Download - SABIANA Product Range UK 2013
www.sabiana.it
Product Range
2013
Sabiana s.p.a. • via Piave, 53 • 20011 Corbetta • Milano • Italyphone +39.02.97203.1 r.a. / +39.02.97270429 / +39.02.97270576 • fax +39.02.9777282 / +39.02.9772820
www.sabiana.it • [email protected]
PROD
UCT
RANG
ENO
VEM
BER
2013
PR -
EX
- 11
/13
Cod.
A401
0100
A/1
1/13
for 80 Yearsa Leading Positionin the Air Conditioning
The descriptions and illustrations provided in this publication
are not binding: Sabiana reserves the right,
whilst maintaining the essential characteristics
of the types described and illustrated, to make, at any time,
without the requirement to promptly update
this piece of literature, any changes that it considers useful
for the purpose of improvement or for any other manufacturing
or commercial requirements.
05 Company
07 History 11 SabianaToday 13 MainProducts
17 RadiantPanels 17 DuckStripRadiantPanels 27 PulsarRadiantPanels 35 DuckVapVacuumSteamHeatingSystem
41 UnitHeaters 43 AtlasUnitHeater 49 AtlasECMUnitHeater 55 HeliosUnitHeater 63 JetstreamInductionFlowOptimizer 67 AIXStainlessSteelUnitHeater 71 AtlasSTPDoorCurtainUnit 75 No-StratAnti-stratificationandHeatEconomiserUnit 79 ComfortCircularUnitHeater 85 PolarisAirConditioner 89 JanusAirConditioner 95 ElegantCeilingAirConditioner
109 FanCoils 111 CarismaFanCoilUnit 113 CarismaCRCFanCoilUnitwithCentrifugalFanwithAsynchronousMotor 121 CarismaCRC-ECM FanCoilUnitwithCentrifugalFanwithECBrushlessElectronicMotorandInverterBoard 129 CarismaCRTFanCoilUnitwithTangentialFanwithAsynchronousMotor 137 CarismaCRT-ECM FanCoilUnitwithTangentialFanwithECBrushlessElectronicMotorandInverterBoard 143 CarismaCRRFanCoilUnitwithTangentialFanwithAsynchronousMotor 147 CarismaCRCMVIversionFanCoilUnitwithCentrifugalFanwithAsynchronousMotor 151 CarismaCRSOHighPressureFanCoilUnitwithAsynchronousMotor 159 CarismaCRS-ECM HighPressureFanCoilUnitwithECBrushlessElectronicMotorandInverterBoard 165 MaestroMTOHighPressureFanCoilUnitwithAsynchronousMotor 171 CrystallFlexSystemElectronicfilter 177 SkyStarSKCassetteFanCoilUnitwithAsynchronousMotor 189 SkyStarSK-ECMCassetteFanCoilUnitwithECBrushlessElectronicMotorandInverterBoard 199 CarismaCoandaOneWayCassetteFanCoilUnitwithAsynchronousMotor 207 CarismaCoanda-ECM OneWayCassetteFanCoilUnitwithECBrushlessElectronicMotorandInverterBoard 213 CarismaFlyHighWallFanCoilUnit 219 CarismaFly-ECM HighWallFanCoilUnitwithECBrushlessElectronicMotorandInverterBoard 225 ControlsforCarisma,SkyStar,MaestroFanCoilUnits 235 AccessoriesforCarismaFanCoilUnits
241 AirHandlingUnits 243 EnergyHeatRecoveryUnit 249 OceanModularDuctedUnit 261 ZeusAirHandlingUnit 269 VulcanProAirHandlingUnit 275 CrystallDuctSystemElectronicfilter 279 VulcanProAirHandlingUnitswithCrystallElectrostaticFilters
287Flues 289 InoxSabiana25StainlessSteelDoubleWallFlues 293 InoxSabiana50StainlessSteelDoubleWallFlues 297 InoxMonoSabianaStainlessSteelSingleWallFlues
301 OtherProducts 301 MeltemiDoorCurtain 305 Electra90/ElectraMaticElectricUnitHeater 309 FSEElectricFanConvector 313 PrimulaMiniconvector
Index
5
CompanyThemainproductlinesare:• Radiantpanels
• Unitheaters
• FanCoils
• Airhandlingunits
• Stainlesssteelflues
• Electricunits
Over 50% of turnover is in foreign markets, especially in Europe,
North and South America and the Middle East, with over 50 exclusive distributors.
In Italy there are 42 Sales Agents who can recommend the Sabiana product
that best fits your climate control needs.
Sabiana is the Italian company that has been designing, producing and
selling innovative heating and air conditioning products for over 80 years.
All of the products use the best existing natural liquid that has always stood
side-by-side with humans in all of their activities: water.In fact, by heating and cooling water, the climate of any work environment
can be controlled with great precision and a high degree of comfort.
Sabiana has paid a great deal of attention to the noiselevel of its products
(it was the first Italian company to introduce radiant ceiling panels in industrial
environments in 1973, providing heating without any noise), their electricalconsumption (it was the first company to introduce Cassette fan coil units
with electronic motors and low power consumption on the Italian market in
2009) and indoor airquality (it was the first company to adopt a patented
electronic filter on a wide range of air conditioners in 1993).
Consistent with the great Italian ability to produce
products with sophisticated design, Sabiana
offers products that can be harmoniously added to any
building's architectural structure.
7
60s production
Since then, over 30.000 systems in all types of environments (small, medium, large industry,
shopping centres, aircraft hangars, sports and recreational centres and zootechnical facilities)
are proof of the product's reliability, with new and highly innovative applications, like the new
plant in Toulouse (France) where the most prestigious European product is built, the new
Airbus A380 that seats 800.
Towards the end ofthe70s,with the first demands for office air conditioning, the heat
convector, designed and sold mainly for domestic use, was gradually replaced by what would
later become one of the most popular air conditioning systems and the most important Sabiana
product: the fan coil. These were the years when Italian design was starting to take hold through-
out the world and it was this period that saw the beginning of the company's collaboration with
one of the leading industrial designers and winner of the Compasso d'Oro (Golden Compass),
Lorenzo Bonfanti. Together we designed the Helios unit heater, which is still a symbol of how a
highly elegant product aimed at heating industrial environments can be built. With the Futura
fan coil, Sabiana, moving away from traditional style patterns, drew the attention not only of
the most important designers, but also of many architects, which have always been strict
regarding any air-conditioning apparatus. The beautiful design along with the traditional
reliability and quietness of Sabiana products, led to the company's success in the ever more
competitive air conditioning market, where large international groups operate.
Office in Via Aprica - the 40s
Sabiana was founded in 1929 by Franco Binaghi and Benvenuto Anatrella.
From Lombardy, passionate about mechanics and a man at home in the
workshop, Binaghi sensed Anatrella's great entrepreneurial and commercial
talents as soon as he moved from Tuscany to the Lombard capital. Starting
with a handshake, like so many other Italian companies, 83 years later the
heirs of the two founders are still passionately involved in this partnership.
The objective remains, as it was then, to produce and sell reliable products
that improve comfort levels in all work environments.
The first electrical unit heater was offered in 1935, and right after the second
world war, production started on hot water unit heaters which, with 7 different
types, still heat and sometimes air condition thousand of establishments
throughout the world today.
At the beginning of the 70s, when the first worldwide energy crisis
occurred, an innovative heating system was proposed for the Alfa Romeo
factory in Arese which used radiant panels installed 12 meters high.
Although not yet in production, Sabiana accepted
the order and delivered the first 10 km of radiant panels
to the customer's great satisfaction, with another 20 km
to follow in subsequent years.
History
9
Sabiana manufacturing plant in Corbetta
Since 1995, every Sabiana fan coil can be installed with an innovative
electrostatic filter named Crystall, patented throughout the world by Luigi
Bontempi, which considerably improves air quality in work environments,
capturing numerous pollutants from the air such as cigarette smoke, dusts,
fibres or microbiological substances such as bacteria or fungi. The filter was
then extended to other products. There were numerous technical meetings
organized by Sabiana dedicated to internal air quality (IAQ) and they are still
receiving a large amount of interest for the prevalence of the problem and
the solutions proposed.
During the 90s there were two other strategic decisions made for the
company's future: the choice to produce flues in stainless steel which soon
allowed Sabiana to become one of the most important companies in the
Italian market and the completion of the range of water-based air conditioning
products with the start of production of a complete series of air handling
units, some in series and some upon specific customer request. They are
very flexible units, with high technical quality, capable of satisfying the ever-
increasing need for environmental comfort.
March2004.Mostra-Convegno Expo Comfort in Milan: Sabiana presents another jewel in their crown: the
SkyStar Cassette fan coil unit, the result of great technical and stylistic research aimed at
offering cutting edge products in terms of performance, quietness and control flexibility.
The intake grille and air diffuser has an absolutely innovative appearance and is capable
of ensuring excellent performance thanks to extensive computer and laboratory tests. It is
the definitive statement in the fan coil industry and places the company at the pinnacle of
European production.
November2012.We start the production of the new Carisma Fly high wall fan coil.
Designed with simple and essential lines, it is entirely manufactured in the Sabiana plants and
it is supplied in several versions including with EC low power consumption motors.
March2011.All Sabiana fan coil units are also offered with inverter electronic motors, the only one capable
of satisfying the class A requirements that were just introduced by Eurovent, the main European
performance certification society.
March2010.Mostra-Convegno Expo Comfort in
Milan: Sabiana presents the new
Carisma fan coil unit with a beautiful
design that gives continuity to the style
proposed with the Futura product as its
noteworthy successor but with a more
current and modern shape. It is
produced in the new factory in Magenta
(MI) that was recently inaugurated and
dedicated to fan coil units, an extremely
modern structure with over 9,000 m2.
Its performance in relation to electrical consumption and noise levels is particularly interesting
as they are among the lowest in the market.
May2009.Sabiana is the first company in the world to introduce Cassette fan coil units on the market
with inverter, permanent magnet, sensorless and brushless synchronous electronic motors.
Electrical consumption decreases by over 50% and continuous adjustment of the air flow rate
improves the precision of the ambient temperature control, at the same time reducing the
average noise level. Market success was immediate and within two years resulted in 10%
of sales having this technology.
History
11
Large manufacturing companies (Airbus), large hotel chains (Sheraton), large banks
(Intesa San Paolo) and large distribution chains (Ikea), to name only a few, which have always
been accustomed to carefully choosing every component in the air conditioning system, show
their approval for the Sabiana brand.
Iso9001 certified since1996 with all products in compliance with European standards and
directives and, where existing, with quality and control certifcations for declared performance,
Sabiana is faithful to the deep-rooted promise of its two founders: we will always be beside
you, those who design or distribute or install our products every day, to help you professionally
and so that you can take priceless satisfaction in having done a good job.
Today Sabiana is an Italian company that directly employsmorethan180people, with three factories near Milan for an overall50.000m2
of surface area andturnover of more than71MillionEuros, over 50%
of which is in foreign markets.
In the last 5 years, on average, 6% of turnover was directed towards
investments in new production technologies and in research and development.
85% of the electrical energy consumed is produced by three photovoltaic
systems for an overall 1.36 Megawatts, perfectly integrated in the architectural
structure of the buildings.
3D design and testing and inspection laboratories,
besides allowing for the creation of reliable products
that are long-lasting, also allows for rapid development
of new products and existing ones, to bring them up to
date with the continuously evolving reference standards,
quality of comfort and the lower energy consumption
required for the buildings.
SabianaToday
13
MainProducts Since 1980 Sabiana has been producingfancoils featuring a beautiful design and very
low noise levels and electrical consumption, in line with the great attention currently towards
energy savings. Every fan coil is available with the latest inverter driven brushless and
sensorless electronic motors.
Performance is certified by an independent institution (Eurovent).
Eight product lines are available with a wide range of accessories and controls, among
which is an electrostatic filter and a control system with wireless technology, both patented,
for comfortable climate control of the most varied work and living environments.
The Sabiana fan coil is one of the reference products in Europe and is constantly growing in
a particularly competitive market.
Since 1973, over30.000installations of Sabianaradiantpanelsin every work and education environment, are proof of the quality of this
system, which allows absolutely silent heating and cooling, with no air
movement, with a uniform temperature throughout the environment, with no
danger of fire and great energy savings. There are two main product lines,
one for industrial environments and the other for the service sector.
Since 1950 Sabiana has been producing hot water and steam unitheaters for heating industrial and commercial environments, with
proprietary production technology and with a wide range of solutions.
Seven product lines, three of which are also suitable for
cooling, allow every designer to find the ideal solution
for any system, taking advantage of the experience
and range of a leading company in Europe.
15
MainProducts Since 1985 Sabiana has been selling single or double wall stainless steel flues for
removing gas from boilers.
There are 8 product lines, 3 ofwhich aremade of plasticmaterial,suitable for the latest generation of condensing boilers.
Since 1990 Sabiana has been producing airhandlingunits with
an air flow of 1.000 to 80.000 m3/h, made to measure according to individual
customer specifications using efficient configuration and selection software.
There are three product lines with single and double panels able to satisfy
air ventilation and climate control needs for practically all environments were
people work and live, with interesting technical solutions capable of reducing
a building's energy consumption (heat recovery units, inverter-driven motors,
electronic filters).
17
Heating
by radiation means
absolute silence,
no forced movement
of the air, uniform
temperatures
throughout the
environment, and no
risk of fire. It means
energy savings,
as people, the walls
and the floor are heated directly, while the air is only heated indirectly, with consequent minimum
stratification of the heat. It means constant operation over time and no routine maintenance
on the product, with the peace of mind that, year after year, at the start of each season, this
product will continue to provide incomparable comfort.
8 different models are available in 2 standard colours and other colours upon request. The
heating emission values have been certified by the leading European certification laboratory,
the University of Stuttgart in Germany. The values have been obtained by applying the
harmonised European standard EN 14037.
Sabiana is the leading European manufactuer in the design, production and
sale ofradiantpanelsoperating on hot water, high temperature hot water
and steam.
Since 1971, over 30.000 installations have been made in all
types of environments (small, medium and large industry, shopping centres,
aircraft hangars, sporting and recreation facilities, zootechnical facilities),
demonstrating the soundness of the product and in new and highly innovative
applications, such as the increasingly widespread air-conditioning of
production areas that guarantees maximum comfort and consistent productivity
all year round, even in the hotter summer months.
Duck
Strip
RadiantPanelsDuckStrip
19
• Steel pipes pressed
into the semicircular sockets on the panel.
StandardVersion: panels fitted with 1.5mm thick pipes,
outside diameter 1/2”, made by electric welding
from high-quality cold rolled steel strips.
The pipes are electronically tested by the manufacturer.
The standard version panels are suitable
for operating pressures up to 4 bars
and maximum hot water temperature up to 120°C.
Upon request, panels
can be supplied for operation between 4 and 10 bars.
SpecialVersion: panels fitted with 2.35mm thick
seamless pipes (or with equivalent features),
outside diameter 1/2”, suitable
for use in systems with operating pressures
up to 16 bars and high temperature hot water temperatures
from 120°C to 180°C.
The pipes have belled ends at one side to ease the longitudinal connection
of the strips with welding. Alternatively, the pipes can be supplied without belled ends
for connections using pressfittings.
Technicalspecifications:• Quality steel radiant panel, 0.8 mm thick,
cold formed by mechanical forming procedure.
The 300, 600, 900 and 1200 mm wide panels
in 6 and 4 m lengths (3 and 5 m upon request),
have semicircular self-locking sockets,
spaced 100 or 150 mm apart depending on the models
that are used to hold the pipes that carry the hot water.
Duck
Strip
RadiantPanelsDuckStrip
21
DescriptionMineral wool insulation treated with heat setting resins,
coated on the outside face with 25 micron aluminium foil.
ReactiontofireClass A1 according to EN 13501-1 standards.
14 kg/m3
1,35 m2K/W
14 kg/m3
0,81 m2K/W
Density
ResistanceM
od. DS3
- Ø
1/2
" pip
es s
pace
d 10
0 m
m a
part
Mod
. DS2
- Ø
1/2
" pip
es s
pace
d 15
0 m
m a
part
Models and Dimensions
Modularwidths
Modularlengths(odd lengths are available on request)
DS3-03
DS2-03
Finalsection
Finalsection
Intermediatesection
Intermediatesection
Firstsection
Firstsection
DS3-06
DS2-06
DS3-09
DS2-09
DS3-12
DS2-12
0,037 W/mK0,037 W/mKThermal conductivityaccording to UNI CTI 7745 and UNI FA 112 standard
50 mm30 mmThickness
Characteristicsof the insulation
TechnicalspecificationsThe totally inorganic nature of the mineral wool ensures
the following characteristics: maintenance of the performance over time,
resistance to parasites and rodents, not hygroscopic, rot-proof.
• Angle brackets for hanging the panel.
• First header and end header,
made by connecting the various pipes in parallel into welded headers,
factory welded and tested to the required operating pressure.
• Sized fibreglass insulation (thickness 30-40-50 mm) protected
at the top by aluminium sheet (*). Other thickness or configurations upon request.
• Side edging strips made from pre-painted plate sections,
to retain the edges of the insulation (*).
• Pre-painted retaining clips (one each metre) to hold the insulation (*).
• Shaped and painted make-up joints,
with fastening bars, to cover the joint areas (*).
• Protection with special phosphate de-greasing procedure
and epoxy polyester coat, dried in a furnace at 180°C.
Colour RAL 9002 (light grey) or RAL 9016 (white). Other RAL colours upon request.
The treatment is not suitable
for the outdoor installation of the radiant panels.
• Reaction to fire class: A1.
• Emission of the radiant surface ε = 0,96.
• The painting complies to the European Standard 76/769/EEC.
(*) with separate packaging.
Duck
Strip
23
4,6
9,2
13,8
18,4
5,6
11,2
16,8
22,4
5,6
11,2
16,8
22,4
7,1
14,2
21,3
28,4
0,63
1,27
1,90
2,54
0,63
1,27
1,90
2,54
1,9
3,7
5,1
6,5
2,1
3,9
5,3
6,7
0,53
1,05
1,58
2,10
0,79
1,58
2,37
3,16
0,43
0,87
1,30
1,74
0,65
1,30
1,95
2,60
STANDARD SPECIAL WATER CONTENT VOLUME ONE HEADER WEIGHT FULL HEADER
kg/m kg/m lt kgStandard
lt/mSpecial
lt/m
Weight and Water content
DS2-03DS2-06DS2-09DS2-12DS3-03DS3-06DS3-09DS3-12
MODELM
odelB
– C
onne
ctio
ns 5
-6M
odelB
– C
onne
ctio
ns 7
-8M
odelD
Mod
elD+D
300
600
900
1200
300
600
900
1200
200
500
800
1100
L
L A
DandD+Dheaders:Distance between the connections mod. 03 = 200 mm mod. 06 = 500 mm
mod. 09 = 800 mm mod. 12 = 1100 mm
D and D+D headers are not suitable for high temperature hot water or steam.
Header “D” should be used with hot water supply
for strips up to 50 m (with slow and gradual opening of the water valve).
For strips longer than 50 m a special “D” header
is recommended, please contact Sabiana Technical Department.
Headers and Connections
03060912
03060912
MODEL
MODEL
Connections
Connections
Connections
Connections
Duck
Strip
25
Table of thermal emission of a couple of headers of the different modelsin accordance to the European Standard EN 14037
293337404448525660646872768085899397
100102106111115120122124129133138142147152156161166171175180185190195200204209214219224229234239244250255260265270275280286291296301307
32353944485256606569747883879297
101106109111116121126131133136141146151156161167172177182188193198204209215220226231237242248254259265271276282288294299305311317323329335340
202224262830323436384042444648505254555658606264656668707274767880828486889092949698
100102104106108110112114116118120122124126128130132134136138140
202224262830323436384042444648505254555658606264656668707274767880828486889092949698
100102104106108110112114116118120122124126128130132134136138140
576471788693
101109117125133141150158167175184193197202211220229238242247256266275284294303313323333342352362372382392402412423433443454464474485495506517527538549560570581592603614625
576471788693
101109116124132140149157165174182191195199208217226235239244253262271280289299308318327337346356365375385395405414424434444454464475485495505516526536547557568578589599610
8696
107118129140152163175187199211224236249261274287294300313327340353360367380394408422436450464478492507521536550565579594609624639654669684699714730745761776792807823839854870886902918
91101113124135147158170182194206218231243256268281294301307320333346360366373386400414427441455469482496510525539553567581596610625639654669683398713728743757772788803818833848863879894909
108121135148162176191205220235250266281297313328344361369377393410427443452460477495512529547564582599617635653671689708726745763782800819838857876895914933952972991
10111030105010691089110911291149
115129144158173189204220236252268285301318335353370387396405423441459477486495514532551570588607627646665685704724743763783803823843864884905925946966987
100810291050107110921114113511561178119912211243
W WW WW WW W(K) (K)
DS2-12 DS3-12DS2-09 DS3-09DS2-06 DS3-06DS2-03 DS3-03∆tm ∆tm
Thermal emission of The headers
∆tm = difference between the mean water temperature and the room temperature.
Table of thermal emission for each meter of the different models of radiant panelsin accordance to the European Standard EN 14037
5157636975818793
100106112119125132139145152159162165172179186193196200207214221228235242249256263271278285292300307314322329336344351359366374381389396404412419427435442450458465473
596673808895
103110118126134141149157165174182190194198207215224232236241249258267275284293302311320329338347356365374383393402411420430439449458468477487496506515525535544554564574583
202224262830323436384042444648505254555658606264656668707274767880828486889092949698
100102104106108110112114116118120122124126128130132134136138140
202224262830323436384042444648505254555658606264656668707274767880828486889092949698
100102104106108110112114116118120122124126128130132134136138140
90100111122133144155166177189200212223235247259271283289295307319331344350356368381394406419432444457470483496509522535548561575588601614628641655668682695709723736750764777791805819833847
105117130142155169182195209223237251265279293308323337345352367382397412420427442458473489504520536552568584600616632648664681697714730747763780797813830847864881898915932950967984
100110191036
126141155171186201217233249265281297314330347364380397406415432449466484493501519537555572590608627645663681700718737755774792811830849868887906925944963983
10021021104110601080109911191138115811781198
152170188207226245265284304324344365385406427448469491501512534556578600611622644667689712735757780803827850873897920944968992
101610401064108811121137116111861210123512601284130913341359138414101435146014861511
170189209229250270291312333355376398420442464486509531543554577600623646657669692716739763787810834858883907931955980
100410291054107811031128115311781203122812531279130413301355138114061432145814831509153515611587
194217241265289313338363388413439465491518544571598625639652680707735763777791820848877905934963992
102110511080111011391169119912291259129013201351138114121443147415051536156715981629166116921724175617881819185118831916
W/m W/mW/m W/mW/m W/mW/m W/m(K) (K)
DS2-12 DS3-12DS2-09 DS3-09DS2-06 DS3-06DS2-03 DS3-03∆tm ∆tm
Thermal emission of The Panels
∆tm = difference between the mean water temperature and the room temperature.
Duck
Strip
27
ThePULSARSabiana ceiling mounted radiant panels are produced in 4
sizes, with a width of 600 mm and a length between 1.2 and 3 m, in 2 standard
colours, and others upon request. The panel has a very elegant design,
perfectly matching the false ceiling (it is also available in a free hanging version
identified by the letter "W"), features simple maintenance, very long life and
can be connected in series or in parallel to others panels using flexible pipes
supplied upon request.
The panels feature a very interesting construction: modern welding units,
without leaving any visible traces, press the pipes into the thick electro-
galvanised steel panel, guaranteeing an optimum heat output and a uniform
temperature across the entire radiating surface. The product is ideal for many
types of environment, especially schools and hospitals.
Pulsar
The panel can be supplied with hot or cold water: in the summer, it should be used together
with a primary air system, as only sensible cooling is provided.
The heating capacity values have been certified by the leading European laboratory in the
sector (University of Stuttgart), applying the European EN 14037 standard.
The painting process, using an epoxypolyester resin powder coat dried in a furnace at 180°C,
ensures high resistance over time, in compliance with the international standard ISO 2409,
certified by tests performed at the Milan Polytechnic University.
PulsarRadiantPanels
29
Technicaldescription:• The radiant panels are supplied in four sizes,
which can be perfectly integrated into any false ceiling.
• Indeed, the lengths of 1.20, 1.80, 2.40 and 3.00 m
ensure optimum integration into 600 x 600 mm modular ceilings,
the standard dimension for false ceiling panels in Europe.
• The visible side is perfectly flat,
meaning that the Pulsar radiant panels can
match all types of false ceiling panels available on the market.
• As standard, the panels are supplied in the colour RAL 9016, with a
satin finish created by an epoxy-polyester coat dried in a furnace at 180°C.
Other RAL colours are also available for the architect to choose from.
• The radiant panels are made of
a radiating galvanized steel plate, 1 mm thick.
Pulsar
On the panel is fixed a galvanized steel pipe
with 15 mm of external diameter, 1.2 mm thick.
The galvanized omega strips welded to the
panels hold the correct spacing of the tubes
and secure the best surface contact between
the tube and the panel.
• The paint complies with the European
Standard 76/769/EEC.
• Fire reaction class: A1.
• Emission of the radiant surface ε = 0,96.
• The radiant panels are supplied with an
insulating layer of mineral wool (30 mm
thick) protected by an aluminium sheet
(25 micron thick) to be mounted on the top
of the panel.
• The insulation is in Class A1 according to
EN 13501-1 standard.
• Thermal conductivity 0,037 W/mK (according to UNI CTI 7745 and UNI FA 112 standard).
• Density 14 kg/m3.
• Thermal resistance 0,81 m2K/W.
Omegastrips
Shapedtube
Panel
TYPICALSECTION
VersionP.FE
Insulation,30mmthick(suppliednotmounted)
Insulationholdingstrip
VersionW.FE
Insulation,30mmthick(suppliednotmounted)
Insulationholdingstrip
PulsarRadiantPanels
31
2429354046525763697581
334048556270788593
101108
40495868778796
106116126136
56688092
105118130143156169182
595
6060
35
1515
565
A
35
1515
565
595
A
6060
56789
101112131415
WITH INSULATION W/ml W/m2
WITHOUT INSULATION W/ml W/m2°C
∆tmCOOLING EMISSION
582574567559552544537529522515507500492485
478470463456448441434427419412405398391383
376369362355348341334327320313306299292285
279272265258251245238231225218211205198192
185179172166160153147141134128122116110104
8988878685848382818079787776
7574737271706968676665646362
6160595857565554535251504948
4746454443424140393837363534
3332313029282726252423222120
W/ml W/ml W/ml W/ml W/ml°C °C °C °C °C
∆tm ∆tm ∆tm ∆tm ∆tmEMISSION EMISSION EMISSION EMISSION EMISSION
Thermal emissions in accordance wiTh
The euroPean sTandard en 14037–1
cooling emissions in accordance wiTh
The euroPean sTandard en 14037–4
∆tm = difference between the average water temperature and the room temperature.
Pulsar
1,3
2,0
2,8
3,5
1,3
2,0
2,8
3,5
1195
1795
2395
2995
1234
1858
2482
3106
13,8
20,7
27,6
34,5
13,8
20,7
27,6
34,5
Dimensions, Weight, Water content
WIDTH WEIGHT WATER CONTENT
LitresA (mm) kg
P.FE 1P.FE 2P.FE 3P.FE 4W.FE 1W.FE 2W.FE 3W.FE 4
MODEL
Models1and2
Models3and4
33
Pulsar
90° flexible pipe
1/2” female fittings.
Straight flexible pipe
1/2” female fittings.
Non-active aesthetic panel "W" type(not installed within false ceilings)
The aesthetic panels are usedwhen the active panels do not need to be installed
and when, for aesthetic reasonsor local specifications, a non-active panel
has to be installed to complete a strip.Can be cut to measure on site.
Non-active aesthetic panel "P" type(installed within false ceilings)
The aesthetic panels are usedwhen the active panels do not need to be installed
and when, for aesthetic reasonsor local specifications, a non-active panel
has to be installed to complete a strip.Can be cut to measure on site.
Pressfittings
(Geberit)
Screw fittings
(Caleffi)
Accessories
90° / Straight flexible pipe
1/2” female fittings.
Accessories
Hanging systems
P.FE
W.FE
35
The main advantages involve
exceptionally uniform temperature
in the environment, fast stabilisation
of the operating conditions, and
a particularly simple and long lasting
system with reduced energy consumption
(almost no power consumption).
TheDuckVap radiant panels are produced in 6 different models,
with 2 standard colours, and others upon request. Each model features elements
measuring 4 and 6 metres in length (3 and 5 metres upon request).
Each element can be easily connected by welding the pipes supplied with belled ends.
The first and last elements are fitted with welded headers
and tested in the factory using advanced automated processes.
The painting process, using an epoxypolyester resin powder coat dried
in a furnace at 180°C, ensures high resistance over time, in compliance with the international
standard ISO 2409, certified by tests performed at the Milan Polytechnic University.
TheDuckVap radiant heating panels have been designed to respond
to the need to ensure optimum comfort from a radiant system in all industrial
environments where a traditional heating plant is not feasible.
One or more steam generators under vacuum, or VAS, installed in a
sheltered location outside, cause the steam to expand inside the suitably
modified pipes of the radiant heating panels, with condensate return by
gravity. The circuit is closed and sealed, there is no consumption of steam
and consequently no need to top up the water.
The vacuum system allows steam to be produced at a maximum temperature
of 110°C corresponding to a relative pressure of 0.45 bar (1.45 bar absolute).
VacuumSteamHeatingSystemDuckVap
Duck
Vap
37
• Control panel
with black bulb probe:
1) Control unit for wall mounting
2) Main on/off switch
3) Button with indicator light
to signal burner shutdown and reset
4) Digital weekly on/off timer
5) Digital electronic thermostat
with two temperature thresholds,
"day" (comfort) and "night" (reduced)
• ASA air venting device:
1) Level sensor
2) Air vent solenoid valve
3) System pressure indicator light
4) Vent in progress indicator light
5) Box for the control equipment
6) Temperature probe
7) 3/4" gas fitting
• VAS series steam generators:
70
105
157,5
63,7
95,5
143,3
0,45
0,45
0,45
110
110
110
590
750
994
245
295
320
RATED FLOW-RATEQn Hi
RATEDOUTPUT
MAXIMUMPRESSURE
MAX. STEAMTEMPERATURE
DIMENSIONS
A C
kW kW bar °C mm mm
VAS 63VAS 95VAS 143
MODEL
Blackbulbprobe
Technicalcharacteristicsofthemaincomponents:• Duck Vap series radiant heating panels:
304
543
766
374
665
966
EMISSION EMISSION
Ambient temperature18°C
Ambient temperature18°C
VAP 203VAP 206VAP 209
VAP 303VAP 306VAP 309
MODEL MODEL
VacuumSteamHeatingSystemDuckVap
Duck
Vap
39
994
820
320
1556
DN100 PN16
DN32 PN16
M 1 ½" G
F 1/4" G
250
F 1 ¼" G
385
180
750
820
295
1556
DN100 PN16
DN25 PN16
M 1" G
F 1/4" G
200
F 1" G
290
140
590
820
245
1556
DN65 PN16
DN25 PN16
M 3/4" G
F 1/4" G
180
F 1/2" G
225
115
Overall dimensions: A mm
B mm
C mm
H mm
Steam outlet: ØM
Condensate return: ØR
Safety valve attachment: ØS
Vacuum valve attachment: ØV
Rated flue diameter: ØF mm
Gas supply attachment
Empty weight kg
Water content lt
MODEL VAS 143VAS 95VAS 63
312
556
785
383
680
991
304
543
766
374
664
966
296
529
747
364
647
942
Troom = 16°C
CARRIER FLUID: STEAM AT 110°C (P = 0,45 bar)
Troom = 18°C Troom = 20°CW/m W/m W/m
VAP 203VAP 206VAP 209VAP 303VAP 306VAP 309
MODEL
VAS series steam generators
Thermal emission of The Panels
Due to the special constructional characteristics,these steam generators can be configured as modules to achieve higher heat outputs.
VAP203
VAP206
VAP209
Mod
. VAP2
Ø 1
/2" p
ipes
spa
ced
150
mm
apa
rt
4 8 12 6 12 18UNIT WEIGHTkg/m
VAP 203 VAP 303VAP 206 VAP 306VAP 209 VAP 309MODEL
VAP303
VAP306
VAP309
Finalsection
Finalsection
Intermediatesection
Intermediatesection
Firstsection
Firstsection
Mod
. VAP3
Ø 1
/2" p
ipes
spa
ced
100
mm
apa
rt
Models and Dimensions
Modularwidths
Modularlengths
Unit weights
Duck
Vap
41
as well as flexible installation
and easy adaptation
to new production plant layouts even
after installation, mean that still today
thousands of designers and businesses
propose and adopt this heating solution.
Following increased demand
for low-cost cooling in summer, anewgenerationofairheatersfitted with coils designed
for usewithcoldwater, has joined
the traditional series of hot water air heaters,
with the result that a complete range of solutions
can now be offered to meet all needs.
All range is compliant with the new
ERP2013Regulation(EU)No.327/2011 which
requires verylowelectricconsumptionratingsin relation to performances provided.
Sabiana is currently the leading Italian
manufacturer of air heaters, and every day
competes with its eternal German rivals,
helping spread Italian know-how
throughout Europe.
Since 1950 Sabiana has been manufacturing hotwater,superheatedwaterandsteamairheaters for heating
industrial and commercial work environments,
with proprietary manufacturing technology and a wide range of solutions.
Both in Germany and Italy, the countries where
the European manufacturing industry is most developed,
above all regarding machinery, the mostcommon heating system
for industrial environments uses hot water air heaters connected
to a central heating system. The excellent ratio of indoor comfort to
system cost, continual improvements in efficiency of hot water production,
using both condensing boilers and heat pumps,
the use of specific solutions such as flow optimisers on the terminal units,
UnitHeaters
43
The coil of Sabiana Atlas unit heaters with steel tubes Ø 22 mm and aluminium fins has
the following advantages compared with the copper-aluminium small diameter tube coils:
the material used for the steel tube, which is very thick (1 mm instead of 0,3 - 0,4 mm), makes
the Sabiana coil extremely sturdy and long lasting. The tube's large diameter reduces the
water pressure drop: this means that reduced power pumps are installed and a very rapid
heating capacity is provided. The Sabiana coil for unit heaters uses a reduced number of
tubes to give the same yield: this determines a low resistance to the air flow and consequently
an optimum leaving air temperature and a very high throw. The greater spacing between the
fins as well as their thickness facilitate cleaning and maintenance operations, which is essential
to keep the unit heater efficient.
The steel tube coil is the ideal choice for plants where all tubes and equipment are made
of steel because it avoids physical and chemical unbalance due to the interaction of different
metals. The special painting coat makes the coil long lasting and increases the thermal
output.
The ATLASSabiana unit heaters have a big ”heart”: a coil, which has
been developed, studied and constructed expressly for heating industrial
environments. The increased thickness of the tubes (1 mm steel tube, 0,7 mm
copper tube), their large diameter (Ø 22 mm) and the excellent ratio between
the air flow and the output guarantee a long life and a high environmental
comfort. The Atlas unit heaters are produced in 10 sizes from 5 to 120 kW
and are available with a 1-row coil for steam and high temperature hot water
installations, a 2-row coil for hot water installations and a 3-row coil for low
temperature hot water installations.
Thickness1 mm
Diameter22 mm
Pitch2,5 mm
Fin0,12 mm
UnitHeaterAtlas
Atals
45
The Sabiana coil can be used with hot water, high temperature hot water
or steam, even with a high working pressure.
As a matter of fact each coil is submitted to two tests at 30 bars.
However Sabiana, in order to meet any design and installation need, can offer
a complete set of unit heaters with copper tubes and aluminium fins.
This coil has the same features (tube diameter, fin pitch, etc.) of the steel
coil but it is built with copper tube 0,7 mm thick, of higher quality and with
a total weight which is double compared with the coils normally used for
unit heaters.
The wide range of products includes 10 different sizes with 1, 2 or 3 rows
each.
UnitHeaterAtlas
Atals
MOTOR4/6 POLE
(1350/1000 r.p.m.)
RANGEATLAS
SIZE
4
ROWS
2
COILSTEEL TUBE
COILCOPPER TUBE
46 A 4 2 SX SP
Reference: 46A42 SX
ATLAS identification code
Technicalcharacteristicsofthemaincomponents:• The main casing is manufactured from galvanized prepainted steel finished in a light grey
colour (RAL 9002) and is assembled from three component parts.
• The coil is manufactured from the highest quality steel or copper tube. The fins are pressed from
aluminium sheet, bonded onto the tubes facilitating the maximum transfer contact available.
• The fan and motor assembly is made up of three components: the fan, the motor and the
safety guard, which also acts as the main support. The standard motor fitted is a hermetically
sealed motor which is maintenance free. The motors are supplied as standard for a three
phase 230/400V 50Hz supply, and they are available, according to the size, with 4/6 or 6/8
pole two speed (protection IP55) and with 4 or 6 pole one speed (protection IP44).
A wide range of air boxes and accessories is available.
On request: special voltages and special air boxes.
Upon request, sizes 1 to 6 are available with theinnovativeelectronicmotorswith extremely low energy consumption, controlled by an inverter board and identified by ECM.
The ECM motors allow to decrease electric consumption compared to traditional asynchronous
motors and they enable to adjust the air flow continuously and control the ambient temperature
with precision, with further
benefits in terms of very low
noise levels.
47throw cover
SIZE
Mounting heights
Atals
472
526
580
634
688
742
793
900
1010
1117
336
390
444
498
552
606
657
764
874
980
465
465
465
488
488
513
560
575
595
640
(595)
(595)
(595)
(618)
(618)
(643)
(740)
(755)
(775)
(820)
375
429
483
537
591
645
696
803
913
1020
220
220
220
220
220
220
210
210
210
210
130
130
130
130
130
130
140
140
140
140
1 ¼"
1 ¼"
1 ¼"
1 ¼"
1 ¼"
1 ¼"
1 ½"
1 ½"
1 ½"
2"
19
22
26
30
33
38
46
55
65
79
22
25
30
34
40
46
55
66
79
95
24
27
33
38
44
51
61
73
88
106
1,3
1,6
1,9
2,3
3,0
3,5
4,3
5,8
7,6
9,6
2,6
3,2
3,8
4,6
6,0
7,0
8,2
11,1
14,5
18,2
3,9
4,8
5,7
6,9
9,0
10,5
12,3
16,6
21,8
27,3
(32)
(35)
(38)
(42)
(47)
(52)
(63)
(71)
(86)
(98)
(35)
(37)
(42)
(46)
(54)
(60)
(72)
(82)
(100)
(114)
(37)
(40)
(45)
(50)
(58)
(65)
(78)
(89)
(109)
(125)
WEIGHT Kg (ATEX) WATER CONTENT Liters
1R 2R 3R1R 2R 3RA B C (C-ATEX) D E F Ø
12345678910
SIZE
Dimensions, Weight, Water content
4
6
4
6
4
6
4
6
4
6
4
6
6
8
6
8
6
8
6
8
2,5÷3,5
2,5÷3
8
5,5
4
3
50
36
3÷4
2,5÷3,5
11
7,5
4,5
3,5
60
45
3÷4
2,5÷3,5
14
10
5
4
70
50
3,5÷4,5
3÷4
16
12
5,5
4,5
80
60
4÷5
3,5÷4,5
20
15
6
5
100
75
4÷5,5
4÷5
25
18
7
6
130
110
4÷5
3,5÷4
24
18
7
6
120
100
4÷5,5
3,5÷4,5
26
20
9
7
160
130
4÷6
3,5÷5
28
21
11
8
200
150
4÷6
4÷5
30
22
12
9
220
160
46A11
46A12
46A13
46A21
46A22
46A23
46A31
46A32
46A33
46A41
46A42
46A43
46A51
46A52
46A53
46A61
46A62
46A63
68A71
68A72
68A73
68A81
68A82
68A83
68A91
68A92
68A93
68A101
68A102
68A103
MODELREF.
1490 / 1055
1400 / 1010
1330 / 960
2315 / 1640
2100 / 1440
2010 / 1380
3400 / 2215
2960 / 1995
2750 / 1850
4230 / 2845
3525 / 2350
3120 / 2080
5600 / 3630
5280 / 3470
4550 / 2990
6920 / 4700
6450 / 4225
5570 / 3720
5800 / 4400
5400 / 4100
5200 / 3800
8500 / 6000
7600 / 5500
7000 / 5000
10600 / 8000
10000 / 7500
9500 / 7000
12500 / 9500
11900 / 8800
11400 / 8450
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
900 / 700
900 / 700
900 / 700
900 / 700
900 / 700
900 / 700
900 / 700
900 / 700
900 / 700
900 / 700
900 / 700
900 / 700
56 / 48
56 / 48
56 / 48
59 / 51
59 / 51
59 / 51
61 / 52
61 / 52
61 / 52
64 / 54
64 / 54
64 / 54
66 / 56
66 / 56
66 / 56
69 / 60
69 / 60
69 / 60
65 / 60
65 / 60
65 / 60
67 / 61
67 / 61
67 / 61
68 / 62
68 / 62
68 / 62
71 / 65
71 / 65
71 / 65
–
11170 / 8500
12940 / 9790
–
15600 / 11880
17700 / 13390
–
23850 / 17940
27700 / 20710
–
30840 / 23290
35260 / 26630
–
40600 / 30910
46310 / 35250
–
51780 / 40390
59380 / 46430
–
44200 / 37100
53500 / 43800
–
62900 / 52200
72700 / 59700
–
81400 / 67600
98800 / 81100
–
97800 / 79200
118600 / 97300
–
38 / 41
44 / 48
–
38 / 41
42 / 46
–
38 / 42
43 / 47
–
40 / 42
45 / 48
–
39 / 43
43 / 48
–
38 / 43
43 / 48
–
41 / 44
48 / 52
–
42 / 45
48 / 52
–
41 / 44
48 / 52
–
42 / 44
47 / 52
HEIGHTmr.p.m. m3/h dB(A) W °C
HEIGHTmax m
THROWm
COVERm2
MOUNTING HEIGHTS:
HORIZONTALDISCHARGE
VERTICALDISCHARGE
MOTORSPEED
LEAVINGAIR
VOLUME
NOISELEVELAT 5 m.
EMISSIONLEAVING
AIRTEMP.
POLES
12345678910
ATLAS Technical
sPecificaTionsWATER TEMPERATURE 85-75°C
Drop 10°C - ∆tm 65°C - Entering air temperature 15°C
49
Atlas ECM Technical
sPecificaTionsWATER TEMPERATURE 85-75°C
Drop 10°C - ∆tm 65°C - Entering air temperature 15°C
56235457,4155
14,327,5
4,0––
67366408,2353
22,531,7
4,5––
78527609,1650
33,035,5
4,5––
89458709,9448
45,538,5
5,02,635
91047101010,83
4662,040,5
5,53,040
101126110011,39
4578,242,0
6,03,040
5601705
10,1557
21,532,5
4,5––
6713855
11,555534
36,7
5,0––
7823103513,04
5249
40,5
5,5––
8918120514,31
5067
43,5
6,03,040
91023139015,56
4892,545,5
6,53,040
101124158016,73
4612247,0
7,03,540
5623101514,56
5731,532,0
6,0––
6736122016,42
5450
36,0
7,0––
7852150018,68
5173
40,0
8,0––
8945170020,14
5010142,0
8,53,550
91047189521,48
4813644,0
9,53,550
101126207522,60
4716644,0
10,04,055
5588102016,02
6130
32,0
6,0––
6692123018,22
5848
36,7
6,5––
7798151520,96
5570
40,0
8,0––
8893180523,41
5398,542,5
9,03,550
9979
212025,81
5113145,0
10,04,055
101059249028,40
4816645,0
11,04,060
5650177525,34
5759
35,0
7,0––
6800233030,17
5310440,0
9,0––
7924274533,36
5115644,0
10,54,065
81044318536,40
4821946,5
12,04,570
91108345538,11
4726547,0
13,05,075
101108345538,11
4726547,0
13,05,075
5653201029,69
5859
36,0
8,0––
6798252034,39
5596
41,0
9,5––
7930304038,65
5214845,0
11,54,580
81053361042,86
5021147,5
13,55,085
91107384544,48
4924648,0
14,55,085
101107384544,48
4924648,0
14,55,085
56235656,1947
14,327,5
4,0––
67366656,8145
22,531,7
4,5––
78528007,5343
33,035,5
5,0––
89459158,1041
45,538,5
5,02,535
9104710608,7439
62,040,5
5,53,040
10112611559,1238
78,242,0
6,03,040
56017358,5549
21,532,5
4,5––
67138909,574634
36,7
5,0––
7823
108010,68
4449
40,5
5,5––
8918
125511,58
4267
43,5
5,73,045
91023145012,47
4092,545,5
7,03,545
101124165013,34
3912247,0
7,53,545
5623
109012,43
4831,532,0
6,5––
6736
131513,86
4650
36,0
7,0––
7852
161015,50
4373
40,0
8,03,550
8945
183016,59
4210142,0
9,03,550
91047204017,54
4013644,0
10,04,055
101126223518,36
3916644,0
10,54,060
5588
115014,35
5230
32,0
6,5––
6692
139016,11
4948
36,7
7,0––
7798
171018,18
4670
40,0
8,53,550
8893
204020,02
4498,542,5
9,64,055
9979
239521,83
4213145,0
11,04,060
101059281523,68
4016645,0
12,54,565
5650
206022,53
4759
35,0
8,0––
6800
270526,17
4310440,0
10,5––
7924
318528,51
4115644,0
12,04,570
81044369530,74
3921946,5
14,05,075
91108401032,00
3826547,0
15,05,080
101108401032,00
3826547,0
15,05,080
5653
237526,86
4859
36,0
9,0––
6798
297530,45
4596
41,0
11,5––
7930
359033,73
4214845,0
13,55,085
81053426036,83
4021147,5
16,05,090
91107453538,05
4024648,0
17,05,590
101107453538,05
4024648,0
17,05,590
56235803,9635
14,327,5
4,0––
67366954,3333
22,531,7
4,5––
78528354,7232
33,035,5
5,0––
89459655,0430
45,538,5
5,52,535
9104711005,3529
62,040,5
6,03,040
10112612605,6728
78,242,0
6,53,540
56017805,6136
21,532,5
5,0––
67139806,293434
36,7
5,5––
7823
11906,883249
40,5
6,0––
8918
13507,293167
43,5
6,53,045
9102315457,7430
92,545,5
7,03,545
10112417908,2629
12247,0
8,04,050
5623
11808,1635
31,531,0
6,5––
6736
14759,103350
35,7
7,5––
7852
17409,823273
39,0
8,53,550
8945
205010,59
3010141,5
10,04,055
91047234011,21
2913644,0
11,04,060
101126262011,76
2816644,0
12,04,560
5588
168011,19
3430
32,0
8,5––
6692
207512,37
3248
36,7
9,5––
7798
246013,39
3170
40,0
11,04,060
8893
287514,34
3098,542,5
12,54,565
9979
321015,04
2913145,0
14,05,070
101059344015,48
2816645,0
14,55,070
5650
257515,62
3359
35,0
10,0––
6800
334017,60
3010440,0
12,6––
7924
404519,14
2915644,0
15,05,080
81044460020,18
2821946,5
17,05,580
91108513021,10
2726547,0
19,06,085
101108513021,10
2726547,0
19,06,085
5653
291018,53
3459
36,0
11,0––
6798
376520,90
3196
41,0
14,0––
7930
458522,77
3014845,0
17,05,590
81053535524,34
2821147,5
20,06,095
91107589525,35
2824648,0
22,06,5100
101107589525,35
2824648,0
22,06,5100
2,5 ÷ 3,5 2,5 ÷ 3,5 2,5 ÷ 3,5
2,5 ÷ 3,5 2,5 ÷ 3,5 2,5 ÷ 3,5
2,5 ÷ 3,5 2,5 ÷ 3,5 2,5 ÷ 3,5
3 ÷ 4,5 3 ÷ 4,5 3 ÷ 4,5
3 ÷ 4,5 3 ÷ 4,5 3 ÷ 4,5
3 ÷ 5 3 ÷ 5 3 ÷ 5
Vr.p.m.m3/hkW°CW
dB(A)mmmm2
Vr.p.m.m3/hkW°CW
dB(A)mmmm2
Vr.p.m.m3/hkW°CW
dB(A)mmmm2
Vr.p.m.m3/hkW°CW
dB(A)mmmm2
Vr.p.m.m3/hkW°CW
dB(A)mmmm2
Vr.p.m.m3/hkW°CW
dB(A)mmmm2
Inverter PowerSpeedAir flowThermal emissionLeaving air temperatureFanSound pressureHorizontal discharge: HeightHorizontal discharge: ThrowVertical discharge: Height max.Vertical discharge: Cover
Inverter PowerSpeedAir flowThermal emissionLeaving air temperatureFanSound pressureHorizontal discharge: HeightHorizontal discharge: ThrowVertical discharge: Height max.Vertical discharge: Cover
Inverter PowerSpeedAir flowThermal emissionLeaving air temperatureFanSound pressureHorizontal discharge: HeightHorizontal discharge: ThrowVertical discharge: Height max.Vertical discharge: Cover
Inverter PowerSpeedAir flowThermal emissionLeaving air temperatureFanSound pressureHorizontal discharge: HeightHorizontal discharge: ThrowVertical discharge: Height max.Vertical discharge: Cover
Inverter PowerSpeedAir flowThermal emissionLeaving air temperatureFanSound pressureHorizontal discharge: HeightHorizontal discharge: ThrowVertical discharge: Height max.Vertical discharge: Cover
Inverter PowerSpeedAir flowThermal emissionLeaving air temperatureFanSound pressureHorizontal discharge: HeightHorizontal discharge: ThrowVertical discharge: Height max.Vertical discharge: Cover
MODEL
MODEL
MODEL
MODEL
MODEL
MODEL
Atlas A–ECM13
Atlas A–ECM23
Atlas A–ECM33
Atlas A–ECM43
Atlas A–ECM53
Atlas A–ECM63
Atlas A–ECM12
Atlas A–ECM22
Atlas A–ECM32
Atlas A–ECM42
Atlas A–ECM52
Atlas A–ECM62
Atlas A–ECM11
Atlas A–ECM21
Atlas A–ECM31
Atlas A–ECM41
Atlas A–ECM51
Atlas A–ECM61
Thickness1 mm
Diameter22 mm
Pitch2,5 mm
Fin0,12 mm
AtalsECM
AtlasECMUnitHeaterwithECBrushlessElectronicMotorandInverterBoard
SabianaATLAS series is available, for the first 6 sizes,
in version with electronic motor and inverter board.
Technicalcharacteristicsofthemaincomponents:ForthetechnicalcharacteristicsofthevariouscomponentsrefertoATLASUnitHeater,excludingtheElectronicmotor: single phase permanent magnet
brushless electronic motor. The inverter board that controls the motor operation
is powered by single-phase and it generates a frequency modulated
wave form power supply. The electric power supply required for
the machine is therefore single-phase with voltage of 200 - 240 V
and frequency of 50 - 60 Hz.
HelicoidalfanThe fan is made with statically and dynamically balanced
plastic or aluminium blades. Its rational high-capacity
profile provides the maximum air volume with the minimum
energy consumption. The fan hub is secured onto the
motor shaft and it is protected by a safety guard.Measurement performed at 5 meter from the source
Room volume of 500 m3 - Reverberation period of 2 s - Directional factor Q=2 (hemisphere sound emission).
51
Internal/external air mixing boxmanually controlled.
Prepainted steel thickness 1 mm.
Fresh air boxwith manually operated damper
(can be motorized by the customer).
Prepainted steel thickness 1 mm.
Fresh air box.
Prepainted steel thickness 1 mm.
Intermediate sectionfor ARC and AMC air boxes.
Prepainted steel thickness 1 mm.
Double intake hoodwith internal/external air mixing,
manually controlled damper.Wall bracket included.
Prepainted steel thickness 1 mm.
Simple intake hood fitted underneath.Wall bracket included.
Prepainted steel thickness 1 mm.
Blast nozzle hight level diffuser.Recommended
for high ceiling installations.
4 way diffuser.To be used
when discharging downflowto create a 4 way discharge pattern.
For low heights of installation.
4 way diffuser.To be used
when discharging downflowto create a 4 way discharge pattern.
For normal heights of installation.
Flanged connections PN16 UNI 2282.
Suspension platefor ceiling installation.
Wall bracket.
AM
AES
AE
AP
AMC
ARC
Accessories Atals
ATP
AW4
AD
AF
AS
AMP
Accessories
53
Fresh air intake grille suitablewith AE - AES - AMC air boxes.
Galvanized steel thickness 1 mm.
Ball protection grid.
Roof-mounted air intake suitablewith AE - AES - AM - AMS air boxes.
Intermediate sectionfor AE - AES - AM - AMS air boxes.
Internal/external air mixing box,manually controlled
(can be motorized by customer).
Prepainted steel thickness 1 mm.
•IP55motorprotection
•SinglespeedflameproofmotorII2GEExdIIBT4-compliantwiththeATEXStandard
•Capacitorforsinglephasemotor(notmounted)
Atals
AG
APP
AT
AC
AMS
Accessories
Wall electronic controlsfor Atlas ECM Unit Heaters sizes 1÷6
ForeachunitmustbeprovidedtheADCconverterforwallcontrols
ADC signal converter for wall controls fitted on the unit
ADC signal converter for wall controls supplied with separate packaging
3 speed control
3 speed control with electronic thermostat and manual summer/winter switch
ADCA-MADC-SMO-3VCR-T
Delta-Star switchfor two speed Delta-Star motors, 4/6 or 6/8 poles.
Manual two-position switchfor two speed Delta-Star motors, 4/6 or 6/8 poles.
BS 2S without thermostat BS 2-ST with thermostat
Multi-function automatic control panelfor two speed Delta-Star motors, 4/6 or 6/8 poles.
BSA-B without timer BSA-A with manual daily timer BSA-D with digital weekly timer
•TwospeedDelta-Starmotors,4/6or6/8poles,threephase,IP55,withklixonthermicprotection
Controls and Special motorsfor Atlas Unit Heaters sizes 1÷10
55
Helios
Thickness1 mm
Diameter22 mm
Pitch2,5 mm
Fin0,12 mm
TheHELIOSSabianaunit heaters, built with the same criteria of sturdiness
and safety that define all Sabiana products, stand out for the splendid design
of the casing, made using anodised aluminium bars and polished die-cast
corners. They have the same big heart as the Atlas unit heaters: a coil that
has been conceived, designed and manufactured specifically for heating
industrial environments. The thickness of the pipes, standard in steel, the
diameter (Ø 22 mm) and the excellent ratio between the flow-rate of air and
the heat output guarantee long life and exceptional comfort.
UnitHeaterHelios
Helios unit heaters are produced in 6sizes from 5to60kW and are available with
a 1-row coil for steam and high temperature hot water installations, a 2-row coil for hot water
installations and a 3-row coil for low temperature hot water installations.
The coil of Sabiana Helios unit heaters with steel tubes Ø 22 mm and aluminium fins has
the followingadvantages compared with the copper-aluminium small diameter tube coils:
the material used for the steel tube, which is very thick (1 mm instead of 0,3 - 0,4 mm),
makes the Sabiana coil extremely sturdy and long lasting. The tube's big diameter reduces
the water pressure drop: this means that reduced power pumps are installed and a very rapid
heating capacity is provided. The Sabiana coil for unit heaters uses a reduced number of
tubes to give the same yield: this determines a low resistance to the air flow and consequently
an optimum leaving air temperature and a very high throw.
The greater spacing between the fins as well as their thickness facilitate cleaning and
maintenance operations, which is essential to keep the unit heater efficient.
The steel tube coil is theidealchoiceforplants where all tubes and equipment
are made of steel because it avoids physical and chemical unbalance due to the interaction
of different metals.
57
MOTOR4/6 POLE
(1350/1000 r.p.m.)
RANGEHELIOS
SIZE
5
ROWS
3
COILSTEEL TUBE
COILCOPPER TUBE
Reference: 46H53 SX
46 H 5 3 SX
SP
Helios
The special painting coat makes the coil long lasting and increases the
thermal output. The Sabiana coil can be used with hot water, high temperature
hot water or steam, even with a high working pressure. As a matter of fact
each coil is submitted to two tests at 30 bars.
However Sabiana, in order to meet any design and installation need, can
offer a complete set of unit heaters with copper tubes and aluminium fins.
This coil has the same features (tube diameter, fin pitch, etc.) of the steel
coil but it is built with copper tube 0,7 mm thick, of higher quality and with
a total weight which is double compared with the coils normally used for
unit heaters.
HeliosUnitHeater
HELIOS identification code
Technicalcharacteristicsofthemaincomponents:• The main casing is manufactured from 4 angular diecast aluminium components and lateral
elements made of extruded, anodized aluminium in a silver colour.
• The coil is manufactured from the highest quality steel or copper tube. The fins are pressed from
aluminium sheet and bonded onto the tubes facilitating the maximum transfer contact available.
• The fan and motor assembly consists of three components: the fan, the motor and the
safety guard, which also acts as the main support. The standard motor is a hermetically
sealed motor which is maintenance free. The motors are supplied as standard for a three
phase 230/400V 50Hz supply, and they are available, according to the size, with 4/6 or 6/8
pole two speed (protection IP55) and with 4 or 6 pole one speed (protection IP44).
Upon request, all sizes are available with theinnovativeelectronicmotors with
extremely low energy consumption, controlled by an inverter board and identified by ECM.
The ECM motors allow to decrease electric consumption compared to traditional asynchronous
motors and they enable to adjust the air flow continuously and control the ambient temperature
with precision, with further
benefits in terms of very low
noise levels.
59
SIZE
throw cover
Mounting heights
Helios
486
540
594
648
702
756
330
384
438
492
546
600
477
477
477
500
500
525
406
460
514
568
622
676
19
22
26
30
33
38
22
25
30
34
40
46
24
27
33
38
44
51
1,3
1,6
1,9
2,3
3,0
3,5
2,6
3,2
3,8
4,6
6,0
7,0
3,9
4,8
5,7
6,9
9,0
10,5
WEIGHT Kg WATER CONTENT Liters
1R 2R 3R1R 2R 3RA B C D
123456
SIZE
Dimensions, Weight, Water content HELIOS Technical
sPecificaTionsWATER TEMPERATURE 85-75°C
Drop 10°C - ∆tm 65°C - Entering air temperature 15°C
4
6
4
6
4
6
4
6
4
6
4
6
2,5÷3,5
2,5÷3
8
5,5
4
3
50
36
3÷4
2,5÷3,5
11
7,5
4,5
3,5
60
45
3÷4
2,5÷3,5
14
10
5
4
70
50
3,5÷4,5
3÷4
16
12
5,5
4,5
80
60
4÷5
3,5÷4,5
20
15
6
5
100
75
4÷5,5
4÷5
25
18
7
6
130
110
46H11
46H12
46H13
46H21
46H22
46H23
46H31
46H32
46H33
46H41
46H42
46H43
46H51
46H52
46H53
46H61
46H62
46H63
MODELREF.
1490 / 1055
1400 / 1010
1330 / 960
2315 / 1640
2100 / 1440
2010 / 1380
3400 / 2215
2960 / 1995
2750 / 1850
4230 / 2845
3525 / 2350
3120 / 2080
5600 / 3630
5280 / 3470
4550 / 2990
6920 / 4700
6450 / 4225
5570 / 3720
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
1350 / 1000
56 / 48
56 / 48
56 / 48
59 / 51
59 / 51
59 / 51
61 / 52
61 / 52
61 / 52
64 / 54
64 / 54
64 / 54
66 / 56
66 / 56
66 / 56
69 / 60
69 / 60
69 / 60
–
11170 / 8500
12940 / 9790
–
15600 / 11880
17700 / 13390
–
23850 / 17940
27700 / 20710
–
30840 / 23290
35260 / 26630
–
40600 / 30910
46310 / 35250
–
51780 / 40390
59380 / 46430
–
38 / 41
44 / 48
–
38 / 41
42 / 46
–
38 / 42
43 / 47
–
40 / 42
45 / 48
–
39 / 43
43 / 48
–
38 / 43
43 / 48
HEIGHTmr.p.m. m3/h dB(A) W °C
HEIGHTmax m
THROWm
COVERm2
MOUNTING HEIGHTS:
HORIZONTALDISCHARGE
VERTICALDISCHARGE
MOTORSPEED
LEAVINGAIR
VOLUME
NOISELEVELAT 5 m.
EMISSIONLEAVING
AIRTEMP.
POLES
123456
61
Ball protection grid.
4 way diffuser.To be used
when discharging downflowto create a 4 way discharge pattern.
For normal heights of installation.
Flanged connections PN16 UNI 2282.
Suspension platefor ceiling installation.
Wall bracket.
Helios
HPP
AD
HF
HS
HMP
Accessories
Delta-Star switchfor two speed Delta-Star motors, 4/6 or 6/8 poles.
•Capacitorforsinglephasemotor(notmounted)
•IP55motorprotection
Manual two-position switchfor two speed Delta-Star motors, 4/6 or 6/8 poles.
BS 2S without thermostat BS 2-ST with thermostat
Multi-function automatic control panelfor two speed Delta-Star motors, 4/6 or 6/8 poles.
BSA-B without timer BSA-A with manual daily timer BSA-D with digital weekly timer
•TwospeedDelta-Starmotors,4/6or6/8poles,threephase,IP55,withklixonthermicprotection
Controls and Special motors
63
INFLUENCE AREA
Temp. underthe ceiling 30°C
MINUTES MINUTES
Time necessary to reachthe room temperature of 18°C
Time necessary to reachthe room temperature of 18°C
Air speed 0.25 m/s Air speed 0.1 m/s18°C
Temperatureunder the ceiling 19-20°C
18°C
INFLUENCE AREA
Technicalcharacteristics:The use of the JETSTREAMinduction flow optimizer
has the following advantages:
a) Energysaving:
– reduced hot air stratification
within the building.
– reduced operating time
of the units with the same
ambient temperature.
Energy saving varies
between a minimum of 5%
and a maximum of 15%,
with maximum amortization in two seasons.
b)Environmentcomfortadvantages:
– increased floor-temperature uniformity
with greater comfort area.
– possibility to install smaller and quieter units,
due to the increase of the throw.
Four versions are available:
• Manual for wall installation (all sizes)
• Manual for ceiling installation (all sizes)
• Motorized for wall installation (sizes 1÷7 only)
• Motorized for ceiling installation (all sizes)
The manually controlled version calls for manual orientation
of the fins and for them to be locked using a special threaded rod.
The motorized version is supplied
with single phase motor that can be controlled by the remote switch.
AirflowproducedbyaunitheaterWITHOUTinductionflowoptimizer
AirflowproducedbyaunitheaterWITHinductionflowoptimizer
Jetstream
The Atlas unit heaters can be supplied with the innovative JETSTREAMinduction flow optimiser, in the manual version or the motorised version for
wall-hung or ceiling installation. The lower outlet temperature of the air from
the units means less stratification of the hot air in the building and less
operating time for the same ambient temperature. In addition, the increased
air throw means greater uniformity of the temperature at floor level, with an
expansion of the comfort zone, and consequently the possibility to install
smaller and more silent appliances.
InductionFlowOptimizerJetstream
65
8
11
14
16
20
25
-
-
-
-
13
16
19
21
26
31
-
-
-
-
5,5
7,5
10
12
15
18
24
26
28
30
9
13
15
15
18
23
29
32
34
37
-
-
-
-
-
-
18
20
21
22
-
-
-
-
-
-
23
25
26
28
4
4,5
5
5,5
6
7
-
-
-
-
4
5
6,5
6,5
7
8
-
-
-
-
3
3,5
4
4,5
5
6
7
9
11
12
3
4
5,5
5,5
6
7
8
10
13
14
-
-
-
-
-
-
6
7
8
9
-
-
-
-
-
-
7
8
9
10
5,5
8
11
12
13
14
-
-
-
-
4
6,5
8
9
10
12
13
15
18
19
-
-
-
-
-
-
11
12
13
14
0123456789
0123456789
SABIANAUNIT HEATER
SIZE
SABIANAUNIT HEATER
SIZE
WITHOUT JETSTREAM
WITHOUT JETSTREAM WITH JETSTREAM
4P
4P 4P6P 6P8P 8P
4P 4P6P 6P 6P8P 8P 8P
WITH JETSTREAM AT 60° WITH JETSTREAM AT 120°
INSTALLATION HEIGHT H (m)
MAXIMUM THROW L (m)
Mounting heightsand Air throwa)Wallinstallationforhorizontaldischarge:
b)Ceilinginstallationforverticaldischarge:
Speed 0.1 m/s
Speed0.1 m/s
Speed0.1 m/s
MAXIMUM THROW L (m)
LOUVRESINCLINATION 90°
LOW
EST
HEI
GH
T 3m
THROW 30° EVERY SIDE
60° 120°
THROW 60° EVERY SIDE
HEI
GH
T H
m
HEI
GH
TH
m
Jetstream
368
422
476
530
584
638
793
900
1010
1117
1,4
1,7
1,8
2,0
2,2
2,4
2,6
3,0
3,4
3,7
Amm
WEIGHTKg
O - 1O - 2O - 3O - 4O - 5O - 6O - 7O - 8O - 9O - 10
V - 1V - 2V - 3V - 4V - 5V - 6V - 7V - 8V - 9V - 10
MODEL
Dimensions and Weight
O(HORIZONTALDISCHARGE)
V(VERTICALDISCHARGE)
Controls
Remote switch
67
MOTOR 4/6 POLE(1350/1000 r.p.m.)
RANGEAIX
SIZE4
ROWS2
46 I 4 2
Technicalcharacteristicsofthemaincomponents:• The main casing is manufactured from AISI 304 stainless steel, 1 mm thick.
• The adjustable louvres are held firm by spring loaded pivots
and they are mounted in horizontal position on the front part of the unit.
The fins are pressed from aluminium sheet, bonded
onto the AISI 304 stainless steel tubes facilitating the maximum transfer contact.
The AIX units are supplied with flanged connections.
• The standard motor is hermetically sealed and is maintenance free.
The motor is 2 speeds, 3 phase, single voltage, 400V 50Hz, protection IP55,
with klixon thermal protection.AIX Sabiana unit heaters are made with stainless steel structures
and coils with stainless steel pipes and flanged fittings, and aluminium fins.
They are available in four sizes, for a total of eight models. These units can
be supplied with hot water, high-temperature hot water and steam.
They are especially suitable for working environments in which these types
of system configurations are required.
AIXStainlessSteelUnitHeater
Reference: 46I42
AIX identification code
AIX
69
Delta-Star switchfor two speed Delta-Star motors, 4/6 or 6/8 poles.
Manual two-position switchfor two speed Delta-Star motors, 4/6 or 6/8 poles.
BS 2S without thermostat BS 2-ST with thermostat
Multi-function automatic control panelfor two speed Delta-Star motors, 4/6 or 6/8 poles.
BSA-B without timer BSA-A with manual daily timer BSA-D with digital weekly timer
AIX Technical sPecificaTions
HEATING EMISSION
m
m
r.p.m.
r.p.m.
m3/h
m3/h
m
m
dB(A)
dB(A)
kW
kW
kW
kW
Leaving airtemp. °C
Leaving airtemp. °C
Leaving airtemp. °C
Leaving airtemp. °C
2.5 ÷ 4
2.5 ÷ 4
1350
2300
11
59
14.3
33.3
16.5
36.1
1350
2100
11
59
13
33.2
18.9
41.5
1350
3900
16
64
23.4
32.6
27
35.4
1350
3600
16
64
21.1
32.2
30.2
39.7
1350
6900
25
69
37
30.8
42.7
33.2
1350
6300
25
69
36.5
32
53.3
39.9
900
10200
28
68
68.4
34.7
79
37.8
900
9200
28
68
59.2
33.9
84.1
41.9
1000
1500
7.5
51
11.9
38.3
13.8
42
1000
1400
7.5
51
10.6
37.3
15.4
47.3
1000
2600
12
54
19.8
37.4
22.9
40.9
1000
2400
12
54
17.2
36.1
24.7
45.3
1000
4400
18
60
31
35.7
35.9
39
1000
4100
18
60
29.3
36
43
45.8
700
7600
21
62
60.5
38.4
70
42.1
700
7000
21
62
51.4
36.6
74
46.1
3 ÷ 4.5
3 ÷ 4.5
3 ÷ 5
3 ÷ 5
3.5 ÷ 5.5
3.5 ÷ 5.5
Mounting height
Mounting height
Speed
Speed
Air flow
Air flow
Throw
Throw
Noise level at 5 m
Noise level at 5 m
Steam 3 bars
Water temperature 85/75°C
Steam 6 bars
Water temperature 130/100°C
Entering air temperature +15°C
Entering air temperature +15°C
Entering air temperature +15°C
Entering air temperature +15°C
MODEL
MODEL
68 I 91
68 I 92
46 I 61
46 I 62
46 I 41
46 I 42
46 I 21
46 I 22
Controls
Flange
FLOW
RETURN
526
636
743
1011
393
501
609
877
468
468
468
576
506
616
723
991
330
497
588
832
98
69.5
44.5
89.5
66
66
56
87
65
85
100
110
14
14
18
18
1 ½"
1"
1 ¼"
1 ½"
95
115
140
150
15
25
32
40
26
33
45
82
30
38
51
92
1,7
2,9
5,3
8,2
2,5
4,2
5,9
12
WEIGHT Kg WATER CONTENT Liters
1R 2R1R 2RA B C D E F G ØH ØI ØL ØM ØN
46 I 21-2246 I 41-4246 I 61-6268 I 91-92
MODEL
Dimensions, Weight, Water content AIX
71
Technicalcharacteristicsofthemaincomponents:• The main casing is manufactured from galvanized prepainted steel finished in light grey
colour (RAL 9002), and is assembled from three component parts, which are assembled
using self-tapping screws in order to allow quick maintenance on the coil.
• Fishtail diffuser produced from steel sheet with manually adjustable louvres for individual
requirements.
• Coil manufactured from high quality steel or copper tube 22 mm of diameter to reduce
resistance with mechanically bonded aluminium fins for high efficient heat transfer.
Available in 1, 2 or 3 rows.
• Consists of aluminium helicoidal blades statically and dynamically balanced with a cast
alloy hub, keyed into the motor shaft and mounted onto the casing with antivibration rubber
mounting blocks. The motor is supplied as standard for a three phase, 400V 50Hz, class B,
IP55, 6/8 poles two speed: 900 r.p.m. (6 poles) or 700 r.p.m. (8 poles).
The AtlasSTP door curtain units, supplied with hot water, are fitted with
special diffusers that create a curtain of hot air. Installed above the door,
they deliver a constant vertical flow of air, representing a barrier that, by
thermodynamic effect, stops the infiltration of air from the outside, and mixes
the residual cold currents. Available in three sizes, with two speed and 1, 2,
3 row coils.
AtlasSTPDoorCurtainUnit
MOTOR6/8 POLE
RANGEATLAS
SIZE7
ROWS1
TYPESTP
COILSTEEL TUBE
COILCOPPER TUBE
68 A 7 1 /STPSX
SP
Reference: 68A71 SX / STP
Identification code
AtlasSTP
73
SIZE
Atlas STP Technical sPecificaTions
ENTERING AIR TEMPERATURE 15°C
7
8
9
SIZE
793
900
1010
696
803
913
793
900
1010
1000
1200
1400
1
2
3
1
2
3
1
2
3
62
70
76
75
86
93
90
104
113
4.3
8.2
12.3
5.8
11.1
16.6
7.6
14.5
21.8
DIMENSIONSROWS WEIGHT WATER
CONTENTA=B
mm
C D E
kg Liters
6
6
6
8
8
8
3.0 ÷ 4.0
3.5 ÷ 4.5
4.5 ÷ 5.5
2.5 ÷ 3.0
3.0 ÷ 3.5
3.5 ÷ 4.5
1.5
2.0
2.5
1.5
1.8
2.0
789789
SIZE MOTORPOLE
DOOR HEIGHTH (m)
DOOR WIDTHL (m)
Correct selection of the door curtain
Dimensions, Weight, Water content
Sogliainterna
AtlasSTP
r.p.m. kW kW kWLEAVING AIR
TEMP. °CLEAVING AIR
TEMP. °CLEAVING AIR
TEMP. °Cm3/h
MODELREF.
EMISSION
WATER TEMPERATURE85-70°C
WATER TEMPERATURE140-100°C
STEAM0,5 bars
LEAVINGAIR
VOLUME
MOTORSPEED
7
8
9
68A71/STP
68A72/STP
68A73/STP
68A81/STP
68A82/STP
68A83/STP
68A91/STP
68A92/STP
68A93/STP
900 / 700
900 / 700
900 / 700
900 / 700
900 / 700
900 / 700
900 / 700
900 / 700
900 / 700
–
38,4 / 32,5
46,5 / 38,4
–
52,5 / 43,6
60,7 / 50,0
–
70,7 / 58,7
85,7 / 70,4
41,3 / 35,1
60,5 / 50,7
–
57,9 / 49,8
82,6 / 68,6
–
75,6 / 64,3
111,3 / 92,3
–
39,3 / 33,4
–
–
55 / 47,3
–
–
71,8 / 61
–
–
–
43 / 44
52 / 53
–
41 / 44
48 / 53
–
42 / 44
50 / 53
41 / 46
56 / 61
–
40 / 46
55 / 61
–
41 / 46
56 / 61
–
40 / 42
–
–
40 / 42
–
–
41 / 43
–
–
5.000 / 3.700
4.600 / 3.500
4.400 / 3.200
7.300 / 5.100
6.500 / 4.700
6.000 / 4.200
9.000 / 6.800
8.500 / 6.400
8.100 / 6.000
75
Technicalcharacteristicsofthemaincomponents:• The casing is manufactured
from galvanised prepainted steel sheet (1 mm thick)
finished in light grey colour (RAL 9002).
The adjustable louvres are held firm by spring loaded pivots.
• The fan assembly is made up of the aluminium helicoidal fan,
the safety guard support and the three phase V400/3 electric motor
with 4 or 6 poles, protection IP44.
• A room thermostat is mounted on the unit
for the automatic on/off switching of the motor
in accordance with the temperature under the ceiling.
• 3-phase power switch V400/3 with built-in overload protection.
No-StratAnti-stratificationandHeatEconomiserUnit
NO-STRAT, an anti-air-stratification unit, recirculates the hot air down-
wards, hot air that in large spaces heated with warm air (for example, using
hot air generators) tends to stratify towards the top. The temperature controller
fitted on the appliance can be used to set the air temperature at which the
NO-STRAT starts operation. In addition, it can be used to increase the
recirculation air rate and improve the uniformity of the ambient temperature.
The series includes 8 models, with flow-rates from 3.500 to 14.000 m3/h.
No-Strat
77
No-Strat
1) Three phase electric motor
2) Motor support with safety guard
3) Aluminium fan
4) Brackets
5) Ambient thermostat
6) Switch with thermal relay
7) Galvanised and prepainted steel case
8) Adjustable louvres
634
688
742
900
1010
634
688
742
900
1010
629
683
737
895
1005
537
591
645
803
913
488
488
513
575
595
20
23
25
33
42
WEIGHT KgA B C D E
DNS-450/4DNS-500/4DNS-550/4
––
DNS-450/6DNS-500/6DNS-550/6DNS-650/6DNS-750/6
MODEL
Dimensions and Weight
1400
900
1400
900
1400
900
900
900
4.400
3.200
6.500
4.400
6.700
4.750
9.500
13.500
260
100
260
140
370
140
850
850
0,60
0,26
0,60
0,30
0,80
0,30
1,73
1,73
4,5 ÷ 6,5
3,5 ÷ 6
5 ÷ 8
4 ÷ 8
6,5 ÷ 9
5 ÷ 8,5
6,5 ÷ 11
7 ÷ 13
100
60
150
90
200
120
300
400
61
52
66
56
69
60
67
68
MODEL
r.p.m. W 400 V m m2 dB(A)m3/h
MOTORSPEED MOTOR AMPERE INSTALLATION
HEIGHT SURFACENOISELEVELAT 4 m.
LEAVINGAIR VOLUME
DNS-450/4DNS-450/6DNS-500/4DNS-500/6DNS-550/4DNS-550/6DNS-650/6DNS-750/6
NO-STRATTechnical sPecificaTions
79
MOTOR 6 POLE(900 r.p.m.)
RANGE COMFORT SIZE N° OF CIRCUITS
Technicalcharacteristicsofthemaincomponents:• The casing is made of spun steel on both top and bottom
sections which is designed to give greater strength and
quieter operation. The casing is then finished with an epoxy,
polyester powder coating of light grey, RAL 9002.
• The circular coil is constructed of copper tubes with
aluminium fins.
• The helicoidal fan is statically and dynamically balanced, the
rational high-capacity profile provides maximum air volume
with a minimum power consumption.
• Standard motors are three phase 230-400 V, closed frame, flange mounted, pre-greased
bearings, IP 44. Available with single speed at 4 and 6 pole (1400-900 r.p.m.) or with double
speed double wiring at 4/6 or 6/8 pole.
On request: • Flanged connections.
• Steam execution.
6 Z 4 15
COMFORTSabianacircular unit heaters, for ceiling installation only,
are especially suitable for high rooms, even if the optimum ratio between the
air flow-rate and the heat output make them suitable for any manufacturing
environment. The large coil and the fan downstream of the coil ensure optimum
mixing of the air in the environment, meaning less stratification of the hot air
than with traditional unit heaters. Two different diffusers ensure perfect control
of the air flow, with the possibility on the more common diffusers to tilt each
louvre in the desired direction.
The Comfort unit heaters are made in 10 sizes, with heat outputs from 17
to 107 kW, and one or two speeds motors.
ComfortCircularUnitHeater
Reference: 6Z–415
COMFORT identification code
Comfort
81
0123456789
SIZE H suggestedm
H suggestedm
ZONEm ZONEmA AB B
Mounting heightsand
area of air distribution
"T2"two way diffuser
It is designed
to give a two way or corridor distribution,
suitable for corridor or gangway areas,
between storage racks etc.,
generally mounted at any height depending
upon the length of corridor required.
÷
÷
÷
÷
÷
–
–
–
–
–
÷
÷
÷
÷
÷
÷
–
–
–
–
÷
÷
÷
÷
÷
–
–
–
–
–
÷
÷
÷
÷
÷
÷
÷
÷
÷
÷
10x4
10x5
14x5
14x6
15x7
9x4
10x4
10x4
13x5
15x5
16x5
18x6
20x8
22x10
22x10
6
6
7
8
9
5
5
6
6.5
7
8
10
11
15
15
15x6
16x7
18x8
20x10
22x10
13x5
14x6
16x7
17x8
20x10
22x10
24x10
24x11
26x12
26x12
3
3
3.5
3.5
4
2.5
2.5
3
3
3.5
4
4
4
6
6
1400 r.p.m. MOTOR SPEED 900 r.p.m. MOTOR SPEED
Comfort
0123456789
SIZE 45° LOUVRES
H suggestedm
H suggestedm
H suggestedm
H suggestedm
S diameterm
S diameterm
S diameterm
S diameterm
45° LOUVRESVERTICAL LOUVRES VERTICAL LOUVRES
"DRA"radial diffuser
with45°LOUVRES
withVERTICALLOUVRES
Mounting heightsand
area of air distribution
This is the most commonly used model; made of eight
separately adjustable large louvres, shaped
so as to be able to cover the whole outlet area and
therefore adaptable for minimum to maximum heights.
This diffuser allows the air to be directed more easily
to the areas where it is required most, or conversely,
if you do not require air to one particular corner
you can close down one, two or three vanes
and restrict the distribution.
÷
÷
÷
÷
÷
–
–
–
–
–
5
5.5
6
6.5
7
3
3.5
4
4
4
÷
÷
÷
÷
÷
–
–
–
–
–
21
21
25.5
27
28.5
15
16.5
18
18
18
÷
÷
÷
÷
÷
–
–
–
–
–
6
6.5
7
8
9
4
4.5
5
5.5
6
÷
÷
÷
÷
÷
–
–
–
–
–
10.5
12
13.5
15
16.5
7.5
9
10.5
10.5
10.5
÷
÷
÷
÷
÷
÷
÷
÷
÷
÷
4
4.5
5
5.5
6
6.5
8
8
11
11
2.5
3
3
3.5
3.5
4
4
4
5
5
÷
÷
÷
÷
÷
÷
÷
÷
÷
÷
16.5
18
19.5
22.5
24
25.5
28.5
28.5
31.5
33
10.5
12
12
15
15
16.5
16.5
16.5
18
18
÷
÷
÷
÷
÷
÷
÷
÷
÷
÷
5
5.5
6.5
7
8
8.5
10
10
14
14
3.5
4
4.5
5
5.5
5.5
6
6
6.5
6.5
÷
÷
÷
÷
÷
÷
÷
÷
÷
÷
9
10.5
12
13.5
15
15
18
18
19.5
21
6
7.5
9
9
10.5
10.5
12
12
13.5
13.5
1400 r.p.m. MOTOR SPEED 900 r.p.m. MOTOR SPEED
83
Thermal emission with motor running at 700 r.p.m.:Watt = 0.85 x Watt with motor at 900 r.p.m.Air = 0.70 x air flow with motor at 900 r.p.m.
On request: double speed motor, single tension, double wiring, 1400/900 r.p.m. or 900/700 r.p.m.
COMFORT Technical
sPecificaTionsWATER TEMPERATURE 85-75°C
Drop 10°C - Entering air temperature 15°C
Version with PN 16 flanges
DRA T2
The units with steam coils are supplied with connections for welding; on request they can be supplied with flanges.
680
780
780
880
880
1080
1080
1080
1080
1080
180
180
280
280
380
380
455
555
555
605
430
430
530
530
630
630
705
805
815
865
560
560
660
700
760
870
945
1045
1055
1105
380
380
480
480
580
580
655
755
765
815
560
560
560
660
660
760
760
760
760
760
331
331
431
435
535
539
614
714
714
765
612
702
702
802
802
1005
1005
1005
1005
1005
62
62
62
68
68
80
80
80
80
80
350
421
421
491
491
755
755
755
755
755
350
421
421
491
491
440
440
440
440
440
25
25
25
32
32
40
40
40
40
40
31
36
42
52
58
75
85
95
97
106
1,20
1,30
1,90
2,40
3,20
4,30
5,20
5,90
5,90
6,50
A B C C1 F G O P Q R S Ø DN
0123456789
SIZE
Dimensions, Weight, Water content
1 ¼"
1 ¼"
1 ¼"
1 ½"
1 ½"
2"
2"
2"
2"
2"
WATER CONTENTLiters
WEIGHTKg
Comfort
900
900
900
900
900
900
900
900
900
900
6Z-007
6Z-107
6Z-211
6Z-311
6Z-415
6Z-515
6Z-618
6Z-722
6Z-822
6Z-924
43
42
41
40
41
40
40
42
44
44
19.100
22.100
32.700
38.000
50.200
61.500
77.800
92.000
107.000
115.100
48
52
54
55
56
63
64
65
65
66
2.000
2.400
3.700
4.400
5.700
7.100
9.000
9.900
11.000
12.000
1400
1400
1400
1400
1400
4Z-007
4Z-107
4Z-211
4Z-311
4Z-415
39
39
39
39
39
24.400
28.400
41.800
48.800
64.400
56
60
63
65
66
3.000
3.400
5.100
6.000
7.800
r.p.m. °CWdB(A)m3/h
MOTORSPEED
LEAVINGAIR
TEMPERATUREEMISSION
NOISELEVELAT 5 m.
AIR FLOWMODELREF.
0
0
1
1
2
2
3
3
4
456789
SIZE
85
Technicalcharacteristicsofthemaincomponents:• The casing is made of spun steel on both top and bottom sections
which is designed to give greater strength and quieter operation. The casing is then
finished with an epoxy, polyester powder coating of light grey, RAL 9002.
• The circular coil is constructed of copper tubes with aluminium fins.
• The helicoidal fan is statically and dynamically balanced, the rational high-capacity profile
provides maximum air volume with a minimum power consumption.
• Standard motors are three phase 400 V,
closed frame, flange mounted, pre-greased bearings, protection IP 44.
Available with double speed double wiring at 6/8 pole (900-700 r.p.m.).
On request: • Speed switch.
Polaris
POLARISSabianacircular unit heaters, for ceiling installation only, are
especially suitable for high rooms, even if the optimum ratio between the air
flow-rate and the heat / cool output make them suitable for any manufacturing
environment.
The large coil and the fan downstream of the coil ensure optimum mixing
of the air in the environment, meaning less stratification of the hot air than
with traditional unit heaters.
When supplied with cold water they can also be used in the summer months,
thus allowing cooling at very reasonable costs.
The Polaris unit heaters are made in 9 sizes, all fitted with very silent two
speeds motors, heat outputs from 17 to 107 kW and cooling capacities from
2 to 20 kW.
AirConditionerPolaris
87
SIZE
SIZE
Polaris
"DRA"radial diffuser
Mounting heightsand
area of air distribution
Made of eight separately adjustable large louvres,
shaped so as to be able to cover
the whole outlet area and therefore adaptable
for minimum to maximum heights.
This diffuser allows the air to be directed more easily
to the areas where it is required most, or conversely,
if you do not require air to one particular corner
you can close down one, two or three vanes
and restrict the distribution.
Dimensions, Weight, Water contentwith
45°LOUVRESwith
VERTICALLOUVRES
÷
÷
÷
÷
÷
÷
÷
÷
÷
4
4.5
5.5
6
6.5
8
8
11
11
2.5
3
3.5
3.5
4
4
4
5
5
÷
÷
÷
÷
÷
÷
÷
÷
÷
16.5
18
22.5
24
25.5
28.5
28.5
31.5
33
10.5
12
15
15
16.5
16.5
16.5
18
18
÷
÷
÷
÷
÷
÷
÷
÷
÷
5
5.5
7
8
8.5
10
10
14
14
3.5
4
5
5.5
5.5
6
6
6.5
6.5
÷
÷
÷
÷
÷
÷
÷
÷
÷
9
10.5
13.5
15
15
18
18
19.5
21
6
7.5
9
10.5
10.5
12
12
13.5
13.5
680
780
880
880
1080
1080
1080
1080
1080
180
180
280
380
380
455
555
555
605
430
430
530
630
630
705
805
815
865
560
560
700
760
870
945
1045
1055
1105
560
560
660
660
760
760
760
760
760
1 ¼"
1 ¼"
1 ½"
1 ½"
2"
2"
2"
2"
2"
31
36
52
58
75
85
95
97
106
1,20
1,30
2,40
3,20
4,30
5,20
5,90
5,90
6,50
H suggestedm
H suggestedm
S diameterm
S diameterm
45° LOUVRES VERTICAL LOUVRES
900 r.p.m. MOTOR SPEEDDIMENSIONS WEIGHT WATER
CONTENT
Amm
Bmm
Cmm
C1mm
Gmm Ø LitersKg
013456789
SIZE
POLARIS Technical sPecificaTions
P.007
P.107
P.311
P.415
P.515
P.618
P.722
P.822
P.924
P.007
P.107
P.311
P.415
P.515
P.618
P.722
P.822
P.924
48
52
55
56
63
64
65
65
66
48
52
55
56
63
64
65
65
66
2.000
2.400
4.400
5.700
7.100
9.000
9.900
11.000
12.000
2.000
2.400
4.400
5.700
7.100
9.000
9.900
11.000
12.000
3.100
4.000
7.500
10.900
13.600
17.200
18.900
22.000
23.700
17.600
20.400
35.300
46.700
57.100
72.200
85.600
99.500
106.700
15.100
17.400
30.000
39.600
48.500
61.400
72.700
84.500
90.700
41
40
38
39
39
38
40
43
42
47
46
44
44
44
44
46
48
47
46
49
52
53
58
59
60
60
61
46
49
52
53
58
59
60
60
61
1.400
1.680
3.080
4.000
4.970
6.300
6.930
7.700
8.400
1.400
1.680
3.080
4.000
4.970
6.300
6.930
7.700
8.400
2.700
3.500
6.600
9.500
11.900
15.000
16.500
19.000
20.600
900 r.p.m.
900 r.p.m.
900 r.p.m.
900 r.p.m.
900 r.p.m. 900 r.p.m.
900 r.p.m.
dB(A)
dB(A)
m3/h
m3/h
W
W
Leaving air temp. °C
700 r.p.m.
700 r.p.m.
700 r.p.m.
700 r.p.m.
700 r.p.m. 700 r.p.m.
700 r.p.m.
NOISE LEVELAT 5 m.
NOISE LEVELAT 5 m.
AIR FLOW
AIR FLOW
HEATING:Water temperature 85/70°C - Entering air temperature 15°C
COOLING:Relative Humidity 55%
Water temperaturea 11/15°C - Entering air temperature 28°C
MOD.
MOD.
0
0
1
1
3
3
4
4
5
5
6
6
7
7
8
8
9
9
89
MOTOR 4/6 POLE(1350/1000 r.p.m.)
RANGE JANUS SIZE ROWS
46 F 4 3
Technicalcharacteristicsofthemaincomponents:• The main casing is manufactured from galvanized prepainted steel (1 mm thick) finished
in light grey (RAL 9002), and it is assembled from three component parts, assembled with
self-tapping screws for quick maintenance on the heat coil. The use of hot dip galvanised
and pre-painted steel ensures consistency and excellent protection against corrosion.
• The standard motor fitted is a hermetically sealed and is maintenance free. The motor is
2 speeds, 3 phase, single voltage 400V/50Hz, protection IP55, class B, with klixon thermal
protection that is triggered in the event of overheating. The rotation speed can be reduced
by passing from delta to star connection.
• Coil with large heating surfaces with copper pipe and in aluminium fins.
• The condensate collection tray is fitted inside the unit. Made from galvanized steel insulated
with polyolefin (PO) foam (class M1).
Reference: 46F43
JANUS identification code
Janus
JANUS unit heaters can be used to economically cool industrial, commercial
and sporting facilities, transforming a traditional heating system using unit
heaters into a system that can also be used in the summer months, significantly
improving the working conditions. The condensate collection tray is built into
the appliance, while two-speed motors are fitted as standard. Upon request,
controls with thermostat can also be supplied. The Janus unit heaters are
made in 4 sizes, each with 3 and 4 row coils, for a total of 8 models, with heat
outputs from 16 to 104 kW and cooling capacities from 5 to 28 kW.
Upon request, sizes 1 to 6 are available with theinnovativeelectronicmotors with extremely low energy consumption, controlled by an inverter
board and identified by ECM. The ECM motors allow to decrease electric
consumption compared to traditional asynchronous motors and they enable
to adjust the air flow continuously and control the ambient temperature with
precision, with further benefits in terms of very low noise levels.
AirConditionerJanus
91
WEIGHT Kg WATER CONTENT Liters
3R 4R 3R 4R526
634
742
1010
390
498
606
874
500
500
525
650
1"
1"
1"
1 ¼"
376
476
576
818
78
76
83
90
71
83
83
100
58
58
58
67
25,0
32,5
42,5
77,0
26,0
34,0
44,5
81,0
2,2
3,4
5,1
9,8
1,7
2,7
4,0
7,6
A B C D E F1 F2 L
46 F 23/2446 F 43/4468 F 63/6468 F 93/94
MODEL
1000
1500
7.5
51
5.3
3.6
19.9
3.7
3.1
21.1
4.2
3.3
20.7
1000
1400
7
51
6.3
4.2
17.9
4.4
3.5
19.6
5.0
3.7
19.0
1000
2500
12
54
9.1
6.2
19.8
6.4
5.2
21.1
7.3
5.5
20.7
1000
2150
10
54
10.6
6.9
17.5
7.5
5.8
19.2
8.6
6.1
18.7
750
3600
14
52
13.8
9.2
19.4
9.8
7.7
20.8
11.3
8.2
20.3
750
3150
13
52
15.9
10.2
17.2
11.3
8.5
19.0
13.0
9.1
18.3
700
6250
20
60
25.0
16.9
19.1
17.6
14.2
20.5
20.1
15.1
20.1
700
5950
18
60
28.2
18.4
17.0
20.0
15.4
18.8
22.8
16.4
18.2
1350
2200
11
59
8.3
27.1
20.4
44.8
19.5
43.5
1350
2000
10
59
9.5
30.4
23.3
52.8
22.5
51.5
1350
3800
16
64
14.1
26.9
34.5
44.2
33.2
43.1
1350
3400
14
64
16.2
30.3
39.7
52.3
38.6
51.3
950
4350
18
60
19.0
28.7
46.3
48.4
45.2
47.6
950
4000
17
60
21.4
32.2
52.0
56.9
51.1
56.2
900
8250
26
66
36.5
29.2
89.5
49.8
86.6
48.7
900
7800
24
66
42.3
32.3
103.6
57.4
100.9
56.3
1000
1500
7.5
51
6.6
29.0
16.1
49.5
15.5
48.2
1000
1400
7
51
7.5
32.3
18.5
57.5
18.0
56.3
1000
2500
12
54
11.0
29.0
26.9
49.2
26.0
48.2
1000
2150
10
54
12.1
32.7
29.6
58.2
29.0
57.3
750
3600
14
52
16.6
29.9
40.3
51.2
39.5
50.4
750
3150
13
52
18.2
33.6
44.0
60.1
43.5
59.6
700
6250
20
60
31.0
30.6
75.9
53.2
73.8
52.1
700
5950
18
60
33.6
34.2
82.0
61.9
80.4
61.0
2.5 ÷ 4
2.5 ÷ 4
3 ÷ 4.5
3 ÷ 4.5
3 ÷ 5
3 ÷ 5
3.5 ÷ 5.5
3.5 ÷ 5.5
JANUS Technical sPecificaTions
HEATING EMISSION
COOLING EMISSION
m
m
r.p.m.
r.p.m.
m3/h
m3/h
m
m
dB(A)
dB(A)
kW
kW Total
kW Total
kW Total
kW
kW
Leaving airtemp. °C
kW Sensible
kW Sensible
kW Sensible
Leaving airtemp. °C
Leaving airtemp. °C
Leaving airtemp. °C
Leaving airtemp. °C
Leaving airtemp. °C
Mounting height
Mounting height
Speed
Speed
Air flow
Air flow
Throw
Throw
Noise level at 5 m
Noise level at 5 m
Watertemperature 45/40°C ∆t 5°C
Watertemperature 7/12°C ∆t 5°C
Watertemperature 11/15°C ∆t 4°C
Watertemperature 9/14°C ∆t 5°C
Watertemperature 85/75°C ∆t 10°C
Watertemperature 90/70°C ∆t 20°C
Entering air temp. +15°C
Entering air temp. +28°C R.H. 55%
Entering air temp. +28°C R.H. 55%
Entering air temp. +28°C R.H. 55%
Entering air temp. +15°C
Entering air temp. +15°C
MODEL
MODEL
46F 23
46F 23
46F 43
46F 43
68F 63
68F 63
68F 93
68F 93
46F 24
46F 24
46F 44
46F 44
68F 64
68F 64
68F 94
68F 94
Dimensions, Weight, Water content
Janus
93
Accessories
Controls
Accessories
External air intake grille suitablewith AE and AES air boxes.
Prepainted steel thickness 1 mm.AG
Ball protection grid.APP
Internal/external air mixing box,manually controlled
(can be motorized by customer).
Prepainted steel thickness 1 mm.
AMS
Delta-Star switchfor two speed Delta-Star motors, 4/6 or 6/8 poles.
Manual three-position switchfor two speed Delta-Star motors, 4/6 or 6/8 poles,
with klixon thermic protection. BS 3-ST with thermostat
Fresh air boxwith manually operated damper
(can be motorized by the customer).
Prepainted steel thickness 1 mm.
Internal/external air mixing boxmanually controlled.
Prepainted steel thickness 1 mm.
Fresh air box.
Prepainted steel thickness 1 mm.
4 way diffuser.To be used
when discharging downflowto create a 4 way discharge pattern.
Wall bracket.
Simple intake hood fitted underneath.Wall bracket included.
Prepainted steel thickness 1 mm.
AES
AM
AE
AD
AMP
ARC
Janus
95
ELEGANTECMair conditioners allow
to heat and cool very economically small and medium areas,
like shops, show rooms, workshops, supermarkets.
The range is made up of 12 models:
RE-ECM version, for heating only, is made up of8models,andPE-ECM version, for heating and cooling, is made up of4models.All models are for ceiling installation and for hot/chilled water supply.
CeilingAirConditionerElegantECM
ElegantE
CM
TheElegantECM series uses an innovative brushless
synchronous permanent magnet electric motor
controlled by an inverter card that is directly
installed on the unit.
The intake of the air is from the bottom side
of the unit and the air supply is from the
4 lateral grids which have individually
controllable louvres for the best distribution
of the air.
The condensate drain is made through an electronically controlled micro-pump, supplied on
every standard PE–ECM model.
Different remote controls of the air flow and of the room temperature are available and it is
possible to control up to 10 units with only one remote control.
All theElegantECM units can be supplied with a wide range of controls
using theModbusRTU-RS485 communication protocol.
Beside the low installation and running cost,
the ElegantECMSabiana air conditioners offer the following advantages:
• they take up a small amount of the valuable space in the room,
there is not any ducting system and the walls are free.
• they are versatile and provide flexibility of installation:
also where there is no false ceiling it is possible to distribute the air evenly.
• they provide easy control and are easily installed.
97
ElegantE
CM
Casingmade of steel on both top and bottom sections
and it is then finished with an epoxy-polyester powder
coating dried at 180°, in white RAL 9016.
The lower casing is also the condensate collection tray.
The components are assembled with screws and so it is possible
to quickly dismantle it for inspection when needed.
OutletgridsThe discharge of the air is obtained through 4 grids on the 4
lateral sides. They are comprised by a frame in which
the louvres are individually adjustable. It is very easy to take off
these grids, allowing for easy maintenance of the coil
and of the condensate tray.
Electronicmotor Three phase permanent magnet brushless electronic motor.
The inverter board that controls the motor operation is powered by 230 Volt,
single-phase and it generates a frequency modulated wave form
power supply. The electric power supply required for the
machine is therefore single-phase with voltage of 230-240V
and frequency of 50-60Hz.
HelicoidalfanThe fan is made with statically and dynamically balanced plastic blades.
Its rational high-capacity profile provides the maximum air volume
with the minimum energy consumption. The fan hub is secured
onto the motor shaft and it is protected by a safety guard.
CoilThe coil is constructed of copper tubes with aluminium fins and steel headers.
The supply and return connections have a female threading,
1” diameter, and they allow the connection either vertically
from above or horizontally from a side.
The coil is supplied in two versions: with 1 row and with 2 rows.
The coil is not suitable for use in corrosive atmosphere or
in environments where aluminium may be subject to corrosion.
Condensatemicro-pump The PE–ECM model for cooling is always supplied with an integral micro-
pump (discharge head 3m, water flow 6l/h). The pump is installed in
the condensate collected tray. This pump controls the level of
the condensate collected in the tray and drain it when necessary.
Construction features
FEMALE
With1ROWCOIL(onlyheating)
With2ROWCOIL(heatingandcooling)
600
540
330
220
600
540
330
220
26 2831 3432 3538 40
0.8 1.81.1 2.41.1 2.41.3 2.7
750
690
480
287
750
690
480
287
750
690
480
300
750
690
480
300
830
770
560
344
830
770
560
344
DIMENSIONS (mm) DIMENSIONS (mm)
A
B
C
D
A
B
C
D
MODEL MODELRE–ECM RE–ECM / PE–ECM
11 21 31 41 12 22 32 42
WEIGHT (kg) WEIGHT (kg)
WATER CONTENT (Liters) WATER CONTENT (Liters)
Dimensions, Weight, Water content
99
ElegantE
CM
247510,40
6,447383432
309011,84
8,151423854
351512,75
9,254454177
399513,7210,5574844108
445014,5711,7595046150
468014,9912,4605147174
181014,9714,250413737
216016,8017,553444059
246018,2420,256474386
278019,6823,2595046121
302020,7125,4615248162
306020,8925,8615248164
18808,7010,550413737
22459,7112,753444059
256010,5014,756474386
289011,2916,7595046121
314011,8518,2615248162
318011,9518,5615248164
132512,6413,048393523
158014,2616,251423836
185015,8119,554454155
209017,1322,557484475
232018,3125,4605147104
250019,2027,7625349136
13807,597,948393523
16458,469,651423836
19259,3211,454454155
217510,0313,057484475
241510,6814,6605147104
260011,1815,9625349136
10059,566,944353116
121510,88
8,848393524
141012,0110,552433937
157012,8811,954454151
173513,7413,356474369
182014,1514,157484481
10455,8811,244353116
12656,6013,848393524
14657,2016,252433937
16357,6718,154454151
18058,1420,256474369
18908,3621,157484481
238017,49
4,847383432
297020,08
6,251423854
338021,71
7,154454177
384023,44
8,2574844108
428025,00
9,2595046150
450025,73
9,7605147174
5 6 7 8 9 10
5 6 7 8 9 10
5 6 7 8 9 10
5 6 7 8 9 10
5 6 7 8 9 10
5 6 7 8 9 10
5 6 7 8 9 10
5 6 7 8 9 10
ELEGANT Technical sPecificaTions
Inverter Power (V)
Inverter Power (V)
Inverter Power (V)
Inverter Power (V)
Air flowHeatingDp HeatingSound power LwSound pressure Lp (*)Sound pressure Lp (**)Fan
Air flowHeatingDp HeatingSound power LwSound pressure Lp (*)Sound pressure Lp (**)Fan
Air flowHeatingDp HeatingSound power LwSound pressure Lp (*)Sound pressure Lp (**)Fan
Air flowHeatingDp HeatingSound power LwSound pressure Lp (*)Sound pressure Lp (**)Fan
m3/hkWkPa
dB(A)dB(A)dB(A)
W
m3/hkWkPa
dB(A)dB(A)dB(A)
W
m3/hkWkPa
dB(A)dB(A)dB(A)
W
m3/hkWkPa
dB(A)dB(A)dB(A)
W
MODEL
MODEL
MODEL
MODEL
RE–ECM 11
RE–ECM 31
RE–ECM 21
RE–ECM 41
RE–ECM 12
RE–ECM 32
RE–ECM 22
RE–ECM 42
HEATING (winter mode)
Entering air temperature: +20°CWater temperature: +70/60°C
The following standard rating conditions are used:
RE-ECMunits(heatingonly)
(*) = Measurement performed at 3 meter from the source, room volume of 500m3, reverberation period of 2 s, directional factor Q=2 (hemisphere sound emission) (**) = Measurement performed at 3 meter from the source, room volume of 1500m3, reverberation period of 2 s, directional factor Q=2 (hemisphere sound emission)
10053,893,149,566,36,944353116
12154,303,58
10,887,68,848393524
14104,653,98
12,018,8
10,552433937
15704,804,23
12,889,3
11,954454151
17355,174,61
13,7410,613,356474369
18205,204,71
14,1510,714,157484481
18106,435,21
14,9716,314,250413737
21607,015,87
16,8019,017,553444059
24607,516,44
18,2421,520,256474386
27807,997,02
19,6824,123,2595046
121
30208,417,50
20,7126,425,4615248
162
30608,527,60
20,8927,025,8615248
164
13255,314,14
12,6412,713,048393523
15805,834,68
14,2615,016,251423836
18506,335,22
15,8117,419,554454155
20906,745,6817,1319,422,557484475
23207,136,1218,3121,525,4605147104
25007,386,4419,2022,927,7625349136
23807,196,40
17,497,64,847383432
29708,097,53
20,089,46,251423854
33808,848,40
21,7111,07,154454177
38409,329,1523,4412,18,2574844108
42809,839,8325,0013,49,2595046150
450010,0710,0725,7314,09,7605147174
5 6 7 8 9 10
5 6 7 8 9 10
5 6 7 8 9 10
5 6 7 8 9 10
ELEGANT Technical sPecificaTions
Inverter Power (V)
Inverter Power (V)
Air flowCooling total emissionCooling sensible emissionHeatingDp CoolingDp HeatingSound power LwSound pressure Lp (*)Sound pressure Lp (**)Fan
Air flowCooling total emissionCooling sensible emissionHeatingDp CoolingDp HeatingSound power LwSound pressure Lp (*)Sound pressure Lp (**)Fan
m3/hkWkWkWkPakPa
dB(A)dB(A)dB(A)
W
m3/hkWkWkWkPakPa
dB(A)dB(A)dB(A)
W
MODEL
MODEL
PE–ECM 12
PE–ECM 32
PE–ECM 22
PE–ECM 42
COOLING (summer mode)
Entering air temperature: +27°C d.b. R.H. 50%Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CWater temperature: +70°C E.W.T. +60°C L.W.T.
The following standard rating conditions are used:
PE-ECMunits(heatingandcooling)
3.5
3.5
4.0
4.5
3.0
3.0
3.5
4.0
3.5
3.8
4.0
4.5
2.5
2.6
3.0
3.5
Maximumheight
(m)
Maximumheight
(m)
Surface
(m)
Surface
(m)
H HR R
HIGH SPEED LOW SPEED
1234
MODEL
101
SabianetmanagementsystemforanetworkofElegantECM
ForeachunitmustbeprovidedtheADCconverterforwallcontrols
ElegantE
CM
3-way valve kit
Comprised of:
- one 3-way valve 3/4" kVs 4,7
- one actuator
- pipe connections
Accessories
Cover panel
To be mounted on the fan guard.
Hanging brackets
Comprised of 4 eye bolts and screws.
1) Washer for screw M8
2) Screw M8 x 16
3) Eye bolt female M8
Power unit for CR-T-ECM and CR-DI-ECM remote control, fitted on the unit
Power unit for CR-T-ECM and CR-DI-ECM remote control, not fitted on the unit
UPM-ECMUPS-ECM
Hardware/software supervisory system (to be used with MB board only)
Router for Sabianet
Relay output board for Sabianet
SabianetROUTER-S
SIOS
NOTES: for more details about the Controls, see Page 225.
ADC signal converter fitted on the unit
ADC signal converter supplied with separate packaging
3 speed control
3 speed control with electronic thermostat and summer/winter switch
Automatic speed control with electronic thermostat to be mounted in the DIN 503 box (for units with valves)
Electromechanical thermostat with summer/winter switch (only for 2 pipe units)
ADC-MADC-SMO-3VTMO-T
TMO-503-SV2T2T
Wall electronic controls
MB electronic board fitted on the unit
MB electronic board supplied with separate packaging
Wall control (to be used with MBE board only)
Multifunction control (to be used with MB board only)
MBE-MMBE-ST-MB
PSM-DI
Electronic controls for MBE boards
Continuous fan speed control with electronic thermostat and summer/winter switch
Continuous fan speed control with electronic thermostat and summer/winter switch
CR-T-ECMCR-DI-ECM
Wall electronic controlsECMrangecontrols
103
105
107
109
In2004 a new generation
of cassettes was introduced, designed for
installation in false ceilings, featuring a modern design,
different colours and different aesthetic solutions,
leading the company to soon become
one of the European leaders in the production of fan coils
and helping itexpand its market to other continents.
In2009, Sabiana was the first company
in the world to introduceinverter-drivenbrushless motors in its cassette units, with power consumption
below 10 watts in the most common operating conditions.
Continuous adjustment of air flow-rate also means
much more precise control over indoor temperature.
The following pages illustrate all the solutions
that are currently available, both
featuring traditional asynchronous motors
and electronically controlled motors, with
performance certified by the independent
instituteEUROVENT.
Sabiana has been makingfancoilssince1980,units that stand out for their attractive design and
very low noise and power consumption, responding to current demand
forenergysavingandindoorcomfort.
In1994 the company acquired the patent to exclusively
manufacture one of the most innovative components ever developed
for hydronic terminal units, one that is still widely used today
and is part of a product designed to air-condition a wide variety
of different environments, with the result of significantly improving indoorairquality(IAQ) and, by reducing the amount
of outside air needed in the system, decreasing air-conditioning costs.
The name of this electronic filter-Crystall- is quite symbolic,
and is used to identify this specific type of solution.
FanCoils
Eurovent CertificationSabiana obtained the Eurovent certification in 1996.
Eurovent is an independent bodyrecognized in all Europe that ensures
total reliability and transparency of performances.
www.eurovent-certification.comwww.certiflash.com
111
The 5 models
(for wall and ceiling installation,
with casing and concealed)
and the different available coils
(with three or four rows for
two pipe systems, one or two rows
for four pipe systems) offer
great installation flexibility and allow the use
of low temperature hot water, in line with the development
of modern boilers and heat pumps.
As a special option, the Carisma range can be fitted with the Crystall
patented electronic filter featuring a class D rating according to Standard UNI 11254,
with similar performances to the initial ones of a traditional mechanical filter
featuring a class F9 rating according to Standard UNI EN 779.
A full range of controls is available,
including the innovative Free patented wireless system, for rapidly obtaining
correct ambient temperature and desired performances and comfort.
The Carisma model
is complemented with a full range
of accessories: various types
of adjustment valves, sturdy support feet,
rear covering panel for glass installation,
additional electric heater,
auxiliary condensate pump,
fresh air intake louver, air inlet/outlet
diffusers for concealed systems.
CARISMA is the result of a great commitment of energy and resources,
with the aim of offering an innovative product in terms of
design, performance, low noise, energy saving and functionality.
Upon request, innovativeelectronicmotors with
extremely low energy consumption, controlled by an inverter board
and identified by ECM, are available with centrifugal and tangential fan.
The ECM motors allow electrical consumption to be decreased
by more than 50% compared to traditional asynchronous motors.
They enable continuous air flow control and precise control
over the ambient temperature, with further benefits in terms of very low
noise levels thanks to the reduced average working speed.
FanCoilUnitCarisma
Caris
ma
113
Technicalcharacteristicsofthemaincomponents:Outercasing: made with strong synthetic lateral corners and from galvanized and pre-
painted front steel panel. The plastic top grid has fixed louvres and is reversible in order to
distribute the air in two different directions.
Standardcolours:
• Lateral corners and top grid: PantoneCoolGrey1C(lightgrey)
• Front panel: RAL9003(white)
• Other colours on request.
Innercasing: made from galvanized steel insulated with polyolefin (PO) foam (class M1).
Filter: polypropylene cellular fabric regenerating filter. The filter frame of galvanized steel is
inserted into special plastic sliding guides fastened to the internal structure for easy insertion
and removal of the filter. Filter presence is highlighted by a plastic front cover featuring the
same colour as the top grid.
Fanassembly: the fans have aluminium or plastic blades directly keyed on the motor
with double aspiration and they are dynamically and statically balanced during manufacture
in order to have an extremely quiet operation.
Electricmotor: the motor is wired for single phase and has six speeds, three of which
are connected, with capacitor. The motor is fitted on sealed for life bearings and is secured
on anti-vibration and self-lubricating mountings. Internal thermal protection with automatic
reset, protection IP 20, class B.
Coil: it is manufactured from drawn copper tube and the aluminium fins are mechanically
bonded onto the tube by an expansion process. The coil has two 1/2inch BSP internal
connections and 1/8 inch BSP air vent and drain. The coil is not suitable for use in corrosive
atmosphere or in environments where aluminium may be subject to corrosion.
Flowandreturnpipeconnectionsaresituatedatthesameendontheleftsidelookingat
theunit.Onrequestwecandeliverthe
unitwiththeconnectionsontherightend
side.Thisoperationcanalsobeeasily
carriedoutonsiteduring installation.
Condensatecollectiontray: made
from plastic with an “L”-shaped plastic
fitted on the inner casing; in the MO-MVB
and IV-IO model the tray is insulated with
polyolefin (PO) foam (class M1).
The outside diameter of the condensate
discharge pipe is 15 mm.
Caris
maCRC
Range includes 9airflowrates (from 105 to 1500 m3/h)
and 5models (for wall and ceiling installation,
with casing and concealed), each equipped with 3 or 4 row coil and
with the possibility to add a 1 or 2 row coil for 4 pipe systems.
It is the most comprehensive range, perfectly suited to meet
all of the climate control needs of work environments such as offices,
shops, restaurants and hotel rooms featuring ducted installations
with available pressure upto50Pa.
FanCoilUnitwithCentrifugalFanwithAsynchronousMotor
CarismaCRC
115
60 60
158 158
7144
125
133
C
100
A
530
630
A
B
170
100
7144
125
133
158 158C
60 60
A
530
A
B
170
153
1711
9 *
7144
125
133
F10
D
E*12 12
511
D22 22
29
12
G
H
Ø 15 ext.
230
100
12
15,516,216,716,016,712,212,913,412,713,4
13,914,615,114,415,110,611,311,811,111,8
17,218,018,618,018,813,614,415,014,415,2
15,416,216,816,217,011,812,613,212,613,4
21,422,623,322,423,617,118,319,018,119,3
19,120,321,020,121,315,316,517,216,317,5
22,523,724,423,524,718,119,320,019,120,3
20,221,422,121,222,416,317,518,217,318,5
26,928,429,328,129,621,923,424,323,124,6
24,125,626,525,326,819,621,122,020,822,3
27,729,230,129,030,522,824,325,224,125,6
24,926,427,326,227,720,522,022,921,823,3
32,133,935,033,635,427,028,829,928,530,3
28,830,631,730,332,124,226,027,125,727,5
35,737,538,637,239,030,232,033,131,733,5
32,033,834,933,535,327,128,930,028,630,4
35,937,738,837,439,230,432,233,331,933,7
32,234,035,133,735,527,329,130,228,830,6
P
R
S
321
T
H
B
230
Ø 15 ext.
Ø 1/2" F
WATER OUTLET
WATER
INLET
Ø 1/2" F
M
37
O
N
T
Ø 15 ext.
BH
230
WATER
INLETWATER
OUTLET
Ø 15 ext.
M
37
O
N
U
GH
230
Ø 1/2" F
WATER
INLETWATER
OUTLET
P
R
S
321
U
H
G
230
Ø 15 ext.
Ø 1/2" F
WATER OUTLET
WATER
INLET
ROW
S
34
+1+2
ROW
SRO
WS
MV
MO-MVB
IV-IO
WEIGHT WITH PACKAGING WEighT WiThouT pACKAging
6702253543743303542182051452604601851054755565
0,50,70,20,4
7702254544744304542182051452604601851054755565
0,60,80,20,4
9852256696896456692182051452604601851054755565
0,91,30,30,6
9852256696896456692182051452604601851054755565
0,91,30,30,6
12002258849048608842182051452604601851054755565
1,31,70,40,8
12002258849048608842182051452604601851054755565
1,62,20,51,0
1415225
10991119107510992182051452604601851054755565
1,72,40,51,0
141525510991119107510992482351702704502101104658595
1,92,80,61,2
141525510991119107510992482351702704502101104658595
1,92,80,61,2
ABCDEFGHMNOPRSTU
33+13+2
44+1
33+13+2
44+1
MODEL
MODEL
MODEL
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
1 12 23 34 45 56 67 78 89 9
3 or 4 row coils 3 or 4 row coilsHeating
additional coil(1 or 2 rows)
Heatingadditional coil(1 or 2 rows)
Coilconnections
MVandMO-MVBmodel IV-IOmodel
Weight(kg)
Dimensions, Weight, Water content
Caris
maCRC
Watercontent(litres)
Dimension(mm)
MVmodel
MO-MVBmodel
IV-IOmodel
Feet(optional)
Auxiliarycondensatetray(optional)
*Supplyframedimension=Ex119mm
Dimensions, Weight, Water content
Coilconnectionsontheleft
117
1050,670,510,821,381,91,5163223
0,630,7
1250,780,600,961,622,52,0193425
0,710,9
1500,890,681,101,863,22,6213627
0,791,0
1751,020,791,272,154,03,3253930
0,891,3
1951,110,871,392,364,73,9294233
0,961,5
2201,230,971,552,635,64,7334536
1,041,7
1451,010,741,181,984,93,9143021
0,941,7
1701,130,831,342,246,14,9163324
1,042,0
2201,431,071,722,889,27,5224031
1,252,8
2501,591,191,923,2211,09,2264334
1,363,3
2951,811,382,203,6913,911,6324738
1,524,0
3402,041,572,504,1917,214,6405142
1,684,8
1851,340,961,562,603,72,9153122
1,353,9
2351,651,201,943,235,34,2203627
1,595,2
2701,891,382,233,736,75,4254031
1,776,3
3252,211,622,634,408,97,0324536
2,007,8
3852,571,903,075,1411,59,2414940
2,269,7
4402,882,143,465,8014,111,3495243
2,4811,4
1851,320,951,542,573,42,5142718
1,343,9
2651,831,342,163,626,14,6213324
1,736,0
3352,281,682,724,569,06,9283930
2,068,2
4002,651,973,175,3211,79,0344334
2,3210,1
4853,122,343,766,3315,512,2444738
2,6512,8
5703,562,694,347,3019,615,6575243
2,8814,8
2501,791,302,063,447,35,7182617
1,771,2
3152,191,602,534,2310,48,3223122
2,071,6
4202,832,083,305,5116,313,1323728
2,532,3
4953,252,403,816,3720,817,0394132
2,832,8
5453,542,634,176,9724,219,9464334
3,033,2
6504,093,074,838,0731,325,7614839
3,423,9
4152,832,073,395,6614,411,0373728
2,503,2
5053,382,494,076,8119,715,2464233
2,874,1
5903,862,864,697,8524,819,5554637
3,194,9
6804,383,275,358,9830,924,7674940
3,545,8
7604,793,605,889,9036,229,3785243
3,816,7
8305,133,876,35
10,6840,933,5885445
4,047,4
4453,032,223,555,939,57,7443829
2,893,4
5353,562,624,207,0212,510,3544233
3,294,3
6304,083,034,868,1215,913,3664738
3,685,2
7354,643,475,559,3020,016,9795142
4,096,3
8405,173,896,19
10,3824,220,5925445
4,497,4
9255,584,236,7111,2627,723,71035647
4,798,3
5103,272,434,036,785,24,1473930
3,033,7
6554,033,045,068,557,66,2624536
3,605,0
8154,803,666,11
10,3710,38,4815041
4,176,5
10205,734,437,3612,5214,111,41055647
4,868,5
11006,064,717,84
13,3415,612,71165849
5,119,3
12006,475,068,4314,3617,514,51306051
5,4110,3
7354,423,365,599,479,07,2784738
3,895,8
8304,883,726,2210,5510,68,7925041
4,226,7
9805,574,297,14
12,1313,411,11085445
4,748,2
12106,545,118,5314,5217,814,81345849
5,4610,5
13657,135,639,38
16,0220,717,01526253
5,9012,0
15007,606,0510,0817,2323,219,31766455
6,2313,2
1 2 (E)
MIN
3 4 (E)
MED
5 6 (E)
MAX
1 2 (E)
MIN
3 4 (E)
MED
5 6 (E)
MAX
1 2 (E)
MIN
3 4 (E)
MED
5 6 (E)
MAX
1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6 1 2 (E)
MIN
3 4 (E)
MED
5 (E) 6
MAX
1 (E)
MIN
2 3 (E)
MED
4 5 (E)
MAX
6
1 (E)
MIN
2 3 4 (E)
MED
5 6 (E)
MAX
1 (E)
MIN
2 3 (E)
MED
4 5 (E)
MAX
6 1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6Speed
Speed
Speed
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*) Heating (E) Dp Heat. (E)
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*) Heating (E) Dp Heat. (E)
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*) Heating (E) Dp Heat. (E)
1 row heating additionalcoil (Water 70/60°C)
1 row heating additionalcoil (Water 70/60°C)
1 row heating additionalcoil (Water 70/60°C)
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
kWkPa
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
kWkPa
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
kWkPa
MODEL
MODEL
MODEL
CRC 14
CRC 44
CRC 74
CRC 24
CRC 54
CRC 84
CRC 34
CRC 64
CRC 94
(E) = Eurovent certified performance. MIN-MED-MAX = Standard connected speeds.(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
Certification
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
2pipeunits.The following standard rating conditions are used:
www.eurovent-certification.comwww.certiflash.com
Unitswith4rowcoil
1050,590,470,761,310,90,8163223
0,630,7
1250,680,540,901,531,10,9193425
0,710,9
1500,770,621,021,751,41,2213627
0,791,0
1750,860,711,151,991,71,4253930
0,891,3
1950,940,781,262,182,01,7294233
0,961,5
2201,030,861,392,422,32,0334536
1,041,7
1450,910,691,121,902,52,1143021
0,941,7
1701,010,771,272,143,02,6163324
1,042,0
2201,250,971,592,704,43,7224031
1,252,8
2501,381,081,773,005,34,5264334
1,363,3
2951,561,242,023,446,55,5324738
1,524,0
3401,741,402,283,897,96,7405142
1,684,8
1851,280,941,522,546,65,6153122
1,353,9
2351,571,151,873,149,48,0203627
1,595,2
2701,781,322,153,6111,810,0254031
1,776,3
3252,071,552,524,2415,413,1324536
2,007,8
3852,391,802,924,9219,716,7414940
2,269,7
4402,662,023,275,5223,820,2495243
2,4811,4
1851,270,931,502,516,55,5142718
1,343,9
2651,731,282,093,5111,29,5213324
1,736,0
3352,141,602,614,3616,213,8283930
2,068,2
4002,461,863,025,0820,817,7344334
2,3210,1
4852,872,193,566,0027,223,1444738
2,6512,8
5703,242,514,066,8733,828,7575243
2,8814,8
2501,681,241,983,324,13,5182617
1,771,2
3152,031,512,424,075,84,9223122
2,071,6
4202,581,943,135,268,87,5323728
2,532,3
4952,942,233,596,0411,19,4394132
2,832,8
5453,182,433,896,5412,710,8464334
3,033,2
6503,642,824,507,5716,213,8614839
3,423,9
4152,541,913,075,178,67,3373728
2,503,2
5052,992,273,666,1511,49,7464233
2,874,1
5903,372,594,136,9614,112,0554637
3,194,9
6803,772,934,687,8717,214,6674940
3,545,8
7604,093,205,098,6119,816,8785243
3,816,7
8304,353,445,459,2222,118,8885445
4,047,4
4452,872,133,415,7112,310,5443829
2,893,4
5353,342,504,016,7216,213,8544233
3,294,3
6303,802,874,607,6720,317,3664738
3,685,2
7354,293,275,198,7325,121,3795142
4,096,3
8404,763,665,809,7630,125,6925445
4,497,4
9255,113,956,27
10,5534,229,11035647
4,798,3
5103,062,323,846,497,36,2473930
3,033,7
6553,742,884,808,1110,38,8624536
3,605,0
8154,413,445,619,6713,811,8815041
4,176,5
10205,194,126,74
11,6318,415,61055647
4,868,5
11005,474,377,1512,3620,217,31165849
5,119,3
12005,824,687,66
13,2522,519,21306051
5,4110,3
7354,083,165,218,8711,910,2784738
3,895,8
8304,473,495,719,8213,812,0925041
4,226,7
9805,064,006,5411,2917,314,91085445
4,748,2
12105,874,737,72
13,3922,419,11345849
5,4610,5
13656,365,198,4714,7025,922,51526253
5,9012,0
15006,745,559,06
15,7428,624,61766455
6,2313,2
1 2 (E)
MIN
3 4 (E)
MED
5 6 (E)
MAX
1 2 (E)
MIN
3 4 (E)
MED
5 6 (E)
MAX
1 2 (E)
MIN
3 4 (E)
MED
5 6 (E)
MAX
1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6 1 2 (E)
MIN
3 4 (E)
MED
5 (E) 6
MAX
1 (E)
MIN
2 3 (E)
MED
4 5 (E)
MAX
6
1 (E)
MIN
2 3 4 (E)
MED
5 6 (E)
MAX
1 (E)
MIN
2 3 (E)
MED
4 5 (E)
MAX
6 1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6Speed
Speed
Speed
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*) Heating (E) Dp Heat. (E)
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*) Heating (E) Dp Heat. (E)
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*) Heating (E) Dp Heat. (E)
1 row heating additionalcoil (Water 70/60°C)
1 row heating additionalcoil (Water 70/60°C)
1 row heating additionalcoil (Water 70/60°C)
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
kWkPa
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
kWkPa
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
kWkPa
MODEL
MODEL
MODEL
CRC 13
CRC 43
CRC 73
CRC 23
CRC 53
CRC 83
CRC 33
CRC 63
CRC 93
(E) = Eurovent certified performance. MIN-MED-MAX = Standard connected speeds.(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
Certification
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
2pipeunits.The following standard rating conditions are used:
www.eurovent-certification.comwww.certiflash.com
Unitswith3rowcoil Caris
maCRC
119
StandardMV-MVBmodels
StandardMV,MO-MVBandIV-IOmodels
FreeSabianawirelesscontrolsystem
The air is sucked in and firstpasses a mechanical pre-filter, which stops awayparticles of more than50 μm (dust, insects,etc.) (PHASE1).
Then the smallestparticles (50÷0.01 μm)are exposed to anintensive ionic fieldand are polarized(PHASE2).
The charged particlespassing through thesecond filter section, arepushed back by the anodeand attracted by the collectionsurfaces by a strong, inductedmagnetic field (PHASE3).
The air which leaves the unit is free frompolluting particles.
INLETOF POLLUTED AIR
OUTLETOF CLEAN AIR
PHASE
3
PHASE
2
PHASE
1
Air withoutparticles < 1 μm
Electrostaticfilter
Air withoutparticles ≥ 50 μmPre-filter
Collectionsurface
Inductedanode
Polarizedelectrode
Ionic field
Eliminationof the biggestparticles
IAQ accessory (only for CRC/CRC-ECM version)
Operating principleof the Crystall
electronic filter
The CrystallSabiana electrostatic filter matches the need for better
air conditioning with the concepts of space and design.
With this filter the various stages of air treatment are combined in one
appliance.
Thanks to this new patented filter (efficiency
compliant with new Standard UNI 11254), air
pollutants such as cigarette smoke, dust (PM10,
PM2.5), pollen and most biological organisms
areeliminated.
In addition, as fresh air is not being introduced to
obtain the best climatic conditions, there are
consequential energy savings.
Ambientair intake
CRC Centrifugal fan
Pre-filter
Coil
Casing
Emission of conditioned air
Electrostatic filter
Caris
maCRC
NOTES: for more details about the Controls, see Page 225. for full list of main Accessories, see Page 235.
Hardware/software supervisory system (to be used with MB board only)
Router for Sabianet
Relay output board for Sabianet
SabianetROUTER-S
SIOS
N.B.: if the electrostatic filter or the electric heater is mounted, use the "IAQ" controls.
N.B.: if the electrostatic filter or the electric heater is mounted, use the "IAQ" controls.
3 speed control
3 speed control with electronic thermostat and manual summer/winter switch
3 speed control with electronic thermostat and centralized summer/winter switch
Automatic 3 speed control with electronic thermostat and summer/winter switch
CBCB-TCB-C
CB-AU
Electronic controls included
3 speed control
3 speed control with electronic thermostat and manual summer/winter switch
3 speed control with electronic thermostat and summer/winter switch
Automatic speed control with electronic thermostat and summer/winter switch
Automatic speed control with electronic thermostat, summer/winter switch and liquid crystal display
Automatic speed control with electronic thermostat to be mounted in the DIN 503 box (for units with valves)
Electromechanical thermostat with summer/winter switch (only for 2 pipe units)
MO-3VCR-T
TMO-TTMO-T-AU
TMO-DI
TMO-503-SV2T2T
Wall electronic controls
Remote control to be used with electronic boards described at Page 228Free-Com
MB electronic board fitted on the unit
MB electronic board supplied with separate packaging
Wall control (to be used with MB board only)
RT03 infra-red remote control with fitted receiver, for MV/MO-MVB models (to be used with MB board only)
Control fitted on the unit, for MV/MVB models with left connections (available with right connections, to be used with MB board only)
Control supplied with separate packaging, for MV/MVB models with left connections (available with right connections, to be used with MB board only)
RT03 infra-red remote control with receiver supplied with separate packaging (to be used with MB board only)
RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Receiver for RT03 infra-red remote control fitted on the unit, for MV/MO-MVB models (to be used with MB board only)
Receiver for RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Multifunction control (to be used with MB board only)
MB-MMB-ST-MB
RM-RT03
T-MB-M
T-MB-S
RS-RT03RT03RM
RSPSM-DI
Electronic controls for MB boards
Sabianetmanagementsystemforanetworkoffancoils
121
Technicalcharacteristicsofthemaincomponents:ForthetechnicalcharacteristicsofthevariouscomponentsrefertoCarismaCRCFanCoilUnit,exceptforElectronicmotor:
TheECMrange makes use of the excellent experience
gained with the SkyStar Cassette fan coils with inverter board,
first in the world in production since 2009, and which have had great success
on all markets.
The innovative brushless and sensorless type synchronous electronic motor
with permanent magnets, is controlled by an inverter board designed
and developed in Italy. The board is mounted on the unit, closed
to the motor, without the need to be cooled down by the
air flow.
The air flow rate can be
varied incontinuously by means
of a 1-10 V signal generated
by Sabiana controls
or by independent control systems.
The continuous air flow control
improves the acoustic comfort and allows
a more punctual reply to the variation of the thermal loads and a greater stability
of the requested ambient temperature.
The extreme efficiency, also at low speed, makes possible a great reduction
in electric consumption (50% less in comparison to CRC AC motor)
with absorption values under normal operating conditions
that donotexceed16Watt. The excellent values of the CRC range in terms of
sound levels have been maintained inallworkingconditions,without any resonance phenomenon at any frequency.
The full compliance with the Electromagnetic Compatibility Directive
and with the other severe Standards in force is certified by an independent institute.
three phase permanent magnet brushless electronic
motor that is controlled with current reconstructed according to a BLAC sinusoidal wave.
The inverter board that controls the motor operation
is powered by 230 Volt, single-phase and, with a switchingsystem, it generates
a three-phase frequency modulated, wave form power supply.
The electric power supply required for the machine
is therefore single-phase with voltage of 230-240V and frequency of 50-60Hz.
Range includes 5airflowrates (from 115 to 1395 m3/h)
and 5models (for wall and ceiling installation,
with casing and concealed), each equipped with 3 or 4 row coil and
with the possibility to add a 1 or 2 row coil for 4 pipe systems.
This is the series with thelowestelectricalconsumptionin relation to both heat performance as well as working static performance
and is particularly suited to satisfying the strictest energy consumption
needsofclassA buildings, and to ensuring excellent acoustic comfort.
FanCoilUnitwithCentrifugalFanwithECBrushlessElectronicMotorandInverterBoard
CarismaCRC-ECM
Caris
maCRC-ECM
123
15,416,216,816,217,011,812,613,212,613,4
20,221,422,121,222,416,317,518,217,318,5
24,926,427,326,227,720,522,022,921,823,3
28,830,631,730,332,124,226,027,125,727,5
32,234,035,133,735,527,329,130,228,830,6
17,218,018,618,018,813,614,415,014,415,2
22,523,724,423,524,718,119,320,019,120,3
27,729,230,129,030,522,824,325,224,125,6
32,133,935,033,635,427,028,829,928,530,3
35,937,738,837,439,230,432,233,331,933,7
60 60
158 158
7144
125
133
C
100
A
530
630
A
B
170
100
7144
125
133
158 158C
60 60
A
530
A
B
170
153
1711
9 *
7144
125
133
F10
D
E*12 12
511
D22 22
29
12
G
H
Ø 15 ext.
230
100
12
ROW
S
34
+1+2
ROW
SRO
WS
MV
MO-MVB
IV-IO
WEIGHT WITH PACKAGING WEighT WiThouT pACKAging
7702254544744304542182051452604601851054755565
0,60,80,20,4
9852256696896456692182051452604601851054755565
0,91,30,30,6
12002258849048608842182051452604601851054755565
1,62,20,51,0
1415225
10991119107510992182051452604601851054755565
1,72,40,51,0
141525510991119107510992482351702704502101104658595
1,92,80,61,2
ABCDEFGHMNOPRSTU
33+13+2
44+1
33+13+2
44+1
MODEL
MODEL
MODEL
9
9
7
7
6
6
4
4
2
2
2 24 46 67 79 9
P
R
S
321
T
H
B
230
Ø 15 ext.
Ø 1/2" F
WATER OUTLET
WATER
INLET
Ø 1/2" F
M
37
O
N
T
Ø 15 ext.
BH
230
WATER
INLETWATER
OUTLET
Ø 15 ext.
M
37
O
N
U
GH
230
Ø 1/2" F
WATER
INLETWATER
OUTLET
P
R
S
321
U
H
G
230
Ø 15 ext.
Ø 1/2" F
WATER OUTLET
WATER
INLET
3 or 4 row coils 3 or 4 row coilsHeating
additional coil(1 or 2 rows)
Heatingadditional coil(1 or 2 rows)
Coilconnections
MVandMO-MVBmodel IV-IOmodel
Weight(kg)
Dimensions, Weight, Water content
Caris
maCRC-ECM
Watercontent(litres)
Feet(optional)
Auxiliarycondensatetray(optional)
*Supplyframedimension=Ex119mm
Dimensions, Weight, Water content
Coilconnectionsontheleft
MVmodel
MO-MVBmodel
IV-IOmodel
Dimension(mm)
125
5753,612,714,507,586,35,216,04435
3,404,6
7554,523,435,739,699,37,7
25,05041
4,086,3
9105,254,036,7011,3712,19,941,05546
4,627,8
11456,254,878,12
13,8216,513,565,06051
5,3510,1
13657,145,639,3916,0320,817,099,06455
5,9812,3
AA
BB
3802,621,913,095,167,36,09,03728
2,652,9
4753,212,363,826,3810,58,5
13,04334
3,103,9
5853,842,844,617,7314,311,818,54839
3,564,9
7354,643,475,619,3920,016,728,55344
4,136,4
8755,344,036,5110,9325,621,041,05748
4,637,8
AA
BB
6053,472,654,457,558,97,716,04435
3,404,6
7854,253,315,539,4012,711,025,05041
4,086,3
9454,863,836,4110,9416,113,941,05546
4,627,8
11755,674,567,6213,0621,118,365,06051
5,3510,1
13956,365,208,6914,9525,922,599,06455
5,9812,3
4002,611,933,085,1610,58,49,03728
2,652,9
5003,142,353,766,3014,511,9134334
3,103,9
6103,702,794,477,5019,416,118,54839
3,564,9
7554,393,355,328,9426,121,528,55344
4,136,4
8904,983,846,0910,2532,626,841,05748
4,637,8
3051,971,472,353,955,54,57,03324
2,001,5
3952,451,842,964,978,06,710,03829
2,402,1
4952,942,233,596,0411,19,215,04435
2,802,8
6103,462,674,257,1714,812,122,04940
3,243,6
7353,993,114,958,3719,015,732,05445
3,684,5
2101,421,041,702,857,96,66,03021
1,474,5
2801,801,342,203,7012,09,99,03627
1,796,4
3502,191,652,704,5517,013,812,04233
2,118,5
4302,581,963,215,4322,618,217,04738
2,4210,9
5152,972,283,746,3328,923,925,05142
2,7413,6
1200,740,560,921,551,81,47,03021
0,811,3
1700,980,751,242,102,92,59,03627
1,041,9
2201,190,931,532,614,03,411,04132
1,232,6
2701,391,101,813,095,34,514,54738
1,423,4
3301,611,302,133,646,95,721,05142
1,634,3
CC
AB
AA
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
2902,061,492,434,058,26,57,03324
2,001,5
3752,611,903,125,2112,410,210,03829
2,402,1
4753,202,353,876,4817,814,915,04435
2,802,8
5903,862,864,717,9024,820,422,04940
3,243,6
7204,543,415,609,4333,026,932,05445
3,684,5
2001,441,041,702,834,03,06,03021
1,474,5
2651,841,352,193,676,14,89,03627
1,796,4
3402,281,682,754,598,97,212,04233
2,118,5
4152,732,043,315,5712,210,017,04738
2,4210,9
5053,192,413,916,6016,113,525,05142
2,7413,6
1150,780,570,941,573,22,67,03021
0,811,3
1601,070,791,302,185,54,69,03627
1,041,9
2101,330,991,632,758,06,511,04132
1,232,6
2601,591,201,983,3311,09,1
14,54738
1,423,4
3251,881,442,374,0114,812,621,05142
1,634,3
CC
AB
AA
Inverter Power (V)
Speed
Inverter Power (V)
Speed
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*) Heating (E) Dp Heat. (E)Energy classification FCEER (**)Energy classification FCCOP (***)
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*) Heating (E) Dp Heat. (E)Energy classification FCEER (**)Energy classification FCCOP (***)
1 row heating additionalcoil (Water 70/60°C)
1 row heating additionalcoil (Water 70/60°C)
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
kWkPa
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
kWkPa
MODEL
MODEL
CRC–ECM 24
CRC–ECM 74
CRC–ECM 44
CRC–ECM 94
CRC–ECM 64
(E) = Eurovent certified performance. (*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec. (**) FCEER = Energy classification in Cooling. (***) FCCOP= Energy classification in Heating.
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
Inverter Power (V)
Speed
Inverter Power (V)
Speed
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*) Heating (E) Dp Heat. (E)Energy classification FCEER (**)Energy classification FCCOP (***)
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*) Heating (E) Dp Heat. (E)Energy classification FCEER (**)Energy classification FCCOP (***)
1 row heating additionalcoil (Water 70/60°C)
1 row heating additionalcoil (Water 70/60°C)
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
kWkPa
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
kWkPa
MODEL
MODEL
CRC–ECM 23
CRC–ECM 73
CRC–ECM 43
CRC–ECM 93
CRC–ECM 63
(E) = Eurovent certified performance. (*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec. (**) FCEER = Energy classification in Cooling. (***) FCCOP= Energy classification in Heating.
(E)(E)
(E)(E)
(E)(E)
(E)(E)
Certificationwww.eurovent-certification.com
www.certiflash.com
Certificationwww.eurovent-certification.com
www.certiflash.com
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
2pipeunits.The following standard rating conditions are used:
Unitswith4rowcoil
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
2pipeunits.The following standard rating conditions are used:
Unitswith3rowcoil
Caris
maCRC-ECM
127
CB – T – ECMcontrol
CR – T – ECMcontrol
and Power Unit
MV-MVBmodels
MV,MO-MVBandIV-IOmodels
NOTES: for more details about the Controls, see Page 225. for full list of main Accessories, see Page 235.
Caris
maCRC-ECM
Continuous fan speed control with electronic thermostat and summer/winter switchCB-T-ECM
Electronic controls included
Continuous fan speed control with electronic thermostat and summer/winter switch
Continuous fan speed control with electronic thermostat and summer/winter switch
Power unit for CR-T-ECM and CR-DI-ECM remote control, fitted on the unit
Power unit for CR-T-ECM and CR-DI-ECM remote control, not fitted on the unit
CR-T-ECMCR-DI-ECMUPM-ECMUPS-ECM
Wall electronic controls
Electronic controls for MB boards
N.B.: if the electrostatic filter is mounted (CRC–ECM only), use the "IAQ" controls.
Hardware/software supervisory system (to be used with MB board only)
Router for Sabianet
Relay output board for Sabianet
SabianetROUTER-S
SIOS
Sabianetmanagementsystemforanetworkoffancoils
MB electronic board fitted on the unit
MB electronic board supplied with separate packaging
Wall control (to be used with MB board only)
RT03 infra-red remote control with fitted receiver, for MV/MO-MVB models (to be used with MB board only)
Control fitted on the unit, for MV/MVB models with left connections (available with right connections, to be used with MB board only)
Control supplied with separate packaging, for MV/MVB models with left connections (available with right connections, to be used with MB board only)
RT03 infra-red remote control with receiver supplied with separate packaging (to be used with MB board only)
RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Receiver for RT03 infra-red remote control fitted on the unit, for MV/MO-MVB models (to be used with MB board only)
Receiver for RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Multifunction control (to be used with MB board only)
MB-ECM-MMB-ECM-S
T-MB
RM-RT03
T-MB-M
T-MB-S
RS-RT03RT03RM
RSPSM-DI
129
Technicalcharacteristicsofthemaincomponents:Outercasing: made with strong synthetic lateral corners and from galvanized and pre-
painted front steel panel. The plastic top grid has fixed louvres and is reversible in order to
distribute the air in two different directions.
Standardcolours:
• Lateral corners and top grid: PantoneCoolGrey1C(lightgrey)
• Front panel: RAL9003(white)
• Other colours on request.
Innercasing: made from galvanized steel insulated with polyolefin (PO) foam (class M1).
Filter: polypropylene cellular fabric regenerating filter. The filter frame of galvanized steel is
inserted into special plastic sliding guides fastened to the internal structure for easy insertion
and removal of the filter. Filter presence is highlighted by a plastic front cover featuring the
same colour as the top grid.
Fanassembly: the tangential fan assembly is composed of two fan shrouds: an external
one in ABS and an internal one of perforated, shaped steel. The fan has an external diameter
of 120mm and is the length of the coil. The fins are concave and are positioned in a spiral
shape along the whole length of the fan.
Electricmotor: the motor is wired for single phase and has six speeds, three of which
are connected, with capacitor. The motor is fitted on sealed for life bearings and is secured
on anti-vibration and self-lubricating mountings. Internal thermal protection with automatic
reset, protection IP 20, class B.
Coil: it is manufactured from drawn copper tube and the aluminium fins are mechanically
bonded onto the tube by an expansion process. The coil has two 1/2inch BSP internal
connections and 1/8 inch BSP air vent and drain. The coil is not suitable for use in corrosive
atmosphere or in environments where aluminium may be subject to corrosion.
Flowandreturnpipeconnectionsaresituatedatthesameendontheleftsidelooking
attheunit.Onrequestwecandelivertheunitwiththeconnectionsontherightendside:
thismustbespecifiedontheorderas
thisoperationcannotbecarriedouton
siteduringinstallation.
Condensatecollectiontray: made
from plastic with an “L”-shaped plastic
fitted on the inner casing; in the MO-MVB
and IV-IO model the tray is insulated with
polyolefin (PO) foam (class M1).
The outside diameter of the condensate
discharge pipe is 15 mm.
Range includes 6airflowrates (from 90 to 945 m3/h)
and 5models (for wall and ceiling installation,
with casing and concealed), each equipped with 3 row coil
and with the possibility to add a 1 row coil for 4 pipe systems.
Among fan coils with asynchronous motors, the CRT series is the one that
offers the best compromise between electrical consumption, performance and
cost. At minimum speed (Eurovent estimates that this is 65% of its operating
time), electrical absorption ranges between 6 and 19W according to size and
the sound pressure levels are between 19 and 23 dB(A). Therefore, it is the
ideal solution for aesthetic systems, in areas with low background noise.
FanCoilUnitwithTangentialFanwithAsynchronousMotor
CarismaCRT
Caris
maCRT
131
14,8
15,5
11,5
12,2
16,2
17,0
12,6
13,4
19,6
20,8
15,3
16,5
24,2
25,7
19,2
20,7
24,9
26,4
20,0
21,5
28,7
30,5
23,6
25,4
13,2
13,9
9,9
10,6
14,4
15,2
10,8
11,6
17,3
18,5
13,5
14,7
21,4
22,9
16,9
18,4
22,1
23,6
17,7
19,2
25,4
27,2
20,8
22,6
0,5
0,2
0,6
0,2
0,9
0,3
1,3
0,4
1,6
0,5
1,7
0,5ROW
S 3
3+1
ROW
SRO
WS
MV
MO-MVB
IV-IO
WEIGHT WITH PACKAGING WEighT WiThouT pACKAging
6702253543743303542182051452604601851054755565
7702254544744304542182051452604601851054755565
9852256696896456692182051452604601851054755565
12002258849048608842182051452604601851054755565
12002258849048608842182051452604601851054755565
141522510991119107510992182051452604601851054755565
ABCDEFGHMNOPRSTU
3
3+1
3
3+1
MODEL
MODEL
MODEL
765321
1 2 3 5 6 7
1 2 3 5 6 7 1 2 3 5 6 7
P
R
S
321
T
H
B
230
Ø 15 ext.
Ø 1/2" F
WATER OUTLET
WATER
INLET
Ø 1/2" F
M
37
O
N
T
Ø 15 ext.
BH
230
WATER
INLETWATER
OUTLET
Ø 15 ext.
M
37
O
N
U
GH
230
Ø 1/2" F
WATER
INLETWATER
OUTLET
P
R
S
321
U
H
G
230
Ø 15 ext.
Ø 1/2" F
WATER OUTLET
WATER
INLET
3 row coil 3 row coilHeating
additional coil(1 row)
Heatingadditional coil
(1 row)
Coilconnections
MVandMO-MVBmodel IV-IOmodel
Dimensions, Weight, Water content
Weight(kg)
Watercontent(litres)
Caris
maCRT
Dimension(mm)
60 60
158 158
7144
125
133
C
100
A
530
630
A
B
170
100
7144
125
133
158 158C
60 60
A
530
A
B
170
G
H
Ø 15 ext.
230
7144
125
133
F10
511
100
12
D 2922 22
88
12
153
1711
9 *
D
E*12 12
Feet(optional)
Auxiliarycondensatetray(optional)
*Supplyframedimension=Ex119mm
Dimensions, Weight, Water content
Coilconnectionsontheleft
MVmodel
MO-MVBmodel
IV-IOmodel
133
90
0,49
0,38
0,60
0,6
0,6
6
27
18
110
0,57
0,46
0,69
0,8
0,8
8
31
22
135
0,67
0,55
0,80
1,1
1,0
11
36
27
165
0,76
0,63
0,91
1,4
1,3
14
41
32
190
0,84
0,71
1,01
1,6
1,5
17
44
35
225
0,95
0,81
1,13
2,0
1,9
23
47
38
215
1,41
1,04
1,64
3,0
1,1
12
26
17
275
1,72
1,28
1,95
4,3
1,5
15
31
22
345
2,09
1,57
2,31
6,1
2,0
21
37
28
420
2,44
1,85
2,65
8,0
2,5
27
41
32
475
2,67
2,05
2,87
9,4
2,9
33
43
34
580
3,11
2,41
3,30
12,2
3,7
46
48
39
285
1,77
1,32
2,00
4,6
1,5
15
31
22
345
2,09
1,57
2,31
6,1
2,0
20
36
27
440
2,53
1,93
2,74
8,5
2,7
28
43
34
520
2,87
2,21
3,07
10,6
3,2
35
47
38
600
3,19
2,48
3,39
12,8
3,9
44
50
41
735
3,70
2,93
3,90
16,6
4,9
60
54
45
345
2,21
1,64
2,52
7,8
2,7
19
32
23
420
2,59
1,93
2,89
10,3
3,4
24
36
27
540
3,17
2,40
3,46
14,8
4,7
34
43
34
640
3,62
2,76
3,90
18,6
5,8
43
47
38
735
4,04
3,11
4,31
22,6
6,9
53
50
41
895
4,63
3,61
4,91
28,7
8,7
72
55
46
115
0,68
0,52
0,82
1,4
1,3
7
26
17
140
0,80
0,62
0,95
1,9
1,6
9
31
22
170
0,92
0,71
1,07
2,4
2,0
12
35
26
210
1,08
0,86
1,25
3,3
2,6
16
40
31
240
1,20
0,96
1,38
3,9
3,1
19
43
34
290
1,36
1,11
1,56
4,9
3,9
25
47
38
165
1,05
0,78
1,25
4,5
3,4
8
28
19
200
1,25
0,93
1,45
6,1
4,4
10
31
22
255
1,54
1,16
1,74
8,8
6,1
15
36
27
300
1,73
1,32
1,93
10,8
7,3
18
40
31
345
1,94
1,49
2,14
13,2
8,8
23
44
35
415
2,22
1,73
2,43
16,8
11,0
31
48
39
1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6 1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6 1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6
1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6 1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6 1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6Speed
Speed
Air flow
Cooling total emission (E)
Cooling sensible emission (E)
Heating (E)
Dp Cooling (E)
Dp Heating (E)
Fan (E)
Sound power (E)
Sound pressure (*)
Air flow
Cooling total emission (E)
Cooling sensible emission (E)
Heating (E)
Dp Cooling (E)
Dp Heating (E)
Fan (E)
Sound power (E)
Sound pressure (*)
m3/h
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
m3/h
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
MODEL
MODEL
CRT 13+1
CRT 53+1
CRT 23+1
CRT 63+1
CRT 33+1
CRT 73+1
(E) = Eurovent certified performance. MIN-MED-MAX = Standard connected speeds.(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
95
0,51
0,40
0,68
1,17
0,7
0,5
6
27
18
115
0,59
0,48
0,80
1,39
0,9
0,7
8
31
22
140
0,69
0,56
0,94
1,64
1,2
0,9
11
36
27
175
0,79
0,66
1,11
1,94
1,5
1,2
14
41
32
200
0,87
0,74
1,24
2,17
1,8
1,5
17
44
35
240
0,99
0,86
1,44
2,52
2,2
1,9
23
47
38
225
1,46
1,08
1,77
2,97
3,3
2,7
12
26
17
285
1,77
1,32
2,17
3,65
4,6
3,7
15
31
22
360
2,17
1,64
2,69
4,54
6,5
5,4
22
37
28
440
2,53
1,93
3,16
5,34
8,5
7,0
27
41
32
495
2,76
2,12
3,47
5,87
9,9
8,1
33
43
34
610
3,23
2,52
4,13
6,98
13,1
11,0
46
48
39
305
1,88
1,41
2,31
3,89
5,1
4,1
15
31
22
370
2,19
1,66
2,73
4,59
6,6
5,5
20
36
27
475
2,67
2,05
3,34
5,66
9,4
7,6
28
43
34
560
3,02
2,34
3,83
6,49
11,6
9,7
35
47
38
635
3,33
2,61
4,26
7,23
13,8
11,4
44
50
41
780
3,87
3,07
5,03
8,55
18,0
15,2
60
54
45
360
2,29
1,70
2,78
4,66
8,5
7,0
19
32
23
445
2,72
2,04
3,33
5,62
11,5
9,1
24
36
27
570
3,32
2,52
4,10
6,91
16,6
13,1
34
43
34
680
3,77
2,89
4,71
7,96
20,9
16,2
43
47
38
780
4,18
3,23
5,27
8,91
25,1
19,8
53
50
41
945
4,82
3,78
6,16
10,44
31,7
25,2
72
55
46
125
0,73
0,56
0,94
1,59
1,6
1,3
7
26
17
150
0,85
0,66
1,11
1,88
2,1
1,8
9
31
22
180
0,96
0,75
1,27
2,16
2,6
2,2
12
35
26
225
1,14
0,91
1,53
2,61
3,6
3,0
16
40
31
250
1,24
0,99
1,66
2,86
4,1
3,3
19
43
34
305
1,41
1,15
1,93
3,33
5,2
4,3
25
47
38
170
1,09
0,81
1,32
2,21
5,0
4,1
8
28
19
205
1,29
0,96
1,57
2,64
6,7
5,3
10
31
22
275
1,63
1,23
2,02
3,41
10,1
8,3
15
36
27
315
1,83
1,39
2,27
3,83
12,3
10,2
18
40
31
370
2,04
1,56
2,55
4,31
15,2
12,5
23
44
35
440
2,36
1,83
2,99
5,07
20,0
15,6
31
48
39
1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6 1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6 1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6
1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6 1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6 1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6Speed
Speed
Air flow
Cooling total emission (E)
Cooling sensible emission (E)
Heating (E)
Heating - Water 70-60°C
Dp Cooling (E)
Dp Heating (E)
Fan (E)
Sound power (E)
Sound pressure (*)
Air flow
Cooling total emission (E)
Cooling sensible emission (E)
Heating (E)
Heating - Water 70-60°C
Dp Cooling (E)
Dp Heating (E)
Fan (E)
Sound power (E)
Sound pressure (*)
m3/h
kW
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
m3/h
kW
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
MODEL
MODEL
CRT 13
CRT 53
CRT 23
CRT 63
CRT 33
CRT 73
(E) = Eurovent certified performance. MIN-MED-MAX = Standard connected speeds.(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
Certificationwww.eurovent-certification.com
www.certiflash.com
Certificationwww.eurovent-certification.com
www.certiflash.com
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
2pipeunits.The following standard rating conditions are used:
Unitswith3rowcoil Unitswith1rowadditionalcoil
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CWater temperature: +70°C E.W.T. +60°C L.W.T.
4pipeunits.The following standard rating conditions are used:
Caris
maCRT
135
Built-inelectronic
control
Wallelectronic control
TMO – T FREE
Caris
maCRT
StandardMV-MVBmodels
StandardMV,MO-MVBandIV-IOmodels
FreeSabianawirelesscontrolsystem
NOTES: for more details about the Controls, see Page 225. for full list of main Accessories, see Page 235.
Hardware/software supervisory system (to be used with MB board only)
Router for Sabianet
Relay output board for Sabianet
SabianetROUTER-S
SIOS
N.B.: if the electric heater is mounted, use the "IAQ" controls.
N.B.: if the electric heater is mounted, use the "IAQ" controls.
3 speed control
3 speed control with electronic thermostat and manual summer/winter switch
3 speed control with electronic thermostat and centralized summer/winter switch
Automatic 3 speed control with electronic thermostat and summer/winter switch
CBCB-TCB-C
CB-AU
Electronic controls included
3 speed control
3 speed control with electronic thermostat and manual summer/winter switch
3 speed control with electronic thermostat and summer/winter switch
Automatic speed control with electronic thermostat and summer/winter switch
Automatic speed control with electronic thermostat, summer/winter switch and liquid crystal display
Automatic speed control with electronic thermostat to be mounted in the DIN 503 box (for units with valves)
Electromechanical thermostat with summer/winter switch (only for 2 pipe units)
MO-3VCR-T
TMO-TTMO-T-AU
TMO-DI
TMO-503-SV2T2T
Wall electronic controls
Remote control to be used with electronic boards described at Page 228Free-Com
MB electronic board fitted on the unit
MB electronic board supplied with separate packaging
Wall control (to be used with MB board only)
RT03 infra-red remote control with fitted receiver, for MV/MO-MVB models (to be used with MB board only)
Control fitted on the unit, for MV/MVB models with left connections (available with right connections, to be used with MB board only)
Control supplied with separate packaging, for MV/MVB models with left connections (available with right connections, to be used with MB board only)
RT03 infra-red remote control with receiver supplied with separate packaging (to be used with MB board only)
RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Receiver for RT03 infra-red remote control fitted on the unit, for MV/MO-MVB models (to be used with MB board only)
Receiver for RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Multifunction control (to be used with MB board only)
MB-MMB-ST-MB
RM-RT03
T-MB-M
T-MB-S
RS-RT03RT03RM
RSPSM-DI
Electronic controls for MB boards
Sabianetmanagementsystemforanetworkoffancoils
137
Technicalcharacteristicsofthemaincomponents:ForthetechnicalcharacteristicsofthevariouscomponentsrefertoCarismaCRCFanCoilUnit,exceptforElectronicmotor:
TheECMrange makes use of the excellent experience
gained with the SkyStar Cassette fan coils with inverter board,
first in the world in production since 2009, and which have had great success
on all markets.
The innovative brushless and sensorless type
synchronous electronic motor with permanent magnets, is controlled
by an inverter board designed and developed in Italy.
The board is mounted on the unit, closed to the motor, without the need
to be cooled down by the air flow.
The air flow rate can be varied incontinuous by means of a 1-10 V signal
generated by Sabiana controls or by independent control systems.
The continuous air flow control improves the acoustic comfort and allows
a more punctual reply to the variation of the thermal loads and a greater stability
of the requested ambient temperature.
The extreme efficiency, also at low speed, makes possible a great reduction
in electric consumption (50% less in comparison to CRT AC motor)
with absorption values under normal operating conditions
that donotexceed8Watt. The excellent values of the CRT range in terms of
sound levels have been maintained inallworkingconditions,without any resonance phenomenon
at any frequency.
The full compliance with
the Electromagnetic Compatibility
Directive and with the other strict
Standards in force is certified by
an independent institutee.
three phase permanent magnet brushless electronic
motor that is controlled with current reconstructed according to a BLAC sinusoidal wave.
The inverter board that controls the motor operation
is powered by 230 Volt, single-phase and, with a switchingsystem, it generates
a three-phase frequency modulated, wave form power supply.
The electric power supply required for the machine
is therefore single-phase with voltage of 230-240V and frequency of 50-60Hz.
Range includes 5airflowrates (from 95 to 900 m3/h) and
5models (for wall and ceiling installation, with casing and concealed),
each equipped with 3 row coil and with the possibility
to add a 1 row coil for 4 pipe systems.
With electrical consumption less than 8 W on the entire range at
the lowest speed, it can be considered to bethebestfancoilonthemarket in electrical consumption. Therefore, it is particularly
suited whenever there are low environmental thermal requirements
and the focus is on consumption and acoustic comfort.
FanCoilUnitwithTangentialFanwithECBrushlessElectronicMotorandInverterBoard
CarismaCRT-ECM
Caris
maCRT-ECM
139
14,8
15,5
11,5
12,2
16,2
17,0
12,6
13,4
19,6
20,8
15,3
16,5
24,2
25,7
19,2
20,7
28,7
30,5
23,6
25,4
13,2
13,9
9,9
10,6
14,4
15,2
10,8
11,6
17,3
18,5
13,5
14,7
21,4
22,9
16,9
18,4
25,4
27,2
20,8
22,6
0,5
0,2
0,6
0,2
0,9
0,3
1,3
0,4
1,7
0,5ROW
S 3
3+1
ROW
SRO
WS
MV
MO-MVB
IV-IO
WEIGHT WITH PACKAGING WEighT WiThouT pACKAging
6702253543743303542182051452604601851054755565
7702254544744304542182051452604601851054755565
9852256696896456692182051452604601851054755565
12002258849048608842182051452604601851054755565
141522510991119107510992182051452604601851054755565
ABCDEFGHMNOPRSTU
3
3+1
3
3+1
MODEL
MODEL
MODEL
75321
1 2 3 5 7
1 2 3 5 7 1 2 3 5 7
P
R
S
321
T
H
B
230
Ø 15 ext.
Ø 1/2" F
WATER OUTLET
WATER
INLET
Ø 1/2" F
M
37
O
N
T
Ø 15 ext.
BH
230
WATER
INLETWATER
OUTLET
Ø 15 ext.
M
37
O
N
U
GH
230
Ø 1/2" F
WATER
INLETWATER
OUTLET
P
R
S
321
U
H
G
230
Ø 15 ext.
Ø 1/2" F
WATER OUTLET
WATER
INLET
3 row coil 3 row coilHeating
additional coil(1 row)
Heatingadditional coil
(1 row)
Coilconnections
MVandMO-MVBmodel IV-IOmodel
Dimensions, Weight, Water content
Weight(kg)
Watercontent(litres)
Caris
maCRT-ECM
60 60
158 158
7144
125
133
C
100
A
530
630
A
B
170
100
7144
125
133
158 158C
60 60
A
530
A
B
170
G
H
Ø 15 ext.
230
153
1711
9 *
D
E*12 12
7144
125
133
F10
511
100
12
D 2922 22
130
12
Feet(optional)
Auxiliarycondensatetray(optional)
*Supplyframedimension=Ex119mm
Dimensions, Weight, Water content
Coilconnectionsontheleft
MVmodel
MO-MVBmodel
IV-IOmodel
Dimension(mm)
141
MODEL CRT–ECM13
CRT–ECM23
CRT–ECM33
CRT–ECM53
CRT–ECM73
B
B
B
B
A
A
A
A
A
A
105
0,55
0,44
0,80
1,39
0,8
0,7
4,0
29
20
165
0,76
0,63
1,10
1,95
1,4
1,1
6,0
39
30
240
0,99
0,86
1,48
2,63
2,2
1,8
10,0
48
39
150
0,85
0,66
1,17
2,01
2,1
1,7
4,5
33
24
215
1,11
0,88
1,52
2,63
3,4
2,7
6,5
43
34
305
1,41
1,15
1,96
3,41
5,2
4,2
11,5
49
40
220
1,37
1,02
1,79
3,05
7,4
6,2
5,0
33
24
325
1,88
1,43
2,45
4,17
12,9
10,4
8,5
42
33
450
2,38
1,85
3,12
5,32
19,7
16,0
16,0
49
40
295
1,83
1,37
2,39
4,07
4,8
3,9
6,0
35
26
460
2,62
2,01
3,45
5,88
9,1
7,4
11,5
46
37
675
3,49
2,74
4,63
7,92
15,0
12,1
26,0
53
44
400
2,48
1,85
3,14
5,31
9,6
7,7
7,0
37
28
630
3,57
2,73
4,57
7,74
18,2
15,0
15,0
48
39
900
4,67
3,65
6,06
10,31
29,1
24,0
38,0
56
47
1 (E)
MIN
5 (E)
MED
10 (E)
MAX
1 (E)
MIN
5 (E)
MED
10 (E)
MAX
1 (E)
MIN
5 (E)
MED
10 (E)
MAX
1 (E)
MIN
5 (E)
MED
10 (E)
MAX
1 (E)
MIN
5 (E)
MED
10 (E)
MAX
Inverter Power (V)
Speed
Air flow
Cooling total emission (E)
Cooling sensible emission (E)
Heating (E)
Heating - Water 70-60°C
Dp Cooling (E)
Dp Heating (E)
Fan (E)
Sound power (E)
Sound pressure (*)
Energy classification FCEER (**)
Energy classification FCCOP (***)
m3/h
kW
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
(E)
(E)
B
C
B
B
A
A
A
A
A
B
95
0,51
0,40
0,62
0,7
0,7
4,0
29
20
150
0,72
0,60
0,85
1,3
1,1
6,0
39
30
225
0,95
0,81
1,09
2,0
1,8
10,0
48
39
135
0,78
0,60
0,98
1,8
1,7
4,5
33
24
195
1,02
0,81
1,23
2,9
2,5
6,5
43
34
285
1,34
1,09
1,57
4,8
3,9
11,5
49
40
200
1,25
0,93
1,54
6,1
4,9
5,0
33
24
295
1,71
1,30
2,00
10,6
7,8
8,5
42
33
415
2,22
1,73
2,51
16,8
11,6
16,0
49
40
270
1,69
1,26
2,05
4,2
1,6
6,0
35
26
420
2,44
1,85
2,76
8,0
2,7
11,5
46
37
640
3,35
2,62
3,67
14,0
4,4
26,0
53
44
355
2,26
1,68
2,67
8,2
3,0
7,0
37
28
565
3,29
2,50
3,68
15,8
5,2
15,0
48
39
820
4,35
3,37
4,72
25,7
8,1
38,0
56
47
1 (E)
MIN
5 (E)
MED
10 (E)
MAX
1 (E)
MIN
5 (E)
MED
10 (E)
MAX
1 (E)
MIN
5 (E)
MED
10 (E)
MAX
1 (E)
MIN
5 (E)
MED
10 (E)
MAX
1 (E)
MIN
5 (E)
MED
10 (E)
MAX
Inverter Power (V)
Speed
Air flow
Cooling total emission (E)
Cooling sensible emission (E)
Heating (E)
Dp Cooling (E)
Dp Heating (E)
Fan (E)
Sound power (E)
Sound pressure (*)
Energy classification FCEER (**)
Energy classification FCCOP (***)
m3/h
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
MODEL CRT–ECM13+1
CRT–ECM23+1
CRT–ECM33+1
CRT–ECM53+1
CRT–ECM73+1
(E) = Eurovent certified performance. (*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec. (**) FCEER = Energy classification in Cooling. (***) FCCOP= Energy classification in Heating.
(E)
(E)
Certificationwww.eurovent-certification.com
www.certiflash.com
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
2pipeunits.The following standard rating conditions are used:
Unitswith3rowcoil
Unitswith1rowadditionalcoil
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CWater temperature: +70°C E.W.T. +60°C L.W.T.
4pipeunits.The following standard rating conditions are used:
Caris
maCRT-ECM
MV-MVBmodels
MV,MO-MVBandIV-IOmodels
NOTES: for more details about the Controls, see Page 225. for full list of main Accessories, see Page 235.
Continuous fan speed control with electronic thermostat and summer/winter switchCB-T-ECM
Electronic controls included
Continuous fan speed control with electronic thermostat and summer/winter switch
Continuous fan speed control with electronic thermostat and summer/winter switch
Power unit for CR-T-ECM and CR-DI-ECM remote control, fitted on the unit
Power unit for CR-T-ECM and CR-DI-ECM remote control, not fitted on the unit
CR-T-ECMCR-DI-ECMUPM-ECMUPS-ECM
Wall electronic controls
Electronic controls for MB boards
Sabianet (to be used with MB board only)
Router for Sabianet
Relay output board for Sabianet
SabianetROUTER-S
SIOS
Sabianetmanagementsystemforanetworkoffancoils
MB electronic board fitted on the unit
MB electronic board supplied with separate packaging
Wall control (to be used with MB board only)
RT03 infra-red remote control with fitted receiver, for MV/MO-MVB models (to be used with MB board only)
Control fitted on the unit, for MV/MVB models with left connections (available with right connections, to be used with MB board only)
Control supplied with separate packaging, for MV/MVB models with left connections (available with right connections, to be used with MB board only)
RT03 infra-red remote control with receiver supplied with separate packaging (to be used with MB board only)
RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Receiver for RT03 infra-red remote control fitted on the unit, for MV/MO-MVB models (to be used with MB board only)
Receiver for RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Multifunction control (to be used with MB board only)
MB-ECM-MMB-ECM-S
T-MB
RM-RT03
T-MB-M
T-MB-S
RS-RT03RT03RM
RSPSM-DI
143
Technicalcharacteristicsofthemaincomponents:Outercasing: made with strong synthetic
lateral corners and from galvanized and pre-
painted front steel panel. The plastic top grid
has fixed louvres and is reversible in order to
distribute the air in two different directions.
Standardcolours:
• Lateral corners and top grid:
PantoneCoolGrey1C(lightgrey)
• Front panel: RAL9003(white)
• Other colours on request.
Innercasing: made from galvanized steel
insulated with polyolefin (PO) foam (class M1).
Filter: polypropylene cellular fabric regenerating filter. The filter frame of galvanized steel is
inserted into special plastic sliding guides fastened to the internal structure for easy insertion
and removal of the filter. Filter presence is highlighted by a plastic front cover featuring the
same colour as the top grid.
Fanassembly: the tangential fan assembly is composed of two fan shrouds: an external
one in ABS and an internal one of perforated, shaped steel. The fan has an external diameter
of 120mm and is the length of the coil. The fins are concave and are positioned in a spiral
shape along the whole length of the fan.
Electricmotor: the motor is wired for single phase and has six speeds, three of which
are connected, with capacitor. The motor is fitted on sealed for life bearings and is secured
on anti-vibration and self-lubricating mountings. Internal thermal protection with automatic
reset, protection IP 20, class B.
Coil: it is manufactured from drawn copper tube
and the aluminium fins are mechanically bonded
onto the tube by an expansion process. The coil
has two 1/2inch BSP internal connections and 1/8
inch BSP air vent and drain. The coil is not suitable
for use in corrosive atmosphere or in environments
where aluminium may be subject to corrosion.
Flowandreturnpipeconnectionsaresituated
atthesameendontheleftsidelookingatthe
unit.Onrequestwecandelivertheunitwiththe
connectionsontherightendside:thismustbe
specifiedontheorderasthisoperationcannotbecarriedoutonsiteduringinstallation.
Condensatecollectiontray: made from plastic fitted on the inner casing. The outside
diameter of the condensate discharge pipe is 15 mm.
Range includes 4airflowrates (from 110 to 500 m3/h)
and 1model, vertical for wall installation,
equipped with 2 row coil.
TheCRR series was created to offer
a residential fan coil with a sophisticated design and
low depth (183mm)and a specially silent tangential fan assembly.
FanCoilUnitwithTangentialFanwithAsynchronousMotor
CarismaCRR
Caris
maCRR
145
13,8 14,7 17,6 22,2 12,6 13,2 15,6 19,7
A
530
630
A 158 158
7144
125
133
C
100
100
143
45
475
273
225
163
183
Ø 1/2" F
Ø 1
5 ex
t.
100
(min
.)
60 60
WATER OUTLET
WATER INLET
1100,630,500,801,406,04,0203425
1500,780,601,001,789,05,5223728
1800,870,701,202,0311,07,0284233
1600,950,711,131,9111,59,5203425
2001,100,861,322,2515,512,5223930
2501,301,011,602,6920,016,5274536
2301,311,081,803,024,44,0223425
2901,591,312,203,806,35,0263930
3601,871,532,604,577,87,0314536
3202,001,402,504,2211,010,5253425
4002,401,713,005,0814,514,1304031
5002,802,053,606,1220,018,8364637
1 (E)
MIN
2 (E)
MED
3 (E)
MAX
1 (E)
MIN
2 (E)
MED
3 (E)
MAX
1 (E)
MIN
2 (E)
MED
3 (E)
MAX
1 (E)
MIN
2 (E)
MED
3 (E)
MAX
(E) = Eurovent certified performance. MIN-MED-MAX = Standard connected speeds.(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
MODEL CRR 1 CRR 2 CRR 3 CRR 4
Speed
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*)
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
Certificazioniwww.eurovent-certification.com
www.certiflash.com
0,4 0,5 0,8 1,1
WEIGHT WITH PACKAGING WEighT WiThouT pACKAging
670
354
770
454
985
669
1200
884
A
C
MODEL
MODEL
MODEL
41 2 3
1 2 3 4
1 2 3 4 1 2 3 4
Feet(optional)
NOTES: for more details about the Controls, see Page 225. for full list of main Accessories, see Page 235.
Wall electronic controls
MVmodel
Dimensions, Weight, Water content
Weight(kg)
Watercontent(litres)
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
2pipeunits.The following standard rating conditions are used:
Unitswith2rowcoil
3 speed control
3 speed control with electronic thermostat and manual summer/winter switch
3 speed control with electronic thermostat and centralized summer/winter switch
Automatic 3 speed control with electronic thermostat and summer/winter switch
CBCB-TCB-C
CB-AU
Electronic controls included
Remote control to be used with electronic boards described at Page 228Free-ComFreeSabianawirelesscontrolsystem
Caris
maCRR
Dimension(mm)
147
Range includes 5airflowrates (from 145 to 925 m3/h)
each equipped with 4 row coil and with the possibility
to add a 1 row coil for 4 pipe systems.
It includes some models from the CRC series
but with aparticularlysturdycasing, suited for installation
in public places where there is a high risk
of damage and improper use of the fan coil.
Caris
maCRCMVIversion
Technicalcharacteristicsofthemaincomponents:Casing: in galvanised steel plate, pre-painted in RAL 9002 (light grey),
thickness 1.2 mm with built-in safety closures and keys for opening the front panel.
Outputgrills: in grey-finished extruded aluminium.
Innercasing: made from galvanized steel insulated with polyolefin (PO) foam (class M1).
Filter: polypropylene cellular fabric regenerating filter.
Fanassembly: the fans have aluminium or plastic blades directly keyed on the motor
with double aspiration and they are dynamically and statically balanced during manufacture
in order to have an extremely quiet operation.
Electricmotor: the motor is wired for single phase and has six speeds,
three of which are connected, with capacitor. The motor is fitted on sealed for life bearings
and is secured on anti-vibration and self-lubricating mountings.
Internal thermal protection with automatic reset, protection IP 20, class B.
Coil: it is manufactured from drawn copper tube and the aluminium fins are mechanically
bonded onto the tube by an expansion process. The coil has two 1/2inch BSP
internal connections and 1/8 inch BSP air vent and drain. The coil is not suitable for use
in corrosive atmosphere or in environments where aluminium may be subject to corrosion.
Condensatecollectiontray: made from plastic fitted
on the inner casing; the tray is insulated with polyolefin (PO) foam (class M1).
The outside diameter of the condensate discharge pipe is 15 mm.
FanCoilUnitwithCentrifugalFanwithAsynchronousMotor
CarismaCRCMVIversion
149
25,0
25,8
32,5
33,7
39,1
40,6
40,0
41,5
46,6
48,4
23,0
23,8
29,5
30,7
36,1
37,6
37,0
38,5
42,6
44,4
C
258
44
73
145
37
260
460 53
0
A
105 105
110
245
B
105
185
475
321
WATER OUTLET
WATER INTLET
4453,032,223,555,939,57,7443829
2,893,4
5353,562,624,207,0212,510,3544233
3,294,3
6304,083,034,868,1215,913,3664738
3,685,2
7354,643,475,559,3020,016,9795142
4,096,3
8405,173,896,19
10,3824,220,5925445
4,497,4
9255,584,236,7111,2627,723,71035647
4,798,3
1 2 (E)
MIN
3 4 (E)
MED
5 6 (E)
MAX
2501,791,302,063,447,35,7182617
1,771,2
3152,191,602,534,2310,48,3223122
2,071,6
4202,832,083,305,5116,313,1323728
2,532,3
4953,252,403,816,3720,817,0394132
2,832,8
5453,542,634,176,9724,219,9464334
3,033,2
6504,093,074,838,0731,325,7614839
3,423,9
1 2 (E)
MIN
3 4 (E)
MED
5 (E) 6
MAX
1851,320,951,542,573,42,5142718
1,343,9
2651,831,342,163,626,14,6213324
1,736,0
3352,281,682,724,569,06,9283930
2,068,2
4002,651,973,175,3211,79,0344334
2,3210,1
4853,122,343,766,3315,512,2444738
2,6512,8
5703,562,694,347,3019,615,6575243
2,8814,8
1 2 (E)
MIN
3 (E)
MED
4 5 (E)
MAX
6
1451,010,741,181,984,93,9143021
0,941,7
1701,130,831,342,246,14,9163324
1,042,0
2201,431,071,722,889,27,5224031
1,252,8
2501,591,191,923,2211,09,2264334
1,363,3
2951,811,382,203,6913,911,6324738
1,524,0
3402,041,572,504,1917,214,6405142
1,684,8
1 (E)
MIN
2 3 (E)
MED
4 5 (E)
MAX
6
Dimensions, Weight, Water content
4152,832,073,395,6614,411,0373728
2,503,2
5053,382,494,076,8119,715,2464233
2,874,1
5903,862,864,697,8524,819,5554637
3,194,9
6804,383,275,358,9830,924,7674940
3,545,8
7604,793,605,889,9036,229,3785243
3,816,7
8305,133,876,35
10,6840,933,5885445
4,047,4
1 (E)
MIN
2 3 (E)
MED
4 5 (E)
MAX
6
Speed
Speed
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*) Heating (E) Dp Heat. (E)
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*) Heating (E) Dp Heat. (E)
1 row heating additionalcoil (Water 70/60°C)
1 row heating additionalcoil (Water 70/60°C)
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
kWkPa
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
kWkPa
MODEL
MODEL
CRC 24 MVI
CRC 64 MVI
CRC 44 MVI
CRC 74 MVI
CRC 54 MVI
(E)= Eurovent certified performance. MIN-MED-MAX= Standard connected speeds.(*)= The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
Weight(kg)
Watercontent(litres)
Certification
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
2pipeunits.The following standard rating conditions are used:
www.eurovent-certification.comwww.certiflash.com
Unitswith4rowcoil
Caris
maCRCMVIversion
CRC24
MVI
CRC24
MVI
CRC44
MVI
CRC44
MVI
CRC54
MVI
CRC54
MVI
CRC64
MVI
CRC64
MVI
CRC74
MVI
CRC74
MVI
ROW
S 4
4+1
MODEL
0,8
0,2
1,3
0,3
1,7
0,4
2,2
0,5
2,4
0,5
WEIGHT WITH PACKAGING WEighT WiThouT pACKAging
775487454
990702669
1205917884
1205917884
142011321099
ABC
MODEL CRC 74 MVI
CRC 74 MVI
CRC 24 MVI
CRC 24 MVI
CRC 44 MVI
CRC 44 MVI
CRC 54 MVI
CRC 54 MVI
CRC 64 MVI
CRC 64 MVI
ROW
S 4
4+1
MODEL
PSM-DI multifunction controland
Sabianet management systemfor a network of fan coils
Can be connected only to wall controls for Fan Coil Units with asynchronous motors(infra-red remote control excluded). For the Characteristics, see Page 227.
For the Characteristics, see Page 230.
Wall electronic controls
Available accessories: Plinth PLH
Dimension(mm)
151
Technicalcharacteristicsofthemaincomponents:Casing: made from galvanized steel insulated with polyolefin (PO) foam (class M1).
Filter: polypropylene cellular fabric regenerating filter. The filter frame of galvanized steel is
inserted into special plastic sliding guides fastened to the internal structure for easy insertion
and removal of the filter.
Fanassembly: the fans have aluminium or plastic blades directly keyed on the motor
with double aspiration and they are dynamically and statically balanced during manufacture
in order to have an extremely quiet operation.
Electricmotor: the motor is wired for single phase and has five speeds, with capacitor.
The motor is fitted on sealed for life bearings and is secured on anti-vibration and self-lubricating
mountings. Internal thermal protection with automatic reset, protection IP 20, class B.
Coil: it is manufactured from drawn copper tube and the aluminium fins are mechanically
bonded onto the tube by an expansion process. The coil has two 1/2inch BSP internal
connections and 1/8 inch BSP air vent and drain.
The coil is not suitable for use in corrosive atmosphere or in environments where aluminium
may be subject to corrosion.
Flowandreturnpipeconnectionsaresituatedatthesameendontheleftsidelooking
attheunit.Onrequestwecandelivertheunitwiththeconnectionsontherightendside.
Thisoperationcanalsobeeasilycarriedoutonsiteduringinstallation.
Condensatecollectiontray: made from plastic with an “L”-shaped plastic fitted
on the inner casing; the tray is insulated with polyolefin (PO) foam (class M1). The outside
diameter of the condensate discharge pipe is 15 mm.
HighPressureFanCoilUnitwithAsynchronousMotor
CarismaCRSO
Caris
maCRSO
Range includes 4airflowrates (from 375 to 2220 m3/h)
each equipped with 3 or 4 row coil and
with the possibility to add a 1 or 2 row coil for 4 pipe systems.
It is the perfect range to meet all air-conditioning requirements
of work environments like offices, shops,
restaurants and hotel rooms featuring ducted installations
with available pressure upto80Pa.
All range is compliant with the newERP2013Regulation(EU)No.327/2011 which requires verylowelectricconsumptionratings in relation to performances provided.
153
17,318,519,218,319,5
23,525,025,924,826,3
27,329,130,228,830,6
43,345,6
–45,147,4
19,120,321,020,121,3
26,127,628,527,428,9
30,432,233,331,933,7
47,750,0
–49,551,8
153
1711
9 *
7144
125
133
F10
D
E*12 12
511
D22 22
29
12
G
H
Ø 15 ext.
230
100
12
133
125
4471
153
17
D
12 12
GH
Ø 15 ext.230
119 *
E*
F150 10
Ø 1/2" F
M
37
O
N U
Ø 15ext.
G H
230
WATER
INLET
WATER OUTLET
Ø 1/2" F
P
R
S
321
Ø 15ext.
HG
230
U
WATER OUTLET
WATER
INLET
ROW
S
34
+1+2
ROW
S
WEIGHT WITH PACKAGING WEighT WiThouT pACKAging
68964566921820514526046018510547565
90486088424823517027045021011046595
11191075109924823517027045021011046595
0,91,30,30,6
1,62,20,51,0
1,92,80,61,2
15701526155024823517027045021011046595
3,24,20,9–
DEFGHMNOPRSU
33+13+2
44+1
MODEL
MODEL
MODEL
4
4
1 2 3
1 2 3
1 2 3 4 1 2 3 4
3 or 4 row coils Heating additional coil(1 or 2 rows)
Dimensions, Weight, Water content
VerticalInstallation Coilconnections
Weight(kg)
Watercontent(litres)
Caris
maCRSO
Auxiliarycondensatetray(optional)
*Supplyframedimension=Ex119mm
Auxiliarycondensatetray(optional)
*Supplyframedimension=Ex119mm
HorizontalInstallation
Dimensions, Weight, Water content
Coilconnectionsontheleft
Dimension(mm)
155
2 3 4 2 3 4 2 3 4 1 2 3
240
40
1,58
1,14
1,66
9,0
5,3
40
44
52
35
43
285
50
1,81
1,31
1,87
11,5
6,6
46
47
54
38
45
310
60
1,93
1,41
1,98
12,9
7,3
55
50
57
41
48
470
40
2,94
2,17
2,85
11,2
3,8
82
46
52
37
43
525
50
3,19
2,37
3,08
13,0
4,3
90
49
54
40
45
580
60
3,42
2,57
3,28
14,7
4,8
97
51
57
42
48
760
40
4,44
3,36
4,14
11,4
6,2
107
51
57
42
48
885
50
4,92
3,80
4,57
13,7
7,4
121
54
60
45
51
960
60
5,20
4,05
4,82
15,1
8,1
134
57
63
48
54
945
35
5,95
4,39
5,55
8,9
13,5
140
52
59
43
50
1155
50
6,87
5,16
6,33
11,5
17,2
148
56
62
47
53
1285
60
7,40
5,62
6,79
13,1
19,5
158
58
64
49
55
9066363 9069222 9066368 9069224
2 3 4 2 3 4 2 3 4 1 2 3
240
40
1,74
1,23
2,06
5,4
4,2
40
44
52
35
43
285
50
2,01
1,43
2,41
7,0
5,6
46
47
54
38
45
310
60
2,15
1,54
2,60
7,9
6,4
55
50
57
41
48
470
40
3,27
2,32
3,90
18,1
14,3
82
46
52
37
43
525
50
3,57
2,55
4,30
21,2
17,1
90
49
54
40
45
580
60
3,85
2,77
4,69
24,3
20,1
97
51
57
42
48
760
40
4,80
3,52
6,00
9,7
8,0
107
51
57
42
48
885
50
5,36
3,99
6,83
11,9
9,3
121
54
60
45
51
960
60
5,68
4,25
7,31
13,2
10,5
134
57
63
48
54
945
35
6,51
4,68
7,85
11,8
11,0
140
52
59
43
50
1155
50
7,59
5,54
9,39
15,6
13,8
148
56
62
47
53
1285
60
8,22
6,05
10,30
18,0
17,0
158
58
64
49
55
9066363 9069222 9066368 9069224
2 3 4 2 3 4 2 3 4 1 2 3
240
40
1,58
1,14
1,91
9,0
6,9
40
44
52
35
43
285
50
1,81
1,31
2,22
11,5
9,0
46
47
54
38
45
310
60
1,93
1,41
2,39
12,9
10,3
55
50
57
41
48
470
40
2,94
2,17
3,57
10,6
8,3
82
46
52
37
43
525
50
3,19
2,37
3,92
12,3
9,8
90
49
54
40
45
580
60
3,42
2,57
4,25
13,9
11,4
97
51
57
42
48
760
40
4,44
3,36
5,63
11,4
9,0
107
51
57
42
48
885
50
4,92
3,80
6,36
13,7
11,0
121
54
60
45
51
960
60
5,20
4,05
6,79
15,1
11,9
134
57
63
48
54
945
35
5,95
4,39
7,29
8,9
6,8
140
52
59
43
50
1155
50
6,87
5,16
8,62
11,5
9,2
148
56
62
47
53
1285
60
7,40
5,62
9,41
13,1
10,8
158
58
64
49
55
9066363 9069222 9066368 9069224
MODEL CRSO 13+1 CRSO 23+1 CRSO 33+1 CRSO 43+1Speed (E)
Air flow (E)
Available pressure (E)
Cooling total emission (E)
Cooling sensible emission (E)
Heating (E)
Dp Cooling (E)
Dp Heating (E)
Fan (E)
Sound power outlet (E)
Sound power inlet + radiated (E)
Sound pressure outlet (*)
Sound pressure inlet + radiated (*)
Plenum code (E)
m3/h
Pa
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
dB(A)
dB(A)
(E) = Eurovent certified performance.(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
MODEL CRSO 14 CRSO 24 CRSO 34 CRSO 44Speed (E)
Air flow (E)
Available pressure (E)
Cooling total emission (E)
Cooling sensible emission (E)
Heating (E)
Dp Cooling (E)
Dp Heating (E)
Fan (E)
Sound power outlet (E)
Sound power inlet + radiated (E)
Sound pressure outlet (*)
Sound pressure inlet + radiated (*)
Plenum code (E)
m3/h
Pa
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
dB(A)
dB(A)
MODEL CRSO 13 CRSO 23 CRSO 33 CRSO 43Speed (E)
Air flow (E)
Available pressure (E)
Cooling total emission (E)
Cooling sensible emission (E)
Heating (E)
Dp Cooling (E)
Dp Heating (E)
Fan (E)
Sound power outlet (E)
Sound power inlet + radiated (E)
Sound pressure outlet (*)
Sound pressure inlet + radiated (*)
Plenum code (E)
m3/h
Pa
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
dB(A)
dB(A)
(E) = Eurovent certified performance.(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
Certificationwww.eurovent-certification.com
www.certiflash.com
Certificationwww.eurovent-certification.com
www.certiflash.com
Unitswith1rowadditionalcoil
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CWater temperature: +70°C E.W.T. +60°C L.W.T.
4pipeunits.The following standard rating conditions are used:
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
2pipeunits.The following standard rating conditions are used:
Unitswith3and4rowcoil
Caris
maCRSO
157
RT03 infra-red remote control
WallElectronic controls
NOTES: for more details about the Controls, see Page 225. for full list of main Accessories, see Page 235.
FreeSabianawirelesscontrolsystem
Caris
maCRSO
N.B.: if the electric heater is mounted, use the "IAQ" controls.
3 speed control
3 speed control with electronic thermostat and manual summer/winter switch
3 speed control with electronic thermostat and summer/winter switch
Automatic speed control with electronic thermostat and summer/winter switch
Automatic speed control with electronic thermostat, summer/winter switch and liquid crystal display
Automatic speed control with electronic thermostat to be mounted in the DIN 503 box (for units with valves)
Electromechanical thermostat with summer/winter switch (only for 2 pipe units)
MO-3VCR-T
TMO-TTMO-T-AU
TMO-DI
TMO-503-SV2T2T
Wall electronic controlsStandardmodels
Remote control to be used with electronic boards described at Page 229Free-Com
Electronic controls for MB boards
Sabianet (to be used with MB board only)
Router for Sabianet
Relay output board for Sabianet
SabianetROUTER-S
SIOS
MB electronic board fitted on the unit
MB electronic board supplied with separate packaging
Wall control (to be used with MB board only)
RT03 infra-red remote control with receiver supplied with separate packaging (to be used with MB board only)
RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Receiver for RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Multifunction control (to be used with MB board only)
MB-MMB-ST-MB
RS-RT03RT03RS
PSM-DI
Sabianetmanagementsystemforanetworkoffancoils
159
Technicalcharacteristicsofthemaincomponents:ForthetechnicalcharacteristicsofthevariouscomponentsrefertoCarismaCRSFanCoilUnit,exceptforElectronicmotor:
TheECMrange makes use of the excellent experience
gained with the SkyStar Cassette fan coils with inverter
board, first in the world in production since 2009, and
which have had great success on all markets.
The innovative brushless and sensor-less type synchronous electronic motor
with permanent magnets, is controlled by
an inverter board designed and developed
in Italy. The board is mounted on the unit,
closed to the motor, without the need to be
cooled down by the air flow.
The air flow rate can be varied incontinuously by means of a 1-10 V signal generated by
Sabiana controls or by independent control systems. The continuous air flow control improves
the acoustic comfort and allows a quicker response to the variation of the thermal loads and
a greater stability of the requested ambient temperature.
The extreme efficiency, also at low speed, makes it possible to greatly reduce electrical
consumption (50% less in comparison to CRSO AC motor) with absorption values under normal
operating conditions that donotexceed50Watt. The excellent values of the CRS
range in terms of sound levels have been maintained in allworkingconditions,without any resonance phenomenon at any frequency.
The full compliance with
the Electromagnetic Compatibility
Directive and with the other
severe Standards in force is certified
by an independent institute.
three phase permanent magnet brushless electronic
motor that is controlled with current reconstructed according to a BLAC sinusoidal wave.
The inverter board that controls the motor operation
is powered by 230 Volt, single-phase and, with a switchingsystem, it generates
a three-phase frequency modulated, wave form power supply.
The electric power supply required for the machine
is therefore single-phase with voltage of 230-240V and frequency of 50-60Hz.
Caris
maCRS-ECM
Range includes 3airflowrates (from 350 to 1450 m3/h) each equipped
with 3 or 4 row coil and with the possibility to add a 1 or 2 row coil for 4 pipe
systems. In high pressure ducted fan coils, the abilitytocontinuouslyvary the air flow gives great regulation and control flexibility, at the same time
ensuring excellent environmental conditions and extremely low electrical
consumption.
All range is compliant with the newERP2013Regulation(EU)No.327/2011 which requires verylowelectricconsumptionratings in relation to performances provided.
HighPressureFanCoilUnitwithECBrushlessElectronicMotorandInverterBoard
CarismaCRS-ECM
161
17,318,519,218,319,5
23,525,025,924,826,3
27,329,130,228,830,6
19,120,321,020,121,3
26,127,628,527,428,9
30,432,233,331,933,7
153
1711
9 *
7144
125
133
F10
D
E*12 12
511
D22 22
29
12
G
H
Ø 15 ext.
230
100
12
133
125
4471
153
17
D
12 12
GH
Ø 15 ext.230
119 *
E*
F150 10
Ø 1/2" F
M
37
O
N U
Ø 15ext.
G H
230
WATER
INLET
WATER OUTLET
Ø 1/2" F
P
R
S
321
Ø 15ext.
HG
230
U
WATER OUTLET
WATER
INLET
ROW
S
34
+1+2
ROW
S
WEIGHT WITH PACKAGING WEighT WiThouT pACKAging
68964566921820514526046018510547565
90486088424823517027045021011046595
11191075109924823517027045021011046595
0,91,30,30,6
1,62,20,51,0
1,92,80,61,2
DEFGHMNOPRSU
33+13+2
44+1
MODEL
MODEL
MODEL
1 2 3
1 2 3
1 2 3 1 2 3
3 or 4 row coils Heating additional coil(1 or 2 rows)
Dimensions, Weight, Water content
Coilconnections
Weight(kg)
Watercontent(litres)
Caris
maCRS-ECM
VerticalInstallation
Auxiliarycondensatetray(optional)
*Supplyframedimension=Ex119mm
Auxiliarycondensatetray(optional)
*Supplyframedimension=Ex119mm
HorizontalInstallation
Dimensions, Weight, Water content
Coilconnectionsontheleft
Dimension(mm)
163
9066363 9069222 9066368CB
BB
BB
24035
1,551,161,648,95,52445523643
42035
2,662,022,629,03,43045513642
48550
2,982,282,8911,04,14449554046
56065
3,332,573,1913,44,96452584349
28050
1,761,331,8311,16,63248543945
32565
1,981,512,0213,78,04352584349
72035
4,213,273,9710,56,05050564147
82050
4,643,644,3312,47,07153604451
95065
5,164,104,7915,08,310256634754
4 (E)
MIN
6 (E)
MED
8 (E)
MAX
5 (E)
MIN
7 (E)
MED
9 (E)
MAX
4,5 (E)
MIN
6,5 (E)
MED
8,5 (E)
MAX
MODEL CRS–ECM 13+1 CRS–ECM 23+1 CRS–ECM 33+1
Air flow (E)Available pressure (E)Cooling total emission (E)Cooling sensible emission (E)Heating (E)Dp Cooling (E)Dp Heating (E)Fan (E)Sound power outlet (E)Sound power inlet + radiated (E)Sound pressure outlet (*)
Sound pressure inlet + radiated (*)
Plenum code (E)Energy classification FCEER (**) (E)Energy classification FCCOP (***) (E)
Inverter Power (V)
Speed
m3/hPakWkWkWkPakPaW
dB(A)dB(A)dB(A)dB(A)
9066363 9069222 9066368BB
AA
BA
24035
1,691,252,055,44,42445523643
42035
2,912,153,5215,112,43045513642
48550
3,292,443,9918,715,44449554046
56065
3,702,774,5323,019,06452584349
28050
1,931,432,366,85,53248543945
32565
2,191,642,698,57,04352584349
72035
4,493,425,729,17,55050564147
82050
4,983,826,4010,99,07153604451
95065
5,584,327,2113,310,910256634754
9066363 9069222 9066368CB
BA
BA
24035
1,551,161,918,97,32445523643
42035
2,662,023,259,07,43045513642
48550
2,982,283,4611,09,14449554046
56065
3,332,574,1013,411,16452584349
28050
1,761,332,1811,19,03248543945
32565
1,981,512,4813,711,34352584349
72035
4,213,275,3310,58,65050564147
82050
4,643,645,9412,410,27153604451
95065
5,164,106,6815,012,310256634754
4 (E)
MIN
6 (E)
MED
8 (E)
MAX
5 (E)
MIN
7 (E)
MED
9 (E)
MAX
4,5 (E)
MIN
6,5 (E)
MED
8,5 (E)
MAX
MODEL CRS–ECM 13 CRS–ECM 23 CRS–ECM 33
Air flow (E)Available pressure (E)Cooling total emission (E)Cooling sensible emission (E)Heating (E)Dp Cooling (E)Dp Heating (E)Fan (E)Sound power outlet (E)Sound power inlet + radiated (E)Sound pressure outlet (*)
Sound pressure inlet + radiated (*)
Plenum code (E)Energy classification FCEER (**) (E)Energy classification FCCOP (***) (E)
Inverter Power (V)
Speed
m3/hPakWkWkWkPakPaW
dB(A)dB(A)dB(A)dB(A)
4 (E)
MIN
6 (E)
MED
8 (E)
MAX
5 (E)
MIN
7 (E)
MED
9 (E)
MAX
4,5 (E)
MIN
6,5 (E)
MED
8,5 (E)
MAX
MODEL CRS–ECM 14 CRS–ECM 24 CRS–ECM 34
Air flow (E)Available pressure (E)Cooling total emission (E)Cooling sensible emission (E)Heating (E)Dp Cooling (E)Dp Heating (E)Fan (E)Sound power outlet (E)Sound power inlet + radiated (E)Sound pressure outlet (*)
Sound pressure inlet + radiated (*)
Plenum code (E)Energy classification FCEER (**) (E)Energy classification FCCOP (***) (E)
Inverter Power (V)
Speed
m3/hPakWkWkWkPakPaW
dB(A)dB(A)dB(A)dB(A)
(E) = Eurovent certified performance. (*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec. (**) FCEER = Energy classification in Cooling. (***) FCCOP= Energy classification in Heating.
NOTES: for more details about the Controls, see Page 225. for full list of main Accessories, see Page 235.
Certificationwww.eurovent-certification.com
www.certiflash.com
Certificationwww.eurovent-certification.com
www.certiflash.com
Unitswith1rowadditionalcoil
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CWater temperature: +70°C E.W.T. +60°C L.W.T.
4pipeunits.The following standard rating conditions are used:
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
2pipeunits.The following standard rating conditions are used:
Unitswith3and4rowcoil
Caris
maCRS-ECM
Continuous fan speed control with electronic thermostat and summer/winter switch
Continuous fan speed control with electronic thermostat and summer/winter switch
Power unit for CR-T-ECM and CR-DI-ECM remote control, fitted on the unit
Power unit for CR-T-ECM and CR-DI-ECM remote control, not fitted on the unit
CR-T-ECMCR-DI-ECMUPM-ECMUPS-ECM
Wall electronic controls
MB electronic board fitted on the unit
MB electronic board supplied with separate packaging
Wall control (to be used with MB board only)
RT03 infra-red remote control with receiver supplied with sep. pack. (to be used with MB board only)
RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Receiver for RT03 infra-red remote control supplied with sep. pack. (to be used with MB board only)
Multifunction control (to be used with MB board only)
MB-ECM-MMB-ECM-S
T-MBRS-RT03
RT03RS
PSM-DI
Electronic controls for MB boards
Sabianet (to be used with MB board only)
Router for Sabianet
Relay output board for Sabianet
SabianetROUTER-S
SIOS
Sabianetmanagementsystemforanetworkoffancoils
165
Technicalcharacteristicsofthemaincomponents:Casing: made with galvanized steel insulated with polyolefin
(PO) foam (class M1).
Fanassembly: consists of quiet
centrifugal fans in galvanized steel
with two impellers and a directly
driven single phase, four speed
motor, 230V 50Hz, with capacitor,
insulation class B.
Coil: it is manufactured from drawn copper tube and the aluminium fins are mechanically
bonded onto the tube by an expansion process. The Maestro Sabiana range is available with
the combination of either 3 or 4 row coils (sizes 1÷5) with the possibility to add a 1 or 2 row
coil (3+1, 4+1, 3+2, 4+2 versions for 4 pipe systems), and 4 or 6 row coils (sizes 6-7) with the
possibility to add a 2 row coil (4+2, 6+2 versions for 4 pipe systems).
Theconnectionsareonthelefthandsidelookingfromtheairinletoftheunit(seepicture).
Onrequestoronsitetheconnectionscanbemovedtotheotherside.
The coil is not suitable for use in corrosive atmosphere or in environments where aluminium
may be subject to corrosion.
Filter: polypropylene cellular
fabric regenerating filter.
The filter frame of galvanized
steel is inserted into special PVC
sliding guides fastened to the
internal structure for easy insertion
and removal of the filter.
Condensatecollectiontray: made from galvanized steel
insulated with polyolefin (PO) foam (class M1).
TheMaestrohighpressure fan coils are produced in 5 sizes.
Designed and built for concealed installations, they have small dimensions,
are very silent and have a particularly interesting price in relation to their
performance (all sizes, even at the lowest speed, have a residual pressure
head of at least 160Pa).
They are suitable for climate control for small and medium commercial and
sports environments or for large civil environments and integrate perfectly in
regular false ceilings. Each size is equipped with4speed fans, 3 of which
are connected to the terminal board. The base models call for a 4 row coil
but upon request, units with 3 row coils or additional coils (for 4 pipe systems)
with one or two rows can be provided.
A complete set of accessories solves any type of system problem.
MaestroM
TO
All range is compliant with the newERP2013Regulation(EU)No.327/2011 which requires verylowelectricconsumptionratings
in relation to performances provided.
HighPressureFanCoilUnitwithAsynchronousMotor
Maestro
167
FanSide(outlet)
FilterSide(inlet)
Leftconnections(standard)
Rightconnections(onrequest)
FilterSide(inlet)
Filter
Filter
FanSide(outlet)
4R 4R 4R 6R 2R4+2R 4+2R6R 6R6+2R 6+2R
45
46
54
75
85
124
140
127
143
134
152
137
155
130
148
133
151
140
160
143
163
7,6
9,7
11,1
13,8
4,1
5,5
48
49
57
79
89
1133
1133
1133
1445
1445
1535
1535
48
50
58
80
90
51
53
61
84
94
698
698
698
853
853
1100
1100
50
52
60
83
94
53
55
63
87
98
310
310
360
360
435
488
588
47
48
56
78
88
50
51
59
82
92
255
255
305
293
368
421
521
50
51
60
83
94
53
54
63
87
98
991
991
991
1302
1302
1393
1393
51
53
62
86
98
54
56
65
90
102
620
620
620
775
775
1022
1022
1185
1185
1185
1497
1497
1587
1587
54
54
54
58
58
59
59
245
245
295
291
367
416
516
50
50
50
54
54
55
55
249
249
299
295
370
421
521
3/4”
1”
1”
1 1/4”
1 1/4”
1 1/4”
1 1/4”
3/4”
1”
1”
1 1/4”
1 1/4”
1 1/4”
1 1/4”
3/4”
3/4”
3/4”
1”
1”
1”
1”
1,5
1,8
2,4
3,2
4,1
0,9
1,1
1,4
2,0
2,7
2,6
3,7
4,6
6,0
7,1
2,0
2,9
3,5
4,7
5,7
3/4”
3/4”
3/4”
1”
1”
1”
1”
MTO 1MTO 2MTO 3MTO 4MTO 5
MTO 6MTO 7
MTO 1MTO 2MTO 3MTO 4MTO 5MTO 6MTO 7
MODEL
MODEL
WEIGHT WITHOUT PACKAGING (kg) WEIGHT WITH PACKAGING (kg)
DIMENSIONSADDITIOTIONALMAIN
WATER CONTENT (liters)
COIL
A B C D E F G H L M N
3R 3R
mm
3+1R 3+1R
mm
3+2R 3+2R
mm
4R 4R
mm
4+1R 4+1R
mm
4+2R 4+2R
mm mm mm mm mm
3R 4R 1R 2R
mm IN INOUT OUT1 2 3 4
Dimensions, Weight, Water contentCertification
www.eurovent-certification.comwww.certiflash.com
Unitswith4rowcoil
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
2pipeunits.The following standard rating conditions are used:
Unitswithadditionalcoil
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CWater temperature: +70°C E.W.T. +60°C L.W.T.
4pipeunits.The following standard rating conditions are used:
MaestroM
TO
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
9034280 9034290
1 2 3 1 2 3
1860
150
12,89
9,37
19,81
7,3
11,9
565
63
-
54
-
3330
150
19,31
14,77
29,78
15,0
24,9
750
71
-
62
-
4680
150
23,85
18,95
37,13
22,0
37,0
1327
77
-
68
-
3920
150
23,03
17,55
35,50
14,4
23,8
1499
71
-
62
-
5040
150
26,98
21,12
41,88
19,1
32,0
1727
75
-
66
-
6980
150
32,74
26,66
51,31
27,1
46,1
2376
81
-
72
-
1880
150
12,99
9,45
20,86
7,4
3,9
574
63
-
54
-
3385
150
19,51
14,94
33,52
15,3
9,1
778
71
-
62
-
4800
150
24,19
19,28
43,6
22,6
14,7
1304
77
-
68
-
3925
150
23,06
17,57
39,34
14,4
8,5
1518
71
-
62
-
5070
150
27,09
21,22
47,85
19,3
12,1
1758
75
-
66
-
7100
150
33,09
26,99
61,14
27,6
18,8
2460
81
-
72
-
9034280 9034290
1 2 3 1 2 3
770
25
4,21
3,29
3,96
4,9
11,7
115
51
52
42
43
1090
50
5,26
4,31
4,87
7,3
17,0
155
59
60
50
51
1350
75
5,97
5,06
5,47
9,2
21,0
185
64
65
55
56
840
15
5,16
3,83
4,63
6,9
14,5
170
50
51
41
42
1390
50
7,18
5,65
6,28
12,5
25,2
225
62
63
53
54
1775
80
8,30
6,76
7,16
16,3
31,9
275
67
68
58
59
1680
30
8,95
6,93
7,62
15,7
15,9
345
61
62
52
53
2045
50
10,09
8,02
8,47
19,4
19,3
415
65
66
56
57
2390
70
11,04
8,97
9,20
22,9
22,3
460
69
70
60
61
2055
35
11,29
8,65
9,83
13,8
27,6
440
63
64
54
55
2545
50
12,88
10,15
11,07
17,4
34,1
540
68
69
59
60
2960
67
14,08
11,33
12,00
20,5
39,5
615
70
71
61
62
2700
35
14,24
11,11
12,67
12,0
26,0
495
66
67
57
58
3245
50
15,92
12,74
14,00
14,7
31,1
610
70
71
61
62
3800
70
17,48
14,31
15,28
17,4
36,3
750
73
74
64
65
790
25
4,28
3,36
5,80
5,1
4,1
115
51
52
42
43
1125
50
5,36
4,41
7,55
7,6
6,2
154
59
60
50
51
1410
75
6,11
5,22
8,86
9,6
7,9
191
64
65
55
56
840
15
5,16
3,83
6,58
6,9
5,6
170
50
51
41
42
1410
50
7,24
5,71
9,79
12,7
10,3
230
62
63
53
54
1825
80
8,44
6,90
11,78
16,8
13,6
285
67
68
58
59
1710
30
9,06
7,02
12,04
16,0
13,1
350
61
62
52
53
2075
50
10,18
8,10
13,87
19,8
16,2
420
65
66
56
57
2440
70
11,18
9,12
15,54
23,4
19,1
470
69
70
60
61
2070
35
11,33
8,69
14,92
13,9
11,2
445
63
64
54
55
2580
50
12,98
10,25
17,55
17,7
14,5
550
68
69
59
60
3020
67
14,23
11,49
19,64
20,9
17,0
630
70
71
61
62
2740
35
15,04
11,71
19,39
13,3
10,8
500
66
67
57
58
3280
50
16,81
13,42
22,12
16,2
13,2
617
70
71
61
62
3850
70
18,52
15,13
24,79
19,3
15,7
760
73
74
64
65
9034200
9034200
9034200
9034200
9034220
9034220
9034230
9034230
9034240
9034240
MODEL MTO
MODEL MTO
14+1
14
24+1
24
34+1
34
44+1
44 54
64+254+1
64
74+2
74
Speed (E)
Air flow (E)
Available pressure (E)
Cooling total emission (E)
Cooling sensible emission (E)
Heating (E)
Dp Cooling (E)
Dp Heating (E)
Fan (E)
Sound power outlet (E)
Sound power inlet + radiated (E)
Sound pressure outlet (*)
Sound pressure inlet + radiated (*)
Plenum code (E)
Speed (E)
Air flow (E)
Available pressure (E)
Cooling total emission (E)
Cooling sensible emission (E)
Heating (E)
Dp Cooling (E)
Dp Heating (E)
Fan (E)
Sound power outlet (E)
Sound power inlet + radiated (E)
Sound pressure outlet (*)
Sound pressure inlet + radiated (*)
Plenum code (E)
m3/h
Pa
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
dB(A)
dB(A)
m3/h
Pa
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
dB(A)
dB(A)
(E) = Eurovent certified performance. (*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec. (**)= Models not covered by EUROVENT certification program.
169
Wall electronic controls
Electronic controls for MB boards
Modulating valve control board
MaestroM
TO
Electric coil
Consists of electric resistancesand a security thermostat,
which are insidea galvanized steel and insulated
casing.
External auxiliarycondensate collection tray
Intake/supply spigot plenum
Intake/supply spigot plenumwith 3 spigots (Sizes 1 - 2 - 3)
or 4 spigots (Sizes 4 - 5).
G3 synthetic filter
The filteris a washable synthetic fibre,
flame-proofaccording to Class F1 DIN 53438.
Efficiency of ASHRAE 84%,Eurovent EU3.
BEM
BCM
PMM
SFM
Main and auxiliary coilvalve kit
(to be used onlywith QCV modulating valve
control board)
Valvewith 3 points - 24 Volt actuator.
Kit24V
Main and auxiliary coilvalve kit
(to be used onlywith ON/OFF 230 V controls:
QCV-MB, TMO-T and TMO-T-AU)
230 V, ON-OFF valve.
Kit230V
Accessories
Antivibrating connection
Intake/supplyantivibrating connection, made
of two galvanized framesand a PVC flexible connection.
GAV
Accessories
MB version control board (T-MB wall control included)
Multifunction control (to be used with QCV-MB control board only)
QCV-MBPSM-DI
Speed selector with 4 positions: OFF, first speed, second speed, third speedCOM 3 speed control
3 speed control with electronic thermostat and summer/winter switch
Automatic speed control with electronic thermostat and summer/winter switch
Receiving board for centralized control
MO-3VTMO-T
TMO-T-AUSEL-S
Modulating valve control board (ETN 500 wall control, air temperature probe, low temperature cut-out thermostat and Change-Over T2 included)QCV
NOTES: for more details about the Controls, see Page 225.
Sabianet (to be used with QCV-MB control board only)
Router for Sabianet
Relay output board for Sabianet
SabianetROUTER-S
SIOS
Sabianetmanagementsystemforanetworkoffancoils
171
The system has been designed to reduce the indoor recirculation of various types of
pollutants found in the ducting of air-conditioning systems. As a result, it is ideal for various
types of environments, such as schools, hospitals and rest homes (corridors, waiting rooms,
wards), doctors’ surgeries, hotels and anywhere indoor air quality needs to be improved.
There are many reasons why pollutants can be found in ducts. The main one is the lack
of cleaning and maintenance of the ducts, together with other factors such as incorrect
equilibrium and/or pressurisation, the circulation of air between different rooms when the
system is off, the lack of suitable filters or the air being bypassed around the filtering cells
inside the air handling unit, the lack of attention paid when replacing the filters, the presence
of favourable conditions in terms of temperature and humidity for the proliferation of bacterial
organisms, etc.
While pollution in ducts can be reduced through periodical maintenance, in reality this is rarely
done due to the considerable costs, the difficulty in accessing the systems or the impossibility
of shutting down the system for an extended period.
One possible alternative solution that significantly reduces the health risks and drastically
cuts the costs of maintenance on ducts involves the installation of active electrostatic filters
immediately before the air is introduced into the room.
Electronic filters are known to be very effective in trapping particles, fibres, biological
substances, etc., even when these are very small in diameter (less than 1 micron), while only
causing a moderate pressure drop in the passing air, both initially (when the filter is clean)
and over time when there is dirt on the surfaces.
The bactericide action of electronic filters prevents the proliferation of biological substances
(bacteria, mould, yeast, etc.) on the surfaces of the transiting dust, even if these are not
trapped by the filter (other "mechanical" filtering systems may, on the other hand, represent
a support that is favourable to the proliferation of biological substances).
The CrystallFlexSystem is consequently an effective, reliable and simple product.
Furthermore, it has extremely low maintenance costs: it never needs replacing and can be
washed and sanitised using ordinary detergents, without any decline in efficiency or product
life.
1) Air outlet grid
2) Electronic filter lock
3) High voltage cable
4) Ionic field
5) Duct
6) “Crystall”electronic filter
TheCrystallFlexSystem is an innovative
filtering system, designed to be easily installed downstream
from horizontal concealed fan coils.
Created especially for the hotel industry, it can be perfectly added
to different structures such as nursing homes
and retirement homes and, more generally, wherever
a high level of comfort and air quality is needed.
It is made up of 3elements: a) patented electronic plate filter (“Femec” type)
b) electronic control and power board
c) high voltage flexible connection cable
CrystallFlexSystem
ElectronicFilterCrystallFlexSystem
173
The Crystall electronic filter is made up of two main elements.
The first is comprised of an electronic plate filter and is inside
a special bearing structure that is designed and shaped based on
the type of intended application. The structural element, therefore defines
the type of application, allowing its installation downstream of horizontal flush-
mounted fan coils (PM-CRY). The second element is the supply and control equipment
that contains the circuit board and connection terminals.
ActiveplateelectronicfilterFemectype
The filter element is made up of two sections: the first
is comprised of tungsten electrodes and insulating
elements. The second section, meant for
capturing polluting particles, is made of paired
and suitably shaped special aluminium
sheets, making up the collection manifold.
This section can be easily removed for
effortless maintenance. The filter's operating
principle is extremely simple. Pollutants cross
the first section made up of electrodes and
electronically charged by the electrical field
produced (ionization). The particles are then
collected on the filter plates that are in opposite polarity.
Due to the high voltage inside the filter an intense and
disparate electrical field is generated with an avalanche effect called a "corona discharge".
Electronicsboard
This mainly contains the filter circuit board. The equipment is
supplied with 230V and is capable of generating a high voltage
but low intensity current (max 3 mA) needed to produce the
ionizing field. A single unit can supply several terminals based
on the total filter surface used. The equipment is supplied with
a remotable alarm status contact and, locally, with a failure indicator
light.
Connectioncable
It is made up of a special AWG-22 wire with external insulation suitable for high voltage use.
Constructionfeatures:
INLETOF POLLUTED AIR
OUTLETOF CLEAN AIR
PHASE
2
PHASE
1
Air withoutparticles < 1 μm
Electrostatic filter
Collectionsurface
Inductedanode
Polarizedelectrode
Ionic field
1 2 3
45
1 2 3
45
AdvantagesoftheCrystallFlexSystem:
• Installation possible on existing systems
• Low impact on the thermal and aeraulic equilibrium of the system
• Reduced pressure drop even when the filter is dirty
• Significant bactericide action on biological pollutants
• No cost for replacing the filters
(the filters are totally regenerable by simply washing them)
• Very low additional energy costs
• Simple and fast maintenance
• No system downtime
for the maintenance of the filtering units
• Remote power supply
that can power multiple filtering units at the same time
TestsandCertification:
The Crystall system has been the subject of numerous trials and efficiency and effectiveness
tests to assess the functions and performance of the systems in real conditions.
At the Turin Polytechnic Department of Energy, efficiency and load loss tests were performed
using the EN779 international filter classification standards, where applicable.
The University of Ancona carried out over 180 laboratory tests on microbiological substances
(total airborne microbiological load), including bacteria, mould, fungi, etc., which confirmed,
through the statistical analysis of the data taken from the Fischer test, the effectiveness of
the Crystall electronic filter in reducing the bacterial load.
Other tests have been carried out in the SABIANA laboratories on the flow-rate,
pressure drop, electrical safety and instrumental efficiency of the filtration process on micro-
particles by numerically counting the most common particle size categories in various rooms.
The particles monitored had the diameters specified by the WHO (World Health Organization)
and the EPA (Environmental Protection Agency) as being the most harmful to our health
(<2.5 micron PM 2.5), with volumetric counts (number/m3) being performed in a common
living environment, using a laser particle counter (LPC).
1) Duct
2) Air outlet grid
3) Shielded high voltage cable
4) Power supply and control box
5) Air outlet
CrystallFlexSystem
175
Fresh air intake kitFAP
TMO-T-AU-IAQ
MO-3V-IAQ
Installation of bimetallic low temp. cut-out thermostat (TMM)
Installation of electronic low temp. cut-out thermostat (TME)
Room thermostat for chilled water valve (SUMMER) and electric heater (WINTER) control (in winter only the electric heater is working)
Simultaneous thermostatic control of the valves and fan
Room thermostat for 1 valve control (2 pipe installation)
Room thermostat for 2 valve control (4 pipe installation)
Room thermostat for fan control (ON-OFF)
Automatic Summer/Winter switch with neutral zone for 4 pipe installation with 2 valves
Remote centralized Summer/Winter switch or by an automatic change-over fitted on the water pipe
Summer/Winter switch
Manual/Automatic 3 speed selection
Manual 3 speed switch
ON-OFF switch for Crystall electrostatic filter or electric heater
ON-OFF switch
FUNCTIONS IDENTIFICATIONMO-3V-IAQ TMO-T-IAQ TMO-T-AU-IAQ
Wall electronic controls
Accessories
TMO-T-IAQ2
3 - 4
5 - 6
-
7
8 - 9
-
1
-
2
-
3
435
635
835
835
1035
1035
400
600
800
800
1000
1000
218
218
218
248
218
248
454
669
884
884
1099
1099
SUITABLE FOR: DIMENSIONS
Size Size
Carisma CRC - IO Model Carisma CRSO A B C D
mm mm mm mm
PM-CRY-2 PM-CRY-3-4 PM-CRY-5-6 PM-CRY-4S PM-CRY-7 PM-CRY-8-9
MODEL
Dimensions
This type of equipment was specifically created to be able to be inserted
downstream of SabianaCarismaCRC(IOmodel) horizontal concealed fan coils
and SabianaCarismaCRSO ducted fan coils.
By adapting the duct and/or the outlet grid, it can also
be installed downstream of existing fan coils.
The structure is made of galvanised plate and is comprised of:
• an adjustable length of duct work;
• a Femec type electrostatic filter;
• an electronic filter control unit that can be installed
on the side of the duct work or on the side of the fan coil;
• an aluminium outlet grill with a double row of fins.
CrystallFlexSystem
177
In addition to temperature and speed
standard controls,
automatic speed
selection is also available.
More than one unit can
be connected to a single control,
and the unit control panel can be installed
in a remote position that facilitatesthe maintenance operation. All theSkyStar units can be supplied inMBversion. This version allows a wide range of controls, including the infra-red remote control,
which can manage one single unit or several units by using theModbusRTU-RS485communication protocol.
The units can be connected to the most common automatic building management systems.
Innovating and beautiful design, sevendifferentsizes,high control flexibility, easy maintenance: theSkyStarchilledwaterCassette is the result of an extended technical
and design development aimed at achieving the highest level
in terms of performance, silent operation and control possibilities.
The air diffuser has an highly attractive aesthetical appearance, very
innovative, and is also able to offer the best air distribution performance thanks
to in-depth computer studies and laboratory tests. The 4 smaller sizes
are designed to fit into600x600mmfalseceiling standard modules.
The 3 bigger sizes have a dimensionof800x800mmwhich allows the best outcome in terms of quietness
and of price/performance ratio for these high capacity models.
CassetteFanCoilUnitwithAsynchronousMotor
SkyStarSK
SkyStarS
K
179
Fanassembly: the fan assembly,
which is mounted on anti-vibrating
supports, is extremely silent.
The radial fan has been designed
to optimise performance,
using wing profile blades with a shape
that reduces turbulence, increasing
efficiency and reducing noise.
The single air inlet radial fan is
connected to a 6speedelectric motor with singlephase230V/50Hz supply, class B
insulation and integrated Klixon
thermal contact for motor protection.
The units are supplied
with 3 standard speeds connected and it is possible to change them on site if necessary.
Coil: made of copper tubes with bonded aluminium fins for maximum transfer contact.
The coils have 1, 2 or 3 rows for 2 pipe models
and 2+1 rows for 4 pipe models (the heating row is on the inside part of the coil).
For 4 pipe systems two versions are available:
• SK04,SK14,SK24,SK34,SK44,SK54,SK64 supply an higher heating emission,
• SK26,SK36,SK56,SK66 supply an higher cooling emission.
The coil is not suitable for use in corrosive atmosphere or in environments where aluminium
may be subject to corrosion.
Condensatecollectiontray: high density ABS polystyrene foam condensate tray,
shaped in order to optimize the air diffusion, fire retardant rating B1 to DIN 4102.
Airfilter: synthetic washable filter, easily removable.
Condensatepump: float switch centrifugal pump with 650 mm of maximum head,
built into the unit and wired to the control panel on the outside of the casing.
Valveset: two or three way valves for ON/OFF operation, with pipe mounting kit
and thermostatic actuator.
Casing: made from galvanized steel with internal thermal insulation
with polyolefin (PO) foam (class M1) and external anti-condensate lining.
Controlpanel: made of an external metallic box
with control electronic board and easily accessible terminal board.
Airdiffuser: intake grid, frame and
adjustable air distribution louvers on each side, made from ABS.
HTAversionwhite ABS, RAL 9003
HTBversionintake grid, frame and louvers
in a colour of choice
HTCversionintake grid and louversin a colour of choice,plus white ABS frame RAL 9003
MD-600versionmetal diffuser painted in RAL 9003white colour with 600x600 dimensionto perfectly fit into the false ceilingstandard modules without overlapping parts(800x800 model is not available)
HTDversionlouvers in a colour of choice,
while the grid and frameare made from ABS, RAL 9003
Technicalcharacteristicsofthemaincomponents:
SkyStarS
K
181
SK42-44/SK52-54-56/SK62-64-66(Version800x800)
Unit
Unit Diffuser
Diffuser
44
47
36
10 6 1050 400 1000 20039
WEIGHTSPACKED UNIT
kg kg kg kg A B C D
WEIGHTSPACKED UNIT
WEIGHTSUNPACKED UNIT
WEIGHTSUNPACKED UNIT
PACKED UNITDIMENSIONS (mm)
SK 42 SK 44 SK 52 - 54 - 56 SK 62 - 64 - 66
MODEL
Dimensions and Weight
2pipeunits3. Flow, heating/cooling 3/4”
4. Return, heating/cooling 3/4”
4pipeunits1. Flow, heating 1/2”
2. Return, heating 1/2”
3. Flow, cooling 3/4”
4. Return, cooling 3/4”
SK02-04/SK12-14/SK22-24-26/SK32-34-36(Version600x600)
Unit
MD-600metaldiffuser
Diffuser
28
30
22
6 3 790 350 750 15024
WEIGHTSPACKED UNIT
kg kg kg kg A B C D
WEIGHTSPACKED UNIT
WEIGHTSUNPACKED UNIT
WEIGHTSUNPACKED UNIT
PACKED UNITDIMENSIONS (mm)
SK 02 - 12 SK 04 - 14 SK 22 - 24 - 26 SK 32 - 34 - 36
MODEL
Dimensions and Weight
2pipeunits3. Flow, heating/cooling 1/2”
4. Return, heating/cooling 1/2”
4pipeunits1. Flow, heating 1/2”
2. Return, heating 1/2”
3. Flow, cooling 1/2”
4. Return, cooling 1/2”
SkyStarS
K
183
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
3202,091,493594,0
1,981703,6332425
0,111,70,5
5003,062,245267,0
2,712336,0453644
0,201,70,5
7103,932,9567610,53,352889,0534468
0,321,70,5
7104,523,2577710,36,4555511,5342542
0,183,01,4
12806,935,18119222,19,9885825,3483995
0,423,01,4
18208,896,84152934,7
12,70109238,85849
1700,743,01,4
4302,361,754067,2
3,102678,8413232
0,151,40,7
6103,022,2951911,23,9734113,8494057
0,271,40,7
8803,812,9765517,04,9542620,5595090
0,451,40,7
7104,993,538589,0
5,234506,5342542
0,183,61,1
12807,845,73134820,07,7466613,0483995
0,423,61,1
182010,207,68175432,09,8084319,55849
1700,743,61,1
4302,721,974686,0
2,462125,0413232
0,151,70,5
6103,532,626079,0
3,062637,8494057
0,271,70,5
8804,533,4677914,03,7932611,0595090
0,451,70,5
3201,851,343184,6
2,432095,7332425
0,111,40,7
5002,651,984568,8
3,4629810,8453644
0,201,40,7
7103,342,5657413,44,4037816,6534468
0,321,40,7
7104,993,538589,0
5,234506,5342542
0,183,61,1
9706,334,55108914,06,425529,2403163
0,283,61,1
15008,776,49150825,08,5673615,35344
1200,533,61,1
3101,511,152606,0
1,961696,5332425
0,111,00,6
4201,961,5533710,02,5421910,5403132
0,151,00,6
6102,331,9040113,53,0326114,5494057
0,271,00,6
6304,142,967128,8
5,915089,8332433
0,153,01,4
8205,033,6586512,57,1961814,0403148
0,233,01,4
11406,344,69109018,99,1078321,4483977
0,363,01,4
3101,851,343184,6
2,432095,7332425
0,111,40,7
4202,361,714066,9
3,022608,5403132
0,151,40,7
5202,701,984648,8
3,4629810,8453644
0,201,40,7
7104,523,2577710,36,4555511,5342542
0,183,01,4
9705,664,1597415,48,1069717,4403163
0,283,01,4
15007,715,83132626,9
11,0094629,95344
1200,533,01,4
Speed
Speed
Air flowCooling total emission (E)Cooling sensible emission (E)Water flowDp Cooling (E)Heating (E)Water flowDp Heating (E)Sound power Lw (E)Sound pressure Lp (*)
Cooling water contentHeating water contentDimensions
Air flowCooling total emission (E)Cooling sensible emission (E)Water flowDp Cooling (E)Heating (E)Water flowDp Heating (E)Sound power Lw (E)Sound pressure Lp (*)
Cooling water contentHeating water contentDimensions
m3/hkWkWl/hkPakWl/hkPa
dB(A)dB(A)
WAll
mm
m3/hkWkWl/hkPakWl/hkPa
dB(A)dB(A)
WAll
mm
Fan (E)
Fan (E)
575 x 575 x 275
820 x 820 x 303
MODEL
MODEL
SK 04
SK 44
SK 14
SK 54
SK 24
SK 56
SK 26
SK 64
SK 34
SK 66
SK 36
(E) = Eurovent certified performance.(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
3101,271,011,622,802194,54,0332425
0,110,8
4201,631,322,123,662807,06,0403132
0,150,8
6101,981,642,644,5634010,09,0494057
0,270,8
6304,213,035,128,6172410,96,7332433
0,153,0
8204,913,586,03
10,1684514,39,9403148
0,233,0
11406,164,597,7713,14106021,615,1483977
0,363,0
3101,841,352,224,193164,94,1332425
0,111,4
4202,341,752,904,914027,66,3403132
0,151,4
5202,682,043,355,684619,78,2453644
0,201,4
7105,313,465,6110,259139,47,9342542
0,184,0
9706,784,487,3413,43116614,712,4403163
0,284,0
15009,516,4810,7119,76163626,923,053441200,534,0
3202,251,572,564,833874,63,5332425
0,112,1
5003,342,393,936,965749,47,3453644
0,202,1
7104,333,185,239,2574515,111,4534468
0,322,1
7105,313,716,1310,259139,47,9342542
0,184,0
12808,456,0910,3017,26145321,818,6483995
0,424,0
182011,108,2514,0023,68190935,630,658491700,744,0
4302,942,083,436,105067,56,7413232
0,152,1
6103,882,814,638,2566712,411,2494057
0,272,1
8805,023,746,1710,6386319,717,7595090
0,452,1
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3Speed
Speed
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CWater flowDp Cooling (E)Dp Heating (E)Sound power Lw (E)Sound pressure Lp (*)
Water contentDimensions
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CWater flowDp Cooling (E)Dp Heating (E)Sound power Lw (E)Sound pressure Lp (*)
Water contentDimensions
m3/hkWkWkWkWl/hkPakPa
dB(A)dB(A)
WAl
mm
m3/hkWkWkWkWl/hkPakPa
dB(A)dB(A)
WAl
mm
Fan (E)
Fan (E)
575 x 575 x 275
820 x 820 x 303
MODEL
MODEL
SK 02
SK 42
SK 12
SK 52
SK 22
SK 62
SK 32
(E) = Eurovent certified performance.(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
Certificationwww.eurovent-certification.com
www.certiflash.com
Certificationwww.eurovent-certification.com
www.certiflash.com
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
HEATING (winter mode)
Entering air temperature: +20°CWater temperature: +70°C E.W.T. +60°C L.W.T.
2pipeunits.The following standard rating conditions are used: 4pipeunits.The following standard rating conditions are used: SkyStarS
K
185
The SkyStar 2 pipe models are availablewith electric heater that is controlled in place of the heating coil valve.
The electric heater is controlled in place of the hot water valve and not as integration to it.The heater is hermetically sealed and supplied inside the coil pipes
and therefore can be only factory mounted.The electric heaters of the SK 12-22-32 units are for single phase 230V supply.The electric heaters of the SK 42-52-62 units are for three phase 400V supply.
Model SK12-E SK22-E/SK32-E SK42-E/SK52-E/SK62-EEmission 1500Watt 2500Watt 3000Watt
SkyStarS
K
All the SkyStar unitscan be supplied in MB version.
This version allowsa wide range of controls,
including the infra-red remote control,which can manage
one single unit or several unitsby using the Modbus RTU - RS 485
communication protocol.
SK-MB
Unit with remote electric board
On request the Skystar cassettesare available with electric control panel
reachable from belowand with the electric board
that can be placed in a remote position.
The MCT version has been designed for all environments where false ceilingsare not featured or cannot be constructed.
The cover cabinet fits perfectly to the air intake and outlet diffuser, maintainingthe appealing design that defines the SkyStar series.
The water fittings can be turned to point upwards.The MCT series includes 7 models, with an installation height of up to 5 m,
thanks to the highly flexible adjustment of the air distribution louvers.All the technical specifications described on the previous pages remain the same,
while keeping in mind that the MCT series features one coil only(two pipe systems), there is no possibility of fresh air intake,
there is no possibility of additional electric heater.The MCT version features a special casing delivered in separate packaging;
this must only be fitted after having installed the SkyStar unitand completed the water and electrical connections.
MCT
Other available Versions
SK-E
SK42-44/52-54-56/62-64-66
SK42-44/52-54-56/62-64-66
SK42-44/52-54-56/62-64-66
SK42-44/52-54-56/62-64-66
SK02-04/12-14/22-24-26/32-34-36
SK02-04/12-14/22-24-26/32-34-36
SK02-04/12-14/22-24-26/32-34-36
SK02-04/12-14/22-24-26/32-34-36
Accessories
3 way ON-OFF valveswith simplified kit
Valve set, 3 ways, ON-OFF,with thermoelectric actuator.
The set includes connection pipes.
2 way ON-OFF valveswith micrometric lockshield valve
Valve set, 2 ways, ON-OFF,with thermoelectric actuator.
The set includesconnection pipes and holders.
3 way ON-OFF valveswith micrometric lockshield valve
Valve set, 3 ways, ON-OFF,with thermoelectric actuator.
The set includesconnection pipes and holders.
2 way ON-OFF valveswith simplified kit
Valve set, 2 ways, ON-OFF,with thermoelectric actuator.
The set includes connection pipes.
Fresh air kit
This is used to introducefresh air into the environmentdirectly through the diffuser.
PRT
Fresh air connectionCAP
Air distribution connectionCDA
187
SKversion
SK-MBversion
NOTES: for more details about the Controls, see Page 225.
3 speed control
3 speed control with electronic thermostat and manual summer/winter switch
3 speed control with electronic thermostat and summer/winter switch
Automatic speed control with electronic thermostat and summer/winter switch
Automatic speed control with electronic thermostat, summer/winter switch and liquid crystal display
Automatic speed control with electronic thermostat to be mounted in the DIN 503 box (for units with valves)
Electromechanical thermostat with summer/winter switch (only for 2 pipe units)
MO-3VCR-T
TMO-TTMO-T-AU
TMO-DI
TMO-503-SV2T2T
Wall electronic controls
Remote control to be used with electronic boards described at Page 229Free-ComFreeSabianawirelesscontrolsystem
SkyStarS
K
IAQ accessorySkyStar Cassette can be equipped with the innovative
plate type electrostatic filter, Crystall,combining air treatment
and purifying in a single product.
The electronic filter
is patentedandcertified according to
Standard UNI 11254.
Dimensions
SK0/1/2/3(Model600x600)
SK4/5/6(Model800x800)
Multifunction control (to be used with SK-MB version only)PSM-DI
Wall control (to be used with SK-MB version only)
RT03 infra-red remote control supplied with separate packaging (to be used with SK-MB version only)
RT03 infra-red remote control with receiver supplied with separate packaging (to be used with SK-MB version only)
Receiver for RT03 infra-red remote control supplied with separate packaging (to be used with SK-MB version only)
Receiver for RT03 infra-red remote control and MD-600 metal diffuser supplied with separate packaging (to be used with SK-MB version only)
T-MB
RT03
RCS-RT03
RCS
RS
Electronic controls
Sabianet (to be used with SK-MB version only)
Router for Sabianet
Relay output board for Sabianet
SabianetROUTER-S
SIOS
Sabianetmanagementsystemforanetworkoffancoils
189
The SkyStarSK-ECMseries, available in 5models, uses
an innovative brushless synchronous permanent magnet electronic motor
controlled by an inverter board that is directly installed on the unit.
The air flow can be variedcontinuously with a 1-10 V signal
from Sabiana controls or by independent contollers
(programmable controllers with a 1-10 V output). The extreme efficiency,
also at a low speed, makes it possible to greatly reduce in electric
consumption (more than75%less in comparison to a traditional motor)
with absorption values, under normal operating conditions, that are
nogreaterthan10Wattin the entire range.
CassetteFanCoilUnitwithECBrushlessElectronicMotorandInverterBoard
SkyStarSK-ECM
SkyStarS
K-ECM
The brushless motor
is characterised by a
constant synchronous speed,
independently of the applied load,
that depends only on the motor power
supply frequency, which is modulated
by the inverter.
Itconsumeslessbecause: • The motor always works at its point of maximum efficiency.
• In the brushless motor, the rotor’s permanent magnets generate
the magnetising power autonomously.
• The motor always operates at the synchronous speed,
as a result there are no induced currents that reduce efficiency.
Themainadvantagesare: • Large reduction in energy consumption, thanks to an optimal
response to the thermal load of the environment during every moment of the day.
• Operating silence at all rotation speeds.
• Ability to operate at any rotation speed.
All theSkyStarSK-ECM units can be supplied inMBversion.This version allows a wide range of controls, including the infra-red remote control,
which can manage one single unit or several units
by using theModbusRTU-RS485communication protocol.
191
Casing: made from galvanized steel with internal thermal insulation
with polyolefin (PO) foam (class M1) and external anti-condensate lining.
Controlequipment:SK-ECMversion: it consists of the pump control circuit board
and the inverter circuit board.
SK-ECM-MBversion: it consists of the MB board
(that integrates pump control) and the inverter board.
Fanassembly: the fan assembly, which
is mounted on anti-vibrating supports, is extremely silent.
The radial fan has been designed to optimise performance, using wing profile blades
with a shape that reduces turbulence, increasing efficiency and reducing noise.
The fans are connected to a three phase permanent magnet brushless electronic motor
that is controlled with reconstructed current according to a BLAC sinusoidal wave.
The inverter board that controls the motor operation
is powered by 230 Volt, single-phase and, with a switchingsystemg,it generates a three-phase frequency modulated, wave form power supply.
The electric power supply required for the machine is therefore
single-phase with voltage of230-240V and frequency of50-60Hz.
Coil: made of copper tubes with bonded aluminium fins
for maximum transfer contact. The coils have 2 or 3 rows for 2 pipe models and
2+1 rows for 4 pipe models (the heating row is on the inside part of the coil).
For 4 pipe systems two versions
are available: • SK14,SK44 supply an higher heating emission,
• SK26,SK36,SK56 supply an higher cooling emission.
The coil is not suitable
for use in corrosive atmosphere
or in environments where aluminium
may be subject to corrosion.
Condensatecollectiontray:high density ABS polystyrene foam
condensate tray, shaped in order
to optimize the air diffusion,
fire retardant rating B1 to DIN 4102.
Airfilter: synthetic washable filter, easily removable.
Condensatepump: float switch centrifugal pump with 650 mm of maximum head,
built into the unit and wired to the control panel on the outside of the casing.
Valveset: two or three way valves for ON/OFF operation, with pipe mounting kit
and thermostatic actuator.
MD-600versionmetal diffuser painted in RAL 9003white colour with 600x600 dimensionto perfectly fit into the false ceilingstandard modules without overlapping parts(800x800 model is not available)
Technicalcharacteristicsofthemaincomponents:
Airdiffuser:intake grid, frame and
adjustable air distribution louvers
on each side, made from ABS.
HTAversionwhite ABS, RAL 9003
HTBversionintake grid, frame and louversin a colour of choice
HTCversionintake grid and louversin a colour of choice,plus white ABS frame RAL 9003
HTDversionlouvers in a colour of choice,while the grid and frameare made from ABS, RAL 9003
SkyStarS
K-ECM
193
SK42-44/SK52-56(Version800x800)
Unit
Unit Diffuser
Diffuser
44
47
36
10 6 1050 400 1000 20039
WEIGHTSPACKED UNIT
kg kg kg kg A B C D
WEIGHTSPACKED UNIT
WEIGHTSUNPACKED UNIT
WEIGHTSUNPACKED UNIT
PACKED UNITDIMENSIONS (mm)
SK 42 SK 44 SK 52 - 56
MODEL
Dimensions and Weight
2pipeunits3. Flow, heating/cooling 3/4”
4. Return, heating/cooling 3/4”
4pipeunits1. Flow, heating 1/2”
2. Return, heating 1/2”
3. Flow, cooling 3/4”
4. Return, cooling 3/4”
SK12-14/SK22-26/SK32-36(Version600x600)
Unit
MD-600metaldiffuser
Diffuser
28
30
22
6 3 790 350 750 15024
WEIGHTSPACKED UNIT
kg kg kg kg A B C D
WEIGHTSPACKED UNIT
WEIGHTSUNPACKED UNIT
WEIGHTSUNPACKED UNIT
PACKED UNITDIMENSIONS (mm)
SK 12 SK 14 SK 22 - 26 SK 32 - 36
MODEL
Dimensions and Weight
2pipeunits3. Flow, heating/cooling 1/2”
4. Return, heating/cooling 1/2”
4pipeunits1. Flow, heating 1/2”
2. Return, heating 1/2”
3. Flow, cooling 1/2”
4. Return, cooling 1/2”
SkyStarS
K-ECM
195
3101,841,352,223,753174,94
33245
1,4
3802,171,612,674,513736,65,539308
1,4
5352,752,093,445,8247310,18,74738161,4
3102,241,572,554,283854,63,633245
2,1
4453,052,173,586,015249,46,64334112,1
7104,333,185,248,8174415,113,15445312,1
3602,561,812,964,964415,94,737287
2,1
6103,872,814,637,7966612,410,55041212,1
8805,023,746,2
10,4286419,717,76051622,1
6304,213,035,118,6172310,98,73324103,0
8705,153,776,3510,7288515,612,83930173,0
11656,334,728,0113,54108922,719,54839333,0
7105,293,695,899,879099,47,23425104,0
11307,725,538,8314,82132818,514,94738324,0
177010,757,9412,7321,37184833,628,857481084,0
AA
AA
AA
AA
AA
Speed
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CWater flowDp Cooling (E)Dp Heating (E)Sound power Lw (E)Sound pressure Lp (*)Fan (E)Water contentDimensionsEnergy classification FCEER (**)Energy classification FCCOP (***)
m3/hkWkWkWkWl/hkPakPa
dB(A)dB(A)
Wl
mm
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
575 x 575 x 275 820 x 820 x 303
SK–ECM 12 SK–ECM 22 SK–ECM 32 SK–ECM 42 SK–ECM 52MODEL
(E) = Eurovent certified performance. (*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec. (**) FCEER = Energy classification in Cooling. (***) FCCOP= Energy classification in Heating.
Speed
Air flowCooling total emission (E)Cooling sensible emission (E)Water flowDp Cooling (E)Heating (E)Water flowDp Heating (E)Sound power Lw (E)Sound pressure Lp (*)Fan (E)Cooling water contentHeating water contentDimensionsEnergy classification FCEER (**)Energy classification FCCOP (***)
m3/hkWkWl/hkPakWl/hkPa
dB(A)dB(A)
Wll
mmAA
AA
AB
AA
AA
3101,851,343184,6
2,432095,733245
1,40,7
3802,181,63756,2
2,852457,639308
1,40,7
5352,772,084769,5
3,6231111,74738161,40,7
3102,091,493593,51,981703,533245
1,70,5
4452,812,044835,72,532175,54334111,70,5
7103,932,9567610,53,35288
95445311,70,5
3602,381,714094,12,21894,537287
1,70,5
6103,532,626088,43,062637,55041211,70,5
8804,533,4677913,13,79326116051621,70,5
6304,33,087409,46,1452810,53324103,01,4
8705,283,8490813,67,5464915,53930173,01,4
11656,514,83112019,89,3680522,54839333,01,4
7104,983,528568,85,224496,53425103,61,1
11307,175,2
123317
7,16616114738323,61,1
17709,877,4
169730,19,518181857481083,61,1
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
575 x 575 x 275 820 x 820 x 303
SK–ECM 14 SK–ECM 26 SK–ECM 36 SK–ECM 44 SK–ECM 56MODEL
All the SkyStar ECM unitscan be supplied in MB version.
This version allowsa wide range of controls,
including the infra-red remote control,which can manage
one single unit or several unitsby using the Modbus RTU - RS 485
communication protocol.SK-E
CM-M
B
Other available Versions
The MCT version has been designed for all environments where false ceilingsare not featured or cannot be constructed.
The cover cabinet fits perfectly to the air intake and outlet diffuser, maintainingthe appealing design that defines the SkyStar series.
The water fittings can be turned to point upwards.The MCT series includes 7 models, with an installation height of up to 5 m,
thanks to the highly flexible adjustment of the air distribution louvers.All the technical specifications described on the previous pages remain the same,
while keeping in mind that the MCT series features one coil only(two pipe systems), there is no possibility of fresh air intake,
there is no possibility of additional electric heater.The MCT version features a special casing delivered in separate packaging;
this must only be fitted after having installed the SkyStar unitand completed the water and electrical connections.
MCT(E)(E)
(E)(E)
Certificationwww.eurovent-certification.com
www.certiflash.com
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
2pipeunits.The following standard rating conditions are used:
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CWater temperature: +70°C E.W.T. +60°C L.W.T.
4pipeunits.The following standard rating conditions are used:
SkyStarS
K-ECM
197
T-MB RT03
SK-ECMversion
Wall electronic controls
SK-ECM-MBversion
Electronic controls
NOTES: for more details about the Controls, see Page 225.
SkyStarS
K-ECM
SK42-44/52-56
SK42-44/52-56
SK42-44/52-56
SK42-44/52-56
SK12-14/22-26/32-36
SK12-14/22-26/32-36
SK12-14/22-26/32-36
SK12-14/22-26/32-36
Accessories
3 way ON-OFF valveswith simplified kit
Valve set, 3 ways, ON-OFF,with thermoelectric actuator.
The set includes connection pipes.
2 way ON-OFF valveswith micrometric lockshield valve
Valve set, 2 ways, ON-OFF,with thermoelectric actuator.
The set includesconnection pipes and holders.
3 way ON-OFF valveswith micrometric lockshield valve
Valve set, 3 ways, ON-OFF,with thermoelectric actuator.
The set includesconnection pipes and holders.
2 way ON-OFF valveswith simplified kit
Valve set, 2 ways, ON-OFF,with thermoelectric actuator.
The set includes connection pipes.
Fresh air kit
This is used to introducefresh air into the environmentdirectly through the diffuser.
PRT
Fresh air connectionCAP
Air distribution connectionCDA
Multifunction control (to be used with SK-ECM-MB version only)PSM-DI
RT03 infra-red remote control supplied with separate packaging (to be used with SK-ECM-MB version only)RT03
Wall control (to be used with SK-ECM-MB version only)T-MB RT03 infra-red remote control with receiver supplied with separate packaging (to be used with SK-ECM-MB version only)
Receiver for RT03 infra-red remote control supplied with separate packaging (to be used with SK-ECM-MB version only)
Receiver for RT03 infra-red remote control and MD-600 metal diffuser supplied with separate packaging (to be used with SK-ECM-MB version only)
RCS-RT03
RCS
RS
Sabianet (to be used with SK-ECM-MB version only)
Router for Sabianet
Relay output board for Sabianet
SabianetROUTER-S
SIOS
Sabianetmanagementsystemforanetworkoffancoils
Continuous fan speed control with electronic thermostat and summer/winter switch
Continuous fan speed control with electronic thermostat and summer/winter switch
Power unit for CR-T-ECM and CR-DI-ECM remote control, fitted on the unit
Power unit for CR-T-ECM and CR-DI-ECM remote control, not fitted on the unit
CR-T-ECMCR-DI-ECMUPM-ECMUPS-ECM
199
Every unit can be supplied
with 1 coil (2 pipe system) and possibly
an electric heating element,
or with 2 coils (4 pipe system)
with one or two rows heating coil,
for low temperature hot water.
Freshairmaybemixedwith room air.
Acondensatepumpmay also be supplied as an accessory.
In addition to the conventional temperature and speed control systems,
there is also the possibility ofautomatic speed selection
and to control operation of each unit through a single remote control
with central supervisor software installed on a PC(calledSabianet).
It is also possible to use the completelywirelesselectronic control system
based on radio communication, called FreeSabiana, with great advantages in terms
of installation flexibility and maximum precision in measuring room temperature.
TheCarismaCoanda one way Cassette fan coil units
are available in 3sizes. Thanks to the particular air handling section,
the units generate an airflowwitha“coanda”effect.The unit is suitable for installation in a suspended ceiling.
Air intake is from the bottom while the air supply is parallel to the ceiling,
through practical and functional intake and outlet grids.
The “coanda” effect creates
excellentcirculationoftheair inside the room.
Caris
maCoanda
OneWayCassetteFanCoilUnitwithAsynchronousMotor
CarismaCoanda
201
298
592
309
72
EA
F
F
E
100
WATER
INLET
WATER
OUTLET
A
592
A
592
A
592
Dimensions, Weight, Water content
1619221821
3338433540
4248544551
ROW
S
34
+1+2
ROW
S
WEIGHT WITH PACKAGING WEighT WiThouT pACKAging
1820232023
3440463742
4451584854
59245478
750
97088443
1130
1192109946,51350
0,60,80,20,4
1,31,70,40,8
1,72,40,51,0
AEFW
33+13+2
44+1
MODEL
MODEL
MODEL
1 2 3
1 2 3
1 2 3 1 2 3
Watercontent(litres)
Size13Diffusers
Size25Diffusers
Size36Diffusers
Technicalcharacteristicsofthemaincomponents:Casing: made from galvanized steel
insulated with polyolefin (PO) foam (class M1).
Diffuserwithintakegrid:in prepainted metal sheet
in RAL 9003 colour with intake grid
that can be opened for inspection
and maintenance of the air filter.
Airfilter: polypropylene
cellular fabric regenerating filter.
Fanassembly: the fans have aluminium or plastic blades
directly keyed on the motor with double aspiration and they are dynamically
and statically balanced during manufacture in order to have an extremely quiet operation.
Electricmotor: the motor is wired for single phase and has sixspeeds,threeofwhichareconnected,with capacitor. The motor is fitted
on sealed for life bearings and is secured on anti-vibration and self-lubricating mountings.
Internal thermal protection with automatic reset, protection IP 20, class B.
Coil: it is manufactured from drawn copper tube
and the aluminium fins are mechanically bonded onto the tube by an expansion process.
The coil has two 1/2 inch BSP internal connections and 1/8 inch BSP air vent and drain.
The coil is not suitable for use in corrosive atmosphere
or in environments where aluminium may be subject to corrosion.
Theconnectionsidecannotbechangedonsite.
Condensatecollectiontray: made from plastic with an “L”-shape
fitted on the inner casing; the tray is insulated with polyolefin (PO) foam (class M1).
The outside diameter of the condensate discharge pipe is 15 mm.
Rounddiffuser: the units are supplied with
round diffusers suitably designed to generate
an airflow with “coanda” effect.
Thedirectionofdiffuserairflowcanbeadjustedonsite.
Weight(kg)
Caris
maCoanda
Dimension(mm)
203
1400,880,660,922,41,6163526
1801,060,811,083,32,1224132
2201,260,981,254,52,7324637
2451,351,061,345,13,1384940
2801,501,181,476,13,6495243
3051,601,271,566,84,0665546
2001,371,001,492,90,9243324
2401,621,191,713,91,2273627
3051,971,472,025,51,6344233
3802,371,772,357,62,0444839
4702,812,132,7310,32,6575445
5603,232,473,0713,13,2715748
2901,971,442,126,42,0273526
3602,371,742,478,82,6334132
4402,842,112,8712,13,4424637
5403,342,513,3016,24,3595243
6203,752,833,6419,85,1725546
6804,053,073,8922,75,8845748
1 (E)
MIN
2 (E)
MED
3 4 5 (E)
MAX
6 1 (E)
MIN
2 (E)
MED
3 4 (E)
MAX
5 6 1 (E)
MIN
2 3 (E)
MED
4 (E)
MAX
5 6Speed
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Dp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*)
m3/hkWkWkWkPakPaW
dB(A)dB(A)
MODEL CCN 13+1 CCN 23+1 CCN 33+1
(E) = Eurovent certified performance. MIN-MED-MAX = Standard connected speeds.(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
1400,880,661,081,842,41,8163526
1801,060,811,332,263,32,6224132
2201,260,981,592,714,53,5324637
2451,351,061,732,945,14,0384940
2801,501,181,933,296,14,9495243
3051,601,272,083,546,85,6665546
1400,970,711,141,924,73,7163526
1801,190,881,422,376,75,4224132
2201,441,071,722,899,27,6324637
2451,551,171,883,1410,68,8384940
2801,741,312,103,5212,910,7495243
3051,871,422,273,8014,612,3665546
2001,371,001,602,682,92,3243324
2401,621,191,913,203,93,1273627
3051,971,472,353,955,54,5344233
3802,371,772,864,797,66,3444839
4702,812,133,435,7710,38,4575445
5603,232,473,956,6413,110,8715748
2001,441,041,692,824,43,5243324
2401,721,242,033,406,04,8273627
3052,121,542,544,258,67,1344233
3802,571,883,125,2212,110,2444839
4703,092,283,796,3716,813,6575445
5603,582,674,447,4621,717,9715748
2901,971,442,303,856,45,2273526
3602,371,742,794,678,87,3334132
4402,842,113,375,6512,19,8424637
5403,342,514,026,7316,213,4595243
6203,752,834,537,6119,816,3725546
6804,053,074,888,2022,718,6845748
2902,051,482,383,964,73,9273526
3602,491,812,904,836,75,5334132
4403,002,203,515,879,37,3424637
5403,562,634,207,0412,610,0595243
6204,022,984,778,0015,512,6725546
6804,363,255,208,7217,914,6845748
1 (E)
MIN
2 (E)
MED
3 4 5 (E)
MAX
6
1 (E)
MIN
2 (E)
MED
3 4 5 (E)
MAX
6
1 (E)
MIN
2 (E)
MED
3 4 (E)
MAX
5 6
1 (E)
MIN
2 (E)
MED
3 4 (E)
MAX
5 6
1 (E)
MIN
2 3 (E)
MED
4 (E)
MAX
5 6
1 2 (E)
MIN
3 4 (E)
MED
5 (E)
MAX
6
Speed
Speed
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*)
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*)
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
MODEL
MODEL
CCN 13
CCN 14
CCN 23
CCN 24
CCN 33
CCN 34
(E) = Eurovent certified performance. MIN-MED-MAX = Standard connected speeds.(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
Certificationwww.eurovent-certification.com
www.certiflash.com
Unitswith1rowadditionalcoil
Certificationwww.eurovent-certification.com
www.certiflash.com
Unitswith3and4rowcoil
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
2pipeunits.The following standard rating conditions are used:
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CWater temperature: +70°C E.W.T. +60°C L.W.T.
4pipeunits.The following standard rating conditions are used:
Caris
maCoanda
205
1 2 3 4 5 6 1 2 3 4 5 61 2 3 4 5 6
2,6
3,2
2,6
3,2
2,6
3,5
3,6
3
4,5
3,6
5,8
4,6
6,3
5
6,8
5,4
7,2
5,7
4,5
3,6
5,2
4,1
6,3
5
7,5
6
8,8
7
9,5
7,6
4
3,2
5
4
6,1
4,8
7
5,6
8
6,4
9
7,2
L
L
Installation Heightsand Air throwC1) Heating
C2) Cooling
SPEED
INSTALLATIONHEIGHT (m)
AIR THROW L (m)
Min.
Max.
C1
C2
MODEL
MODEL
CCN 1
CCN 1
CCN 2
CCN 2
CCN 3
CCN 3
Caris
maCoanda
NOTES: for more details about the Controls, see Page 225. for full list of main Accessories, see Page 235.
FreeSabianawirelesscontrolsystem
N.B.: if the electric heater is mounted, use the "IAQ" controls.
3 speed control
3 speed control with electronic thermostat and manual summer/winter switch
3 speed control with electronic thermostat and summer/winter switch
Automatic speed control with electronic thermostat and summer/winter switch
Automatic speed control with electronic thermostat, summer/winter switch and liquid crystal display
Automatic speed control with electronic thermostat to be mounted in the DIN 503 box (for units with valves)
Electromechanical thermostat with summer/winter switch (only for 2 pipe units)
MO-3VCR-T
TMO-TTMO-T-AU
TMO-DI
TMO-503-SV2T2T
Wall electronic controlsStandardmodels
Remote control to be used with electronic boards described at Page 229Free-Com
Electronic controls for MB boards
Sabianet (to be used with MB board only)
Router for Sabianet
Relay output board for Sabianet
SabianetROUTER-S
SIOS
MB electronic board fitted on the unit
MB electronic board supplied with separate packaging
Wall control (to be used with MB board only)
RT03 infra-red remote control with receiver supplied with separate packaging (to be used with MB board only)
RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Receiver for RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Multifunction control (to be used with MB board only)
MB-MMB-ST-MB
RS-RT03RT03RS
PSM-DI
Sabianetmanagementsystemforanetworkoffancoils
207
Every unit is supplied
with an electronic motor with
extremely low energy consumption,
brushless and sensorless type,
controlled by an inverter board.
By continuously varying the air flow,
the ambient temperature can be
more precisely monitored and regulated,savingover50%of the electricity used and reducing the average perceived noise level.
Every unit can be supplied with 1 coil (2 pipe system)
and possibly an electric heating element, or with 2 coils (4 pipe system)
with one or two rows heating coil, for low temperature hot water.
Freshairmaybemixed with room air.
Acondensatepumpmay also be supplied as an accessory.
In addition to the conventional
temperature and speed control systems,
there is also the possibility
to controloperation of each unit
through a single remote control
with central supervisor software installed on a PC
(calledSabianet).
Technicalcharacteristicsofthemaincomponents:ForthetechnicalcharacteristicsofthevariouscomponentsrefertoCarismaCOANDAFanCoilUnit,exceptforElectronicmotor: three phase permanent magnet brushless electronic
motor that is controlled with current reconstructed according to a BLAC sinusoidal wave.
The inverter board that controls the motor operation
is powered by 230 Volt, single-phase and, with a switchingsystem, it generates
a three-phase frequency modulated, wave form power supply.
The electric power supply required for the machine
is therefore single-phase with voltage of 230-240V and frequency of 50-60Hz.
TheCarismaCoanda-ECM one way Cassette fan coil units
are available in 3sizes.Thanks to the particular air handling section,
the units generate an airflowwitha“coanda”effect.The variable flow rate enhances the product's main virtues:
excellentaircirculation, with a high degree of comfort,
especially during the summer months.
OneWayCassetteFanCoilUnitwithECBrushlessElectronicMotorandInverterBoard
CarismaCoanda-ECM
Caris
maCoanda-ECM
209
298
592
309
72
EA
F
F
E
100
WATER
INLET
WATER
OUTLET
A
592
A
592
A
592
L
L
1 2 3 4 5 6 1 2 3 4 5 61 2 3 4 5 6
2,6
3,2
2,6
3,2
2,6
3,5
3,6
3
4,5
3,6
5,8
4,6
6,3
5
6,8
5,4
7,2
5,7
4,5
3,6
5,2
4,1
6,3
5
7,5
6
8,8
7
9,5
7,6
4
3,2
5
4
6,1
4,8
7
5,6
8
6,4
9
7,2
Installation Heightsand Air throwC1) Heating
C2) Cooling
SPEED
INSTALLATIONHEIGHT (m)
AIR THROW L (m)
Min.
Max.
C1
C2
MODEL
MODEL
CCN 1
CCN 1
CCN 2
CCN 2
CCN 3
CCN 3
Dimensions, Weight, Water content
1619221821
3338433540
4248544551
ROW
S
34
+1+2
ROW
S
WEIGHT WITH PACKAGING WEighT WiThouT pACKAging
1820232023
3440463742
4451584854
59245478
750
97088443
1130
1192109946,51350
0,60,80,20,4
1,31,70,40,8
1,72,40,51,0
AEFW
33+13+2
44+1
MODEL
MODEL
MODEL
1 2 3
1 2 3
1 2 3 1 2 3
Size13Diffusers
Size25Diffusers
Size36Diffusers
Watercontent(litres)
Weight(kg)
Caris
maCoanda-ECM
Dimension(mm)
211
Wall electronic controls
Electronic controls for MB boards
CD
BB
BB
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
2751,871,372,045,81,8103627
3452,311,702,428,42,5134233
4302,782,062,8211,73,3194839
5253,282,453,2415,74,2295445
6203,752,833,6419,85,1425849
2151,461,071,583,21,083425
2951,921,421,975,21,5114031
3702,311,732,317,32,0164637
4502,742,072,669,82,5245243
5403,162,413,0112,63,1375647
1300,820,620,872,11,483526
1651,000,761,033,01,9114132
2051,180,911,184,02,5144637
2501,371,071,355,23,1215142
2951,561,241,526,53,8295546
Inverter Power (V)
Speed
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Dp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*)Energy classification FCEER (**)Energy classification FCCOP (***)
m3/hkWkWkWkPakPaW
dB(A)dB(A)
MODEL CCN–ECM 13+1 CCN–ECM 23+1 CCN–ECM 33+1
CC
BB
BB
CC
BB
BB
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
1 (E)
MIN
3 5 (E)
MED
7,5 10 (E)
MAX
2751,871,372,193,655,84,7103627
3452,311,702,724,548,46,9134233
4302,782,063,305,5311,79,4194839
5253,282,453,936,5915,712,9295445
6203,752,834,547,6119,816,6425849
2751,951,412,253,754,33,5103627
3452,421,762,824,706,45,2134233
4302,942,153,445,748,97,4194839
5253,492,574,126,8912,110,0295445
6204,022,984,788,0015,513,0425849
2151,461,071,722,883,22,683425
2951,921,422,283,825,24,2114031
3702,311,732,794,677,36,0164637
4502,742,073,335,609,88,0245243
5403,162,413,856,4912,610,4375647
2151,551,111,823,045,04,183425
2952,061,492,464,118,26,7114031
3702,511,843,035,0811,69,4164637
4503,002,213,686,1715,913,2245243
5403,502,604,327,2720,817,1375647
1300,820,621,021,722,11,783526
1651,000,761,252,123,02,4114132
2051,180,911,502,544,03,3144637
2501,371,071,752,985,24,3215142
2951,561,242,023,446,55,3295546
1300,910,661,071,784,13,383526
1651,120,821,322,225,94,8114132
2051,340,991,602,688,16,6144637
2501,581,181,903,1910,99,0215142
2951,811,382,203,6913,911,6295546
Inverter Power (V)
Speed
Inverter Power (V)
Speed
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*)Energy classification FCEER (**)Energy classification FCCOP (***)
Air flowCooling total emission (E)Cooling sensible emission (E)Heating (E)Heating - Water 70-60°CDp Cooling (E)Dp Heating (E)Fan (E)Sound power (E)Sound pressure (*)Energy classification FCEER (**)Energy classification FCCOP (***)
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
m3/hkWkWkWkWkPakPaW
dB(A)dB(A)
MODEL
MODEL
CCN–ECM 13
CCN–ECM 14
CCN–ECM 23
CCN–ECM 24
CCN–ECM 33
CCN–ECM 34
(E) = Eurovent certified performance. (*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec. (**) FCEER = Energy classification in Cooling. (***) FCCOP= Energy classification in Heating.
(E)(E)
(E)(E)
(E)(E)
Certificationwww.eurovent-certification.com
www.certiflash.com
Unitswith1rowadditionalcoil
Certificationwww.eurovent-certification.com
www.certiflash.com
Unitswith3and4rowcoil
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
2pipeunits.The following standard rating conditions are used:
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CWater temperature: +70°C E.W.T. +60°C L.W.T.
4pipeunits.The following standard rating conditions are used:
Caris
maCoanda-ECM
NOTES: for more details about the Controls, see Page 225. for full list of main Accessories, see Page 235.
Continuous fan speed control with electronic thermostat and summer/winter switch
Continuous fan speed control with electronic thermostat and summer/winter switch
Power unit for CR-T-ECM and CR-DI-ECM remote control, fitted on the unit
Power unit for CR-T-ECM and CR-DI-ECM remote control, not fitted on the unit
CR-T-ECMCR-DI-ECMUPM-ECMUPS-ECM
Sabianet (to be used with MB board only)
Router for Sabianet
Relay output board for Sabianet
SabianetROUTER-S
SIOS
Sabianetmanagementsystemforanetworkoffancoils
MB electronic board fitted on the unit
MB electronic board supplied with separate packaging
Wall control (to be used with MB board only)
RT03 infra-red remote control with receiver supplied with separate packaging (to be used with MB board only)
RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Receiver for RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Multifunction control (to be used with MB board only)
MB-ECM-MMB-ECM-S
T-MBRS-RT03
RT03RS
PSM-DI
213
Caris
maFly
CarismaFly is the high wall fan coil unitdesignedandmanufacturedinItaly by Sabiana, in 4 sizes and many different
models. Fly is easy to install like a standard fan coil: without decreasing
the emission and without any extra frame, 2 way or 3 way valves
and condensate pump can be mounted into the casing.
Themodernandappealing design of the unit in RAL 9003 colour
allows the use of Fly in any environment.
Fly isavailablewithstandardACmotorsorlowenergyECmotors and in the following versions:
with wired wall control, infra-red remote control, MB electronic board
for Modbus management and electric heating coil.
Theunitsarefor2pipeinstallationsonly.All the Fly models perform very low electric consumption and extremely
quite sound levels according to the request of today’s new projects.
Technicalcharacteristicsofthemaincomponents:Versions: all versions are available
without valves, with 2 way valve or with 3 way valve fitted in the unit.
There are four sizes available in the following versions:
CVP without infra-red remote control and without valve;
CVP-2V without infra-red remote control with fitted 2 way valve;
CVP-3V without infra-red remote control with fitted 3 way valve.
CVP-T with infra-red remote control and without valve;
CVP-T-2V with infra-red remote control with fitted 2 way valve;
CVP-T-3V with infra-red remote control with fitted 3 way valve.
CVP-MB with MB board and without valve;
CVP-MB-2V with MB board with fitted 2 way valve;
CVP-MB-3V with MB board with fitted 3 way valve.
Casing: made of auto-extinguishing ABS UL94 HB plastic with high specifications
and great resistance to aging.
Filter: washable-regenerable synthetic filter, readily accessible.
Fanassembly: made of plastic tangential fan.
Electricmotor: the motor is for single phase supply and has six speeds,
three of which are connected, with capacitor. The motor is fitted on sealed for life bearings
and is secured on anti-vibration and self-lubricating mountings.
Internal thermal protection with automatic reset, protection IP 20, class B.
The speeds connected in the factory
are indicated by “MIN, MED and MAX” in the following tables.
Coil: it is manufactured from drawn copper tube
and the aluminium fins are mechanically bonded onto the tube by an expansion process.
The coil has two 1/2 inch BSP internal connections and 1/8 inch BSP air vent and drain.
The heat exchanger is not suitable for use in corrosive atmosphere or in environments
where aluminium may be subject to corrosion.
Theconnectionsareontheleftsidefacingtheunitonly.
Condensatecollectiontray: made from polypropylene; the outside diameter
of the condensate discharge pipe is 16mm.
Installationtemplate: a cardboard installation template is supplied with every unit
to help the mounting on the wall.
HighWallFanCoilUnitCarismaFly
215
A
322
A 212
322
ATTA
CC
HI I
DR
AU
LIC
IA
SIN
IST
RA
34
164
58
199
ø16
97
8 31
1
12 97 12
322
8 31
1
34
37
ø16
34
164
58
199
92
92 20
276
C
16
281
B
WATER
INLET
WATER OUTLET
ø16
34
164
58
199
ø16
97
8 31
1
12 97 12
322
8 31
1
34
37
ø16
34
164
58
199
92
92 20
276
C
16
281
B
WATER
INLET
WATER OUTLET
ø16
Certificationwww.eurovent-certification.com
www.certiflash.com
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
The following standard rating conditions are used: Caris
maFly
1 (E)
MIN
205
1,24
0,92
1,60
4,8
3,7
12
35
26
1 (E)
MIN
280
1,89
1,35
2,26
11,2
8,7
16
35
26
2 (E)
MED
270
1,50
1,14
2,00
6,8
5,5
14
41
32
2 (E)
MED
375
2,32
1,69
2,84
16,2
12,6
21
40
31
3
340
1,76
1,36
2,39
9,0
7,2
17
46
37
3
480
2,78
2,06
3,49
22,5
17,7
26
45
36
4 (E)
MAX
375
1,87
1,46
2,58
10,1
8,3
18
48
39
4 (E)
MAX
545
3,03
2,27
3,86
26,2
21,2
29
48
39
5
470
2,15
1,72
3,04
13,0
10,6
24
52
43
5
730
3,63
2,81
4,79
36,4
29,3
38
55
46
6
500
2,23
1,80
3,17
13,9
10,8
30
53
44
6
780
3,78
2,95
5,03
39,1
31,9
46
57
48
1 (E)
MIN
250
1,43
1,07
1,88
6,2
4,8
12
39
30
1
300
1,99
1,43
2,40
12,3
9,7
17
36
27
2
305
1,63
1,25
2,20
7,9
6,4
14
43
34
2 (E)
MED
440
2,62
1,93
3,26
20,2
15,9
23
43
34
3 (E)
MED
365
1,84
1,43
2,39
9,8
7,2
18
47
38
3
500
2,86
2,12
3,61
23,6
19,1
27
46
37
4
400
1,95
1,53
2,70
10,9
8,5
20
49
40
4 (E)
MED
610
3,26
2,47
4,20
29,9
23,7
32
51
42
5 (E)
MAX
480
2,18
1,75
3,09
13,3
10,9
24
53
44
5
675
3,46
2,66
4,53
33,4
27,2
35
54
45
6
545
2,35
1,92
3,38
15,2
12,5
32
55
46
6 (E)
MAX
790
3,81
2,98
5,07
39,7
31,5
48
57
48
MODEL
MODEL
1
3
2
4
Speed
Air flow
Cooling total emission (E)
Cooling sensible emission (E)
Heating (E)
Dp Cooling (E)
Dp Heating (E)
Fan (E)
Sound power Lw (E)
Sound pressure Lp (*)
Velocità
Portata aria
Raffreddamento resa totale (E)
Raffreddamento resa sensibile (E)
Riscaldamento (E)
Dp Raffreddamento (E)
Dp Riscaldamento (E)
Assorbimento Motore (E)
Potenza acustica Lw (E)
Pressione acustica Lp (*)
m3/h
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
m3/h
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
(E) = Eurovent certified performance. MIN-MED-MAX = Standard connected speeds.(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
10
10
13
13
11
11
14
14
0,85
0,85
1,28
1,28
678
678
983
983
880
880
1185
1185
691
691
996
996
WEIGHT without valvesKg
WEIGHT with valvesKg
WATER CONTENTLitres
Bmm
Amm
Cmm
1234
MODEL
Dimensions, Weight, Water content
Mountingdimensions
Coilconn
ectio
nsonleleft
217
2 way valve
Control valve kit:2 way valve, ON-OFF,
with electric motor and mounting kit.
Condensate drain pump
Accessories
3 way valve
Control valve kit:3 way valve, 230V ON-OFF,
with electric motor and mounting kitwith micrometric lockshield valve.
Caris
maFly
NOTES: for more details about the Controls, see Page 225.
N.B.: if the electric heater is mounted, use the "IAQ" controls.
Wall electronic controls
3 speed control
3 speed control with electronic thermostat and manual summer/winter switch
3 speed control with electronic thermostat and summer/winter switch
Automatic speed control with electronic thermostat and summer/winter switch
Automatic speed control with electronic thermostat to be mounted in the DIN 503 box (for units with valves)
Electromechanical thermostat with summer/winter switch (only for 2 pipe units)
MO-3VCR-T
TMO-TTMO-T-AU
TMO-503-SV2T2T
CVPversion
CVP-MBversion Wall control (to be used with MB board only)
RT03 infra-red remote control with receiver supplied with separate packaging (to be used with MB board only)
RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Receiver for RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Multifunction control (to be used with MB board only)
T-MBRS-RT03-F
RT03RS-F
PSM-DI
Electronic controls for MB boards
Hardware/software supervisory system (to be used with MB board only)
Router for Sabianet
Relay output board for Sabianet
SabianetROUTER-S
SIOS
Sabianetmanagementsystemforanetworkoffancoils
219
Caris
maFly-ECM
Technicalcharacteristicsofthemaincomponents:Versions: all versions are available
without valves, with 2 way valve or with 3 way valve fitted in the unit.
There are four sizes available in the following versions:
CVP-ECM without infra-red remote control and without valve;
CVP-ECM-2V without infra-red remote control with fitted 2 way valve;
CVP-ECM-3V without infra-red remote control with fitted 3 way valve.
CVP-ECM-T with infra-red remote control and without valve;
CVP-ECM-T-2V with infra-red remote control with fitted 2 way valve;
CVP-ECM-T-3V with infra-red remote control with fitted 3 way valve.
CVP-ECM-MB with MB board and without valve;
CVP-ECM-MB-2V with MB board with fitted 2 way valve;
CVP-ECM-MB-3V with MB board with fitted 3 way valve.
Casing: made of auto-extinguishing ABS UL94 HB plastic with high specifications
and great resistance to aging.
Filter: washable-regenerable synthetic filter, readily accessible.
Fanassembly: made of plastic tangential fan.
Electronicmotor: three phase permanent magnet brushless electronic
motor that is controlled with current reconstructed according to a BLAC sinusoidal wave.
The inverter board that controls the motor operation
is powered by 230 Volt, single-phase and, with a switchingsystem, it generates
a three-phase frequency modulated, wave form power supply.
The electric power supply required for the machine
is therefore single-phase with voltage of 230-240V and frequency of 50-60Hz.
Coil: it is manufactured from drawn copper tube
and the aluminium fins are mechanically bonded onto the tube by an expansion process.
The coil has two 1/2 inch BSP internal connections and 1/8 inch BSP air vent and drain.
The heat exchanger is not suitable for use in corrosive atmosphere or in environments
where aluminium may be subject to corrosion.
Theconnectionsareontheleftsidefacingtheunitonly.
Condensatecollectiontray: made from polypropylene; the outside diameter
of the condensate discharge pipe is 16mm.
Installationtemplate: a cardboard installation template is supplied with every unit
to help the mounting on the wall.
HighWallFanCoilUnitwithECBrushlessElectronicMotorandInverterBoard
CarismaFly-ECM
CarismaFly is the high wall fan coil unitdesignedandmanufac-turedinItaly by Sabiana, in 4 sizes and many different models. Fly is
easy to install like a standard fan coil: without decreasing the emission and
without any extra frame, 2 way or 3 way valves and condensate pump can
be mounted into the casing. Themodernandappealing design of
the unit in RAL 9003 colour allows the use of Fly in any environment. Fly is
availablewithlowenergyECmotors and in the following versions:
with infra-red remote control, MB electronic board for Modbus management
and electric heating coil. Theunitsarefor2pipeinstallationsonly. All the Fly models perform very low electric consumption and extremely
quite sound levels according to the request of today’s new projects.
221
A
322
A 212
322
ATTA
CC
HI I
DR
AU
LIC
IA
SIN
IST
RA
34
164
58
199
ø16
97
8 31
1
12 97 12
322
8 31
1
34
37
ø16
34
164
58
199
92
92 20
276
C
16
281
B
WATER
INLET
WATER OUTLET
ø16
34
164
58
199
ø16
97
8 31
1
12 97 12
322
8 31
1
34
37
ø16
34
164
58
199
92
92 20
276
C
16
281
B
WATER
INLET
WATER OUTLET
ø16
10
10
13
13
11
11
14
14
0,85
0,85
1,28
1,28
678
678
983
983
880
880
1185
1185
691
691
996
996
WEIGHT without valvesKg
WEIGHT with valvesKg
WATER CONTENTLitres
Bmm
Amm
Cmm
1234
MODEL
1 (E)
MIN
270
1,83
1,31
2,20
10,7
8,5
6
37
28
3
345
2,20
1,60
2,69
14,8
11,7
8
42
33
5 (E)
MED
420
2,53
1,86
3,15
19,0
15,1
11
45
36
7,5
520
2,93
2,19
3,72
24,8
19,9
15
49
40
10 (E)
MAX
620
3,29
2,50
4,25
30,4
24,2
20
53
44
1 (E)
MIN
375
2,34
1,70
2,87
16,5
12,6
9
43
34
3
465
2,72
2,01
3,41
21,6
17,2
12
46
37
5 (E)
MED
550
3,05
2,29
3,88
26,6
21,2
16
49
40
7,5
665
3,43
2,63
4,48
32,9
26,6
22
53
44
10 (E)
MAX
770
3,75
2,92
4,99
38,7
31,4
30
57
48
1 (E)
MIN
190
1,17
0,86
1,50
5,0
4,2
6
35
26
3
240
1,39
1,04
1,82
6,3
5,4
7
39
30
5 (E)
MED
290
1,58
1,20
2,12
7,7
6,5
9
46
37
7,5
355
1,81
1,40
2,48
9,5
8,2
11
48
39
10 (E)
MAX
415
2,00
1,57
2,78
11,2
9,3
15
52
43
1 (E)
MIN
260
1,47
1,10
1,94
6,9
5,6
7
40
31
3
315
1,67
1,28
2,25
8,4
6,9
9
44
35
5 (E)
MED
375
1,87
1,46
2,58
10,1
8,5
12
47
38
7,5
440
2,07
1,64
2,90
11,8
9,7
16
51
42
10 (E)
MAX
510
2,26
1,83
3,23
13,7
11,6
21
55
46
Caris
maFly-ECM
MODEL
MODEL
1
3
2
4
Inverter Power (V)
Speed
Air flow
Cooling total emission (E)
Cooling sensible emissio (E)
Heating (E)
Dp Cooling (E)
Dp Heating (E)
Fan (E)
Sound power Lw (E)
Sound pressure Lp (*)
Inverter Power (V)
Speed
Air flow
Cooling total emission (E)
Cooling sensible emissio (E)
Heating (E)
Dp Cooling (E)
Dp Heating (E)
Fan (E)
Sound power Lw (E)
Sound pressure Lp (*)
m3/h
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
m3/h
kW
kW
kW
kPa
kPa
W
dB(A)
dB(A)
(E) = Eurovent certified performance. MIN-MED-MAX = Standard connected speeds.(*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
Dimensions, Weight, Water content
Mountingdimensions
Coilconn
ectio
nsonleleft
Certificationwww.eurovent-certification.com
www.certiflash.com
COOLING (summer mode)
Entering air temperature: +27°C d.b. +19°C w.b.Water temperature: + 7°C E.W.T. +12°C L.W.T.
HEATING (winter mode)
Entering air temperature: +20°CEntering water temperature: +50°C
Water flow rate as for the cooling conditions
The following standard rating conditions are used:
223
2 way valve
Control valve kit:2 way valve, ON-OFF,
with electric motor and mounting kit.
Condensate drain pump
Accessories
3 way valve
Control valve kit:3 way valve, 230V ON-OFF,
with electric motor and mounting kitwith micrometric lockshield valve.
Caris
maFly-ECM
NOTES: for more details about the Controls, see Page 225.
CVP-ECM-MBversion Wall control (to be used with MB board only)
RT03 infra-red remote control with receiver supplied with separate packaging (to be used with MB board only)
RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Receiver for RT03 infra-red remote control supplied with separate packaging (to be used with MB board only)
Multifunction control (to be used with MB board only)
T-MBRS-RT03-F
RT03RS-F
PSM-DI
Electronic controls for MB boards
Hardware/software supervisory system (to be used with MB board only)
Router for Sabianet
Relay output board for Sabianet
SabianetROUTER-S
SIOS
Sabianetmanagementsystemforanetworkoffancoils
225
CB-IAQ
CB-R-IAQ
CB-AU-IAQ
CB CB-T
CB-C
CB-A
U
CB-IA
Q
CB-R
-IAQ
CB-A
U-IA
Q
IDENTIFICATION
CB
CB-AUCB-T
CB-C
forCarismaCRC-CRT-CRRversionswithcasing
Built-in electronic controlsforFanCoilswithAsynchronousMotor
Installation of bimetallic low temperature cut-out thermostat (TMM)
Installation of electronic low temperature cut-out thermostat (TME)
Room thermostat for fan and electric heater control (not for Crystall)
Room thermostat for chilled water valve (SUMMER) and electric heater (WINTER) control(in winter only the electric heater is working)
Simultaneous thermostatic control of the valves and fan
Room thermostat for 1 valve control (2 pipe installation)
Room thermostat for 2 valve control (4 pipe installation)
Room thermostat for fan control (ON-OFF)
Automatic Summer/Winter switch with neutral zone for 4 pipe installation with 2 valves
Remote centralized Summer/Winter switch or by an automatic change-over fitted on the water pipe
Summer/Winter switch
Manual/Automatic 3 speed selection
Manual 3 speed switch
ON-OFF switch for Crystall electrostatic filter or electric heater
ON-OFF switch
FUNCTIONS
Controls
227
IDENTIFICATION
TMO-
T-AU
-IAQ
MO-
3V
CR-T
TMO-
T
TMO-
T-AU
TMO-
503-
SV2
TMO-
DI
T2T
MO-
3V-IA
Q
TMO-
T-IA
Q Controls
Installation of bimetallic low temperature cut-out thermostat (TMM)
Installation of electronic low temperature cut-out thermostat (TME)
Room thermostat for fan and electric heater control (not for Crystall)
Room thermostat for chilled water valve (SUMMER) and electric heater (WINTER) control(in winter only the electric heater is working)
Simultaneous thermostatic control of the valves and fan
Room thermostat for 1 valve control (2 pipe installation)
Room thermostat for 2 valve control (4 pipe installation)
Room thermostat for fan control (ON-OFF)
Automatic Summer/Winter switch with neutral zone for 4 pipe installation with 2 valves
Remote centralized Summer/Winter switch or by an automatic change-over fitted on the water pipe
Summer/Winter switch
Manual/Automatic 3 speed selection
Manual 3 speed switch
ON-OFF switch for Crystall electrostatic filter or electric heater
ON-OFF switch
FUNCTIONS
forallCarisma-SkyStar-MaestroRange
Wall electronic controlsforFanCoilswithAsynchronousMotor
TMO-DI
T2T
MO-3V-IAQ
TMO-T-IAQ
TMO-503-SV2
TMO-T-AU-IAQ
MO-3V
TMO-T-AU
CR-T
WM-AU (Spring 2014)
TMO-T
229
T-MB control
RT03infra-red remote control
All Carisma and SkyStar units can be supplied with a microprocessor
management and control unit withinfra-redremotecontrolwith liquid crystal display or with aT-MBwallmounted
controlunitcombined with theMBboard.
foralltheCarismaandSkyStarRange
Free-Com Temperatureprobe
FreeSabianais an innovative, fullywireless,
electronic system
for use with fan coil units,
based on radio communication.
This technologyprovidesinstallationflexibilityandamoreaccuratemeasurementoftheroomtemperature. The probe
can be moved until the most suitable position is found, without the worry of
changes in the room layout and of its furniture and also without mounting it on a wall.
If a new fan coil unit is added, no electrical wiring
for the control system is required: just define the control unit and the probe
which regulates it. Theimprovedmeasurementaccuracyis a result of the possibility to position the probe near the user location:
this enables to keep the temperature exactly at the required value
with energy savings compared with a traditional measurement system.
Transmission is based on communication protocol
IEE802.15.4, the most suitable way to transmit a relatively low amount
of information with very low consumption and high reliability.
The system hasbeencertified by a leading independent body,
officially recognized by the EU authorities and its sale has been authorized
in all the EU and EFTA countries.
Maincomponents:A remotecontrol which features
a button panel and LCD display and can be wall mounted
or positioned on a dedicated table support.
It enables the control of all the operating variables
of the fan coil units in different configurations.
The control is battery powered.
The temperature and the operating speed of the fan coil unit
are set with two large buttons featuring user friendly graphics.
A powerunit to be installed on the fan coil
(fan coil interface). It controls the fan
and the valves of the fan coil. The power unit is connected
to the electric supply. The power unit receives
the information required to control the fan coil
both from the remote control and locally, such as the temperature of the coil.
A room temperatureprobe, which can be wall mounted
or positioned on a dedicated table support.
It is a battery powered device, able to measure the air temperature
in the spot where it is positioned, generating temperature information
which is communicated to the other devices.
RT03 infra-red remote controland T-MB wall mounted control
FreeSabianawireless control system
foralltheCarismaandSkyStarRange
Controls
Controls forFanCoilswithAsynchronousMotor
231
PSM-DI panel
Sabianet screenshot
PC
withAsynchronousMotorandwithECBrushlessElectronicMotorandInverterBoard
Another option available for the serial communication between the units is the possibility
to connect up to 60 Carisma and SkyStar units in series
(the maximum length of the connection cable must not exceed 800 m)
and manage them with just one wallmountedintelligentPSM-DIcontroller.The wall mounted controller can be used
to set the operating mode for each individual unit connected,
display the operating conditions of each individual unit,
and set the ON/OFF time sets for each day of the week.
If morethan60unitsneedtobeconnected,twoormore wall mounted intelligent controllers must be used.
Each unit must have aMBboard.
The MB boards, besides being used
with T-MB controls, with infra-red remote
control units, with PSM-DI and with
the units managed withSabianet software,
can also be interfaced
with BSM supervisory systems that use
Modbus communication protocol.
Sabianet is a centralised control system for networks of MB fan coils,
based on software that runs onLinuxoperatingsystem(the program is provided pre-installed on a PC).
The Sabianet software offersapracticalandeconomicalsolutionfor managing the fan coils, with the simple click of the mouse.
The main characteristics include simplicity of use,
an extremely complete and functional weekly program, and the possibility to access
the historical operating data for each individual unit connected.
foralltheCarismaandSkyStarRange
PSM-DI multifunction control panel
MB board
Sabianet management systemfor a network of fan coils
Controls for Fan Coil Units
foralltheCarismaandSkyStarRange
foralltheCarismaandSkyStarRange
Controls
233
Electronic controls for Fan Coil UnitswithECBrushlessElectronicMotorandInverterBoard
foralltheCarismaECMandSkyStarECMRange
foralltheCarismaECMandSkyStarECMRange
foralltheCarismaECMandSkyStarECMRange
RT03infra-red remote control
All Carisma and SkyStar units can be supplied with a microprocessor
management and control unit withinfra-redremotecontrolwith liquid crystal display or with aT-MBwallmounted
controlunitcombined with theMBboard.
RT03 infra-red remote controland T-MB wall mounted control
T-MB control
For the characteristics, see Page 231.
For the characteristics, see Page 230.
Sabianet management systemfor a network of fan coils
PSM-DI multifunction control
Controls
CB-T-ECM: for CRC–ECMandCRT–ECMversions.
CB-T-ECM-IAQ: for CRC–ECMversions.
CR-T-ECM: for CRC–ECM,CRT–ECM, CRS–ECM,CCN–ECMandSK–ECMversions.
CR-DI-ECM: for CRC–ECM,CRT–ECM, CRS–ECM,CCN–ECMandSK–ECMversions.
CB-T-ECM-IAQCB-T-ECM
CR-T-ECM
CR-DI-ECM
Room thermostat for chilled water valve (SUMMER) and electric heater (WINTER) control (in winter only the electric heater is working)
Continuous speed control based on the difference between ambient temperature and Set temperature (speed switch in Auto position)
FUNCTIONS
IDENTIFICATION
Room thermostat for fan and electric heater control (not for Crystall)
Installation of electronic low temperature cut-out thermostat (NTC)
Simultaneous thermostatic control of the valves and fan
Room thermostat for 1 valve control (2 pipe installation)
Room thermostat for 2 valve control (4 pipe installation)
Room thermostat for fan control (ON-OFF)
Remote centralized Summer/Winter switch or by an automatic change-over fitted on the water pipe
Summer/Winter switch
Manual 3 speed switch or automatic continuous speed control
ON-OFF switch
Built-in
CB-T
-ECM
CR-T
-ECM
CB-T
-ECM
-IAQ
CR-D
I-ECM
Wall
235
Simplified kitfor 3 way valve
for main and additional coil(concealed model only)
3 way valve, (ON-OFF)with electric motor and mounting kit.
Valve with flat connectionwithout micrometric lockshield valve.
Additional coil 3 way valve
Control valve kit:3 way valve, ON-OFF,
with electric motor and mounting kitwith micrometric lockshield valve.
Main coil 3 way valve
Control valve kit:3 way valve, ON-OFF,
with electric motor and mounting kitwith micrometric lockshield valve.
2 way valvefor main and additional coil
Control valve kit:2 way valve, ON-OFF,
with electric motor and mounting kit.
Electric heater(not available with Crystall filter)
1 PHASE 230VElectric heater with integral:
safety thermostat and relay control.
IV-IO
MV-MO-MVB-IV-IO
MV-MO-MVB-IV-IO
MV-MO-MVB-IV-IO
MV-MO-MVB-IV-IO
Model:
Model:
Model:
Model:
Model:
Version:
Version:
Version:
Version:
Version:
CRC
CRC
CRC
CRC
CRC
CRT
CRT
CRT
CRT
CRT
CRR
CRR
CRS
CRS
CRS
CRS
CRS
CCN
CCN
CCN
CCN
CCN
Accessories forCarismaCRC/CRT/CRR/CRS/CCN
VS
VBA
VBP
V2
BEL
All Sabiana Carisma fan coils,
whether withAsynchronousMotoror withElectronicMotorandInverter, can be
equipped with averylargeseriesofAccessories,such as, to name only the most common,
numerous types of regulating valves, sturdy support feet,
rear cover panel for installing against glass, additional
electrical resistances, auxiliary condensation drain pump,
outdoor air intake louvre, inlet and outlet ducts
and grills for ducted installations.
forCarismaFanCoilUnitsAccessories
Accessories
MV-MVB-IV MO-IOModel: Model:(notforCCN) (notforCRR)
BSV BSO
Extensioncondensate collection tray
to cover valve assembly
• BSV for vertical units • BSO for horizontal units
Version: CRC CRT CRR CRS CCN
BSVBSO
237
Fresh air mixing damper
Not mounted.
Can be motorized on request.
Fresh air mixing damper
Mounted on the unitwith feet and intake grid included.
Can be motorized on request.
Bottom closing panel(for horizontal units)
Belimo motor(not available with ECM range)
Fitted on the unitfor motorized working of the damper.
(available with “IAQ” control only)
Framefor buitl-in wall installation
Straight inlet flange
Can be usedtogether with GRAG air inlet grid.
Made of galvanized steel.
IV-IO
MV
MO-MVB
IV-IO
IV
IV-IO
Model:
Model:
Model:
Model:
Model:
Model:
Version:
Version:
Version:
Version:
Version:
Version:
CRC
CRC
CRC
CRC
CRC
CRC
CRT
CRT
CRT
CRT
CRT CRS
Accessories forCarismaCRC/CRT/CRR/CRS/CCN
SAE
SAEM
PCO
BESAE
IM
FRD
Accessories forCarismaCRC/CRT/CRR/CRS/CCN
Accessories
CRC
DRPV-C DRPO-C
CRT
CRS CCN
Feet
Plasticcondensate drain pipewith fast connection
Allows correct condensate drain.
Condensate pump:
• DRPV-C for vertical units • DRPO-C for horizontal units
Aluminiumlow intake grid
To be installed with PAP feet.
Frontal intake kit
Bottom closing paneland filter sliding guides.
Rear closing panel(for vertical units)
MV
MO-IO
MV-MVB-IV MO-IO
MV
IV-IO
MV-MVB
Model:
Model:
Model: Model:
Model:
Model:
Model:
Version:
Version:
Version:
Version:
Version:
Version:
CRC
CRC
CRC
CRC
CRC
CRC
CRT CRR
CRT
CRT
CRT
CRT CRS
CRT
CRS CCN
PAP
SCR
DRPV-CDRPO-C
GAP
KAF
PCV
239
All the plenums are suppliedwith spigots
for the connection of flexible ducts.
All the plenums are suppliedwith spigots
for the connection of flexible ducts.
Air inlet grid with filter
To be fittedto the FR 90 90° inlet flange.Made of anodized aluminium.
Spigot diffuser
Made of galvanized steelinsulated with polyethylene lining.
Air inlet spigot plenum
Made of galvanized steelinsulated with polyethylene lining.
Air inlet grid with filter
To be fittedto the FRD straight inlet flange.Made of anodized aluminium.
Condensate drain pump
Fresh air connection
IV-IO
IV-IO
IV-IO
IV-IO
Model:
Model:
Model:
Model:
Version:
Version:
Version:
Version:
Version:
Version:
CRC
CRC
CRC
CRC
CRC
CRS
CRS
CCN
CCN
Accessories forCarismaCRC/CRT/CRR/CRS/CCN
GRAFP
PMC
PRC
GRAFG
PCC
FRC
CRC1÷9/CRT1÷7/CRS1÷3
onlyCRS4
CRC1÷9/CRS1÷3
onlyCRS4
Air inlet grid
To be usedwith FRD straight inlet flange.Made of anodized aluminium.
Air inlet grid
To be usedwith FR 90 90° inlet flange.
Made of anodized aluminium.
90° inlet flange
Can be usedtogether with GRAP air inlet grid.
Made of galvanized steel.
Straight outlet flange
Made of galvanized steel.
90° outlet flange
Made of galvanized steelinsulated with polyethylene lining.
Air outlet grid
Double louvre gridto be fitted to the duct,
to the FMD straight outlet flangeor to the FM 90 90° outlet flange.
Made of anodized aluminium.
IV-IO
IV-IO
IV-IO
IV-IO
IV-IO
IV-IO
Model:
Model:
Model:
Model:
Model:
Model:
Version:
Version:
Version:
Version:
Version:
Version:
CRC
CRC
CRC
CRC
CRC
CRC
CRT
CRT
CRT
CRS
CRS
CRS
CRS
CRS
CRS
Accessories forCarismaCRC/CRT/CRR/CRS/CCN
GRAG
GRAP
FR 90
FMD
FM 90
BMA
Accessories
241
Since 1990 Sabiana has been making airhandlingunits,with air flows from 1.000 to 80.000 m3/h. These include standard models,
such as the Ocean and Zeus units, modular solutions
available in a high number of versions that use standard components
and consequently can be delivered with very short lead times,
andcustom made models for individual customer specifications,
using effective configuration and selection software.
The latter units,
called Vulcan Pro, are made
withdoublepanels,35and50mmthick, and
use special aluminium profiles that
ensure the entire inside surface
is completely smooth, without angles
and protrusions, so as to make cleaning easier
and simplify removal of components from the side.
As well as typical solutions that allow greater energy saving,
such as static and rotary heat recovery units and inverter-driven
motors, Sabiana proposes electronicfiltersas alternatives to traditional mechanical bag filters, featuring
a much lower pressure drop and hence low power consumption,
and no need for replacement (they can be returned
to as-new condition by simple cleaning).
All range is compliant with the new
ERP2013Regulation(EU)No.327/2011which requires verylowelectric
consumptionratings in relation
to performances provided.
AirHandlingUnits
243
Technicalcharacteristicsofthemaincomponents:Supportframe: is made of galvanized platesandwichpanels, 24 mm thick, filled
with high-density polyurethane that combine thermal and acoustic insulating features.
Size ENY1, on the other hand, uses
both sandwich panels and self-supporting panels insulated with foam material.
The side panels are easilyremovable, allowing
the position of the air inlet and outlet to be modified, even on site.
Heatrecovery: the heat recovery units are static plate coils that transfer heat between
two flows of air due to the temperature difference. Being static, there are no moving parts.
This is a guarantee of veryhighreliability and operating safety.
The two flows of hot and cold air entering the heat recovery unit are sub-divided
into sections that run between two plates, which carry hot air and cold air alternatively.
These sections are sealed to prevent any possible contamination between the air flows.
The heat is exchanged by the plates that make up the walls of the sections,
withefficiency that reaches values between 50%and75%.To increase the efficiency of the coil,
the surfaces of the plates are fitted with special swirlers.
Condensatecollectiontray: with drain connection on the side (external dia. 14 mm).
Fanassembly: the discharge and intake air fans
are double intake with forward blades. The rotor is directly coupled to the electric motor,
reducing the overall size. Single-phase motor, 230V power supply
with built-in motor protection, three speeds on all models.
Airfilters: pleated cell filters, 48 mm thick, efficiency G3,
with filtering media made from regenerable synthetic material, class F1. The filters
can beremovedfrombelow after having removed the bottom panel of the unit.
Post-Heatingcoil(optional): built on a special galvanised plate frame,
expanded 3/8” copper pipes, aluminium fins with 2.1 mm fin spacing, brass manifolds.
TheEnergy ducted units have been designed
to allow energy savings in the ventilation systems of public
and private environments, such as bars, restaurants, offices, shops, etc.,
byrecoveringtheheatfrom the air discharged
and transferring it to the fresh air introduced into the environment.
The heat exchange between the discharged air
and the fresh air introduced occurs via a static cross-flow coil,
designed to recoverover50%of the heat.
The Energy range features 6sizes suitable
for horizontal installation (1 to 6) and 5sizes for vertical installation (2 to 6),
covering a range of air flows from400to3.500m3/h.In the following pages the horizontal version is shown.
Energy
HeatRecoveryUnitEnergy
245
(*) = Sound pressure measured in an open field at a distance of 1 metre from the fan outlet.NOTE= ENY 1 is only available in horizontal model.
B
A
80
6033
33
80
K
150
WZ
HD
C
X
YW
Z
H
C
D
N
M
Z
C
D
C85
85
ENERGY Technical sPecificaTions
withoutPost-heatingcoil
withPost-heatingcoil
Working static pressure = 50 Pa
Operation at high speed Working static pressure = 50 Pa
3800
64
2800
60
2230
56
51.1
7.8
53.5
8.4
55.3
8.8
3
34.9
35.6
64.7
35,5
1"
51.5
7.9
3600
2500
60
1630
58
1270
48
58.2
9.5
60.8
10.2
62.3
10.6
3
25.5
38.2
42
19
1"
58.4
9.6
2400
2150
62
1690
58
1040
51
51.9
7.9
53.5
8.4
56.6
9.2
3
20.4
36.8
53
22
1"
52.4
8.1
2020
1450
58
1080
53
840
48
54.5
8.6
56.4
9.1
58.0
9.5
3
15.9
41.2
28
14
1"
54.9
8.7
1370
1200
56
940
52
780
49
54.2
8.5
55.6
8.9
56.6
9.2
3
11.7
38.8
36
7
1"
54.8
8.7
1080
620
54
535
52
365
49
54.6
8.6
55.3
8.8
57.1
9.3
3
5.92
37.1
45
6
1"
54.9
8.7
580
m3/h
dB(A)
m3/h
dB(A)
m3/h
dB(A)
%
°C
%
°C
%
°C
N°
kW
°C
Pa
kPa
Ø
%
°C
m3/h
High speed
High speed
Medium speed
Medium speed
Low speed
Low speed
Air flow
Sound pressure (*)
Air flow
Sound pressure (*)
Air flow
Sound pressure (*)
Efficiency (-5°C / 20°C)
Leaving air temperature
Efficiency (-5°C / 20°C)
Leaving air temperature
Efficiency (-5°C / 20°C)
Leaving air temperature
Rows
Emission (air 8°C – water 70/60°C)
Leaving air temperature
Air side pressure drop (coil)
Water side pressure drop
Diameter of threaded male connections
Efficiency (-5°C / 20°C)
Leaving air temperature
Air flow
ENY 6
ENY 6
ENY 6
ENY 6
ENY 6
ENY 1
ENY 1
ENY 1
ENY 1
ENY 1
ENY 2
ENY 2
ENY 2
ENY 2
ENY 2
ENY 3
ENY 3
ENY 3
ENY 3
ENY 3
ENY 4
ENY 4
ENY 4
ENY 4
ENY 4
ENY 5
ENY 5
ENY 5
ENY 5
ENY 5
MODEL
HEAT RECOVERY
POST-HEATING WATER COIL
HEAT RECOVERY
MODEL
Energy
Dimensions and Weight
1030
1480
1480
1480
1750
1750
830
1000
1000
1000
1310
1310
285
420
480
480
540
540
273
316
316
316
470
470
201
204
264
264
325
325
97
208
208
262
262
290
223
232
232
232
298
331
207
268
268
268
345
345
207
244
244
244
321
321
98
161
161
188
188
202
143
200
237
237
268
268
–
110
110
110
110
110
–
585
585
585
740
740
41
85
93
105
140
155
WEIGHT KgA B H C D M N W X Y Z P K
DIMENSIONS mm
123456
SIZE
NOTE= ENY 1 is only available in horizontal model. NOTE= ENY 1 is only available in horizontal model.
247
Energy
Speed switchand switch
for the electrostatic filter
Speed switch
Remote manual speed control.
Switch with 4 positions: - OFF - low speed - medium speed - high speed
Kit with F6 filters(for ENY 2-6 only)
Special F6 filtersin micro-pleated fibreglass.
CIF
COM
SFR
Accessories
Controls
Flanges with spigots
The accessoryis made of a flange to be coupled
to the rectangular inlets and outletsso as to allow the coupling
with round ducts.The kit provides no. 4 flanges per unit.
Electric post-heating coil(for ENY 2–6 only)
To be installed inside the unit,downstream the recovery unit
on the fresh air flow.The coil is provided with
an automatic reset safety thermostatand a manual reset safety thermostat.
Condensate trayfor cooling section
Auxiliaryelectrostatic filter section
Cooling section with 4 row coil(for horizontal units only)
Connecting ductfor cooling section
Made from galvanized steelwith closed cell insulation.
PMR
BER
BCR
SFE
SB4
CCS
Accessories
249
1
2
3
1
2
3
1
2
3
1
2
3
650
1000
1400
1150
1550
2100
1750
2300
3000
2500
3800
5300
45
51
55
50
55
60
53
56
61
55
61
65
SPEED SPEED SPEED SPEEDat
AIR FLOWof m3/h
atAIR FLOW
of m3/h
atAIR FLOW
of m3/h
atAIR FLOW
of m3/hdB(A) dB(A) dB(A) dB(A)
MODEL 1 MODEL 2 MODEL 3 MODEL 4
Technicalcharacteristicsofthemaincomponents:Casing: consists of self-supporting panels
in hot dip galvanized, prepainted steel,
which are completely insulated
with a 20 mm. thick, thermoacustic,
flame retardant lining.
Fansection: for the models 1, 2 and 3
consists of centrifugal fans in galvanized steel with two impellers,
and one directly coupled three speed motor.
Model 4 consists of two motors with external rotor directly coupled to the impeller.
The supply is singlephase230V-50Hz,with permanently installed capacitor, insulation class F.
Coil: is mounted in a galvanized steel carrying frame and
constructed in 3/8” dia expanded copper tubes with aluminium fins with a pitch of 2,1 mm.
The steel headers have tapping for air vent and male connectios.
The coilsaretestedto a pressureof30bars.In normal operation the water temperature should not exceed 95°C
and the maximum working pressure 10 bars. Where a cooling coil is fitted
the coil should always be fitted in a vertical position.
The coil is not suitable for use in corrosive atmosphere or in environments
where aluminium may be subject to corrosion.
Filter: regenerable synthetic filter, 50 mm thick.
The average noise level (soundpressure)is measured in the open air at a distance of one meter from the mouth of the unit.
Noise level
TheOcean modular ducted units are suitable
for heating and cooling small and medium-sized environments.
The compact dimensions of the unit and the modularity
of the basic components simplify installation in small spaces.
Fourbasicmodelsand15versionsare available, both
horizontal and vertical, with air flow-rates ranging from 600 to 5.300 m3/h,
heat outputs from6to68kW, cooling capacities from3to30kW.
As well as the traditional accessories, each unit can be supplied
with theinnovativeCrystallelectronicfilterthat significantly improves indoor air quality.
Ocean
ModularDuctedUnitOcean
251
Heatingandcooling
Combination possibilitiesIn addition to the 12 versions available using standard components
a wide range of furthercombinationscanbeachieved and for each of them
you can choose between the four different types of coil.
Heatingonly
01
07
04
10
02
08
05
11
03
09
06
12
SECTIONWEIGHTS(kg)
Dimensions and Weight
335
415
515
515
300
380
480
480
65
40
40
40
195
300
400
400
600
760
960
960
950
950
950
1500
805
805
805
1355
38
42
45
55
52
62
46
22
24
26
34
30
38
27
18
20
22
28
26
32
23
14
16
18
22
–
–
19
23 28 32 52
A
2 ROWS3 ROWS4 ROWS6 ROWS4 + 2 ROWS6 + 2 ROWSDIRECT EXPANSION
FAN SECTION
COIL
SEC
TION
B C D X Z W
DIMENSIONS mm
1234
MODEL
MODEL 1 2 3 4
FILTERSECTIONSFS
COILSECTIONSBO
FANSECTIONSVE
Ocean
253
20
15
10
5
AV
AIL
AB
LE S
TA
TIC
PR
ES
SU
RE
AV
AIL
AB
LE S
TA
TIC
PR
ES
SU
RE
AV
AIL
AB
LE S
TA
TIC
PR
ES
SU
RE
AV
AIL
AB
LE S
TA
TIC
PR
ES
SU
RE
500 1000 1500 2000
AIR FLOW AIR FLOW
AIR FLOWAIR FLOW
Pa mm H2O
Pa mm H2O
200
150
100
50
25
15
10
5
20
1000 1500 2000
250
150
100
50
200
1500 2000m3/h
m3/sec
2500 3000
25
15
10
5
20
250
150
100
50
200
1500 2500 3500 4500 5500
35
15
10
5
20
0
25
30
350
150
100
50
200
0
250
300
Pa mm H2O
Pa mm H2O
MOD. 2
MOD. 4
MOD. 1
MOD. 3
m3/h
m3/sec
m3/h
m3/sec
m3/h
m3/sec0,2 0,3 0,4 0,5 0,3 0,4 0,5 0,6
0,5 0,6 0,7 0,8 0,5 0,7 0,9 1,1 1,3 1,5
1
2
3
1
2
3
1
2
3
1
2
3
600 700 800 900 1000 1200 1400
900 20001000 1200 1400 1600
1400 1600 1800 2000 2500 3000
5000400030002000
6 7 8 9 10 15 20 30
1510 20 30 40 50 60
1510 20 30 40 50 60
109 15 20 30 40 50
15 20 30 40 50 60 70 80 90
20 30 40 50 100
5 106 7 8 9 15
1510 20 30 40 50
6 107 8 9 11 12
6 107 8 9 11 12
1110 12 13 14 15 16 17 18 19
1510 20 30 40 50 60 70 80
15 20 30 40 50 60
6 107 8 9 15 20 30
Ocean
Performance dataAirsidepressuredropdiagramforinternalcomponents(Pa).Fansectiongraphs.
Performance data
NOTE: fan speed.The curves show the available static pressure of the fan at its various speeds.
The fan section can be used for ventilation or as an air extraction box.The fan performance curve shows the air flow and the available static pressure
for each speed at the mouth of the fan.
MAXIMUMABSORPTION(Ampère)
5,9
3,9
2,9
2,8
2,0
1,5
2,4
1,4
1,0
2,1
1,4
1,0
HIGHMEDIUM
LOW
MODEL
MODEL 1
MODEL 2
MODEL 3
MODEL 4
1 2 3 4
1 2 3
Humidificationsection
Electricbattery
Mixingdamper
Outletairbox
Inletgrid
Carbonfilter
Electrostaticfilter
Cleanairfilter
6rowbatteryoncooling
4rowbatteryoncooling
4rowbatteryonheating
3rowbatteryoncooling
3rowbatteryonheating
2rowbatteryonheating
AIR FLOW (m3/h)
PRESSURE DROP (Pa)
NOTE: to find out the available static pressure of the Ocean modular ducted unityou have to deduct the pressure drop of each component fitted in the unit.
This information can be found in the pressure drop diagram.
255
Total Total Total Total Total TotalSensible Sensible Sensible Sensible Sensible Sensiblem3/h+ 26 + 26+ 30 + 30+ 32 + 32
AIRFLOW
COILROWS
WATER TEMPERATURE 12/17°C
ENTERING AIR TEMPERATURE, DRY BULB °CENTERING AIR TEMPERATURE, DRY BULB °C
WATER TEMPERATURE 7/12°C
1
2
3
4
MODEL
234234234234234234234234234234234234
346346346346346346346346346346346346
6,48,19,19,212,114,011,715,618,410,313,215,014,218,621,617,623,427,615,519,822,519,225,229,325,233,439,425,332,337,134,545,353,142,657,067,9
5,16,57,47,49,811,49,512,615,08,410,712,211,415,117,614,219,022,412,616,118,315,420,523,820,327,232,020,326,230,227,636,743,234,146,155,1
3,24,04,64,56,07,05,87,79,15,16,57,47,09,210,78,611,513,77,79,811,19,512,514,512,316,419,612,315,918,316,822,326,120,728,033,4
7,89,911,211,314,817,114,319,122,412,616,118,317,322,726,321,528,633,718,924,227,523,430,835,630,740,948,230,739,144,941,954,764,351,768,982,1
6,58,39,49,512,414,412,016,018,910,613,515,414,519,122,217,924,028,315,920,323,119,625,930,125,634,340,425,632,937,934,846,054,143,057,869,0
4,55,76,36,58,59,88,210,912,87,39,210,410,013,015,112,316,419,311,013,815,613,617,620,517,623,427,617,422,325,623,831,236,629,439,346,8
9,311,713,313,517,620,417,022,726,815,119,221,920,727,131,425,634,040,222,728,832,928,036,742,536,648,657,436,446,253,149,564,776,061,181,297,1
8,010,111,511,515,217,614,619,523,112,916,618,917,823,327,221,929,434,619,424,928,424,131,636,931,342,049,431,139,845,942,355,765,652,269,983,6
5,97,58,48,5
11,112,810,814,316,89,5
12,113,813,117,119,816,221,525,314,318,220,717,723,226,823,130,736,222,828,933,331,140,547,638,451,060,8
3,23,74,84,35,27,15,26,49,05,65,87,26,77,9
10,38,09,6
13,07,89,8
11,910,212,215,412,515,219,711,815,017,615,520,324,518,524,830,5
1,61,82,22,32,73,12,83,44,52,83,23,43,54,04,94,45,16,43,94,45,45,46,26,66,88,110,05,97,28,48,110,211,310,112,915,3
4,85,67,06,68,010,48,09,813,38,39,010,810,412,315,512,514,919,511,814,517,315,418,322,518,922,929,217,822,025,423,530,135,628,236,844,5
2,93,44,63,94,76,64,65,78,35,16,06,76,07,09,57,08,511,87,08,211,29,311,214,311,213,718,110,713,916,613,917,322,916,521,128,2
5,76,78,17,99,412,29,611,615,69,810,712,712,514,718,314,917,823,014,017,120,218,221,626,422,327,034,321,025,929,627,935,441,633,443,452,1
3,84,55,85,16,28,46,17,610,66,67,88,78,09,412,39,511,415,49,211,614,512,014,518,314,617,923,314,017,820,918,322,428,921,727,535,8
2,22,63,03,23,74,64,04,76,03,84,14,75,15,87,06,47,39,05,66,57,67,48,510,09,511,013,38,29,911,211,414,016,114,217,720,6
1,41,72,02,32,73,12,83,44,52,83,23,43,54,04,94,45,16,43,94,45,45,46,26,66,88,110,05,97,27,68,110,211,010,112,915,3
2,93,53,84,04,65,75,05,97,54,75,16,06,47,38,77,99,111,16,98,19,49,110,512,411,613,516,410,212,313,814,017,219,817,421,625,2
1,92,22,83,03,54,33,84,45,63,54,04,44,85,46,46,06,98,35,25,87,06,97,89,28,910,312,37,79,210,410,612,514,913,416,119,1
3,03,84,14,35,16,35,46,48,25,15,66,56,98,09,58,69,912,27,58,910,39,911,413,612,514,717,911,113,415,115,818,721,518,923,527,4
2,22,63,23,43,94,84,35,06,34,04,55,05,46,17,36,87,89,45,86,87,97,78,910,49,911,513,88,610,411,711,914,116,714,918,021,4
OCEAN Technical sPecificaTions
HEATING EMISSION (kW)
COOLING EMISSION (kW) – Relativ Humidity 55%
600
1000
1400
1000
1550
2100
1500
2100
3000
2400
3800
5300
600
1000
1400
1000
1550
2100
1500
2100
3000
2400
3800
5300
1
2
3
4
MODELm3/h + 20+ 20+ 20 + 10+ 10+ 10 000
AIRFLOW
COILROWS
WATER °C 80/70
AIR °CAIR °CAIR °C
WATER °C 70/60WATER °C 50/45
Ocean
230V ON-OFF VALVE KITfor main and auxiliary coil
Electric heater incorporatinga safety thermostat
The electrical heatersmust be installed downstream
of the fan section.
Humidification section
Deck fill humidificationwith 2 way valve, 230 V 50 Hz supply,
with manual regulationof the water flow rate. The "BRC"drip tray must always be used.
Suspension brackets
Galvanized steel angle bracketsfor ceiling mounting or wall mounting.
Condensate collection tray
Always providedfor 01 to 06 versionsand in combination
with "SUD" humidifying unitand with chilled water coils.
V230
0PA
BEL
SUD
SQS
BRC
Standard unit components
257
Inlet damper
Panel with inlet grid
To be installedon the fan section or on the plenum.
Inlet grid
To be installed on the duct.
Mixing box with two dampers
Top/bottom panel
Inlet/outlet boxwith top or bottom damper
SRA
PGA
GAS
PDS
PSI
PMS
Inlet accessories
Ocean
Inlet box with damper
Inlet box with grid
Section with:pre-filter, electrostatic filter
and active carbon filter
Sectionwith pre-filter
and electrostatic filter
Filter section with damper
Filter section with inlet grid
PAS
PAG
FCA
SFE
FSR
FGR
Inlet accessories
259
Controls
Electronic variable speed drivewith ON-OFF switch
Speed switchand switch
for the electrostatic filter
Manual 3 speed switch.Manual Summer/Winter switch.
Electronic room thermostatfor fan and valve control (ON-OFF).
It allows to controlthe summer/winter cycle
with a centralized and remote switchor with an automatic change-over
fitted on the water pipe.
Manual 3 speed switch,Without thermostatic control.
Speed switch
Remote manual speed control.
Switch with 4 positions: - OFF - low speed - medium speed - high speed
VAR
CIF
TMO-T
MO-3V
COM
Ocean
Outlet accessories
Supply gridwith double louvres
To be installed on the duct.
Supply plenum with spigots
with 3 diffusers (sizes 1-2-3)with 4 diffusers (size 4)
Supply plenumwith double louvres
BMA
PMC
PMB
261
The metal plate used
to make the panels is galvanised and
pre-painted blue on the outside of the panel.
Each unit can beeasilydismantledandreassembledonsite, changing the direction of air flow
according to specific needs. The special construction allows the coil
and the fan assembly to be easily inspected and removed.
Technicalcharacteristicsofthemaincomponents:Casing: made of an extruded aluminium frame with
black fibreglass-reinforced nylon corner joints, and 25mm thick sandwichpanels.The panels are made by joining two sheets: galvanised plate for the inner panel
and galvanised plate painted blue(RAL5012) for the outer panel.
The sandwich panel is filled with a layer of high-density (90 kg/m3) rock wool,
fire resistant class A1 according to DIN 4102 standards.
Fanassembly: is made up of fan, motor and transmission,
fitted on a special mount suspended on rubber anti-vibrating elements,
and with anti-vibrating joints at the fan outlet. The elements making up the assembly
have thefollowingcharacteristics:
Fans: dual intake centrifugal fans with forward blades,
single outlet for sizes 50-80-110, and double outlets for sizes 140-200-250.
The fan shroud and impeller are made from galvanized steel.
Electricmotors: are suitable for a three-phase 50Hz power supply, voltage 400V;
constructional characteristics standardised according to UNEL-MEC form B3.
Index of protection IP 55, insulation class F.
Transmission: is made up of a variable-pitch drive pulley,
a fixed-pitch fan pulley and drive belt. The motor is fitted to a special slide system
used to adjust the tension of the belt.
TheZeus air handling units are suitable for cooling
and heating commercial and industrial environments. They are available
in6horizontalmodels and6verticalmodels, with
air flow from 5.000 to 25.000 m3/h. Heating capacityfrom32to260kW,cooling capacityfrom17to160kW.
The units are made up of a extruded aluminium section bar frame,
anddoublepanelling filled with a 25 mm thick layer
of high-density (90 kg/m3) rock wool insulation that guarantees,
as well as high safety standards in the event of fires (notoxicfumesarereleased), excellent noise absorption and a very high degree
of thermal insulation, minimising dispersions to the outside.
AirHandlingUnitZeus
Zeus
263
SVEZ
SBC2-3-4
SBCF2-3-4
SBF2SX-DXSBF3SX-DXSBF4SX-DXSBF6SX-DX
Dimensions of the main sections
mm
mm
mm
mm
mm
mm
mm
Ø
Ø
Ø
Ø
L
S
H2
H2
H3
H1
H1
2R
3R
4R
6R
1250
740
740
740
350
490
490
1"
1"
1"
1" 1/4
1900
740
740
740
350
490
490
1"
1" 1/4
1" 1/4
1" 1/2
1900
870
870
870
350
590
590
1" 1/4
1" 1/2
1" 1/2
1" 1/2
2560
870
870
870
350
590
590
1" 1/2
1" 1/2
1" 1/2
1" 1/2
2580
1150
1150
1150
400
810
810
1" 1/2
2"
2"
2"
2780
1270
1270
1270
450
810
810
2"
2"
2" 1/2
2" 1/2
Width
Depth
Fan section height
Cooling coil section height
Heating coil section height
Intake plenum section height
Outlet plenum section height
Coil header diameter
Coil header diameter
Coil header diameter
Coil header diameter
MODEL TZ 250TZ 50 TZ 80 TZ 110 TZ 140 TZ 200
Fan section
Heating coil sectionwith 2, 3, 4 rows
Outlet plenum section
Mixing plenum section
Heating coil sectionwith 2, 3, 4 rows+ filter(for horizontalconfiguration only)
Cooling coil sectionwith 2, 3, 4, 6 rows+ filter+ condensate tray(DX = right connections)(SX = left connections)
Coilandfiltersection: is ready to house the coil and filter.
The coil is supported by a frame and is easily removable and reversible, in terms of the side
of the connections, even on site. The coils are with copper pipes and aluminium fins,
and are made using 10mm diameter pipes with 25x22 pitch on sizes 50 - 80 - 110,
and 16mm diameter pipes with 60mm pitch for sizes 140 - 200 - 250.
The water connections are made from steel, with male gas threads.
There are coils with2-3-4rows for heating only operation,
and coils with3-4-6rows for cooling operation.
The dimensions of the coil section depend on the type of operation. Configuration
with horizontal coil for sections for heating only, and configuration
with inclined coil and condensate collection tray for sections for cooling.
The coil is not suitable for use in corrosive atmospheres
or in environments where aluminium
may be subject to corrosion.
Airfilters: the units are fitted
withsyntheticfilters,class G3 according to
EN 779 standard, and class F1
as regards to resistance to fire,
according to DIN 53438 standard.
The filtering layer is designed
with special pleating, 48mm thick,
which reduces the overall
dimensions of the filter
for the same filtering surface.
The filters are made from
individual cells with a metal frame
and galvanized protective mesh.
Thefiltersareremovedfromthesamesideofwaterconnections,so it will be necessary to keepatleast600mmfree on this side,
in order to allow cleaning and replacement of the filters.
Zeus
265
ZEUS Technical sPecificaTions
HEATING EMISSION: Water temperature 70/60°C – Entering air temperature +20°C
COOLING EMISSION: Water temperature 7/12°C – Entering air temp. +27°C – Relative Humidity 50%
4400
7400
10400
14000
20200
24500
4400
7400
10400
14000
20200
24500
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
3
4
6
3
4
6
3
4
6
3
4
6
3
4
6
3
4
6
32,35
42,37
49,77
54,38
71,22
83,66
76,13
99,70
117,12
98,93
129,05
151,28
142,40
186,88
219,08
171,61
226,34
263,21
17,04
20,82
26,68
28,93
35,52
45,47
39,98
50,46
63,85
54,40
72,10
92,50
78,78
104,41
133,95
101,58
126,45
160,94
41,9
48,6
53,6
41,9
48,6
53,6
41,9
48,6
53,6
41,2
47,5
52,7
41,1
47,5
52,7
41,3
47,7
52,8
14,00
16,40
19,36
23,77
27,98
33,00
32,85
39,36
46,01
41,60
51,10
62,70
60,24
74,00
90,80
75,50
89,62
109,09
2828
3704
4350
4753
6226
7312
6655
8716
10236
8688
11317
13266
12506
16389
19211
15071
19849
23082
2931
3581
2656
4976
6109
7821
6876
8680
10982
9333
12364
15830
13516
17913
22982
17428
21695
27612
TZ 50
TZ 50
TZ 80
TZ 80
TZ 110
TZ 110
TZ 140
TZ 140
TZ 200
TZ 200
TZ 250
TZ 250
MODEL
MODEL
m3/h
m3/h
kW
kW
°C
kW
l/h
l/h
AIR FLOW
AIR FLOW
ROWS
ROWS
THERMALPOWER
TOTALTHERMAL POWER
LEAVING AIRTEMPERATURE
SENSIBLETHERMAL POWER
WATER FLOW
WATER FLOW
Zeus
2
3
4
6
2
3
4
6
2
3
4
6
2
3
4
6
2
3
4
6
2
3
4
6
53
75
92
118
169
190
112
155
187
248
379
522
66
69
72
–
91
93
99
–
107
110
118
–
152
157
172
–
193
198
220
–
225
231
257
–
102
105
109
117
139
143
149
161
174
177
185
201
236
241
256
286
324
329
351
388
376
382
408
459
3,2
4,6
6,2
8,2
5,3
7,7
10,2
14,8
7,2
10,7
14,3
20,9
10,2
15,3
20,4
30,4
15,3
22,5
29,4
44,5
18,4
27,5
37,5
55,6
TZ 50
TZ 80
TZ 110
TZ 140
TZ 200
TZ 250
MODELkgkgkgkgliters
ROWS PLENUMSECTION
FANSECTION
HEATINGCOIL SECTION
SBC
COOLINGCOIL SECTION
SBF
WATERCONTENT
Weight and water content
FAN SECTIONTechnical sPecificaTions
AT 12/12
S
1,1
4
2,6
AT 15/15
S
2,2
4
4,8
AT 18/18
S
3,0
4
6,6
AT 15/15
D
4,0
4
8,3
AT 18/18
D
5,5
4
11,0
AT 18/18G2C
D
7,5
4
400 V
14,6
690 V
9
400 V
0 ÷ 191 0 ÷ 256 0 ÷ 298 0 ÷ 202 0 ÷ 164 0 ÷ 166
108 ÷ 238 64 ÷ 303 87 ÷ 345 35 ÷ 257 32 ÷ 220 0 ÷ 221
kW
3 ~ 50Hz
A
Pa
Pa
Type of fan
Single / Double outlet
Power consumption
Poles
Tension
Nominal current
Available static pressureLow / High Model (2)
Available static pressureLow / High Model (1)
MODEL TZ 50 TZ 80 TZ 110 TZ 140 TZ 200 TZ 250
Type (1)= The values refer to a configuration with intake grill, filter, 6-row cooling coil, 2-row heating coil, fan section.Type (2)= The values refer to a configuration with filter, 4-row cooling coil, fan section.
267
Zeus
Intake galvanized damperwith intake grid
Intake galvanized damper
Anodised aluminiumintake grid
SRAGO
SRASO
GASO
HorizontalSections accessories
Intake galvanized damperwith intake grid
Intake galvanized damper
Anodised aluminiumintake grid
SRAGV
SRASV
GASV
VerticalSections accessories
Control panelQ
Supply plenumwith adjustable diffusers
1 way plenum
(for horizontal versions)
Outlet plenum with double rowof aluminium fins.
3 way plenum
(for vertical versions)
Outlet plenum with double rowof aluminium fins.
1 way plenum
(for vertical versions)
Outlet plenum with double rowof aluminium fins.
PMU
PMB1VO
PMB3VV
PMB1VV
OutletPlenum accessories
Controls
Mixing boxwith intake grid
and galvanized damper
(for horizontal versions)
Mixing boxwith intake grid
and galvanized damper
(for vertical versions)
Mixing boxwith two galvanized dampers
and intake grid
(for horizontal versions)
Mixing boxwith two galvanized dampers
and intake grid
(for vertical versions)
Mixing boxwith two galvanized dampers
(for horizontal versions)
Mixing boxwith two galvanized dampers
(for vertical versions)
PGSO
PGSV
PDSGO
PDSGV
PDSO
PDSV
InletPlenum accessories
269
The basic configuration is made of sandwich panels
intwonominalthicknesses,35and50mm, with the outside surface
made from pre-painted galvanised steel and the inside surface from galvanised steel,
with high density polyurethane foam thermal insulation in between, making the unit
suitable for indoor and outdoor installation.
The variants of the basic configuration include stainless steel
or Peraluman inside panels, Peraluman outside panels and mineral wool insulation
so as to guarantee maximum safety in the event of fires (notoxicgasesarereleased) with effective sound absorption.
The units are available in 23sizes,from1.000to80.000m3/h.
TheVulcanPro air handling units are built
in compliance with the European standards and directives,
and are designed to satisfy all design requirements
for air conditioning systems in which the reduction of noise levels,
high air quality and minimum energy consumption
are fundamental aspects in assessing the quality of the installation.
The main defining feature of this new series
concerns thespecialdesign of the aluminium frame
that make up the structure, aimed at creating perfectly smooth inside walls,
withoutgapsorprotrusions, so as to simplify
cleaning and allow access to the components from the side.
AirHandlingUnitVulcanPro
VulcanPro
271
A AL
AA
HB
•Acorrespondstothethicknessofthepanels
•Base:B=80/120mm
•Uptosize250-175thepanels
canbeselectedintwothicknesses,35 and 50 mm
•Fromsize250-200onthepanelsare50 mm thick only
Thelengthsofthesectionsandthecorrespondingweightsmustbeobtained
fromtheselectionsoftware.
Front dimensions
650,0
802,5
650,0
802,5
955,0
1107,5
1107,5
1260,0
1107,5
1260,0
1565,0
1565,0
1565,0
1870,0
1870,0
2175,0
2480,0
2480,0
2785,0
3090,0
3395,0
4005,0
4005,0
457,5
457,5
610,0
610,0
610,0
610,0
762,5
762,5
915,0
915,0
915,0
1067,5
1220,0
1220,0
1525,0
1525,0
1525,0
1830,0
1830,0
1830,0
2135,0
2135,0
2440,0
MEASUREMENT (mm)
L H
100 - 75 125 - 75 100 - 100 125 - 100 150 - 100 175 - 100 175 - 125 200 - 125 175 - 150 200 - 150 250 - 150 250 - 175 250 - 200 300 - 200 300 - 250 350 - 250 400 - 250 400 - 300 450 - 300 500 - 300 550 - 350 650 - 350 650 - 400
SIZE VulcanPro
dB 11,0 dB 9,0 dB 11,0 dB 12,0 dB 15,0 dB 27,0 dB 34,0
1252505001K2K4K8K
Casing strengthCasing air leakage at -400 PaCasing air leakage at +700 Pa
Thermal transmittanceFilter bypass leakage
Thermal bridging factor
D1L1L1F9T3
TB3
SpecificationsofthecasingaccordingtoUNI-EN1886Standard
SoundAttenuation
ThecasingoftheVulcanProunitsismadeupasfollows:
Supportingframe madefromextrudedaluminiumalloysectionbars,naturalcolour.
Joints madefromreinforcednylon(for35mmthick)andcastaluminium(for50mmthick).
Sandwichpanels available in two nominal thicknesses, 35 and 50 mm,
made from the following materials:
•standardouter:pre-paintedgalvanisedsteel,lightgreycolour.
inner:galvanisedsteel.
insulation:injectedpolyurethane,density45Kg/m3.
•uponrequestouter:AISI304stainlesssteel-Peraluman.
inner:pre-paintedgalvanisedsteel
-AISI304stainlesssteel-
Peraluman.
insulation:mineralwool,
density90Kg/m3.
•assembly usinggalvanisedsteelself-threadingscrews,
withNeopreneself-adhesivegaskets
insertedbetweenthesectionsandthepanels.
Thepanelswithmineralwoolinsulationareassembledusingscrewsinbushes.
Accessdoors: same construction as the panels, fitted with reinforced hinges
and locking device, complete with sealing gasket, safety switch for fan sections and,
upon request, fitted with inspection window. For sections with high inside pressure
(e.g. fan sections with plug fans or with absolute filters), the doors are completely removable
and fixed with bars and screw knobs.
Baseframe: made with galvanised steel“C”bars,fitted with eyebolts for handling, arranged around the perimeter of each section.
Frequency(Hz)35mmand50mmthickpanels
withpolyurethane
273
3 2.5
10090807060
50
40
30
25
20
15
10987
6
5
4
3
2
12
Air speed (m/sec)
Air
flow
-rat
e (m
3 /h
x 10
00)
100-75
125-75
125-100
200-125
175-100
200-150
250-175
300-200
350-250
400-300
500-300
650-350
100-100
150-100
175-125
175-150
250-150
250-200
300-250
400-250
450-300
550-350
650-400
Outdoormonoblockunitwithprotectivecover,rainprotectiongrillwithbirdguards,louvre,G4+F7pre-filters,treatmentsectionwithpre-heating,coolinganddehumidificationcoil,
steamandpost-heatingcoil.Motorfansectionwithplug-fanunitandfinalfiltrationwithSABIANACrystallelectricalfilters.
Modularunitsinthreesectionswithmixingchamber,G4+F9pre-filters,treatmentsectionwithpre-heating,coolinganddehumidificationcoil,honeycombpackhumidifierswithrecirculationandpost-heatingcoil.
Motor-fansectionwithcentrifugaltransmissionventilatorandH13absolutefiltration.
Unitswithejection-recirculationsectionandexteriorfreshairintakewithG4filter,heatrecoverycoilandfan-motorplug-fanassembly.TreatmentsectionwithG4+F7pre-filters,heatrecoverycoil,
pre-heatingcoilandcoolingcoilanddehumidificationwithdropletseparator.Outletfansectionwithplug-fanassemblyandSABIANACrystalelectricalfilters.
Theinletandoutletoftheunitisequippedwithalouvrewithon-offactionforinteractionwiththetreatedenvironmentandgermicidallampsonthesurfacesofthecoilsandmechanicalfilters.
DoubledeckunitwithsectionequippedwithstaticheatrecoveryunitwithcrossflowsandwithrecirculationlouvreandG4pre-filters.TreatmentsectionwithF8rigidbagfilters,
pre-heating,coolinganddehumidificationcoil,humidifierwithnozzlesandrecirculationpumpinadualchamberwithairdirector/splashguardanddropletseparatorandpost-heatingcoil.
Outletfansectionwithcentrifugaltransmissionfanandsilencer.OverdeckairintakesectionwithG4filter,silencerandcentrifugaltransmissionfan.
DoubledeckunitwithsectionequippedwithG4+F7pre-filtersandrotaryheatrecoveryunit,treatmentsectionwithpreheatingcoilandcoolinganddehumidificationcoil,
honeycombpackhumidifierwithexteriorrecirculationpumpkit.Motor-fanoutletsectionwithpost-heatingelectricalcoil,plug-fanunitandfinalfiltrationwithSABIANACrystallelectricalfilters.
OverdeckairintakesectionwithG4filterandmotor-fanplug-fanunit.
Examples of unit compositions
TheVulcanPro air handling units are available
in 23sizes that can be easily selected using the diagram shown below,
based on the air speed through the coil.
Tosimplifyselection, it must be stressed
that in both cooling/dehumidification and heating/humidification,
the correct air speed is essential toavoidentrainingdrops.
It is therefore recommended to use a dropletseparatorfor humidification and dehumidification when the air speed exceeds 2.5 m/sec.
In humidification and cooling/dehumidification,
the maximum speed of 2.8 m/sec should notbeexceeded.
Range
VulcanPro
275
1) Air outlet grid
2) Electronic filter lock
3) High voltage cable
4) Ionic field
5) Duct
6) “Crystall”electronic filter
TheCrystallDuctSystem is an innovative
filtering system to be mounted on air outlets or inside ducting.
It is made up of3elements: a) patented electronic plate filter (“Femec” type)
b) electronic control and power board
c) high voltage flexible connection cable
The system has been designed
to reduce the indoors diffusion of various types of pollutants
found in the ducting of air conditioning systems. As a result, it is ideal
for various types of environments, such as schools, hospitals
and rest homes (corridors, waiting rooms, wards), doctors’ surgeries,
hotels and anywhere indoor air quality needs to be improved.
AdvantagesoftheCrystallDuctSystem:• Installation possible on existing systems
• Low impact on the thermal and aeraulic equilibrium of the installation
• Reduced pressure drop even when the filter is dirty
• Significant bactericide action on biological pollutants
• No cost for replacing the filters (the filters are totally regenerable by simply washing them)
• Very low additional energy costs
• Simple and fast maintenance
• No system downtime for the maintenance of the filter
• Remote power supply that can supply multiple filtering units at the same time
TestsandCertification: the Crystall Duct System has been the subject of numerous
efficiency and effectiveness tests to assess the functions and performance of the systems
in real conditions. At the Turin Polytechnic Department of Energy, efficiency and pressure
drop tests were performed using the EN 779 international filter classification standards,
where applicable. The University of Ancona carried out over 180 laboratory tests on micro-
biological substances (total airborne microbiological load), including bacteria, mould, fungi,
etc., which confirmed, through the statistical analysis of the data taken from the Fischer test,
the effectiveness of the Crystall electronic filter in reducing the bacterial load.
Other tests have been carried out in the SABIANA laboratories on the flow-rate,
pressure drop, electrical safety and instrumental efficiency of the filtration process on micro-
particles by numerically counting the most common particle size categories in various rooms.
The particles monitored had the diameters specified by the WHO (World Health Organization)
and the EPA (Environmental Protection Agency) as being the most harmful to our health
(<2.5 micron PM 2.5), with volumetric counts (number/m3) being performed in a common
living environment, using a laser particle counter (LPC).
1) Duct
2) Air outlet grid
3) Shielded high voltage cable
4) Power supply and control box
5) Air outlet
Contructionfeatures: for more details, see “Crystall Flex System”.
CrystallDuctSystem
1 2 3
45
1 2 3
45
1 2 3
45
ElectronicFilterCrystallDuctSystem
277
This type of equipment was specifically created to be able
to be insertedontheductupstream from the air handling
units. The structure is in galvanised, prepainted plate and is
ready for coupling to flanged ducts. Inside there is a mechanical
filter section with a depth of 48mm and an electronic filter
section. The unit has a closing panel that allows easy access
for mounting and maintenance operations.
Itcanbeextendedto90mmforconnectorsordiffuserswithlouvres40
Dimensions
Dimensions
Dimensions
150 x 225
150 x 300
150 x 375
225 x 225
225 x 375
225 x 450
225 x 525
300 x 300
300 x 375
300 x 450
300 x 525
300 x 600
375 x 375
375 x 450
375 x 600
150 x 300
150 x 400
150 x 500
150 x 600
200 x 400
200 x 500
200 x 600
200 x 800
300 x 500
300 x 600
300 x 800
400 x 600
400 x 800
400 x 1000
0,015
0,023
0,030
0,025
0,050
0,062
0,075
0,045
0,060
0,075
0,090
0,105
0,080
0,100
0,140
0,023
0,033
0,043
0,053
0,043
0,057
0,070
0,096
0,085
0,105
0,145
0,168
0,232
0,296
0,033
0,045
0,056
0,050
0,084
0,101
0,118
0,090
0,112
0,135
0,158
0,180
0,141
0,169
0,225
0,045
0,060
0,075
0,090
0,080
0,100
0,120
0,160
0,150
0,180
0,240
0,240
0,320
0,400
148
148
148
223
223
223
223
298
298
298
298
298
373
373
373
148,5
148,5
148,5
148,5
198,5
198,5
198,5
198,5
298,5
298,5
298,5
398,5
398,5
398,5
223
298
373
223
373
448
523
298
373
448
523
598
373
448
598
298,5
398,5
498,5
598,5
398,5
498,5
598,5
798,5
498,5
598,5
798,5
598,5
798,5
998,5
NOMINALDIMENSIONS
H X B
NOMINALDIMENSIONS
H X B
FILTERSURFACE
Sf
FILTERSURFACE
Sf
NOMINALSECTION
Sn
NOMINALSECTION
Sn
mm
mm
L
L
A
A
mm
mm
mm
mm
mq
mq
mq
mq
CDS.ICDS.ICDS.ICDS.ICDS.ICDS.ICDS.ICDS.ICDS.ICDS.ICDS.ICDS.ICDS.ICDS.ICDS.I
CDS.ECDS.ECDS.ECDS.ECDS.ECDS.ECDS.ECDS.ECDS.ECDS.ECDS.ECDS.ECDS.ECDS.E
MODEL
MODEL
The CDS-I internal duct filter is equipped with a
smooth containment frame to allow insertion in the terminal
duct. It can be mounted using screws or rivets which must
be inserted from inside.
TheCDS-Eexternalductfilter is equipped with a
perimeter flange that allows to be mounted on standard
openings currently on the market. Mounting is done using
the same flange that can be screwed or riveted to the outer wall of the duct. The design of
the structure takes into account the fact that the air distribution terminals may or may not
be equipped with a damper. The filter collar, in fact, is
of the telescopic type and therefore the depth can be
varied during installation.
600 x 300
600 x 600
0,207
0,414
0,18
0,36
380
680
415
715
NOMINALDIMENSIONS
H X B
FILTERSURFACE
Sf
NOMINALSECTION
Sn
mm
A D
mm mm mqmq
CDS.CCDS.C
MODEL
"CDS-I" filter"CDS-E" filter
"CDS-C" filter
CrystallDuctSystem
279
The operating principle of these filters is based on applying a high potential difference
between discharge and collecting electrodes, so as to create a strong electric field that
reaches maximum intensity near the discharge electrodes.
The air around the surface of the discharge electrodes, which contains particle pollution,
is thus ionised.
The resulting effect is called acoronadischarge, as the ions tend to move from the
corona or ring around the discharge electrodes towards the collecting electrodes.
During such movement, the ions generated collide with the particles of pollution suspended
in the air, which become positively charged (each particle can be charged by many different
ions, reaching very high electric charges).
The positively charged particles (+) are then drawn towards the collecting electrodes (-),where they are captured.
In designing and developing theSABIANACrystallmodularelectrostaticfilter(“FEMEC”), all the positive features of classic plate electrostatic precipitators have been
retained. This new solution features two separate and distinct sections, each with different
construction technology and with its own specific purpose.
The first section consists of electrodes and insulating parts, called the“activeelementsection”, while the second, subject to “loading” and consequently frequent handling for
cleaning, is called the “passiveelementsection”.The active components in the first section are secured to the holding structure, containing the
actual filter that, not requiring regular maintenance and therefore handling, can be built to
guarantee reliability and safety at low cost, as it does not contain special, delicate and expensive
materials (insulators etc.).
The second section with passive
elements (collector) is made from
aluminium plates and is designed
to be built in various different sizes,
so as to satisfy a wide variety of
needs in terms of construction and
overall dimensions.
This second section is in turn
divided into two parts, a grounded
passive part designed to capture
the dirt, and another active part,
being subjected to the voltage
induced by the polarising electrode.
Operating principle
SABIANA Crystallelectrostatic filter FEMEC (patented)
Electrostatic filtration is currently considered one of the most
advanced systems for capturing particles in an air stream, capable of ensuring
high and lasting efficiency and with major benefits in terms of quality-price
ratio, considering their longer life compared to any other type of filter.
Cost analysis should also take into consideration the very low pressure drop
rate and reduced running costs, thankstothesimplewashingof the filters with water and detergent.
Their high filtration efficiency combines with considerable bacterial
disinfectionandviralinactivation,bringingthetreatedairtothehighest
qualitylevelsdefinedbytherelevantstandards.
VulcanProw
ithCrystall
POLLUTED AIR INLET
CLEAN AIR OUTLET
STAGE
2
STAGE
1
Ionisedparticle collectorin inducedelectric field
Positivepolarisationof particles
Collection surface
Inducted anode
Polarising electrode
Ionising field
Mechanical pre-filter
AirHandlingUnitswithCrystallElectrostaticFiltersforAirQualityandEnergySavings
VulcanPro
281
VulcanProw
ithCrystall
This(patented)systemallowselectricfieldstobecreatedontheopposingsurfaceswithoutrequiringadditionalpowersupplies,
andalsomakeseachpartofthecollectorindependentfromtheothers,meaningshortaccidentalcircuitsinonesectiondonotaffectoperationofthefilterasawhole.
All electrostatic filters / active electronic
plate filters have the advantage
of producing a limited amount of ozone.
TheSABIANACrystallelectrostaticfilterisratedasclassD-PE,certified
byTurinPolytechnicEnergyDepartment.
The figure showsRodac plates
with specific culture media following exposure
to the air delivered into the environment
by the ventilation system being tested.
On the right is the culture plate
with theelectrostaticfilter operating,
on the left the plate when the system is off.
LIVE/DEAD=2.7
INAIR
(EPI,propidiumiodide-SybrgreenI)
Confirming the importance of this topic, we can quote for example
the “LombardyRegionLocalHygieneRegulations”, published in the official Regional Bulletin
on 25/10/89 (also taken on by other Regions and Municipalities), specifically
paragraph 3.4.47=Air-conditioning:systemfeatures where, in point c), the text reads:
Airpuritymustbeguaranteedbyapplyingsuitablemeasures(filtrationanddisinfectionwherenecessary)aimedatensuringthattheairinsidetheenvironment
doesnotcontainparticlesexceeding50micronsinsizeandthereisnopossibilityofinfectiousdiseasesbeingtransmittedviatheair-conditioningsystem.
Microscope measurement
showed 85%efficiencyinbacteriaremoval(EPI, Acridine Orange)
LIVE/DEAD=1.4
ONSURFACE
E.COLI
Electrostatic filters have considerable germicidal potential due to their ionising action and the
consequent production of small amounts of ozone that, combined with UV radiation, stop the
proliferation of biological substances and contaminants on the surfaces of the passing dust,
oxidising and inactivating them.
It worth stressing theinactivation of these trapped pollutants by the system, as the same
cannot be guaranteed by normal mechanical filtering, even high efficiency filters, meaning
these latter systems accumulate live contaminants that form colonies and require the personnel
performing maintenance and replacing the filters to adopt special precautions for their own
protection and to protect the surrounding environment.
The following tables list the main pathogens, such as: viruses, pollen, mites and fungi, indicating
the diseases and harm these can cause to the organism, their origin, shape and average
diameter in microns.
Based on their dimensions, in fact, it can be easily seen thatallpollen,mitesandfungilistedinthetablescanbecaptured,inactivatedandtrappedbyelectrostaticfilters, in relation to their efficiency.
Cocerningviruses even though these are very small in size, they can still be intercepted,
trapped andrenderedinactive, as they are always connected to and carried by larger
particles.
One important experiment, until now the only one of its type conducted, was commissioned
by Sabiana and carried out by the University of Ancona, Department of Physics and Materials
Engineering and Territory, for the purpose of evaluating the bactericidal action of our
electrostaticfilter on biological pollutants.
A detailed description of the experiment and related certification are available upon request,
however the results can be summarised as follows:
1)Electrostaticfilterefficiencyinremovingbacteria
2)Electrostaticfiltereffectonbacterialvitality
3)Electrostaticfiltereffectonbacterialgrowth
Germicidal effect
OFF
OFF
ONON
ON
OFF
OFF ON
283
VulcanProw
ithCrystall
TheSABIANACrystallelectrostaticfilter features the same modularity in terms
of sizing as mechanical filters, and consequently the latter can be used both as pre-filters
(G1-4) and as post-filters (absolute H10-14).
On the first 14 sizes of theVulcanPro air handling units, the electrostatic filters can be
removedfromtheside on slides, with maximum side dimensions of 600 mm, while
on the next 9 sizes they can be removedfromthefront, on the air supply side.
Air handling always requires high amounts of energy, mainly due to the pressure drop of the
distribution ducts and the filters.
While for the ducting it is hard to imagine where considerable improvements can be made
in the short term, as regards filters, on the other hand, energy consumption can be reduced
quite significantly.
Staying within the scope of this report, which only concerns filtration, it can be seen how
pressure drop is directly proportional to the efficiency of the filters installed, efficiency that
depends on desired indoor air quality required and the quality of the incoming outside air,
as well as naturally on how loaded the filters are.
It should be remembered that indoor air quality standards are becoming stricter all the time,
while outside air quality is at alarming levels in terms of dust and harmful gas concentrations,
especially in highly urbanised and industrial areas.
Consequently, there are two seemingly irreconcilable needs: the demand for better filtration
combined with the need to minimise system energy consumption.
As we have seen previously, electrostatic filters represent a very good first response to
reconciling these two needs, as they feature high efficiency and very low pressure drop,
the latter remaining stable over filter operating life.
During operation the increased pressure drop of mechanical filters causes an increase in power
consumption by fan motors, needed to ensure design air flow, or alternatively a progressive
reduction in air flow when the system does not feature any form of automatic compensation.
In electrostatic filters, the particulate in suspension is carried by the air stream until binding
to the collector plates set out in the same direction as air flow; in this way, by ensuring suitable
spacing between plates, even large particle deposits provide little resistance to the air stream,
meaning very low pressure drop.
Thanks to this property, electrostatic filters feature a virtually constant pressure drop throughout
their normal operating life, which ends when the thickness of the deposits begins to affect the
electric field, rather than prevent the flow of air as occurs in mechanical filters.
To determine the difference in energy consumption in percentage terms between mechanical
filters and electrostatic filters, a module made up of two standard rigid bag filters can be used
as a reference, with design dimensions of600x1200x300mm, compared against an
electrostatic filter cell measuring600x1200x100mm, with air flow at three reference
frontal velocities, 2,2.5 and 3m/s, pressure drop values based on the difference between
initial, at the various air flows, and final pressure of 300 Pa defined by legislation.
Where:E= energy consumption in kW per hour
Q= air flow in m3/s
P= average pressure drop in Pa
Energy consumption can be calculated using the following expression: QxPE=----- 1000
Modular sizing Energy savings
Diagramoftheelectrostaticfilterwithremovalfromtheside,placedupstreamanddownstreamofthefan.
Diagramoftheelectrostaticfilterwithremovalfromthefront,placedupstreamanddownstreamofthefan.
Electrostaticfilterandabsolutepost-filterremovablefromthefront,throughtheinspectiondoor.
Spaceoccupiedbytheelectrostaticfilterwithmechanicalpre-filterandremovalfromtheside.
MECH.PRE-FILTERS
INSPECTIONDOOR
AWGCABLE POWERCABLECONDUIT
285
ENERGYCONSUMPTIONRef.:rigidbagfiltermodule600x1200x300mm
electrostaticfiltermodule,nom.dim.600x1200x100mm
As an example, a table is shown below comparing annual power consumption
between different types of filters, based on two hypothetical extremes of operating time:
• 12 hours/day for 210 days/year (e.g. offices) • 24 hours/day for 365 days/year (e.g. hospitals)
The above table highlights the advantages, from a maintenance point of view, of using
“Crystallelectrostaticfilters” compared to normal mechanical filters, which can
be summarised as follows:
• Electrostaticfilters, being made from aluminium plates, do not require replacement,
rather they can simply be washed and repositioned in the special compartment, an operation
that can even be carried out by non-specialist personnel.
• This is a significant advantage, as mechanical filters, being classified as special waste,
require costly disposal procedures that must be carried out by specialist personnel, using
special protection equipment to protect both themselves personally and the surrounding
environment. Withelectrostaticfilters, maintenance is safe as the bacterial charge
on the filter is inactivated by the electrostatic field generated.
• Even G2 metallic pre-filters, rated to trap coarse dust, can be regenerated by simple
washing.
3784.323924.484064.641110.772960.883066.003188.64788.40
2260.082330.162400.24567.65
1088.641128.961169.28319.54851.76882.00917.28226.80650.16370.32690.48163.29
F7 mechanical filter F8 mechanical filter F9 mechanical filterB.PE electrostatic filter F7 mechanical filter F8 mechanical filter F9 mechanical filterB.PE electrostatic filter F7 mechanical filter F8 mechanical filter F9 mechanical filterB.PE electrostatic filter
2.16
1.80
1.44
3
2.5
2
VulcanProw
ithCrystall
For each different efficiency, energy consumption will be as follows:
Comparing the above results,
it can be concluded that "electrostatic filters"consumemuchlesspowerthan mechanical filters, as shown below in percentage terms:
(*) = filter electronic control device power consumption = 0.5 watt x dm2 of frontal surface
MECHANICALFILTERS
COMPARISONBETWEENDIFFERENTFILTRATIONSYSTEMS
SABIANA“CRYSTALL”ELECTROSTATICFILTERS
2.16
1.80
1.44
2.16
1.80
1.44
464
364
274
-72,7%
-75,3%
-76,3%
448
350
266
-71,7%
-74,3%
-75,6%
432
338
258
-70,6%
-73,4%
-74,9%
90.8 + 36 (*) = 126.8
54.0 + 36 (*) = 90.0
28.8 + 36 (*) = 64.8
AIR FLOW
AIR FLOW
AIR FLOW
ENERGY CONSUMPTION in Watt/h for FILTER CLASS
FILTER TYPEand CLASSIFICATION
OPERATION12 hours a day210 days/year
OPERATION24 hours a day365 days/year
COMPARED to FILTER CLASS
ENERGY CONSUMPTION in Watt/h
m3/s
m3/s
m3/s
m/s
m/s
m/s
m/s
F9
kW/h
F9
F8
kW/h
F8
F7
F7
3
2.5
2
3
2.5
2
3
2.5
2
FRONTAL VELOCITY
Type
Class
Standard
Average efficiency (%)
Initial efficiency (%)
Final pressure drop
Pressure drop for replacement
Regenerable
Disposal
Maintenance costs
Total bacterial charge risk
Filter with mechanical media
F7
80/90
>35
450 Pa
300 Pa
Not possible
Special waste
Replacement and disposal
High
EN 779
F8
90/95
>55
F9
>95
>70
Electrostatic filter
Class D / B
UNI 11254
80/90
>80/90
Max 30 Pa
Not significant
Fully
No disposal
Washing
Very limited (Biocidal action)
Clean outside air
ODA1
EN 13779
–
–
–
–
–
–
Adequate filtration
According to quality
FRONTAL VELOCITY
FRONTAL VELOCITY
FRONTAL VELOCITY
Electrostatic filters certainly ensure high real system efficiency with
considerable energy savings; in addition, as the difference in pressure drop between clean
filter and loaded filter is virtually negligible, no special devices are required to compensate
for pressure drop so as to maintain variation in air flow within the allowed limits, thus simplifying
both system installation and management.
The economic comparison must also consider this feature and there will always be lower fan
power consumption compared to mechanical filters as these have to be rated at the maximum
pressure drop allowed, which is simulated, when the filters are clean, by the automatic
compensation control.
The following table summarised the concepts described above, comparing each aspect
for different filtration systems, and specifically highlighting the difference in initial efficiency
for clean filters:
Conclusions
Sabiana uses modern
electronic instruments to verify the chemical
composition of all materials received, thus totally
guaranteeing that the stainless steel used and declared
complies with the required technical specifications.
The production processes are completely automatedand allow the use of some of the thickest materials
available on the market, significantly extending product life
and resistance to corrosion by acid flue gas.
A highly advanced selectionsoftware can be used to check
suitability of the chosen diameter for the type of installation.
Eight product lines, including three in plastic,
allow the best choice to be made based on
the type of boiler and the flue installation site.
287
Since 1985 Sabiana has been selling
- and since 1997 manufacturing -stainlesssteelflues, single or
double wall versions, for discharging flue gas from boilers.
Considering the intended use of these flues, the relevant
European directive on Construction Products requires
product certification by a notified body, with annual audits of the design,
engineering, manufacturing and storage processes.
Sabiana uses the services of the prestigious and demanding
IMQItalianOrganisation, which has been checking and testing
product quality since the Directive came into force.
Flues
289
Longitudinal microplasma welding is used on both
the inner and outer wall on each element,
while the 90° T sections, flue gas monitoring
and inspection module are made using
the deep drawing process, thus avoiding
welding. All the non-insulated elements are
made from AISI 304 stainless steel (aluminium
adjustable flashing and storm collar).
In addition, the use of an innovative fastening system means
that the thermal bridge between the inner and outer wall is reduced to the minimum.
The InoxSabiana 25 series includes 8differentinsidediameters(from100to350mm) and a complete series of accessories for solving
all problems relating to the discharge of the flue gas from heat generators.
Mainconstructionalcharacteristics:• AISI316Lstainlesssteelinnerwall (austenitic stainless steel 18/10 with low carbon content, grade UNI X 2, CrNiMo 1712).
Thickness: 0,5 mm.
Properties: high resistance to intergranular corrosion and particularly aggressive products.
• AISI304stainlesssteelouterwall (austenitic stainless steel 18/10, grade UNI X 5, CrNi 1810).
Thickness: 0,5 mm.
Properties: good resistance to corrosion in air and water.
Upon request, copper outer wall is available.
• Rockwoolinsulation with basaltic composition, minimum density 90 kg/m3, thickness 25 mm.
Properties: the rock wool used is chemically neutral, is not hydrophilic nor hygroscopic, nor
has a capillary action. It is free of asbestos and crystalline silica, has low conductivity values.
The rock fibres making up the insulation can withstand temperatures exceeding 1000°C.
The insulation is classified as incombustible by the French standard MO-CSTB n°92.34624-3.
• Longitudinalmicroplasmawelding on both the inner and outer wall, in each
element.
• All the non-insulated elements are made from AISI 304 stainless steel (storm collar and
adjustable flashing are made in aluminium). The screws supplied are in stainless steel.
• Minimumthermalbridge between the inner and outer pipe, due to the adoption
of an innovative fastening system.
• Special design of the inner wall so as to allow free expansion according to the flue gas
temperature.
• Insulated individual cardboard packaging for each element.
• Wall brackets and supports with adjustable lengths.
The InoxSabiana25 series is the result of an innovative
constructional design aimed at achieving a high quality product, versatility
and ease of assembly. The choice of the materials, the use of
the latest construction techniques, the care paid to every accessory,
the conformity with the European EN 1856-1:2009 standard,
the continuous checks on the products and the production process,
and the quality mark issued by the prestigiousItalianInstituteIMQ,guarantee the absolute reliability of the Sabiana flues.
The inner wall is made fromAISI316L stainless steel,
0.5 mm thick, while the outer wall is made fromAISI304 stainless steel,
0.5 mm thick, or alternativelycopper, 0.6 mm thick. The insulation
is rock wool, with a minimum density of 90 kg/m3, 25 mm thick.
StainlessSteelDoubleWallFluesInoxSabiana25
InoxSabiana25
291
The InoxSabiana 25/25R range is CE marked according to European Standard EN 1856-1:2009 with the following designations:
InoxSabiana 25/25R with gasket T200 - P1 - W - V2 - L50050 - O * InoxSabiana 25/25R without gasket T450 - N1 - D - V2 - L50050 - O ** InoxSabiana 25/25R without gasket T450 - N1 - D - V2 - L50050 - G **
In addition, the range has been subjected to further tests and has obtained the voluntary mark
(*) øi 100÷300 mm: O50 – øi 350 mm: O75(**) øi 100÷300 mm: O50 / G75 – øi 350 mm: O75 / G115
Sabiana operates under
ISO9001 certified Quality System.
Quality management systemsISO 9001 – Cert. n° 0545/5
Typical composition of a chimney
Certification
SummaryTable
4.4 5.5 6.1 7.3 7.9 9.7 11.4 13.25.1 6.2 7.0 8.3 9.0 11.0 12.9 14.9
0.34 0.36 0.36 0.37 0.37 0.38 0.39 0.39
50
75
75
115
According to EN 13384-1 : 2002
Black coloured silicone rubber450200
N1 (40 Pa) negative pressure operationP1 (200 Pa)
AISI 316L steel, 2B finish, nominal thickness 0.5 mm25 mm thick - Min. density 90 kg/m3 - Tol. 0+30%AISI 304 steel, BA finish, nominal thickness 0.5 mm
Annealed DHP copper 99.9, nominal thickness 0.6 mm
According to EN 13384-1 : 2002Stainless steel
150 180 200 230 250 300 350 400100 130 150 180 200 250 300 350
Outside diametersInside diameters
kg/mkg/m
°C
m2K/W
mm
mm
°C
mmmm
Weight per linear metre, InoxSabiana 25Weight per linear metre, InoxSabiana 25RInner wallRock wool insulationInoxSabiana 25 outer wallInoxSabiana 25R outer wallPressure class with gasketPressure class without gasketMax temperature of the flue gas with gasketMax temperature of the flue gas without gasketGasketThermal resistance of the wall R at 200°C
Average roughness value for the straight lengthFlow resistance coefficient of the insulated componentsMetric screws and bolts
Minimum distance to combustible materials class O(flue serving a boiler on liquid or gas fuel)
Minimum distance to combustible materials class G(flue serving a boiler on solid fuel)
InoxSabiana 25/25R System Chimney with gasket EN 1856-1:2009 T200 - P1 - W - V2 - L50050 - O
InoxSabiana 25/25R System Chimney without gasket EN 1856-1:2009 T450 - N1 - D - V2 - L50050 - O
InoxSabiana 25/25R System Chimney without gasket EN 1856-1:2009 T450 - N1 - D - V2 - L50050 - G
Description of the product:
Standard number:
Maximum operating temperature:
Pressure resistance class (P1 positive press. - N1 negative press.):
Operating conditions (wet flue gas W - dry flue gas D):
Corrosion resistance:
Specification and thickness of the inner wall:
Soot fire resistance class (G: yes – O: no)and distance in mm from combustible materials:
(*) øi 100÷300 mm: O50 – øi 350 mm: O75(**) øi 100÷300 mm: O50 / G75 – øi 350 mm: O75 / G115
**
**
*
Generalcharacteristics:• Element locking bands.
• Resistance to condensate, even under pressure (provided by certified silicone gasket).
• Possibility to turn each element 360° while maintaining the tightness characteristics unaltered.
UniversaldoublewallproductfortheconstructionofchimneysandfluesIts specifications are:
• Rapid installation.
• No thermal bridge between the inner wall and outer wall.
• Compact overall dimensions.
• Perfect mechanical resistance, guaranteed by the locking band.
Designation of the productaccording to EN 1856-1:2009 standard
InoxSabiana25
293
Mainconstructionalcharacteristics:• AISI316Lstainlesssteelinnerwall (austenitic stainless steel 18/10 with low carbon content, grade UNI X 2, CrNiMo 1712).
Thickness: 0,5 mm.
Properties: high resistance to intergranular corrosion and particularly aggressive products.
• AISI304stainlesssteelouterwall (austenitic stainless steel 18/10, grade UNI X 5, CrNi 1810).
Thickness: 0,5 mm.
Properties: good resistance to corrosion in air and water.
Upon request, copper outer wall is available.
• Rockwoolinsulation with basaltic composition, minimum density 90 kg/m3, thickness 50 mm.
Properties: the rock wool used is chemically neutral, is not hydrophilic nor hygroscopic, nor
has a capillary action. It is free of asbestos and crystalline silica, has low conductivity values.
The rock fibres making up the insulation can withstand temperatures exceeding 1000°C.
The insulation is classified as incombustible by the French standard MO-CSTB n°92.34624-3.
• Longitudinalmicroplasmawelding on both the inner and outer wall, in each
element.
• All the non-insulated elements are made from AISI 304 stainless steel (storm collar and
adjustable flashing are made in aluminium). The screws supplied are in stainless steel.
• Minimumthermalbridge between the inner and outer pipe, due to the adoption
of an innovative fastening system.
• Special design of the inner wall so as to allow free expansion according to the flue gas
temperature.
• Insulated individual cardboard packaging for each element.
• Wall brackets and supports with adjustable lengths.
Longitudinal microplasma welding is used
on both the inner and outer wall on each element.
All the non-insulated elements are made from
AISI 304 stainless steel (aluminium adjustable
flashing and storm collar). In addition, the use
of an innovative fastening system means that the
thermal bridge between the inner and outer wall
is reduced to the minimum.
The InoxSabiana 50 series includes 6differentinsidediameters (from350to600mm)and a complete series of accessories for solving
all problems relating to the discharge of the flue
gas from heat generators.
The InoxSabiana50 series is the result
of an innovative constructional design aimed at achieving
a high quality product, versatility and ease of assembly.
The choice of the materials, the use of the latest construction techniques,
the care paid to every accessory, the conformity
with the EuropeanEN1856-1:2009 standard, the continuous checks
on the products and the production process guarantee
the absolute reliability of the Sabiana flues.
The inner wall is made fromAISI316L stainless steel,
0.5 mm thick, while the outer wall is made fromAISI304 stainless steel,
0.5 mm thick, or alternativelycopper, 0.6 mm thick. The insulation
is rock wool, with a minimum density of 90 kg/m3, 50 mm thick.
StainlessSteelDoubleWallFluesInoxSabiana50
InoxSabiana50
295
The InoxSabiana 50/50R range is CE marked according to European Standard EN 1856-1:2009 with the following designations:
InoxSabiana 50/50R T450 - N1 - D - V2 - L50050 - O ** InoxSabiana 50/50R T450 - N1 - D - V2 - L50050 - G **
(**) øi 350÷450 mm: O75 / G115 øi 500÷600 mm: O100 / G150
Sabiana operates under
ISO9001 certified Quality System.
Quality management systemsISO 9001 – Cert. n° 0545/5
Typical composition of a chimney
Certification
SummaryTable
17.5 19.5 22.0 24.0 26.0 28.019.5 22.0 24.5 26.5 29.0 31.5
0.74 0.75 0.76 0.77 0.77 0.78
75
115
100
150
According to EN 13384-1 : 2002
450N1 (40 Pa) negative pressure operation
AISI 316L steel, 2B finish, nominal thickness 0.5 mm50 mm thick - Min. density 90 kg/m3 - Tol. 0+30%AISI 304 steel, BA finish, nominal thickness 0.5 mm
Annealed DHP copper 99.9, nominal thickness 0.6 mm
According to EN 13384-1 : 2002Stainless steel
450 500 550 600 650 700350 400 450 500 550 600
Outside diametersInside diameters
kg/mkg/m
m2K/W
mm
mm
°C
mmmm
Weight per linear metre, InoxSabiana 50Weight per linear metre, InoxSabiana 50RInner wallRock wool insulationInoxSabiana 50 outer wallInoxSabiana 50R outer wallPressure classMax temperature of the flue gasThermal resistance of the wall R at 200°C
Average roughness value for the straight lengthFlow resistance coefficient of the insulated componentsMetric screws and bolts
Minimum distance to combustible materials class O(flue serving a boiler on liquid or gas fuel)
Minimum distance to combustible materials class G(flue serving a boiler on solid fuel)
InoxSabiana 50/50R System Chimney EN 1856-1:2009 T450 - N1 - D - V2 - L50050 - O
InoxSabiana 50/50R System Chimney EN 1856-1:2009 T450 - N1 - D - V2 - L50050 - G
Description of the product:
Standard number:
Maximum operating temperature:
Pressure resistance class (P1 positive press. - N1 negative press.):
Operating conditions (wet flue gas W - dry flue gas D):
Corrosion resistance:
Specification and thickness of the inner wall:
Soot fire resistance class (G: yes – O: no)and distance in mm from combustible materials:
(**) øi 350÷450 mm: O75 / G115 øi 500÷600 mm: O100 / G150
**
**
Generalcharacteristics:• Element locking bands.
• Possibility to turn each element 360°
while maintaining the tightness characteristics unaltered.
UniversaldoublewallproductfortheconstructionofchimneysandfluesIts specifications are:
• Rapid installation.
• No thermal bridge between the inner wall and outer wall.
• Compact overall dimensions.
• Perfect mechanical resistance, guaranteed by the locking band.
Designation of the productaccording to EN 1856-1:2009 standard
InoxSabiana50
297
Mainconstructionalcharacteristics:• AISI316LStainlesssteelwall (austenitic stainless steel 18/10Mo with low carbon content UNI X 2 CrNiMo 1712).
Thickness: 0,5 mm.
Properties: high resistance
to intergranular corrosion and particularly aggressive products.
• Silicone rubbersealinggasket resistant up to 200°C temperature.
• Longitudinalmicroplasmawelding of each element.
• 90°tee made using the deep drawing process.
• allclampingelements in stainless steel AISI 304
(flashing and storm collar in aluminium). The screws supplied are in stainless steel.
All the support and fastening elements are made from AISI 304 stainless steel
(aluminium adjustable flashing and storm collar).
The male and female of each individual element are simultaneously created
by the same belling machine, in order to obtain a perfect coupling calibration
with maximum tolerance equal to +/- 0.15 mm.
The InoxMono series includes 11differentinsidediameters(from80to300mm) and a complete series of accessories for satisfying
all installation requirements.
The InoxMonoSabiana series has been designed
to offer the maximum guarantee of safety and long life in the discharge
of flue gas from heat generators. The choice of the materials, the use
of the latest construction techniques, the care paid to every accessory,
the continuous checks on the products and the production process,
and the quality mark issued by the prestigiousItalianInstituteIMQ,guarantee the absolute reliability of the Sabiana flues.
Each element in contact with the flue gas
is made from AISI316L stainless steel, 0.5 mm thick,
with longitudinal microplasma welding. The 90° T sections,
flue gas monitoring and inspection module are made using
thedeepdrawingprocess,thusavoidingwelding.
StainlessSteelSingleWallFluesInoxMonoSabiana
InoxMonoSabiana
299
The InoxMono Sabiana range is CE marked according to European Standard EN 1856-2:2009 with the following designations:
In addition, the range has been subjected to further tests and has obtained the voluntary mark
Sabiana operates under
ISO9001 certified Quality System.
Quality management systemsISO 9001 – Cert. n° 0545/5
InoxMono Duct with gasket T200 - P1 - W - V2 - L50050 - O
InoxMono Duct without gasket T600 - N1 - D - V2 - L50050 - G
InoxMono Smoke duct with gasket T200 - P1 - W - V2 - L50050 - O50
InoxMono Smoke duct without gasket T600 - N1 - D - V2 - L50050 - G600M
Typical composition of a duct
CertificationSummaryTable
1.1 1.4 1.7 1.8 2.0 2.1 2.3 2.5 2.8 3.5 4.2
Smoke duct: 50
Smoke duct: 600Minimum distance obtained from test
According to EN 13384-1 : 2002
200600
Black coloured silicone rubber
N1 (40 Pa) operation under pressureP1 (200 Pa)
Steel AISI 316L 2B - AISI 316L BA nominal thickness 0.5 mm
According to EN 13384-1 : 2002Stainless steel
80 100 120 130 140 150 160 180 200 250 300Nominal diameterskg/m
mm
mm
°C°C
mmWeight per linear metreMaterial
Pressure class without gasketPressure class with gasket
Max temperature of the flue gas with gasketMax temperature of the flue gas without gasketGasket
Average roughness value for the straight modulesResistance coefficient to components flowMetric screws and bolts
Minimum distance to combustible materials class O(chimney serving a generator with liquid or gas fuel)
Minimum distance to combustible materials class G(chimney serving a generator with solid fuel)
Generalcharacteristics:• Element locking bands.
• Resistance to condensate,
even under pressure (provided by certified silicone gasket).
• Possibility to turn each element 360°
while maintaining the tightness characteristics unaltered.
UniversalsinglewallproductfortherealisationofreliningandsmokeductsIts specifications are:
• Rapid installation.
• Compact overall dimensions.
• Perfect mechanical resistance, guaranteed by the locking band.
InoxMono Duct with gasket EN 1856-2:2009 T200 - P1 - W - V2 - L50050 - O
InoxMono Duct without gasket EN 1856-2:2009 T600 - N1 - D - V2 - L50050 - G
InoxMono Smoke Duct with gasket EN 1856-2:2009 T200 - P1 - W - V2 - L50050 - O50
InoxMono Smoke Duct without gasket EN 1856-2:2009 T600 - N1 - D - V2 - L50050 - G600M
Description of the product:
Standard number:
Maximum operating temperature:
Pressure resistance class (P1 positive press. - N1 negative press.):
Operating conditions (wet flue gas W - dry flue gas D):
Corrosion resistance:
Specification and thickness of the inner wall:
Soot fire resistance class (G: yes – O: no):
Distance in mm from combustible materials:
Designation of the productaccording to EN 1856-2:2009 standard
InoxMonoSabiana
301
Technicalcharacteristicsofthemaincomponents:Cabinet: made from hot galvanised metal plate, epoxy powder painted, furnace baked.
Class of protection of the unit IP 20.
Fanassembly: made up of aluminium tangential fans
with concave fins positioned in a spiroidal configuration along the length of the fan.
Motor: single phase 230V 50Hz, two speeds.
Hotwatercoil(MU-W,MC-W): theWseries
are complete with a hot water coil (for heating only), made from copper pipes
with aluminium fins bonded to the pipes by mechanical expansion.
Maximum water temperature 100°C, maximum operating pressure 8 bars.
The coils are fitted with female threaded fittings 3/4” forMCmodels
and male threaded fittings 1/2” forMU models.
The coils have either 2 rows, forMCmodels, or 1 row forMU models.
Electricheater(MU-E,MC-E): theEseries
come with sealed electric resistances or galvanised steel filament resistances.
MeltemiDoorCurtain
The range ofMeltemiSabiana door curtains
offers the maximum flexibility in the protection of doors
and open access compartments. The door curtains are available
in the air ventilation version, with hot water coil and with electric resistance,
the3differentversions are supplied in12differentmodelswith lengths from 1064 mm to1570 mm that are suitable
for door heights from 2,5 m to 4 m in commercial installations.
Thanks to their modularity, the door curtain units
canbeconnectedtogether to give a continual air barrier
of the desidered length to protect large doors.
Meltemi
303
The MU range of modular door curtains forofficesandcommercialenvironmentscombines the benefits of the most advanced aeraulic
technology with the flexibility of a modular system.
These very compact units can be fitted individually or joined to create
a continuous door curtain. The remote controls and the connection kit allow any number of
units to be managed by one single control. The high performance tangential fans coupled
with a powerful “twin shaft” motor provide each module the best performance characteristics
for entrances up to 2.5m in height, offering protection against winter cold, summer heat, dust
and pollution.
The MC range of modular door curtains forlarger commercial applications uses
powerful “twin shaft” motors and high efficiency
tangential fans to provide thermal protection for entrances up to 4m
in height. The 1m and 1.5m modules can be joined to create a continuous door curtain and
an uninterrupted unit profile. Every unit contains a power board so that a single control can
be connected to several modules.
Air throw
HIGHSPEED
HIGHSPEED
MC-1000/1500E
MU-1000/1500E
MC-1000/1500A
MU-1000/1500A
MC-1000/1500W
MU-1000/1500W
1064
1564
1070
1570
11
16
26
34
300
300
417
417
17
23,5
29
38
200
200
280
280
18
26
30
39
DIMENSIONS (mm) WEIGHT (kg)
A A SERIESB W SERIESC E SERIES
MU-1000MU-1500MC-1000MC-1500
MODEL
HorizontalinstallationONLY
HorizontalinstallationONLY
HorizontalandVerticalinstallation
HorizontalandVerticalinstallation
400V~ (3p+N)
230V~
230V~
HorizontalinstallationONLY
1250/900
4,5
9,0
53/45
21/30
0,5
1150/850
7,1/6,4
52/47
18/20
0,5
1250/900
53/45
0,5
1900/1160
6,8
13,5
53/40
21/34
0,6
1700/1100
11,3/8,7
48/40
19/23
0,6
1900/1160
53/40
0,6
2400/1700
6
12
64/54
15/21
2,4
2200/1520
15,5/12,5
62/54
20/24
2,3
2400/1700
64/54
2,3
3600/2300
9
18
64/55
15/22
2,9
3300/1870
23,4/17,3
64/58
22/27
2,9
3600/2300
64/55
2,9
MU-1000E
MU-1000W
MU-1000A
MU-1500E
MU-1500W
MU-1500A
MC-1000E
MC-1000W
MC-1000A
MC-1500E
MC-1500W
MC-1500A
MODEL
MODEL
MODEL
m3/h
kW
kW
dB(A)
°C
A
V
m3/h
kW
dB(A)
°C
A
V
m3/h
dB(A)
A
V
Air flow
Emission 1st stage
Emission 2nd stage
Sound pressure 1
∆t 3
Absorption
Voltage
Air flow
Emission
Sound pressure 1
∆t 2
Absorption
Voltage
Air flow
Sound pressure 1
Absorption
Voltage
1 = The sound pressure levels are measured at a distance of 5m; directional effect with factor 2 (hemispherical emission with unit hung in the centre of the ceiling); equivalent area of absorption = 200m2 (Sabine).2 = Water temperature 80/60°C, Entering air temperature + 15°C.3 = Increase in air temperature with the resistance in 2nd stage operation and low/high air flow.
Aseries-airventilationonly
Wseries-withhotwatercoil
Eseries-withelectricresistance
Dimensions, Weight and Technical data
Meltemi
305
Technicalcharacteristicsofthemaincomponents:• Covering unit
made out of stove-enamelled phosphated steel plate panels.
• Supporting frame in galvanised steel plate.
• Coil with protected electrical resistances, in finned steel pipe.
The power is divided into two stages in order to allow it to operate at partialized load.
• Helicoidal fan with light alloy, anti-spark blades,
directly connected to the motor axis.
• Asynchronous400V-3f-50Hz,6-polemotor,
with closed construction, class B insulation and IP 44 protection.
• Electrical fan support with sturdy metal basket made of four radial arms
and safety mesh basket in round steel pipe.
The junction between the support and the rear wall of the casing is created by
interposing neoprene anti-vibration supports that ensure operation without
vibrations and resonance.
• Safety thermostat against overheating.
• Terminal board for electrical connections.
ElectraMaticModel:
• Electric motor equipped with thermal protection,
incorporated in the wiring, with automatic re-insertion.
• Electrical control panel completely accessible by removing a side panel.
Itincludesall control and protection automations,
the auxiliary circuits with safety thermostats and the terminal boards
ready to be connected to the supply, to the remote control panel, to room thermostat, etc.
TheElectra90 electric unit heaters for horizontal discharge are made
in7sizes, with heat outputsform6to36kW. The electrical coil has
two-stage sealed electrical resistance made of finned steel tubes, to allow
two step operation. The power supply is three phase, 400 V - 50 Hz.
TheElectraMatic electric unit heaters for horizontal discharge are made
in5sizes, with heat outputsfrom6to24kW. The electrical coil has
two-stage sealed electrical resistance made of finned steel tubes, to allow
two step operation. The power supply is three phase, 400 V - 50 Hz. These
unitscomewith an electrical control panel that includes the auxiliary
circuits, operating and safety thermostat, and terminal block ready for
connection to the line, to the remote control panel and to the room thermostat.
ElectricUnitHeaterElectra90/ElectraMatic
Electra90/ElectraMatic
307
Bracketsfor wall installation
Accessories
Control
Remote switch
(for ElectraMatic only)
Electra90/ElectraMatic
Dimensions,Weight and Technical data
6480
3240
3240
1000
33
6
2.5
4.0
0.22
900
110
43
570
470
400
320
300
32
30
9720
3240
6480
1000
44
6
2.5
4.0
0.22
900
110
43
570
470
400
320
300
35
33
11100
5550
5550
1800
35
8
3.0
4.5
0.22
900
110
48
650
570
480
420
400
43
41
16650
5550
11100
1800
44
8
3.0
4.5
0.22
900
110
48
650
570
480
420
400
45
43
24000
6000
18000
3600
36
12
3.0
5.0
0.47
900
230
50
730
670
560
520
500
60
58
30000
12000
18000
3500
42
12
3.0
5.0
0.47
900
230
50
730
670
560
520
500
–
61
36000
12000
24000
3400
47
12
3.0
5.0
0.47
900
230
50
730
670
560
520
500
–
64
EM6 EM9 EM11 EM17 EM24 – –
06E 09E 11E 17E 24E 30E 36E
MODEL ElectraMatic
MODEL Electra 90
W
W
W
m3/h
°C
m
m
m
A
r.p.m.
W
dB(A)
mm
mm
mm
mm
Ø
kg
kg
1st
2nd
A
B
L
h
Min.
Max.
Power steps
Dimensions
Air outlet section
Mounting height
Helicoidal fan
400 V - 3f - 50 Hz
Air flow
Leaving air temp. (entering +15°C)
Throw
Noise level at 5 m
Fan
Weight (approx.) ElectraMatic
Weight (approx.) Electra 90
Output
309
Technicalcharacteristicsofthemaincomponents:Version: three-phase 400 V~ (3p + N) or single-phase 230 V~.
Only for vertical installation.
Casing: in hot dip galvanised and pre-painted steel;
it is easily removed for complete access to the unit.
The air outlet grill, located on the upper part of the unit,isreversible.
Fanassembly: made of ultra-silent double intakecentrifugalfanswith statically and dynamically balanced aluminium impellers
keyed directly onto the motor shaft.
Electricmotor: the motor has three speeds with capacitor,
and is fitted on sealed for life bearings and is secured on anti-vibration
and self-lubricating mountings. Protection IP 20, class B.
Coil: protected electrical resistances with firmed steel pipe.
The power is divided into two stages
in order to allow it to operateatpartializedload.
Electricalpanel: includes all control and protection automations,
auxiliary and safety circuits and the terminal board, ready for connections to the supply line.
Control: built-in control
with ON-OFF switch, speed switch and room thermostat.
TheFSE electric fan convectors are made in 5 sizes,
with heat outputsfrom3to8,5kW.
The electric coil has two-stage sealed electrical
resistance made of finned steel tubes to allow two step operation.
The power supply is three phase, 400 V - 50 Hz.
The first two sizes(upto4,5kW) can also be supplied
in the single-phase version.
Asstandard they are fitted with two speed control,
room thermostat and switch for electric heater two step operation.
FSEElectricFanConvector
FSE
311
Mounted fitted control
- ON-OFF switch.
- Manual 3 speed switch: • Fan only at low speed. • Low heating power at medium speed. • High heating power at high speed.
- Simultaneous thermostatic control of the electric heater and fan.
The unit is equippedwith a manually reset safetythermostat that stops power
to the electrical coil.
FSE
3
1000
8,50
125
59
50
2
800
5,60
85
56
47
1
650
-
65
48
39
3
300
3,00
50
50
41
2
240
1,90
30
45
36
1
190
-
20
40
31
3
450
4,50
60
52
43
2
360
2,90
50
47
38
1
290
-
45
42
33
3
300
3,00
50
50
41
2
240
1,90
30
45
36
1
190
-
20
40
31
3
450
4,50
60
52
43
2
360
2,90
50
47
38
1
290
-
45
42
33
3
600
6,00
95
51
42
2
480
4,00
80
42
33
1
380
-
60
35
26
3
1000
7,50
125
59
50
2
800
5,00
85
56
47
1
650
-
65
48
39
13,5 20,0 5,0 7,0 9,5 10,0 13,0
230V~ 400V~(3p+N)
FSE 5FSE 4FSE 3FSE 2FSE 1FSE 2FSE 1MODEL
m3/h
kW
W
ampère
dB(A)
dB(A)
Speed
Air flow
Heat output
Motor output
Absorbed power (*)
Sound power Lw
Sound pressure (**) Lp
(*) = Figures at high power and high speed.(**) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec.
454
669
884
1099
1099
775
990
1205
1420
1420
27
31
39
45
45
DIMENSIONS (mm) WEIGHT WITH PACKAGING
B L kg
FSE 1FSE 2FSE 3FSE 4FSE 5
MODEL
Dimensions,Weight and Technical data
Damperfor fresh air intake
(not motorizable)SAE
Aluminium intake grid
To be installed with PAP feet.GAP
FeetPAP
Accessories
313
Technicalcharacteristicsofthemaincomponents:• Case in stove-enamelled steel, in light grayRAL7038.• Switch controlled two speed silent electrical fan unit.
• Coil with single phase 230V electrical resistances in aluminium and finned to allow
uniform heat exchange. The coil power is divided into two stages
in order to allow it to operate at partialized load.
Available upon request withlowtemperaturecut-outthermostat.
Dimensions,Weight and Technical data
ThePrimula fan convectors
are units designed for heating residential and commercial environments
in the place of traditional static radiators.
They are available in3sizes with electric heaters.
MiniconvectorPrimula
Prim
ula
PE 20PE 15PE 10MODEL2000
1000/2000
260
150
44
35
960
16
1500
1000/1500
170
100
43
34
760
14
1000
700/1000
120
70
43
34
560
10
W
W
m3/h
m3/h
dB(A)
dB(A)
mm
kg
Dimensions
Weight
High speed
Low speed
High speed
Low speed
(A)
Noise level at 2 m
Air flow
Power steps
Electric heater output
for 80 Yearsa Leading Positionin the Air Conditioning
The descriptions and illustrations provided in this publication
are not binding: Sabiana reserves the right,
whilst maintaining the essential characteristics
of the types described and illustrated, to make, at any time,
without the requirement to promptly update
this piece of literature, any changes that it considers useful
for the purpose of improvement or for any other manufacturing
or commercial requirements.
www.sabiana.it
Product Range
2013
Sabiana s.p.a. • via Piave, 53 • 20011 Corbetta • Milano • Italyphone +39.02.97203.1 r.a. / +39.02.97270429 / +39.02.97270576 • fax +39.02.9777282 / +39.02.9772820
www.sabiana.it • [email protected]
PROD
UCT
RANG
ENO
VEM
BER
2013
PR -
EX
- 11
/13
Cod.
A401
0100
A/1
1/13