1Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved.
Spot Vision Screener Sample Results
2Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved.
Understanding the Spot DisplayData Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Printed Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Printed Label Report . . . . . . . . . . . . . . . . . . . . . . . . 5Instant Screening Results Displayed . . . . . 6
Definitive Results SamplesScreening Complete . . . . . . . . . . . . . . . . . . . . . . . . . 7Myopia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Hyperopia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Anisometropia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Astigmatism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Strabismus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Anisocoria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Glossary of Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table of Contents
3Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved.
pupil size indicator
pupillary distance
+/- cylinder convention
OD = Right Eye
OS = Left Eye
• alignment indicator
• degree: vertical or horizontal
• complete refraction
• SE = spherical equivalent
DS = sphere
DC = cylinder
Axis = axis
Data Display
4Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved.
• Hyperopia (OD) [ farsighted ]
• Astigmatism (OD) [ problem focusing ]
• Anisometropia [ unequal power]
PediaVision is a registered trademark of PediaVision Holdings, LLC. The Spot logo and information in this report are the trademarks and property of PediaVision Holdings, LLC. Copyright ©2012 by PediaVision Holdings, LLC. All rights reserved.
Vision screening does not replacea complete eye examination by
an ophthalmologist or optometrist.
P O T E N T I A L C O N D I T I O N
L E F T E Y ER I G H T E Y E
Vision screening should be conducted regularly as eyes may change over time.
myopia
hyeropia
astigmatism anis
ocor
ia
anis
omet
ropi
a
gaze
asy
mm
etry
IN RANGE IN RANGEOUT OF RANGE OUT OF RANGE
B O T H E Y E S
Complete Eye ExamRecommended
V i s i o n S c r e e n i n g S u m m a r y
Learn more aboutvision screening at:SpotVisionScreening.com
gaze dev.
SUBJECT ID 21081-13572
SCREENING 01/17/2014 4:27 pm
FIRST NAME Olivia
LAST NAME Dylan
GENDER F AGE 3Y
OD OS
776.0 6.0 mm mm mm
1°➜
➜ 4°1°➜
➜ 0°
+4.00 -2.00 @99°D C
+3.00S E
A x i sD S
+1.75 -0.75 @16°D C
+1.50S E
A x i sD S
- C YLR L
LEVY123456789_20120529_174320_OutOfRange_0_100000.pdf PRINTED ON 05-25-2012 7:53 PM
B
D E
A
K
C
G
J
F
H
C
A
B
D
F
G
H
J
K
E
Disclaimer
Screening Result
Date/Time of Test
Demographic Information
Photo of Subject
Data Display (see page 3 for detail)
Potential Conditions
Right Eye & Le� Eye Results
Analysis of Both Eyes
Customizable Banner
Results (In-Range = blue, Out of Range = red)
( paper )Printed Report
5Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved.
GH
F
C
A
B
D
F
G
H
E
Demographic Information
Cylinder Convention +/-
OD/OS Refractions
Pupil Size Indicator
Pupillary Distance
Alignment Indicator
Potential Condition
Date/Time of Test
A
B
C
D E
( size* )
*Requires Brother QL-720NW label printer as defined in the “Instructions for Use” .
Printed Label Report
6Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved.
“Screening Complete” with the indication of “All Measurements in Range” is consistent with screening results below the configurable threshold setting .
“Complete Eye Exam Recommended” with indication of potential vision disorders is consistent with screening results above the configurable threshold setting .
Instant ScreeningResults Displayed
7Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved.
Screening Complete[ All Measurements in Range ]
8Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved.
Myopia[ Near-sightedness ]
9Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved.
Hyperopia[ Far-sightedness ]
10Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved.
Anisometropia[ Unequal Refractive Power ]
11Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved.
Astigmatism[ Blurred Vision ]
12Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved.
Strabismus[ Eye Misalignment, Gaze ]
13Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved.
Anisocoria[ Pupil Size Deviations ]
14Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved.
Refractive Measurements Consists of Sphere, Cylinder and Axis
Sphere [DS] Measures the power of the eye for myopia and hyperopia
Cylinder [DC] Measures the shape of the cornea
Axis Measurable location of astigmatism
Spherical Equivalent [SE] Equal to the sum of the value of the sphere and half of the cylinder
Pupillary Distance [PD] Distance between the centers of the pupils in each eye
Cylinder Convention There are two different conventions for indicating the amount of cylinder: “plus cylinder notation” and “minus cylinder notation”
OD [oculus dexter] Right eye
OS [oculus sinister] Left eye
Binocular Both eyes
Monocular One eye
Myopia Near-sightedness
Hyperopia Far-sightedness
Anisometropia Unequal refractive power
Astigmatism Blurred vision, eye structure problem
Anisocoria Pupil size deviations
Strabismus Eye misalignment, Gaze
Glossary of Terms
15Vision screening does not replace a complete eye examination by a vision care specialist. This material, trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved.
Vision screening does not replace a complete eye examination by a vision care specialist. This material,
trademarks & property are copyrighted 2014 by PediaVision Holdings, LLC. All rights reserved.
For more information, visit: