Download - MULTI˜SERVICE AND UNIFIED SECURITY GATEWAYS
MULTI-SERVICE AND UNIFIED SECURITY GATEWAYSQuick Start Guide V1.0
USBSATA
0/MGMT1
23
45
67
PWRRESET
CONSOLE
SYS
8F9F
SPEED10/100
1000LINK/ACT
Security Gateway
DOWNLINK
SFP+SFP
USBSATA
0/MGMT1
23
45
67
PWRRESET
CONSOLE
SYS
8F9F
SPEED10/100
1000LINK/ACT
Security Gateway
DOWNLINK
SFP+SFP
SG-5105
PoE
Status
RESET
WAN0
LAN1/WAN1
LAN2
LAN3LAN5
LAN7
LAN4LAN6
SG-3110
CONSOLE
Accessories
Introduction
Thank you for choosing FS Gateways. This guide is designed to familiarize you with the layout of the
gateway and describes how to deploy the gateway in your network.
Rubber Pad x4Power Cord x1
SG-5110
SG-5105
SG-3110
SG-3110
SATA0/MGMT 1 2 3 4 5 6 7
PWR RESET
CONSOLEUSB
SYS
8F 9F
SPEED10/100
1000
LINK/ACT
Security Gateway
DOWNLINK
SFP+ SFP
SATA0/MGMT 1 2 3 4 5 6 7
PWR RESET
CONSOLEUSB
SYS
8F 9F
SPEED10/100
1000
LINK/ACT
Security Gateway
DOWNLINK
SFP+ SFP
PoEStatus RESET
WAN0
LAN1/WAN1
LAN2
LAN3 LAN5 LAN7
LAN4 LAN6
SG-3110CONSOLE
SG-5105
Grounding Cable x1
M4 Screw x6Mounting Bracket x2
Front Panel Ports
M4 Screw x6Rubber Pad x4
Power Cord x1
Hardware Overview
Mounting Bracket x2
Console Cable x1
Power Cord Tie x1
Network Cable x1
SG-5105/SG-5110
SG-3110
CONSOLE
NOTE: FS gateways have dust plugs delivered with them. Keep the dust plugs properly and use them to protect idle optical ports.
PoEStatus RESET
WAN0
LAN1/WAN1
LAN2
LAN3 LAN5 LAN7
LAN4 LAN6
SG-3110CONSOLE
USB RJ45
Front Panel Buttons
RJ45 10/100/1000BASE-T ports for Ethernet connection
SFP port for 1G connectionSFP
SFP+
CONSOLE
MGMT
USB
An RJ45 console port for serial management
An Ethernet management port
A USB management port for software and con�guration backup and o�ine software upgrade
SFP+ port for 10G connection
Ports Description
SG-5105/SG-5110
SG-5105/SG-5110
SG-3110
SATA0/MGMT 1 2 3 4 5 6 7
PWR RESET
CONSOLEUSB
SYS
8F 9F
SPEED10/100
1000
LINK/ACT
Security Gateway
DOWNLINK
SFP+ SFP
SATA0/MGMT 1 2 3 4 5 6 7
PWR RESET
CONSOLEUSB
SYS
8F 9F
SPEED10/100
1000
LINK/ACT
Security Gateway
DOWNLINK
SFP+ SFP
RJ45CONSOLE
MGMT
USB SFP+ SFP
RESET
RESET
RESET
Press and release the RESET button to restart the device. To restore to factory default, press and hold the RESET button for more than three seconds.
Button Description
PoEStatus RESET
WAN0
LAN1/WAN1
LAN2
LAN3 LAN5 LAN7
LAN4 LAN6
SG-3110CONSOLE
Back Panels
Back Panel Button
Power ON/OFF Control the gateway power supply.
Button Description
Front Panel LEDs
SG-5105/SG-5110
SG-3110
SG-3110
Status
RJ45
PoE
Solid Green
Blinking Green
Blinking Green
Solid Green
Solid Green
Red/Green Flashing Alternately
LEDs Status
System is being initialized.
The initialization process is complete.
Solid Red
Solid Red
The system sends out an alarm.
The port is receiving or transmitting data.
The port is up.
PoE works normally.
An alarm is generated.
PoE overload occurs.
Description
SATAON
100-240V~;50/60Hz,0.6A OFF
100V-240V~;50/60Hz;3A max
Grounding Point Power Supply
Power SupplyON/OFF
Hard Disk Drive Slot
Grounding Point
PoEStatus RESET
WAN0
LAN1/WAN1
LAN2
LAN3 LAN5 LAN7
LAN4 LAN6
SG-3110CONSOLE
Status RJ45 PoE
PWR
SYS
SATA
LINK/ACT
SPEED
SFP+
SFP
O�
Solid Green
Blinking Green
Solid Green
Solid Green
Blinking Green
Solid Green
Blinking Green
O�
Solid Orange
Solid Green
Solid Green
Blinking Green
Blinking Green
LEDs Status
The power module is not in the position or fails.
The power module is working properly.
The system is being initialized.
The initialization process is complete.
Solid Red The system sends out an alarm.
The SATA disk is installed.
The port is receiving or transmitting data.
The port is connected at 10/100/1000M.
The �ber port is connected.
The �ber port is receiving or transmitting data.
The �ber port is connected.
The �ber port is receiving or transmitting data.
The port is connected at 1000M.
The port is connected at 10/100M.
The SATA disk is reading or writing data.
Description
SG-5105/SG-5110
SATA0/MGMT 1 2 3 4 5 6 7
PWR RESET
CONSOLEUSB
SYS
8F 9F
SPEED10/100
1000
LINK/ACT
Security Gateway
DOWNLINK
SFP+ SFP
SYS
SATAPWR SFP+ SFP
LINK/ACT
SPEED
Installation Requirements
Before you begin the installation, make sure that you have the followings:
Phillips screwdriver.
Standard-sized, 19" wide rack with a minimum of 1U height available.
Category 5e or higher RJ-45 Ethernet cables and �ber optical cables for connecting network devices.
Do not place the device in a damp or wet location. Do not let any liquid enter the chassis.
Do not install the equipment in a dusty environment.
Keep the device away from heat sources.
Ensure the normal grounding of device.
Wear an anti-static wrist strap to install and maintain the device.
Use UPS (Uninterruptible Power Supply) to prevent power failure and other interferences.
Mounting the Gateway
Desk Mounting
1. Attach four rubber pads to the bottom.
2. Place the chassis on a desk.
USB
SATA
0/MGMT1
23
45
67
PWRRESET
CONSOLE
SYS
8F9F
SPEED10/100
1000LINK/ACT
Security Gateway
DOWNLINK
SFP+SFP
Site Environment:
SATA
0/MGMT1
2
3
4
5
PWRRESET
CONSOLE USB
SYS
SATA
0/MGMT1
23
45
6
PWRRESET
CONSOLE USB
SYS
7
8F
9F
SPEED10/1001000
LINK/ACT
Security Gateway
DOWNLINK
SFP+SFP
Rack Mounting
1. Secure the mounting brackets to the two sides of the gateway with six M4 screws.
2. Attach the gateway to the rack using four M6 screws and cage nuts.
8F9F
SPEED10/100
1000LINK/ACT
Security Gateway
DOWNLINK
SFP+SFP
Grounding the Gateway
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
gateway is mounted.
2. Secure the grounding lug to the grounding point on the gateway back panel with the washers and
screws.
Connecting the Power
1. Plug the AC power cord into the power port on the back of the gateway.
2. Connect the other end of the power cord to an AC power source.
CAUTION: Do not install the power cord while the power is on, and when the power cord is connected, the fan will start to operate whether the power button is on or o�.
OFF
ON SATA
100-240V~; 50/60HZ,0.6A
OFF
ONPSO
~100-240V/1A
Connecting the RJ45 Ports
1. Connect an Ethernet cable to the RJ45 port of a computer or other network devices.
2. Connect the other end of the Ethernet cable to the RJ45 port of the gateway.
SATA
0/MGMT1
23
45
67
PWRRESET
CONSOLE USB
SYS
8F9F
SPEED10/100
1000
SFP+SFP
Connecting the SFP/SFP+ Ports
1. Plug the compatible SFP/SFP+ transceiver into the �ber port.
2. Connect a �ber optic cable to the �ber transceiver. Then connect the other end of the cable to
another �ber device.
0/MGMTRESET
CONSOLE USBPWR
SYS
SPEED10/1001000
Security Gateway
LINK/ACTDOWNLINK
9F
8F
7
6
5
4
3
2
1
SFP
SFP+
WARNING: Laser beams will cause eye damage. Do not look into bores of optical modules or optical �bers without eye protection.
Connecting the Console Port
1. Insert the RJ45 connector into the RJ45 console port on the front of the gateway.
2. Connect the DB9 female connector of the console cable to RS-232 serial port on the computer.
SATA
0/MGMT1
23
45
67
PWRRESET
CONSOLE USB
SYS
8F9F
SPEED10/100
1000
SFP+SFP
0/MGMTRESET
CONSOLE USB
87
64
32
1
SATA
PWR
SYS
1. Connect one end of a standard RJ45 Ethernet cable to a computer.
2. Connect the other end of the cable to the MGMT port on the front of the gateway.
Connecting the MGMT Port
Security Gateway
SPEED10/100
1000
Wireless Controller
LINK/ACTDOWNLINK
8F7F
SFPSFP
Con�guring the Gateway
Con�guring the Gateway Using the Web-based Interface
Step 1: Connect the computer to the Management port of the gateway using the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x. (“x” is any number from 2 to 254.)
? x
OK Cancel
General
I P a d d r e s s :
S u b n e t m a s k :
D e f a u l t g a t e w a y :
Yo u c a n g e t I P s e t t i n g s a s s i g n e d a u t o m a t i c a l l y i f y o u r n e t w o r k s u p p o r t s t h i s c a p a b i l i t y . O t h e r w i s e , y o u n e e d t o a s k y o u r n e t w o r ka d m i n i s t r a t o r f o r t h e a p p r o p r i a t e I P s e t t i n g s .
I nternet Protocol Vers ion 4 ( TCP/ IPv4) Proper t ies
Use the fol lowing IP address :
Obtain an IP address automatical ly
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit A d v a n c e d . . .
. . . 21168192
0255255255
. . .
. . .
. . .
. . .
Obtain DNS ser ver address automatical ly
Use the fol lowing DNS ser ver addresses :
Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password,
admin/admin.
Step 4: Click Log In to display the web-based con�guration page. You are then required to enter and
con�gure a new password for the account the �rst time you log in.
Internet Explorer 10/11, Google Chrome, FirefoxRecommended
Log In
admin
*****
Troubleshooting
According to the power indicator on the front panel, the gateway can be used to determine whether
the power supply system of the gateway is faulty. If the power supply system is working normally, the
power indicator should remain lit. If the power indicator light is unlit, please check the following:
1. Whether the power switch is turned on.
2. Whether the gateway power cable is connected correctly.
3. Whether the cabinet power sockets are loosely connected to power modules.
Con�guring the Gateway Using the Console Port
Power System Fault
Step 1: Connect a computer to the gateway's console port using the console cable.
Step 2: Start the terminal simulation software such as HyperTerminal on the computer.
Step 3: Set the parameters of the HyperTerminal: 9600 bits per second, 8 data bits, no parity, 1 stop
bit and no �ow control.
Step 4: After setting the parameters, click Connect to enter.
WARNING: Do not plug or pull the power cable when the power switch is already turned on.
xQuick Connect
Protocol:
The port may be manually entered or selected from the list.
Serial
Flow Control
DTR/DSR
RTS/CTS
XON/XOFF
Save sessionShow quick connect on startup
Open in a tab
Connect Cancel
COM3
9600
8
None
1
Port:
Baud rate:
Data bits:
Parity:
Stop bits:
Name of pipe:
NOTE: If you perform remote access via SSH and Telnet, the admin password should have already been changed since the simple password is potential security hazards.
Copyright © 2020 FS.COM All Rights Reserved.
Q.C. PASSED
Support and Other Resources
Download
Help Center
Contact Us
https://www.fs.com/download.html
https://www.fs.com/service/help_center.html
https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that any damage or faulty items due to our workmanship, we will o�er a
free return within 30 Days from the day you receive your goods. This excludes any custom made
items or tailored solutions.
Warranty: FS gateways enjoy 3 years limited warranty against defect in materials or
workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
3
The console con�guration terminal shows system booting message when the device is powered on.
If the con�guration system has failed, it displays error information or nothing at all. If the
con�guration terminal shows no information, please check the following:
1. Make sure the power supply is correctly connected and powered on.
2. Verify the Console cable is connected properly.
3. Ensure the terminal con�guration settings are correct.
Con�guration System Troubleshooting
If the con�guration terminal shows error codes, it is likely that the terminal (such as HyperTerminal)
parameters are set incorrectly. Please con�rm the parameters of the terminal (such as HyperTerminal).
Troubleshooting for Terminal Show Error Codes