07Aug2p17.pdf 30-08-2006 11:18:06
18
NOTE:* The measurement range may vary by measurement conditions.
* Normal conditions: 20km visibility with slight shimmer.
* Good conditions: 40km visibility, overcast, no heat, no shimmer and moderate wind.
* EDM Measuring time varies according to distance to be measured and conditions of the environment.
* The operating time becomes shorter under the low temperature, due to the temperature dependence of the battery performance.
* The points that can be recorded in one job file are maximum 2,000 measuring points(XYZ).The user can make up to 8 job files.
19
To assure compliance with the Safety standard 21 CFR, Chapter 1. Subchapter J. The U.S. bureau of Radiological Health requires the following information to be provided to user.:
It can be dangerous to look into the beam with optical equipment such as binoculars and telescopes.
1. Specifications of Laser Radiation
A) The EDM module of the V-200 produces a visible light beam,which is emitted from the telescope objective lens and thecenter hole of the instrument base plate. The V-200 is designedand built to have a laser diode radiating at 620-690nm.
B) Radiant power The V-200 is designed and built to radiate a maximum average radiant power of 0.95mW from the telescope.The user may be subject to this radiation as a beam while operation until such
time that the instrument is turned off.
2.The following labels are affixed to and must remain attached to this laser product.
A) The following Certification label is located near the Plate level:“This laser product is complied with the provisions of 21 CFR1040. 10 and 1040.11. For a Class II laser product.”
B) Caution label is located near the exit aperture:“AVOID EXPOSURE.Laser radiation is emitted from this aperture.”
C) Warning logotype is located on the surface of the telescope: “CAUTION LASER RADIATION DO NOT STARE INTO BEAM”
D) Warning label is Located near the exit aperture.
NOTICE TO THE USER OF THIS PRODUCT
20
3.Caution to maintain the safety in compliance with the standard
A) To maintain the safety standard, refrain from any operation,maintenance, or adjustment other than described in thisinstruction manual.
B) Operation, maintenance or adjustment other than thosespecified in this instruction manual may result in hazardousradiation exposure.
C) Maintenance and repair not covered in this manual must be done by an authorized Pentax dealer.
D) The Laser beam emission by the Distance measurement can be terminated by pressing [Meas] or [ESC]key.
21
Aperture label
Warning label
Laser beam is transmitted from this aperture
LED is turned on at the time of emission
V-227N
V-227
Identification label
22
Warning logotype
Warning logotype
Warning logotype
23
Power Topo Express Operating Procedure
24
5. Starting Special Function
6. Creating / Selecting a Job File
To create a new job file:
Or to select a job file:
MODE A SCREEN
PowerTopoExpressMAIN MENU
PowerTopoExpress MAIN MENU
PowerTopoExpress MAIN MENU
NOTE: Once a job file is created or selected, it is effective until a new job file is created or another job file is selected.The default job file
"PENTAX" is provided permanently so that data is stored even when no user defined job file exists.The points that can be recorded in one job file are maximum 2,000 measuring points(XYZ).The user can make up to 8 job files.
x2 x2
select a job file by using
input a new job name by using
25
7. Input a Known Point Coordinate
To input and store a known point coordinate:
To input PC (point code):
PowerTopoExpress MAIN MENU
x2
input a Point Name by using
x2repeat to input value
X-Z,PC(point code)
NOTE: There are other functions in VIEW menu; Graphical View, EditRectangular Data, and Edit Polar Data. For detail of thesefunc t i ons , p lease re fe r t o t he i ns t ruc t i on manua l o fPowerTopoExpress.
select a PC from the list by using
NOTE: PC list is displayed only when point codes are stored in thejob named “PointColeList”. “PointCodeList”job can be createdby the procedure described in the section 2, and PC can bestored by inputting PN and PC as a point coordinate data. PClist can be also transferred from a computer. For more detail,r e f e r t o t h e i n s t r u c t i o n m a n u a l o f P o w e r T o p o L i t e .A new point code can be input and memorized as a pointcoo rd ina te da ta , bu t i t i s no t s to red as t he da ta o f“PointCodeList”. If a new PC need to be added to the list,se l ec t “Po in t Cod eL i s t ” j o b an d ad d a PC as a ne wRect.Coord.Data.
x2
input PC
move cursor to PC
26
8. Rectangular Coordinate Measurement
8.1 Station Point Setup
To select from the memory:
Or to input the station point information:
PowerTopoExpress MAIN MENU
STATION POINT SETUP
H.ANGLE SETUP
input a Point Name by using
NOTE:
The input item (cursor position) may be selected by
x2
repeat to input value
X-Z,PC(point code)
input PC
H.ANGLE SETUP
select the point by using
,
SAVE or
SAVE
27
To input PC (point code):
8.2 Orientation (Station Point H.Angle Setup)
To input a given angle:
Or to set the angle 0°:
Or to calculate by the Back Sight Point:
select a PC from the list by using
NOTE: Input items are PN (point name), X, Y, Z, IH (instrument height), and PC (point code). If the inputted PN already exists in the memory,then the corresponding point information (coordinate & point code) is displayed in the screen. The result of Free Station, prior to stakeout, is automaticallyset in the each field of Station Setup.
input value by using
MEASUREMENTSCREEN
MEASUREMENT SCREEN
input value or select from the list
aim Back Sight Point MEASUREMENT
SCREEN
move cursor to PC
28
8.3 Measurement
To select the Target type: (V-227N models only)
To measure:
Or to start tracking:
To input the point information:
To save the point information:
x2Repeat Until the desired target type is selected
NOTE: You can check the selected target type at the left side of theBattery mark in the top line of the screen.
x2
NOTE:
Shot count can be changed by using x2
select by or
input value by using
RETURN TO THE MASUREMENT
SCREEN
( next measurement )
input PC SAVE
29
Or to measure and save:
8.4 Offset Measurement
For Radial Offset (the horizontal distance offset along the line of measurement):
For Tangential Offset:
For Distance Offset (slope distance):
( next measurement )
NOTE: The Point number is automatically incremented or decrementedto make rapid continuous measurements possible.
MEASUREMENT SCREEN
input value by using
RETURN TO THE MASUREMENT
SCREEN
MEASUREMENT SCREEN
input value by using
RETURN TO THE MASUREMENT
SCREEN
X3
MEASUREMENT SCREEN
input value by using
RETURN TO THE MASUREMENT
SCREEN
X2
30
8.5 Remote measurement
To enter the Remote mode:
or
NOTE: The Offset values are cleared once the measurement is saved.
MEASUREMENT SCREEN
RETURN TO THE MEASUREMENT VALUES ARE UPDATED BY TURNING THE TELESCOPE
X2X2
( next measurement )
select by or
input value by using
input PC
MEASUREMENT SCREEN
REMOTE MODE MEASUREMENT VALUES ARE UPDATED BY TURNING
THE TELESCOPE
X2
( next measurement )
select by or
input value by using
input PC
31
To change the reference plane type:
To quit the Remote mode:
9. Polar Coordinate Measurement
9.1 Station Point SetupTo input the point information:
NOTE: Remote values are calculated based on the assumption of the reference plane. Three types of the reference plane are available in PowerTopoExpress; Cylindrical surface, Fixed plane (default) and Rotated plane.
PowerTopoExpress MAIN MENU
X4
Select by or
X2
MEASUREMENTSCREEN
POLAR CORRD.
PowerTopoExpress MAIN MENU
input a Point Name by using
repeat to input value
H.ANGLE SETUP
or confirm “ppm”
32
9.2 Orientation (Station Point H.Angle Setup)
Only when the orientation of the horizontal angle is required, proceed according to the following procedure.Otherwise, just pass this step by
To input a given angle:
Or to set the angle 0°:
Or to calculate by the Back Sight Point:
NOTE: Input items are PN (point name), IH (instrument height),PC (point code), TEMP (temperature), PRESS (atmospheric pressure) and ppm. "TEMP" and "PRESS" can be input only when "Atmospheric Correction" is set to "ATM INPUT"."ppm" can be input only when "Atmospheric Correction" is set to "ppm INPUT".The input item (cursor position) may be selected by
input value by using
MEASUREMENTSCREEN
MEASUREMENT SCREEN
select Start Point from the list
MEASUREMENTSCREEN
select End Point from the list
X2
33
9.3 Measurement
To select the Target type: (V-227N models only)
To measure:
Or to start tracking:
To input the point information:
To save the point information:
x2Repeat Until the desired target type is selected
NOTE: You can check the selected target type at the left side of theBattery mark in the top line of the screen.
x2
NOTE:
Shot count can be changed by using x2
input value by using
RETURN TO THE MASUREMENT
SCREEN
( next measurement )
input PC
input a Point Name by using
34
Or to measure and save:
9.4 Offset measurement
For Radial Offset (the horizontal distance offset along the line of measurement):
For Distance Offset (slope distance):
( next measurement )
NOTE: The point number is automatically incremented or decrimentedfor rapid continuous measurements.
MEASUREMENT SCREEN
input value by using
RETURN TO THE MASUREMENT
SCREEN
MEASUREMENT SCREEN
input value by using
RETURN TO THE MASUREMENT
SCREEN
NOTE: The Offset values are cleared once the measurement is saved.
35
10. Free Stationing
10.1 Known Point Setup
To select from the memory:
Or input PN which is already stored in memory to call and display the known coordinate
10.2 Measurement
Select the target type and measure:
To proceed to the next point:
Repeat "Known Point Setup" and "Measurement" for all known points.
PowerTopoExpress MAIN MENU
MEASUREMENT SCREEN
select the point by using
X3
input Inst.Height (IH) by using
KNOWN POINTSETUP
,
Repeat Until the desired target type is selected (V-227N models only)
NOTE: You can check the selected target type at the left side of theBattery mark in the top line of the screen.
KNOWN POINTSETUP
36
10.3 Calculation
11. Stake Out
11.1 Station Point Setup
Select from the stored data:
Or input PN which is already stored in the memory to call and display the known coordinate
MEASUREMENT SCREEN
input a Point Name by using
select Point Code from the list or input
PowerTopoExpressMAIN MENU
NOTE: The result of Free Station is automatically carried forward tothe station setup of Rectangular coordinate measurementand stakeout.
PowerTopoExpress MAIN MENU
X4 X2
STATION POINT SETUP
H.ANGLE SETUP
select the point by using
,
NOTE: The result of Free Station, prior to stakeout, is automatically set in the each field of Station Setup.
37
11.2 Orientation (Station Point H.Angle Setup)
To input a given angle:
Or to set the angle 0°:
Or to calculate by the Back Sight Point:
11.3 Stakeout Point Setup
Select the point from the stored data:
11.4 Stakeout Measurement
Check the designed value, and press to proceed to the Stakeout screen. Turn the instrument until "DH. Angle" reads to "0". Select the Target type:
input value by using
STAKEOUT COORD.SETUP
STAKEOUT COORD.SETUP
input value or select from the list
aim Back Sight Point STAKEOUT
COORD.SETUP
select the point by using
,
STAKEOUT MEASUREMENT
38
To measure in Tracking mode:
To confirm the position of the stake:
To proceed to the next point:
x2
Repeat Until the desired target type is selected (V-227N models only)
NOTE: You can check the selected target type at the left side of theBattery mark in the top line of the screen.
(move the target until “DH.dist” reads “0”)
To quit measurement (position the target accurately)
Input PN, PH and PC
RETURN TO STAKEOUT MASUREMENT
SCREEN
STAKEOUT MEASUREMENT
(repeat from “Stakeout Point Setup“)
39
12. Stake Out (Point to Line)
"Point to Line" gives the distances between SOP and Int.P,A and Int.P,B and Int.P.
12.1 Station Point Setup
Select the point from the stored data:
12.2 Orientation (Station Point H.Angle Setup)
To input a given angle:
Or to set the angle 0°:
PowerTopoExpress MAIN MENU
X4
STATION POINTSETUP
H.ANGLE SETUP
select the point by using
,
NOTE: The result of Free Station, prior to stakeout, is automatically set in the each field of Station Setup.
input value by using
POINT A SETUP
POINT A SETUP
40
Or to calculate by the Back Sight Point:
12.3 Point A Setup
To input values:
Or to select from the memory:
12.4 Point B Setup
To input values:
input value or select from the list
aim Back Sight Point POINT A SETUP
input a Point Name by using
repeat to input value
X-Z,PC(point code)
input PC
POINT B SETUP
select the point by using
,
POINT B SETUP
SAVE or
input a Point Name by using
SAVE
41
Or to select from the memory:
12.5 Point To Line Measurement
To select the Target type:
To measure in Tracking mode:
To confirm the position of the stake:
repeat to input value
X-Z,PC(point code)
input PC
select the point by using
,
SAVE orMEASUREMENT
MEASUREMENT
x2
Repeat Until the desired target type is selected (V-227N models only)
(move the target to the desired position)
To quit measurement (position the target accurately)
Input PN, PH and PC
RETURN TO STAKEOUT MASUREMENT
SCREEN x2
SAVE
42
13. INVERS
To input SP (Station point):
14. Area Calculation
To start area calculation:
To return to the calculation menu screen:
PowerTopoExpress MAIN MENU
X3
input a Point Name by using
repeat to input value
X-Z,PC(point code)
input PC
SAVE or
Input End point
RESULT SCREEN
PowerTopoExpress MAIN MENU
X3
select points of the polygon by repeating select
RESULT SCREEN
RESULT SCREEN
RESULT SCREEN
x2
CALCULATION MENU SCREEN
43
15. REM
To start REM:
Measure the Reference point:
Measure the elevation of the remote point:
To return to Calculation menu:
NOTE: Th is func t ion ca lcu la tes the leng th o f 2D con tour o fa polygon, and the 2D sur face (area) of the polygon.The polygon is defined by selecting points in such a way thatthe contour segments of the polygon do not intersect .The last selected point is automatically t ied to the f irsts e l e c t e d p o i n t t o f o r m t h e c l o s e d f i g u r e .There are several function keys for point selection, such as"ALL", "FIND PN", FROM", "TO", and "ORDER". Refer to theinstruction manual on the CD-R.
PowerTopoExpress MAIN MENU
X3 x2
input prism (or reference) height
aim the point to be measured
REM VALUE IS DISPLAYED AT THE
BOTTOM OF THE SCREEN
CALCULATION MENU SCREEN
x2
44
16. RDM (Remote Distance Measurement)
To start RDM:
Measure the Reference point:
Measure the 2nd point (Target Point):
Measure the 3rd point (Target Point):
To return to PowerTopoLite Main menu:
PowerTopoExpress MAIN MENU
X2
MEASURE THE REFERENCE
POINT
input the target height by
(select target if necessary)
RESULT SCREEN DISTANCE FROM THE REFERENCE POINT
RESULT SCREENDISTANCE FROMTHE PREVIOUSTARGET POINT
RESULT SCREENDISTANCE FROMTHE REFERENCE
POINT
RESULT SCREEN DISTANCE FROM THE PREVIOUS TARGET POINT
X2
(repeat reference point measurement)
RESULT SCREEN PowerTopoExpressMAIN MENU
45
Pre
fere
nce L
ist
Rem
ark
Axis
la
be
ls th
at
are
dis
pla
yed
in
1st
line,
2n
d
line
, an
d 3
rd lin
e
Orie
nta
tio
n d
ire
ctio
n o
f
ea
ch
axis
.
Dire
ctio
n o
f H
.ang
le
me
asu
rem
en
t
Op
era
tio
na
l p
roced
ure
t yp
e
Sta
ke O
ut scre
en
"AIM
" m
essa
ge
ON
/OF
F
Op
tio
ns
Yo
ur
La
ng
uag
e
An
y a
lph
a-n
um
eric c
hara
cte
r
An
y a
lph
a-n
um
eric c
hara
cte
r
An
y a
lph
a-n
um
eric c
hara
cte
r
RIG
HT
AN
GL
E, H
EIG
HT
BA
SE
DIR
EC
TIO
N,
HE
IGH
T
BA
SE
DIR
EC
TIO
N,
RIG
HT
AN
GLE
CC
W
DIV
IDE
D T
EM
PL
AT
E, M
AT
RIX
ST
RU
CT
UR
E T
YP
E
CY
LIN
DE
R F
AC
E,
RO
TA
TE
D P
LA
TE
LA
RG
E C
HA
RA
CT
ER
ON
-99
99.9
99
m -
+9
999
.99
9m
0.0
00
00
001
- 1
.999
999
99
ON
Defa
ult
EN
GL
ISH
X Y Z BA
SE
RIG
HT
AN
GL
E
HE
IGH
T
CW
FU
LL
TE
MP
LA
TE
PR
OC
ES
S T
YP
E
FIX
ED
PLA
NE
ALL I
N O
NE
IN
FO
.
OF
F
0m
1.0
OF
F
DIS
P.1
DIS
P.2
DIS
P.3
DIS
P.1
AX
IS
DIS
P.2
AX
IS
DIS
P.3
AX
IS
RO
TA
TIO
N
AV
E.E
LE
V
SC
AL
E
Item
La
ng
uag
e
CO
OR
D.A
XIS
INP
UT
ME
TH
OD
AC
TIO
N M
ET
HO
D
RE
MO
TE
ME
TH
OD
CO
MP
AR
E M
ET
HO
D
RE
QU
ES
T A
IMIN
G
EL
EV
. F
AC
TO
R
DU
PL
ICA
TE
PN
CH
K
Function ListV-227N V-227
FILE MANAGEMENT INFORMATION Yes YesCREATE Yes YesDELETE Yes YesALL CLEAR Yes Yes
MEASURE RECTANGULAR COORD. Yes YesPOLAR COORD. Yes -
VIEW&EDIT GRAPHICAL VIEW Yes YesCREATE THE RECT.POINT Yes YesEDIT THE RECT.DATA Yes YesEDIT THE POLAR DATA Yes -
FREE STATION Yes YesSTAKEOUT STAKE OUT Yes Yes
POINT TO LINE Yes YesCALCULATION INVERSE Yes Yes
2D SURFACE Yes YesREM Yes Yes
RDM Yes YesTRANSFER RECEIVE DC1 Yes Yes
RECT.DATA CSV Yes YesExtCSV Yes Yes
SEND RECT.DATA DC1 Yes YesCSV Yes YesExtCSV Yes Yes
SEND POLAR DATA DC1 Yes -AUX Yes -
COMMUNICATION RECEIVE SETUP RECT.DATA Yes Yes
SENDRECT. DATA Yes YesSENDPOLAR DATA Yes -
PREFEREMCE LANGUAGE Yes YesCOORD.SYSTEM Yes YesINPUT METHOD Yes YesACTION METHOD Yes YesREMOTE METHOD Yes YesCOMPARE METHOD Yes YesREQUEST AIMING Yes YesELEV.FACTOR Yes YesDUPLICATE PN CHK Yes Yes
46
PAG46 QG V-200 15-09-2006 15:37 Pagina 1
Japan Surveying Instruments Manufacturers’ Association
Member symbol of the Japan SurveyingInstruments Manufacturers’Association representing the high quality surveying products.
Prin
ted
in B
elgi
um
Total Construction Solutions
082006 V200-Q01A
PENTAX Industrial Instruments Co., Ltd.2-5-2 Higashi-Oizumi
Nerima-Ku, Tokyo 178-8555, JapanTel. +81 3 5905 1222Fax +81 3 5905 1225
E-mail: [email protected]: www.pentax.co.jp/piic/survey
www.pentaxsurveying.com