Download - MID Flow Sensor Brochure UK
-
7/30/2019 MID Flow Sensor Brochure UK
1/6
www.ifm.c
om/mid
Flows
ensors
Compact and low-costmonitoring ofconductive liquids.
Magnetic-inductiveflow metering
from ifm.
-
7/30/2019 MID Flow Sensor Brochure UK
2/6
Volumetric flow sensor efector mid. High-precisionmeasurement, display and signalling of liquid media.
For industrialapplications
Coolant monitoring Cooling water monitoring
Ideal in widely
branched cooling
systems, e.g. weld-
ing lines. The
volumetric flow
sensorefector mid
detects very small
deviations from
the specified volu-
metric flow quan-
tity, for example
for leaks, and
monitors at the
same time the
temperature of
the cooling water.
This guarantees
process safety and
quality.
Decentraliseddetection andmonitoring ofliquid media.
The diagnostic
functionality of
efector mid, e.g.
analogue outputs,
binary limit values,
consumed quanti-
ties during the
specified period or
temperature mon-
itoring in the
medium, enables
the reliable opera-
tion of cooling cir-
cuits and systems.
Due to the contin -
uous monitoring
the sensor can be
perfectly integrat-
ed into the condi-
Condition-basedmaintenance.
Monitoring ofconductive liquids.
tion-based main-
tenance concepts.
This enhances the
reliability of the
plant; uptime is
increased. Expen-
sive consequential
damage resulting
from lack of cool-
ant is prevented.
By integration into
a real-time-main-
tenance concept
maintenance can
be implemented
at the right time,
in the right place,
using the right
material and oper-
ators.
The magnetic-
inductive volumet-
ric flow sensor is
suitable for moni-
toring conductive
media. The media
have a different
electrical conduc-
tivity. efector mid
measures liquid
media from a
conductivity of
> 20 S/cm.
electrical conductivity
sea water (salt)
water glycol mixtures
water-based coolants
drinking water
industrial water
-
7/30/2019 MID Flow Sensor Brochure UK
3/6
Measuring length
and electronics are
integrated into a
robust and com-
pact housing. So
otherwise usual
inlet and outlet
pipe lengths can
be reduced to a
minimum. Pressure
loss is negligible.
Compact, informativeand easy to install.
Four-digit alpha-
numeric display
for information on
site: current volu-
metric flow, accu-
mulated total
quantity and
medium tempera-
ture. l/min or m3/h
can be selected as
the unit of mea-
surement. Two
LEDs indicate the
switch points.
Mounting via
R 1/2 or R 3/4
adapter ensures
easy installation in
the pipe.
Cooling process optimisation Water supply documentation
efector mid the
reliable and low-
cost solution for
monitoring the
exact supply and
consumption of
liquids in industri-
al processes. Dueto the measuring
range of 0 to
25 l/min and an
accuracy of 2 %
of the measured
value the unit can
be used in a wide
range of applica-
tions. Volumetric
flow in the oppo-
site direction is
also indicated.
alphanumeric
display
switch point indication
programming
buttons
Photoreference
Inductionhardening:R.
RiekerGmbH,
Leingarten
Waferproduction
:centrothermthermalsolutionsGmbH+CoKG,B
laubeuren
-
7/30/2019 MID Flow Sensor Brochure UK
4/6
Operating voltage [V] 19...30 DC*
Current rating [mA] 2 x 200
Short-circuit protection, pulsed 2 x 200
Analogue output 4...20 mA / 0...10 V (4...20 mA: max: 500 / 0...10 V: min. 2000 )
Flow monitoringMeasuring range [l/min / m3/h]
0...25 / 0...1.5
Measurement error [%]
Setting range [l /min / m3/h]Set point, SPAnalogue start point, ASPAnalogue end point, AEP
Start-up delay [s]
(2 % measured value + 0.5 % VMR)
0.25...25 / 0.015...1.50...20 / 0...1.2
5...25 / 0.3...1.5
0...50
Temperature monitoringMeasuring range [C]
-20...80
Measurement error [C] 2.5 (Q > 1 l/min)
Pressure resistance [bar] 16
Medium temperature [C] -10...70
Reverse polarity, overload prot. 2 x 200
Technical data volumetric flow sensor efector mid
Application areaconductive liquids
(conductivity: 20 S/cm / viscosity: < 70 mm2/s at 40 C)
Electrical design
Connection
DC PNP/NPN
4-wire
DC PNP
4-wire
Output 1
Output 2
normally open / normally closed programmableor pulse
normally open / normally closed programmableor analogue (4...20 mA / 0...10 V, scalable)
analogue(4...20 mA)
Process connection G 1/2 male thread
Order no. SM6000 SM6050
Sockets
Description Order no.
2 m PUR, M12 angled, without LED EVC004
5 m PUR, M12 angled, without LED EVC005
Accessories (selection)
Description Order no.
Adapter G 1/2 - R 3/4
Process connection G 3/4 flat sealAdapter G 1/2 - R 1/2
110
73
M12x1
16
G G
21
21
M12x1
54
*to EN50178, SELV, PELV
Setting range [C]
Set point, SPAnalogue start point, ASPAnalogue end point, AEP
-19.8...80.0-20...600...80
Display unitOutput statusMeasured valuesProgramming
6 LEDs green (l/min, m3/h, m3, 103, C)2 LEDs yellow
4-digit alphanumeric display4-digit alphanumeric display
Protection IP 67, III
Housing materials stainless steel (316S12); stainless steel (316S16); PBT-GF 20; EPDM/X (Santoprene)
Sensor materials stainless steel (316S12); PEEK (polyetheretherketone); FKM
Connection M12 connector; gold-plated contacts
E40189E40199
Grounding clamp E40196
SM6000
-
7/30/2019 MID Flow Sensor Brochure UK
5/6
Ensuring product qualityand plant up-time.
Volumetric flow sensorefector mid:
Simultaneous monitoring
of volumetric flow quantityand temperature of con-ductive liquids.
Functionality and precisionat the right price.
Local indication of thecurrent volumetric flowquantity, total quantity andtemperature.
For external evaluation:
Switching, pulse and ana-logue outputs for signaland control tasks.
Less cost:Setting and monitoring ofcooling circuits for optimumperformance.
More safety:Immediate detection ofeven very small leaks.
High transparency:
Counting and allocation ofconsumed quantities.
Exactly right:Exact determination ofliquid quantities.
Magnetic-inductiveflow metering.
converted in the
evaluation electro-
nics. As the pipe
cross-section is
defined, the
volumetric flow
quantity can be
determined
exactly.
No moving com-
ponents are used,
therefore the
system works relia-bly, wear and
maintenance free.
The volumetric
flow sensor isbased on Faradays
principle of induc-
tion. The conduc-
tive medium
flowing through a
pipe in a magnetic
field generates a
voltage which is
proportional to
the flow velocity
or volumetric flow
quantity. This vol-
tage is tapped via
electrodes and
M = magnet
E = electrodes
V = flow velocity
V
M
M
E
-
7/30/2019 MID Flow Sensor Brochure UK
6/6
ifmarticleno.
7511274Wereservetherighttomaketechnicalalterationswithoutpriornotice.PrintedinGermanyo
nnon-chlorinebleachedpaper.02/08
Over 70 locations worldwide at a glance atwww.ifm.com
visit our website:
www.ifm.com
Position sensorsand object recognition
Inductive sensors
Capacitive sensors
Magnetic sensors,cylinder sensors
Safety technology
Valve sensorsPhotoelectric sensors
Object recognition
Encoders
Evaluation systems,power supplies
Connection technology
Fluid sensorsand diagnostic systems
Level sensors
Flow sensors
Pressure sensors
Temperature sensors
Diagnostic systems
Evaluation systems,power supplies
Connection technology
Bus systems
Bus system AS-Interface
Power supplies
Connection technology
Identification systems
DataMatrix code-reading
systemsRF-identification systems
Power supplies
Connection technology
Control systems
Control systemsfor mobile vehicles
Connection technology
Overview ifm main catalogues:
ifm electronic gmbh
Teichstrae 445127 EssenTel. +49 / 0201 / 2 42 20
Fax +49 / 0201 / 2 42 22 00E-Mail: [email protected]