M-2002
Since 1918…
Call Toll-Free 1-800-ERICSON (374-2766)
24
Incandescent Hand LampsFluorescent Hand Lamps
Wide Area Fluorescent LightingWide Area High Pressure Sodium and Metal Halide
Vapor proof Hand LampsLow Voltage Hand Lamps
Low Voltage Transformers & Extension LightsHazardous Duty Hand lamps
Emergency Response Lighting KitFlashlights
String Lights
Incandescent Hand LampsFluorescent Hand Lamps
Wide Area Fluorescent LightingWide Area High Pressure Sodium and Metal Halide
Vapor proof Hand LampsLow Voltage Hand Lamps
Low Voltage Transformers & Extension LightsHazardous Duty Hand lamps
Emergency Response Lighting KitFlashlights
String Lights
Incandescent Hand LampsFluorescent Hand Lamps
Wide Area Fluorescent LightingWide Area High Pressure Sodium and Metal Halide
Vapor proof Hand LampsLow Voltage Hand Lamps
Low Voltage Transformers & Extension LightsHazardous Duty Hand lamps
Emergency Response Lighting KitFlashlights
String Lights
25
Temporary LightingIntroduction
Visit Our Website at www.ericson.com
Ericson Manufacturing Company engineers and produces a comprehensive range of temporary lighting products
for your general maintenance, confined space, hazardous location and wide area lighting needs. These products elimi-
nate poorly lit areas that create safety hazards and help your company comply with the NEC and OSHA regulations. In
the following pages you will find:
• Task Lighting: Incandescent and fluorescent handlamps
• Wide Area Lighting: High-pressure sodium, metal halide and fluorescent wide area lighting products.
• Specialty Lighting: Hazardous Location, Low Voltage and Vapor proof
• Stringlights:Temporary Lighting strings for commercial and industrial applications
• Flashlights: From hazardous duty to general maintenance
• Easy to use charts and drawings simplify the selection/specification process making it quick and user friendly
• Technical reference information including dimensional drawings
Task Lighting - Incandescent and Fluorescent Hand Lamps• UL Listed and CSA Certified
• Available with a variety of cord types and lengths
• Full range of replacement parts are available for your field service repair work
Wide Area Lighting – Fluorescent, High Pressure Sodium & Metal Halide• UL Listed and CSA Certified
• Energy efficient
• Bright, wide area illumination
Vapor proof, Low Voltage & Hazardous Duty Hand Lamps• UL Listed and CSA Certified
• Incandescent & fluorescent hazardous location handlamps
• Available in a variety of standard and custom assemblies
• Can be used for confined space entry work
Flashlights• Variety of models for applications from hazardous duty to general maintenance work
Custom Built DevicesAs always you can turn to Ericson Manufacturing Company to engineer a solution to your temporary lighting applica-
tion if you do not find a standard catalog item to fit your need. Contact the factory or your local sales representative
to find out more.
26
Temporary LightingIndustrial Duty Incandescent Handlamps
Call Toll-Free 1-800-ERICSON (374-2766)
700 Series - No side outlet
Material• Handle: Rubber• Lampholder/Cord Entry Seal: Rubber• Screwshell: Tin plated brass• Warning label: UL approved polyester• Product label: UL approved polyester• Lamp Guard Plating: Zinc chromate
Electrical• Operating voltage: 120V• Frequency: 60Hz
Mechanical• Color: Yellow • Cord Types: SOW
Environmental• Operating Temperature Range: -35C to +66C• Flammability: UL94V-0
Listings• UL Listed• CSA Certified
SPECIFICATIONS
CERTIFIED
• UL Listed and CSA Certified• Molded rubber handle impervious to impact
and resistant to jobsite chemicals• Available with optional switch• Wide selection of pre-wired handlamps and component parts• Ericson’s exclusive Safety Yellow and Orange color combination
for easy identification• Prewired models come with #16/3 SOW cord and Ericson’s
1510-PG Perma-GripTM plug
• UL Listed and CSA Certified• Molded rubber handle impervious to impact
and resistant to jobsite chemicals• Standard with NEMA 5-15 side outlet• Available with optional switch• Wide selection of pre-wired handlamps and
component parts• Ericson’s exclusive Safety Yellow and Orange color
combination for easy identification• Prewired models come with #16/3 SOW cord
and Ericson’s 1510-PG Perma-GripTM plug
27
Temporary LightingIndustrial Duty Incandescent Handlamps
Visit Our Website at www.ericson.com
900 Series - With side outlet
Material• Handle: Rubber• Lampholder/Cord Entry Seal: Rubber• Screwshell: Tin-plated brass• Warning label: UL approved polyester• Product label: UL approved polyester• Lamp Guard Plating: Zinc-chromate• Side Outlet: NEMA 5-15
Electrical• Operating voltage: 120V• Frequency: 60Hz
Mechanical• Color: Yellow • Cord Types: SOW
Environmental• Operating Temperature Range: -35C to +66C• Flammability: UL94V-0
Listings• UL Listed• CSA Certified
SPECIFICATIONS
CERTIFIED
700 Series
Handlamp Handles w/Guard Open-endCord Closed-end Closed-end Open-end Open-end 100 watt PAR 38
Reflector Switch Length 75-100 watt 200-300 watt 100-150 watt 200-300 watt or 300 watt Type R
No No N/A 744 718 747 719 750Yes No N/A 744-R 718-R 747-R 719-R N/AYes Yes N/A 744-RS 718-RS 747-RS 719-RS N/ANo Yes N/A 744-S 718-S 747-S 719-S 750-S
Pre-Wired Models with #16/3 SOW cord and NEMA 5-15 PlugNo No 25’ 7425 (SEE NOTES)
Yes No 25’ 7425-R (SEE NOTES)
No No 50’ 7450 (SEE NOTES)
Yes No 50’ 7450-R (SEE NOTES)
Specifications:Electrical Ratings 120V, 60HzCord Size/# Conductors #16/3Cord Type SOWPlug NEMA 5-15
28
Temporary Lighting700 & 900 Series Incandescents
Call Toll-Free 1-800-ERICSON (374-2766)
Notes:1. Consult factory for custom assemblies2. Bulbs are not furnished with handlamps3. All guards have a 1-3/4” collar and fit 600, 700 and 900 Series incandescent handlamps4. Vinyl insulated guards available: Add ”I” to catalog number to specify. Example: 718-R becomes 718-RI5. Switch available: Add “S” to catalog Number to specify. Example 7425-R becomes 7425-RS6. Available with in-line and plug-type GFCIs. Add “GF” to catalog number for in-line GFCI
Example: 7425-GF; or GP for plug-type GFCI. Example: 7425 -GP
Socket, Ground Clip & Switch for use with700 Series Handles 900 Series Handles 700 and 900 Series Handles
Socket Ground Clip SwitchNo Switch With Switch No Switch With Switch w/ 6” leads w/ leadHandle Only7 7-S 9 9-S 44-W 710 79Handle Assembly (with socket & ground clip)7-A 7-SA 9-A 9-SA
Replacement parts
900 Series
Closed-end Closed-end Open-end Open-end75-100 watt 200-300 watt 100-150 watt 200-300 watt
944 918 947 919944-R 918-R 947-R 919-R944-RS 918-RS 947-RS 919-RS944-S 918-S 947-S 919-S
9425 (SEE NOTES)
9425-R (SEE NOTES)
9450 (SEE NOTES)
9450-R (SEE NOTES)
120V, 60Hz#16/3SOWNEMA 5-15
29
Temporary Lighting700 & 900 Series Incandescents
Visit Our Website at www.ericson.com
Outside Diameter 3-7/8” 4-1/16” 5-5/16” 5-5/16” 6-7/16”Overall Length 6-1/2” 6-7/8” 8-1/4” 8-5/8” 7-5/8”
No Reflector 104 107 118 119 150With Reflector 104-R 107-R 118-R 119-R N/A
Notes:1. All guards have a 1-3/4” collar and fit 600, 700 and 900 Series handlamps2. Vinyl insulated guards available: Add ”I” to catalog number to specify. Example: 104-R becomes 104-RI
Lamp Guards for 600, 700 and 900 Series Handlamps
30
Temporary LightingLamp Guards for 600, 700 & 900 Hand Lamps
Call Toll-Free 1-800-ERICSON (374-2766)
Ø3-7/8”
15-7/8”
13”
8”
744R Series
31
Temporary LightingNotes
Visit Our Website at www.ericson.com
Call Toll-Free 1-800-ERICSON (374-2766)
32
Temporary LightingIncandescent Handlamps
Light to Medium Duty Incandescent Handlamps: 600 and 2900 Series
600 Series Hand Lamps• UL Listed and CSA Certified• Compact, portable, durable and versatile.• Handle constructed of high-impact,
chemical resistant thermoplastic• High-Visibility safety yellow color for
easy jobsite identification• Elastomeric gaskets protects cord entry
and lampholder & seals out jobsite contaminants
• Snap-open guard makes relampingeasy – no tools required
For many applications the 2900 and 600 Series hand lamps offer an economical alternative and provide value-added per-formance. Typical applications include general maintenance, construction, remodeling, demolition and repair work.
2900 Series Hand Lamps• UL Listed and CSA Certified• Lightweight and compact • Handle constructed of high-
impact yellow nylon• Includes switch• Available in 25’ and 50’ cord lengths
with molded on NEMA 5-15 plug
NEW!
33
Temporary LightingIncandescent Handlamps
Visit Our Website at www.ericson.com
600 and 2900 Series Handlamps Selection Guide
600 Series 2900 Serieswith 25’ cord 6425-RS 2925with 50’ cord 2950
Specifications:Electrical Ratings 120V, 60Hz 120V, 60HzMax. Wattage 100 watt 100 wattCord Size/# Conductors #16/3 #16/3Cord Type SJTW SJTWPlug Molded NEMA 5-15 plug Molded NEMA 5-15 plugSwitch Yes YesOutlet in Handle Yes (NEMA 5-15) Yes (NEMA 5-15)Reflector Guard Yes YesSwing Open Guard Yes YesSwivel Hook Yes Yes
2.3
6.82
15.13
600 Series
800 Series Mini and Maxi-Lite Selection Guide
8-watt Mini-Lite 15-watt Maxi-Litewith 14’ coiled cord 802-14with 25’ cord 801-25
Specifications:Electrical Ratings 120V, 60Hz 120V, 60HzReplacement lamp F8T5-CW F15T5-CWBallast Location Cord Integral with plugPlug NEMA 5-15 NEMA 5-15Switch No YesOverall Length 15 26Max. O.D. 1-1/4 2-1/8Weight 3 lbs. 2.5 lbs.
34
Temporary Lighting800 Series Mini-Lite & Maxi-Lite Fluorescent Handlamps
Call Toll-Free 1-800-ERICSON (374-2766)
Light-Medium Duty Fluorescent Handlamps• 800 Series Mini & Maxi-Lite Fluorescent Handlamps• Cool glare-free light ideal for close-up work• Fluorescent tube protected by clear butyrate lens• Lamp secured by shock-absorbing retainers• Flexible hook for easy positioning• Shatter-resistant plastic housing
35
Temporary LightingCommercial Duty Handlamps
Visit Our Website at www.ericson.com
500 Series Pivot Lights• Unique pivot provides 8 light positions to direct
the light where you need it most• Base magnet and flexible hook allow easy mounting to a variety of surfaces• NEMA 5-15 power outlet in handle provides
convenient power source for other tools• 13 watt fluorescent bulb provides same light output as
60 watt incandescent without the intense heat• Scratch and shatter resistant lens• Oil and water resistant power cord• Also available in a DC version
300 Series Conversion Lights• Unique base converts any hot, dangerous incandescent
light into a cool-running fluorescent light• Also available with NEMA 5-15 power inlet
that plugs into your extension cord• Compact and easy to carry• Large, shock-absorbing easy grip end caps• Scratch and shatter resistant lens
200 Series Tube Lights• Lightweight, multi-use work lights• Large, shock-absorbing easy grip end caps• Available in 13 watt and 15 watt models• Scratch and shatter resistant lens• Oil and water resistant power cords, 25’ and 50’ lengths
Commercial Duty Handlamps: 200, 300, 400 & 500 SeriesEricson is lighting the new millennium with its brand new line of task lighting.• UL Listed and CSA Certified• Compact, portable, durable and versatile.• Handle constructed of high-impact, chemical resistant thermoplastic• High-Visibility safety yellow color for easy jobsite identification• Variety of different models available to fit your application: The Conversions™ which convert your incandescent
handlamp into a cool-running fluorescent handlamp or try the model that plugs into your extension cord, also available is DC fluorescent handlamp that can be powered from your vehicle’s battery or portable DC power source.
400 Series Angle Lights• Unique angle-design directs the light right where you need it most• Cool running ballast-in-handle provides well-balanced
light that is easy to handle• NEMA 5-15 power outlet in handle provides
convenient power source for other tools• 13-watt fluorescent bulb provides same light output
as 60 watt incandescent without the intense heat• Scratch and shatter resistant lens• Provided with magnet and hook for easy mounting• Oil and water resistant power cords, 25’and 50’ lengths• Also available in a DC version
NEW!
36
Temporary LightingCommercial Duty Handlamps
Call Toll-Free 1-800-ERICSON (374-2766)
200 Series Tube Lites 300 Series Conversion(1) Lights13-watt 15-watt Screwshell
with 25’cord 213-25 215-25 313-MBwith 50’cord 213-50 215-50
Electrical Ratings 120V, 60Hz 120V, 60Hz 120V, 60HzCord Size/# Conductors #18/2 #18/2 N/ACord Type SJTOW SJTOW N/ABallast Location Cord Cord HandlePower Inlet Molded NEMA 5-15 plug Molded NEMA 5-15 plug Medium base screwshellPower Outlet
Power Outlet RatingOther On/Off switch On/Off switch
in handle in handleNotes:1. Conversion lights do not come with cord2. Contact factory for availability of DC lights
200, 300, 400 & 500 Series Handlamps Selection GuideNEW!
200 Series 300 Series
37
Temporary LightingCommercial Duty Handlamps
Visit Our Website at www.ericson.com
300 Series Conversion(1) Lights 400 Series Angle Lights 500 Series Pivot LightsExtension Cord 13-watt AC 13-watt DC 13-watt AC 13-watt DC313-P 413-25 413DC-15 513-25 513DC-15
120V, 60Hz 120V, 60Hz 12VDC 120V 60HZ 12VDCN/A #16/3 #18/2 #16/3 #18/2N/A SJTOW SPT2 SJTOW SPT2Handle Handle Handle Base BaseNEMA 5-15 Molded NEMA 5-15 plug 5-15
(1) NEMA 5-15120V, 13Amps
Plugs intoPlugs into cigarette lighter cigarette lighter
300 Series 400 Series 500 Series
Pivot action!
38
Temporary LightingIndustrial Duty Fluorescent Handlamps
Call Toll-Free 1-800-ERICSON (374-2766)
Ericson’s Portable Fluorescent Hand Lamps are ruggedly constructed for service in industrialapplications, construction, shipbuilding, public utilities, paper mills, food processing, chemicalplants and others where a rugged cool, non-glare lamp is needed.
Features• Cool, Glare-Free Light - Perfect for those close-up jobs where hot, glaring light can be a hazard• Variety - Available with or without switch, with factory wired cordsets or power inlets so
you can use your own extension cord• Flush, Molded Switch Cover (926 series) - Switch is flush with and completely sealed inside handle — won’t snag
on jobsite obstacles and is protected from the environment• Field Serviceable - Field repairs are quick and convenient with wide range of replacement parts• Bright, Diffuse Illumination • Energy Efficient - Significant savings over operating costs of incandescent lamps• Durability - Impact resistant lens with rubber end-cap and handle for the toughest industrial jobs. Resistant to many
jobsite oils and chemicals. Lamp retainers secure bulb in place to withstand jobsite use without breaking• Weather Resistant Construction - Designed for applications requiring weather-resistant construction• Reliability - Engineered to perform in demanding industrial and construction environments. Rated lamp life of 10,000
hours for maximum time between bulb replacements• Safety - All non-metallic construction eliminates possibility of housing becoming energized• Lightweight - Ergonomic design fits comfortably in your hand providing a well-balanced work light easy to use
during long projects• Cord Grip - Industry proven cord grip provides strain relief and seals out water, dust and other jobsite contaminants• High Visibility - Safety yellow and orange for easy identification
15-watt 30-watt 13-watt 26-wattwith 25’ cord 815-25 830-25 900-25 926-25with 50’ cord 815-50 830-50 900-50 926-50
Specifications:Initial Lumens 825 2175 900 1700Electrical Ratings 120V, 60Hz 120V, 60Hz 120V, 60Hz 120V, 60HzBallast Location Cord Cord Cord HandlePower Inlet NEMA 5-15 plug NEMA 5-15 plug NEMA 5-15 plug NEMA 5-15 plugSwitch No No No In-Handle
Replacement PartsEnd cap with hook 901 926-ECTube shield 902 926-TSLamp (bulb) 903 926-CFLamp retaining spider 904 926-RSHandle with ballast and 25’ cord 905Handle with ballast and 50’ cord 906Ballast kit 926-BP
Notes:1. Consult factory for custom assemblies
800 & 900 Series Fluorescent Hand Lamps Selection Guide
39
Temporary LightingIndustrial Duty Fluorescent Handlamps
Visit Our Website at www.ericson.com
26-watt926NS-25 926-P 926NS-P 926-PL 926NS-PL926NS-50
1700 1700 1700 1700 1700120V, 60Hz 120V, 60Hz 120V, 60Hz 120V, 60Hz 120V, 60HzHandle Handle Handle Handle HandleNEMA 5-15 plug NEMA 5-15 plug NEMA 5-15 plug NEMA L5-15 plug NEMA L5-15 plugNo In-Handle No In-Handle No
926-EC 926-EC 926-EC 926-EC 926-EC926-TS 926-TS 926-TS 926-TS 926-TS926-CF 926-CF 926-CF 926-CF 926-CF926-RS 926-RS 926-RS 926-RS 926-RS
926-BP 926-BP 926-BP 926-BP 926-BP
815/830 Series 900 Series
926 Series
25.63 (815 Series) 42.75 (830 Series)
18.50 in.
5.25 in.
6.50 in. 8.42 in.
3.75 in.
14.48
Ø2.2 Ø2.2
2.45 in. DIA 2.10 in.DIA
.63
2.00 in.DIA
P Models have NEMA 5-15Power Inlet
PL Models have NEMA L5-15Power Inlet
40
Temporary LightingWide Area Lighting
Call Toll-Free 1-800-ERICSON (374-2766)
1100 and 1200 Series Wide Area LightingThese portable overhead lights have been engineered to meet the need for safe, temporary, economical lighting for large area.Their versatility provides for base unit and feed-through unit use to meet virtually any wide area lighting requirement. Heavy-dutyconstruction and high lumen output make these lights ideal for a broad range of applications including manufacturing plants,airline maintenance hangers, ship building, food processing plants, utilities, breweries, general maintenance and construction plus many more. The 1100 Series uses standard fluorescent tubes while the 1200 Series uses long-life biaxial tubes for a smaller unit where space is major concern.
• Overhead fluorescent lighting designed for temporary lighting in large areas• Variety of models available including feed-through units that allows you to “daisy-chain” several lights in a row• Heavy-duty construction and high lumen output• Lower operating costs versus incandescent lighting means savings for you• Industry proven cord grip provides strain relief and seals out water, dust and other jobsite contaminants• Safety yellow and orange for easy identification• Rapid start lamps• Available with 30 or 40 watt fluorescent lamps• Impact resistant tube-shield• Moisture and dust resistant construction seals out contaminants• One inch wide nylon straps serve as heavy duty hangers and are flexible and adjustable• Each hanger comes with nickel-plated heavy gauge hook for corrosion resistance
1100 & 1200 Series Selection Guide
1100 Series 1200 SeriesTotal Fixture Wattage: 30 watts 60 watts 80 watts 36 watts 54 watts 78 wattsBase Units
25 ft. Primary 1115-25 1130-25 1140-25 1218-25 1227-25 1239-25Feed-Through Units
2.5 ft. Primary 1115-2F 1218-2F4 ft. Primary 1130-4F 1140-4F 1227-4F 1239-4F25 ft. Primary 1115-25F 1130-25F 1140-25F 1218-25F 1227-25F 1239-25FMax. Units 10 13 12 13 13 12Minimum start temperature (° F) 60 60 60 60 60 60
Specifications:Initial Lumens 1650 4400 5000 2500 3600 5700Electrical 120V/60Hz 120V/60Hz 120V/60Hz 120V/60Hz 120V/60Hz 120V/60HzReplacement Lamp - 2 Per Fixture F15T8/CW F30T12/CW RS F40T12/CW RS F18BX/SPX35 RS F27BX/SPX35 F39BX/SPX35Avg. Rated Lamp Life (hrs) 7500 18000 20000 20000 12000 12000Weight (lbs)
Base units (25’primary) 11lbs 19lbs 23lbs 10lbs 10lbs 11lbsFeed-Through units
2.5’pri 9lbs 8lbs4 ft. pri 18lbs 22lbs 9lbs 10lbs
Primary Cord #16/3 SJOW #16/3 SJOW #16/3 SJOW #16/3 SJOW #16/3 SJOW #16/3 SJOWPlug
Base units (Perma-Link device) NEMA 5-15 NEMA 5-15Feed-Through units (Perma-Tite) NEMA 5-15 NEMA 5-15 NEMA 5-15 NEMA 5-15
ConnectorBase units (Perma-Link device) NEMA 5-15 NEMA 5-15Feed-Through units (Perma-Tite) NEMA 5-15 NEMA 5-15 NEMA 5-15 NEMA 5-15
Contact Factory for Custom Assemblies
1115-25 Base unit
Feed-thru unit Feed-thru unit
1218-25 Base unit
41
Temporary LightingWide Area Lighting
Visit Our Website at www.ericson.com
1100 Series
1200 Series
1100 Series 1200 Series30 watts 60 watts 80 watts 36 watts 54 watts 78 watts
Tubeshield 1115-TS 1130-TS 1140-TS 1218-TS 1227-TS 1239-TSReplacement Fluorescent Tube 1218-FT 1227-FT 1239-FT
End cap with cord grip bushing for 1100-P 1100-P1100 & 1200 Series. Can be usedfor primary side and secondary sidewith feed through
End cap less cord grip bushing for 1100-S 1100-S1100 and 1200 Series. Can be usedfor secondary side of base units only
Replacement Parts
39 IN. REF.
6.55
3.50
8.20
3.50 8.20
15 1/2 IN.
Call Toll-Free 1-800-ERICSON (374-2766)
42
• Available with or without Receptacle and Ground Fault Circuit Interrupter
• Versatile• Energy Efficient
Temporary LightingHigh Pressure Sodium & Metal Halide Wide Area Lighting
1000 Series High Pressure Sodium Wide Area Lighting• UL listed to North American and Canadian standards• Impact-resistant molded polycarbonate housing• Impact-resistant, high temperature clear lens with Blondel Prisms on inner surface to provide optimum light diffusion• Available with a 70 watt high-pressure-sodium• Dual magnets for secure mounting on metal surfaces• Integral eye-hook for overhead mounting• #14/3 SOW cord supplied standard• HPS model available with optional receptacle, GFCI or both• Supplied with lamp
Notes:1. Use secondary safety chain or cable if mounted overhead
1000 Series High Pressure Sodium Fixtures Selection GuideHigh Pressure Sodium Lamps(1)
Light With 5-15 With With ReceptacleOnly Receptacle GFCI & GFCI
w/ 6’cord 1000 1000-R 1000-G 1000-RGw/ 25’cord 1000-25 1000-R25 1000-G25 1000-RG25w/ 50’cord 1000-50 1000-R50 1000-G50 1000-RG50Replacement bulb 1010 1010 1010 1010
Note: Use Secondary Chain OrCable If Mounted Overhead.
Dual Magnet Mounting System for mounting
on metal surfaces
Optional Ground Fault Circuit Interrupter with
Perma-Tite Flip-Seal Cover
Optional Receptaclewith Perma-TiteFlip-Seal Cover
43
Temporary LightingHigh Pressure Sodium & Metal Halide Wide Area Lighting
Visit Our Website at www.ericson.com
6.25
8.28
9.25
1000 Series High Pressure Sodium Fixture
1000 Series Metal Halide
Metal Halide Lamp(1)
w/ 6’cord 1000-MHReplacement bulb 1010-MH
Notes:1. Use secondary safety chain or cable if mounted overhead
1000 Series Metal Halide Selection Guide
1000 Series Metal Halide Wide Area Lighting• UL listed• Lightweight die cast aluminum housing• Impact resistant, high temperature clear lens with blondel prisms on inner surface to provide optimum light diffusion• 70-watt metal halide bulb provides bright white light for color rendering applications• Heavy-duty magnet provides for secure mounting on metal surfaces• Handle with integral “eye”for overhead mounting• 6’ long, #14/3 SJTOW cord with molded 5-15 plug supplied with lamp
Specifications: High Pressure Sodium Metal HalideElectrical Ratings 120V/60Hz 120V/60HzCord Gauge #14/3 #14/3Cord Type SJOW SJTOWPlug Type NEMA 5-15 NEMA 5-15Bulb Wattage 70 watts 70 wattsBulb Type LU70/MED #MVR/70/U/MEDAverage Rated Bulb Life 24000 Hours 12000 hoursInitial Light Output 6400 Lumens 5600 lumensMean Light Output 5450 Lumens 3400 lumensColor Rendition Index (CRI) (1) 22 75Color Temperature (K) (2) 1900 K 4000 KLow Temperature Start -40 C/-40 F
Notes:1. Based on a scale from 1 to 100 where 100 represents sunlight.
The higher the number the truer the color appears2. Sunlight is simulated with a light that is about 5000 K.
The higher the number the whiter the light
Specifications - High Pressure Sodium & Metal Halide Fixtures
9.00
9.00
4.56
8.41
Ø3.66
44
Temporary LightingVapor-Gard® Handlamps
Call Toll-Free 1-800-ERICSON (374-2766)
Vapor-Gard® Handlamps: 70N Series• UL Listed and CSA Certified• Meets OSHA requirements 1926.403(g), 1926.405(j)(iii)• Meets NEC 250-59(a), 420-42(a)(b), 410-44 and 410-49• Molded thermoplastic elastomeric handle impervious
to impact and resistant to jobsite chemicals• Lampholder rated at 600 volts/660 watts• Glass globe is heat and impact resistant and threads
into handle sealing bulb and socket• Transparent polycarbonate globe available• Guard is constructed out of heavy-gauge steel wire and
finished with a Zinc-Chromate plating to resist corrosion• Optional Quik-Latch guard makes bulb changes
easy – No tools required• Cord entry provides strain relief and seals out moisture and dirt• Wide selection of pre-wired handlamps and component parts• Ericson’s exclusive Safety Yellow and Orange color combination
for easy identification• Prewired models come with #16/3 SOW cord and Ericson’s
1510-PG Perma-Grip plug
Material• Handle: Rubber• Lampholder/Cord Entry Seal: Rubber• Screwshell: Tin-plated brass• Warning label: UL approved polyester• Product label: UL approved polyester• Lamp Guard Plating: Zinc-chromate
Electrical• Operating voltage: 120V• Frequency: 60Hz
Mechanical• Color: Yellow • Cord Types: SOW
Environmental• Operating Temperature Range: -35C to +66C• Flammability: UL94V-0
Listings• UL Listed• CSA Certified
SPECIFICATIONS
Vapor-Gard Hand Lamps Are Grounded Not Available With Switch
Meet OSHA Requirements:No. 1926.403(g) No. 1926.405(j)(iii)
Meet National Electrical Code Requirements.No. 250-59(a) No. 410-44No. 410-42(a) (b) No. 410-49
45
Temporary LightingVapor-Gard® Handlamps
Visit Our Website at www.ericson.com
CatalogDescription NumberScrew-release guard, no reflector 702Screw-release guard with reflector 702-RQuik-Latch guard 703Screw-release guard, vinyl coating 704Screw-release guard w/ reflector
and vinyl coating 704-RGlass globe 707Handle only, without socket 708Socket 709
Replacement Parts
Notes:1. Consult factory for custom assemblies2. Bulbs are not furnished with handlamps3. For assemblies with GFCI protection add - GP for 1090 plug or - GF for in-line GFCI
Handlamp Handles w/Guard and Globe OnlyCord Catalog
Guard Type Reflector Length NumberScrew-Release No N/A 70-NGScrew-Release Yes N/A 70-NGRQuik-Latch No N/A 70-NGQLScrew-Release, Vinyl Insulated No N/A 70-NIScrew-Release, Vinyl Insulated Yes N/A 70-NIR
Pre-Wired Models with #16/3 SOW cord and NEMA 5-15 PlugScrew-Release 25’ 70-NG25Screw-Release 50’ 70-NG50Quik-Latch 25’ 70-NGQL25Quik-Latch 50’ 70-NGQL50
Specifications:Electrical Ratings 120V, 60HzCord Size/# Conductors #16/3Cord Type SOWPlug NEMA 5-15
70NG Series Vaporproof Handlamps
70N Series
8.98
7.55
4.25
ø2.27
Re-lamping is easy withoptional Quik-LatchTM Guard.Guard is easily removed andreplaced with thumb screw - no tools required!
46
Temporary LightingLow-Voltage Handlamps: Incandescent Series
Call Toll-Free 1-800-ERICSON (374-2766)
• Ericson’s handlamps meet OSHA regulations and create a safer working environment• Step-down transformers reduce 120VAC line voltage to 12VAC• Extra-thick walled rubber housing with non-corrosive stainless steel hardware protects transformer from jobsite contaminants• Transformers incorporate a grounded metal shield between primary and secondary windings to ensure the two voltages are
isolated providing an added degree of protection• Each transformer is subjected to a factory dielectric test of 1600 volts between primary and secondary windings and between
each winding and ground to ensure safety• High-visibility dual-color safety system for easy identification on the jobsite
Low-Voltage Handlamps:Incandescent SeriesOSHA 1926.405(a)(2)(ii)(G): “Portableelectric lighting used in wet and/or otherconductive locations, as for example,drums, tanks, and vessels, shall be operat-ed at 12 volts or less. However, 120-voltlights may be used if protected by aground-fault circuit interrupter.
Isolation Transformer
115 V GROUNDING INPUT
WEATHERPROOF COVERGROUNDED SHIELD
SECONDARY
2 WIRE OUTPUT (12V)
NEUTRAL OR (WHITE)SYSTEM GROUND
EQUIPMENT GROUND
(GREEN)
HOT (BLACK)
47
Temporary LightingLow-Voltage Handlamps: Incandescent Series
Visit Our Website at www.ericson.com
Description Catalog Number12V transformer only - 100va 1931-12Transformer housing only: 1932
includes stainless steel bolts & cord grip bushings
Carrying handle with straps 193312V, 100 watt incandescent bulb, A-21 1935
for use with 1922, 1924 & 1926 Series12V, 30 watt spot bulb 1937
for use with 1928 Series
Replacement Parts
Low Voltage Lighting: Incandescent Series
Low voltage hand lampswith 25’ secondary cord 1922-12A 1924-12A 1926-12Awith 50’ secondary cord 1922-12B 1924-12B 1926-12B
Specifications:Primary Voltage 120V, 60Hz 120V, 60Hz 120V, 60HzSecondary Voltage 12V 12V 12VMaximum Wattage 100 watts 100 watts 100 wattsPrimary cord gauge & type #16/3 SOW #16/3 SOW #16/3 SOWPrimary cord length 10 ft. 10 ft. 10 ft.Secondary cord gauge & type #14/3 SOW #14/3 SOW #14/3 SOWPlug NEMA 5-15 NEMA 5-15 NEMA 5-15
Consult factory for custom assemblies
48
Temporary LightingLow-Voltage Handlamps
Call Toll-Free 1-800-ERICSON (374-2766)
Low-Voltage Handlamps: Spotlight/Floodlight Series
OSHA 1926.405(a)(2)(ii)(G):“Portable electric lighting used in wet and/or other conductive locations, as forexample, drums, tanks, and vessels, shall be operated at 12 volts or less. However, 120-volt lights may be usedif protected by a ground-fault circuit interrupter.”
• Ericson’s handlamps meet OSHA regulations and create a safer working environment• Step-down transformers reduce 120VAC line voltage to 12VAC• Transformer is hermetically encapsulated in TPE rubber and installed in-line on cord• Thick-walled handlamp housing is molded from impact resistant polypropylene thermoplastic• Sealed beam bulb available in spot or flood and protected by an impact resistant polycarbonate lens• Anti-roll hex shaped lens ring is molded from TPE rubber to absorb shock and protect lamp• Optional ON-OFF switch rated at 125V, 8Amps• Switch guard prevents unintentional turning on/off of light• Silicon rubber boot protects switch and seals out jobsite contaminants• Also available in a 12VDC version, SL and FL Series, with cigarette plug• High-visibility dual-color safety system for easy identification on the jobsite
Ericson High-Intensity Hand Lamps are portable, and have wide application in virtually every industrydemanding safe, reliable, and intense illumination. They are ideal for inspecting tanks and boilers: and forservice and repair work indoors , outdoors, underground, and in wet or damp locations.
Their high, intense, penetrating, beam allows the user to remain out of the hazardous area while inspectingfrom a safe distance.
Inspecting liquid filled vessels, and at dockside for illuminating underwater installations are other practicaluses for these lamps.
E95676
49
Temporary LightingLow-Voltage Handlamps
Visit Our Website at www.ericson.com
6-Volt, 30 Watts 12 Volt, 30 Watts 12 Volt DC, 30 Watts
w/out switch w/ switch w/out switch w/ switch w/ switch, 25’cord w/ switch, 50’cord
Spotlights 1915-6 1915-6S 1917-12 1917-12S SL12VDC-25 SL12VDC-50
Floodlights 1916-6 1916-6S 1918-12 1918-12S FL12VDC-25 FL12VDC-50
Specifications:
Primary Voltage 120VAC, 60Hz 120VAC, 60Hz 120VAC, 60Hz 120VAC, 60Hz 12VDC 12VDC
Secondary Voltage 12VAC 12VAC 12VAC 12VAC N/A N/A
Maximum Wattage 30 watts 30 watts 30 watts 30 watts 30 watts 30 watts
Primary cord gauge & type #16/3 SOW #16/3 SOW #16/3 SOW #16/3 SOW #18 SJTW #18 SJTW
Primary cord length 4 ft. 4 ft. 4 ft. 4 ft. 25 ft. 50 ft.
Secondary cord gauge & type #16/2 SOW #16/2 SOW #16/2 SOW #16/2 SOW N/A N/A
Secondary cord length 50 ft. 50 ft. 50 ft. 50 ft. N/A N/A
Plug NEMA 5-15 NEMA 5-15 NEMA 5-15 NEMA 5-15 12VDC cigarette plug 12VDC cigarette plug
Beam Spread
Bulb Specifications Bulb Type Candlepower Horizontal Vertical
1915 Series 4515 Spot 55000 6 4
1916 Series 4511 Flood 4000 Trapezoidal
1917 Series 4416 Spot 35000 9 5
1918 Series 4406 Flood 800 80 30
SL12 Series 4416 Spot 35000 9 5
FL12 Series 4406 Flood 800 80 30
Consult factory for custom assemblies
Low Voltage Lighting: Spotlight/Floodlight Series Selection Guide
1915 Series
1.81
1.5
9.06
Ø5.77
50
Temporary LightingLow Voltage Transformers
Call Toll-Free 1-800-ERICSON (374-2766)
• Transformers convert 120VAC/60Hz line voltage to either 12VAC or 6VAC• Corrosion resistant enclosures are rated NEMA 4 and made from nonconductive engineering
resin so they are resistant to impacts, and jobsite chemicals such as acids, alkalines, oils and salts• NEMA 5-15 outlets are rated at 100va each is designed to accommodate a 50 ft. #14/3 SO secondary cord• Outlets operate independently of each other• Circuit breakers wired individually to each receptacle and operate independently
of each other – if one circuit opens the other continues to operate
Description Cat. No.6 volt transformer only for 1940-6 1942-66 volt transformer only for 1941-6 1944-612 volt transformer only for 1940-12 1943-1212 volt transformer only for 1941-12 1945-12
NOTES:1. Contact factory for custom assemblies
Isolation Transformer
115 V GROUNDING INPUT
WEATHERPROOF COVERGROUNDED SHIELD
SECONDARY
2 WIRE OUTPUT (12V)
NEUTRAL OR (WHITE)SYSTEM GROUND
EQUIPMENT GROUND
(GREEN)
HOT (BLACK)
Low Voltage Transformers Selection Guide
Replacement Parts
12 Volt Transformers 6 Volt Transformers
1940-12 1941-12 1940-6 1941-6
Specifications:
Number of Outlets 2 4 2 4
Outlet Configuration (1) NEMA 5-15 NEMA 5-15 NEMA 5-15 NEMA 5-15
Input (primary) voltage 120V/60Hz 120V/60Hz 120V/60Hz 120V/60Hz
Output (secondary) voltage 12V, 200VA 12V,400VA 6V,200VA 6V,400VA
Outlet Rating 10Amp/100va 10Amp/100va 20Amp/100va 20Amp/100va
Cord gauge/type 14/3 SO 14/3 SO 14/3 SO 14/3 SO
Cord length 6 ft. 6 ft. 6 ft. 6 ft.
Plug (1) NEMA 5-15 NEMA 5-15 NEMA 5-15 NEMA 5-15
Enclosure Environmental Rating TYPE 4 TYPE 4 TYPE 4 TYPE 4
Dimensions (in) (LxWxH) 7 x 7 x 6-1/2 11 x 9 x 6-1/2 7 x 7 x 6-1/2 11 x 9 x 6-1/2
Weight (lbs) 13.5 22.5 13.5 22.5
1941-12
Low Voltage TransformersEricson’s Heavy duty isolation-type low voltage transformers feature lowvoltage safety and extreme weather resistance. Designed for demanding
environments, these transformers withstand long periods ofrugged use. Available in either 6 Volt or 12 Volt models with
either 2 or 4 outlets. Each outlet is covered by Ericson’sflip seal cover to provide added protection
against the most extreme environmentssuch as: boiler inspection, work inside
drums, tanks and vessels. In damp,confined locations it is imperative thatline voltage be reduced to eliminate the
hazards of shorts and shock and to meetthe requirements of OSHA
1926.405(a)(2)(ii)(G).
1940-12
51
Temporary LightingExtension LIghts
Visit Our Website at www.ericson.com
Extension Lights for Secondary side of TransformersThese lights come with the appropriate low voltage bulb and plug directly into the 1940/1941 Series transformers.Choose either Ericson’s Vapor-Gard ™ lamp or spotlight. As with other Ericson products, we have incorporated ourdual-color safety system™ on these hand lamps. You receive greater people protection with our startling, brilliantorange and radiant yellow colors that add a new level of safety in usually dull application area.
NOTES:1. Contact factory for custom assemblies
Extension Lights for Use with Low Voltage Transformers
Extension Lights
1948-12 1950-12
Specifications:
Input (primary) voltage 12 V 12 V
Cord gauge/type #14/3 SO #14/3 SO
Cord length 50 ft. 50 ft.
Plug NEMA 5-15 NEMA 5-15
Included lamp 12 V/100 watt 12 V/30 watt
52
Temporary LightingHazardous Duty Incandescent & Fluorescent Handlamps
Call Toll-Free 1-800-ERICSON (374-2766)
CERTIFIED
Listed 1L72Portable Lighting Unit For Hazardous Locations
Available Options:• Prewired with up to 200 ft. of listed #16 or #14, 3-conductor flexible cord, types: S, SO, ST, STO• Also available with your choice of plug• Contact factory for custom assemblies
2300 Series Incandescent 2400 & 2500 Series Fluorescent
Hazardous Duty Incandescent and Fluorescent Handlamps• UL Listed and CSA Certified• Lightweight construction features non-sparking aluminum guard and non-conductive, high-impact glass reinforced handle
• Designed for applications requiring weather resistant or spark resistant construction• Unique cord restraint seal system includes flex relief and cable cord clamp to provide superior water resistance at cord entry
• Cable cord clamp can be inspected or adjusted without disassembly of handle• Accommodates #14/3 types S, SO, ST or STO cord• High-impact tempered glass globe threads directly into specially designed handle• Handle construction provide superior strength and high insulation properties• Resistant to heat up to 300° F and withstands chemicals, acids and chipping• Heavy-duty aluminum guard features 360° swivel hook• Incandescent handlamp accommodates up to 100 watt bulb• Fluorescent handlamps available in 13 watt and 26 watt models
53
Temporary LightingHazardous Duty Incandescent & Fluorescent Handlamps
Visit Our Website at www.ericson.com
Replacement Parts
2300 Series 2400/2500 Series
2300 Series 2400 Series 2500 SeriesIncandescent Fluorescent Fluorescent
Guard & globe assembly 2301 2401 2501
Handle assembly with socket 2302
Handle assembly with socket, 13 watt 2403
Handle assembly with socket, 26 watt 2503
Lamp, 13 Watt compact fluorescent 2402
Lamp, 26 watt compact fluorescent 2502
NOTES:1. Plug is not explosion proof and is intended to be used outside of the hazardous area2. Contact factory for custom assemblies3. See page 47 for low-voltage hazardous duty lighting
Hazardous Duty Handlamps Selection Guide
20 3/4”
WEIGHT 4.8 LBS.WEIGHT 4.9 LBS.
51/4”2” 2”
33/4”
171/2”
2300 Series 2400 Series 2500 Series
Handlamp Only 2300 2400 2500
Handlamp with 25’cord 2325 2425 2525
Handlamp with 50’cord 2350 2450 2550
Specifications:
EnvironmentsClass I, Divs 1 & 2, Group C, D
Class I, Divs 1 & 2, Group C, D Class I, Divs 1 & 2, Group C, D
Class II, Divs 1 & 2, Group F, G Class II, Divs 1 & 2, Group F, G
Electrical 120V/60Hz 120V/60Hz 120V/60Hz
Maximum Wattage 100 watts 13 watts 26 watts
Cord gauge & type #14/3 SOW #16/3 SOW #16/3 SOW
Plug (1) NEMA 5-15 NEMA 5-15 NEMA 5-15
Guard Anodized Aluminum Anodized Aluminum Anodized Aluminum
Globe Tempered Glass Tempered Glass Tempered Glass
Handle Glass reinforced phenolic Glass reinforced phenolic Glass reinforced phenolic
NEW!
Call Toll-Free 1-800-ERICSON (374-2766)
54
Temporary LightingHazardous Duty Spotlight
Class I, Division I Groups C & D, Class II Division 1, Groups F & G
• UL Listed and CSA Certified• Lightweight construction features non-sparking aluminum guard and non-conductive, high-impact glass reinforced handle
• Designed for applications requiring weather resistant or spark resistant construction• Unique cord restraint seal system includes flex relief and cable cord clamp to provide superior water resistance at cord entry
• Cable cord clamp can be inspected or adjusted without disassembly of handle• Accommodates #14/3 types S, SO, ST or STO cord• High-impact tempered glass globe threads directly into specially designed handle• Handle construction provide superior strength and high insulation properties• Resistant to heat up to 300° F and withstands chemicals, acids and chipping• Heavy-duty aluminum guard features 360° swivel hook
CERTIFIED
Listed 1L72Portable Lighting Unit For Hazardous Locations
2200 Series
Visit Our Website at www.ericson.com
55
Temporary LightingHazardous Duty Spotlight
2200 SeriesSpotlight
Handlamp Only 2200w/ 25 ft. cord 2225w/ 50 ft. cord 2250
Specifications:Environments Class I, Divs 1 & 2, Group DPrimary Voltage 12 VSecondary Voltage n/aTransformer n/aMaximum Wattage 100 wattsPrimary cord gauge & type #14/3 SOWPrimary cord length see aboveSecondary cord gauge & type N/ASecondary cord length N/APlug (1) NEMA 5-15Guard Anodized AluminumGlobe Tempered GlassHandle Glass reinforced phenolic
NOTES:1. Plug is not explosion proof and is intended to be used outside of the hazardous area.2. Contact factory for custom assemblies
Low Voltage Hazardous Duty Handlamps Selection Guide
2200 Series
15.62
Ø5.44 Ø1.63
56
Call Toll-Free 1-800-ERICSON (374-2766)
Temporary LightingEmergency Response Lighting Kit
Here is Ericson’s answer to the most urgent need for safe, low-voltage lighting for practically any type of emergency situation.
At a moments notice, you have your own customized collection of low-voltage hazardous duty lighting devices ready to go. The oversized, extra-heavy reinforced vinyl bag is designed to carry a large load and to store it securely for its next use.
We offer a suggested Standard Emergency Lighting Kit that will meet many needs. Our extensive line of safetylighting equipment makes it easy for you to customize a Kit to suit your particular needs.
Meet OSHA RequirementsMeet NEC Requirements
All recommended low-voltage hazardous duty safety electrical devices meet or exceed OSHA and NationalElectrical Code Requirements. They are intended for use in confined entry applications, chemical wasted clean-ups,accidental spills, and just about any other type of emergency or condition.
High visibility for added safetyAs with all other major Ericson products, we have also incorporated our High-Visibility Dual-Color Safety System TM
on the Emergency Lighting Response Kit itself. At no extra cost, you receive greater people protection with our startling Brilliant Orange and Radiant Yellow colors that can add a new level of safety in hazardous areas involved inemergency situations.
Visit Our Website at www.ericson.com
57
Temporary LightingEmergency Response Lighting Kit
Suggested Emergency Response Lighting Kit-
#1924-12A Low-Voltage Vaporproof Handlamp with a 12 volt in-line transformer and a 25 ft.secondary cord. See Catalog page 47 for details.
#2350 Explosionproof Handlampwith a 100 watt, 120 volt bulb and a 50 ft. cord.See Catalog page 53 for details on this lamp.
#1940-12 Weatherproof Low-Voltage Transformer12 volt, with 2 receptacles, 200 va, each receptacle protected with a Flip Seal Cover. See Catalog page 50 for transformer details
#1948-12 Vaporproof Handlampwith 12 volt bulb, and 50 ft. #14/3 SOY cord. See Catalog page 51 for details.
#1917 High Intensity Low-Voltage Handlampwith in-line transformer and #1937-12 spotlight bulb,4 ft. #16/3 SOY primary cord and 50 ft. #16/2 SOY secondary cord. See Catalog page 49 for details.
#1510PW163B Extension Cord Set50 ft. length with Ericson Perma-Tite water, mud, and dust resistant plug and connector NEMA #5-15, 15 amp 125 volt. See Catalog page 79 for cord set details.
#1000 High Pressure Sodium Portable Lamp(70 watt, 110 volt bulb) with 4 ft. #14/3 SO lead cord,and Ericson Perma-Link plug NEMA #5-15. See Catalog pages 42 - 43 for details.
#2450 Explosion Proof Fluorescent Handlamp2400 Handlamp w/50’ of 16/3 type SOW-A cord and 1510P Perma-Link male plug.
Emergency Lighting Hazardous Duty Bag Available
HOW TO ORDERThe safety electrical devices listed here comprise a SuggestedEmergency Response Lighting Kit that will meet many emergencyneeds.We have many others in our extensive line of safety transformers,handlamps, GFCI’s, outlet boxes, fluorescent lighting, cord sets, etc,.and it will be easy for you to customize a selection to suit your partic-ular needs. Our Catalog Index will help you to locate them.
Please contact your Ericson representative or the factory for assistance.
Call Toll-Free 1-800-ERICSON (374-2766)
58
Temporary LightingFlashlights
FlashlightsEricson offers a wide variety of flashlights for use in construction, general maintenance and hazardous environments.Select the one that is best for your application from our selection guide below.
Flashlights Selection Guide
Standard Flashlights Hazardous Duty Flashlights
100FB 110HZ 115HZSpecifications:Battery 2-D cells alkaline 2-D cells alkaline 2-AA cells alkaline
Lamp 2.4V, KPR-102 2.38V, PR-2 2.38V, PR-2Color Yellow/Black Orange/Black OrangeWeight (w/ batteries) 0.9 0.9Rated Lamp Life (Hrs.) 15 15 15Candlepower 25000 7000 5000Environments Waterproof Class I, Groups C&D Class I, Groups C&D
Class II, Group G Class II, Group GClass III Class IIIMSHA 30CFR Part 20 Approved for use as mining
equipmentOther Flood to spot focusing Switch guard prevents Anti-roll design
Anti-roll design accidental lighting Faceted reflector3-way switch: OFF-FLASH-ON Lens ring stand-offsSpare bulb included Heavy duty lanyard
CERTIFIED
NEW!
Visit Our Website at www.ericson.com
59
Temporary LightingFlashlights
CERTIFIED
Hazardous Duty Flashlights Lanterns Headlamps
120LTNHZ 120LTNRBR 190HDLMP
6 Volt lantern battery 6 Volt lantern battery 4-AA cells alkalinewith spring terminals with spring terminals4.75V, PR-13 4.8V KryptonOrange/Black Yellow Orange1.941550000Class I, Groups C&D Waterproof Class I, Div 1 & 2, Groups C&DClass II, Group G Floats beam-upClass IIIMSHA 30CFR Part 20
Switch guard prevents Large reflector Hands-free operationaccidental lighting Battery included Elastic headband
Lamp housing swivels 45
60
String lights
Visit Our Website at www.ericson.com
61
Temporary LightingTemporary Light Strings
Stringlights
Ericson Manufacturing Company engineers and produces a comprehensive range of molded stringlights for temporary
lighting applications. These stringlights help you create a safer workplace and comply with the NEC and OSHA regulations.
These are molded and assembled under factory-controlled conditions to assure they meet our rigid standards of quality.
So whether your putting up a new office building, lighting a tunnel construction project, trying to light a cruise ship or
manufacturing the next generation military vessel, Ericson has the temporary stringlight you need. In the following pages
you will find Ericson’s comprehensive stringlight offering including:
• Construct-O-Lite 2-wire jacketed molded stringlights
• E-LiteTM midrange/economy 3-wire PVC jacketed molded stringlights
• Heavy-Duty Industrial 3-wire rubber jacketed molded stringlights
• Easy to use charts and drawings simplify the selection/specification process making it quick and user friendly
• Technical reference information to assist in your selection
Construct-O-Lite® 2-Wire Light-Duty Molded Stringlights• UL Listed and CSA Certified
• Meets OSHA construction site requirements & NEC requirements
• Designed for applications that require rapid set-up/tear-down and an economy stringlight
• Available with SJTW or STW cord in 50 ft. and 100 ft. lengths
E-LiteTM Midrange/Economy 3-Wire Molded Stringlights• UL Listed and CSA Certified
• Meets OSHA construction site requirements & NEC requirements
• Designed for applications that require rapid set-up/tear-down and a 3-wire stringlight
• Available with non-conductive, snap-open cage guard or wire guard
• Units come standard with Extra-Hard-Usage STW cord in 50 ft. and 100 ft. lengths
Heavy-Duty Industrial 3-wire rubber jacketed molded stringlights• UL Listed and CSA Certified
• Meet OSHA Construction Site Requirements
• Meets NEC requirements for temporary lighting
• Designed for demanding industrial applications
• Units come standard with Extra-Hard-Usage SEOW cord in 50 ft. and 100 ft. lengths
Custom Built StringlightsAs always you can turn to Ericson Manufacturing Company to engineer a solution to your portable lighting application if you
do not find a standard catalog item to fit your need. Contact the factory or your local sales representative to find out more.
NEW!
NEW!
Call Toll-Free 1-800-ERICSON (374-2766)
62
Temporary LightingConstruct-O-Lite
Construct-O-Lite – 2-Wire Light-Duty Code Compliant Molded StringlightsComply with OSHA regulations and the NEC with these molded stringlights. No more open conductors that can be cut into by metal studs posing and extreme safety hazard. Several different models to choose from.
• UL Listed and CSA Certified• Meets OSHA construction site requirements – 1926.405(a)(2)(ii)(E&F)• Meets NEC requirements for temporary lighting – NEC 305 and NEC 525-13(g)• Designed for applications that require rapid set-up/tear-down and an economy stringlight• Full threaded screwshell to ensure proper contact• Easy relamping with non-conductive, snap-open cage guard• Built-in hanger for easy installation with messenger cable or hooks• Available with SJTW or STW cord in 50 ft. and 100 ft. lengths• Standard models supplied with15Amp, 2-wire straight-blade (NEMA 1-15) plug
C
#14/2 AWG14250 14250STW 142100 142100STW
Specifications:Electrical 120V/60Hz 120V/60Hz 120V/60Hz 120V/60HzOverall Length 50 ft. 50 ft. 100 ft. 100 ft.Cable gauge & type 14/2 SJTW 14/2 STW 14/2 SJTW 14/2 STWGuard 04201 snap on lattice 04201 snap on lattice 04201 snap on lattice 04201 snap on latticeNumber of sockets 5 5 10 10Socket spacing 10 ft. centers 10 ft. centers 10 ft. centers 10 ft. centersMax watts per socket 200 200 150 150Primary NEMA 1-15 plug NEMA 1-15 plug NEMA 1-15 plug NEMA 1-15 plugSecondary Blunt Blunt Blunt Blunt
NOTES:1. Add -NP to catalog number for stringlights with no plug2. Contact factory for custom assemblies
Construct-O-Lite Molded Stringlights Selection GuideStandard products come with 5 ft. primary (lead) and 5 ft. secondary (tail)
Re-lamping is easywith the snap-opencage guard.
Visit Our Website at www.ericson.com
63
Temporary LightingConstruct-O-Lite
Construct-O-Lite®
4.00
8.79
4.89
#12/2 AWG12250 12250STW 122100 122100STW
120V/60Hz 120V/60Hz 120V/60Hz 120V/60Hz50 ft. 50 ft. 100 ft. 100 ft.12/2 SJTW 12/2 STW 12/2 SJTW 12/2 STW04201 snap on lattice 04201 snap on lattice 04201 snap on lattice 04201 snap on lattice5 5 10 1010 ft. centers 10 ft. centers 10 ft. centers 10 ft. centers200 200 150 150NEMA 1-15 plug NEMA 1-15 plug NEMA 1-15 plug NEMA 1-15 plugBlunt Blunt Blunt Blunt
64
Temporary Lighting3-Wire Midrange/Economy Molded Stringlights
Call Toll-Free 1-800-ERICSON (374-2766)
E-LiteTM 3-Wire Economy Molded Stringlights• UL Listed and CSA Certified• Meets OSHA construction site requirements – 1926.405(a)(2)(ii)(E&F)• Meets NEC requirements for temporary lighting – NEC 305 and NEC 525-13(g)• Designed for applications that require rapid set-up/tear-down and a 3-wire stringlight• Full threaded screwshell to ensure proper contact• Available with non-conductive, snap-open cage guard or wire guard• Built-in hanger for easy installation with messenger cable or hooks• Units come standard with Extra-Hard-Usage ST cord in 50 ft. and 100 ft. lengths• Stringlights come standard with Ericson’s Perma-Grip™ plugs and connectors.
CE86155
E-LiteTM
with 201 Wire Guard
9.04
Ø4.75
Visit Our Website at www.ericson.com
65
Temporary Lighting3-Wire Midrange/Economy Molded Stringlights
E-LiteTM 3-Wire Economy Molded Stringlights Selection GuideStandard products come with 5 ft. primary (lead) and 5 ft. secondary (tail)
Stringlights with #12/3 STW Cable:#12/3 STW w/ Plastic Lattice Guard #12/3 STW w/ Wire Cage Guard
50 ft. Overall Length 12350STWY-1L 12350STWY-2L 12350STWY-3L 12350STWY-1W 12350STWY-2W 12350STWY-3W
100 ft. Overall Length 123100STWY-1L 123100STWY-2L 123100STWY-3L 123100STWY-1W 123100STWY-2W 123100STWY-3W
Specifications:
Electrical 120V/60Hz 120V/60Hz 120V/60Hz 120V/60Hz 120V/60Hz 120V/60Hz
Overall Length see above see above see above see above see above see above
Cable gauge & type 12/3 STW 12/3 STW 12/3 STW 12/3 STW 12/3 STW 12/3 STW
Guard 04201 snap on lattice 04201 snap on lattice 04201 snap on lattice 201 Wire guard 201 Wire guard 201 Wire guard
Number of sockets:
50 ft. stringlights 5 5 5 5 5 5
100 ft. stringlights 10 10 10 10 10 10
Socket spacing 10 ft. centers 10 ft. centers 10 ft. centers 10 ft. centers 10 ft. centers 10 ft. centers
Max watts per socket:
50 ft. stringlights 200 200 200 200 200 200
100 ft. stringlights 150 150 150 150 150 150
Plug 1510-PW (NEMA 5-15) 1520-PW (NEMA L5-15) 2310-PW (NEMA L5-20) 1510-PW (NEMA 5-15) 1520-PW (NEMA L5-15) 2310-PW (NEMA L5-20)
Connector 1610-CW (NEMA 5-15) 1620-CW (NEMA L5-15) 2410-CW (NEMA L5-20) 1610-CW (NEMA 5-15) 1620-CW (NEMA L5-15) 2410-CW (NEMA L5-20)
#14/3 STW w/ Plastic Lattice Guard #14/3 STW w/ Wire Cage Guard
50 ft. Overall Length 14350STWY-1L 14350STWY-2L 14350STWY-1W 14350STWY-2W
100 ft. Overall Length 143100STWY-1L 143100STWY-2L 143100STWY-1W 143100STWY-2W
Specifications:
Electrical 120V/60Hz 120V/60Hz 120V/60Hz 120V/60Hz
Overall Length see above see above see above see above
Cable gauge & type 14/3 STW 14/3 STW 114/3 STW 14/3 STW
Guard 04201 snap on lattice 04201 snap on lattice 201 Wire guard 201 Wire guard
Number of sockets:
50 ft. stringlights 5 5 5 5
100 ft. stringlights 10 10 10 10
Socket spacing 10 ft. centers 10 ft. centers 10 ft. centers 10 ft. centers
Max watts per socket:
50 ft. stringlights 200 200 200 200
100 ft. stringlights 150 150 150 150
Plug 1510-PW (NEMA 5-15) 1520-PW (NEMA L5-15) 1510-PW (NEMA 5-15) 1520-PW (NEMA L5-15)
Connector 1610-CW (NEMA 5-15) 1620-CW (NEMA L5-15) 1610-CW (NEMA 5-15) 1620-CW (NEMA L5-15)
NOTES:1. Contact factory for custom assemblies
Stringlights with #14/3 STW Cable:
Call Toll-Free 1-800-ERICSON (374-2766)
66
Temporary Lighting3-Wire Heavy Duty Molded Stringlights
3-Wire Heavy Duty Molded Stringlights• UL Listed and CSA Certified• Meets OSHA construction site requirements – 1926.405(a)(2)(ii)(E&F)• Meets NEC requirements for temporary lighting – NEC 305 and NEC 525-13(g)• Designed for demanding industrial applications• Full threaded screwshell to ensure proper contact• Available with non-conductive, rain-guard or wire guard• Built-in hanger for easy installation with messenger cable or hooks• Units come standard with Extra-Hard-Usage SEOW cord in 50 ft. and 100 ft. lengths• Stringlights come standard with Ericson’s Perma-Tite® plugs and connectors
CE86155
Navy Drops
3.605
3.785
1.682
3.605
3.785
1.682
Visit Our Website at www.ericson.com
67
Temporary Lighting3-Wire Heavy Duty Molded Stringlights
Stringlights with #12/3 SEOW Cable: Stringlights with #14/3 SEOW Cable:50 ft. Overall Length 12350Y-1 12350Y-2 12350Y-3 14350Y-1 14350Y-2
100 ft. Overall Length 123100Y-1 123100Y-2 123100Y-3 143100Y-1 143100Y-2
Specifications:
Electrical 120V/60Hz 120V/60Hz 120V/60Hz 120V/60Hz 120V/60Hz
Overall Length see above see above see above see above see above
Cable gauge & type 12/3 SEOW 12/3 SEOW 12/3 SEOW 14/3 SEOW 14/3 SEOW
Guard see note 1 see note 1 see note 1 see note 1 see note 1
Number of sockets:
50 ft. stringlights 5 5 5 5 5
100 ft. stringlights 10 10 10 10 10
Socket spacing 10 ft. centers 10 ft. centers 10 ft. centers 10 ft. centers 10 ft. centers
Max watts per socket:
50 ft. stringlights 200 200 200 200 200
100 ft. stringlights 150 150 150 150 150
Plug 1510-PW (NEMA 5-15) 1520-PW (NEMA L5-15) 2310-PW (NEMA L5-20) 1510-PW (NEMA 5-15) 1520-PW (NEMA L5-15)
Connector 1610-CW (NEMA 5-15) 1620-CW(NEMA L5-15) 2410-PW (NEMA L5-20) 1610-CW (NEMA 5-15) 1620-CW (NEMA L5-15)
Heavy-Duty Industrial 3-Wire Molded Stringlights Selection GuideStandard products come with 5 ft. primary (lead) and 5 ft. secondary (tail)
NOTES:1. Order guards with 1-3/4” collar separately2. Left-Hand Threaded Sockets - Add ”-L” to catalog number: 123100Y-1 becomes 123100Y-1-L3. Contact factory for custom assemblies
68
Temporary LightingLamp Guards for Stringlights
Call Toll-Free 1-800-ERICSON (374-2766)
Lamp Guards for Stringlights• Heavy-Duty Rain-Guard• Meets OSHA requirements for temporary lighting: Temporary lights shall be equipped with guards to prevent
accidental contact with bulb• One-piece molded high-impact polycarbonate• Prevents accidental contact with bulb• Transparent to let light shine through while protecting bulb from jobsite debris and moisture• Built-in vents dissipate heat and allow air-flow around bulb for cooling• Matching polycarbonate end-cap available to provide complete bulb protection
Patented: Pat. No. 4180851
Heavy-Duty Wire Lamp Guards• Heavy-duty plating provides maximum corrosion resistance• Constructed of heavy-gauge steel• Available with Vinyl coating
Universal style plated or vinyl coated
Collar Diameter
Description 1-11/2” 1-3/4”*
Guard Only #212 #214
Guard with end cap #213 #215
End cap only #216 #216
Length 6- 5/8”. Diameter 411/16”.
*When ordering Lamp Guards for Ericson moldedstringlights, select guards with 1-3/4” diameter guard
holder grooves.Accommodates up to 100 watt rough service lamps.
Heavy Duty Wire Lamp Guards Selection Guide
Guard Style #201 & #211 #219 & #220 #222 #223 & #224Lamp Size up to 150 watt 150 watt PS25 150 watt PAR-38
A-23-RS or 200 watt or 200 watt A-23/RS or 200 watt orA-23/Std. PS30-RS A-23/Std. R-4
Collar Diameter* 1-1/2” 1-3/4”* 1-1/2” 1-3/4”* 1-1/2” 1-3/4”* 1-1/2” 1-3/4”*
Plated #201 #211 #219 #220 - #222 #223 #224
Vinyl coated #201-P #211-P #219-P #220-P - #222-P #223-P #224-P
Dimensions Length 7” Length 10” Length 6-1/2” Length 7-1/2”Diameter 4-3/4” Diameter 5” Diameter 4” Diameter 6-1/2”
Visit Our Website at www.ericson.com
69
Temporary LightingCustom Assemblies Service
Custom Assembly ServiceFor your convenience, we offer the most common stringlights with 10 ft. socket spacing in 50 and 100 ft. lengths.Unlike others however, we go beyond the normal service and offer you a full customized capability toprovide you with the most functional stringlight assemblies that are designed to satisfy virtually any need.
We can install T-Drops on the stringlight assemblies to accommodated a wide variety of devices such as ourPerma-Tite water and dust resistant connectors, outlet boxes, hand lamps (such as our Vapor-Gard vaporproofstyle) and many other devices that you might require. In addition, you can specify desired cord length, cord size,drop length and socket spacing.
Every custom assembly is completely tested and carries the same guarantees as our standard lighting systems.
• To receive a quote on your custom stringlight assembly, simply fill in the blanks on the following page & contact your local Ericson representative or the factory.
70
Temporary LightingStringlight Assembly Configuration
Call Toll-Free 1-800-ERICSON (374-2766)
Stringlight Assembly Configurator
Overall Length: ____________________________________
Primary (Lead) Length: ______________________________
Secondary (Tail) Length: ______________________________
Plug (ex: 1510-PW): __________________________________
Connector (ex: 1610-CW): ____________________________
Cable Size/Type (ex: #12/5 SEO): ______________________
Total Number of Sockets: ____________________________
Spacing between Sockets: ____________________________
Lamp Guard Type (select from list below):201 214 219 222 223211 220 222-P 224201-P 219-P 223-P211-P 220-P 224-P
Are T-Drops Required? ______Yes ______NoHow Many_____________
If Yes: Length of T-Drop: ____________________________________________Cable Size/Type: ____________________________________________Device Required at End (ex: 1610-CW): __________________________Other: ____________________________________________________
Other:______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________The drawing below is intended to serve as a reference tool to assist in the specification of your custom assembly.
Primary (lead)
Plug
Overall Length
LengthSecondary (tail)
LengthSocket Spacing Connector
Cable Size/Type
T-DropDevice
T-Drop
T-DropLength
Visit Our Website at www.ericson.com
71
Temporary LightingNotes
72
Temporary LightingCode Related Issues
Call Toll-Free 1-800-ERICSON (374-2766)
OSHA 1926.405 Safety & Health RegulationsWiring methods, components, and equipment for general use.SubPart Number: K - Electrical - Installation Safety Requirements
(a)(2)(ii)(G) Portable electric lighting used in wet and/or other conductive locations, as for example, drums, tanks, and vessels, shall beoperated at 12 volts or less. However, 120-volt lights may be used if protected by a ground-fault circuit interrupter.
(a)(2)(ii)(E) All lamps for general illumination shall be protected from accidental contact or breakage. Metal-case sockets shall begrounded.
(a)(2)(ii)(F) Temporary lights shall not be suspended by their electric cords unless cords and lights are designed for this means ofsuspension.
(a)(2)(ii)(J) Extension cord sets used with portable electric tools and appliances shall be of three-wire type and shall be designedfor hard or extra-hard usage. Flexible cords used with temporary and portable lights shall be designed for hard orextra-hard usage.NOTE: The National Electrical Code, ANSI/NFPA 70, in Article 400, Table 400-4, lists various types of flexible cords, someof which are noted as being designed for hard or extra-hard usage. Examples of these types of flexible cords includehard service cord (types S, ST, SO, STO) and junior hard service cord (types SJ, SJO, SJT, SJTO).
(j)(1)(iii) Portable lamps. Portable lamps shall be wired with flexible cord and an attachment plug of the polarized or ground-ing type. If the portable lamp uses an Edison-based lampholder, the grounded conductor shall be identified andattached to the screw shell and the identified blade of the attachment plug. In addition, portable handlamps shallcomply with the following:
j)(1)(iii)(A) Metal shell, paperlined lampholders shall not be used;
(j)(1)(iii)(B) Handlamps shall be equipped with a handle of molded composition or other insulating material;
Code Related Issues1999 National Electrical Code
Article 525 – Carnivals, Circuses,Fairs, and Similar Events
Section 525-13(g) - Wiring Methods.Inside Tents and Concessions
This change requires “Electrical wiring for temporary light-ing installed inside of tents and concessions areas to besecurely installed, and where subject to physical damage,the wiring shall be provided with mechanical protection.In addition, all lamps for general illumination shall be protected from accidental breakage by a suitable fixture or lampholder with guard”(See figure 1).
Figure 1
Visit Our Website at www.ericson.com
73
Temporary LightingCode Related Issues
(j)(1)(iii)(C) Handlamps shall be equipped with a substantial guard attached to the lampholder or handle;
(j)(1)(iii)(D) Metallic guards shall be grounded by the means of an equipment grounding conductor run within the power supplycord.
(j)(1)(iv) Lampholders. Lampholders of the screw-shell type shall be installed for use as lampholders only. Lampholdersinstalled in wet or damp locations shall be of the weatherproof type...1926.405(j)(1)(v)
(j)(1)(v) Fixtures. Fixtures installed in wet or damp locations shall be identified for the purpose and shall be installed so thatwater cannot enter or accumulate in wireways, lampholders, or other electrical parts.
OSHA 1926.403 Safety & Health RegulationsGeneral requirements.SubPart Number: K - Electrical - Installation Safety Requirements
(g) Marking. Electrical equipment shall not be used unless the manufacturer's name, trademark, or other descriptive marking bywhich the organization responsible for the product may be identified is placed on the equipment and unless other markingsare provided giving voltage, current, wattage, or other ratings as necessary.The marking shall be of sufficient durability towithstand the environment involved...1926.403(h)
NEC305-4 General (f)Lamp Protection. All lamps for general illumination shall be protected from accidental contact or breakage by a suitable fixture or lampholder with a guard.Brass shell, paper-lined sockets, or other metal-cased sockets shall not be used unless shell is grounded.
410-42(a) General. Portable lamps shall be wired with flexible cord recognized by Section 400-4 and an attachment plug of thepolarized or grounding type. Where used with Edison-base lampholders, the grounded conductor shall be identified andattached to the screw shell and the identified blade of the attachment plug.
(b) Portable Handlamps. In addition to the provisions of Section 410-42(a), portable handlamps shall comply with the fol-lowing. (1) Metal shell, paper-lined lampholders shall not be used.(2) Handlamps shall be equipped with a handle of molded composition or other insulating material.(3) Handlamps shall be equipped with a substantial guard attached to the lampholder or handle.(4) Metallice guards shall be grounded by the means of an equipment grounding conductor run with circuit conductorswithin the power-supply cord.(5) Portable handlamps shall not be required to be grounded where supplied through an isolating transformer with anungrounded secondary of not over 50 volts.
410-44 Cord Bushings. A bushing or the equivalent shall be provided where flexible cord enters the base or stem of aportable lamp. The bushing shall be of insulating material unless a jacketed type of cord is used.
410-49 Lampholders in Wet or Damp Locations. Lampholders installed in wet or damp locations shall be of the weatherproof type.