Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate
Matter Concentrations
Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun Tao
Purdue University, West Lafayette, IN
Larry JacobsonUniversity of Minnesota, St. Paul, MN
Jacek KozielTexas A&M University, Amarillo, TX
Steven HoffIowa State University, Ames, IA
Yuanhui ZhangUniversity of Illinois, Urbana, IL
Jerry BaughmanNorth Carolina State University, Raleigh, NC
![Page 2: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/2.jpg)
ObjectivesDescribe use of TEOM in livestock
buildings to measure TSP, PM10 and PM2.5.
Discuss QAQCShow some preliminary data
collected this year
![Page 3: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/3.jpg)
Laying House PM
![Page 4: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/4.jpg)
![Page 5: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/5.jpg)
![Page 6: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/6.jpg)
Dust Measuring Strategies Determine temporal variation (Hinze et al., 1998)
Semi-continuous mass monitor Representative exhaust fan (minimum winter)Calibrate with FRM
Determine spatial variation (Wang et al., 1999)Multi-point gravimetric filter samplingMultiple exhausts plus ambientCalibrate with FRM
![Page 7: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/7.jpg)
TEOM flow schematic Sampling Inlet
Vacuum Pump
Sensor Unit
Flow Splitter
Control Unit
3.00 l/min
Main Flow 13.67 l/min
Aux. Flow Flow Controller
Filter
![Page 8: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/8.jpg)
TEOM record in a pig house (Hinz et al., 1998)
![Page 9: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/9.jpg)
PM Monitoring Schematic
Barn I n strument
shelter
TEOM control ler uni t
DAQ
TEOM sensor and inlet
PREF Ventilation fan
Cables and heated vacuum
lines
![Page 10: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/10.jpg)
Raceway Contains Vacuum Lines
![Page 11: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/11.jpg)
TEOM PM10
![Page 12: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/12.jpg)
![Page 13: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/13.jpg)
System Calibration
Flow controller calibration (software) Mass flow controller calibration (hardware) Analog calibration Mass transducer verification Flow audit procedure Ambient temperature calibration Barometric pressure calibration
![Page 14: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/14.jpg)
TEOM Maintenance Filter replacement PM-10 inlet cleaning Replacing large bypass in-line filter Replacing flow controller filters Cleaning air inlet system Leak testing
![Page 15: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/15.jpg)
Changing TEOM Filter
![Page 16: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/16.jpg)
Loaded TEOM Filter
![Page 17: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/17.jpg)
“Feathered” Bug Screen
![Page 18: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/18.jpg)
Plugged Bug Screen
![Page 19: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/19.jpg)
PM10 Inlet Body
![Page 20: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/20.jpg)
Large Particles Collected
![Page 21: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/21.jpg)
Collocated TEOMS, FRM
Faninlet
External screen
PM10
inlet
Cabinet
Wedding PM10
![Page 22: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/22.jpg)
Collocated PM10 Measurements24-h at laying house exhaust
0
200
400
600
800
1000
1200
1400
1600
0 2 4 6 8 10 12 14 16 18 20 22 0
Time of day, h
Con
cent
ratio
n,
g/m
3 TEOM ATEOM B
`
Lights on
Lights off
Anticipatory Feeding
![Page 23: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/23.jpg)
Four Collocated TEOMs in laying house exhaust (4/3/02)
0
400
800
1200
1600
0 2 4 6 8 10 12 14 16 18 20 22 0
Time of day, h
Con
cent
ratio
n,
g/m
3 TEOM ATEOM BTEOM CTEOM D
![Page 24: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/24.jpg)
TSP vs. PM10 in Laying House Exhaust Air (5/2/02)
0
400
800
1200
1600
2000
2400
0 2 4 6 8 10 12 14 16 18 20 22 0Time of day, h
Con
cent
ratio
n,
g/
m3 TSP A
PM10 B
TSP C
![Page 25: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/25.jpg)
Collocated PM2.5, PM10, TSP at laying house
0
400
800
1200
1600
2000
2400
2800
0 2 4 6 8 10 12 14 16 18 20 22 0
Time of day, h
Con
cent
ratio
n,
g/m
3
TSP
PM10
PM2.5
![Page 26: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/26.jpg)
Effect of Filter Loading
0
400
800
1200
1600
2000
2400
0 2 4 6 8 10 12 14 16 18 20 22 0Time of day, h
Con
cent
ratio
n,
g/m
3 New filterLoaded filter
Humidity Effect
![Page 27: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/27.jpg)
Lagoon
Tunnel-ventilated finishing houses
with flushing
Oil sprinkledbuilding
![Page 28: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/28.jpg)
Oil Sprinkling
![Page 29: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/29.jpg)
![Page 30: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/30.jpg)
Oil pressure
![Page 31: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/31.jpg)
![Page 32: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/32.jpg)
TSP Measurements in Two Swine Barns (11/08/02)
0
500
1000
1500
2000
2500
3000
3500
4000
0 2 4 6 8 10 12 14 16 18 20 22 0
Time of day, h
Con
cent
ratio
n,
g/m
3
Amb
Barn B
Barn A
![Page 33: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/33.jpg)
Effect of Pig Activity on TSP
-4000
-3000
-2000
-1000
0
1000
2000
3000
4000
0 2 4 6 8 10 12 14 16 18 20 22 0
Time of day, h
Con
cent
ratio
n,
g/
m3
0
0.2
0.4
0.6
0.8
Activ
ity, V
TSP
Activity
![Page 34: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/34.jpg)
Nine shrouded vanes installed at laying house
Open vane (cheaper)
50% variations with static pressure!
![Page 35: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/35.jpg)
UIUC test of anemometer
Calibration atUIUC BESS Lab
![Page 36: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/36.jpg)
Open impeller vane anemometer
![Page 37: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/37.jpg)
Open propeller
![Page 38: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/38.jpg)
Small Vane Anemometer Readings vs. Building Static Pressure
0
0.1
0.2
0.3
0.4
0 2 4 6 8 10 12 14 16 18 20 22 0
Time of day, h
Ven
tilat
ion
rate
, m3/s
-75
-50
-25
0
25
50
75
100
125
150
dP, p
a
Fan 3
dP
![Page 39: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/39.jpg)
Summary First measurements of TSP, PM10 and
PM2.5 in livestock buildings in U.S. have been conducted.
QAQC is critical to TEOM success. Moisture is adsorbed and desorbed Oil sprinkling reduces PM Real-time concentrations correlated to
animal activity Anemometers provide real-time airflow
data.
![Page 40: Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun](https://reader036.vdocuments.site/reader036/viewer/2022062417/55181e4c550346a7318b4901/html5/thumbnails/40.jpg)
Check out www.AgAirQuality.com
Questions?