Download - Natural touch nt600 (en)
NATURAL
TOUCH
2014 PROJECTINDUSTRIAL I
Introduction of Heat Insulation Coating
Eco Friendly Coating Materials : NT-600
Energy Saving
• Reduction of Radiation Heat
• Fuel Saving
Enviro Improvement
• Worker Protection• Eco Improvement
Economic Increase
• Quality Improvement• Short ROI
에너지(Energy)
환경(Environment)
경제(Economy)
Coating
Insulation
- 3 -
3
Heat Preserving & Insulation Coating NT-600
WORLD BEST ECO-FRIENDLY HEAT PRESERVING AND
INSULATION
NT-600 Multi-purpose Heat reservation & Insulation Coating
Fireproof, non-toxic, hydro-insulating coating material mixed with 8 different types of ceramics and special plastics, which is resistant to corrosion and mildew mold;
It can be coated on ducts or pipes of 540°C (the internal temperature) up to the thickness of 20 to 25mm so that it will lower the external temperature up to 75 to 110°C
Features
thermal resistant temperature: 1500°Creducing more than 35% of energyno rusting on pipes due to dew condensationno stopping factory lines to be treatedeasy to maintain and repair
Application
outer coating on fireproof bricksinsulating high temperature and low temperature pipes insulating pipe elbows and valves
color: dark grey (different colors available)thickness after the treatment: 10mm-25mm after being coated more than twice
coverage of temperature: wide range of temperature from -250°C to 1500°Cthermosetting time: 14 daysinterval between each coating: 2 hoursDilution : water
- 5 -
1. Concept of Heat Insulation Coating
Multipurpose : Heat Insulation, Workers Protection & Corrosion Proof
♦ Feature: workable on any materials(product) at below 400℃
♦ Working Temp: -25~600℃ ( Different effect of heat insulation on thickness)
♦ Materials : Air-encapsulated Ceramic and Special Acrylic Binder,
♦ Safety : Low-VOC, Non-toxic, Fire Proof, Very safe to use
Verification of Function by Various Method
♦ Strict KSF test of Weatherproof, Adhesive, Elasticity, Ultraviolet Safety, ETC
♦ Heat Insulation depends upon air pocket generated and durability
♦ Easy for maintenance and repair as a Heat Insulation Coating with unique
engineering data
♦ Most economic Heat Insulation, Fast solution & method for workers Protection
- 6 -
NT-600 uses Heat Transfer Principle like Conductivity, Convection, Radiation
and Reflection
♦ Fine Particle Structure of Pop-Corn like Spray Coating has the reflection
effect of over 85%
♦ Each Ceramic Particles keeping air help heat transfer very late
♦ Heat Transfer Coefficient of air is very low and drop significantly heat
transfer rate of surface
♦ The role to prevent corrosion and minimize heat transfer of coated
materials can be played simultaneously
Each Particles are composed of micro-particles of air encapsulated
Thermal barrier effect by specific reaction when heat transferring
Minimize Heat Floating through surface
Heat ReflectionHeat Reflection
2. Action Principle of Heat Insulation Materials
- 7 -
No Pollution as Pure Inorganic Materials
Endure Heat Transformation Difficult to Disjoin
Endure High Temperature
Block Off Air to protect corrosion of materials
Nonflammable & No Toxin Gas
Inflammable
Corrosion Resistance Elasticity
High-Temp Resistance
Eco-Friendly
NT-600
3. Features of Insulation Coating
- 8 -
4. Application of Coating Insulation
NT-600
Heating Equipment
Boiler
Valve, Flange
Dryer
IncineratorReactor
Useful for Difficult Heat Preservation Place
Excellent Effect of Heat Insulation in Thin-Walled Section
Prevent Burning of workers
No harmful to human as non-toxin Materials
Possible to Coat while facility is operating( under 400 C. Deg)
Protect Corrosion Under Insulation
Protect Dew Condensation
High Solid Content and Low-VOC Products
Easy to coat non-uniform surface
Nonflammable Materials
Adhesiveness, Elasticity, Excellent Retention of Heat insulation
5. Merits of Coating Insulation
Working Procedures of Insulation Coating
에너지(Energy)
환경(Environment)
경제(Economy)
Coating
Insulation
Property
Surface Temp : 60~400 ℃- 1st /2nd : 1~3mm Coating ☞ Protect Sagging- 3rd/4th : 4~7mm Coating ☞ after complete
drying of 1st / 2nd usually after 2 hours
- Talk with us when Temperature is over 400℃
Thickness: If heat is insulated, No Limitation No working when heavy snow or heavy Rain
Working Condition
Surface Treatment : Power Washing by Air Ferrous Surface : Pre-Cleaning before Heat
Insulation Coating. Should remove rust Non – Ferrous Surface : Possible direct coating
but should remove oil, stain, dust, etc.
Cautious Points before working
1. Property and Coating Procedures
온도(℃) 경화시간(Hr)
10~50 21
51~100 19
101~150 17
151~200 15
201~250 13
251~300 11
300이상 9
Hardening Time
Gross (Net )Weight : 16(15)kgs/22ℓ Flash Point : N.A. Storage
- Keeping at over 15℃- Avoid Direct Light- Storage Time Should be short
Expiration : 1 year after Production Caution : Should not be frozen
Packing, Handling, Storage
Safety Rule When Working
Should ware Safety Glasses, Mask.- No Touch if Possible- If touched, immediate wash by soap
Need Ventilation in the Sealed Room Cloth : Safety Cloths and Gloves
Mixing & Dilution Method
Mixing: Paddle or Electric Mixer Dilution: No Need But if required,
Max. 10% is OK Packing : 22ℓ Plastic Can,
If Sealing is well, reusable.
2. Hardening Time & Treatment, Storage Safety Rule
에너지절감
(Energy)
환경개선(Environment)경제성향
상(Economy)
Application of Heat Insulation Coating & Example
Heat
Insulation
Coating
Before Coating Temp : 185℃
Heat Insulation Coating After Coating works : 55℃
< L Co. >- Heat Insulation Coating for Energy
Efficiency improvement for Incinerator- Effect : △T = 130℃- Remarks : Coating directly on the Rusted
Surface without pre-cleaning
1. Heat Insulation Coating Example (1)
260℃ before insulation coating 110℃ after heat insulation coating
Advantages
Save Energy by maximizing Heat Reserve effectSecure Workers SafetySemi-permanently Usable Corrosion ProtectionNo Harmful to human Advantage to treat waste less expenses and faster
< L Co.>- Heat Insulation Coating for Energy
Efficiency Improvement - Effect : △T = 150℃- Remarks : Coating directly on the
Rusted Surface without pre-cleaning
1. Heat Insulation Coating Works Example (2)
170℃ before coating on Strainer
Heat Insulation Coating on Strainer 45℃ after coating on Strainer
< L Co >
- Heat Insulation Coating for Energy Efficiency Improvement
- Effect : △T = 125℃- Remarks : Coating directly on the
rusted surface without pre-cleaning
1. Heat Insulation Coating Works Example (3)
180℃ before coating on Trap
Heat Insulation Coating on Trap
55℃ after insulation coating on trap
< L Co >- Heat Insulation Coating for Energy
Efficiency Improvement
- Effect : △T = 125℃
- Remarks : Coating directly on therusted surface without pre-cleaning
1. Heat Insulation Coating Works Example (4)
180℃ before coating on Flange
50 ℃ after coating on FlangeCoating works on Flange
< L Co >
- Heat Insulation Coating for Energy
Efficiency Improvement
- Effect : △T = 130 ℃
- Remarks : Coating directly on therusted surface without pre-cleaning
1. Heat Insulation Coating Works Example (5)