8031
Non-ContactSafety PhaseIndicator
8031F
INSULATION TESTERS3165/3166 34313161A 3131A 3132A
3 ranges3 rangesegatlovTest egnar1
Appearance
Rated voltage1000V(2000MΩ)(3166)500V(1000MΩ)(3165)
250V(100M500V(200M
1000V(400M
Ω)Ω)Ω)
250V(200MΩ)500V(200MΩ)
1000V(2000MΩ)
250V(100M500V(200M
1000V(400M
Ω)Ω)Ω)
15V(20M500V(100M
ΩΩ)
)
Con�nuity ranges - -
-
- 2/20Ω 3/500ΩAC Voltage ranges -
-600V600V 600V
600V600V
Back light --DC Voltage ranges --
Power source R6/LR6 × 4 R6/LR6 × 4 R6/LR6 × 4 R6/LR6 × 6 R6/LR6 × 6Dimensions (L)×(W)×(D)mm 90×137×40 90×137×40 97×156×46 167×185×89 106×160×72Weight (Approx.) 330g 340g 430g 860g 560g
Weight(Approx.)
Dimensions (L)×(W)×(D)mm 167×185×89
Appearance
Test voltage
AC Voltage ranges
DC Voltage ranges
Rated voltage(Max.measurement value)
(Max.measurement value)
Con�nuity ranges
DC Voltage ranges
Back light
-
-
3 segnar 4 ranges
250V(2000MΩ)500V(2000MΩ)
1000V(2000MΩ)
20/200/2000Ω600V
3005A/3007A 3552BT*3551/35523021A 3022A 3023A Digital Insula�on/Con�nuity Testers
Analogue Insula�on/Con�nuity TestersAnalogue Insula�on Testers
970g(3005A)990g(3007A)
2 ranges
PHASE INDICATORS LIGHT METERPhase Indicators
8030 8031/8031F 8035
Appearance
Dimensionsmm)D(×)W(×)L(
Weight ).xorppA(
Opera�onal egatlovFuse
Time limit forcon�nuous
Frequency esnopser
Applicable standards
Power source
droC
32×95×28
g002
200 - 480V AC-
200V : within 60 minutes480V : within 4 minutes
20 - 400Hz
-
m1-
(L1:red L2:white L3:blue)
63×16×211
g083
70 - 1000V AC-
-
45 - 66HzIEC 61010-1 CAT 600V
CAT 1000VIEC 61326, IEC 61557-1,-7IEC
R6/LR6 × 470cm
(L1:red L2:white L3:blue)
04×57×601
g053
110 - 600V AC8031F
>500V : within 5 minutes
zH06/05
-1.5m
(L1:red L2:white L3:blue)
(CE Type/8031F)IEC 61010-1 CAT 600V
Appearance
Dimensions (L)×(W)×(D)mmWeight (Approx.)
Applicable standardsPower source
RangesAccuracy
Angle devia�on fromcosine characteris�cs
Rela�ve spectralsensi�vity characteris�cs
Response �me
Power source R6/LR6 × 8-
105×158×70
1000V(2000MΩ)
125V(200MΩ)250V(2000MΩ)500V(2000MΩ)
40/400Ω
-20 - -600V20 - 600V
20 - 600V
600g
R6/LR6 × 6-
105×158×70
50V(200MΩ)100V(200MΩ)
250V(2000MΩ)500V(2000MΩ)
40/400Ω
-20 - -600V - 20 600V
- 20 600V
600g
R6/LR6 × 6
6 ranges
97×156×46
USB, Bluetooth
100V(200MΩ)
250V(500MΩ)125V(250MΩ)
1000V(40GΩ)
50V(100MΩ)
500V(20GΩ)
40/400/4000Ω
490g
R6/LR6 × 4
97×156×46
USB(3552)
1000V(4000MΩ/40GΩ*1)
50V(100MΩ)100V(200MΩ)
250V(500MΩ)125V(250MΩ)
500V(2000MΩ/20GΩ*1)
40/400/4000Ω
490g
R6/LR6 × 4
-2.0 - -600V 2.0 - 600V
2.0 - 600V -2.0 - -600V
2.0 - 600V
2.0 - 600V
-
40/400Ω
105×158×70
1000V(2000MΩ)
100V(200MΩ)250V(2000MΩ)500V(2000MΩ)
-20 - -600V 20 - 600V
20 - 600V
600g
R6/LR6 × 6
(3007A)Communica�on interface
*Please contact us with inquiries about the purchase of 3552BT.
Bluetooth
*1 3552
Light Meter5204
10°±1.5%30°±3%
60°±10%80°±30%
169×63×37210g
IEC 61326 , JIS C 1609-1:2006R6/LR6×2
Devia�on from spectral luminousefficiency:9% or less
Auto range:5s or lessManual range:2s or less
0.0 - 199900 lx±4%rdg±5dgt(23°C±2°C)
Appearance
(Max.measurement value)
Test voltage
rangesAC/DC Voltage
Back light
Current
Memory
Capacitance
177×226×100 177×226×100
gk9gk8gk9.1gk7.1
ecruosPower
(L)×(W)×(D)mmDimensions
).xorppA(Weight
3025A 3125A 3127 3128Digital High Voltage Insula�on Testers
5 ranges 5 ranges4 ranges 6 ranges(Variable)
250V(100MΩ)500V(1000MΩ)
1000V(2GΩ)2500V(100GΩ)
250V(100MΩ)500V(1000MΩ)
1000V(2GΩ)2500V(100GΩ)
5000V(1000GΩ)
500V(500GΩ)1000V(1TΩ)
2500V(2.5TΩ)5000V(5TΩ)
10000V(35TΩ)12000V(35TΩ)
30 - 600V AC/DC30 - 600V AC/DC30 - 600V AC/DC30 - 600V AC/DC
-- 5.0nA - 2.40mA0.00nA - 5.50mA
--
-- 5.0nF - 50.0μF5.0nF - 50.0μF
41RL 8× LR14 × 8 Rechargeable lead storageba�ery (12V)
Rechargeable lead storageba�ery (12V)
380×430×154*Instrument and Hard case
330×410×180*Instrument and Hard case
3121B 3122B 3123A 3124A
HIGH VOLTAGE INSULATION TESTERSAnalogue High Voltage Insula�on Testers
Appearance
gk5.1gk11.7kg1.6kg
scalesDual resistance
Test voltageRated voltage(Max. measurement value)
ecruosPower
08×041×00208×041×002177×226×100 177×226×100Dimensions mm)D(×)W(×)L(
).xorppA(Weight
elbairaV2 segnar
2500V(100G )Ω 5000V(200GΩ) 5000V(200G10000V(400G
Ω)Ω)
1000V(100MΩ)1k - 10kV(100GΩ)
LR14 × 8 LR14 × 8 R6/LR6 × 8 Ni-MH rechargeable ba�ery(1.2V) × 8
1 range
250V(9.99GΩ)500V(99.9GΩ)1000V(199GΩ)2500V(999GΩ)5000V(9.99TΩ)
SENSORS
Load tnerruc
daoL current(For Power Meter)
8121 8122 8123
8124 8125 8126 8127 8128 81338130
Voltage Ior Leakage currentLeakage & Load current8309 817881778146 8147 8148
Rated current(AC)/voltage(AC) 30A 100A 10A 10A70A 600V
Appearance
100A 500A 1000A
1000A 500A 200A 100A 5A(Max.50A) 3000A1000ARated current(AC)
Appearance
-φ24 φ40 φ68 φ40 φ68φ24 φ40 φ55
φ68 φ40 φ40 φ24 φ170φ110φ24
Conductor size(MAX.mm)
Conductor size(MAX.mm)
Rated voltage
www.kew-ltd.co.jp
Analogue sretemitluM latigiD Mul�meters
latigiD Mul�meters
MULTIMETERS
DC VAC V
DC A
Appearance
AC A
ResistanceCon�nuity buzzerCapacitanceFrequencyBack lightLogging memoryMeasurementcategories
sourcePower
Dimensions (L)x(W)x(D)mm
Weight (Approx.)
1061/10621051/1052
CapacitanceFrequency
Measurementcategories
192×90×49192×90×49560g 560g
Con�nuity buzzer
Back lightLogging memory
Appearance
Resistance
sourcePower(L)×(W)×(D)mmDimensions
(Approx.)Weight
600mV - 1000V 50mV - 1000V50mV - 1000V600mV - 1000VDC V
AC VDC AAC A
600μA - 10A 500μA - 10A600μA - 10A 500μA - 10A
(1052)
LEAKAGE CLAMP METERSLeakage Clamp Meters
24322431 2433/2433R 2434 2413F/2413R
AC AAC VResistanceBack light
Frequency filterMeasurement categoriesPower sourceDimensions (L)×(W)×(D)mmWeight (Approx.)
Appearance
Conductor size(MAX.mm)Frequency response
Pea oh ldk
1062PEAKHOLD
1021R
CAT 300VCAT 600V
155×75×40250g
600mV - 600V600mV - 600V
6A - 10A6A - 10A
-
R03/LR03 × 2
1020R
155×75×40250g
600mV - 1000V600mV - 1000V
--
-
R03/LR03 × 2
CAT 300VCAT 600V
CAT 1000V
2413R2433R
R6/LR6 × 4 R6/LR6 × 4
4mA - 100A
185×81×32290g
20Hz - 1kHzφ40
---
CAT 300VR03/LR03 × 2
20mA - 200A
149×60×26120g
40 - 400Hzφ24
-----
CAT 300VLR-44 × 2
40mA - 400A
185×81×32270g
20Hz - 1kHzφ40
---
CAT 300VR03/LR03 × 2
169×75×40220g
40 - 400Hzφ28
400mA - 100A----
CAT 300VR03/LR03 × 2
250×130×50570g
40Hz - 1kHzφ68
200mA - 1000A--
(2413R)
CAT 300V6F22 × 1
1011/1012
600mV - 600V6 - 600V
600μA - 10A600μA - 10A
--
280g161×82×50R6/LR6 × 2R6/LR6 × 2
1009
400mV - 600V400mV - 600V400μA - 10A400μA - 10A
--
CAT 600VCAT 1000V
CAT 600VCAT 1000V
CAT 300VCAT 600VCAT 300V
280g161×82×50
-
-
1030
400mV - 600V4 - 600V
-
CAT 600V
100g
190×39×31
LR44 × 2
1110
0.3 - 600V12 - 600V
60μA - 300mA
-
----
CAT 300VCAT 600V
280g
140×94×39
1109S
0.1 - 1000V10 - 1000V
50μA - 250mA
-
-----
-
150×100×47
330g
R6×2/6F22 × 1
1012
2001A
2000A
Ø6
Ø10
340mV - 600V3.4 - 600V
60A(2000A)100A(2001A)60A(2000A)
100A(2001A)
2000A/2001A
-
--
128×87×24(2000A)128×92×27(2001A)
210g(2000A)220g(2001A)
R03/LR03 × 2
CAT 300VCAT 600V
Ø12
2012RA
600mV - 600V6 - 600V
60/120A
60/120A
--
R03/LR03 × 2
128×92×27
220g
CAT 300VCAT 600V
1019R
600mV - 600V6 - 600V
-
-
-
-CAT 300VCAT 600V
135g
126×85×18
CR2032 × 1
-
R6/LR6 × 2
2500/2510 2010 2033 2046R 2055/2056R 2003A 2009R 2300RTester
Fork CurrentDC MilliampClamp Meters AC/DC Clamp Meters
DC/AC A:0-400.0ADC/AC V:0-400.0V
CLAMP METERSAC Clamp Meters
Appearance
Conductor size(MAX.mm)
Frequencyresponse
AC AAC VDC VResistanceCon�nuity buzzerFrequencyPeak holdMax/Min
Measurementcategories
Power source
Dimensions(L)×(W)×(D)mm
Weight (Approx.)
Appearance
Conductor size(MAX.mm)
Frequencyresponse
AC ADC AAC VDC V
ResistanceCon�nuity buzzerFrequencyBack lightPeak holdMax/Min
Measurementcategories
Communica�oninterface Bluetooth(2510)
Power source
Dimensions(L)×(W)×(D)mm
540gWeight (Approx.)
φ55
DC20Hz - 1kHz400/2000A
40 - 750V40 - 1000V
-
-
-
CAT 600VCAT 1000V
250×105×49
2056R
2210R
R03/LR03 × 2
30 - 3000A
φ150
------
45 - 500Hz
120×70×26(Display unit)
φ8.5mm Approx.(Cable diameter)
300g
CAT 600VCAT 1 00V
R03/LR03 × 2
------
45 - 500Hz
120×70×26(Display unit)
φ5.5mm Approx.(Cable diameter)
200g
CAT 600VCAT 1 00V
2204R
4 - 400A
φ70
2608A
50/60Hz
6 - 300A
60V
R6/LR6 × 1
275g
φ33
150 - 600V
----
193×78×39
CAT 300VCAT 600V
2117R
R03/LR03 × 2
60 - 1000A
60/600V
40 - 1kHz
220g
φ33
60/600V
---
204×81×36
CAT 300VCAT 600V
2031
20/200A
LR-44 × 2
φ24
-------
147×59×26
CAT 300V
40Hz - 1kHz
100g
40 - 400Hz
2007R
600/1000A
220g
φ33
600V
---
R03/LR03 × 2
204×81×36
CAT 300VCAT 600V
600V
R03/LR03 × 2
60 - 1000A
60/600V
40 - 1kHz
60/600V
CAT 300VCAT 600V
2127R
φ33
-
204×81×36
230g
2200R
22002200R
R03/LR03 × 2
φ33
40 - 1000A4 - 600V
400V - 600V
---
190×68×20
*1 2200R*2 2200
40 - 1kHz(AC A)*1
45 - 65Hz(AC A)*2
45 - 500Hz(AC V)
120g
CAT 300V(AC A)*1
CAT 600V(AC A)
CAT 300V(AC/DC V)
CAT 600V(AC/DC V)
2002R
2002PA2002R
400/2000A
R6/LR6 × 2
φ55
40 - 750V40 - 1000V
-
-
247×105×49
40Hz - 1kHz
470g
CAT 600VCAT 1 00V
*4
the PEAK mode,the auto-ranging feature is disabled and measuring ranges are fixed as follows.*4 In*3 External power is available.(2510 only)
4
DC
20/120mA
290g(2500)310g(2510)
φ6
-
--
---
--
111×61×40(Display unit)
104×34×20(Sensor)
R6/LR6 × *3
400/2000A
220g
φ7.5
DC40Hz - 2kHz200mA - 20A
--
-----
-
-
--
142×64×26(Display unit)
153×23×18(Sensor)
2/20A
6LR61 × 1
100g
φ24
DC20Hz - 1kHz
40/300A
--
----
- - -
--
CAT 300V
147×59×25
40/300A
LR-44 × 2
300g
φ33
DC40 - 400Hz
600A
6 - 600V600mV - 600V
CAT 600V
243×77×36
600A
R03/LR03 × 2
310g
φ40
DC40 - 400Hz600/1000A
6 - 600V600mV - 600V
(2056R)
CAT 600V
254×82×36
600/1000A
R03/LR03 × 2
530g
φ55
DC40Hz - 1kHz400/2000A
400/750V400/1000V
--
-
(Max)-
CAT 600VCAT 1000V
250×105×49
400/2000A
R6/LR6 × 2 R6/LR6 × 2
110g
φ10
DC50/60Hz
100A
--
-----
-
-
CAT 300V
161×40×30
100A
R03/LR03 × 2
2510Bluetooth
LOOP/PSC Testers
110 - 260V ±2%rdg±4dgt 0 - 500V ±2%rdg±4dgtVoltage
- R6/LR6 × 6Power source
(Approx.)Weight 750g 860g
Appearance
25A/2.3A/15mA 6A/2A/15mAcurrentAC test20/40/280ms 40/20/500msperiodAC test
200/2000A/20kA 2000A/20kArangesPSC- 2000A/20kA(L-N<20Ω)PFC ranges
230V +10%, -15% 50 - 500VvoltageOpera�ng
4118A 4140
LOOP/PSC TESTERS
20/200/2000ΩLoop impedance ranges 20/200/2000Ω(ATT*)
ATT*:An�-Trip Technology
IEC 61010-1 CAT 300VIEC 61010-031
IEC 60529(IP54), IEC 61326IEC 61557-1, 3, 7, 10Applicable standards IEC 61010-031
IEC 61557-1, 3IEC 60529(IP54)
61010-1 CAT 300VIEC
4202Bluetooth
4200/4202 4300Earth Clamp Testers Simplified Earth Tester
EARTH TESTERS
R6/LR6 × 6 R6/LR6 × 6 R6/LR6 × 8
600g 550g 900g105×158×70 105×158×70 167×185×89
IEC 61010-1 CAT 300VIEC 61010-031IEC 61557-1, 5
IEC 60529(IP54)
IEC 61010-1 CAT 300VIEC 61010-031IEC 61557-1, 5
IEC 60529(IP54)
IEC 61010-1CAT 300V
CAT 150V
IEC 61010-031, IEC 61557-1, 5IEC 61326-1, IEC 60529(P54)
2/20/200/2000/20k/200kΩ2/20/200/2000/20k/200kΩ
50V AC(800 data)
20/200/2000Ω-
200V AC
12/120/1200Ω-
30V AC-
LR6 × 6
690g121×188×59
IEC 61010-1 CAT 100 VCAT 150 V, CAT 300 V
IEC 61010-2-030, IEC 61010-031IEC 61557-1, -5, IEC 60529 (IP67)
IEC 61326-1, -2-2 (EMC)
20/200/2000Ω
300V AC/300V DC-
----
(Approx.)Weight
Earth resistanceEarth resis�vity ρEarth egatlovMemory func�onBack light
Applicable standards
Power source
Appearance
Dimensions (L)×(W)×(D)mm
TestersEarth
EARTH TESTERS4102A/4102A-H* 4105A/4105A-H* 41064105DL/4105DL-H*
780g 220g(Approx.)Weight
φ32 -Conductor size(MAX.mm)20/200/1500Ω 200/2000ΩEarth resistance
- 300V AC/DCEarth egatlov100/1000mA/10/30A -AC A
-Noise check(100 data) -Memory func�on
Back light
IEC 61010-1 CAT 300VIEC 61010-2-032
IEC 61326
IEC 61010-1 CAT 300VIEC 61010-031IEC 61557-1, 5
IEC 61326-1IEC 60529(IP40)
Applicable standards
R6/LR6 × 4 R6/LR6 × 2Power source246×120×54 232×51×42Dimensions (L)×(W)×(D)mm
Appearance
167×185×89 84×184×133Dimensions (L)×(W)×(D)mm
KT170/KT171
KEWTECH BrandpgDi ital Clam Meters
responseAC A
AC VDC V
source
(Approx.)
KT200/KT203
φ30
50/60HzA004/04
40/400AV006/004V006/004
CAT 300V(AC A)CAT 600V
R03/LR03 × 2184×69×39 (KT200)187×69×39 (KT203)
190g(KT200)200g(KT203)Weight
Power
Measurementcategories
Dimensions(L)×(W)×(D)mm
ResistanceCon�nuity buzzer
Frequency
DC A (KT203 only)
Conductor size(MAX.mm)
Appearance
Voltage Testers
LEDLCD (KT171 only)
Weight (Approx.)
Dimensions(L)×(W)×(D)mm
Power source
Applicable standards
Con�nuity test
Phase rota�on
Single-pole phase
Voltagetest
Appearance
IEC 61557-7
12/24/50/120/230/400/690V300.0/690V
100-690 AC(50/60Hz)
0-400kΩ +50%
195g
246×64×26
Three-phase 4wire system200-690V AC(50/60Hz)
R03/LR03 × 2
IEC 61010-1 CAT 690VCAT 600V
IEC 61243-3
IEC 60529(IP65)
-Communica�on interface Bluetooth(4202)
H* Hard case type
VOLTAGE DETECTORVoltage Detector
AC 90 - 1000 V (Lo sensi�vity)AC 20 - 1000 V (Hi sensi�vity)
5711
Appearance
DimensionWeight (Approx.)
153(L) × φ20mm40g
Opera�ng voltage
Frequency range 50/60Hz
Applicable standardsIEC 61010-1 CAT 600V
CAT 1000VPower source R03/LR03 × 2
www.kew-ltd.co.jp
MULTI FUNCTION TESTERSMul� Func�on Testers
6010B 6016 6024PV60186011A
ytiunitnoCnoitalusnI
).xorppA( )Weight .Weight
ecruosPower
Applicable standards
- -250/500/1000V 250/500/1000V
--
--
-
--
12/120/1200Ω0 - 600V AC
--
--
-
g0001
130×183×100
R6/LR6 × 8
IEC 61010-1 CAT 600VIEC 61010-031
IEC 61557
20/200ΩV0001/005
20/200Ω
-
-
100 - 250V AC-
g048
115×175×86
R6/LR6 × 8
IEC 61010-1 CAT 300VIEC 61557-1,2,3,4,6,10
IEC 60529(IP40)
LoopPV Insula�on
impedanceRCDPSCEarth resistance
Phase rota�on200mA con�nuity test currentAuto dischargesLIVE circuit warningPC communica�on
Appearance
Dimensions(L)x(W)x(D)mm
ATT*:An�-Trip Technology
AC/DC voltage
20/200/2000ΩV0001/005/052
20/200/2000Ω-
100 - 250V AC-
- -
-
g0011
130×183×100
R6/LR6 × 8
IEC 61010-1 CAT 300VIEC 61010-031
IEC 61557IEC 60529(IP54)
-
20/200/2000ΩV0001/005/052
20/200/2000Ω(ATT*)
20/200/2000Ω25 - 500V AC
g0531
136×235×114
R6/LR6 × 8
IEC 61010-1 CAT 300V(500V L to L)
IEC 61010-031IEC 61557-1,2,3,4,5,6,7,10
IEC 60529(IP40)IEC 61326(EMC)
500/1000V
20/200/2000Ω600V AC/1000V DC
900g
84×184×133
LR6 × 6
IEC 61010-1 CAT 300VCAT 600V
IEC 61010-2-030IEC 61010-031
IEC 60529(IP54)IEC 61557-1,-2,-5,-10
IEC 61326-1,2-2
PORTABLE APPLIANCE TESTERRCD Testers
RCD TESTERS
0145
80 - 450Vsm1
AUTO,2/1×,1×,5×
g569
R6/LR6 × 8
15/30/50/100mA(×5)15/30/50/100/200/500mA
(×1,×1/2, AUTO)
100V ±10%, 200V +32%/-10%, 400V ±10%(50/60Hz)
IEC 61010-1CAT 300V/CAT 400V
IEC 61557-1, 6, IEC 60529(IP54)
-
A6045
sm1
,CD×,5×,1×,2/1× AUTO-
g008
-
Am005/003/002/03/02/01
230V +10%, -15%(50Hz)
IEC 61010-1, CAT 300VIEC 61557-1, 6
IEC 60529(IP54)
mm)D(×)W(×)L(Dimensions
).xorppA(Weight
Power source
tnerrucRated tripping
Fault condi�on se�ngsVoltage measurement
noituloserLowest0 and 180 degree phaseangle switch
Opera�ng voltage
Constant current tes�ng
Appearance
Check opera�on ofDC sensi�ve breakers
Applicable standards
Appearance
Protec�ve conductorresistance
Insula�on resistance
Leakage current
Power sourceSource voltage
Weight (Approx.)
Dimensions(L)×(W)×(D)mm
voltageAC
Applicable standards
RCDMemory func�onBack lightPC communica�onPrinter output
Portable Appliance Tester6205
20mALoad current 10.00A rms
20Ω
20MΩ(250/500V)
30 - 270V
USB
(999 data)
230V -15% - +10%
930g
AS/NZS 3760:2010IEC/EN61010-1 CAT 300V
IEC/EN61010-2-030IEC/EN61010-031
EN61326-2-2
261×104×57
LR6×6167×186×89167×186×89
POWER METER POWER QUALITY ANALYZER
Power Meter6305
Power Quality Analyzer6315
range[RMS] 150.0/300.0/600.0VVoltage±0.2%rdg±0.2%f.s.(sine wave, 45 - 65Hz)accuracyVoltage
Weight 175(L)×120(W)×65(D)mm / 800g Approx.Dimensions /
Current range[RMS] 10.00/50.00/100.0/250.0/500.0A/Autosensor MODEL8125)(with clamp
Communica�on Interface USB, BluetoothPC Card type SD cardPower supply AC100 - 240V (50/60Hz)/LR6×6
connec�ons 1P2W, 1P3W, 3P3W, 3P3W3A, 3P4WWiring
LOGGERS
Ior LOGGER
5020
Communica�on Interface USB
Dimensions 111(L)×60(W)×42(D)mm
Recording mode Normal, Trigger, Capture,Power quality analysis
Weight (Approx.) 265g
Power supply External supply DC9V/LR6×4
3 channel inputs for the simultaneousrecording of Leakage Current, LoadCurrent and Voltage
5010
Communica�on Interface USB
Dimensions 111(L)×60(W)×42(D)mm
Recording mode Normal, Trigger, Capture
Weight (Approx.) 265g
Power supply External supply DC9V/LR6×4
3 channel inputs for the simultaneousrecording of Leakage and Load Current
For inquires or orders :
Safety Warnings : Please read the "Safety Warnings" in the instruction manual supplied with the instrument thoroughly and completely for correct use. Failure to follow the safety rules can causefire, trouble, electrical shock, etc. Therefore, make sure to operate the instrument on a correct power supply and voltage rating marked on each instrument.
In consideration of the environment, vegetable oil ink and recycled paper were used in this publication. ●The contents of this leaflet are subject to change without notice.
2-5-20, Nakane, Meguro-ku, Tokyo, 152-0031 JapanPhone:+81-3-3723-0131Fax:+81-3-3723-0152E-mail:[email protected]
KYORITSU ELECTRICALINSTRUMENTSWORKS, LTD.
www.kew-ltd.co.jp19.07 F
Wiring connec�ons 1P2W, 1P3W, 3P3W, 3P3W3A, 3P4W
320×240(RGB) Pixels , 3.5- inch Color TFT displayDisplay
Communica�on Interface USB, Bluetooth
Current range[RMS] 500mA - 3000ACurrent accuracy ±0.2%rdg±0.2%f.s.+ Accuracy of Clamp sensor
Voltage accuracy
Voltage range[RMS] 600/1000V
PC Card type SD cardApplicablel standards IEC61000-4-30 Class SPower supply AC100 - 240V (45 - 65Hz)/LR6×6Dimensions / Weight 175(L)×120(W)×68(D)mm / 900g Approx.
Measurements & ParametersMeasurements & Parameters
Voltage, Current, Frequency, Ac�ve power, Reac�ve power,Apparent power, Energy, Power factor(cos θ), Demand,Harmonics,Quality(Swell/Dip/Interrup�on,Transients, Inrush Current, Unbalance Rate, Flicker)
Ior Logger5050
Wiring connec�ons 1P2W, 1P3W, 3P3W, 3P4W
10.000/100.00/1000.0mA/10.000A/AUTOIor rangeVoltage range 1000.0VCommunica�on interface USBPC Card type SD cardPower supply AC100 - 240V (50 - 60Hz)/LR6×6Dimension/Weight 165(L)×115(W)×57(D)mm / 680g Approx.
Measurements andParameters
Power quality and powerconsumption aresimultaneously recordable
Bluetooth
Quickly find electric leakageswith less time and more productivity.
lor : Leakage current (Trms) with resis�ve components onlylo : Leakage current (Trms) with basic wave of 40 - 70Hzlom : Leakage current (Trms) including harmonic componentsV : Reference voltage (Trms) with basic wave of 40 - 70HzVm : Reference voltage (Trms) including harmonic componentsR : Insula�on resistance, Frequency(Hz), Phase angle(θ)
Current accuracy ±0.2%rdg±0.2%f.s.+ Accuracy of Clamp sensor(sine wave, 45 - 65Hz)
Bluetooth
Voltage, Current, Frequency, Ac�ve powerApparent power, Reac�ve power, Ac�ve energy,
Neutral current,DemandApparent energy, Reac�ve energy, Power factor (cos θ),
600.0V Range : (sine wave 40-70Hz)10% - 150% against 100V or more of nominal V : Nominal V±0.5%Out of above range : ±0.2%rdg±0.2%f.s.
1000V Range : ±0.2%rdg±0.2%f.s.(sine wave 40-70Hz)