Locked rotor torque
Pull up torque
Break down torque
Full load torque
2
-
7/30/2019 Operating Characteristics of Induction Motor Revised
3/31
3
-
7/30/2019 Operating Characteristics of Induction Motor Revised
4/31
4
-
7/30/2019 Operating Characteristics of Induction Motor Revised
5/31
5
-
7/30/2019 Operating Characteristics of Induction Motor Revised
6/31
6
-
7/30/2019 Operating Characteristics of Induction Motor Revised
7/317
When the resistance of the rotor bars are loweredthe pullout torque comes closer to synchronousspeed
-
7/30/2019 Operating Characteristics of Induction Motor Revised
8/318
-
7/30/2019 Operating Characteristics of Induction Motor Revised
9/31
High efficiency at normal operating conditions requires a low rotorresistance. On the other hand, a high rotor resistance is required to produce a
high starting torque and to keep the magnitude of the starting currentlow and the power factor high.
The wound rotor is one way of meeting the above mentioned need for
varying the rotor resistance at different operating conditions. Wound-rotor motors are, however, more expensive than squirrel-cagemotors.
.
Effect of the rotorresistance
the torque-slipcurves
-
7/30/2019 Operating Characteristics of Induction Motor Revised
10/31
10
-
7/30/2019 Operating Characteristics of Induction Motor Revised
11/31
Following double squirrel-cage arrangements can also be used toobtained a high value of effective resistance at starting and a low value ofthe resistance at full-load operation.
It consists of two layers of bars, both short-circuited by end rings.
The upper bars are small in cross-section and have a high resistance.
They are placed near the rotor surface so that the leakage flux sees a pathof high reluctance; consequently, they have a low leakage inductance.
The lower bars have a large cross-section, a lower resistance and a highleakage inductance.
Double squirrel-cage rotor bars
-
7/30/2019 Operating Characteristics of Induction Motor Revised
12/31
At starting, rotor frequency is high and very little current flows throughthe lower bars; the effective resistance of the rotor is then the highresistance upper bars.
At normal low slip operation, leakage reactance are negligible, and therotor current flows largely through the low resistance lower bars; the
effective rotor resistance is equal to that of the two sets of bars in parallel.
Double squirrel-cage rotor bars
-
7/30/2019 Operating Characteristics of Induction Motor Revised
13/31
The use of deep, narrow rotor barsproduces torque-slip characteristicssimilar to those of a double-cage rotor.
Leakage inductance of the top cross-section of the rotor bar is relatively low;
the lower sections have progressivelyhigher leakage inductance.
At starting, due to the high rotorfrequency, the current is concentratedtowards the top layers of the rotor bar.
At full-load operation, the currentdistribution becomes uniform and theeffective resistance is low.
-
7/30/2019 Operating Characteristics of Induction Motor Revised
14/31
At low slip rotor frequency is low therefore lessleakage reactance allow to conduct currentduring running
At high slips reactance are large compared to
resistance so the current is forced through thebars at surface which reactance is lowcompared to deeper bars.
These conductors closer to surface have higherresistance
A high torque at starting could be obtained
14
-
7/30/2019 Operating Characteristics of Induction Motor Revised
15/31
15
-
7/30/2019 Operating Characteristics of Induction Motor Revised
16/31
Class A
Standard motor design
Full load torque and pull out torque occurs at
low values of slip High inrush currents 500% to 800% rated
current
Applications-fans , blowers , pumps etc.
16
-
7/30/2019 Operating Characteristics of Induction Motor Revised
17/31
Class B
Normal starting torque
Same starting torque as class A
Applications are similar to class A
17
-
7/30/2019 Operating Characteristics of Induction Motor Revised
18/31
Class C
Has high starting torque
Double cage motors
Applicationsneed high starting torque like
compressors and conveyors
18
-
7/30/2019 Operating Characteristics of Induction Motor Revised
19/31
Class D
Very high starting torque
Pullout torque occurs at low slip
Used for high inertia loads like fly wheels andpunch press
19
-
7/30/2019 Operating Characteristics of Induction Motor Revised
20/31
20
-
7/30/2019 Operating Characteristics of Induction Motor Revised
21/31
Why need a starting mechanism?
21
-
7/30/2019 Operating Characteristics of Induction Motor Revised
22/31
Direct On Line/Full Voltage starting/Acrossthe line starting
Star Delta
Auto-Transformer Primary Resistance Reduced Voltage
Rotor Resistance
Electronic Soft Start
22
-
7/30/2019 Operating Characteristics of Induction Motor Revised
23/31
apply full line voltage to themotor upon starting
when the high startingcurrent does not affect the
power supply system andthe machinery will standthe high starting torque
manual or magnetic. When the supply voltage
fails, the motor will stopand restart automaticallywhen supply isrestored(manual)
23
Double Pole manualStarter
Three pole manual
starter
-
7/30/2019 Operating Characteristics of Induction Motor Revised
24/31
Unlike themanual starterin which thepower contactsare closedmanually ,themagneticstarter motor
starter contactsare closed byenergizing aholding coil.
24
-
7/30/2019 Operating Characteristics of Induction Motor Revised
25/31
25
Resistors inserted into theprimary of the motor increasethe overall impedance of thecircuit and reduce the starting
current. In effect the voltagedrop across the resistors givesa reduced voltage to the motorterminals. While reducing thecurrent, we should alsoremember that the torque willalso be reduced. than for astar-delta starter
-
7/30/2019 Operating Characteristics of Induction Motor Revised
26/31
the transformer is connected instar (-KM1) and the linecontactor (-KM2) closed. Thisapplies a reduced voltage forthe initial starting of the motor.
when the motor has reached fullspeed the auto-transformer starcontactor (-KM1) is opened.This momentarily places thetransformer in-line with themotor (as an inductance), untilstep 3 is complete.
the line contractor (-KM3) isclosed putting the line voltageonto the motor and the auto-transformer isolated bycontactor (-KM2) opening.
26
-
7/30/2019 Operating Characteristics of Induction Motor Revised
27/31
27
KM1 is initiallyclosed to put themotor in starconfiguration sametime KM2 also closed
At the end of startingKM1 is opened and
KM# is closed toplace the windings indelta
-
7/30/2019 Operating Characteristics of Induction Motor Revised
28/31
Soft starters use acombination ofpower electronicsand electroniccontrol circuitryto slow increasethe voltage on themotor duringstarting; ensuinga smoothacceleration.
28
Spikes atreducevoltagestart
Voltagelimiting
Currentlimiting
-
7/30/2019 Operating Characteristics of Induction Motor Revised
29/31
Electronic soft starters contain the thyristors controlthe firing
Modern soft starters can set varying start and stop
ramps, setting of the initial starting voltage, currentlimiting control and thermal overload protection.firing of thyristors other than a zero voltage (current)will create a non-linear load characteristic
29
-
7/30/2019 Operating Characteristics of Induction Motor Revised
30/31
Soft start
Current limit start
Full-voltage start
Linear speed acceleration
Preset slow speed
Soft Stop
30
-