Download - KOTA SUPER THERMAL POWER STATION PPT
![Page 1: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/1.jpg)
A
Presentation
On
Summer Training
At
KOTA SUPER THERMAL POWER STATION
KOTA
Submitted to:-
Prof. Dr. Dinesh Birla (H.O.D. Electrical Dept.)
Dr. M.K. LALWANI (Asso. Prof.)
Submitted by:-
MUKESH TANEJA
11/046
B.TECH FINAL YEAR
(Electrical Engineering)
UNIVERSITY COLLEGE OF ENGINEERING,
RAJASTHAN TECHNICAL UNIVERSITY, KOTA
![Page 2: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/2.jpg)
INTRODUCTION OF KSTPS
▪ LOCATION:-
It is located on the left bank of the CHAMBAL river
▪ BASED ON RANKINE CYCLE:-
A thermal power plant is a power plant in which the prime mover is steam. Water is heated, turns into steam and spins a turbine which drives an electrical generator. After it passes through the turbine, the steam is condensed in a condenser and recycled to where it was heated; this is known as a Rankine cycle.
▪ TOTAL GENERATING CAPACITY:- 1240 MW
![Page 3: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/3.jpg)
FAVARABLE CONDITION OF KSTPS
AVAILABILITY OF WATER
SUPPLY OF FUEL
NEARNESS TO LOAD CENTRE
TRANSPORTATION FACILITY
DISTANCE FROM POPULATED AREA
![Page 4: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/4.jpg)
STAGES
Unit 6 – 195 MW
Unit 1 – 110 MW
Unit 2 – 110 MW
Unit 3 – 210 MW
Unit 4 – 210 MWUnit 5 – 210 MW
Unit 7 – 195 MW
Stage I
Stage II Stage III Stage IV
Stage V
DESIGN
110 + 110 + 210 + 210 + 210 + 195 +195 = 1240 MW
![Page 5: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/5.jpg)
LAYOUT OF POWER PLANT
POWER PLANT MAINLY CONSISTS FOUR CIRCUIT :-
1. COAL AND ASH CIRCUIT
2. AIR AND FLUE GAS CIRCUIT
3. FEED WATER AND STEAM CIRCUIT
4. COOLING WATER CIRCUIT
![Page 6: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/6.jpg)
The pulverized coal
is fed to the boiler
by conveyor belts
From the coal storageplant, coal is delivered
to the coalhandling
plant where it ispulverized
![Page 7: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/7.jpg)
Coal Storage
Coal Handling Plant
Ash Storage
Ash Handling Plant
Super Heater
Economizer
Air Pre-heater
Generat
orExciterTurbine
Chimney
Feed Water Heater
Deaerator
Make up Water
Air
Ash
STEAM
WATER
FLUE GASES
Coal
Forced draught fan
Inuceddraught fan
Condenser
BOILER
Cool water
Hot water
GENERAL LAYOUT
![Page 8: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/8.jpg)
BOILER
▪ Boiler is a place where water is being converted into steam with burning of coal.
▪ It is closed vessel in which water under high pressure converted into steam.
▪ Type : Water Tube Boiler
▪ Capacity : 375 tons per hour
▪ Steam temperature : 540 °C
▪ Steam pressure :139gm/Cm2
▪ Efficiency : 86.6%
![Page 9: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/9.jpg)
BOILER
![Page 10: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/10.jpg)
WATER TREATMENT PLANT
▪ Pressure filter removes impurities from raw water.
▪ Carbon filter removes excess chlorine from clarified water.
▪ Demineralizing treatment plant removes dissolved impurities from clarified water.
▪ Conductivity, pH & silica content of this water must be checked time to time.
![Page 11: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/11.jpg)
ECONOMISER
▪ Flue gases coming out of the boiler carries lot of heat.
▪ Economiser uses this heat and heats feed water before entering into the boiler.
▪ It improves the efficiency of plant 10-12%.
▪ Temperature : 315 °C
![Page 12: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/12.jpg)
AIR PRE-HEATER
▪ Air Pre-Heater is used to preheat the air before entering into furnace.
▪ It recovers the heat of flue gases coming from Economiser.
![Page 13: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/13.jpg)
SUPER HEATER
▪ Super Heater is used to remove the moisture content from the steam.
▪ It raises the temperature of steam.
▪ Advantage:
▪ Increase efficiency
▪ Reduces corrosion of turbine blades.
![Page 14: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/14.jpg)
CONDENSER
▪ It reduce the turbine exhaust pressure so as to increase the specific output of the turbine.
▪ It recover high quality feed water in the firm of condensate and feed it back to the steam generator without any further treatment.
![Page 15: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/15.jpg)
DE-ARATOR
▪ The condensed water is passed by a feed pump through a Dearater.
▪ It is used to remove extra air and non-condensable gases are removed from the hot water to avoid pitting / oxidation.
![Page 16: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/16.jpg)
STEAM TURBINE▪ Steam turbine is a rotating machine which converts kinetic energy of
the STEAM into mechanical energy.
▪ Type : Impulse Turbine
▪ Types of TURBINE according to steam flow
▪ High Pressure TURBINE : 25 blades and single flow
▪ Inter Mediate Pressure TURBINE : 17 blades and single flow
▪ Low Pressure TURBINE : 8 blades and double flow
SPECIFICATIONS
![Page 17: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/17.jpg)
GENERATOR
• It converts mechanical energy into electrical energy.
• The generator is driven by directly coupled steam turbine at a speed of 3000 rpm.
• Phase connection : Double Star
• Active Power : 7,10,000 KW
• Rated Voltage : 1,000 +5 %
• Frequency : 50 Hz
• Cooling : Hydrogen cooling
![Page 18: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/18.jpg)
![Page 19: KOTA SUPER THERMAL POWER STATION PPT](https://reader034.vdocuments.site/reader034/viewer/2022042503/55a205071a28abda648b45fe/html5/thumbnails/19.jpg)
Thank You