Roxar Multiphase Salinity System
Data Sheet
Direct, continuous measurement of water conductivity in a multiphase flow
Measuring conductivity / salinity of the produced waterfrom a well has become increasingly important as a keyoperational parameter for many operators.
Key features• Compact design, consists of a pipe spool and an
Exd flow computer mounted typically upstream of the multiphase meter
• Stand-alone product based on modularity, allowing integration with both new and existing multiphase meters
• Real-time continuous outputs of both water conductivity and salinity
• Low uncertainty and large operating range
Roxar Multiphase Salinity System - A new innovation from Roxar, thepioneer in multiphase flow metering
Added Value for Customer• Salinity independent multiphase measurement • Formation water detection and break-through
monitoring• Flow assurance, e.g. optimise corrosion,
erosion and scale inhibitors• Reservoir management purposes e.g. maximise oil
production /minimise water coning• Injected water monitoring
With the introduction of this product to the Roxar portfolio, for those applications which demand high accuracy, or are experiencing high watercuts and unstable salinity, Roxar are able to offer the RMSS as a solution to support and enhance the multiphase measurement achieved by the Roxar Multiphase meter.
RMSS
www. roxar. com
FM-T404-A/260814Specif icat ions
System performance and characteristicsOperating range:• Wtr (1) - 100% Water in Liquid Ratio (WLR)• 0 - 80%(2,3) Gas Volume Fraction (GVF)
Meter sizes:• 2” to 6”, other sizes available upon request
Installation:• Vertical upwards flow, preferably downstream
of a blind-T (Typically upstream of the Roxar Multiphase meter)
Typical uncertainty (90% confidence int.):• +/-0.5 abs Siemens/meter conductivity• +/-0.5 abs % Salinity (NaCl)
Design pressure:• 5000 psi (345 bars)
Design temperature:• -20 to +130 °C (-4 to +266 °F)(1) Water transition point(2) Operating range can be extended towards 90% GVF dependent
on operating pressure and flow profile(3) 90 – 100% covered by the Roxar Wetgas Salinity System
Mechanical and electrical componentsWetted parts materials:• Duplex UNS 31803• Inconel N06625
Other materials available upon request
Ex d electronic canister material:• Stainless steel
Flange connection:• Grayloc®/Techlok® hub, ANSI or Weldneck
Length:• 750 mm (same for all meter sizes)
Sensor technology• Microwave transmission sensor• 3-pin probe configuration
Power supplyVoltage:• 24 VDCPower consumption:• 24W
Communication interfacePorts:• RS-485 x 2Communication protocol:• Modbus
Electrical certification• ATEX and IECEx (Ex d e [ib] IIB T5 Gb)• EMC (Nemko E14033.02)
Ex d Ingress protection• IP 66
Sun
dh
eim
-Mad
iso
n 0
8-20
14
Roxar Multiphase Salinity System (RMSS)
For further information please contact your regional office or email: [email protected] or visit www.roxar.com
Asia Pacific Tel: +60 3 2177 4450Australia Tel: +61 8 9208 1680Latin America Tel: +55 212 222 1941West Africa Tel: +27 71 60 61 737
Head Office Tel: +47 51 81 88 00CIS Tel: +7 495 504 3405Europe Tel: +47 51 81 88 00North America Tel: +1 281 879 2600Middle East Tel: +971 4 811 8100