Page 1: GAS COUNTER TOP CONVECTION STEAMER - … · GAS COUNTER TOP CONVECTION STEAMER SPECIFICATIONS: Shall be a Solaris Model SX-5G, convection steamer with gas fired steam generator.AGA/CGA

G

Customer Service (570) 497-5477 - Fax (888) 388-6017 - www.solarissteam.com

GAS COUNTER TOP CONVECTION STEAMER

SPECIFICATIONS:Shall be a Solaris Model SX-5G, convection steamerwith gas fired steam generator. AGA/CGA and NSFCERTIFIED. The cavity shall be 5 pan capacity. Thesteamer shall be constructed of a satin finish stainless steel,type 304. The cooking chamber is a one piece all welded,type 316, stainless steel with coved corners. The heavyduty door shall have an inner line of stainless steel with a fullperimeter gasket seal, an outer liner of one piece all weldedstainless steel, and a positive lock and seal mechanism withspring release. The compartment shall be provided withremovable stainless steel pan supports. A stainless steeldrip trough shall be integrally connected to drain to collectcondensate when the door is opened.

The control housing, constructed of stainless steel witha full access removable panel contains the controls whichinclude a illuminated three way power switch(On/Off/De-lime), a pilot ready light, a pilot cooking light, an ignitionlight, a 60 minute electric timer which sounds an audiblesignal at the end of the cooking cycle, solid state generatorcontrols, and electronic ignition. Steam flow to the cookingchamber shall be cut off when the door is opened andreactivated when the door is closed.

Standard features include automatic generator blowdown, de-lime mode power setting and a de-lime port for thegenerator which is located on the right side panel. The unitalso comes with split water connections for simple hook upfor a treated water system. Steamer is mounted on 4" highstainless steel adjustable legs.

Pan Capacity

ModelPan Depth

1" 2-1/2" 4" 6"

SX-5G 10 5 3 2

OPERATION SHALL BE BY:

A gas fired, stainless steel steam generator operating at 0 psi (0 kPa) and rated at 45,000 BTU.

The generator shall be equipped for operation on:

Natural GasLP Gas

The controls shall be equipped for operation on:

120 VAC, 1 Phase, 50/60 Hz

OPTIONAL ITEMS AT EXTRA COST:

220 VAC, 1 Phase, 50/60 Hz controls120 minute timerCorrectional packageHigh sensitivity level controls ( R.O. water)Flanged feetRL-28G stand

Project ID#:

REV 5/08

Page 2: GAS COUNTER TOP CONVECTION STEAMER - … · GAS COUNTER TOP CONVECTION STEAMER SPECIFICATIONS: Shall be a Solaris Model SX-5G, convection steamer with gas fired steam generator.AGA/CGA

DETAILS AND DIMENSIONS

As continued product improvement is a policy of Solaris, specifications are subject to change without notice.

SHIPPING WT.

SX-5G PropaneNatural

BTU/HR.

MODEL

kW/HR. SUPPLY PIPE PRESSURE (W.C.)3

[76]

MIN. CLEARANCE*

LH RH BACK

[203]

8

[152]

6

MIN

.4

[102

]

1 [2

5]

D

G

1.75

[44]

4 [1

02]

C 23.1

9 [5

89] 40

.38

[102

6]

5 [1

27]

16.7

5 [4

25]

6484R5

IN [mm]

32 [8

13]

FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.Water which fails to meet these standards should be treated by installation of water conditioner.

local water treatment specialist and have the water analyzed. Your water supply must be within these general guidelines:Water quality is the major factor affecting the performance of your appliance. If you are unsure of water quality, consult a

GENERATOR WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa)

24" maximum length before open air gap opening. (No bends or elbows)

GAS CONNECTION: 3/4"IPS supply line required. A gas shut-off valve must be installed in supply piping

CONDENSING WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa)

Unless otherwise specified, Field Wire Electrical Connection to be 120 Volts, 60 Hertz single phase withgrounding wire. Furnished with 6 foot cord with 3 prong plug. Maximum amps 2.0.

DRAIN: 1"IPS piped to open floor drain. No Solid Connection. Copper only.

C

G

D

9 [229]

12 [3

05]

1.12

[29]

WATER QUALITY STATEMENT

Total dissolved solids

pH FactorChlorineSilicaTotal alkalinity

Less than 1.5 PPMLess than 13 PPMLess than 20 PPM

7.0-8.5

Less than 60 PPM

D

24 [610]

SERVICE CONNECTIONS

5.25 [133]

3.50 [89]

1.75 [44]

3 [76]

C

G

SAFETY RELIEFVALVE

SAFETY RELIEFVALVE

2 [5

1]

25 [6

35]

16.25 [413]

LEGS

250 lbs. [113 kg] 13.245,00011.0-14.0"(280-356mm)6.0-14.0"(150-356mm)

GAS SUPPLY

* Use on non-combustible floors only.

convenient and adjacent to appliance.


Top Related