MDVRIPS700A Medical Digital Video Recorder
Installer User’s GuideBefore connecting, operating or adjusting this product, please read this instruction booklet carefully and completely.
FSN1949 - 01/20162 - English
Table of Contents
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Symbol Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Caution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 MDVR (IPS700A) Sample System Configuration . . . . . . . . . . 10Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Connect Input Sources . . . . . . . . . . . . . . . . . . . . . . . . . 12Connect Output to Video Display . . . . . . . . . . . . . . . . . . . 12Connect Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Connect Audio and Mechanical Switch . . . . . . . . . . . . . . . 13Connect a Remote Control Device . . . . . . . . . . . . . . . . . . 14Methods of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . 15Front Panel Control Keypad (OSD) . . . . . . . . . . . . . . . . . . 16General Specification . . . . . . . . . . . . . . . . . . . . . . . . . . 18Mechanical Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Cleaning Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . 23Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
The specifications and information in this document are subject to change without notice.
FSN1949 - 01/2016 English - 3
Overview
MDVR, part number IPS700A, is a medical digital video recorder from FSN Medical Technologies. It is intended to record and store video and still images from operating devices for later playback or transfer to other media.
MDVR is an advanced high quality video processing system that has built-in capabilities for signal source selection and multiple resolutions. MDVR is controlled through an Android app. (for RS232C or TCP/IP control, please consult the manufacturer).
Recording medical digital video is easy with MDVR. An accompanying control tablet runs the in-tuitive user interface and gives quick access to options for setup, recording, capture, file storage, patient information, play back, and data backup functions.
In addition, capture and recording can be controlled through an endoscopic camera head but-tons or a foot pedal accessory.
All recorded files are stored on MDVR’s internal hard disk drive. These stored files can then be played back on a display monitor, or restored to variety of media including external drives, memory sticks, DVDs, Blu‐ray disks, and network servers.
All MDVR inputs correspond with universal standards that accept VGA, DVI‐D (up to 1920x1080 resolution), composite video, and S‐video inputs.
FSN1949 - 01/2016
4 - English
Symbol Definitions
The following symbols appear on the product, its labeling, or the product packing. Each symbol carries a special definition, as defined below:
AC Voltage Switches on power
Switches off power Contained spare fuse
Dangerous : High Voltage Consult accompanying docu-ments
Indicates protective earth ground Power adapter
Indicates top-bottom direction Serial Number
Do not get wet Manufacturer
Maximum Stacking Fragile
Humidity limitation Indicates the manufacturing date
Temperature limitation Atmospheric pressure limitation
Authorized representative in the European community
Representative in the USA Tested to comply with FCC Class B standard.
Medical Equipment is in accordance with UL 60601-1 and CAN/CSA C22.2 No. 601.1 in regards to electric shock, fire hazards, and mechanical hazard.
Indicates proof of conformity to applicable European Economic Community Council directives and to harmonized standards published in the official jour-nal of the European Communities.
This symbol indicates that the waste of electronic equipment must not be disposed as unsorted municipal waste and must be collected separately. Please contact the manufacturer or other authorized disposal company to decommission your equipment.
Refer to the instruction manual / booklet. Equipotentiality.
Indicates the display is approved according to the CCC regulations.
China RoHS labels.
FSN1949 - 01/2016 English - 5
Safety and Instructions
Please read the following safety instructions as they are designed to prevent damage to property and harm to the user.
Warning / Caution
Failure to follow directions noted by this symbol could result in bodily harm or dam-age to equipment.
Notational Conventions
Prohibited Important to read and understand at all times
Do not disassemble Disconnect the plus from outlet
Do not touch Grounding to prevent an electrical shock
Power
Use only a proper plug and voltage.Improper power may cause electric shock or equipment damage.To avoid the risk of electric shock, this equipment must only be connected to a
power supply with protective grounding.
Installation
Do not connect any other wires or accessories to this system which do not comply.An improper wire may cause electric shock or equipment damage.Insert wires firmly so that they do not come loose.A bad connection may cause fault.
Operating environment
Be sure to contact this product’s supplier when installing your system in a location with heavy dust, high or low temperatures, high humidity, or chemical sub-stances.
Failure to do so may cause serious damage to your system.
Others
If this system does not operate normally, in particular, if there are any unusual sounds or smells coming from it, unplug it immediately.
Please contact supplier when you want to use this system with unknown equip-ment. Please power off and pull out the power cord when you want to move this system.
FSN1949 - 01/20166 - English
Caution
CAUTIONRISK OF ELECTRICAL SHOCK
DO NOT OPEN
This symbol alerts the user that important literature concerning the operation of this unit has been included. Therefore, it should be read carefully in order to avoid potential problems.
This symbol warns the user that un-insulated voltage within the unit may have sufficient magnitude to cause electrical shock. Therefore, it is dangerous to make contact with any part inside the unit.
To reduce the risk of electric shock, DO NOT remove cover (or back). There are no user service-able parts inside. Refer servicing to qualified service personnel.
To prevent fire or shock hazards, do not expose this unit to rain or moisture. Also, do not use this unit’s polarized plug with an extension cord receptacle or other outlets unless the prongs can be fully inserted.
The equipment is designed to meet the medical safety requirements for a patient vicinity device. This device may not be used in connection with life support equipment.
Underwriters Laboratories (UL) Classification: UL safety Compliance:
This system is U.L. Classified WITH RESPECT TO ELECTRIC SHOCK, FIRE AND MECHANICAL HAZ-ARDS ONLY IN ACCORDANCE WITH UL 60601-1/CAN/CSA C22.2 NO. 601.1
EEC Safety Compliance:
This system meets the requirements of EN-60601-1 so as to conform to the Medical Device Direc-tive 93/42/EEC (general safety information). Use 120V rating 5-15P type plug only in the U.S. This system is intended for connection to a separate medical grade power supply.
Caution: Make sure the power cord is the correct type that is required in your area.
This system has a universal power supply that allows operation in either 100-120V AC or 200-240V AC voltage areas (no user adjustment is required).
Use the proper power cord with correct attachment plug type. If the power source is 120 V AC, use a power cord which is a Hospital Grade Power Cord with NEMA 5-15 style plug, labeled for 125 volts AC with UL and C-UL approvals.
FSN1949 - 01/2016 English - 7
If the power source is a 240 V AC supply, use the tandem (T blade) type attachment plug with ground conductor power cord that meets the respective European country’s safety regulations.
The hospital-grade plug for medical products intended for use in Denmark has DEMKO approval and is rated 13 amps at 250Vac. Plug is recommended for use in medical applications and speci-fications are being added to the standard SB 107-2-D1. Plug mates with maker’s Danish hospital-grade socket. Hospital sockets have slightly different shaped openings allowing only the hospital plug, not the standard Danish plug, to be inserted, to protect the ac circuit in specific medical settings.
FCC WARNING :This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protec-tion against interference. This system can radiate radio frequency energy and, if not installed and used in accordance with the instructions, it may interfere with other radio communications equipment.
There is no guarantee that interference will not occur in a particular installation. If this equipment is found to cause harmful interference to radio or television reception, the user is encouraged to try to correct the interference by carrying out one or more of the following measures:
1. Reorient or relocate the receiving antenna. 2. Increase the distance between this system and the subject of interference.3. Plug this system into an outlet on a different electrical circuit than that to which the subject of
interference is connected.4. Consult the dealer or an experienced radio/TV technician for help.
NOTICES TO USER : This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1 )this device may not cause harmful interference, and (2) this device must accept any interfer-ence received, including interference that may cause undesired operation.
This equipment generates or uses radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual.
The user could lose authority to operate this equipment if an unauthorized change or modifica-tion is made.
FSN1949 - 01/20168 - English
Recycling : Follow local governing ordinances and recycling plans regarding the recycling or disposal of this equipment.
Servicing Do not attempt to service the system yourself as opening or removing covers may expose you to dangerous voltages or other hazards, and will void the warranty. Refer all servicing to quali-fied service personnel. Unplug the system from its power source and refer servicing to qualified personnel under the following conditions:
-If the power cord or plug is damaged or frayed. -If liquid has been spilled into the system. -If objects have fallen into the system. -If the system has been exposed to rain or moisture. -If the system has been subjected to excessive shock by being dropped. -If the enclosure has been damaged. -If the system seems to be overheated. -If the system emits smoke or abnormal odor. -If the system fails to operate in accordance with the operating instructions.
Accessories Use only accessories specified by the manufacturer, or sold with the system.
Classification Protection against electric shock : Class I including AC/DC power.
Applied Parts : No Applied Parts
Degree of safety in the presence of flammable anesthetics mixture with air or with oxygen or with nitrous oxide. Not suitable for use in the presence of a flammable anesthetics mixture with oxygen or with nitrous oxide.
Mode of operation : Continuous.
FSN1949 - 01/2016
1
2
3
4
5
6
7
English - 9
Item Description Pack Qty 1 MDVR (IPS700A) unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 User Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 3 AC power Cord (6ft, Medical Grade) . . . . . . . . . . . . . . . . . . . . . . . . 1 4 D-SUB cable (6ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 5 DVI cable (6ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 6 BNC cable for Video (6ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 7 SVHS cable for Video (6ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Package Contents
Verify that you received all components of your respective package.
Inspect each component and verify that none of the components have been tampered with in any way.
FSN1949 - 01/201610 - English
MDVR (IPS700A) Sample System Configuration
Display Monitor
Playback
Saved to Media:
Medical Digital
Video Recorder
Control
Interface
Start and stop with foot pedal or hand switch.
Source Signals
FSN1949 - 01/2016
1
2
3
4 5 6
78
9
10
11 12
13
14 15
16
17
18
19
20
21
22 23 24
English - 11
Connectors
1 Blu-ray Disk 13 Network port
2 USB 14 USB
3 LCD 15 RS232C
4 Capture button 16 DVI-D out
5 Record button 17 VGA out
6 Stop button 18 DVI-D in
7 Direction button 19 VGA in
8 Enter button 20 CVBS in
9 Menu button 21 CVBS out
10 Earth Terminal 22 S-Video in
11 AC ON/OFF SWITCH 23 Audio in/out
12 AC in 24 Foot pedal recording/capture
FSN1949 - 01/201612 - English
Connect Input Signals
Connect Output to Video Display
MDVR has connections to receive signals as DVI-D, VGA, CVBS, and S-Video. Specific applications will determine the type of input signal sources that will be connected to MDVR. Never use this system with damaged cords. Keep all cords away from areas where they may cause tripping.
MDVR can play back recorded images and video to a connected display monitor. Output connec-tion choices are DVI-D, VGA, and CVBS.
MDVR back panel
MDVR back panel
Connect input video signals here.
Connect a video display here.
FSN1949 - 01/2016 English - 13
MDVR back panel
Connect Power
Connect Audio and Mechanical Switch
Only use the specified plug and voltage. Power requirements are: AC 100~240V / 50~60Hz , 2A(max). Use the supplied 6 ft. hospital grade AC power cord. Improper power may cause electric shock or equipment damage. To avoid the risk of electric shock, this equipment must only be connected to a power supply with protective grounding.
Use the Audio In jack to connect an input sound device, such as a media player or microphone. This will allow sound to be added to video recordings. The Audio Out jack is for hearing playback of recorded sound.
The Pedal jacks (capture and record) are for connecting remote switching devices, such as a foot pedal or an endoscopic camera system’s control features.
FSN1949 - 01/201614 - English
Connect a Remote Control Device
The preferred way to record images and video with MDVR is by connecting a remote control device, such as a touch screen tablet. For specific instructions, please refer to the user guide that accompanies the remote control device that will be connected to MDVR.
Example:Touch screen tablet connection using a wireless router. For specific instructions, see the user guide for the remote control device that will be connected to MDVR.
Example: Direct wire touch screen tablet con-nection. For specific instructions, see the user guide for the remote control device that will be connected to MDVR.
FSN1949 - 01/2016 English - 15
Most features in the MDVR unit are intuitively handled by a remote control device, such as a touch screen tablet and interface software. Capture and record functions are designed for easy end user operation via the tablet interface. There are a few configuration settings that can only be accessed through MDVR’s front keypad and LCD. Following is a list of features found in MDVR, followed by the methods that are available for use.
MDVR Feature Main User Primary Operation Secondary Operation
Capture Image OR Staff Tablet Front panel keypad
Record Video OR Staff Tablet Front panel keypad
Enter Patient Info. OR Staff Tablet
View Recorded Files OR Staff Tablet
Play Recorded Files OR Staff Tablet
Send Files to Media OR Staff Tablet
Send Files to FTP OR Staff Tablet
Convert to DICOM OR Staff Tablet
Set File Type Installer or Admin. Tablet
File Server Access Installer or Admin. Tablet
Set Input Source/Port Installer or Admin. Tablet Front panel keypad
Time & Date Setting OR Staff Tablet Front panel keypad
DHCP Setup Installer or Admin. Tablet Front panel keypad
Select Input Resolution Installer or Admin. Tablet Front panel keypad
Delete Selected Files OR Staff Tablet
Delete All Files Installer or Admin. Tablet Front panel keypad
Control Device Setup Installer or Admin. Front panel keypad
Network IP Address Installer or Admin. Tablet Front panel keypad
Firmware Version Installer or Admin. Front panel keypad
Internal Space Avail. OR Staff Tablet Front panel keypad
DVD Space Available OR Staff Tablet Front panel keypad
USB Space Available OR Staff Tablet Front panel keypad
System Shutdown OR Staff Tablet Front panel keypad
Please consult the user guide for the remote control device connected to MDVR.
Methods of Operation
Front panel control keypad
FSN1949 - 01/2016
IPS700A2013-10-20 14:30
[Current Work]Video Recording
1. Network IP192.168.0.1
16 - English
Front Panel Control Keypad (OSD)
The preferred method of altering most features in the MDVR system is the remote control device, which is usually a tablet. A secondary method for altering most features is maneuvering through the menus on the small front panel LCD screen by using the control keypad.
Below are funtions and settings that are available through the MDVR front panel LCD and key-pad.
Home Screen The home screen shows the MDVR part number (IPS700A), the date in year-month-day format, and the time (24 hr.).
Other screens that are idle for 10 seconds will revert back to displaying the home screen.
Recording Select CAPTURE to save a still image.Select REC to begin video recording (red light starts). Select STOP to end video recording
Status Screens Press the top arrow to cycle through the list of system status information as described below.
1. Network IP is displayed.2. Firmware version is displayed.3. Internal disk storage size is displayed.4. Removeable disk media storage size is displayed.5. Removeable USB media storage size is displayed.6. Scaler version is displayed.
FSN1949 - 01/2016
System shutdownShutdown system
1. Input Source DVI
English - 17
Front Panel Control Keypad (OSD)
ShutdownPress left or right arrow to start the shutdown pro-cedure. Press ENTER to proceed with shutdown. To turn power off, reach behind the MDVR cabinet and turn off the power switch located on the back panel of the unit.
Menu Configuration Screens Press MENU to enter configure mode, then press the top arrow to cycle through the list of adjustments. Use the arrow keys and the ENTER key to configure each setting as described below.
1. Input SourcePress left or right arrow to cycle through source types. Press ENTER to finish.
2. Time SettingPress ENTER to begin.Press up or down arrow to select the first number of the year, then select ENTER. Continue until the year-month-day, and time (24 hr.) settings are complete. Press ENTER to finish.
3. DHCP SetupPress ENTER to begin.Press left or right arrow to turn DHCP on or off. Press ENTER to finish.
4. Res. SelectPress left or right arrow to cycle through input resolutions. Press ENTER to finish.
5. CTRL DevicePress left or right arrow to choose between wireless or wired (UART) control device connection. Press ENTER to finish, the system will reboot.
6. Auto AdjustPress ENTER to auto adjust analog settings.
7. Analog CSCPress left or right arrow to choose between RGB and YUV settings. Press ENTER to finish.
8. Audio InputPress left or right arrow to choose between Line In and Mic settings. Press ENTER to finish.
9. Pedal TypePress left or right arrow to choose pedal type 1-4. Press ENTER to finish.
FSN1949 - 01/201618 - English
General Specification
Input/Output Specification
Item Description Unit
Model IPS700A (Signal processor for Medical)
Input DVI‐D ,VGA, CVBS, S‐VIDEO Port
Output DVI‐D, VGA, CVBS Port
Control key 9 button (CAPTURE, REC, STOP, SELECT, UP, DOWN, PLUS, MINUS, MENU)
OSD language English
Power AC 100~240V / 50~60Hz , 2A(max)
Serial communication RS-232C, 115200 baud Rx
Network Ethernet TCP/IP 10/100 base TX (Auto sensing)
Compliance & Certifications FDA Class I, UL 60601-1, CAN/CSA-C22.2 No.601.1-M90, FCC Part 15 Class B, MDD Class I, IEC60601-1, EN60601-1-2, CCC & IEC60950-1
Size (H x D x W) 382 (15.039)x 354.2 (13.945) x 80 (3.149) mm/(inch)
Weight 4.8 / 10.582 Kg/Lbs
Item Type Signal Name Supported Resolution Application
Signal Input
VIDEO (BNC,SVHS) CVBS x 1SVHS(Y/C) x 1
NTSC / PAL Room Camera, SD Endoscopy
ANALOG (DSUB15) DSUB Analog x 1 Up to 1920x1080/60Hz
Endoscopic Camera
DIGITAL (DVI24) Digital DVI‐D x 1 Up to 1920x1080/60Hz
Endoscopic Camera
Signal Output
VIDEO (BNC) CVBS x 1 NTSC Surgical/Diagnostic Monitor
ANALOG (DSUB15) DSUB Analog x 1 Up to 1920x1080/60Hz
Surgical/Diagnostic Monitor
DIGITAL (DVI24) Digital DVI‐D x 1 Up to 1920x1080/60Hz
Surgical/Diagnostic Monitor
FSN1949 - 01/2016 English - 19
Input/Output Connector Specification
Pin No. Assignment Pin No. Assignment
1 Red 9 No Connection
2 Green 10 Ground-Sync
3 Blue 11 Ground
4 Ground 12 DDC Data
5 DDC 5V Standby 13 H.Sync
6 Ground-Red 14 V.Sync
7 Ground-Green 15 DDC Clock
8 Ground-Blue
Pin No. Assignment Pin No. Assignment
1 T.M.D.S. Data2 13 No Connection
2 T.M.D.S. Data2+ 14 +5V Power
3 T.M.D.S. Data2 Shield 15 GND
4 No Connection 16 Hot Plug Detect
5 No Connection 17 T.M.D.S. Data0
6 DDC Clock 18 T.M.D.S. Data0+
7 DDC Data 19 T.M.D.S. Data0 Shield
8 No Connection 20 No Connection
9 T.M.D.S. Data1- 21 No Connection
10 T.M.D.S. Data1+ 22 T.M.D.S. Clock Shield
11 T.M.D.S. Data1 Shield 23 T.M.D.S. Clock+
12 No Connection 24 T.M.D.S. Clock
Pin No. Assignment
1 Composite
2 Ground
1 S-VIDEO /Y (Luminance)
2 S-VIDEO /C (Chrominance)
3 Ground
FSN1949 - 01/201620 - English
Input/Output Timing
Resolution Horizontal Frequency (KHz) Vertical Frequency (Hz) Pixel clock (MHz)
640 x 350 @70Hz 31.469 70.087 25.175
640 x 400 @60Hz 31.469 59.941 25.175
640 x 480 @60Hz 31.469 59.940 25.175
640 x 480 @75Hz 37.500 75.000 31.500
800 x 600 @56Hz 35.156 56.250 36.000
800 x 600 @60Hz 37.879 60.317 40.000
800 x 600 @72Hz 48.077 72.188 50.000
800 x 600 @75Hz 46.875 75.000 49.500
1024 x 768 @60Hz 48.363 60.004 65.000
1024 x 768 @75Hz 60.023 75.029 78.750
1152 x 864 @60Hz 54.348 60.053 80.000
1152 x 864 @75Hz 67.500 75.000 108.000
1280 x 720 @60Hz 45.000 60.000 74.250
1280 x 960 @60Hz 60.000 60.000 108.000
1280 x 1024 @60Hz 63.800 60.000 108.000
1280 x 1024 @75Hz 79.976 75.025 135.000
1600 x 1200 @60Hz (**) 74.077 59.981 130.375
1920 x 1080 @60Hz 67.500 60.000 148.500
DVI, VGA input timing
DVI, VGA output timing
Resolution Horizontal Frequency (KHz) Vertical Frequency (Hz) Pixel clock (MHz)
720 x 480 @60Hz 31.500 60.000 27.000
1280 x 720 @60Hz 45.000 60.000 74.250
1920 x 1080 @60Hz 67.500 60.000 148.500
FSN1949 - 01/2016 English - 21
Power Consumption
Recording Time
Mode Consumption (W) State
Record 44 BLURAY data backup
Record 35 HDD recording
Normal 32 Standby
Off 0 Power off
Record Device Hours Size Resolution Source
Internal disk
45.5 1 Terabyte 1080p
Surgical camera83.3 1 Terabyte 720p
500 1 Terabyte 480p
Backup Device Hours Size Resolution Source
USB
1 22 Gbyte 1080p
Internal disk
1 12 Gbyte 720p
1 2 Gbyte 480p
Blu-ray
1.1 25 Gbyte 1080p
2 25 Gbyte 720p
12 25 Gbyte 480p
DVD
0.15 4.7 Gbyte 1080p
0.3 4.7 Gbyte 720p
2.3 4.7 Gbyte 480p
FSN1949 - 01/2016
355 mm / 13.98 in.
382
mm
/ 15
.04
in.
80 m
m /
3.15
in.
22 - English
Mechanical Drawing
FSN1949 - 01/2016 English - 23
Troubleshooting
Problem Possible Solution
No power Check fuse in AC Inlet. If fuse has failed, replaced with similarly rated new part.
Will not record Verify that there is sufficient space available on the internal disk.
No response from MDVR Re-boot the system.
Disc or USB failure Make sure that the media being used is not write protected.Verify that there is sufficient space available on the media.Erase unnecessary files or replace the disc.
Cleaning Instructions
CAUTION: Do not apply or spray liquid directly on the Video Image Processor chassis as excess liquid may cause damage to internal electronics. Instead, apply the liquid to the cleaning cloth first.
Note: The Video Image Processor chassis is not disinfected or packed in a sterile environment. Follow your hospital protocol in case the Video Image Processor chassis needs to be disinfected prior to installation.
Note: Follow your hospital protocol for the handling of blood and body fluids.
Note: Take care not to damage or scratch the front LCD panel. Be careful with rings or other jew-elry that can touch the front filter. Do not apply pressure on the front filter or LCD panel.
1. Clean the exterior of the Video Image Processor chassis using a soft cotton cloth, lightly moistened with a recognized cleaning product for medical equipment.
2. Repeat with water only.3. Wipe dry with a dry cloth.
The chassis has been tested for resistance to the following products:
hypochlorite diluted with water between1:10 and 1:100)
Thank you for choosing our product.
Service
Please contact our customer service if you need any information or help with our products.
Warranty
One year, parts and labor.
EC RepresentativeFORESEESON GmbHIndustriestrasse 38a, 63150 Heusenstamm, GermanyTel. +49(0)6104-643980 FORESEESON UK Ltd.Unit 71, Barwell Business ParkLeatherhead Road, Chessington, SurreyKT9 2NY, UK Tel. +44-(0)208-546-1047 FORESEESON KOREA404B, Pangyoinnovalley B, 253 Pangyo-ro, Bundang-gu,Seongnam-si, Gyeonggi-do, Korea, 463-400Tel. +82(31)8018-0780 Fax. +82(31)8018-0786
FORESEESON (Shanghai) Medical Equip. Co., Ltd.Room 307, 3F No. 56, 461 Hongcao RoadCaohejing Development DistrictXuhui, Shanghai 200233 Tel: 86-21-6113-4188
FORESEESON CUSTOM DISPLAYS, INC.2210 E. Winston Road, Anaheim, CA 92806 USATel. 1-714-300-0540 Fax. 1-714-300-0546
D&T Inc.Jang-dong, Daedeok Valley, 26-121, Gajeongbuk-ro, Yuseong-gu, Daejeon, Korea, 305-343Tel. + 82(42)360-8000 Fax. +82(42)360-8005
Specifications are subject to change with or without notice.
www.fsnmed.com