Advances in Compact Flotation Unitsfor the Treatment of Produced Water
Produced Water & EnvironmentalConference - Aberdeen
June 5-6, 2013
Mike BhatnagarSr. Product Manager
![Page 2: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/2.jpg)
TST-CFUTM
Process & Compression SystemsCustom Process Systems2
Cameron is a leading provider of branded flow equipment products,systems and services to worldwide oil, gas and process industries.
![Page 3: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/3.jpg)
OIL GAS WATER SOLIDS
• Free Water Knockout
• TS WKO™ CompactFree Water Knockout
• NATCO® MechanicalHeater Treaters
• Multi PhaseSeparators
• PORT-TESTRevolution®
• CONSEPT ICD®
• NATCO® DualFrequency®
• NATCO® DualPolarity®
• PETRECO® Bilectric®
• PETRECO® MeterCell
• CES™ CompactCoalescer
• Bilectric HF™
• Cynara® CO2
• PureMEG™ MEGReclamation
• Shell / Paques• THIOPAQ®
• PORT-TESTWhirlyScrub I™, V™
• PORT-TESTRevolution®
• CONSEPT DC™• CONSEPT IVD™• CONSEPT SI™• CONSEPT Spinlet™• CONSEPT ACI™• NATCO® CHF® Heater• NATCO® BTEX Buster®
• NATCO® Desi-Dri®
• NATCO® SHV™Flare/Combuster
• NATCO® Water BathHeaters
• NATCO® Glymine• Amine Treating• Glycol Dehydration• Mechanical
Refrigeration• NATCO® Jewel T®
Produced Water Seawater • MOZLEY™ WellheadDesander
• MOZLEY™Desanding SLC
• MOZLEY™Microspin
• MOZLEY™Hydrotrans™
• MOZLEY™Fluidizer™
• MOZLEY™Deltaclone™
• MOZLEY™Sandcleaning
• UNICEL®Vertical SkimVessel
• WEMCO® Pacesetter®
• NATCO® Cross-FlowScrubber
• VORTOIL® DeoilingCyclones
• WEMCO® ISF®
• WEMCO®Depurator®
• UNICEL® IGF• NATCO® Versaflo™• PETRECO®
Hydromation® Nutshell• PETRECO® Silverband
Nutshell• PETRECO® Softeners• NATCO® Skim Pile• NATCO® DOX®• TS CFU™ Compact
Flotation
• METROL® SeaCell®
• METROL® BFCC™
• METROL SeaScreen& SeaScreen Max
• Media Filters
• Vacuum Deaerators
• Gas Strip Deaerators
• Polymem UF
• NATCO® SulphateRemoval
• CDX™ CompactDeaeration
Custom Process Systems - Portfolio
![Page 4: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/4.jpg)
TS Technology acquired by Cameron Custom Process Systems
Custom Process Systems
2004 2011
1990 20101997 20011999 2002 2007
Baker HughesProcessSystems(BHPS)
formed fromBaker HughesIndustries &WEMCO with
Metrol
Custom ProcessSystems
PetrecoInternationalacquired byCameron
BHPSacquiresBFCC
BHPSacquiresVortoil
1990 20101993 1995 1997
BHPSacquiresPetreco
19981996 2001
Sequal Holdingspurchases BakerHughes Process
Systems fromBaker Hughes
creating PetrecoInternational
2002
PetrecoInternational
acquiresKCC
Process
PetrecoInternational
acquires
Unicel
TEST
CYNARAMembranes
MPE
ESI
Axsia
PORTA-TEST
ConSepT
Mozley
BakerHughes
Industries
WEMCOOil &
Gas withMetrol
BHPSacquiresKrebs
20001998
NATCOAcquired by
Cameron
Cameronacquires
TSTechnology
![Page 5: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/5.jpg)
Divider graphic should fill and notexceed the defined gray box.
Custom Process Systems5
Produced Water Treatment TrendsNext Generation Compact Flotation - TST CFU
Field Trials – North SeaField Test Results
Summary of other Field Test Results and Full Scale InstallationsConclusions and Future Work
![Page 6: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/6.jpg)
Produced Water Trends – Onshore Applications
• Globally produced water associated with the oil & gas productionis between three and seven times than the oil production and itcontinues to increase over the lifespan of the well.
• Onshore produced water is usually treated and re-injected intounderground formations, or treated and discharged underpermits issued by regional agencies.
• Cameron’s WEMCO Depurator Flotation Systems and thePetreco Hydromation Nut Shell Filters are well established inthese applications.
Custom Process Systems6
![Page 7: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/7.jpg)
Produced WaterTreatment
Compression Compression Gas Export
Knockout
DrumGas
Treatment /Dehydration
CrudeExport
ProducedWater for re-
injection
HYDROMATIONNutshell Filter
WEMCOFlotation
WEMCOCPI
SkimmingsSeparation
HPProductionSeparator
LP ProductionSeparator
ElectrostaticDehydrator
WellheadChoke
Typical OnshoreSeparation PFD
Bulk PhaseSeparation
ElectrostaticCrudeConditioning
Gas Treatmentand Conditioning
Solids SeparationSystem
WellheadDesanders
Pressurereducing
Pressurereducing
SandClean System
SandDisposal
Water
FromWellhead
Cartridge FilterAdsorption
![Page 8: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/8.jpg)
8
WEMCO ® Depurator ®
ConventionalBox Design
CylindricalDesign
![Page 9: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/9.jpg)
Custom Process Systems9
Petreco® Hydromation® Nut Shell Filters
![Page 10: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/10.jpg)
Produced Water Trends – Offshore Applications
• Most offshore produced water is treated and discharged to theocean as permitted by the regional agencies.
• In the past, many offshore operators have adopted a trendtoward the use of de-oiling hydrocyclones followed byconventional flotation, degasser or conventional compactflotation to treat produced water prior to overboard discharge.
Custom Process Systems10
![Page 11: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/11.jpg)
Compression Compression Gas Export
Knockout
DrumGas
Treatment /Dehydration
CrudeExport
ProducedWater forDisposal
SkimmingsSeparation
HP ProductionSeparator
LP ProductionSeparator
ElectrostaticDehydrator
Cartridge FilterAdsorption
WaterRecycle
OilRecycle
DesandingHydrocyclone
Deoiler
Deoiler
ProducedWater for re-
injection
ConventionalFlotation /
Degasser/ CFU
Typical OffshoreSeparation PFD
Produced WaterTreatment
ElectrostaticCrudeConditioning
Gas Treatmentand Conditioning
Bulk PhaseSeparation
DeltaClone
Solids SeparationSystem
WellheadDesanders
PressureReducing
Pressurereducing
SandClean System
SandDisposal
WellheadChoke
![Page 12: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/12.jpg)
12
Vortoil ® Deoiling Hydrocyclone
Inserted Sandwiched OriginalOffset
ModifiedManufacturedOffset
Super Offset
Value Engineeredover 20+ years
![Page 13: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/13.jpg)
13
Unicel ® Vertical Flotation
![Page 14: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/14.jpg)
Offshore Production Trends, continued…
• Oilfield operating companies continue moving to ever-increasing waterdepths to produce oil and gas reserves. The high cost of constructingfloating platforms, is driving the need to reduce the size and weight oftopsides processing equipment on these platforms.
• The challenges for the operators are increasing and the need for highperformance, compact and more cost effective technologies exists thatcan handle the high water cuts.
• This has lead to the development of the next generation TST-CFUTM, thathas multiple stages in a single vessel making it capable of handlinghigher inlet OIW concentrations.
• The TST-CFUTM offers better performance than that achieved by acombination of multiple technologies like Hydrocyclones, ConventionalFlotation or Compact Flotation units, considerably reducing the need forfoot print and weight.
Custom Process Systems14
![Page 15: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/15.jpg)
Divider graphic should fill and notexceed the defined gray box.
Custom Process Systems15
Produced Water Treatment TrendsNext Generation Compact Flotation - TST CFU
Field Trials – North SeaField Test Results
Summary of other Field Test Results and Full Scale InstallationsConclusions and Future Work
![Page 16: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/16.jpg)
Next Generation Compact Flotation – TST CFUTM
• The TST-CFUTM uses gas flotation andadditional hydraulic forces to separateand remove hydrocarbons, aromaticcompounds, hydrophobic substancesand fine solid particles from producedwater.
• The TST-CFU is available as a singlestage vessel or as a single vessel withmultiple internal stages offering acompact solution specially designed tohandle higher inlet oil concentrations,over 1,000mg/l.
• It requires a smaller foot print, has areduced weight than competitivetechnologies.
• The technology is world wide patentpending.
Custom Process Systems16
![Page 17: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/17.jpg)
TST CFU – Compact Flotation Technology
• The Technology uses bothinduced, and dissolved gasflotation to removehydrocarbons.
• Special internals for mixingof gas and oil have beendeveloped to achieve easyseparation of this mixturefrom the water.
• The water can be treatedthrough several stages withinone vessel. It s available inconfigurations up to 4stages.
• The numbers of stagesdepend on the inlet fluidconditions.
17 Custom Process Systems
Direction of flow
Orifice /Valve/Mixer
Gas
Water
Orifice /Valve
Gassaturated water at pressure P1
Pressure P2Pressure P1P1 > P2
Direction of flow
Induced gas flotation
Dissolved gas flotation
![Page 18: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/18.jpg)
TST CFU Basic (Single stage vessel)
• The TST-CFUTM design consists of specialinternals that include a static mixture, ariser pipe, distribution arms and guidevanes.
• Improved produced water circulation andre-mixing is crucial to the design of TST-CFUTM system to enhance the oilseparation efficiency and reduce theretention time down to 20 seconds perstage.
• Key parameters like downward fluidvelocity, gas bubble size, fluid circulation,internal flow paths, gas bubble re-mixing aswell as cell residence time, gas inductionrates, skimming rates, and their effects onprocess hydrodynamics have been takeninto consideration when designing this nextgeneration compact flotation technology.
Custom Process Systems18
1st stagewithoverlappingguide vanes
Cleanwaterwithoutbubblesbelow thevanes
Inletnozzle
![Page 19: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/19.jpg)
CUSTOM PROCESS SYSTEMS19
TST CFU – Gas bubble distributuion and re-mixing
![Page 20: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/20.jpg)
TST CFUTM MS3 (Three stage vessel)
Custom Process Systems20
• CFD analysis was used to improve theefficiency of the internal guide vanes byretaining more of the swirling oil watermixture and providing an upward flowpattern to the rising gas bubblesattached to the oil.
• The proper distribution of gas bubblesover the entire cross-sectional area ofthe vessel, the re-mixing of the gasbubbles, the size of the bubbles inducedinto the produced water are all critical topromote good oil separation
• Much shorter retention times of around20 seconD/S per stage has resulted in amore compact vertical pressure vesseland smaller reject volumes.
• The result is an enhanced CFU designwith multiple stages in a single vessel ascompared to the single stage design ofthe conventional vertical IGFs andconventional Compact Flotation Units.
Stage 1
Stage 2
Stage 3
PW inlet
Treated waterOutlet
![Page 21: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/21.jpg)
TST CFUTM MS3 (Gas inlet and oil reject lines)
Custom Process Systems21
Gas recycleStage 1
Reject stage 1
Reject stage 2
Reject stage 3
Gas InletStage 2
Produced Water Inlet
Treated Water outlet
![Page 22: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/22.jpg)
Divider graphic should fill and notexceed the defined gray box.
Custom Process Systems22
Produced Water Treatment TrendsNext Generation Compact Flotation - TST CFU
Field Trials – North SeaField Test Results
Summary of other Field Test Results and Full Scale InstallationsConclusions and Future Work
![Page 23: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/23.jpg)
Field Trials – North Sea
Custom Process Systems23
Existing System:• 1st stage separator• 2nd stage separator• Flocculation tank• 1st stage hydrocyclones• 2nd stage hydrocyclones• Degassing tank• Single stage existing
compact flotation unit
Tie-in points :• Downstream of the
degasser• Downstream of the 1st
stage hydrocyclones• Downstream of the 2nd
stage hydrocyclones• Downstream of the 1st
stage separator
![Page 24: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/24.jpg)
TST-CFUTM Test Skid
• The TST-CFU test-skidconsisted of two compactflotation units, the CFU Aand CFU B with differentinternal designs.
• The test allowed CFU Aand CFU B to be operatedindividually, in series or inparallel.
Custom Process Systems24
![Page 25: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/25.jpg)
Inlet Oil/ water Specifications
Custom Process Systems25
Oil API 30.0Oil Density (150 C) [kg/l] 0.8759
PW Temperature[°C] 70PW pH 7.1-7.2
OIW levels in PW from existing treatment system
![Page 26: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/26.jpg)
Test Procedures
• Tests at different tie-in points
• Flow rate (Typical 50; 100; 150% of design)
• Gas rate injection variation
• Tests performed with and without flocculants
• Testing with the normal variation of incoming water
• Measure OIW & Oil droplet size
Custom Process Systems
Testing instruments
• OIW field instrument calibrated with the existing plant’spermit monitoring instrument
• Malvern Mastersizer Oil droplet size and particle sizemonitoring
• Malvern Zeta-sizer used when oil droplet surface chargewas problematic (especially for condensate water)
![Page 27: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/27.jpg)
Divider graphic should fill and notexceed the defined gray box.
Custom Process Systems27
Produced Water Treatment TrendsNext Generation Compact Flotation - TST CFU
Field Trials – North SeaField Test Results
Summary of other Field Test Results and Full Scale InstallationsConclusions and Future Work
![Page 28: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/28.jpg)
North Sea Test Results - Tie in Points
Custom Process Systems28
![Page 29: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/29.jpg)
Single Stage TST-CFU - D/S of the degasser
• The incoming OIW wasaround 20 mg/l with afew peaks of up to 50mg/l.
• Initially no gas wasinjected into the TST-CFUs, but when gaswas added to the unit,the effluent OIWconcentration stabilizedat around 2-3 mg/l.
• No additionalflocculants were usedduring this test.
• The effluent from theexisting CFU wasaround 7.8 mg/l.
Custom Process Systems29
4 52 3 2
4 53 4
1 1 2 3 2 26
4 3 2 2 2 2 2 2 2 1 2 2 2
0
10
20
30
40
50
60
mg
/lO
IW
Inlet Outlet
![Page 30: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/30.jpg)
Oil droplet size changes over the TST-CFU – D/S of the degasser
• The median (d0.5) oildroplet size changedfrom 3 to 2 μm from inlet to outlet of the TST-CFU.
• The measuredconcentration D/S theTST-CFU was very low.
• The size distribution dataand the low OIWconcentration from thislocation both indicateexcellent treatability.
• The TST-CFU removesvery small diameter oildroplets.
Custom Process Systems30
![Page 31: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/31.jpg)
Single Stage TST-CFU - D/S of 1st stage hydrocyclones
Custom Process Systems31
• The OIW resultsshow that the OIWwas reduced from~45 mg/l to 5 mg/lover one stage.
• The lowest OIWconcentration out ofthe TST-CFUwithout flocculantswas 3.5 mg/l andwith flocculants was2.5 mg/l.
• The median oildroplet size wasreduced from 3.1 to1.8μm over the TST-CFU.
![Page 32: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/32.jpg)
Single Stage TST-CFU –D/S of 2nd stage hydrocyclones
• The test wasperformed usinga single stageCFU B.
• Flocculantsimproved theOIWperformancefrom ~ 4 mg/l to~2 mg/l in theeffluent.
Custom Process Systems32
![Page 33: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/33.jpg)
33
9
5
11 12
8 911
8 8 8 79 9 9
7 8 7
10
0
5
10
15
20
25
30
35
40
45
50
mg
/lO
IW
Inlet OIW values between 850 and 1,000 mg/l
Custom Process Systems
3 Stage TST-CFU – D/S of the 1st stage Separator
• The inlet oil in waterconcentrations werebetween 850 and 1000mg/l.
• The oil in the waterfrom the 1st stageseparator containedsmall oil droplet sizewith 50% of the oildroplets < 5.7 μm.
• The first stage of theTST-CFU removed> 95 % and moved thed0.5 to 2.5 μm.
• The second and thirdstage of the TST-CFUremove a further 60%and reduce the d0.5 to2.3 μm
![Page 34: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/34.jpg)
TST-CFU – North Sea Field test Summary
• D/S of the degassing vessel – Single stage TST-CFU treated the water from an inletOIW concentration of 20 mg/l down to 2 mg/l, (90 % reduction). The existing CFU had anoutlet OIW concentration of ~7.8 mg/l, (61% OIW reduction).
• D/S of the 1st stage separator - A two stage TST CFU reduced the OIW to 20 mg/l.With subsequent treatment over a three stage TST-CFU, the effluent OIW concentrationwas reduced to 8-11 mg/l., the same level as four separate existing produced watertechnologies- flocculant vessel, hydrocyclones, degasser and existing CFU
• D/S of the 1st stage hydrocyclones - A single stage TST-CFU treated the water to anOIW concentration below that achieved by using the existing degasser and the existingCFU. With subsequent treatment over a second stage TST-CFU, the effluent OIWconcentration was further reduced by 1-2 mg/l.
• D/S of the 2nd stage hydrocyclones - A single stage TST-CFU treated the water to aconcentration down to 2 mg/l OIW, and a treatment efficiency of 90% OIW, much betterthan the level reached by using the existing degasser and the existing CFU.
Custom Process Systems34
Tie-in Points InletOIW
OIW (mg/l)Outlet 1st
stage
OIW (mg/l)Outlet 2nd
stage
OIWRemoval %
1st Stage
OIWRemoval %2nd Stage
OIWRemoval %
Total
D/S Degasser ~20 ~2 90 90
D/S 1st StageSeparator
>1000 50 20 95 60 98
D/S 1st Stage HC 50 3.5 93 93
D/S 2nd Stage HC 20 2 90 90
![Page 35: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/35.jpg)
Divider graphic should fill and notexceed the defined gray box.
Custom Process Systems35
Produced Water Treatment TrendsNext Generation Compact Flotation - TST CFU
Field Trials – North SeaField Test Results
Summary of other Field Test Results and Full Scale InstallationsConclusions and Future Work
![Page 36: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/36.jpg)
TST-CFUTM Configurations and Applications
Custom Process Systems
TST CFU 2 stages
TST CFU 1 stage
TST CFU 3 or 4 stages
![Page 37: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/37.jpg)
37
0
20
40
60
80
100
120
140
160
180
200
220
240
260
280
300
320
340
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34
Inlet
Stage 4
Pilot test results – GOM D/S of Separator
Custom process Systems
![Page 38: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/38.jpg)
3 stage CFU – South Sea China
• Outlet from Separator- 100 to 180 ppm
• Outlet from existing HC - 80 ppm
• Outlet from existing Degasser vessel - 50 ppm
Custom Process Systems38
![Page 39: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/39.jpg)
39
3 stage CFU D/S of inlet separator – South Sea China
Custom process Systems
![Page 40: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/40.jpg)
40
3 stage CFU D/S of inlet separator – South Sea China
Custom process Systems
![Page 41: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/41.jpg)
Full Scale Unit Startup 3 stage CFU – South Sea China
41
-101030507090
110130150170190210230250270290310330350370390410430450470490510530550
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Inlet
Stage 3
Custom process Systems
![Page 42: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/42.jpg)
42
3 stage CFU – China
![Page 43: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/43.jpg)
Pilot test - 4 stage CFU – China
Custom Process Systems43
0
20
40
60
80
100
120
140
160
180
200
220
240
260
280
300
320 Inlet
Stage 4
![Page 44: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/44.jpg)
Full scale unit Startup 4 stage CFU – China
44
0
50
100
150
200
250
300
350
400
450
500
550
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
Inlet CFU B
Stage 4 Outlet of CFU B
Custom process Systems
![Page 45: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/45.jpg)
Pilot test TST- WKO Water Knock Out - China
Custom Process Systems45
• Inlet to WKO – 100,000 mg/l
• Outlet from WKO - 500 mg/l
• Outlet from CFU – <20 mg/l
![Page 46: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/46.jpg)
WKO/ CFU Test Units – China
46
![Page 47: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/47.jpg)
Full Scale Startup of WKO - China
Custom Process Systems47
0
50
100
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1000
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Inlet OIW values between 80,000 and 100,000 mg/l
![Page 48: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/48.jpg)
Divider graphic should fill and notexceed the defined gray box.
Custom Process Systems48
Produced Water Treatment TrendsNext Generation Compact Flotation - TST CFU
Field Trials – North SeaField Test Results
Summary of other Field Test Results and Full Scale InstallationsConclusions and Future Work
![Page 49: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/49.jpg)
Parameters impacting performance
Oil droplet size
Important parameter for efficiency
Oil slugs
Minor effect on performance. Free oil iseasy to separate.
Gas bubble size
Smaller bubbles will give biggersurface and better contact between oildroplets and gas bubbles.
Salinity
Affects gas bubble size.
Temperature
No effect on performance, tested from250C to 950C
Pressure
No effect, tested from 0.5 to 20 bar
49 Custom process Systems
![Page 50: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/50.jpg)
50
Dissolved gas in the feedPositive effect on gas flotation
FlocculantsImproved performance with use of flocculants
Shearing across valvesShearing across upstream valves can create small oildroplets and should be avoided
Custom process Systems
Other parameters impacting performance
![Page 51: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/51.jpg)
CONCLUSIONS
Multiple separation stages within one single vessel
Can handle OIW inlet concentrations over 1,000 mg/l
No need for several vessels in series
Less space required and easier adaptation into existing installation
More flexible design
Multiple internal feed distribution instead of an external tangential inlet
Better fluid distribution and internal re-mixing
Higher probability of contact between gas bubbles and oil droplets
Not impacted by scaling up of vessels
The technology is world wide patent pending
51 Custom Process Systems
![Page 52: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/52.jpg)
CONCLUSIONS
• Better performance than traditional IGFs and conventional CFU’s
90 to 98% efficiency
• Less equipment as it can replace multiple technologies
Lower weight
Smaller footprint
• Less dependent on chemicals than the first generation CFUs
Lower OPEX
• Simple skid design
Compact single vessel option
52 Custom Process Systems
![Page 53: PWE2013 Cameron](https://reader037.vdocuments.site/reader037/viewer/2022102504/55cf9933550346d0339c253e/html5/thumbnails/53.jpg)
FUTURE WORK
• Thus far the next generation TST-CFUTM
compact flotation technology has beeninstalled at several platforms performingsatisfactorily.
• Other operating companies in the GoMand other deepwater locations are alsotesting the TST-CFUTM.
• As feedbacks from existing and new fieldinstallations are received, additionalenhancements will be made to the TST-CFUTM design.
Custom Process Systems53