Download - Project 1 Report Group 1 Wed 4 Pm
-
7/29/2019 Project 1 Report Group 1 Wed 4 Pm
1/12
Unit and student details
Unit code Unit title
If this is a group assignment, each student must include their name and ID number and sign the student statement.
Student ID Surname Given names
Student ID Surname Given names
Student ID Surname Given names
Student ID Surname Given names
Assignment details
Title of assignment Authorised group assignment Yes No
Lecturer/tutor Tutorial day and time
Due date Date submitted
Submission date and extensionsAll work must be submitted by the due date. If an extension of work is granted this must be authorised on this form with tsignature of the lecturer or tutor.
Extension granted until
Lecture/tutor Signature
Plagiarism and collusion
Intentional plagiarism amounts to cheating in terms of Monash Statute 4.1 Discipline. For further information see tuniversitys Plagiarism policy including details of penalties and information about the plagiarism register.
Plagiarism - Plagiarism means to take and use another persons ideas and/or manner of expressing themselves and
pass these off as ones own, failing to give appropriate acknowledgement. This includes material from any source, stastudents or the internet - published and unpublished works.
Collusion - Collusion is unauthorised collaboration with another person or persons.
Penalties - If there are reasonable grounds for believing that intentional plagiarism or collusion has occurred, this will reported to the Chief Examiner, who may disallow the work concerned by prohibiting assessment or refer the matter to thFaculty Manager.
Student statement and signature
I have read the universitys statement on cheating and plagiarism, as described in the Student Resource Guide
This assignment is original and has not previously been submitted as part of another unit/subject/course
I have taken proper care of safeguarding this work and made all reasonable effort to ensure it could not be copied
I acknowledge that the assessor of this assignment may for the purposes of assessment, reproduce the assignmeand:- provide it to another member of faculty
I understand the consequences for engaging in plagiarism as described in Statute 4.1. Part III Academic Misconduct
I certify that I have not plagiarised the work of others or participated in unauthorised collusion when preparing thassignment.
Student signature Date
Student signature Date
Student signature Date
Student signature Date
Please note that it is your responsibility to retain a copy of your assignment
Privacy Statement
Assessment cover shee
ENG 1020 Engineering Structures
24428817 Yeap Ci Qing
23732288 Hendrata Kristian
v
AlMansari Ahmed23848138
24735124 ShivaNarayan
Lim Pooi Mee
26/04/2013 24/04/2013
Tuesday, 16.00
Kristian Hendrata
Yeap Ci Qing
Ahmed Almansari
Shiva Narayan
24/04/2013
24/04/2013
24/04/2013
24/04/2013
Project 1 : Truss Design Report
-
7/29/2019 Project 1 Report Group 1 Wed 4 Pm
2/12
ENG1020 ENGINEERING STRUCTURE
Monash University Sunway Campus
Department of Civil Engineering
Truss Design Report
Group assignment
Name: Ahmed AlMansari ID: 23848138
Name: Kristian Hendrata ID: 23732288
Name: Shiva Narayan ID: 24735124
Name: Matthew Yeap Ci Qing ID: 24428817
Tutor : Lim Pooi Mee
Session : Tuesday, 16.00-18.00
Submission dates: 23 April 2013
-
7/29/2019 Project 1 Report Group 1 Wed 4 Pm
3/12
SummaryThis is a report of the design of a truss for the pedestrian bridge. The bridges will be
constructed across the new highway between Monash University Sunway Campus and the
Western Carpark. Two designs will be shown, one of them is initial design, which is an
assumption and another is an optimized final design.
Firstly, the geometry of the truss will be shown with all estimated loadings, for instance, dead
loads, live loads and wind loading for initial design to initialize the calculation. Afterwards,
the analysis of truss will describe how the estimated design loads will be allocated, how
much external reactions at the contact point with ground will be generated and how muchinternal forces at each members will exist. Lastly, is a full detailed failure check on yielding
and buckling of critical members. With all the data collected, optimisation was performed to
find a material with enough support and least resources for the truss design.
In short, this report wills demonstrates the main features of the support of the bridge in three
areas, which are geometry, analysis and optimization of the truss. This report will show that
the final size of SHS 20x20x1.6 is suitable to support the bridge and using the least materials. !!
!!!!
-
7/29/2019 Project 1 Report Group 1 Wed 4 Pm
4/12
Table&of&Contents&
Summary. ii
1.0$Introduction!..........................................................................................................................!1$1.1$Problems$and$Limitation$for$the$application !..........................................................................!1$
1.2$Background$of$the$truss !..............................................................................................................!1$2.0$The$Geometry$of$Truss!.......................................................................................................!1$2.1$Assumption$of$the$pedestrian$bridge !.......................................................................................!1$2.1.1$Dead$Loads$..............................................................................................................................................$2 $2.1.2$Live$Load$..................................................................................................................................................$2 $2.1.3$Wind$Load$...............................................................................................................................................$3 $
2.2$Design$of$Trusses!..........................................................................................................................!3$
3.0$Analysis$of$truss!...................................................................................................................!5$3.1$Allocation$of$the$loads !.................................................................................................................!5$3.2$Reactions$of$the$truss !...................................................................................................................!5$3.3$Internal$forces$of$each$members !...............................................................................................!6$
4.0$Optimization$of$The$Truss!.................................................................................................!7$4.1$Failure$checking !............................................................................................................................!7$4.2$Optimization!..................................................................................................................................!7$
5.0$Conclusions!...........................................................................................................................!7$
6.0$References!.............................................................................................................................!8$
$$$$$$$Appendices$
Appendix AGeometry of the bridgeAppendix B Loadings of all estimated dead, live and wind loads
Appendix C Load Paths and Supports
Appendix D Truss AnalysisAppendix E Failure checking and OptimisationAppendix F Final Design
-
7/29/2019 Project 1 Report Group 1 Wed 4 Pm
5/12
1
1.0 Introduction
1.1 Problems and Limitation for the application
An opportunity has come, a new pedestrian bridge, in between Monash University and theWestern Carpark, is on demand. The bridge has to span over twenty meters across the new
highway and link our fellow students to their cars. To avoid the truss towers to be built too closeto the highway, a tolerance of four meters for the bridge should be given if the width of truss is
smaller than one meter. Meanwhile, overhead walkway should height over five meters but notover designed, so that trucks can pass by and users will not be tortured. Also the majority of
drivers in campus at the moment appear to be stand around average Asian, obesity is also not thatpopular around the campus, thus a height of two and a half meters by width of two meters
walkway can be expected. Since the major objective is to design the truss, materials beyondtrusses will be over designed and might not be suitable for real application. These are the major
concerns of the team when decisions were made.
1.2 Background of the truss
Truss is a framework of stone or timber, typically consisting of rafters, posts, and struts,supporting a roof, bridge, or other structure, usually consisting of triangular units (Lindberg &
Stevenson, 2010). In this application, four trusses are to be form a truss tower and support thepedestrian bridge and all of them have the identical design. The truss is the one that takes the
most static loading among other trusses. Furthermore, the ratio of the width and height of a trussshould range between 1:10 to 1:20.
2.0 The Geometry of Truss
2.1 Assumption of the pedestrian bridge
First of all, dimensions of the bridge are decided under the limitation defined in the introduction.Length of the bridge is twenty-four meters, with a width of two meters and stand five meters
high from ground level. The walkway of the bridge has two and a half meters height to allowmost pedestrian pass by. Advertising board will be equipped on each side of truss towers. For
detailed drawings please refers to Appendix A. In addition, assumptions of loads support bytrusses were made to initialize the calculation. Typically the calculation of loads will be products
of quantities and specific mass in term of kilo newton. However, the values of assumptions areslightly exaggerated and have not been optimized, so that designed trusses will not easily fail in
real application. For instance the loads are dead loads, live load and wind load. Moreover, theloads were applied with magnification factor to satisfy Ultimate Limit State (ULS) of the trusses
to reduce the chance of collapse (Department of Civil Engineering, 2001). Detailed calculationsand references of properties are performed in Appendix B.
-
7/29/2019 Project 1 Report Group 1 Wed 4 Pm
6/12
2
Figure 1. Front view of the bridge.
The major logical thinking behind the calculations of loads is below:
2.1.1 Dead Loads
Dead loads are weight of components that are fixed with the bridge and will be carried by
the trusses. The domain includes the loads of roof, roof frames, frames of advertising board(AD), floor, trusses, lamps and handrails. A list of the properties of the dead loads is prepared as
following:Weight of roof : 4.58kg/m
2
Weight of roof frames : 12kg/mWeight of AD frames : 5.56kg/m
Weight of floor : 28kg/m2
Weight of trusses : 10kg/m
Weight of lighting : 1.2kg per lampWeight of handrails : 3.10kg/m
During detailed calculation, each of them is expressed in term of kilo newton (kN) andmultiplied with their corresponding quantities. However, please note that loads of trusses are
initialized, as 10kg/m, but the value will be reassigned after optimization. Additionally, the loadsof trusses and frames of advertising board will be refer later in Method of Joints and Method of
Section instead of allocation of loads.
2.1.2 Live Load
At the moment, the bridge is designed exclusively for pedestrians only.
Weight of pedestrian : 100kg per person
Occupancy of people : 4 person per meter squareAreas of the floor : 48m
2
The total live loads will be multiplier of the given predictions and areas can be occupied, the
same logic as the calculation of dead loads. Total loads of both dead and live loads aresummarized in table 1 , exclude the loads of trusses and frames of advertising board.
-
7/29/2019 Project 1 Report Group 1 Wed 4 Pm
7/12
3
Items Loads (kN) ULS (kN)Roof 2.1984 2.638Roof frame 26.04 31.248Floor 13.44 16.128Lighting 0.2880 0.3456Handrail 1.488 1.786Live Loads 192 288TOTAL 235.454 340.145Table 1. Loads beyond the trusses, for detailed calculation please refers to Appendix B.
2.1.3 Wind Load
In this case, the wind load was designed to blow only from a horizontal direction to create a
worst-case scenario. However the wind load was not factored with any standard. Wind load will
be applied on advertising boards and pushes truss tower from the sides with fewer loadsallocated to the sides with more loads. This load path is important to make sure the wind doesn'taffect the structures stability. In this report, the load carried by the wind was assumed to be:
Wind pressures : 0.5 kPaAreas of a advertising board : 2.5 m
2
Wind loads on a advertising board : 1.25kN
2.2 Design of Trusses
The geometries of the truss were determined by limitation mentioned earlier in the introduction
such as trucks should be able to pass the bridge. The height of truss towers is five meters, and the
width of truss is half a meter to make sure the ratio of width and height is between 1:10 to 1:20.Angles between diagonal and horizontal members are designed to be forty-five degrees, so thatlength of vertical members is identical with horizontal members. Also directions of diagonal
members will alternate between forty-five and one hundred and thirty five degrees. At groundlevel, one side of the truss is hinged and another is roller. Figure 2 presents the side view of a
truss.
-
7/29/2019 Project 1 Report Group 1 Wed 4 Pm
8/12
4
Figure 2. Side view of the truss, all dimensions in mm
The stability of the design can be determined using the following equation:
m + r = 2jm : member of the truss
r: number of external reactionsj: number of joint in structure
m + r = 2j Stable Determinate
m + r > 2j Stable Indeterminate
m + r < 2j Unstable Undefined
-
7/29/2019 Project 1 Report Group 1 Wed 4 Pm
9/12
5
From figure 2, (41) + (3) = 2(22), which is left hand side equals to right hand side. Thus the trusswill be stable and determinate.
3.0 Analysis of truss
3.1 Allocation of the loads
Figure 3. Top view of the bridge, all dimensions in mm.
All of the loads collected in section 2.1 will be treated as UDL to simplify the question. So the
loads will be divided according to the areas of each joints take part. In addition, a truss towerconsists of four trusses, eight joints in total. On the other hand, each two joints of the eight joints
are extremely close to each other, which means the team can take it as sixteen quadrilaterals andthen halve the values into two joints of that area. The result of allocation is shown as figure 3.
The highest value will be thirty-one and twenty two hundredth kilo newton and the highest value
of adjacent joints is ten and four hundreds and eight thousandth kilo newton. Go to Appendix Cfor detailed calculations.
3.2 Reactions of the truss
The truss with highest value of allocated loads is examined. constructed with the approximatevalue of loads and forces on each truss members. The structure will undergo a bending moment,
but the design truss will then apply the equilibrium bending moment equation in order to balanceback the force generated by the wind and cancel out the forces to achieve the stable structure.
The three state of equilibrium of the structure was described using the equations stated below:
Fx = 0 shows an equilibrium on x-axisFy = 0 shows an equilibrium on y-axisM = 0 shows an equilibrium for the moment from any point
Reactions:Ry1 = -9.008kN
Rx1 = 0.6250kN
Ry2 = 36.07kN
-
7/29/2019 Project 1 Report Group 1 Wed 4 Pm
10/12
6
3.3 Internal forces of each members
The internal forces will be calculated by Method of joints and checked by Method of section andreactions. Sum of forces in x and y direction will equals to zeros was used to find all the internal
forces of every member joints by joints, while method of sections was used to check thecalculation. Bear in mind that the self-weight of the truss is distributed to each joint according
the length of trusses around the joints. In defense of the team, although it cost a little more effortsto do that, calculations standing on a solid foundation are increasing our faith on the result.
Detailed calculations available in Appendix D.For vertical members:
Highest compression : 35.807kNFor diagonal members:
Highest tension : 0.905kNHighest compression : 0.751kN
Figure 4. Internal Forces Diagram, all dimensions in kN.
-
7/29/2019 Project 1 Report Group 1 Wed 4 Pm
11/12
7
4.0 Optimization of The Truss
4.1 Failure checkingProperties of SHS 65x65x6.0
Yielding Stress : 350MPa
Buckling Force : 5574kNActual and design Stress for highest tension and compression member is needed. The conditionof not failing is the actual stress smaller than the design stress. Both yielding and buckling is
checked with the dimension of SHS 65x65x6.0 using P=F/A and F = 2EI/L
2.
Actual Stress and Force
Compression Yielding Stress : 27.76 MPaTension Yielding Stress : 0.702 MPa
Buckling Force : 35.807 kNThe result appears to be a pass. All detailed calculations in this section are in Appendix E.
4.2 OptimizationOptimization is similar with failure checking, same equations were applied just that differentvariables that varies. The value of maximum compression is then used and manipulated in the
buckling and yielding equation to get the minimum gross section area and moment of inertia, Ivalue of the truss. The value of maximum tension is also used in the yielding equation to get the
minimum gross section area. Using the values from previous calculation, the team can getmaximum three ranges in table of section hollow size. Choose the sizes that include all three sets
with the least mass, it will be a better materials that have enough supports and fewer mass.Beware that vertical and diagonal members require different sizes, which means two times of
comparing and choosing. Use the new values and redo section 2.1.1, 3.0 and 4.0 until new valuesequals to the old values. It will be wise to let programs to do it for the team. All detailed
calculations in this section are in Appendix E&F.Equations:
Amin = Fmax/PImin = FmaxL
2/
2E
Result :
Highest Amin = 105.3mm2
Highest Imin = 0.004535 x 106mm
4
5.0 Conclusions
In conclusion, after repeated calculation, the team found that the best sizes of the truss membersfor the bridge will be SHS 20x20x1.6 and the members intermediate the bridge and at the ground
level were most heavily loaded. .
-
7/29/2019 Project 1 Report Group 1 Wed 4 Pm
12/12
8
6. ReferencesLindberg, C. A., & Stevenson, A. (Eds.). (2010). New Oxford American Dictionary (3
ed.). Oxford University Press.Department of Civil Engineering. (2001). ENG1020 Engineering Structure Study Guide.