INTRODUCTION
CONTENTS
US SYSTEM
REFERENCE
Osstem Implant 2014-15 Comprehensive Catalog
Overall Planning/Editing PR Department Design Team
Supervision Implant Lab, Marketing PM
Production/Distribution Marketing & Planning Team
Date of Publication 2014.
Publisher Osstem Implant
8th FL, World Meridian II, 123, Gasan digital 2-ro,
Geumcheon-gu, Seoul, Korea
Phone +82.2.2016.7000
Fax +82.2.2016.7001
www.osstem.com
"Osstem - FutureTechnology and
Superior Quality"Products that dentists can trust.
That is the mission of Osstem Implant.
We deeply appreciate all of our customers
who use our products.
We deeply appreciate all of our customers who use our products.With population aging, rising incomes, and increased interest in healthand aesthetics, implants have become an essential treatment indentistry around the world.Today, implants are well-known as a safe and effective treatmentoption, and the leading treatment option for patients with no teeth.To satisfy this global trend, Osstem has invested heavily in R&D andcontinuously promotes innovative products, resulting in it becoming aglobal leader in technology and product quality.Osstem is releasing new products including TSIII CA, TSIII BA, SSIIIHA, and MS SA, and is strengthening its product line-up in order toenable application in a variety of clinical cases. Other products to bereleased that will enable safe, easy implant procedures includeSMARTbuilder, AutoBone collector, 123 KIT, and ESSET KIT.
TSIII CA in particular is expected to become a leading product in theglobal implant market after launching as a groundbreaking product withsuperior hydrophilic properties capable of at least 30% greater fusionthan ordinary SA products due to its calcium ion solution encapsulation.Also, to improve our customers' convenience and foster reasonablepurchasing, we have opened an online store, DenALL (www.denall.com),where dentistry materials can be purchased affordably and conveniently.Osstem leads the way in superior product quality and exports to over50 countries including the USA, China, Japan, Germany, and India, andis the first company in Korea to record implant sales of over 30 millionproducts and overseas subsidiary sales of over 100 billion won.
Osstem Implant CEOGyu-ok Choi (DDS, Ph.D)
20062006 ssia (Moscow)ssia (MoRusRus
( (Esch (Esc )hborn)
20112011 zakhstan (Almaty)maty)zakhstan (Almaty)KazK
2011201111 BanBangladeshglgla h (Dhaka)(Dh )ei)n (Taipeanwaan (Tanwaaa )ei)Taipe )i)T in (Tanwa (TaTaiwTaiwTaiwT i
2006
20062006
20132013320101 ey (Isrkey (Istanbul)ul)key (Tuur 1997
2011
2006
2007 Australia (SSydney)
2011 nada (Vancouver)Ca
2006 aUSA (Philadelphia)delphia)hia)
201120 exico (Guadalajara)exico (GuadMeMe
12
01 OSSTEM Co., Ltd.Founded
Launched "Doobunae"(health insurance claimingsoftware)
10
06 Launched "Hanaro"(dentistry managementsoftware)
Acquired Korean companySumin ComprehensiveDental Materials
199701 Obtained CE-0434
certification
03 Established AICTraining Center
200103 Changed company name to
Osstem Implant Co., Ltd.
04 Obtained GOST-Rcertification in Russia
12 Established the firstincorporation stage ofoverseas subsidiaries in 12countries
200602 Listed on KOSDAQ
stock exchange andbegan trading
06 Obtained GOST-Rcertification in Russia
12 Selected next-generation productsObtained certificationfrom Australia'sTherapeutic GoodsAdministration
200701 Established Osstem's
osteology researchcenter
12 Selected as a NationalStrategic LeadingTechnology Company
200803 Launched TSIII SA implant
06 Launched TSIII HA implant
08 Selected as WPMBiomedical National PolicyCompany
12 Exceeded 10,000 dentistrysoftware members
2010
10 Obtained permissionfrom Japan's Ministry ofHealth, Labor, andWelfare to produce andsell medical devices
200905 Selected as a WorldClass
300 business
2014
06 Selected Osstem ImplantResearch Center as an ATC(Superior TechnologyResearch Center)
07 Selected as a worldchampion business
10 Obtained Health Canadacertification
12 Launched K2 unit chairSelected as "Global First-Class Product"
201101 Launched Osstem's
xenograft "A-Oss"09 Launched K3 unit chair
10 Selected as a hiddenchampion business
2013
06 Launched TSIII CA implant
07 Established Osstem MedicalEquipment Research Center
2012
200001 Established Osstem
Implant Research Center
08 Obtained US FDAcertificationLaunched USII implant
10 Launched SSII implant
2002
Osstem Implant,the leader in popularizing implants in Korea!
We stand out with our passion for strategic
R&D and best products, creating globally
trend-setting implants.
Submerged type implant with an Internal hex 11taper connection structure
Connection type and color - Mini/Regular
Highest initial stability in soft bone by using upper-section small thread
Corkscrew thread & cutting edge- Easy path adjustment through a superior self-threading
effect- Acquires insertion torque with an increase in soft bone
initial stability and without deviation according to thedrill diameters
The various body shape options are available accordingto the bone and patient's clinical condition- TSII (straight body): Easily adjustable insertion depth- TSIII (1.5 taper body): Able to acquire the initial stability
needed for immediate loading even in soft bone- TSIV (6 taper body): Able to acquire superior initial
stability only in maxillary sinus and soft bone
Applied Surface - SA/CA/BA/HA
Packaging Color Information for Each System
Non-submerged type implant with anInternal octa 8 taper connectionstructure based on one-time procedures
Connection type and color - Regular/Wide
Corkscrew thread & cutting edge- Easy path adjustment through a superior self-threading
effect- Acquires insertion torque with an increase in soft bone
initial stability and without deviation according to thedrill diameters
The various body shape options are available accordingto the bone and patient's clinical condition- SSII (straight body): Easily adjustable insertion depth- SSIII (1.5 taper body): Able to acquire the initial stability
needed for immediate loading even in soft bone
Applied Surface - SA/CA/HA
Submerged type implant with an external hexconnection structure
Connection type and color- Mini/Regular/Wide/Wide PS
Corkscrew thread & cutting edge- Easy path adjustment through a superior self-threading
effect- Acquires insertion torque with an increase in soft bone
initial stability and without deviation according to thedrill diameters
The various body shape options are available accordingto the bone and patient's clinical condition- USII (straight body): Easily adjustable insertion depth- USIII (1.5 taper body): Able to acquire the initial stability
needed for immediate loading even in soft bone- USIV (6 taper body): Able to acquire superior initial
stability only in maxillary sinus and soft bone
Applied Surface - SA
US SYSTEM Contents
016USII SAFixture
018USIII SAFixture
020USIV SAFixture
022SimpleMount
022CoverScrew
022 023 025CementAbutment
028 030
031 032 033 034 035FixtureTransferImpressionCoping
036Fixture LabAnalog
036UCLAPolishingProtector
037SmartFitAbutment
038 039
040 044EstheticAbutment
045 045 045
046 046046EstheticPick-upImpressionCoping
047EstheticLabAnalog
047
048 049 049 049 050Esthetic-lowTemporaryCylinder
AngledAbutment
UCLAGoldAbutment
EstheticGoldCylinder
EstheticPlasticCylinder
EstheticTemporaryCylinder
EstheticTransferImpressionCoping
Esthetic-lowAbutment
Esthetic-low GoldCylinder
Esthetic-lowPlasticCylinder
Esthetic-low HealingCap
ZioCeraAngledAbutment
EstheticPolishingProtector
HeadlessCoverScrew
HealingAbutment
UCLANP-CastAbutment
UCLAPlasticAbutment
FixturePick-UpImpressionCoping
ZioCeraAbutment
SafeAbutment
EstheticHealingCap
UCLATemporaryAbutment
057057StandardPick-upImpressionCoping
057 057StandardPolishingProtector
StandardLabAnalog
050050Esthetic-low Pick-upImpressionCoping
051 051Esthetic-lowPolishingProtector
052MultiAngledAbutment
055StandardAbutment
056StandardHealingCap
056 056 056StandardTemporaryCylinder
Esthetic-low LabAnalog
Esthetic-lowTransferImpressionCoping
EstheticPlasticCylinder
059O-ring Abutment
060O-ringRetainerCap Set
060O-ringRetainerSet
060O-ring Set
061LocatorAbutment
062LocatorMaleProcessingKit
062LocatorReplacementMale
062LocatorExtendedReplacementMale
063LocatorBlackProcessingMale
063LocatorBlock OutSpacers
063LocatorImpressionCoping
063LocatorLab Analog
064LocatorCore Tool
064LocatorTorqueDriver
StandardGoldCylinder
StandardTransferImpressionCoping
060O-ring Lab Analog
FIXTURE COMPONENTS016018020022022022023
USII SA Fixture
USIII SA Fixture
USIV SA Fixture
Simple Mount
Cover Screw
Headless Cover Screw
Healing Abutment
024025028030031032033037038039040042044048052054055058059061
PROSTHETIC FLOW DIAGRAM 1
Cement Abutment
Angled Abutment
UCLA Gold Abutment
UCLA NP-Cast Abutment
UCLA Plastic Abutment
UCLA Temporary Abutment
SmartFit Abutment
ZioCera Abutment
ZioCera Angled Abutment
Safe Abutment
PROSTHETIC FLOW DIAGRAM 2
Esthetic Abutment
Esthetic-low Abutment
Multi Angled Abutment
PROSTHETIC FLOW DIAGRAM 3
Standard Abutment
PROSTHETIC FLOW DIAGRAM 4
O-ring Abutment
Locator Abutment
016
L
Hex 1.2
L 8.5 10 11.5 13
US2M3508S US2M3510S US2M3511S US2M3513S
L 8.5 107 11.5 13
US2S4008SUS2S4007S US2S4010S US2S4011S US2S4013S
L 8.5 107 11.5 13
US2S4508SUS2S4507S US2S4510S US2S4511S US2S4513S
D Ø3.5P Ø3.5Hex 2.4
D Ø4.0P Ø4.1Hex 2.7
D Ø4.5P Ø4.1Hex 2.7
USII SA Fixture
Submerged type implant with external hex connection structure
Optimum screw thread design for optimum SA surface
Straight body design for easy adjustment of insertion depth
Powerful self-threading effect using corkscrew thread
Recommended insertion torque : 40Ncm 이하
※ In single implant cases for posterior region, use of fixture at least 4.5mm
in diameter is recommended
NoMount fixture order code
: fixture product code (ex : US2R4010S)
Pre-Mounted fixture order code (fixture + mount + cover screw)
: A + fixture product code (ex : AUS2R4010S)
017
PS
L 8.5 1076 11.5 13
US2W5008SUS2W5007SUS2W5006S US2W5010S US2W5011S US2W5013S
L 8.5 1076 11.5 13
US2P5008SUS2P5007SUS2P5006S US2P5010S US2P5011S US2P5013S
D Ø5.0P Ø5.1Hex 3.4
D Ø5.0P Ø5.0Hex 2.7
Short
Short
D
018 019
L
Hex 1.2
L 8.5 10 11.5 13
US3M3508S US3M3510S US3M3511S US3M3513S
L 8.5 107 11.5 13
US3R4008SUS3R4007S US3R4010S US3R4011S US3R4013S
L 8.5 107 11.5 13
US3R4508SUS3R4507S US3R4510S US3R4511S US3R4513S
D Ø3.5P Ø3.5Hex 2.4
D Ø4.0P Ø4.1Hex 2.7
D Ø4.5P Ø4.1Hex 2.7
L 8.5 1076 11.5 13
US3W5008SUS3W5007SUS3W5006S US3W5010S US3W5011S US3W5013S
L 8.5 1076 11.5 13
US3P5008SUS3P5007SUS3P5006S US3P5010S US3P5011S US3P5013S
D Ø5.0P Ø5.1Hex 3.4
D Ø5.0P Ø5.0Hex 2.7
Short
L 8.5 1076 11.5 13
US3W6008SUS3W6007SUS3W6006S US3W6010S US3W6011S US3W6013S
D Ø6.0P Ø5.1Hex 3.4
Short
L 8.5 1076 11.5 13
US3W7008SUS3W7007SUS3W7006S US3W7010S US3W7011S US3W7013S
D Ø7.0P Ø5.1Hex 3.4
Short
Ultra-wide
USIII SA Fixture
Submerged type implant with external hex connection structure
Optimum screw thread design for optimum SA surface
Taper body design with superior initial stability
Powerful self-threading effect using corkscrew thread
Acquires the initial stability needed in immediate loading even in soft bone
Ultra-wide
In implant cases for posterior tooth extraction and immediate insertion, this
fixture is useful in exchanging a failed implant
With its optimized apex design, capable of extracting a tooth and obtaining
initial stability safely even at the bottom 3mm
Recommended insertion torque : 40Ncm 이하
※ In single implant cases for posterior region, use of fixture at least 4.5mm in
diameter is recommended
NoMount fixture order code
: fixture product code (ex : US3R4010S)
Pre-Mounted fixture order code (fixture + mount + cover screw)
: A + fixture product code (ex : AUS3R4010S)
Short
PS
D
020 021
USIV SA Fixture
Submerged type implant with external hex connection structure
Optimum screw thread design for optimum SA surface
Fixture for use only in maxillary sinus and soft bone
Powerful self-threading effect using corkscrew thread
Due to sharp apex design, even after D4 bone Ø2.0, Ø3.0mm drilling
implant insertion is possible
Recommended insertion torque : 40Ncm 이하
※ In single implant cases for posterior region, use of fixture at least 4.5mm
in diameter is recommended
※ USIV fixture insertion is recommended at 15 rpm or lower due to large
thread pitch and high insertion speed
NoMount fixture order code (fixture + mount + cover screw)
: fixture product code (ex : US4R4010S)
Pre-Mounted fixture order code (fixture + mount + cover screw)
: A + fixture product code (ex : AUS4R4010S)
L
Hex 1.2
L 8.5 107 11.5 13
US4R4008SUS4R4007S US4R4010S US4R4011S US4R4013S
L 8.5 107 11.5 13
US4R4508SUS4R4507S US4R4510S US4R4511S US4R4513S
L 8.5 107 11.5 13
US4W5008SUS4W5007S US4W5010S US4W5011S US4W5013S
D Ø4.0P Ø4.1Hex 2.7
D Ø4.5P Ø4.1Hex 2.7
D Ø5.0P Ø5.1Hex 3.4
L 8.5 107 11.5 13
US4P5008SUS4P5007S US4P5010S US4P5011S US4P5013S
D Ø5.0P Ø5.0Hex 2.7
PS
D
022 023
USHAMM
AICM100 AICR100 AICW100 TICW100
D
H
1.1
1.1
USHAMR
USHAMW
HCM100 HCR100 HCW100
Simple Mount
Hex driver : 1.2Recommended tightening torque : 8~10NcmPacking unit : mount + mount screw C = Connection
Mount & Screw
C
CCover Screw
Hex driver : 0.9(mini), 1.2(regular/wide)Recommended tightening torque : 5~8NcmC = Connection
CHeadless Cover Screw
Used when adjacent space is l imited or there is
insufficient gum tissue in the suture area
Hex driver : 0.9(mini), 1.2(regular/wide)Recommended tightening torque : 5~8NcmC = Connection
Healing Abutment
Hex driver : 1.2Recommended tightening torque : 5~8Ncm
D H
Ø 4.0Ø 5.0
AIHM503
AIHM505
-
-
-
-
AIHM403
AIHM405
-
-
2.0 3.0 5.5 7.04.0
D H
Ø 4.1 One Piece
Ø 4.1 Two Piece
Ø 5.0Ø 6.0
AIOHR405
AIHR405
AIHR505
AIHR605
AIOHR407
AIHR407
AIHR507
AIHR607
AIOHR403
AIHR403
AIHR503
AIHR603
-
-
AIHR502
AIHR602
2.0 3.0 5.5 7.0
-
-
AIHR504
AIHR604
4.0
D H
Ø 5.1 One Piece
Ø 5.1 Two Piece
Ø 6.0Ø 7.0Ø 6.0 PS
AIOHW505
AIHW505
AIHW605
AIHW705
TIHW605
-
-
-
-
-
AIOHW503
AIHW503
AIHW603
AIHW703
TIHW603
-
-
AIHW602
AIHW702
2.0 3.0 5.5 7.0
-
-
AIHW604
AIHW704
4.0
Fixture level
PS
Fixture Transfer Impression Coping
Non-HexHexShort
Fixture Pick-up Impression Coping
Long
025024
Non-HexHex
UCLA TemporaryAbutment
Ti Screw
UCLA Polishing Protector(Only UCLA Abutment)
CementAbutment
Double Hex Hex
AngledAbutment
Non-HexHexNon-HexHex
UCLA PlasticAbutment
Fixture Lab Analog
ZioCera (Angled)Abutment
SmartFitAbutment
Non-HexHexNon-Hex
UCLA Gold/NP-CastAbutment
Hex
SafeAbutment
PROSTHETIC FLOW DIAGRAM 1
Cement / Angled / UCLA / SmartFit /ZioCera / Safe
Cover Screw
022p
Healing Abutment
1.2 Hex Driver
023p
025p
025p 028p 030/031p 032p
036p
034p 035p
036p
033p 037p 038/039p 040p
Fixture Level Impression
Cement Abutment
Ti screw: USABSMT
D Ø4.0
- CAM427 -
G/HHType
7.0
7.0
1.0 2.0 3.0
CAM447
4.0Hex
- CAM427N -
1.0 2.0 3.0
CAM447N
4.0Non-Hex
Used in producing ordinary cement type prosthetics
Gold coloring on gingiva region for aesthetics
1.2 hex driver
Recommended tightening torque : 30 Ncm
Packing unit : abutment + Ti screw
Abutment + Ti screw order code
: product code + TH (ex : CAR525TH) Ti screw
H
G/H
D
Ti screw: ASR200
D Ø4.1
- - CAR437
Type1.0 2.0 3.0
-
4.0Hex
- - CAR437N
1.0 2.0 3.0
-
4.0Non-Hex
1.2 Hex Driver(Mini Only : 0.9 Hex Driver)
Fixture level
H G/H
USII SA
016p
USIII SA
018p
USIV SA
020p
026 027
Ti screw: ASR200
D Ø5.0
CAR514
CAR515
CAR517
CAR524
CAR525
CAR527
CAR534
CAR535
CAR537
Type
4.05.57.0
1.0 2.0 3.0
CAR544
CAR545
CAR547
4.0Hex
CAR514N
CAR515N
CAR517N
CAR524N
CAR525N
CAR527N
CAR534N
CAR535N
CAR537N
1.0 2.0 3.0
CAR544N
CAR545N
CAR547N
4.0Non-Hex
Ti screw: ASR200
D Ø6.0
CAR615 CAR625 CAR635
Type
5.5
1.0 2.0 3.0
CAR645 CAR615N CAR625N CAR635N CAR645N
4.0Hex
1.0 2.0 3.0 4.0Non-Hex
Ti screw: ASW0200
D Ø6.0
CAW614
CAW615
CAW617
CAW624
CAW625
CAW627
CAW634
CAW635
CAW637
Type
4.05.57.0
1.0 2.0 3.0
CAW644
CAW645
CAW647
4.0Hex
CAW614N
CAW615N
CAW617N
CAW624N
CAW625N
CAW627N
CAW634N
CAW635N
CAW637N
1.0 2.0 3.0
CAW644N
CAW645N
CAW647N
4.0Non-Hex
Ti screw: ASW200
D Ø5.1
- - CAW537
Type
7.0
1.0 2.0 3.0
- - CAW537N -
4.0Hex
1.0 2.0 3.0 4.0Non-Hex
Ti screw: ASW200
D Ø7.0
CAW715 CAW725 CAW735
Type
5.5
1.0 2.0 3.0
CAW745 CAW715N CAW725N CAW735N CAW745N
4.0Hex
1.0 2.0 3.0 4.0Non-Hex
Ti screw: ASR200
D Ø6.0
- TCAW627 -
Type
7.0
1.0 2.0 3.0
TCAW647 - TCAW627N - TCAW647N
4.0Hex
1.0 2.0 3.0 4.0Non-Hex
Ti screw: RASW200
D Ø6.0
- RCAW627 -
TypeR-type
7.0
1.0 2.0 3.0
RCAW647
4.0Hex
Cement Abutment
PS
H G/H H G/H
H G/H
H G/H
H G/H
H G/H
H G/H
029028
Angled Abutment
AAM4152C AAM4154C AAM4252C AAM4254C
Used when adjusting path of prosthetic is necessary
Through double hex connection, abutment direction limit is
overcome
1.2 hex driver
Recommended tightening torque : Ti screw 30Ncm
Packing unit : abutment + Ti screw
Abutment + Ti screw order code
: product code + TH (ex : AAR5152CTH) Ti screwG/H
12
D
Ti screw: USABSMT
D Ø4.0 G/HAngle
4.02.015°
4.02.025°
AAR5152C AAR5154C AAR5252C AAR5254C
Ti screw: ASR200
D Ø5.0 G/HAngle
4.02.015°
4.02.025°
TAAW6152C TAAW6154C TAAW6252C TAAW6254C
Ti screw: ASR200
D Ø6.0 G/HAngle
4.02.015°
4.02.025°
RAAW6152C RAAW6154C RAAW6252C RAAW6254C
Ti screw: RASW200
D Ø6.0 G/HAngle
4.02.015°
4.02.025°
AAW6152C AAW6154C AAW6252C AAW6254C
Ti screw: ASW200
D Ø6.0 G/HAngle
4.02.015°
4.02.025°
R-type
PS
Fixture level
030 031
Used when path, aesthetics, or space have limitations
Prosthetic must be produced by casting dental-grade gold alloy
Abutment region fusion range : 1400。C~1450。C
(casting with non-precious metal alloys is incompatible)
1.2 hex driver
Recommended tightening torque : Ti screw 30 Ncm
Packing unit : abutment + Ti screw
Abutment + Ti screw order code
: product code + TH (ex : GCR200TH)
UCLA Gold Abutment
D
Ti screw
GCM200 GCM100
Ti screw: USABSMT
D Ø4.0 Type Non-HexHex
GCR200 GCR100
Ti screw: ASR200
D Ø4.5 Type Non-HexHex
GCW200 GCW100
Ti screw: ASW200
D Ø5.5 Type Non-HexHex
TGCW200 TGCW100
Ti screw: ASR200
D Ø5.5 Type Non-HexHex
RGCW200 RGCW100
Ti screw: RASW200
D Ø6.0 Type Non-HexHex
12
Used when path, aesthetics, or space have limitations
Prosthetic production by casting with dental-grade non-precious
metal alloy
Abutment region fusion range : 1400。C~1550。C
1.2 hex driver
Recommended tightening torque : 30 Ncm
Packing unit : abutment + Ti screw
Abutment + Ti screw order code
: product code + TH (ex : NCR200TH)
UCLA NP-Cast Abutment
D
Ti screw
NCM200 NCM100
Ti screw: USABSMT
D Ø4.0 Type Non-HexHex
NCR200 NCR100
Ti Screw: ASR200
D Ø4.5 Type Non-HexHex
NCW200 NCW100
Ti screw: ASR200
D Ø5.5 Type Non-HexHex
TNCW200 TNCW100
Ti screw: ASR200
D Ø5.5 Type Non-HexHex
12
PS
R-type
PS
Fixture level Fixture level
032 033
Used when path, aesthetics, or space have limitations
Prosthetic production by casting with dental-grade alloy
(gold, non-precious metals)
Connection region's precision is reduced compared to
UCLA gold abutment
1.2 hex driver
Recommended tightening torque : 30 Ncm
Packing unit : abutment + Ti screw
Abutment + Ti screw order code
: product code + TH (ex : PSR200TH)
UCLA Plastic Abutment
D
Ti screw
PSM200 PSM100
Ti screw: USABSMT
D Ø4.0 Type Non-HexHex
PSR200 PSR100
Ti screw: ASR200
D Ø4.5 Type Non-HexHex
PSW200 PSW100
Ti screw: ASW200
D Ø5.5 Type Non-HexHex
TPSW200 TPSW100
Ti screw: ASR200
D Ø5.5 Type Non-HexHex
RPSW200 RPSW100
Ti screw: RASW200
D Ø6.0 Type Non-HexHex
12
Used in producing temporary prosthetics (Material: Ti Gr-3)
Structure enabling easy customization and minimizing indication
restrictions
1.2 hex driver
Recommended tightening torque : 20 Ncm
Packing unit : abutment + Ti screw
Abutment + Ti screw order code
: product code + TH (ex : TAR200TH)
UCLA Temporary Abutment
D
Ti screw
TAM200 TAM100
Ti screw: USABSMT
D Ø4.0 Type Non-HexHex
TAR200 TAR100
Ti screw: ASR200
D Ø4.5 Type Non-HexHex
TAW200 TAW100
Ti screw: ASW200
D Ø5.5 Type Non-HexHex
TTAW200 TTAW100
Ti screw: ASR200
D Ø5.5 Type Non-HexHex
RTAW200 RTAW100
Ti screw: RASW200
D Ø6.0 Type Non-HexHex
12
PS
R-type
PS
R-type
Fixture level Fixture level
035034
UCLA Abutment Components
ICPM402L
ICPR502L
ICPW602L
TICPW602
RICPW602
ICPM401L
ICPR501L
ICPW601L
TICPW601
RICPW601
13.5Hex Non-Hex
D LType
Ø 4.0Ø 5.0Ø 6.0Ø 6.0 PS
Ø 6.0 R-type
ICPM402S
ICPR502S
ICPW602S
-
-
ICPM401S
ICPR501S
ICPW601S
-
-
10.5Hex Non-Hex
Fixture Transfer Impression Coping
Takes impression using closed tray
Increased popularity after creating impression with gemstone-shaped structure ( )
1.2 hex driver
Packing unit : hex - impression coping + guide pin
non-hex - impression coping
-
CSR100
-
CSW100
-
-
CSM150
CSR150*
-
CSW150*
TCSW150
RCSW150
-
CSR170
-
-
-
-
D LType
Ø 4.0Ø 5.0Ø 6.0Ø 6.0Ø 6.0 PS
Ø 6.0 R-type
-
ICSR500
-
ICSW600
-
-
-
ICSR500N
-
ICSW600N
-
-
7 10 1715Guide Pin
Hex Non-Hex
ICFM400
ICFR500
ICFR600
ICFW600
TICFW600
RICFW600
ICFM400N
ICFR500N
ICFR600N
ICFW600N
TICFW600N
RICFW600N
12Hex Non-Hex
Fixture Pick-Up Impression Coping
Takes impression using open tray
Superior impression stability with holinone structure
1.2 hex driver
* Label is basic packaging specification
Packing unit : impression coping body + guide pin
036 037
SmartFit Abutment
CAD/CAM abutment
1.2 hex driver
Recommended tightening torque : 20Ncm(mini), 30Ncm(regular)
Recommended clinical case
- Case where implant insertion area or angle is incorrect (max 30°)
- Multiple cases requiring consistent path and stable support
- Anterior case where aesthetic design is required
- Irregular or exceedingly deep gingiva case
How to Order
- Create order sheet
- Send necessary items for each case to Osstem Implant CAD/CAM center
- Working time : 5~7days
UCLA Abutment Components
Fixture Lab Analog
Achieves fixture in oral cavity on a working model
FAM300
FAR300
FAW300
TFAW300
RFAM300
C
UCLA Polishing Protector
Used to prevent damage to connection part when
polishing after casting a prosthetic
UPCM100
UPCR100
UPCW100
TUPCW100
RUPCW100
C
PS
R-type
PS
R-type
038 039
ZioCera Abutment
Zirconia material with superior biocompatibility
Advantageous in aesthetic prosthetics due to having similar color
with natural teeth
1.2 hex driver
Recommended tightening torque : Ti screw 30Ncm
Packing unit : abutment + Ti screw
Abutment + Ti screw order code
: product code + TH (ex : ZAR537TH)
Ti screw
G/H
H
D
ZAM5377.0 ZAM557
Ti screw: ASM200
D Ø5.0 G/HH 5.03.0
ZAR5377.0 ZAR557
Ti screw: ASR200
D Ø5.0 G/HH 5.03.0
ZAR6377.0 ZAR657
Ti screw: ASR200
D Ø6.0 G/HH 5.03.0
ZioCera Angled Abutment
Used in producing aesthetic prosthetics with significant path
adjustment
Advantageous in aesthetic prosthetics due to having similar
color with natural teeth
Capable of screw restoration through direct build-up
1.2 hex driver
Recommended tightening torque : 30Ncm(regular)
Packing unit : abutment + Ti screw
Abutment + Ti screw order code
: product code + TH (ex : ZAAR5173TH)Fixture levelFixture level
G/H
D
H
17°
ZAAR51739.0
Ti screw: ASR200
D Ø5.5 G/HH 3.0
9.0 ZAAR6173
Ti screw: ASR200
D Ø6.5 G/HH 5.0
Ti screw
041040
G / H
H
SFAR514SC
SFAR515SC
SFAR517SC
4.05.57.0
SFAR544SC
SFAR545SC
SFAR547SC
D Ø4.8 G/HH 4.01.0
SFAR524SC
SFAR525SC
SFAR527SC
2.5
SFAW614SC
SFAW615SC4.05.5
SFAW644SC
SFAW645SC
D Ø6.0 G/HH 4.01.0
SFAW624SC
SFAW625SC
2.5
Used in producing single prosthetics for preventing screw
loosening
Prevents rotation of prosthetic with elliptical abutment body
Gold coloring on gingiva region for aesthetics
1.2 hex driver
Recommended tightening torque : 30Ncm
Packing unit : abutment + Ti screw + carrier cap + protect cap
Safe Abutment
D
Fixture level
043042
PROSTHETIC FLOW DIAGRAM 2
Esthetic / Esthetic-low / Multi Angled
045p
046p 045p
047p
046p
044p
046p
045p
047p
045p
Abutment Level Impression
Ti Screw
2.0 Int.Hex Driver (Regular) Esthetic Healing Cap
Esthetic TransferImpression Coping
EstheticPolishing Protector
EstheticLab Analog
Esthetic Abutment Screw
EstheticTemporary Cylinder
EstheticGold Cylinder
EstheticPlastic Cylinder
Non-HexHex
Non-HexHex Non-HexHex Non-HexHex
Esthetic Pick-up Impression Coping
Esthetic Abutment(Regular Only)
049p
050p 049p
051p
050p
048p 052p
050p
049p
051p
049p
Ti Screw
2.0 Int.Hex Driver (Regular)
2.7 Int.Hex Driver (Wide)Esthetic-low
AbutmentMulti Angled
AbutmentEsthetic-low Healing Cap
Esthetic-low TransferImpression Coping
Esthetic-lowPolishing Protector
Esthetic-lowLab Analog
Esthetic-low Abutment Screw
Esthetic-lowTemporary Cylinder
Esthetic-lowGold Cylinder
Esthetic-lowPlastic Cylinder
Non-HexHex
Non-HexHex Non-HexHex Non-HexHex
Esthetic-low Pick-upImpression Coping
Cover Screw
022p
Healing Abutment
023p
USII SA
016p
USIII SA
018p
USIV SA
020p
Cover Screw
022p
Healing Abutment
023p
USII SA
016p
USIII SA
018p
USIV SA
020p
1.2 Hex Driver1.2 Hex Driver(Mini Only : 0.9 Hex Driver)
1.2 Hex Driver1.2 Hex Driver(Mini Only : 0.9 Hex Driver)
045044
G/H
1.8
D
EAR100 EAR400
D Ø4.8 G/H 4.01.0
EAR300
3.0
EAR200
2.0
Used in producing screw-retained aesthetic prosthetics
Structure producing prosthetics in cylinder after attaching
abutment in the oral cavity
Compensates the path up to 30°
2.0 internal hex driver (241p)
Recommended tightening torque : 30Ncm
Packing unit : abutment + Ti screw
Abutment + Ti screw order code
: product code + TH (ex : EAR200TH)
Esthetic Abutment
Fixture level
12
12
Esthetic Abutment Components
Esthetic Healing Cap
Used when protecting aesthetic-low abutment in the oral cavity
and minimizing foreign body sensation in patient
1.2 hex driver
Recommended tightening torque : 20Ncm
EHC100
6.0D H
Ø 4.8
Esthetic Gold Cylinder
Prosthetic must be produced by casting dental-grade gold alloy
Cylinder region fusion range : 1400。C~1450。C
(casting with non-precious metal alloys is incompatible)
1.2 hex driver
Recommended tightening torque : 20Ncm
Packing unit : cylinder + Ti screw
Cylinder + Ti screw order Code
: product code + TH (ex : EGC200TH)
EGC200 EGC100
Hex Non-HexD Type
Ø 4.8Ti screw: TS200
Esthetic Plastic Cylinder
Produces prosthetics by casting with dental-grade alloy
(gold, non-precious metals)
Connection region's precision is reduced compared to
gold cylinder
1.2 hex driver
Recommended tightening torque : 20Ncm
Packing unit : cylinder + Ti screw
Cylinder + Ti Screw order code
: product code + TH (ex : ETT200TH)
EPS200 EPS100
Hex Non-HexD Type
Ø 4.8Ti screw: TS200
046 047
Esthetic Temporary Cylinder
Used in producing temporary prosthetic with aesthetic
abutment (Material: Ti Gr-3)
Structure allows for easy customization and
minimization of indication constraints
1.2 hex driver
Recommended tightening torque : 20Ncm
Packing unit : cylinder + Ti screw
Cylinder + Ti screw order code
: product code + TH (ex : ETT200TH)
ETT200 ETT100
Hex Non-HexD Type
Ø 4.8Ti screw: TS200
Esthetic Transfer Impression Coping
Takes impression using closed tray
ETR100
8.0D H
Ø 4.8
D L
Ø 4.8 ESR200 ESR100
Hex Non-Hex
Esthetic Pick-up Impression Coping
Takes impression using open tray
Superior impression stability with holinone structure
* Label is basic packaging specification
Packing unit : impression coping body + guide pin
GP100 GP150* GP170
10 17
GP200
2015Guide Pin
12
Esthetic Abutment Components
Esthetic Lab Analog
Achieves aesthetic abutment of the oral cavity on a
working model
ERR300
D
Ø 4.8
Esthetic Polishing Protector
Used with the goal of preventing damage to the connection
area of cylinder when polishing after casting the prosthetic
EPCR100
D
Ø 4.8
048 049
Esthetic-low Abutment
Used when gap between opposing teeth is
lower than aesthetic abutment
Path compensation up to 48。
2.0(regular), 2.7(wide) internal hex driver (241p)
Recommended tightening torque : 30Ncm
Packing unit : abutment + Ti screw
Abutment + Ti screw order code
: product code + TH (ex : MER200TH)
D
G/H
MER100 MER400
D Ø4.8 G/H 4.01.0
MER300
3.0
MER200
2.0
MEW100 MEW400
D Ø5.5 G/H 4.01.0
MEW300
3.0
MEW200
2.0
TMEW100 TMEW400
D Ø5.5 G/H 4.01.0
TMEW300
3.0
TMEW200
2.0PS
Fixture level
Esthetic-low Healing Cap
Used when protecting aesthetic-low abutment in the oral
cavity and minimizing foreign body sensation in patient
1.2 hex driver
Recommended tightening torque : 20NcmMHCR100
MHCW100
6.0D H
Ø 4.8Ø 5.5/Ø 5.5 PS
Esthetic-low Gold Cylinder
Prosthetic must be produced by casting dental-grade
gold alloy
Cylinder region fusion range : 1400。C~1450。C
(casting with non-precious metal alloys is incompatible)
1.2 hex driver
Recommended tightening torque : 20Ncm
Packing unit : cylinder + Ti screw
Cylinder + Ti screw order code
: product code + TH (ex : MGR200TH)
MGR200
MGW200
MGR100
MGW100
Hex Non-HexD Type
Ø 4.8Ø 5.5/Ø 5.5 PS
Ti screw: MTS200 (Ø 4.8): WTS200 (Ø 5.5 /Ø 5.5PS)
Esthetic-low Plastic Cylinder
Prosthetic production by casting with dental-grade alloy
(gold, non-precious metals) after customization
Lower precision in connection area compared to gold cylinder
1.2 hex driver
Recommended tightening torque : 20Ncm
Packing unit : cylinder + Ti screw
Cylinder + Ti screw order code
: Product code + TH (ex : MEPR200TH)
MEPR200
MEPW200
MEPR100
MEPW100
Hex Non-HexD Type
Ø 4.8Ø 5.5/Ø 5.5 PS
Ti screw: MTS200 (Ø 4.8): WTS200 (Ø 5.5 /Ø 5.5PS)
12
12
050 051
Esthetic-low Abutment Components
Esthetic-low Temporary Cylinder
Used in producing temporary prosthetics (Material: Ti Gr-3)
Structure enabling easy customization and minimizing
indication restrictions
1.2 hex driver
Recommended tightening torque : 20Ncm
Packing unit : cylinder + Ti screw
Cylinder + Ti screw order code
: product code + TH (ex : MTR200TH)
MTR200
MTW200
MTR100
MTW100
Hex Non-HexD Type
Ø 4.8Ø 5.5/Ø 5.5 PS
Ti screw: MTS200 (Ø 4.8): WTS200 (Ø 5.5 /Ø 5.5PS)
Esthetic-low Transfer Impression Coping
Takes impression using closed tray
Ø 4.8Ø 5.5/Ø 5.5 PS
Ø 4.8Ø 5.5/Ø 5.5 PS
MTTR100
MTTW100
8.0D H
D L
MSR200
MSW200
MSR100
MSW100
Hex Non-Hex
Esthetic-low Pick-up Impression Coping
Takes impression using open tray
Superior impression stability with holinone structure
*Label is basic packaging specification
Packing unit : impression coping body + guide pin
GP100
GPW100
GP150*
GPW150*
GP170
-
10 17
GP200
-
2015Guide Pin
12
Esthetic-low Lab Analog
Achieves aesthetic abutment of the oral cavity on a
working model
MERR300
MERW300
D
Ø 4.8Ø 5.5/Ø 5.5 PS
Esthetic-low Polishing Protector
Used with the goal of preventing damage to the
connection area of cylinder when polishing after casting
the prosthetic
MPCR100
MPCW100
D
Ø 4.8Ø 5.5/Ø 5.5 PS
052 053
Multi Angled Abutment
Used in implant path compensation in screw retained multiple case
Up to 60。path compensation (two implant standard)
Prosthetic production using US aesthetic-low cylinder(non-hex)
Recommended tightening torque : 20Ncm(mini), 30Ncm(regular)
Packing unit : multi angled abutment + Ti screw
Abutment + Ti screw order code
: product code + TH (ex : US17MAR4830TH)Fixture level
G/H
A
D
Ti screw
Ti screw: USMABSM
D Ø4.8
US17MAM4820 US17MAM4830 -
H/GAngle
2.0 3.0 4.0
- - -
3.0 4.0 5.017。 30。
Ti screw: USMABSR
D Ø4.8
US17MAR4820 US17MAR4830 US17MAR4840
H/GAngle
2.0 3.0 4.0
US30MAR4830 US30MAR4840 US30MAR4850
3.0 4.0 5.017。 30。
055054
PROSTHETIC FLOW DIAGRAM 3
Standard
056p
056p 056
057p057p
057p 057p
056p
056p
Abutment Level Impression
Ti Screw
2.0 Int.Hex Driver (Regular)
2.7 Int.Hex Driver (Wide)Standard Abutment
(Regular Only)
Standard Healing Cap
Standard Abutment Screw
Standard Temporary Cylinder
Standard Polishing Protector
Standard LabAnalog
Standard Gold Cylinder Standard Plastic Cylinder
Standard Pick-upImpression Coping
Standard TransferImpression Coping
Standard Abutment
Used in producing bridge prosthetics when requiring
hybrid type denture or hygiene management
Advantageous in oral hygiene after producing prosthetic
along gum line
2.0 internal hex driver (241p)
Recommended tightening torque : 30Ncm
Packing unit : abutment + Ti screw
Abutment + Ti screw order code
: product code + TH (ex : SAR300TH)
D
H
SAR300 SAR850
D Ø4.5 G/H 8.5
SAR700
7.03.0
SAR550
5.5
SAR400
4.0
Fixture level
Cover Screw
022p
Healing Abutment
023p
USII SA
016p
USIII SA
018p
USIV SA
020p
055p
1.2 Hex Driver1.2 Hex Driver(Mini Only : 0.9 Hex Driver)
057056
Standard Abutment Components
Standard Healing Cap
Used when protecting standard abutment in the oral cavity
and minimizing foreign body sensation in patient
1.2 hex driver
Recommended tightening torque : 20Ncm SHC100
3.5D H
Ø 4.5
Standard Gold Cylinder
Prosthetic must be produced by casting dental-grade gold alloy
Cylinder region fusion range : 1400。C~1450。C
(casting with non-precious metal alloys is incompatible)
1.2 hex driver
Recommended tightening torque : 20Ncm
Packing unit : cylinder + EbonyGold screw
Cylinder + EbonyGold screw order code
: product code + WH (ex : SGC300WH)
SGC300 SGC400
11 12D H
Ø 4.5Ti screw: TS200W (Ø 4.5)
Esthetic Plastic Cylinder
Recommended tightening torque : 20Ncm
1.2 hex driver
Prosthetic production by casting with dental-grade alloy
(gold, non-precious metals)
Lower precision in connection area compared to gold cylinder
Packing unit : cylinder + Ti screw
Cylinder + Ti screw order code
: product code + TH (ex : SPS100TH)
SPS100
12D H
Ø 4.5Ti screw: TS200 (Ø 4.5)
Standard Temporary Cylinder
Used in producing temporary prosthetic with standard
abutment (Material: Ti Gr-3)
Structure enabling easy customization and minimizing
indication restrictions
1.2 hex driver
Recommended tightening torque : 20Ncm
Packing unit : cylinder + Ti screw
Cylinder + Ti screw order code
: product code + TH (ex : SPS100TH)
STT100
12D H
Ø 4.5Ti screw: TS200 (Ø 4.5)
Standard Transfer Impression Coping
Takes impression using closed tray
STR100
8.0D H
Ø 4.5
Standard Lab Analog
Achieves standard abutment of the oral cavity on a working
model
SPR300
D
Ø 4.5
Standard Polishing Protector
Used with the goal of preventing damage to the connection
area of cylinder when polishing after casting the prosthetic
SPCR100
D
Ø 4.5
D L
Ø 4.5 SSR100
8.0
Standard Pick-up Impression Coping
Takes impression using open tray
Superior impression stability with holinone structure
*Label is basic packaging specification
Packing unit : impression coping body + guide pin
GP100 GP150* GP170
10 17
GP200
2015Guide Pin
058 059
PROSTHETIC FLOW DIAGRAM 4
O-ring / LocatorOverdenture
O-ring Lab Analog
Locator Impression Coping
Locator Lab Analog
O-ring Abutment Driver
O-ring
Cap Type
Open Type
O-ring System
Spacer & Male Cap
Male Extended Male
Multi Tool
O-ring Abutment Locator Abutment Locator Torque Driver
059p
063p
063p
061p
060p
060p 060p
064p
064p
O-ring Abutment
Used in creating stud type overdenture prosthetics
Compensates the path up to 20。
Uses O-ring abutment driver (AORD)
Recommended tightening torque : 30Ncm
D
G/H
3.4
G/H 2.0 4.03.0 5.0 6.0
OAA200 OAA300 OAA400 OAA500 OAA600
G/H 2.0 4.03.0 5.0 6.0
OAAW200 OAAW300 OAAW400 OAAW500 OAAW600
D Ø5.0
D Ø5.6
Fixture level
063p
062p 062p
Cover Screw
022p
Healing Abutment
023p
USII SA
016p
USIII SA
018p
USIV SA
020p
1.2 Hex Driver1.2 Hex Driver(Mini Only : 0.9 Hex Driver)
060 061
O-ring Abutment Components
Achieves low vertical dimension, stability, and various attachments
with retention
Possible path compensation up to40。(two implant standard)
Tightening by using a locator torque driver
Recommended tightening torque : 30Ncm
Locator Abutment
D
1.5
G/H
G/H 1.0 3.02.0 4.0 5.0
HULCA3510M HULCA3520M HULCA3530M HULCA3540M HULCA3550M
D Ø3.5
G/H 1.0 3.02.0 4.0 5.0
HULCA4010R HULCA4020R HULCA4030R HULCA4040R HULCA4050R
D Ø4.1
G/H 1.0 3.02.0 4.0 5.0
HULCA5010W HULCA5020W HULCA5030W HULCA5040W HULCA5050W
D Ø5.0
Fixture level
OAL
RS01
O-ring Retainer Set
Advantageous when occlusal clearance is low
compared to retainer cap
Packing unit : retainer + o-ring
O-ring Lab Analog
Achieves O-ring abutment of the oral cavity on a
working model
RCS01
O-ring Retainer Cap Set
Used in creating stud type overdenture prosthetics
Packing unit : retainer cap + o-ring
OAON01S
O-ring Set
Packing unit : 5ea
062 063
Locator Abutment Components
LMPS
LRM06S
LRM12S
LRM22S
Locator Male Processing Kit
Component
- Block out spacer / denture cap connected black
processing male
- Replacement male blue/pink/clear
Used after selecting retention males that are appropriate
for the case
Exchanged with male using a locator core tool
Packing unit : 2set
Locator Replacement Male
Retention: Approximately 6N
0。~20。paths (two implant standard)
Packing unit : blue replacement male 4ea
Retention: Approximately 12N
0。~20。paths (two implant standard)
Packing unit : pink replacement male 4ea
Retention: Approximately 22N
0。~20。paths (two implant standard)
Packing unit : clear replacement male 4ea
Locator Extended Replacement Male
Retention: Approximately 6N
20。~40。paths (two implant standard)
Packing unit : red extended replacement male 4ea
Retention: Approximately 12N
20。~40。paths (two implant standard)
Packing unit : green extended replacement male 4ea
LEM06S
LEM12S
Locator Black Processing Male
Used in lab. process
Packing unit : 4ea
LBPS
Locator Block Out Spacers
Gap sealing component between denture cap and abutment
Packing unit : 20ea
LBSS
Locator Impression Coping
Used in taking impressions after attaching locator abutment
Packing unit : 4ea
LICS
Locator Lab Analog
Achieves locator abutment on the model
Packing unit : 4ea
LAL40S
065064
Locator Abutment Components
TWLDSK TWLDLK
Locator Core Tool
Used in attaching and changing replacement males
LCCT
Short LongLocator Torque Driver
Used in locator abutment tightening
Type
067066
Osstem Implant Key References
Clinic
No. Title Reference / Author
1 Retrospective clinical study of new tapered design implantsin maxillary posterior areas
Oral Biology Research. 2013; 37(2):105-111
/ Young-Kyun Kim et al.16 Evaluation of sinus bone resorption and marginal bone loss after
sinus bone grafting and implant placementOral Surg Oral Med Oral Pathol Oral Radiol
Endod. 2009;107:e21-8
/ Young-Kyun Kim et al.
17 Evaluation of peri-implant tissue response according to thepresence of keratinized mucosa
Oral Surg Oral Med Oral Pathol OralRadiol
Endod. 2009;107:e24-8
/ Young-Kyun Kim et al.
18 Study on radiographic evaluation of marginal bone loss aroundosseonintegrated implant after functional loading
J Kor Oral Maxillofac Surg. 2009;35:240-7
/ Young - Deok, Chee
19 Four-year survival rate of RBM surface internal connection non-submerged implants and the change of the peri-implant crestal bone
J Korean Assoc Maxillofac Plast Reconstr
Surg. 2009;31(3):237-42
/ Sok-Min Ko et al.
2 A randomized controlled clinical trial of two types of tapered implantson immediate loading in the posterior maxilla and mandible
Int J Oral Maxillofac Implants.
2013 Nov-Dec;28(6):1602-11 (IF 1.908)
/ Young-Kyun Kim et al.
3 Bony window repositioning without using a barrier membranein the lateral approach for maxillary sinus bone grafts:clinical and radiologic results at 6 months.
Int J Oral Maxillofac Implants.
2012 27:211-217
/ Chang-Joo Park et al.
4 A relaxed implant bed: implants placed after two weeks ofosteotomy with immediate loading: a one year clinical trial.
J Oral Implantol. 2012 Apr;38(2):155-64
/ Bansal J et al.
5 A multicenter prospective study in type IV bone of a singletype of implant
Implant Dent. 2012 Aug;21(4):330-34
/ Su-Gwan Kim et al.
6 Comparison of clinical outcomes of sinus bone graft with simultaneousimplant placement: 4-month and 6-month final prosthetic loading
Oral Surg Oral Med Oral Pathol Oral Radiol
Endod. 2011 Feb;111(2):164-9
/ Young-Kyun Kim et al.
7 Prospective study of tapered resorbable blasting media surfaceimplant stability in the maxillary posterior area
Oral Surg Oral Med Oral Pathol Oral Radiol
Endod. 2012 Feb 28. [Epub ahead of print]
/ Young-Kyun Kim et al.
8 A 1-year prospective clinical study of soft tissue conditions and marginalbone changes around dental implants after flapless implant surgery
Oral Surg Oral Med Oral Pathol Oral Radiol
Endod. 2011 Jan;111(1):41-6
/ Byung-Ho Choi et al.
9 Evaluation of peri-implant tissue in nonsubmerged dentalImplants:a multicenter retrospective study
Clin Implant Dent Relat Res.
2011 Dec;13(4):324-9
/ Young-Kyun Kim et al.
Biology
No. Title Reference / Author
1 Experiment study of bone response to hydroxyapatite coatingimplants: bone-implant contact and removal torque test
Oral Surg Oral Med Oral Pathol Oral Radiol.
2012 Jun 29. [Epub ahead of print]
/ Young-Kyun Kim et al.
2 Experimental study about the bony healing of hydroxyapatitecoating implants
J Kor Oral Maxillofac Surg.
2011;27(4):295-300
/ Young-Kyun Kim et al.
3 The use of autologous venous blood for maxillary sinus flooraugmentation in conjunction with sinus membrane elevation: anexperimental study
Clin. Oral Impl. Res. 2010;21:346-9
/ Byung-Ho Choi et al.
4 Effects of soft tissue punch size on the healing of peri-Implanttissue in flapless implant surgery
Oral Surg Oral Med Oral Pathol Oral Radiol
Endod. 2010;109:525-30
/ Byung-Ho Choi et al.
5 Morphogenesis of the peri-implant mucosa: a comparison betweenflap and flapless procedures in the canine mandible
Oral Surg Oral Med Oral Pathol Oral Radiol
Endod. 2009;107:66-70
/ Byung-Ho Choi et al.
6 A comparative study of two noninvasive techniques to evaluateimplant stability: periotest and osstell mentor
Oral Surg Oral Med Oral Pathol Oral Radiol
Endod. 2009;107:513-8
/ Su-Gwan Kim et al.
7 Influence of abutment connections and plaque control on the initialhealing of prematurely exposed implants: an experimental study in dogs
J Periodontol. 2008;79(6):1070-4
/ Byung-Ho Choi et al.
8 Er:YAG laser irradiated implant surface observation with scanningelectron microscopy
J Korean Assoc Maxillofac Plast Reconstr
Surg. 2008;30(6):540-5
/ Seung-Ki Min et al.
9 The effect of surface treatment of the cervical area of implant onbone regeneration in mini-pig
J Kor Oral Maxillofac Surg. 2008;34:285-92
/ Hong-Ju Park et al.
10 A relaxed implant bed: implants placed after two weeks of osteotomywith immediate loading: a one year clinical trial
J Oral Implantol. 2012 Apr;38(2):155-64
/ Bansal J et al.
11 A comparison of implant stability quotients measured usingmagnetic resonance frequency analysis from two directions:prospective clinical study during the initial healing period
Clin. Oral Impl. Res. 2010;21(6):591-7
/ Jong-Ho Lee et al.
12 A short-term clinical study of marginal bone level change aroundmicrothreaded and platform-switched implants
J Periodontal Implant Sci. 2011;41:211-217
/ Kyoo-Sung Cho et al.
13 A randomized clinical one-year trial comparing two types ofnonsubmerged dental implant
Clin. Oral Impl. Res. 2010;21(2):228-36
/ Jong-Ho Lee et al.
14 Short-term, multi-center prospective clinical study of short implantsmeasuring less than 7mm
J Kor Dent Sci. 2010;3(1):11-6
/ Young-Kyun Kim et al.
15 Evaluation of peri-implant tissue in nonsubmerged dentalImplants:a multicenter retrospective study
Oral Surg Oral Med Oral Pathol Oral Radiol
Endod. 2009;108(2):189-95
/ Young-Kyun Kim et al.
069068
10 Histologic and histomorphometric evaluation of early andimmediately loaded implants in the dog mandible
J Biomed Mater Res A. 2008;86:1122-7
/ Su-Gwan Kim et al.
11 Effects of different depths of gap on healing of surgically createdcoronal defects around implants in dogs: a pilot study
J Periodontol. 2008;79(2):355-61
/ June-Sung Shim et al.
12 Comparative study of removal effect on artificial plaque from RBMtreated implant
J Korean Assoc Maxillofac Plast Reconstr
Surg. 2007;29(4):309-20
/ Hee-Jyun Oh et al.
Biomechanics
No. Title Reference / Author
1 Evaluation of the correlation between insertion torque andprimary stabilityof dental implants using a block bone test
J Periodontal Implant Sci. 2013;43:41-46
/ Ki-Tae Koo et al.
2 Self-cutting blades and their influence on primary stability oftapered dental implants in a simulated low-density bone model:a laboratory study
Oral Surg Oral Med Oral Pathol Oral Radiol
Endod. 2011;112:573-580
/ Young-Jun Lim et al.
3 Variation in the total lengths of abutment/implant assemblies generatedwith a function of applied tightening torque in external and internalimplant-abutment connection
Clin. Oral Impl. Res. 2011;22:834-9
/ Ki-Seong Kim et al.
4 Effect of impression coping and implant angulation on the accuracyof implant impressions: an in vitro study
J Adv Prosthodont. 2010;2(4):128-33
/ Seung-Geun Ahn et al.
5 Influence of implant diameter and length changes on initial stability J Kor Acad Prosthodont. 2009;47:335-41
/ Chang-Mo Jeong et al.
6 Mechanical strength of zirconia abutment in implant restoration J KASFO. 2009;25(4):349-60
/ Young-Chan Jeon et al.
7 Heat transfer to the implant-bone interface during preparation ofzirconia/alumina complex abutment
Int J Oral Maxillofac Implants.
2009;24(4):679-83
/ Yong-Geun Choi et al.
8 Fatigue fracture of different dental Implant system under cyclic loading J Kor Acad Prosthodont.
2009;47(4):424-34
/ In-Ho Cho et al.
9 Effect of tightening torque on abutment-fixture joint stability using3-dimensional finite element analysis
J Kor Acad Prosthodont.
2009;47(2):125-35
/ Chang-Mo Jeong et al.
10 The effect of various thread designs on the initial stability of taperimplants
J Adv. Prosthodont. 2009;1:19-25
/ Young-Jun Lim et al.
11 Influence of tungsten carbide/carbon coating of implant-abutmentscrew on screw loosening
J Kor Acad Prosthodont.
2008;46(2):137-47
/ Chang-Mo Jeong et al.
2013.02 ver.4.0 Disposable, re-use prohibited, medical applianceUser Manual
Osstem Implant product informationOsstem Implant dental fixtures and products are manufactured using medical gradeTitanium. Osstem Implant abutments, denture material and surgical tools are onlycompatible with Osstem fixtures. For more detailed information about each product,please refer to the user manuals, catalogs or please visit our corporate website(www.osstem.com). Please check all product labels for product codes,specifications, manufactured dates and expiration dates.
SterilityFixtures, cover screws and healing abutments are cleansed and gamma-sterilized.These products are disposable sterile medical appliances, and must be used in a sterilefield. If the package is damaged or has expired, it must not be used. If the productpackage has been opened but not used, there is a risk of contamination and it is notrecommended that the product resterilized and therefore should be discarded.
Storage conditionsStore all products in a dry place at room temperature (30oC). Avoid direct sunlight.
General precautionsDental implant surgery require proper and formal training and education.
Cautions before dental surgeryBefore dental implant surgery, a through patient health history review, oral andradiographic examinations must be completed to determine bone quality and propertreatment planning.
Cautions during dental implant surgeryOsstem Implant System are for single or two stage dental implant procedures. Inorder to minimize damage to the patient's tissue, special attention to temperature,surgical lesions and eliminating all sources of contamination and infection areneeded. Any deviation from the standard surgical protocol increases the risk offailure. When inserting the dental implant, sufficient cooling must be introduced(water or saline) and excessive torque (greater than 55Ncm) can result in dentalimplant fracture or possibly bone necrosis. Placing dental implants greater than 300has a very high risk of implant fracture. Direct pressure to the fixture should beavoided right after surgery. Immediate or delayed loading of the fixture must bedetermined after proper examination of the patient's bone condition and initialstability after placement.
"Mini" implants or implants with a diameter less than 4.0mm are not recommendedfor the posterior region.
Ultra-wide dental implants are recommended for the posterior region but should notbe used with angled abutments. If considering an Ultra-wide dental implant, properradiographic evaluation must be made to determine the bone mass and potentialanatomical restrictions. Short dental implants (diameter greater than 5mm andshorter than 7mm) are only used for the posterior region. The clinician must
thoroughly evaluate the patient's condition and recognized the following issues:1) bone loss due to peri-implantitis, 2) changes to the dental implant condition,3) proper osseointegration determined by a x-ray examination. If there is movementor if there is bone loss more than 50%, removing the dental implant should be acourse of action. Wide diameter implants should be performed as a two stagesurgery. Sufficient healing time must be given before splinting with other implants orwhen loading. Immediate loading is not recommended.
Take care when placing dental implants with HA coating. The coating is prone tocracking or fracturing under high torque, therefore hard bone should be avoided andbe inserted under 35Ncm of force.
CA and SOSI treated dental implants are encased in a solution to prevent the chemicallytreated surface from reacting with air. After removing the CA or SOSI dental implant,place the implant within 15 minutes to avoid degradation of the surface.
WarningImproper patient selection and treatment planning may result in dental implant failureor loss of bone. Osstem Implants must not be used for purpose other thanprescribed and must not be alter in any shape or form. Implant movement, boneloss, and chronic infections can result in implant failure.
IndicationsOsstem Implant Systems are designed to replace a patient's tooth or teeth. They canbe placed in both the maxillary and submaxillary alveolar bones and after fullosseointegration can be restored prosthetically. Osstem Implant Systems offer bothtemporary and final prosthesis and can be retained by cement, screw, overdentureor fixed bridge.
Side effectsThere are possible side effects after implant surgery (lost of implant stability, damageto dentures). These issues can be due to the lack of bone or poor bone quality, aninfection, patient's poor oral hygiene, non compliance with post op procedures,movement of the implant, degradation of surrounding tissue, or improper placementof the dental implant.
ContraindicationsPatients with the following contraindications are not eligible for dental implants: - Patients with blood clotting issues or issues with wound healing.- Diabetic patients- Patients that smoke or drink excessively- Patient's with compromised immune systems due disease or chemo and radiation
therapy.- Patients with an oral infection or inflammation (improper oral hygiene or teeth
grinding)- Patients with an incurable malocclusion/arthropathia and insufficient arch space.