Teck 90 Armoured Power
Universal Toll Free Phone: 1.877.777.5776 | 15
CONDUCTOR
SHIELD
OUTER JACKET
ARMOUR
CONDUCTOR
CONCENTRIC COPPER
BOND CONDUCTOR
INSULATIONINNER JACKET
TAPE
19002-02-060 6 8 0.090 0.390 0.680 0.900 0.990 144 214 510 770 112 3/3A 3/3A
19002-03-060 4 6 0.090 0.430 0.720 0.940 1.030 224 333 590 880 148 3/3A 3/3A
19002-04-060 2 6 0.090 0.490 0.780 1.030 1.120 302 449 750 1120 195 3/3A 3/3A
19002-05-060 1 4 0.090 0.520 0.810 1.000 1.150 406 604 870 1300 225 4/4A 4/4A
19002-06-060 1/0 4 0.090 0.560 0.880 1.130 1.220 475 707 1010 1500 260 4/4A 4/4A
19002-07-060 2/0 4 0.090 0.600 0.920 1.170 1.260 562 836 1120 1670 299 4/4A 4/4A
19002-08-060 3/0 3 0.090 0.640 0.970 1.220 1.310 709 1055 1300 1930 345 4/4A 4/4A
19002-09-060 4/0 3 0.090 0.700 1.020 1.270 1.360 843 1255 1470 2180 400 5/5A 5/5A
19002-10-060 250 2 0.090 0.750 1.100 1.380 1.480 1013 1508 1680 2500 444 5/5A 5/5A
19002-12-060 350 1 0.090 0.850 1.240 1.520 1.620 1389 2067 2120 3150 549 6/6A 6/6A
19002-14-060 500 1/0 0.090 0.970 1.340 1.620 1.720 1928 2869 2770 4130 688 6/6A 6/6A
19002-16-060 750 2/0 0.090 1.150 1.540 1.830 1.930 2820 4197 3780 5760 889 7/7A 7/7A
19002-17-060 1000 2/0 0.090 1.300 1.760 2.050 2.150 3607 5368 5010 7460 1061 8A 8A/8B
Part
Number
AWG SizeInsulation
Thickness
(in.)
Approximate
Diameter (Over)
Copper
ContentNet Weightw/ Armour Amp.
(40°CAmbient)
Recommended
Connector*
Cond.BondWire
Insul.(in.)
InnerJacket
(in.)
Armour(in.)
OuterJacket
(in.)
LB/MFT
KG/KM
LB/MFT
KG/KM TMC2 TMC2X
SPE CIFI C AT IO NS CONST RUC TI ON
Shielded One Conductor90 MIL 100%/133% 5kV
TR-XLPE/PVC/AIA/PVC
• CSA FT1 & FT4
• CSA C22.2 No. 131 & 174
• CSA C68.3
• IEEE 383 & 1202 (70,000BTU/hr) Flame Test
• ICEA T-29-520 (210,000
BTU/hr) Vertical Flame Test
• ICEA T-30-520 (70,000BTU/hr) Vertical Flame Test
*Refer to CE Code for details
HL
Note: All dimensions are nominal and are subject to normal manufacturing tolerance.
Specifications are subject to change without prior notice.
* See pages 30 & 31 for corresponding connector.
Non-ferrous connectors only.
Conductor: Bare copper Class B compact or compressed stranded
Conductor Shield: Extruded thermoset semi-conducting shield
Insulation: Tree-Retardant Cross-Linked Polyethylene (TR-XLPE)
Insulation Shield: Extruded thermosetting semi-conducting shield
Ground (Bonding/Shield) Conductor: Stranded bare copper conductor
Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
Armour: Aluminum Interlocked Armour (AIA)
Outer Jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), orange
Options: Other coloured outer jacket and constructions available upon request
-
8/9/2019 Texcan Teck Medium Voltage Shielded.pdf
2/13
Teck 90 Armoured Power
16 | Universal Toll Free Phone: 1.877.777.5776
C ON T R OL S H I E L D E D
19008-02-060 6 8 0.090 0.900 1.170 1.450 1.540 349 519 1120 1670 93 5/5A 5/5A
19008-03-060 4 8 0.090 0.430 1.260 1.540 1.630 503 749 1350 2010 122 6/6A 6/6A
19008-04-060 2 6 0.090 0.490 1.390 1.670 1.770 771 1147 1740 2590 159 6A/7 6A/7
19008-05-060 1 6 0.090 0.520 1.450 1.730 1.830 939 1397 1960 2920 184 7/7A 7/7A
19008-06-060 1/0 6 0.090 0.560 1.530 1.810 1.910 1148 1708 2290 3410 211 7/7A 7/7A
19008-07-060 2/0 6 0.090 0.600 1.620 1.910 2.010 141 2104 2620 3900 243 8A 8A/8B
19008-08-060 3/0 4 0.090 0.640 1.780 2.070 2.170 1798 2668 3210 4780 279 8A 8A/8B
19008-09-060 4/0 4 0.090 0.700 1.900 2.190 2.290 2212 3292 3720 5530 321 8A 8A/8B
19008-10-060 250 4 0.090 0.750 2.010 2.300 2.430 2583 3844 4300 6400 355 9/9A 9/9A/9B
19008-11-060 300 4 0.090 0.890 2.115 2.355 2.495 3058 4551 4980 7411 372 9/9A 9/9A/9B
19008-12-060 350 3 0.090 0.906 2.210 2.450 2.590 3569 5311 5638 8390 435 9/9A 9/9A/9B
19008-13-060 400 3 0.090 0.960 2.315 2.555 2.695 4054 6033 6202 9230 429 10/10A 10/10A
19008-14-060 500 2 0.090 0.970 2.480 2.770 2.900 4998 7438 7130 10610 536 10/10A 10/10A
19008-16-060 600 2 0.090 1.115 2.645 2.885 3.025 5991 8916 8471 12606 534 10/10A 10/10A
19008-20-060 750 2 0.090 1.150 2.980 3.270 3.420 7440 11072 10330 15370 668 11/11A 11/11A
19008-25-060 1000 1 0.090 1.300 3.310 3.600 3.750 9860 14674 13080 19460 768 12/12A 12/12A
Part
Number
AWG SizeInsulation
Thickness
(in.)
Approximate
Diameter (Over)
Copper
ContentNet Weightw/ Armour Amp.
(40°CAmbient)
Recommended
Connector*
Cond.BondWire
Insul.(in.)
InnerJacket
(in.)
Armour(in.)
OuterJacket
(in.)
LB/MFT
KG/KM
LB/MFT
KG/KM TMC2 TMC2X
SPE CIFI C AT IO NS CONST RUC TI ON
Shielded Three Conductor90 MIL 100%/133% 5kV
TR-XLPE/PVC/AIA/PVC
• CSA FT1 & FT4
• CSA C22.2 No. 131 & 174
• CSA C68.3
• IEEE 383 & 1202 (70,000BTU/hr) Flame Test
• ICEA T-29-520 (210,000
BTU/hr) Vertical Flame Test
• ICEA T-30-520 (70,000BTU/hr) Vertical Flame Test
*Refer to CE Code for details
Note: All dimensions are nominal and are subject to normal manufacturing tolerance.
Specifications are subject to change without prior notice.
* See pages 30 & 31 for corresponding connector.
Conductor: Bare copper Class B compact or compressed stranded
Conductor Shield: Extruded thermoset semi-conducting shield
Insulation: Tree-Retardant Cross-Linked Polyethylene (TR-XLPE)
Insulation Shield: Extruded thermosetting semi-conducting shield
Metallic Shield: Helically applied 15% gapped copper tape
Ground (Bonding) Conductor: Stranded bare copper conductor
Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
Armour: Aluminum Interlocked Armour (AIA)
Outer Jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), orange
Options: Galvanized Steel Interlocked Armour (GSIA)
Other coloured outer jacket and constructions available upon requestHelically applied 20% overlapped copper tape shield
INSULATION
BOND
CONDUCTOR
CONDUCTOR
SHIELD
OUTER JACKET
ARMOUR
FILLERS
INNER JACKET
CONDUCTOR
COPPER
TAPE
INSULATION
SHIELD
TAPE
HL
-
8/9/2019 Texcan Teck Medium Voltage Shielded.pdf
3/13
Part
Number
AWG SizeInsulation
Thickness
(in.)
Approximate
Diameter (Over)
Copper
ContentNet Weightw/ Armour Amp.
(40°CAmbient)
Recommended
Connector*
Cond.BondWire
Insul.(in.)
InnerJacket
(in.)
Armour(in.)
OuterJacket
(in.)
LB/MFT
KG/KM
LB/MFT
KG/KM TMC2 TMC2X
CONDUCTOR
SHIELD
OUTER JACKET
ARMOUR
CONDUCTOR
CONCENTRIC COPPER
BOND CONDUCTOR
INSULATIONINNER JACKET
TAPE
Teck 90 Armoured Power
Universal Toll Free Phone: 1.877.777.5776 | 17
19012-02-060 6 8 0.115 0.440 0.730 0.950 1.040 145 216 550 820 112 3/3A 3/3A
19012-03-060 4 6 0.115 0.480 0.770 0.990 1.080 225 335 680 1010 148 3/3A 3/3A
19012-04-060 2 6 0.115 0.540 0.830 1.080 1.170 303 451 840 1250 195 4/4A 4/4A
19012-05-060 1 4 0.115 0.570 0.910 1.160 1.250 407 606 960 1430 225 4/4A 4/4A
19012-06-060 1/0 4 0.115 0.610 0.940 1.190 1.280 453 674 1060 1570 260 4/4A 4/4A
19012-07-060 2/0 4 0.115 0.650 0.980 1.230 1.320 476 708 1170 1740 299 4/4A 4/4A
19012-08-060 3/0 3 0.115 0.700 1.030 1.310 1.400 563 838 1350 2000 345 5/5A 5/5A
19012-09-060 4/0 3 0.115 0.750 1.080 1.360 1.450 710 1057 1520 2260 400 5/5A 5/5A
19012-10-060 250 2 0.115 0.800 1.160 1.440 1.530 849 1263 1730 2580 444 5/5A 5/5A
19012-12-060 350 1 0.115 0.940 1.290 1.570 1.670 1169 1740 2170 3230 549 6/6A 6/6A
19012-14-060 500 1/0 0.115 1.020 1.410 1.690 1.790 1390 2069 2860 4260 688 6A/7 6A/7
19012-16-060 750 2/0 0.115 1.200 1.600 1.890 1.990 2821 4198 3940 5860 889 8/8A 8/8A/8B
19012-17-060 1000 2/0 0.115 1.350 1.810 2.100 2.200 3608 5369 5090 7570 1061 8A 8A/8B
SP EC IFI CAT ION S CONST RUC T I ON
Shielded One Conductor115 MIL 133% 5kV (aka 100% 8kV)
• CSA FT1 & FT4
• CSA C22.2 No. 131 & 174
• CSA C68.3
• IEEE 383 & 1202 (70,000BTU/hr) Flame Test
• ICEA T-29-520 (210,000
BTU/hr) Vertical Flame Test
• ICEA T-30-520 (70,000BTU/hr) Vertical Flame Test
*Refer to CE Code for details
HL
Note: All dimensions are nominal and are subject to normal manufacturing tolerance.
Specifications are subject to change without prior notice.
* See pages 30 & 31 for corresponding connector.
Non-ferrous connectors only.
Conductor: Bare copper Class B compact or compressed stranded
Conductor Shield: Extruded thermoset semi-conducting shield
Insulation: Tree-Retardant Cross-Linked Polyethylene (TR-XLPE)
Insulation Shield: Extruded thermosetting semi-conducting shield
Ground (Bonding/Shield) Conductor: Stranded bare copper conductor
Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
Armour: Aluminum Interlocked Armour (AIA)
Outer Jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), orange
Options: Other coloured outer jacket and constructions available upon request
(Per AEIC)
TR-XLPE/PVC/AIA/ PVC
-
8/9/2019 Texcan Teck Medium Voltage Shielded.pdf
4/13
-
8/9/2019 Texcan Teck Medium Voltage Shielded.pdf
5/13
Part
Number
AWG SizeInsulation
Thickness
(in.)
Approximate
Diameter (Over)
Copper
ContentNet Weightw/ Armour Amp.
(40°CAmbient)
Recommended
Connector*
Cond.BondWire
Insul.(in.)
InnerJacket
(in.)
Armour(in.)
OuterJacket
(in.)
LB/MFT
KG/KM
LB/MFT
KG/KM TMC2 TMC2X
INSULATION
BOND
CONDUCTOR
CONDUCTOR
SHIELD
OUTER JACKET
ARMOUR
FILLERS
INNER JACKET
CONDUCTOR
COPPER
TAPE
INSULATION
SHIELD
TAPE
19014-01-012 6 8 0.140 0.495 1.405 1.645 1.755 403 600 1434 2134 93 6A/7 6A/7
19014-04-012 4 8 0.140 0.535 1.490 1.730 1.840 513 763 1619 2409 122 6A/7 6A/7
19014-02-012 2 6 0.140 0.590 1.610 1.850 1.960 783 1165 2127 3165 159 7/7A 7/7A
19014-05-012 1 6 0.140 0.621 1.735 1.975 2.085 951 1415 2482 3694 184 8A 8A/8B
19014-06-012 1/0 6 0.140 0.658 1.815 2.055 2.165 1160 1726 2769 4121 211 8A 8A/8B
19014-07-012 2/0 6 0.140 0.702 1.910 2.150 2.260 1426 2122 3137 4668 243 8A 8A/8B
19014-08-012 3/0 4 0.140 0.749 2.010 2.250 2.390 1759 2618 3679 5475 279 9/9A 9/9A/9B
19014-09-012 4/0 4 0.140 0.801 2.125 2.365 2.505 2226 3313 4258 6337 321 9/9A 9/9A/9B
19014-10-012 250 4 0.140 0.643 2.215 2.455 2.595 2595 3862 4716 7018 355 9A 9A/9B
19014-13-012 300 4 0.140 0.896 2.325 2.570 2.710 3069 4567 5330 7932 372 10/10A 10/10A
19014-11-012 350 3 0.140 0.940 2.425 2.665 2.810 3583 5332 5977 8895 435 10/10A 10/10A
19014-14-012 400 3 0.140 0.985 2.520 2.760 2.900 4065 6049 6551 9749 429 10/10A 10/10A
19014-12-012 500 2 0.140 1.065 2.685 2.925 3.065 4935 7344 7590 11295 536 10/10A 10/10A
19014-15-012 600 2 0.140 1.140 2.920 3.160 3.330 6001 8390 9143 13606 534 11/11A 11/11A
19014-16-012 750 2 0.140 1.235 3.125 3.365 3.535 7438 11069 10891 16208 668 11/11A 11/11A
19014-17-012 1000 1 0.140 1.385 3.455 3.695 3.865 9868 14685 13765 20485 768 12/12A 12/12A
Teck 90 Armoured Power
Universal Toll Free Phone: 1.877.777.5776 | 19
S PE CIFI C AT IO NS CONST RUC TI ON
Shielded Three Conductor140 MIL 133% 8kV
TR-XLPE/PVC/AIA/PVC
• CSA FT1 & FT4
• CSA C22.2 No. 131 & 174
• CSA C68.3
• IEEE 383 & 1202 (70,000BTU/hr) Flame Test
• ICEA T-29-520 (210,000
BTU/hr) Vertical Flame Test
• ICEA T-30-520 (70,000BTU/hr) Vertical Flame Test
*Refer to CE Code for details
HL
Note: All dimensions are nominal and are subject to normal manufacturing tolerance.
Specifications are subject to change without prior notice.
* See pages 30 & 31 for corresponding connector.
Conductor: Bare copper Class B compact or compressed stranded
Conductor Shield: Extruded thermoset semi-conducting shield
Insulation: Tree-Retardant Cross-Linked Polyethylene (TR-XLPE)
Insulation Shield: Extruded thermosetting semi-conducting shield
Metallic Shield: Helically applied 15% gapped copper tape
Ground (Bonding) Conductor: Stranded bare copper conductor
Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
Armour: Aluminum Interlocked Armour (AIA)
Outer Jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
Options: Galvanized Steel Interlocked Armour (GSIA)
Other coloured outer jacket and constructions available upon requestHelically applied 20% overlapped copper tape shield
-
8/9/2019 Texcan Teck Medium Voltage Shielded.pdf
6/13
Part
Number
AWG SizeInsulation
Thickness
(in.)
Approximate
Diameter (Over)
Copper
ContentNet Weightw/ Armour Amp.
(40°CAmbient)
Recommended
Connector*
Cond.BondWire
Insul.(in.)
InnerJacket
(in.)
Armour(in.)
OuterJacket
(in.)
LB/MFT
KG/KM
LB/MFT
KG/KM TMC2 TMC2X
19020-04-032 2 6 0.220 0.760 1.090 1.340 1.430 286 426 1028 1530 195 5/5A 5/5A
19020-05-032 1 4 0.220 0.790 1.120 1.370 1.460 391 582 1170 1740 225 5/5A 5/5A
19020-06-032 1/0 4 0.220 0.830 1.160 1.410 1.500 459 683 1270 1890 259 5/5A 5/5A
19020-07-032 2/0 4 0.220 0.860 1.200 1.450 1.540 546 813 1390 2060 298 5/5A 5/5A
19020-08-032 3/0 3 0.220 0.910 1.250 1.500 1.590 693 1031 1570 2340 343 5/5A 5/5A
19020-09-032 4/0 3 0.220 0.960 1.300 1.580 1.680 830 1235 1780 2650 397 6/6A 6/6A
19020-10-032 250 2 0.220 1.020 1.380 1.660 1.760 989 1472 2010 2990 440 6A/7 6A/7
19020-11-032 350 1 0.220 1.120 1.500 1.780 1.880 1228 1827 2490 3700 543 7/7A 7/7A
19020-12-032 500 1/0 0.220 1.240 1.650 1.940 2.040 1896 2821 3220 4790 678 8/8A 8/8A/8B
19022-12-032 750 2/0 0.220 1.420 1.890 2.180 2.280 2766 4116 4390 6530 872 8A 8A/8B
19022-25-032 1000 2/0 0.220 1.570 2.050 2.340 2.480 3552 5286 5550 8260 1040 9/9A 9/9A/9B
Teck 90 Armoured Power
20 | Universal Toll Free Phone: 1.877.777.5776
C ON T R OL S H I E L D E D
SPE CI FIC ATI ONS CON ST RU C T ION
Shielded One Conductor220 MIL 133% 15kV
TR-XLPE/PVC/AIA/ PVC
• CSA FT1 & FT4
• CSA C22.2 No. 131 & 174
• CSA C68.3
• IEEE 383 & 1202 (70,000BTU/hr) Flame Test
• ICEA T-29-520 (210,000
BTU/hr) Vertical Flame Test
• ICEA T-30-520 (70,000BTU/hr) Vertical Flame Test
*Refer to CE Code for details
CONDUCTOR
SHIELD
OUTER JACKET
ARMOUR
CONDUCTORINSULATION
CONCENTRIC COPPER
BOND CONDUCTOR
INSULATION
SHIELD
INNER JACKET
TAPE
HL
Note: All dimensions are nominal and are subject to normal manufacturing tolerance.
Specifications are subject to change without prior notice.
* See pages 30 & 31 for corresponding connector.
Non-ferrous connectors only.
Conductor: Bare copper Class B compact or compressed stranded
Conductor Shield: Extruded thermoset semi-conducting shield
Insulation: Tree-Retardant Cross-Linked Polyethylene (TR-XLPE)
Insulation Shield: Extruded thermosetting semi-conducting shield
Ground (Bonding/Shield) Conductor: Stranded bare copper conductor
Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
Armour: Aluminum Interlocked Armour (AIA)
Outer Jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), red
Options: Other coloured outer jacket and constructions available upon request
-
8/9/2019 Texcan Teck Medium Voltage Shielded.pdf
7/13
19022-01-032 2 6 0.220 0.760 2.020 2.310 2.430 793 1180 2665 3966 164 9/9A 9/9A/9B
19022-02-032 1 6 0.220 0.790 2.100 2.370 2.490 964 1435 3089 4597 187 9/9A 9/9A/9B
19022-03-032 1/0 6 0.220 0.830 2.170 2.460 2.580 1175 1749 3300 4900 215 9/9A 9/9A/9B
19022-04-032 2/0 6 0.220 0.860 2.260 2.550 2.670 1438 2140 3650 5430 246 9/9A 9/9A/9B
19022-05-032 3/0 4 0.220 0.910 2.360 2.650 2.770 1821 2710 4140 6160 283 10/10A 10/10A
19022-06-032 4/0 4 0.220 0.960 2.470 2.760 2.880 2248 3345 4680 6960 325 10/10A 10/10A
19022-07-032 250 4 0.220 1.020 2.590 2.880 3.000 2607 3880 5275 7850 359 10/10A 10/10A
19022-08-032 350 3 0.220 1.120 2.900 3.190 3.330 3597 5353 6842 10181 438 11/11A 11/11A
19022-11-032 500 3 0.220 1.240 3.160 3.450 3.590 5022 7474 8513 12668 536 11/11A 11/11A
19022-16-032 750 2 0.220 1.420 3.570 3.850 4.000 7452 11090 11507 17122 669 12/12A 12/12A
Part
Number
AWG SizeInsulation
Thickness
(in.)
Approximate
Diameter (Over)
Copper
ContentNet Weightw/ Armour Amp.
(40°CAmbient)
Recommended
Connector*
Cond.BondWire
Insul.(in.)
InnerJacket
(in.)
Armour(in.)
OuterJacket
(in.)
LB/MFT
KG/KM
LB/MFT
KG/KM TMC2 TMC2X
Teck 90 Armoured Power
Universal Toll Free Phone: 1.877.777.5776 | 21
SPE CI FIC AT IONS CO NST RU C T IO N
Shielded Three Conductor220 MIL 133% 15kV
TR-XLPE/PVC/AIA/PVC
• CSA FT1 & FT4
• CSA C22.2 No. 131 & 174
• CSA C68.3
• IEEE 383 & 1202 (70,000BTU/hr) Flame Test
• ICEA T-29-520 (210,000
BTU/hr) Vertical Flame Test
• ICEA T-30-520 (70,000BTU/hr) Vertical Flame Test
*Refer to CE Code for details
HL
Note: All dimensions are nominal and are subject to normal manufacturing tolerance.
Specifications are subject to change without prior notice.
* See pages 30 & 31 for corresponding connector.
Conductor: Bare copper Class B compact or compressed stranded
Conductor Shield: Extruded thermoset semi-conducting shield
Insulation: Tree-Retardant Cross-Linked Polyethylene (TR-XLPE)
Insulation Shield: Extruded thermosetting semi-conducting shield
Metallic Shield: Helically applied 15% gapped copper tape
Ground (Bonding) Conductor: Stranded bare copper conductor
Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
Armour: Aluminum Interlocked Armour (AIA)
Outer Jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), red
Options: Galvanized Steel Interlocked Armour (GSIA)
Other coloured outer jacket and constructions available upon requestHelically applied 20% overlapped copper tape shield
INSULATION
BOND
CONDUCTOR
CONDUCTOR
SHIELD
OUTER JACKET
ARMOUR
FILLERS
INNER JACKET
CONDUCTOR
COPPER
TAPE
INSULATION
SHIELD
TAPE
-
8/9/2019 Texcan Teck Medium Voltage Shielded.pdf
8/13
19023-02-012 1 4 0.320 0.990 1.365 1.605 1.715 385 573 1386 2063 164 6/6A 6/6A
19023-03-012 1/0 4 0.320 1.026 1.415 1.655 1.765 453 674 1568 2333 187 6A/7 6A/7
19023-04-012 2/0 4 0.320 1.066 1.455 1.695 1.805 538 801 1634 2432 215 7/7A 7/7A
19023-05-012 3/0 3 0.320 1.113 1.490 1.730 1.840 685 1019 1970 2932 246 7/7A 7/7A
19023-06-012 4/0 3 0.320 1.185 1.560 1.800 1.910 818 1217 2136 3179 283 7/7A 7/7A
19023-08-012 250 2 0.320 1.218 1.640 1.880 1.990 974 1449 2366 3521 325 8/8A 8/8A/8B
19023-10-012 350 1 0.320 1.315 1.800 2.040 2.150 1343 1999 2966 4414 359 8A 8A/8B
19023-12-012 500 1/0 0.320 1.454 1.940 2.180 2.290 1866 2777 3654 5438 438 8A 8A/8B
19023-14-012 750 2/0 0.320 1.620 2.105 2.350 2.485 2642 3932 4677 6960 536 9/9A 9/9A/9B
19023-15-012 1000 3/0 0.320 1.770 2.235 2.475 2.615 3491 5195 5665 8430 669 9/9A 9/9A/9B
Part
Number
AWG SizeInsulation
Thickness
(in.)
Approximate
Diameter (Over)
Copper
ContentNet Weightw/ Armour Amp.
(40°CAmbient)
Recommended
Connector*
Cond.BondWire
Insul.(in.)
InnerJacket
(in.)
Armour(in.)
OuterJacket
(in.)
LB/MFT
KG/KM
LB/MFT
KG/KM TMC2 TMC2X
Teck 90 Armoured Power
22 | Universal Toll Free Phone: 1.877.777.5776
C ON T R OL S H I E L D E D
SPE CI FIC AT IONS CO NST RU C T IO N
Shielded Single Conductor320 MIL 133% 25kV
TR-XLPE/PVC/AIA/PVC
• CSA FT1 & FT4
• CSA C22.2 No. 131 & 174
• CSA C68.3
• IEEE 383 & 1202 (70,000BTU/hr) Flame Test
• ICEA T-29-520 (210,000
BTU/hr) Vertical Flame Test
• ICEA T-30-520 (70,000BTU/hr) Vertical Flame Test
*Refer to CE Code for details
CONDUCTOR
SHIELD
OUTER JACKET
ARMOUR
CONDUCTORINSULATION
CONCENTRIC COPPER
BOND CONDUCTOR
INSULATION
SHIELD
INNER JACKET
TAPE
HL
Note: All dimensions are nominal and are subject to normal manufacturing tolerance.
Specifications are subject to change without prior notice.
* See pages 30 & 31 for corresponding connector.
Non-ferrous connectors only.
Conductor: Bare copper Class B compact or compressed stranded
Conductor Shield: Extruded thermoset semi-conducting shield
Insulation: Tree-Retardant Cross-Linked Polyethylene (TR-XLPE)
Insulation Shield: Extruded thermosetting semi-conducting shield
Ground (Bonding/Shield) Conductor: Stranded bare copper conductor
Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
Armour: Aluminum Interlocked Armour (AIA)
Outer Jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
Options: Other coloured outer jacket and constructions available upon request
-
8/9/2019 Texcan Teck Medium Voltage Shielded.pdf
9/13
19026-02-012 1 6 0.320 0.990 2.530 2.820 2.940 985 1466 3690 5490 187 10/10A 10/10A
19026-03-012 1/0 6 0.320 1.030 2.650 2.940 3.060 1193 1775 4110 6120 215 10/10A 10/10A
19026-06-012 2/0 6 0.320 1.070 2.740 3.030 3.150 1460 2173 4490 6680 246 10/10A 10/10A
19026-04-012 3/0 4 0.320 1.120 2.910 3.190 3.330 1842 2741 5270 7840 283 11/11A 11/11A
19026-05-012 4/0 4 0.320 1.170 3.020 3.310 3.440 2261 3365 5840 8700 325 11/11A 11/11A
19026-08-012 250 4 0.320 1.220 3.150 3.430 3.580 2629 3912 6440 9590 359 11/11A 11/11A
19026-11-012 350 3 0.320 1.370 3.440 3.730 3.880 3615 5380 7720 11490 438 12/12A 12/12A
19026-12-012 500 2 0.320 1.454 3.625 3.865 4.035 5096 7584 9943 14797 536 12/12A 12/12A
Part
Number
AWG SizeInsulation
Thickness
(in.)
Approximate
Diameter (Over)
Copper
ContentNet Weightw/ Armour Amp.
(40°CAmbient)
Recommended
Connector*
Cond.BondWire
Insul.(in.)
InnerJacket
(in.)
Armour(in.)
OuterJacket
(in.)
LB/MFT
KG/KM
LB/MFT
KG/KM TMC2 TMC2X
Teck 90 Armoured Power
Universal Toll Free Phone: 1.877.777.5776 | 23
S PE CIFI C AT IO NS CONST RUC TI ON
Shielded Three Conductor320 MIL 133% 25kV
TR-XLPE/PVC/AIA/PVC
• CSA FT1 & FT4
• CSA C22.2 No. 131 & 174
• CSA C68.3
• IEEE 383 & 1202 (70,000BTU/hr) Flame Test
• ICEA T-29-520 (210,000
BTU/hr) Vertical Flame Test
• ICEA T-30-520 (70,000BTU/hr) Vertical Flame Test
*Refer to CE Code for details
HL
Note: All dimensions are nominal and are subject to normal manufacturing tolerance.
Specifications are subject to change without prior notice.
* See pages 30 & 31 for corresponding connector.
Conductor: Bare copper Class B compact or compressed stranded
Conductor Shield: Extruded thermoset semi-conducting shield
Insulation: Tree-Retardant Cross-Linked Polyethylene (TR-XLPE)
Insulation Shield: Extruded thermosetting semi-conducting shield
Metallic Shield: Helically applied 15% gapped copper tape
Ground (Bonding) Conductor: Stranded bare copper conductor
Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
Armour: Aluminum Interlocked Armour (AIA)
Outer Jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
Options: Galvanized Steel Interlocked Armour (GSIA)
Other coloured outer jacket and constructions available upon requestHelically applied 20% overlapped copper tape shield
INSULATION
BOND
CONDUCTOR
CONDUCTOR
SHIELD
OUTER JACKET
ARMOUR
FILLERS
INNER JACKET
CONDUCTOR
COPPER
TAPE
INSULATION
SHIELD
TAPE
-
8/9/2019 Texcan Teck Medium Voltage Shielded.pdf
10/13
Part
Number
AWG SizeInsulation
Thickness
(in.)
Approximate
Diameter (Over)
Copper
ContentNet Weightw/ Armour Amp.
(40°CAmbient)
Recommended
Connector*
Cond.BondWire
Insul.(in.)
InnerJacket
(in.)
Armour(in.)
OuterJacket
(in.)
LB/MFT
KG/KM
LB/MFT
KG/KM TMC2 TMC2X
19031-02-012 1 4 0.345 1.035 1.385 1.625 1.735 387 576 2477 3686 140 6A/7 6A/7
19031-03-012 1/0 4 0.345 1.076 1.465 1.705 1.815 453 674 1565 2329 159 6A/7 6A/7
19031-04-012 2/0 4 0.345 1.116 1.505 1.745 1.855 538 801 1841 2740 181 7/7A 7/7A
19031-05-012 3/0 3 0.345 1.160 1.525 1.765 1.875 678 1009 1982 2950 205 7/7A 7/7A
19031-06-012 4/0 3 0.345 1.215 1.605 1.845 1.955 818 1217 2204 3280 232 7/7A 7/7A
19031-08-012 250 2 0.345 1.255 1.645 1.885 1.995 975 1451 2397 3567 253 8A 8A/8B
19031-10-012 350 1 0.345 1.365 1.850 2.090 2.200 1343 1999 3058 4551 302 8A 8A/8B
19031-12-012 500 1/0 0.345 1.506 1.990 2.230 2.340 1868 2780 3729 5549 360 9/9A 9/9A/9B
19031-14-012 750 2/0 0.345 1.620 2.105 2.345 2.485 2723 4052 4758 7081 434 9/9A 9/9A/9B
19031-15-012 1000 2/0 0.345 1.810 2.280 2.520 2.660 3491 5195 5740 8542 486 9/9A 9/9A/9B
Teck 90 Armoured Power
24 | Universal Toll Free Phone: 1.877.777.5776
C ON T R OL S H I E L D E D
SPE CI FIC AT IONS CO NST RU C T IO N
Shielded Single Conductor345 MIL 133% 28kV
TR-XLPE/PVC/AIA/PVC
• CSA FT1 & FT4
• CSA C22.2 No. 131 & 174
• CSA C68.3
• IEEE 383 & 1202 (70,000BTU/hr) Flame Test
• ICEA T-29-520 (210,000
BTU/hr) Vertical Flame Test
• ICEA T-30-520 (70,000BTU/hr) Vertical Flame Test
*Refer to CE Code for details
CONDUCTOR
SHIELD
OUTER JACKET
ARMOUR
CONDUCTORINSULATION
CONCENTRIC COPPER
BOND CONDUCTOR
INSULATION
SHIELD
INNER JACKET
TAPE
HL
Note: All dimensions are nominal and are subject to normal manufacturing tolerance.
Specifications are subject to change without prior notice.
* See pages 30 & 31 for corresponding connector.
Non-ferrous connectors only.
Conductor: Bare copper Class B compact or compressed stranded
Conductor Shield: Extruded thermoset semi-conducting shield
Insulation: Tree-Retardant Cross-Linked Polyethylene (TR-XLPE)
Insulation Shield: Extruded thermosetting semi-conducting shield
Ground (Bonding/Shield) Conductor: Stranded bare copper conductor
Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
Armour: Aluminum Interlocked Armour (AIA)
Outer Jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
Options: Other coloured outer jacket and constructions available upon request
-
8/9/2019 Texcan Teck Medium Voltage Shielded.pdf
11/13
Part
Number
AWG SizeInsulation
Thickness
(in.)
Approximate
Diameter (Over)
Copper
ContentNet Weightw/ Armour Amp.
(40°CAmbient)
Recommended
Connector*
Cond.BondWire
Insul.(in.)
InnerJacket
(in.)
Armour(in.)
OuterJacket
(in.)
LB/MFT
KG/KM
LB/MFT
KG/KM TMC2 TMC2X
19027-01-012 1 6 0.345 1.040 2.680 2.970 3.100 988 1470 3980 5930 187 10/10A 10/10A
19027-02-012 1/0 6 0 .345 1.080 2.760 3.050 3.180 1200 1786 4360 6490 215 10/10A 10/10A
19027-03-012 2/0 6 0.345 1.120 2.920 3.210 3.360 1466 2182 4950 7370 246 11/11A 11/11A
19027-04-012 3/0 4 0 .345 1.170 3.020 3.310 3.460 1848 2750 5490 8160 283 11/11A 11/11A
19027-05-012 4/0 4 0 .345 1.220 3.140 3.430 3.580 2264 3369 6090 9060 325 11/11A 11/11A
19027-06-012 250 4 0.345 1.270 3.260 3.550 3.700 2635 3921 6660 9910 359 11/11A 11/11A
19027-08-012 350 3 0.345 1.420 3.560 3.850 4.000 3621 5389 7960 11840 438 12/12A 12/12A
19027-10-012 500 2 0.345 1.506 3.740 3.900 4.150 2893 3980 8008 11917 536 12/12A 12/12A
Teck 90 Armoured Power
Universal Toll Free Phone: 1.877.777.5776 | 25
S PE CIFI C AT IO NS CONST RUC TI ON
Shielded Three Conductor345 MIL 133% 28kV
TR-XLPE/PVC/AIA/PVC
• CSA FT1 & FT4
• CSA C22.2 No. 131 & 174
• CSA C68.3
• IEEE 383 & 1202 (70,000BTU/hr) Flame Test
• ICEA T-29-520 (210,000
BTU/hr) Vertical Flame Test
• ICEA T-30-520 (70,000BTU/hr) Vertical Flame Test
*Refer to CE Code for details
HL
Note: All dimensions are nominal and are subject to normal manufacturing tolerance.
Specifications are subject to change without prior notice.
* See pages 30 & 31 for corresponding connector.
Conductor: Bare copper Class B compact or compressed stranded
Conductor Shield: Extruded thermoset semi-conducting shield
Insulation: Tree-Retardant Cross-Linked Polyethylene (TR-XLPE)
Insulation Shield: Extruded thermosetting semi-conducting shield
Metallic Shield: Helically applied 15% gapped copper tape
Ground (Bonding) Conductor: Stranded bare copper conductor
Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
Armour: Aluminum Interlocked Armour (AIA)
Outer Jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
Options: Galvanized Steel Interlocked Armour (GSIA)Other coloured outer jacket and constructions available upon request
Helically applied 20% overlapped copper tape shield
INSULATION
BOND
CONDUCTOR
CONDUCTOR
SHIELD
OUTER JACKET
ARMOUR
FILLERS
INNER JACKET
CONDUCTOR
COPPER
TAPE
INSULATION
SHIELD
TAPE
-
8/9/2019 Texcan Teck Medium Voltage Shielded.pdf
12/13
CONDUCTOR
SHIELD
OUTER JACKET
ARMOUR
CONDUCTORINSULATION
CONCENTRIC COPPER
BOND CONDUCTOR
INSULATION
SHIELD
INNER JACKET
TAPE
Part
Number
AWG SizeInsulation
Thickness
(in.)
Approximate
Diameter (Over)
Copper
ContentNet Weightw/ Armour Amp.
(40°CAmbient)
Recommended
Connector*
Cond.BondWire
Insul.(in.)
InnerJacket
(in.)
Armour(in.)
OuterJacket
(in.)
LB/MFT
KG/KM
LB/MFT
KG/KM TMC2 TMC2X
19030-02-010 1/0 4 0.345 1.076 1.465 1.705 1.815 453 674 1565 2329 159 6A/7 6A/7
19030-03-010 2/0 4 0.345 1.116 1.505 1.745 1.885 538 801 1841 2740 181 7/7A 7/7A
19030-04-010 3/0 3 0.345 1.160 1.525 1.765 1.875 678 1009 1982 2950 205 7/7A 7/7A
19030-05-010 4/0 3 0.345 1.215 1.605 1.845 1.955 818 1217 2204 3280 232 7/7A 7/7A
19030-06-010 250 2 0.345 1.255 1.645 1.885 1.995 975 1451 2397 3567 253 8/8A 8/8A/8B
19030-08-010 350 1 0.345 1.365 1.850 2.090 2.200 1343 1999 3058 45511 302 8A 8A/8B
19030-10-010 500 1/0 0.345 1.506 1.990 2.230 2.340 1868 2780 3729 5549 360 9/9A 9/9A/9B
19030-12-010 750 2/0 0.345 1.620 2.105 2.345 2.485 2723 4052 4758 7081 434 9/9A 9/9A/9B
19030-15-010 1000 2/0 0.345 1.810 2.280 2.520 2.660 3491 5195 5740 8542 486 9/9A 9/9A/9B
Teck 90 Armoured Power
26 | Universal Toll Free Phone: 1.877.777.5776
C ON T R OL S H I E L D E D
SPE CI FIC AT IONS CO NST RU C T IO N
Shielded One Conductor345 MIL 100% 35kV
TR-XLPE/PVC/AIA/PVC
• CSA FT1 & FT4
• CSA C22.2 No. 131 & 174
• CSA C68.3
• IEEE 383 & 1202 (70,000BTU/hr) Flame Test
• ICEA T-29-520 (210,000
BTU/hr) Vertical Flame Test
• ICEA T-30-520 (70,000BTU/hr) Vertical Flame Test
*Refer to CE Code for details
HL
Note: All dimensions are nominal and are subject to normal manufacturing tolerance.
Specifications are subject to change without prior notice.
* See pages 30 & 31 for corresponding connector.
Non-ferrous connectors only.
Conductor: Bare copper Class B compact or compressed stranded
Conductor Shield: Extruded thermoset semi-conducting shield
Insulation: Tree-Retardant Cross-Linked Polyethylene (TR-XLPE)
Insulation Shield: Extruded thermosetting semi-conducting shield
Ground (Bonding/Shield) Conductor: Stranded bare copper conductor
Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
Armour: Aluminum Interlocked Armour (AIA)
Outer Jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
Options: Other coloured outer jacket and constructions available upon request
-
8/9/2019 Texcan Teck Medium Voltage Shielded.pdf
13/13
Part
Number
AWG SizeInsulation
Thickness
(in.)
Approximate
Diameter (Over)
Copper
ContentNet Weightw/ Armour Amp.
(40°CAmbient)
Recommended
Connector*
Cond.BondWire
Insul.(in.)
InnerJacket
(in.)
Armour(in.)
OuterJacket
(in.)
LB/MFT
KG/KM
LB/MFT
KG/KM TMC2 TMC2X
19028-02-010 1/0 6 0.345 1.080 2.760 3.050 3.180 1200 1786 4360 6488 215 10/10A 10/10A
19028-03-010 2/0 6 0.345 1.120 2.920 3.210 3.360 1466 2182 4950 7366 246 11/11A 11/11A
19028-04-010 3/0 4 0.345 1.170 3.020 3.310 3.460 1848 2750 5490 8170 283 11/11A 11/11A
19028-05-010 4/0 4 0.345 1.220 3.140 3.430 3.580 2264 3369 6090 9063 325 11/11A 11/11A
19028-06-010 250 4 0.345 1.270 3.260 3.550 3.700 2635 3921 6660 9911 359 11/11A 11/11A
19028-08-010 350 3 0.345 1.420 3.560 3.850 4.000 3621 5389 7960 11846 438 12/12A 12/12A
19028-11-010 500 3 0.345 1.510 3.740 3.980 4.250 2893 4305 8006 11914 536 12/12A 12/12A
Teck 90 Armoured Power
Universal Toll Free Phone: 1.877.777.5776 | 27
S PE CIFI C AT IO NS CONST RUC TI ON
Shielded Three Conductor345 MIL 100% 35kV
TR-XLPE/PVC/AIA/PVC
• CSA FT1 & FT4
• CSA C22.2 No. 131 & 174
• CSA C68.3
• IEEE 383 & 1202 (70,000BTU/hr) Flame Test
• ICEA T-29-520 (210,000
BTU/hr) Vertical Flame Test
• ICEA T-30-520 (70,000BTU/hr) Vertical Flame Test
*Refer to CE Code for details
HL
Note: All dimensions are nominal and are subject to normal manufacturing tolerance.
Specifications are subject to change without prior notice.
* See pages 30 & 31 for corresponding connector.
Conductor: Bare copper Class B compact or compressed stranded
Conductor Shield: Extruded thermoset semi-conducting shield
Insulation: Tree-Retardant Cross-Linked Polyethylene (TR-XLPE)
Insulation Shield: Extruded thermosetting semi-conducting shield
Metallic Shield: Helically applied 15% gapped copper tape
Ground (Bonding) Conductor: Stranded bare copper conductor
Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
Armour: Aluminum Interlocked Armour (AIA)
Outer Jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
Options: Galvanized Steel Interlocked Armour (GSIA)
Other coloured outer jacket and constructions available upon requestHelically applied 20% overlapped copper tape shield