Download - Stand Alone Email Alarm Controllers
![Page 1: Stand Alone Email Alarm Controllers](https://reader034.vdocuments.site/reader034/viewer/2022052602/559abb601a28abde4a8b45d5/html5/thumbnails/1.jpg)
ICP DAS USA, [email protected]
1-310-517-9888
www.icpdas-usa.com
The Training will
start at 10am PDT
Making Data Acquisition Easy
![Page 2: Stand Alone Email Alarm Controllers](https://reader034.vdocuments.site/reader034/viewer/2022052602/559abb601a28abde4a8b45d5/html5/thumbnails/2.jpg)
Agenda
Modbus Data Acquisition Technology
Sending Email Alarms based on Inputs
Configuring Email Settings
Sending Email Alarms based on Then/Else
Action Statements
Configuring IF-THEN-ELSE Logic Rules
Making Data Acquisition Easy
![Page 3: Stand Alone Email Alarm Controllers](https://reader034.vdocuments.site/reader034/viewer/2022052602/559abb601a28abde4a8b45d5/html5/thumbnails/3.jpg)
ICP DAS USA
• ICP DAS was established in 1993
• Head Quarters located in Hsinchu,
Taiwan
• ICP DAS USA was launched in
2001
Making Data Acquisition Easy
![Page 4: Stand Alone Email Alarm Controllers](https://reader034.vdocuments.site/reader034/viewer/2022052602/559abb601a28abde4a8b45d5/html5/thumbnails/4.jpg)
Modbus Data Acquisition
Technology
Making Data Acquisition Easy
M-7000 Series Remote Data Acquisition Modules
ET-7000 Series ET-7200 Series
![Page 5: Stand Alone Email Alarm Controllers](https://reader034.vdocuments.site/reader034/viewer/2022052602/559abb601a28abde4a8b45d5/html5/thumbnails/5.jpg)
M-7000 Series Remote DAQ
Modules
Making Data Acquisition Easy
• Communication via ModBus RTU protocol.
• Available in a wide variety of Analog and Digital configurations.
• We provide Free EZ Data Logger software with our M-7000 data
acquisition modules for PC based data logging and control.
• Support operating temperatures from -25℃~+75 ℃(-13~167F)• Can be used with WISE-5800 User-defined I/O & Data Logger
Module for Stand Alone Email Alarm Systems
Applications:
• Building Automation
• Factory Automation
• Machine Automation
• Remote Maintenance
• Remote Diagnosis
• Testing Equipment
![Page 6: Stand Alone Email Alarm Controllers](https://reader034.vdocuments.site/reader034/viewer/2022052602/559abb601a28abde4a8b45d5/html5/thumbnails/6.jpg)
ET-7000 Remote Ethernet I/O
Modules Remote web-based Ethernet I/O modules that feature a built-in web server.
Communicate over Ethernet / Modbus TCP protocol.
No programming or HTML skills needed.
Can be used with WISE-5800-MTCP for Stand Alone Email Alarm Systems.
Making Data Acquisition Easy
![Page 7: Stand Alone Email Alarm Controllers](https://reader034.vdocuments.site/reader034/viewer/2022052602/559abb601a28abde4a8b45d5/html5/thumbnails/7.jpg)
ET-7200 Series
Making Data Acquisition Easy
• Built-in Web Server
• Web HMI
• Support for both Modbus TCP and Modbus UDP
Protocols
• Communication Security
• 2-port Ethernet Switch for Daisy-Chain Topology
• Dual Watchdog
• Wide Operating Temperature Range: -25 ~ +75°C
(-13~167F)• I/O Pair Connection
![Page 8: Stand Alone Email Alarm Controllers](https://reader034.vdocuments.site/reader034/viewer/2022052602/559abb601a28abde4a8b45d5/html5/thumbnails/8.jpg)
Sending Email Alarms based on
Inputs
Making Data Acquisition Easy
WISE-5800
Application: Facility Management
• Communicable over Modbus TCP
• Supports 1 XW I/O Expansion board inside
• Supports up to 16 Modbus based devices
• MiniOS7 Operating System
![Page 9: Stand Alone Email Alarm Controllers](https://reader034.vdocuments.site/reader034/viewer/2022052602/559abb601a28abde4a8b45d5/html5/thumbnails/9.jpg)
WISE-5800-MTCP
User-defined I/O & Data Logger Module for Modbus TCP Devices
Communicates over Ethernet, RS-232 and RS-485
Supports operating temperatures from -25 ~ +75°C (-13~167F)
Making Data Acquisition Easy
• Built-in Web Server for IF-THEN-ELSE rule setting
• Built-in IF-THEN-ELSE rule engine for logic
operation
• Support I/O, Counter, Timer, Email, Recipe
operations
• Modbus TCP/RTU Protocol for SCADA Software
Seamless Integration
• Support XW-Board
• Support Modbus TCP Slave Devices(Up to 7)
• SNTP Time Synchronization Supported
Sending Email Alarms based on
Then/Else Action Statements
![Page 10: Stand Alone Email Alarm Controllers](https://reader034.vdocuments.site/reader034/viewer/2022052602/559abb601a28abde4a8b45d5/html5/thumbnails/10.jpg)
Configuring Email Settings
Making Data Acquisition Easy
![Page 11: Stand Alone Email Alarm Controllers](https://reader034.vdocuments.site/reader034/viewer/2022052602/559abb601a28abde4a8b45d5/html5/thumbnails/11.jpg)
Configuring IF-THEN-ELSE Logic
Rules
Making Data Acquisition Easy
![Page 12: Stand Alone Email Alarm Controllers](https://reader034.vdocuments.site/reader034/viewer/2022052602/559abb601a28abde4a8b45d5/html5/thumbnails/12.jpg)
Why Choose ICP DAS USA?
Benefits of our products
• Customized Products & OEM Capability
• Low lead times, cost effective design solutions, and personalized care
• Competitive price/performance ratio, while offering the latest solutions for current industrial trends.
• We are able to provide hardware and software solutions
• ICP DAS USA provides a great variety of products with modular and universal solutions for your applications and projects.
Making Data Acquisition Easy
![Page 13: Stand Alone Email Alarm Controllers](https://reader034.vdocuments.site/reader034/viewer/2022052602/559abb601a28abde4a8b45d5/html5/thumbnails/13.jpg)
Questions?
• Please ask any questions you may have.
Making Data Acquisition Easy