3-3/4/2.50 (11kV)
3-3/4/2.50 (11kV)4-6/1/3.75 (LV)
3-3/4/2.50 (11kV)2-6/1/3.75 (LV)
P766547
P759722P766905
P766514
U767014
P766513
P766512
U767017
P766535
P766534
P766533
P766519
P766511
P766510
U767022
P766509
P766499
P766486
P766516P90652
P87604
P1285106
SP16310
16LV
16s/l
16LV
16s/l
16s/l
16s/l
16LV
16LV
16LV
16s/l
16s/l
16s/l
16LV
16LV
16LV
16s/l
16s/l
16s/l
16LV
LOR
P3
V3
LORP3
V3
2xS250
2xS250
S250
S250
S250
S250
S250
S250
1.8m
1.0m
2xS250
2xS250
S250
69
138
PPPP
4m
5m
F40
70 141
16s/l
N6
16s/l
N6
16s/l
N6
1mN6
N6 5m
10m7m
D16s/l
N5
24011kV 16s/l
240LV
16s/l
D
9m
240
11kV
240L
V
N4
19m
L24011kV
240LV
N
24011kV
240LV
N
24011kV
240LV
N
24011kV
240LV
N
24011kV
240LV
NZ
240LV
4s/l
24011kV240LV
N
24011kV240LV
N240
11kV240LV
N
17m
24011kV4s/l
240LV
Z
O4s/l
L 4s/l
X
D
240LV
G 24011k
V240
LV240
11kV
240LV
G
24011kV
240LV
G
240LV
24011kV
G D
240LV
4s/l
O
D
240LV
D
240LV240LV
DD
240LV
L
P
240LV4s/l 6m
L
240L
V D
16s/l
DE
16s/l
44m
D
16s/l
LL
E
16s/l
D
44m
D
16s/l
P
240LV
4s/l
D
240LVLP1285332D
240LV
D16LV
O
4s/l
D
240LV
D16LV
D
240LV
D16LV
P
4s/l240LV
D
240LV
O4s/l
4s/l
O
D
16LV
D16LV
G
240L
V
240
11kV
G
240L
V
240
11kV
D
240LV
240L
V
L
D
L
240L
V
D16LV
240LV
J
4s/l
VJ
D
16LV
O
4s/l
D
16LV
DPROPOSEDSC1285283500kVA
REFERDETAIL 'B'
24011kV
240LV
GD
240LV
O
4s/l
S
240L
V
4s/l
240
11kV
240
11kV240L
V
G
240
11kV240L
V
G
D
D
240LV
D
240LV
240LV240LV4m
D
240LV
8m
240LV4s/l
P
D
240LV
D16
LV
O
4s/l
5m
O
4s/l
14m
D
240LV
D
16LV
240LV4s/l
PD
240LV
D
240LV
16LV
D
41m O
4s/l
1.5m
PROPOSEDSC1285282500kVAREFERDETAIL 'A'
STABILISE BANKTHE CIVIL CONTRACTOR IS TO COMPACT & STABILISE THE BANK TO PREVENT FUTURE WASHOUT,AFTER CONDUIT INSTALLATION
1.5m
D
16s/l
16.6m
16LV
D16LV
60
40
240LV
24011kV
G
16LV
D
P766545
D
16s/l
P766536
P766517S150
AA
BB
C
C
LOR
LOR
D
16LV
240
11kV
240L
V
16LV
LOR
LOR
16LV
COX
RD
YAWALPAH RD
SWAN
RD
MILLSTREAM PL
GREENMOUNT ST
GREE
NMOU
NT S
T
GAINSBOROUGH
UNDARRA ST
DR
411 412
416 414
402
413
359
376
344342
349
336
365
341339
333
388
348
373
386
419
408
407
409 410
401403404
405406
358
334335337338
340
343
354
353
356 357355352
351
350 363392
390
399
391
394
395
393
397
398
396
389
417418
387
415
362
360
361
375374
380
372371370369368
385
377
346347
345
379 378
384 383 382 381
400
367 366 364
LAMI
NGTO
N
PL
3
#154
8
57
9
10
#152
A
BC
CB
AA
BC
CB
AAB
CCB
11
12
13
14
4
15
6
2016
19
23 2425
26272829
PROPOSED LOCATION OF11kV STRAIGHT JOINT
3031
32
33
3534
37
AB
CC
BA
C
C
C
C
36
38
3940
41 42 43
45
AB C C B A
A
B
C
B
B
A
B
A B A B A
48
49
47
50
51
52
80 81
82
5557
58
60
62
61
83
84
BACCCCBAA
CA B A
BA B A B
77
7775
73726867
66
C
C
A
B
79
BA
AB
CC
C
C
AB
CC A
B
BA
BA
BC
3-3/4/2.50 (11kV)2-6/1/3.75 (LV)
69
64
63
44
46
65
53545659
1
2
LIVE LVCABLES
DANGER
120
17
18
8L
21P766550
22
LIVE LVCABLES
DANGER
UNDERGROUND CABLE CERTIFICATION
Certified (signature of checker): _______________________________
Serial No: ____________ Date Cables Checked: _____/_____/_____
Name of Person Who Conducted Checks: _______________________
Make: ____________________ Model: _______________________
Phone No. of checker: ______________________________________
All cables detailed on this drawing have been checked using thecable locator described below and are, according to measurementstaken, on the correct alignment and at correct depths below thefinished level, except as marked up. Alignments are subject to theaccuracy of survey pegs present at the time of measurement.
CONTRACTORS - NOTE
CONDUIT IN ALL TRENCHES WHERE A 125mm
ENERGEX NOW REQUIRES THE INSTALLATION OFA 100mm WHITE MEDIUM DUTY COMMUNICATIONS
ELECTRICITY CONDUIT IS INSTALLED.
The works detailed on this drawing shall be constructed in accordance with Robin Russell & Associates'General Specification for Installation of Electricity Reticulation and Street Lighting - Issue 'V'.
The installation of all electrical conduits shall be supervised by the holder of an electrical work licence.- Electrical Safety Act 2002.
Energex conduits and transformer site retaining walls shall be installed strictly in accordance withEnergex's specifications (see below). They will be inspected for compliance upon completion.
The civil contractor shall ensure that all conduits have been installed before constructing retainingwalls, paths, driveways & water services.
Care! Lighting of new or altered existing roads might not comply with specified standardsuntil new road lighting has been commissioned. The civil contractor shall ensure thatnecessary warning signs are installed and speed restrictions are applied if necessary.
Robin Russell & Associates gives no warranty regarding the presence or location of buried services,including newly-installed services. "As Constructed" locations may differ from what is drawn on thisworks plan. Contractors shall be responsible to identify and locate all buried services. Initialidentification can be obtained from:
Dial Before You Dig Service -Telephone 1100 Fax 1300 652 077On-line enquiries can be made at http://www.dialbeforeyoudig.com.au.
Having determined which services may be present, on-site locations should then be arranged withrelevant service authorities.Sewerage and water plans for the subdivision may be obtained on request from the Superintendent.
Telstra's contractor will lay Telstra's conduits and install Telstra's pits, in excavations provided.
ELECTRICAL CONTRACTOR
CIVIL CONTRACTOR
ON-SITE SERVICES CHECKS
TELSTRA INSTALLATION
Relevant specifications in Energex's Underground Distribution Construction Manualare found at - Section C1: Conduits
Section C2: Excavation Section C3: Transformer SitesThese sections of the manual can be downloaded from the following Energex web site:
http:/www.energex.com.au/about_energex/asp/technical_documents.aspCivil engineers who have registered for access to the following RRA website maydownload extracts from Energex's manual at:
http:/www.robrus.com.au
In residential subdivisions, Telstra's conduits shall be laid in shared electricity trenches where not morethan 2xP100s will be installed.In commercial subdivisions, or where more than 2xP100s will be installed, Telstra's conduits shall belaid in a separate trench.Contractors shall notify Telstra's contractor: one week before road crossing trenches will be open. two days before footpath trenches will be open.
Telstra's contractors are:North of Brisbane River: Service Stream CommunicationsIpswich & west: Service Stream CommunicationsSouth of Brisbane: Silcar Communications
The civil contractor shall install enveloping conduits under retaining walls behind pillars -two 100mm conduits into each lot (one for Electricity, one for Telstra),600mm deep behind the pillar, near ground level inside the lot.
ROAD LIGHTING CERTIFICATE
12
This design assumes maintenance factors of 0.7 for minor road lighting and 0.75 formajor road lighting. These maintenance factors are based on the following nominalmaintenance schedule, which might not necessarily be adopted by Energex.
This road lighting design is certified to comply generally with the nominated categories ofAS1158.1-1986, AS/NZS1158.1.1:2005 and/or AS/NZS1158.3.1:2005 for luminaires andlamps supplied under Energex contract 07075 (2010).
1. Lamps shall be replaced at 36-month intervals.2. At that time, luminaires shall be cleaned, inspected and maintained.3. Vegetation shall be kept clear of street lights.4. Inspection patrols and spot lamp replacement shall maintain service availability at
not less than 95%.5. Luminaires and lamps shall be replaced with exact equivalents.
Robin Russell RPEQ 1546
ROAD LIGHTING MAINTENANCE SCHEDULE
YAWALPAH RD(NORTH SIDE OF YAWALPAH RD RELEVANT TO SUBDIVISION) - CAT V3SWAN RD & GAINSBOROUGH DR - CAT P3GREENMOUNT ST, LAMINGTON PL, UNDARRA ST, MOONDARRA ST,MCDONNEL LA, MILLSTREAM PL & DAVENPORT PL - CAT P4PATHWAYS THROUGH PARK - CAT P4
SCALE 1:1000PLAN VIEW
1 : 1000 (A1 - NOT REDUCED)
-20m 0 20 40 60m
CONSULTANT CONTACTSELECTRICAL ENGINEERROBIN RUSSELL & ASSOCIATES PTY LTDDESIGNER
FIELD OFFICER
WILLIAM SCHARDT ph: 0419 778 552
BERNIE RUSSELL ph: 0413 598 560
TOTAL NUMBER OF LOTS
PROPERTY DESCRIPTION
SITE INFORMATION
134
PROPOSED LOTS 333-466 CANCELING LOT 4 on SP208815 & PART OF LOT 5 on SP44202
BIKE PATH CLEARANCES"Austroads Guide to Traffic Engineering Practice: Part 14 - Bicycles" specifies aminimum clearance of 0.5m between a bike path and any obstacle. In order toachieve specified road/path lighting within the specified verge, it has not beenpossible to satisfy that requirement.
ELECTRICAL CONTRACTOR TO ARRANGE THE FOLLOWING:POWDER COATING OF COLUMNS & OUTREACHES
Preferred Powder Coater:Electro Seal5-7 Platinum StreetCrestmead QLD 4132Contact Eric Newton
POWDER COAT COLUMNS & OUTREACHES AT STATIONS 19L, 26L, 29L, 32L, 38L, 41L1,45L, 49L, 50L, 80L 82L, 76L, 90L, 88L, 91L.For Powder Coating:Light abrasive blast, followed by powder coating AS2700 in COLOUR (N61) DULUX LUNARECLIPSE
LEGEND: ELECTRICAL
STATION NUMBER
RECOVER STREET LIGHT
PROPOSED U/G STREET LIGHT
FUTURE SERVICE PILLAR
EXISTING STREET LIGHT
PADMOUNT TRANSFORMER
CABLE MARKER POST
"ENERGEX ELECTRIC CABLE" MARKER PLATE
EXISTING SERVICE PILLAR
EARTH
HV POLE
HV + LV POLE
PROPOSED OVERHEAD ELECTRICITY MAINS
EXISTING OVERHEAD ELECTRICITY MAINS
PROPOSED POLE TRANSFORMER
METER BOX / LV SWITCHBOARD
LV or STREET LIGHT POLE
EXISTING UNDERGROUND CABLE
PROPOSED SERVICE PILLAR
PROPOSED UNDERGROUND CABLE
12
EXISTING CABLE
PROPOSED CABLE
LINK PILLAR
EXISTING RATE 3 STREETLIGHT CABLE
PROPOSED RATE 3 STREETLIGHT CABLE
EXISTING RATE 3 U/G STREET LIGHT
PROPOSED RATE 3 STREET LIGHT
FUTURE RATE 3 BOLLARD LIGHT
EXISTING CONSUMERS OVERHEAD CABLE
PROPOSED CONSUMERS OVERHEAD CABLE
EXISTING CONSUMERS UNDERGROUND CABLE
PROPOSED CONSUMERS UNDERGROUND CABLE
PROPOSED CONSUMERS SWITCHBOARD
C
32/40mm HD CONDUIT
80/100mm CONDUIT
125mm CONDUIT
100mm WHITE ENERGEX COMMS. CONDUIT
CI PILLAR
GAS
F6/11/2010 A PRELIMINARY ISSUE R.R.
19/4/2011 B ZERO LOT LINES, YAWALPAH RD R.R.
INT. SL'S, POLES AT STNS 160/ 161
TO CLEAR D'WAYS.
19/5/2011 C YAWALPAH RD MEDIAN WIDENED R.R.
TO RETAIN EXIST SL'S
30/5/2011 D COUNCIL APPROVED R.R.
12/7/2011 E PILLAR STN 301 ADDED R.R.
16/8/2011 F R.R.
A130-01S0103674 7
GAINSBOROUGH GREEN STAGES 6.1 & 6.2YAWALPAH RD & SWAN RDPIMPAMA
MIRVAC PACIFIC LTD
W.Schardt
Venmark Pty Ltd
6/11/2010
SWP47.1
GOLD COAST
326 M7
REVDATE REVISION APP. DATE REV
Specialising in ElectricityReticulation and Street Lighting
Consulting Engineers - Electrical
APP.
BRISBANE:McDowall, QLD 405321 Nicholas Street,
Fax: (07) 3872 5566Tel: (07) 3872 5555
4 Wakefield Street
Fax: (07) 5442 2758
Woombye, QLD 4559
Tel: (07) 5442 1758
SUNSHINE COAST:
SCALE
UBD REF
COUNCIL REF
COUNCIL
SPECIFICATIONENERGEX
AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT AUTHORITY.THIS DOCUMENT IS COPYRIGHT AND THE PROPERTY OF ROBIN RUSSELL & ASSOCIATES PTY LTD
DESIGNED
DRAWN
SIGNED
DATE
CLIENT
DESCRIPTION LOCATION
Email: [email protected] Email: [email protected]
APPROVED BYMap Gridwww.robrus.com.au 12
ENERGEX PROJECT No.
DRAWING No.
OF
SHEET No.
ROBIN RUSSELLRPEQ 1546
REVISION
A.B.N. 78 010 589 661& ASSOCIATES PTY. LTD.
A1@ A1 SIZE C 11:1000
ELECTRICAL RETICULATION
SOURCE DOCUMENTSCREATOR DRAWING REV. NO.DWG. NO. DATE
KN Group Pty Ltd BASE DRAWING 10-102-72-73-74-WATER-RCW.dwg - 6/9/2010
KN Group Pty Ltd BASE DRAWING 10-102-72-73-74-WATER-POT.dwg - 6/9/2010
KN Group Pty Ltd LANDSCAPING & PATHS 10-102FORM base.dwg - 12/10/2010
CIVIL ENGINEERKN GROUP PTY LTD
GEOFF GREENHALGH ph: 3017 1900
SURVEYORLANDPARTNERS LTD
JOHN DAVIDSON ph: 3842 1000
TELSTRA CONTRACTORSILCAR COMMUNICATIONS
SCOTT SMITH ph: 0407 147 698
1x100MD COMMS
2x100LD UPVC
4x125LD UPVC
NON STANDARD
2x40HD UPVC1x100LD UPVC
1x100MD COMMS
1x100LD UPVC
6x125LD UPVC
1x100MD COMMS
1x100LD UPVC
4x125LD UPVC
CONDUIT
CONDUIT
CONDUIT
TRENCH SECTION 'N5'
NON STANDARDTRENCH SECTION 'P1'
NON STANDARDTRENCH SECTION 'N6'
NON STANDARDTRENCH SECTION 'N4'
JOINT USE GAS INSTALLATION
ON A SEPARATE ALIGNMENT. JOINT USE TRENCH
GAS IS TO BE RETICULATED THROUGHOUT THIS PROJECT IN BOTH A JOINT USE TRENCH ARRANGEMENT &
LOCATIONS ARE DETAILED ON THE DRAWING.THE SEPARATE GAS ALIGNMENT WILL BE 900-1200.
PILLARS ON ZERO LOT BOUNDARYProposed pillars are to be offset as indicated awayfrom the zero lot line boundary lots with the side ofthe pillar aligned with the boundary alignment -offset the pillar opposite potential driveway locations(min. 1.0m clearance from edge of driveway required).Proposed streetlights are to be offset 1.0m from zerolot RP lines away from potential driveway positions.
NOT TO SCALE
Lot NoElectricity phase
Potentialhouse
Drive
way
locati
on
RP line
Telstra pits shall not clashwith potential drivewaypositions indicated
The side of theElectricity pillar isto be aligned withboundary line
49B
location
Streetlightoffset 1.0m
Zero Lot RP lineindicated on sideof boundary withGrey line
Pillar 1.0m clearof driveway
BACK OFKERB
CHANNEL
LIP OFKERB &
BITUMEN
S/LIG
HT
INVERTOF KERB
NOTE 1:-
GOLD COAST CITY COUNCILSTREETLIGHT ALIGNMENT DETAIL
THE POLE ALIGNMENT SHALL ENSURE THAT 0.7m IS MAINTAINED BETWEEN THE INVERT OF KERB & THE FACE OF POLE.
0.7(NOTE 1)
CONDUITS IN CENTRE MEDIANBY ELECTRICAL CONTRACTORTHE ELECTRICAL CONTRACTOR TOINSTALL THE CONDUITS IN THE CENTREMEDIAN BESIDE THE EXISTING LIVE CABLESEXTRA DEPTH EXCAVATION MAY BE REQUIRED.
1.8m
1.0m
13m
3.0m
5m
1m
24011kV 16s/l
240LV
16s/l
D
9m
240
11kV
240L
V
N4
19m
L24011kV
240LV
N
24011kV
240LV
N
24011kV
240LV
N
24011kV
240LV
N
24011kV
240LV
NZ
240LV
4s/l
24011kV240LV
N
24011kV240LV
N240
11kV240LV
N
17m
24011kV4s/l
240LV
Z
O4s/l
L 4s/l
X
D
240LV
G 24011k
V240
LV
24011kV
240LV
G
24011kV
240LV
G
240LV
24011kV
G D
240LV
4s/l
O
D
240LV
D
240LV240LV
DD
240LVL
P
240LV4s/l 6m
L
240L
V D
16s/l
DE
16s/l
44m
D
16s/l
LL
E
16s/l
D
44m
D
16s/l
P
240LV
4s/l
D
240LVLP1285332D
240LV
D16LV
O
4s/l
D
240LV
D16LV
D
240LV
D16LV
P
4s/l240LV
D
240LV
O4s/l
4s/l
O
D
16LV
D16LV
G
240L
V
240
11kV
G
240L
V
240
11kV
D
240LV
240L
V
L
D
L
240L
VZ
240L
V4s
/l
D16LV
240LV
J
240LV
4s/l
VJ
240LV
D
16LV
O
4s/l
D
16LV
D
240L
V
P 4s/l
240L
V
J
240LV
4s/l
V
D
16LV
J
240LV
J
240L
V
PROPOSEDSC1285283500kVA
REFERDETAIL 'B'
24011kV
240LV
GD
240LV
O
4s/lS
240L
V
4s/l
240
11kV
240
11kV240L
V
G
240
11kV240L
V
G
N
240L
V
D
6m
D 47m
D
16s/l
N
240L
V
E
16s/l
Z
4s/l
D
D
16s/l
47m
16m
1.5m
O
4s/l
N
1.5m
D
16s/l
D
16s/l
42m
1.5m
D
16s/lD
16s/l
40m
D
16s/l
1.5m
O
4s/l
4s/l240LV
P
D
240L
V
D
240L
V
E
240L
V24
0LV
D
16LV
D240LV
P
4s/l240L
V
D
240LV
O4s/lD
240LV
O4s/
l
240LV
D
P
4s/l240LV
D
240L
V
D
16LV
6m
P
4s/l240L
V
D
240L
V
D
16LV
D
240L
V
6.5m
P
240L
V4s
/l
D240LV
D
240LV
D
240LV
O
4s/l
D
240LV
D240LV
D
16s/l
D
16LV
O
4s/l
D
240LV
O4s/l
D
240LV
4s/l
P
4s/l
240LV
P
D
240LV
O
4s/l
D
240LV
7m
O
4s/l
D
240LV
D
240LV
D
16LV
Q
4s/l240LV
240LV
D240LV
4s/l240LV
P
4s/l
240LV
P
O
4s/l
4m
D
240LV
8m
240LV4s/l
P
D
240LV
D16
LV
O
4s/l
5m
O
4s/l
14m
D
240LV
D
16LV
240LV4s/l
PD
240LV
D
240LV
16LV
D
41m O
4s/l
1.5m
PROPOSEDSC1285282500kVAREFERDETAIL 'A'
16s/l240LV
P
O
4s/l
D
240L
V
P 4s/l
240L
V
P 4s/l
240L
V
D
240L
V
D
240L
V
2m
O4s/l
O
16s/l
16s/l
O
O
4s/l
12m
O
16s/l
42m
4s/l
O
1.5m
1.5m
16.6m
AA
BB
C
C
LOR
SWAN
RD
MILLSTREAM PL
GREENMOUNT ST
GREE
NMOU
NT S
T
DAVE
NPOR
T PL
MOONDARRA ST
MILLSTREAM PL
GAINSBOROUGH
UNDA
RRA
ST
UNDARRA ST
MOON
DARR
A S
T
DR
MOONDARRA ST
411 412
416 414
402
413
359
376
420
444
452
446
344342
349
336
365
341339
333
388
348
373
386
419
408
407
409 410
401403404
405406
425
422
433
451439
445
454
450
912
358
447 449448
334335337338
340
343
354
353
356 357355352
351
350 363392
390
399
391
394
395
393
397
398
396
389
417418
387
415
362
360
361
375374
380
372371370369368
385
377
466
455
464
459
462
458
463
456
465
457
461
453
438
434
443441 440
442
435 436 437
421
428
430
431
432
429424
346347
345
460
426 427
423
379 378
384 383 382 381
400
367 366 364
LAMI
NGTO
N
PL
MCDONNEL LA
A
BC
CB
AA
BC
CB
AAB
CCB
19
23 2425
26272829
PROPOSED LOCATION OF11kV STRAIGHT JOINT
3031
32
33
3534
37
AB
CC
BA
C
C
C
C
36
38
3940
41 42 43
45
AB C C B A
A
B
C
B
B
A
B
A B A B A
48
49
47
50
51
52
80 81
82
5557
58
60
62
61
83
84
BACCCCBAA
CA B A
BA B A B
77
78
77
CCCC
74
7573
71C
72
70
6867
66
C
C
A
B
BB
AA
85
79
90
86
8887
CCCB
89
91
92
98
97
94
A
B
A
A
B
A96
BBAB
99
C
BA
CC
BA
AB
C
104
INSTALL GALVANISEDSTEEL BOLLARDS TOPROTECT PILLAR
BA
AB
CC
C
C
AB
CC A
B
BA
BA
BC
BA
CB
B
A
B
A
C
A
A
B
C
C
134
1.5m
8m
69
95
93
76
64
63
44
46
65
53545659
2
OFFSET ROADCROSSING TO CLEAR
SEWER CHAMBER
Q
D16LV
16LV240LV4SL
1.0m
D
16s/l
41
39
39
1.5m
15m20m
29m
SCALE 1:1000PLAN VIEW
1 : 1000 (A1 - NOT REDUCED)
-20m 0 20 40 60m
CONSULTANT CONTACTSELECTRICAL ENGINEERROBIN RUSSELL & ASSOCIATES PTY LTDDESIGNER
FIELD OFFICER
WILLIAM SCHARDT ph: 0419 778 552
BERNIE RUSSELL ph: 0413 598 560
F6/11/2010 A PRELIMINARY ISSUE R.R.
19/4/2011 B ZERO LOT LINES, YAWALPAH RD R.R.
INT. SL'S, POLES AT STNS 160/ 161
TO CLEAR D'WAYS.
19/5/2011 C YAWALPAH RD MEDIAN WIDENED R.R.
TO RETAIN EXIST SL'S
30/5/2011 D COUNCIL APPROVED R.R.
12/7/2011 E PILLAR STN 301 ADDED R.R.
16/8/2011 F R.R.
A130-02S0103674 7
GAINSBOROUGH GREEN STAGES 6.1 & 6.2YAWALPAH RD & SWAN RDPIMPAMA
MIRVAC PACIFIC LTD
W.Schardt
Venmark Pty Ltd
6/11/2010
SWP47.1
GOLD COAST
326 M7
REVDATE REVISION APP. DATE REV
Specialising in ElectricityReticulation and Street Lighting
Consulting Engineers - Electrical
APP.
BRISBANE:McDowall, QLD 405321 Nicholas Street,
Fax: (07) 3872 5566Tel: (07) 3872 5555
4 Wakefield Street
Fax: (07) 5442 2758
Woombye, QLD 4559
Tel: (07) 5442 1758
SUNSHINE COAST:
SCALE
UBD REF
COUNCIL REF
COUNCIL
SPECIFICATIONENERGEX
AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT AUTHORITY.THIS DOCUMENT IS COPYRIGHT AND THE PROPERTY OF ROBIN RUSSELL & ASSOCIATES PTY LTD
DESIGNED
DRAWN
SIGNED
DATE
CLIENT
DESCRIPTION LOCATION
Email: [email protected] Email: [email protected]
APPROVED BYMap Gridwww.robrus.com.au 12
ENERGEX PROJECT No.
DRAWING No.
OF
SHEET No.
ROBIN RUSSELLRPEQ 1546
REVISION
A.B.N. 78 010 589 661& ASSOCIATES PTY. LTD.
A1@ A1 SIZE C 21:1000
ELECTRICAL RETICULATION
CIVIL ENGINEERKN GROUP PTY LTD
GEOFF GREENHALGH ph: 3017 1900
SURVEYORLANDPARTNERS LTD
JOHN DAVIDSON ph: 3842 1000
TELSTRA CONTRACTORSILCAR COMMUNICATIONS
SCOTT SMITH ph: 0407 147 698
SAG ( m )
25°CMAINS BOX
CHANGE POA
FUSE SIZE
PHSERVICE FITTING
CODE OR IIN
YAWALPAH RD 1 #154 4B25 4B25 1 45
1 #152 2B25 2B25 1 45
161 #154 4B25 1 47 47 3.03 51 N N 80 ABC N4B25WAN80
160 #152 2B25 1 48 48 2.48 52 N N 80 C N2B25WAN80
LV SERVICE SCHEDULE
LOCATION T’FER REC ERECTSTN No.
HOUSE No.
EXISTNo. OF SPANS
TOTAL CONDUCTOR LENGTH ( m )
FITTINGSDIST (m)
SAG SPAN
REMARKS
FROM TO FROM TO 150 300
YAWALPAH RD 4 150 11KV 3x3/4/2.50 1 70 220 110 70 4 150 0.54 0.70 SAG TO EXISTING TENSION
150 160 11KV 3x3/4/2.50 3x3/4/2.50 1 40 130 110 40 150 160 0.18 0.26 SAG TO EXISTING TENSION
160 3 11KV 3x3/4/2.50 3 169 530 110 50 160 161 0.40 0.56 SAG TO EXISTING TENSION
4 161 LV 4x6/1/3.75 3 170 710 110 50 160 161 0.40 0.62 SAG TO EXISTING TENSION
161 3 LV 4x6/1/3.75 2 109 340 110 59 2 3 0.53 0.77 SAG TO EXISTING TENSION
Notes: 19301. OVERHEAD CABLES TO BE SUPPLIED BY THE ELECTRICAL CONTRACTOR
TENSION TABLE
No. OF SPANS
OVERHEAD CONDUCTOR SCHEDULELOCATION
STATIONSVOLTS TRANSFER DISTANCERECOVER COMMENT
SAG (m)M.E.S.ERECT
SAG SPANCABLE TOTAL
DEGNO WIND
kNWIND
kNEXIST REC ERECT SINK FOOT STAYING ALIGN EXIST REC ERECT KBS EARTH
YAWALPAH RD 150 P1285281 274 6.37 11.35 P14/12 2.20 MDCF EXIST 11SC/S 150* MEN
TRA x 3
GSW37/SAS25 200
@ 11.5m & 80 BAR
FUT 11Kv UG TERM 1200
NAEF 2.95 LVP/NBAT 1800
160 P1298621 94 6.37 10.32 P14/12 2.20 MDCF EXIST 11SC/S 150* CGEC
TRA x 3
GSW37/SAS25 200 MEN
@ 11.5m & 80 BAR
NAEF 2.95 11PTTRIPXW 1200
P18.5/8 NAEF 2.95 11BRAL/240XL
NAEF 2.95 LVP/NBAT 1800
NAEF 2.95 LVT4C240/HV 150
NAEF 2.95 LVBR240/AOH
IS95 x 3 MAKE LV OPEN POINT
1 P87604 P12.5/8 P12.5/8 MDCF 11TD 11TD
NAEF 2.95 LVS LVS
IS95 IS95
S08277 x 4 6/1/3.75 COMP SLEEVES
BANANA x 70 6/1/3.75 CABLE
161 P1298622 271 4.28 7.85 P14/12 2.20 MDCF EXIST 11TD/NRAT 150* CGEC
NAEF 2.95 LVS/NRAT 2000 MEN 3ø/1ø SHACKLE
NAEF 2.95 IS95 x 1 LV OPEN POINT
BR95 x 1
NAEF 2.95
NAEF 2.95
2 P1285197 7 0 1.42 P14/8 2.40 NAEF EXIST 11TD/NRAT 150*
NAEF 2.95 LVP/NBAT 2000
OVERHEAD WORK SCHEDULELOCATION
STN No.
SITE I.D. (POLE No.)
REMARKSPOLES CONSTRUCTION
F6/11/2010 A PRELIMINARY ISSUE R.R.
19/4/2011 B ZERO LOT LINES, YAWALPAH RD R.R.
INT. SL'S, POLES AT STNS 160/ 161
TO CLEAR D'WAYS.
19/5/2011 C YAWALPAH RD MEDIAN WIDENED R.R.
TO RETAIN EXIST SL'S
30/5/2011 D COUNCIL APPROVED R.R.
12/7/2011 E PILLAR STN 301 ADDED R.R.
16/8/2011 F R.R.
A130-03S0103674 7
GAINSBOROUGH GREEN STAGES 6.1 & 6.2YAWALPAH RD & SWAN RDPIMPAMA
MIRVAC PACIFIC LTD
W.Schardt
Venmark Pty Ltd
6/11/2010
SWP47.1
GOLD COAST
326 M7
REVDATE REVISION APP. DATE REV
Specialising in ElectricityReticulation and Street Lighting
Consulting Engineers - Electrical
APP.
BRISBANE:McDowall, QLD 405321 Nicholas Street,
Fax: (07) 3872 5566Tel: (07) 3872 5555
4 Wakefield Street
Fax: (07) 5442 2758
Woombye, QLD 4559
Tel: (07) 5442 1758
SUNSHINE COAST:
SCALE
UBD REF
COUNCIL REF
COUNCIL
SPECIFICATIONENERGEX
AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT AUTHORITY.THIS DOCUMENT IS COPYRIGHT AND THE PROPERTY OF ROBIN RUSSELL & ASSOCIATES PTY LTD
DESIGNED
DRAWN
SIGNED
DATE
CLIENT
DESCRIPTION LOCATION
Email: [email protected] Email: [email protected]
APPROVED BYMap Gridwww.robrus.com.au 12
ENERGEX PROJECT No.
DRAWING No.
OF
SHEET No.
ROBIN RUSSELLRPEQ 1546
REVISION
A.B.N. 78 010 589 661& ASSOCIATES PTY. LTD.
A1@ A1 SIZE C 31:1000
ELECTRICAL RETICULATION
TFMR IS
315A
315A
CCT1 CCT2 CCT3 CCT4
240m
m
TRAN
SFOR
MER
240m
m
315A
240m
m
315A
LV SWITCHBOARDPROPOSED SC1285283 (68)
LV HV
1000
2000
PLIN
TH
1350
5000
300
11151870 PLINTH
11154800
EARTH GRID
Transformer site to be constructed by the Electrical Contractor, for new square series.For all construction details refer to Energex Underground Distribution Construction Manual - Section 4 .The Electrical Contractor shall arrange for a soil compaction test to be carried out on the transformer site andprovide Robin Russell and Associates with a written report of the results. If the result is: greater than 50 kPa then a concrete base slab shall be supplied and installed by the Electrical Contractor. less than 50 kPa then the Electrical Contractor shall provide a pier foundation in line with the Energex
Underground Construction Manual .The Civil Engineer and Civil Contractor shall ensure the site is level & prepared with retaining walls (if required) &safety fence (if required) in line with the requirements of the Energex Underground Distribution Construction Manual .
DETAIL 'B'SCALE 1:50 (AT A1 SIZE)
G
24011kV
240LV
D
240LV
MILLSTREAM PL
240L
V
240L
V
J
J
NOTE:THIS PMT IS TO BE LOCATED IN A LARGE AREA OF VACANT ROAD RESERVE: SURVEY IS TO PEG THE PMT SITE FORTHE ELECTRICAL CONTRACTOR
LAMI
NGTO
N P
L
PROPOSED SC.1285283 (68)
LOT 385
TFMR IS
315A
315A
CCT1 CCT2 CCT3 CCT4
240m
m
TRAN
SFOR
MER
240m
m
315A
315A
LV SWITCHBOARDPROPOSED SC1285282 (33)
LVHV
Transformer site to be constructed by the Electrical Contractor, for new square series.For all construction details refer to Energex Underground Distribution Construction Manual - Section 4 .The Electrical Contractor shall arrange for a soil compaction test to be carried out on the transformer site andprovide Robin Russell and Associates with a written report of the results. If the result is: greater than 50 kPa then a concrete base slab shall be supplied and installed by the Electrical Contractor. less than 50 kPa then the Electrical Contractor shall provide a pier foundation in line with the Energex
Underground Construction Manual .The Civil Engineer and Civil Contractor shall ensure the site is level & prepared with retaining walls (if required) &safety fence (if required) in line with the requirements of the Energex Underground Distribution Construction Manual .
1000
2000
PLIN
TH
1350
5000
300
11151870 PLINTH
11154800
EARTH GRID
DETAIL 'A'SCALE 1:50 (AT A1 SIZE)
4.47m
LOT 349
PARK
X
4s/lG 240
11kV
240LV
24011kV
4s/l240LV
Z
GAINSBOROUGH DRNOTE:THIS PMT IS TO BE LOCATED IN A LARGE AREA OF VACANT ROAD RESERVE: SURVEY IS TO PEG THE PMT SITE FORTHE ELECTRICAL CONTRACTOR
PROPOSED SC.1285282 (33)
PROPOSED COMMISSIONING PLANTentative only; subject to amendment by ENERGEX outage coordinator.
Live Line Works
Live live to erect poles at Stn 2 & Stn 150
Switching:
SHEET 1Live Line HV & LV Switching x 1Description of switching:Live Line to erect flying shackles at Stn 3 & Stn 4.Electrical contractor to complete works at stations 160, 1 & 161.
SHEET 1Live Line & LV Switching x 1Description of switching:
Live Line to bridge in & commission 11kV cable at Stn 160.Contractor to bridge in & commission LV cable at Stn 160
Where interruptions to existing consumers are required, they shall be notifiedin line with ENERGEX policies.
SP163104x6/1/3.75
YAWALPAH RD
4x6/1/3.754x6/1/3.75
2x6/1/3.75
YAWALPAH RD
240L
V
SP4824
P1298621
240L
V
240LVGAINSBOROUGH DR
240LV
240LVPROPOSEDSC1285282500kVA
33
3736240LV
4046
SWAN
RD
GREE
NMOU
NT S
T
240L
V
61 GREENMOUNT ST
240LV
53
LP1285332
65LP1285344
240L
V
240L
V
LP1285310
78
87
240LV
74
240L
V
93
240LVUNDARRA ST
LAMI
NGTO
N LA
PROPOSEDSC1285283500kVA
68
129
240LV
117MILLSTREAM PL
MILLSTREAM PL240LV
240L
VDA
VENP
ORT P
L
MOON
DARR
A
ST
MOONDARRA ST240LV
240L
V
LP1285365
MOONDARRA STMcDONNEL LA
MOON
DARR
A
ST
240L
V24
0LV
98
EXISTING & PROPOSEDLV SCHEMATICSCALE 1:2500
4P1285106
COX
RD24
0LV
240L
V
EXISTINGSC1285094315kVA
1604x6/1/3.75
LP1285074P1298622
LINKSOPEN
LINKSOPEN
67
IS32SF31100x40LOCATION
LABEL
ISOLATOR
FRONT
INSIDE
CABLE
SIDE
LABEL INFORMATION
BW
BW
150x50
150x50
10
10
BW
WB
150x40 20
15
LABELCOLOUR
LABELSIZE
LETTERSIZE
IS30
BOX
NEAR
DESTINATIONCABLE
CABLEDESTINATION
ISOLATOR
FEEDERIDENTIFICATION
IDENTIFICATION
LABELDESCRIPTION
TO LAMINGTON PLSC1285283 IS33
TOTRANSFORMER
TO YAWALPAH RDP1298621
TO LAMINGTON PLSC1285283 IS33
TOTRANSFORMER
TO YAWALPAH RDP1298621 WALL
AT GAINSBOROUGH DR (STN 33) SC128528211kV RMU LABELS
IS35SF34100x40LOCATION
LABEL
ISOLATOR
FRONT
INSIDE
CABLE
SIDE
LABEL INFORMATION
BW
BW
150x50
150x50
10
10
BW
WB
150x40 20
15
LABELCOLOUR
LABELSIZE
LETTERSIZE
IS33
BOX
NEAR
DESTINATIONCABLE
CABLEDESTINATION
ISOLATOR
FEEDERIDENTIFICATION
IDENTIFICATION
LABELDESCRIPTION
SPARETOTRANSFORMER
TO GAINSBOROUGHDR SC1285282 IS32
SPARETOTRANSFORMER
TO GAINSBOROUGHDR SC1285282 IS32 WALL
AT LAMINGTON PL (STN 68) SC128528311kV RMU LABELS
11kV CABLE - TO GAINSBOROUGH DR SC1285282 IS30
LABEL INFORMATIONCABLE
300x100TOWARDSSTN 5
SILVERKOLANABRONZE
6450-A4
LABELINGMANUAL
CIRCUITDIRECTION
LETTERCOLOUR
LABELSIZE COLOUR
LABEL LETTER
AS PER
SIZE
STN 5TOWARDS
CABLELV CABLE - TO GAINSBOROUGH DR SC1285282 & SERVICES
AT YAWALPAH RD (STN 160) P129862111kV / LV POLE LABEL
300x100 SILVERKOLANABRONZE
6450-A4
LABELINGMANUAL
AS PER
LABELSIZE
LETTERSIZECOLOUR
LABEL
80x35 5WB
TRANSFORMER ISOLATOR80x35 WB 6
AT GAINSBOROUGH DR (STN 33) SC1285282LABEL INFORMATION
LV SWITCHBOARD LABELSNo.
CIRCUIT
TRANSF.
1
ISOLATOR
80x35
80x35
5
5
WB
WB
3
2
4 WB 580x35
TO YAWALPAH RD P1298621 & SERVICES
TO LAMINGTON PL LP1285344 / GREENMOUNT ST LP1285332 &SERVICES
SPARE
SPARE
LABELSIZE
LETTERSIZECOLOUR
LABEL
80x35 5WB
TRANSFORMER ISOLATOR80x35 WB 6
AT LAMINGTON PL (STN 68) SC1285283LABEL INFORMATION
LV SWITCHBOARD LABELSNo.
CIRCUIT
TRANSF.
1
ISOLATOR
80x35
80x35
5
5
WB
WB
3
2
4 WB 580x35
TO MOONDARRA ST LP1285365 / SWAN RD LP1285310 &SERVICES
TO MOONDARRA ST LP1285365 & SERVICES
TO LAMINGTON PL LP1285344 / MILLSTREAM PL / DAVENPORTPL & SERVICES
SPARETO LAMINGTON PL LP1285344 / GAINSBOROUGH DR SC1285282 & SERVICES
AT GREENMOUNT ST (STN 53) LP1285332
SIZECOLOUR
5WB
DIRECTION
CABLE
SIZE
STN 52TOWARDS 150x50
5WBTOWARDSSTN 54
CABLE150x50
LABEL INFORMATIONLETTERCIRCUIT LABEL LABEL
TO SWAN RD LP1285310 / LAMINGTON PL SC1285283 / MOONDARRA STLP1285365 & SERVICES
LV LINK PILLAR LABELS
SPARE
AT SWAN RD (STN 87) LP1285310
SIZECOLOUR
5WB
DIRECTION
CABLE
SIZE
STN 85TOWARDS 150x50
5WBTOWARDSSTN 92
CABLE150x50
LABEL INFORMATIONLETTERCIRCUIT LABEL LABEL
TO LAMINGTON PL SC1285283 / MOONDARRA ST LP1285365 / GREENMOUNTST LP1285332 & SERVICES
LV LINK PILLAR LABELS
TO GREENMOUNT ST LP1285332 / GAINSBOROUGH ST SC1285282 &SERVICES
AT LAMINGTON PL (STN 65) LP1285344
SIZECOLOUR
5WB
DIRECTION
CABLE
SIZE
STN 67TOWARDS 150x50
5WBTOWARDSSTN 61
CABLE150x50
LABEL INFORMATIONLETTERCIRCUIT LABEL LABEL
TO LAMINGTON PL SC1285283 / MILLSTREAM PL / DAVENPORT PL &SERVICES
LV LINK PILLAR LABELS
TO LAMINGTON PL SC1285283 & SERVICES
AT MOONDARRA ST (STN 151) LP1285365
SIZECOLOUR
5WB
DIRECTION
CABLE
SIZE
STN 96TOWARDS 150x50
5WBTOWARDSSTN _
CABLE150x50
LABEL INFORMATIONLETTERCIRCUIT LABEL LABEL
TO SWAN RD LP1285310 / GREENMOUNT ST LP1285332 / LAMINGTON PLSC1285283 & SERVICES
LV LINK PILLAR LABELS
EXISTING & PROPOSED11kV SCHEMATIC
11kV FEEDER CMA9ASCALE 1:5000
TO SP17101SP5047SP766300X2073273
P929003x3/4/2.50
SP16310
PROPOSEDSC1285283500kVA
IS33IS35SF34
68
GREE
NMOU
NT S
TLA
MING
TON
PL
240 1
1kV
GAINSBOROUGH DR240 11kV
YAWALPAH RD
IS30PROPOSEDSC1285282500kVA
IS32SF31
33
SWAN
R
D
240 1
1kV
240 1
1kV
4P1285106
IS31SF32
IS33
EXISTINGSC1285094315kVA
COX
RD
TOSP16301SP252794SP13908SP5550
P87604
LIVE LINE TOERECT POLESPRIOR TOSHEET 1
23
3x3/4/2.50 P90652 X761668SP4824
LIVE LINE TO ERECTFLYING SHACKLESAT STN.3 & STN.4(SHEET 1)
BRIDGE IN & COMMISSION11kV & LV U/GCABLES (SHEET 2)
EXISTING & PROPOSEDSTREETLIGHT SCHEMATIC
SCALE 1:2500
88L
79
10
11
12
13
14
18
1617
1916s/l
16s/l16s/l 16s/l 16s/l
16s/l
16s/l
YAWALPAH ROAD
SWAN
ROA
D
REP.16LV16LV
16LV
REP.16LV
16LV
16LV
REP.16LV
16LV
16s/l
16LV
16LV
16LV
16LV
16s/l16s/l
16LV16LV
P7665472xS250CØ
16LV
P766516
S250AØ
S250AØP766905
GAW
THER
N R
D16
s/l16
s/l16
s/l
P766514S250BØ
170P7665452xS250
AØ
P7665362xS250
P766550S250(RECOVER)
16s/l
P766513S250
BØ P766512S250
P7665352xS250
P7665342xS250
AØ
CØP7665332xS250
REPLACEP7665192xS250
CØ
P766517S150
AØAØ
P766510S250
16s/l
16s/l
16s/l
P766511S250 BØ
COX
ROAD
P7665092xS250
AØ
16LV
SP16310
P7664992xS250
BØ
P7664862xS250
CØ
16LVP766489S250BØ
P766487S250
BØ
P766488S250
AØCØ
P766485S250
S/L PHASING SHOWNON SCHEMATIC
167
CØ
169
166
F6/11/2010 A PRELIMINARY ISSUE R.R.
19/4/2011 B ZERO LOT LINES, YAWALPAH RD R.R.
INT. SL'S, POLES AT STNS 160/ 161
TO CLEAR D'WAYS.
19/5/2011 C YAWALPAH RD MEDIAN WIDENED R.R.
TO RETAIN EXIST SL'S
30/5/2011 D COUNCIL APPROVED R.R.
12/7/2011 E PILLAR STN 301 ADDED R.R.
16/8/2011 F R.R.
A130-04S0103674 7
GAINSBOROUGH GREEN STAGES 6.1 & 6.2YAWALPAH RD & SWAN RDPIMPAMA
MIRVAC PACIFIC LTD
W.Schardt
Venmark Pty Ltd
6/11/2010
SWP47.1
GOLD COAST
326 M7
REVDATE REVISION APP. DATE REV
Specialising in ElectricityReticulation and Street Lighting
Consulting Engineers - Electrical
APP.
BRISBANE:McDowall, QLD 405321 Nicholas Street,
Fax: (07) 3872 5566Tel: (07) 3872 5555
4 Wakefield Street
Fax: (07) 5442 2758
Woombye, QLD 4559
Tel: (07) 5442 1758
SUNSHINE COAST:
SCALE
UBD REF
COUNCIL REF
COUNCIL
SPECIFICATIONENERGEX
AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT AUTHORITY.THIS DOCUMENT IS COPYRIGHT AND THE PROPERTY OF ROBIN RUSSELL & ASSOCIATES PTY LTD
DESIGNED
DRAWN
SIGNED
DATE
CLIENT
DESCRIPTION LOCATION
Email: [email protected] Email: [email protected]
APPROVED BYMap Gridwww.robrus.com.au 12
ENERGEX PROJECT No.
DRAWING No.
OF
SHEET No.
ROBIN RUSSELLRPEQ 1546
REVISION
A.B.N. 78 010 589 661& ASSOCIATES PTY. LTD.
A1@ A1 SIZE C 41:1000
ELECTRICAL RETICULATION
40mm DIALOCATIONCONDUIT BENDING RADIUS
horizontal bend
pillar - main cable
100mm DIA 125mm DIA
pillar - x-road cable
pillar - street light cable
street light
600 1830 1830
pole termination
transformer
- 1200 -
- 450 -
600 - -
300 - -
300 1200 1830
no bends required
JOINT USE GAS INSTALLATION
ON A SEPARATE ALIGNMENT. JOINT USE TRENCH
GAS IS TO BE RETICULATED THROUGHOUT THIS PROJECT IN BOTH A JOINT USE TRENCH ARRANGEMENT &
LOCATIONS ARE DETAILED ON THE DRAWING.THE SEPARATE GAS ALIGNMENT WILL BE 900-1200.
40mm HD No 100mm LD No 125mm LD NoENERGEX
100mm Comms MD
YAWALPAH RD 5 6 70 6 70 70
5 15 258 6 258 258
SWAN RD 5 92 400 2 400 400
728728TOTAL 2768
ENERGEX FUNDED CONDUITS TOTAL
LOCATIONSTATIONS FROM − TO
CONDUIT LENGTH (m)TRENCH
(M)REMARKS
40mm HD
No100mm
LDNo
125mm LD
NoENERGEX
100mm Comms MD
YAWALPAH RD 160 5 50 1 50 1 50 50 50 G 156 2CIVIL TO COMPACT & STABALISE BANK WITHIN CONDUIT TRENCH
50
5 6 70 1 70 6 70 70 70 N6 576 2 CONDUITS FUNDED BY ENERGEX 70
9 150 50 1 50 50 50 F 104 2CIVIL TO COMPACT & STABALISE BANK WITHIN CONDUIT TRENCH
50
SWAN RD 21 22 22 1 RECOVER EXISTING CONDUITS
16 17 15 1 15 15 D 17 2 15
17 20 19 1 19 19 D 21 2 19
18 19 49 1 49 49 D 51 2 49
23 24 40 1 40 2 40 40 40 L 168 2 40
23 45 37 1 37 2 37 37 37 L 156 2 37
46 47 15 2 15 15 E 34 2 15
47 48 15 1 15 15 D 17 2 15
49 50 44 1 44 44 D 46 2 44
51 52 28 1 28 2 28 28 28 L 120 2 28
52 80 16 2 16 16 E 36 2 16
80 81 15 1 15 15 D 17 2 15
80 82 34 1 34 34 D 36 2 34
83 84 30 1 30 30 D 32 2 30
83 77 32 1 32 2 32 32 32 L 136 2 32
78 79 30 1 30 30 D 32 2 30
85 86 30 1 30 30 D 32 2 30
87 88 16 2 16 16 E 36 2 16
88 89 15 1 15 15 D 17 2 15
90 91 95 1 95 95 D 97 2 95
GAINSBOROUGH DR 33 34 15 1 15 1 15 2 15 15 15 X 85 2 15
33 36 40 1 40 1 40 40 40 G 126 2 40
40 41 30 1 30 30 D 32 2 30
GREENMOUNT ST 54 55 22 1 22 22 D 24 2 22
56 57 23 1 23 23 D 25 2 23
56 58 22 1 22 22 D 24 2 22
60 61 26 1 26 26 D 28 2 26
62 63 23 1 23 23 D 25 2 23
62 64 18 1 18 18 D 20 2 18
LAMINGTON PL 66 67L2 12 1 12 12 O 14 2 12
67 68 15 1 15 1 15 15 15 G 51 2 15
UNDARRA ST 69 70 28 2 28 1 28 28 28 J 120 2 28
71 72 28 1 28 28 D 30 2 28
71 73 20 1 20 20 D 22 2 20
71 74 28 2 28 1 28 28 28 J 120 2 28
74 75 22 1 22 22 D 24 2 22
76 77 23 1 23 23 D 25 2 23
146 103 17 1 17 17 D 19 2 17
101 102 17 1 17 17 D 19 2 17
99 300 6 1 6 2 6 6 Q 24 2 6
300 100 15 1 15 15 D 17 2 15
MOONDARRA ST 93 94 16 1 16 16 D 18 2 16
95 96 21 1 21 21 D 23 2 21
300 301 18 1 18 18 D 20 2 18
151 151L 16 1 16 16 O 18 2 16
110 110L 16 1 16 16 O 18 2 16
111 112 23 1 23 23 D 25 2 23
107 108 22 1 22 22 D 24 2 22
107 106L2 12 1 12 12 O 14 2 12
DRIVEWAY 105 105L 14 1 14 14 O 16 2 14
MILLSTREAM PL 68 104 22 1 22 22 D 24 2 22
115 115L 14 1 14 14 O 16 2 14
117 118 17 1 17 17 D 19 2 17
119 130 21 1 21 21 D 23 2 21
120 119L2 15 1 15 15 O 17 2 15
122 123 20 1 20 20 D 22 2 20
123 124 10 1 10 10 O 12 2 10
125 126 18 1 18 18 D 20 2 18
127 128 28 1 28 28 D 30 2 28
132 133L1 14 1 14 14 O 16 2 14
134 134L 23 1 23 23 O 25 2 23
PARK 135 136 10 1 10 10 O 12 2 10
147 138 10 1 10 10 O 12 2 10
112 139 10 1 10 10 O 12 2 10
139 140 10 1 10 10 D 12 2 10
144 144L 5 1 5 5 O 7 2 5
148 145L2 5 1 5 5 O 7 2 5
NOTES
URD CONDUIT SCHEDULE - ROADWAYS - BY CIVIL CONTRACTOR
NOTE: ENERGEX REQUIRES THE INSTALLATION OF A 100mm WHITE, MEDIUM DUTY, COMMUNICATIONS CONDUIT IN ALL TRENCHES WHERE A 125mm
KERB MARK
’E’REMARKSLOCATION
STATIONS FROM − TO
TRENCH BY CIVIL
1605
CONDUIT LENGTH (m)DRAW ROPE
(m)
2. ROAD CROSSING CONDUITS SHALL HAVE A MINIMUM COVER OF 800mm AT ALL PLACES UNDER THE ROAD, EXCEPT UNDER STATE−CONTROLLED "MAIN" ROADS,
3. CONDUITS SHALL EXTEND TO WITHIN 300mm OF PROPERTY ALIGNMENT; PVC PROTECTIVE COVER STRIPS SHALL BE LAID ABOVE ALL ROAD−CROSSING CONDUITS
EXCAV/ TAPE
WHERE CONDUITS SHALL HAVE A MINIMUM COVER OF 1250mm.
FOR THEIR FULL LENGTH.
TRENCH DETAIL
PVC CABLE PROTECTION
(m)
X−SECTION (m)
1. ROAD CROSSING CONDUITS SHALL BE INSTALLED STRICTLY IN ACCORDANCE WITH THE ENERGEX UNDERGROUND DISTRIBUTION CONSTRUCTION MANUAL V.5 SECT. C2.
433
ELECTRICITY CONDUIT IS INSTALLED. (REFER SCHEDULES FOR DETAILS OF WHERE THESE CONDUITS ARE REQUIRED)
4. REFER ENERGEX UDC MANUAL V.5 SECT. C2 FOR CROSS−SECTION DETAILS.
5. BRASS "E" MARKERS SHALL BE INSTALLED IN KERBS DIRECTLY ABOVE ELECTRICITY CONDUITS.
6. CAUTION: DO NOT CONSTRUCT RETAINING WALLS, CONCRETE PATHS OR WATER SERVICES UNTIL FOOTPATH CONDUITS HAVE BEEN INSTALLED.
7. GAS MAINS SHALL BE INSTALLED IN A JOINT USE ELECTRICITY TRENCH ON THIS PROJECT.
TOTAL 207 1500 935 3273 1381605 1605
LV
AT240XSH CT240XSH A4240XPV C416XPV C216PVPV C24PVPV
YAWALPAH RD / SWAN RD / GAINSBOROUGH DR
160 33 11kV * 410
GAINSBOROUGH DR / GREENMOUNT ST / LAMINGTON PL
33 68 11kV * 300
YAWALPAH RD / SWAN RD 160 23 LV * 131
YAWALPAH RD 16 13 SL * 178
163 164 LV * * * 49
166 167 LV * * * 59
169 170 LV * * * 54
GAINSBOROUGH DR 23 33 LV * 312
33 36 LV * 52
36 37 LV * 32
36 40 LV * 102
40 46 LV * 222
GREENMOUNT ST 40 52 LV * 264
62 63 LV * 26
62 64 LV * 23
56 58 LV * 25
56 57 LV * 25
54 55 LV * 25
SWAN RD 52 87 LV * 149
16 20 SL * 37
21 22 SL * * 39
18 19 SL * 50
46 47 SL * 18
49 50 SL * 46
52 82 SL * 52
87 88 SL * 18
90 91 SL * 97
LAMINGTON PL 61 68 LV * 110
UNDARRA ST 68 78 LV * 182
71 72 LV * 31
71 73 LV * 24
74 75 LV * 26
76 77 LV * 27
68 100 LV * 130
146 103 LV * 20
101 102 LV * 20
DRIVEWAY 146 108 LV * 108
MOONDARRA ST 74 93 LV * 34
93 94 LV * 20
93 98 LV * 96
93 151 LV * 93
151 112 LV * 168
112 113 LV * 37
99 301 LV * 28
PATH IN PARK OFF MOONDARRA ST
112 145 SL * 248
MILLSTREAM PL 68 129 LV * 356
117 118 LV * 21
122 123 LV * 24
125 126 LV * 25
127 128 LV * 32
MILLSTREAM PL / DAVENPORT PL
117 135 LV * 182
PATH IN PARK OFF DAVENPORT PL
135 138 SL * 60
ALL STREETS LV * 138 BRIDGING
SL * 1338
SUB−TOTAL 710 2723 759 804 1338
VARIANCE 5 % 36 137 38 41 67
TOTAL 746 2860 797 845 1405 00TRENCH 3638m
REMARKS11
AT PILLARS
STREETLIGHTS
NOTES:
1. THE CONTRACTOR SHALL MEASURE ACTUAL CABLE LENGTHS REQUIRED, AFTER INSTALLATION OF CONDUITS, THEN ORDER CABLE ACCORDINGLY.
UNDERGROUND CABLE SCHEDULELOCATION
STATIONS FROM − TO
VOLTS EX REC IN
CABLE SIZE / TYPE
F6/11/2010 A PRELIMINARY ISSUE R.R.
19/4/2011 B ZERO LOT LINES, YAWALPAH RD R.R.
INT. SL'S, POLES AT STNS 160/ 161
TO CLEAR D'WAYS.
19/5/2011 C YAWALPAH RD MEDIAN WIDENED R.R.
TO RETAIN EXIST SL'S
30/5/2011 D COUNCIL APPROVED R.R.
12/7/2011 E PILLAR STN 301 ADDED R.R.
16/8/2011 F R.R.
A130-05S0103674 7
GAINSBOROUGH GREEN STAGES 6.1 & 6.2YAWALPAH RD & SWAN RDPIMPAMA
MIRVAC PACIFIC LTD
W.Schardt
Venmark Pty Ltd
6/11/2010
SWP47.1
GOLD COAST
326 M7
REVDATE REVISION APP. DATE REV
Specialising in ElectricityReticulation and Street Lighting
Consulting Engineers - Electrical
APP.
BRISBANE:McDowall, QLD 405321 Nicholas Street,
Fax: (07) 3872 5566Tel: (07) 3872 5555
4 Wakefield Street
Fax: (07) 5442 2758
Woombye, QLD 4559
Tel: (07) 5442 1758
SUNSHINE COAST:
SCALE
UBD REF
COUNCIL REF
COUNCIL
SPECIFICATIONENERGEX
AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT AUTHORITY.THIS DOCUMENT IS COPYRIGHT AND THE PROPERTY OF ROBIN RUSSELL & ASSOCIATES PTY LTD
DESIGNED
DRAWN
SIGNED
DATE
CLIENT
DESCRIPTION LOCATION
Email: [email protected] Email: [email protected]
APPROVED BYMap Gridwww.robrus.com.au 12
ENERGEX PROJECT No.
DRAWING No.
OF
SHEET No.
ROBIN RUSSELLRPEQ 1546
REVISION
A.B.N. 78 010 589 661& ASSOCIATES PTY. LTD.
A1@ A1 SIZE C 51:1000
ELECTRICAL RETICULATION
40mm DIALOCATIONCONDUIT BENDING RADIUS
horizontal bend
pillar - main cable
100mm DIA 125mm DIA
pillar - x-road cable
pillar - street light cable
street light
600 1830 1830
pole termination
transformer
- 1200 -
- 450 -
600 - -
300 - -
300 1200 1830
no bends required
JOINT USE GAS INSTALLATION
ON A SEPARATE ALIGNMENT. JOINT USE TRENCH
GAS IS TO BE RETICULATED THROUGHOUT THIS PROJECT IN BOTH A JOINT USE TRENCH ARRANGEMENT &
LOCATIONS ARE DETAILED ON THE DRAWING.THE SEPARATE GAS ALIGNMENT WILL BE 900-1200.
40mm HD
No100mm
LDNo
125mm LD
NoENERGEX
100mm Comms MD
TRENCH DETAIL
PVC CABLE PROTECTION
(m)
X−SECTION (m)
URD CONDUIT SCHEDULE - FOOTPATHS - BY ELECTRICAL CONTRACTORCONDUIT LENGTH (m)
LOCATIONSTATIONS FROM − TO EXCAV/
TAPE TRENCH
DRAW ROPE
(m)
KERB MARK
’E’REMARKS
GAINSBOROUGH DR 33 SC1285282*
500kVA PADMOUNT HV FUSE LINK
TR1S21660
DSHVF5SLK 1 1
.*
240 mmsq AL 11KV CFC TERM HEAT SHRINK CAP
1CFC9524XLG S06614
2 2
. * 240mmsq LV TERMINATION LVPT4C240 2
. * 315A LV FUSE DSLVF31 2
.*
EARTH GRID − COMMON ADDITIONAL EARTH
DSSQPMEG DSPMTEGSA
1 1
. * UNICULVERT & BASE 1 CONTRACTOR SUPPLY
. * CONCRETE SURROUND 1 CONTRACTOR SUPPLY
149 U1285284*
11KV S/JOINT 240ATR / 240ATR HEATSHRINK CAP
CJ111ST24/24X
S06614 1 2
LAMINGTON PL 68 SC1285283*
500kVA PADMOUNT HV FUSE LINK
TR1S21660
DSHVF5SLK 1 1
.*
240 mmsq AL 11KV CFC TERM HEAT SHRINK CAP
1CFC9524XLG S06614
1 1
. * 240mmsq LV TERMINATION LVPT4C240 3
. * 315A LV FUSE DSLVF31 3
.*
EARTH GRID − COMMON ADDITIONAL EARTH
DSSQPMEG DSPMTEGSA
1 1
. * UNICULVERT & BASE 1 CONTRACTOR SUPPLY
. * CONCRETE SURROUND 1 CONTRACTOR SUPPLY
EQUIPMENT SCHEDULE - TFMR & JOINTLOCATION
STN NO.
SITE I.D. EX RECCOMP
I.D.CU/SC QTYIN SIZE & DESCRIPTION REMARKS
PARK 34 34L 23 1 23 O 25 23
123 124L2 51 1 51 O 53 51
135 138 57 1 57 O 59 57
138 138L2 50 1 50 O 52 50
139L1 139 28 1 28 O 30 28
139 139L2 22 1 22 O 24 22
112 140 17 1 17 D 19 17
139 145 220 1 220 D 222 220
145 148 41 1 41 O 43 41
588
NOTES
CONSTRUCTION MANUAL V.5.0 SECT. C2.
1. CONDUITS SHALL BE INSTALLED WITHIN A CORRIDOR 300−900mm FROM PROPERTY ALIGNMENT, IN ACCORDANCE WITH ENERGEX UNDERGROUND DISTRIBUTION
NOTE: ENERGEX NOW REQUIRES THE INSTALLATION OF A 100mm WHITE, MEDIUM DUTY, COMMUNICATIONS CONDUIT IN ALL TRENCHES WHERE A 125mm
2. FOOTPATH CONDUITS SHALL HAVE MINIMUM 700mm COVER. BACK FILL TRENCH WITH SAND TO A DEPTH OF 600mm FROM ANTICIPATED FINAL FOOTPATH LEVEL
3192
ALL STREETSAT PILLARS
& POLESPVC COVER STRIP AT PILLARS & S/L POLES
532 1
ELECTRICITY CONDUIT IS INSTALLED. (REFER SCHEDULES FOR DETAILS OF WHERE THESE CONDUITS ARE REQUIRED)
3665TOTAL 1288
532
755 31331178 8833 6
3. CONNECT EXISTING CONDUITS, INCLUDING ROAD CROSSING CONDUITS, TO NEW FOOTPATH CONDUITS
3335
4. GAS MAINS SHALL BE INSTALLED IN A JOINT USE ELECTRICITY TRENCH ON THIS PROJECT.
40mm HD
No100mm
LDNo
125mm LD
NoENERGEX
100mm Comms MD
YAWALPAH RD 5 15 258 1 258 6 258 258 N6 2080CONDUITS FUNDED BY
ENERGEX258
7 8 5 1 5 D 7 5
9 10 5 1 5 D 7 5
11 12 5 1 5 D 7 5
13 14 5 1 5 D 7 5
163 164 46 1 46 46 D 48 2CENTRE MEDIAN CONDUITS BY ELECTRICAL (RECOVER
EXISTING CONDUIT)46
166 167 55 1 55 55 D 57 2CENTRE MEDIAN CONDUITS BY ELECTRICAL (RECOVER
EXISTING CONDUIT)55
169 170 50 1 50 50 D 52 2CENTRE MEDIAN CONDUITS BY ELECTRICAL (RECOVER
EXISTING CONDUIT)50
SWAN RD 21 22 RECOVER EXIST CONDUITS
5 16 13 2 13 4 13 13 N5 1052x125 CONDUITS FUNDED BY
ENERGEX13
16 23 60 1 60 4 60 60 N4 3722x125 CONDUITS FUNDED BY
ENERGEX60
45 51 55 1 55 2 55 55 L 2282x125 CONDUITS FUNDED BY
ENERGEX55
52 83 42 1 42 2 42 42 L 1762x125 CONDUITS FUNDED BY
ENERGEX42
77 78 6 1 6 2 6 2 6 6 Z 482x125 CONDUITS FUNDED BY
ENERGEX6
78 87 50 2 50 2 50 50 N 2602x125 CONDUITS FUNDED BY
ENERGEX50
87 87L 36 1 32 2 32 2 32 36 Z 2082x125 CONDUITS FUNDED BY
ENERGEX36
87L 92 40 2 40 2 40 40 N 2102x125 CONDUITS FUNDED BY
ENERGEX40
GAINSBOROUGH DR 23 29L 146 2 146 2 146 146 N 740 146
29L 29 14 1 14 2 14 2 14 14 Z 96 14
29 32 88 2 88 2 88 88 N 450 88
32 33 17 1 17 2 17 2 17 17 Z 114 17
34 35 15 1 15 2 15 15 L 68 15
36 37 27 1 27 D 29 27
36 40 91 1 91 1 91 91 G 279 91
41 45L 121 1 121 D 123 121
45L 45 15 1 15 1 15 P 34 15
GREENMOUNT ST 40 65 98 1 98 1 98 98 G 300 98
41 41L2 12 1 4 12 O 14 12
64 64L2 22 1 4 22 O 24 22
60 59 28 1 28 D 30 28
59 59L 12 1 12 1 12 P 28 12
59L 52L 64 1 64 D 66 64
52L 52 14 1 14 1 14 P 32 14
LAMINGTON PL 65 66 36 1 36 1 36 36 G 114 36
66 67 14 1 14 1 14 1 14 14 S 64 14
UNDARRA ST 70 71L1 26 2 26 1 26 26 J 112 26
71L 71 21 1 21 2 21 1 21 21 V 115 21
73 73L 13 1 4 13 O 15 13
74 76 22 2 22 1 22 22 J 96 22
76 76L 24 1 24 2 24 1 24 24 V 130 24
76L 77 10 2 10 1 10 10 J 48 10
104 104L 8 1 8 1 8 P 20 8
104L 101L 44 1 44 D 46 44
101L 101 6 1 6 1 6 P 16 6
101 100 30 1 30 D 32 30
MOONDARRA ST 74 93L 18 1 18 D 20 18
93L 93 13 1 13 1 13 P 30 13
93 95 14 2 14 E 32 14
95 97 13 1 13 D 15 13
97 98L 43 1 43 D 45 43
98L 98 20 1 20 1 20 P 44 20
MOONDARRA ST 96 96L 28 1 28 1 28 P 60 28
96L 99 50 1 50 D 52 50
100 100L 12 1 12 1 12 P 28 12
100L 111 68 1 68 D 70 68
112 113 33 1 33 D 35 33
113 113L 14 1 4 14 O 16 14
DRIVEWAY 146 106 62 1 62 D 64 62
106 107 18 1 18 1 18 P 40 18
MILLSTREAM PL 67 117 112 1 112 D 114 112
117 119 16 1 16 2 16 Q 54 16
119 120 38 1 38 1 38 P 80 38
120 121 28 1 28 D 30 28
121 121L2 25 1 25 1 25 P 54 25
121L2 125 45 1 45 D 47 45
125 125L 17 1 17 1 17 P 38 17
125L 129 54 1 54 D 56 54
130 130L 18 1 18 1 18 p 40 18
DAVENPORT PL 130L 132 27 1 27 D 29 27
132 133L2 31 1 31 1 31 P 66 31
133L2 135 38 1 38 D 40 38
MOONDARRA ST / McDONNELL LA
TRENCH DETAIL
PVC CABLE PROTECTION
(m)
X−SECTION (m)
URD CONDUIT SCHEDULE - FOOTPATHS - BY ELECTRICAL CONTRACTORCONDUIT LENGTH (m)
LOCATIONSTATIONS FROM − TO EXCAV/
TAPE TRENCH
DRAW ROPE
(m)
KERB MARK
’E’REMARKS
F6/11/2010 A PRELIMINARY ISSUE R.R.
19/4/2011 B ZERO LOT LINES, YAWALPAH RD R.R.
INT. SL'S, POLES AT STNS 160/ 161
TO CLEAR D'WAYS.
19/5/2011 C YAWALPAH RD MEDIAN WIDENED R.R.
TO RETAIN EXIST SL'S
30/5/2011 D COUNCIL APPROVED R.R.
12/7/2011 E PILLAR STN 301 ADDED R.R.
16/8/2011 F R.R.
A130-06S0103674 7
GAINSBOROUGH GREEN STAGES 6.1 & 6.2YAWALPAH RD & SWAN RDPIMPAMA
MIRVAC PACIFIC LTD
W.Schardt
Venmark Pty Ltd
6/11/2010
SWP47.1
GOLD COAST
326 M7
REVDATE REVISION APP. DATE REV
Specialising in ElectricityReticulation and Street Lighting
Consulting Engineers - Electrical
APP.
BRISBANE:McDowall, QLD 405321 Nicholas Street,
Fax: (07) 3872 5566Tel: (07) 3872 5555
4 Wakefield Street
Fax: (07) 5442 2758
Woombye, QLD 4559
Tel: (07) 5442 1758
SUNSHINE COAST:
SCALE
UBD REF
COUNCIL REF
COUNCIL
SPECIFICATIONENERGEX
AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT AUTHORITY.THIS DOCUMENT IS COPYRIGHT AND THE PROPERTY OF ROBIN RUSSELL & ASSOCIATES PTY LTD
DESIGNED
DRAWN
SIGNED
DATE
CLIENT
DESCRIPTION LOCATION
Email: [email protected] Email: [email protected]
APPROVED BYMap Gridwww.robrus.com.au 12
ENERGEX PROJECT No.
DRAWING No.
OF
SHEET No.
ROBIN RUSSELLRPEQ 1546
REVISION
A.B.N. 78 010 589 661& ASSOCIATES PTY. LTD.
A1@ A1 SIZE C 61:1000
ELECTRICAL RETICULATION
EQUIPMENT SCHEDULE - SERVICE PILLARSLOCATION STN NO. SITE I.D. EX REC IN SIZE AND DESCRIPTION
COMP I.D.
REMARKSCU/SC QTY
YAWALPAH RD 7 U1285285 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
8 U1285286 * No.4 PIT, LID & J’BOX (FUSED) SLM15528SBM 1
9 U1285287 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
10 U1285288 * No.4 PIT, LID & J’BOX (FUSED) SLM15528SBM 1
11 U1285289 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
12 U1285290 * No.4 PIT, LID & J’BOX (FUSED) SLM15528SBM 1
13 U1285291 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
14 U1285292 * No.4 PIT, LID & J’BOX (FUSED) SLM15528SBM 1
163 U767021 * * * No.4 PIT, LID & 3PH J’BOX (FUSED) SLM17091SBM 1
164 U767020 * * * No.4 PIT, LID & 3PH J’BOX (FUSED) SLM17091SBM 1
166 U767018 * * * No.4 PIT, LID & 3PH J’BOX (FUSED) SLM17091SBM 1
167 U767017 * * * No.4 PIT, LID & 3PH J’BOX (FUSED) SLM17091SBM 1
169 U767015 * * * No.4 PIT, LID & 3PH J’BOX (FUSED) SLM17091SBM 1
170 U767014 * * * No.4 PIT, LID & 3PH J’BOX (FUSED) SLM17091SBM 1
SWANN RD 16 U1285293 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
17 U1285294 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
18 U1285295 * No.4 PIT, LID & J’BOX (FUSED) SLM15528SBM 1
19 U1285296 * No.4 PIT, LID & J’BOX (FUSED) SLM15528SBM 1
20 U1285297 * No.4 PIT, LID & J’BOX (FUSED) SLM15528SBM 1
21 U1285298 * * No.4 PIT, LID & J’BOX (FUSED) −1
45 U1285299 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
46 U1285300 * 1 WAY PILLAR, S/L & MEN Pl1LVSP2−6SL
1011−21 1
47 U1285301 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
49 U1285302 * No.4 PIT, LID & J’BOX (FUSED) SLM15528SBM 1
50 U1285303 * No.4 PIT, LID & J’BOX (FUSED) SLM15528SBM 1
52 U1285304 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
80 U1285305 * No.4 PIT, LID & J’BOX (FUSED) SLM15528SBM 1
82 U1285306 * No.4 PIT, LID & J’BOX (FUSED) SLM15528SBM 1
83 U1285307 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
78 U1285308 * 3 WAY PILLAR & S/L Pl1 LVSP9−6SL 1
85 U1285309 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
87 LP1285310 *2 WAY LINK PILLAR,S/L & MEN (L) LETTER
PI1LVSP14−6SL
1037−1 S17319
1 1 1
88 U1285311 * No.4 PIT, LID & J’BOX (FUSED) SLM15528SBM 1
90 U1287444 * No.4 PIT, LID & J’BOX (FUSED) SLM15528SBM 1
91 U1285312 * No.4 PIT, LID & J’BOX (FUSED) SLM15528SBM 1
GAINSBOROUGH ST 23 U1285313 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
25 U1285314 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
26 U1285315 * 2 WAY PILLAR, S/L & MEN Pl1LVSP4−6SL
1011−2 1 1
27 U1285316 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
28 U1285317 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
29 U1285318 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
30 U1285319 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
31 U1285320 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
32 U1285321 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
34 U1285322 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
36 U1285323 * 3 WAY PILLAR & S/L Pl1 LVSP9−6SL 1
37 U1285324 * 2 WAY PILLAR, S/L & MEN Pl1LVSP4−6SL
1011−2 1 1
38 U1285325 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
39 U1285326 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
40 U1285327 * 3 WAY PILLAR & S/L Pl1 LVSP9−6SL 1
41 U1285328 * 2 WAY PILLAR, S/L & MEN Pl1LVSP4−6SL
1011−2 1 1
42 U1285329 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
43 U1285330 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
44 U1285331 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
GREENMOUNT ST 53 LP1285332 *2 WAY LINK PILLAR,S/L & MEN (L) LETTER
PI1LVSP14−6SL
1037−1 S17319
1 1 1
54 U1285333 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
55 U1285334 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
56 U1285335 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
57 U1285336 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
58 U1285337 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
59 U1285338 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
60 U1285339 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
61 U1285340 * 3 WAY PILLAR & S/L Pl1 LVSP9−6SL 1
62 U1285341 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
63 U1285342 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
64 U1285343 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
LAMINGTON ST 65 LP1285344 *2 WAY LINK PILLAR,S/L & MEN (L) LETTER
PI1LVSP14−6SL
1037−1 S17319
1 1 1
67 U1285345 * 3 WAY PILLAR & S/L Pl1 LVSP9−6SL 1
69 U1285346 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
REPLACE NO.4 PIT & J’BOX AS REQ’D
CU/SC QTY
EQUIPMENT SCHEDULE - SERVICE PILLARSLOCATION STN NO. SITE I.D. EX REC IN SIZE AND DESCRIPTION
COMP I.D.
REMARKS
UNDARRA ST 71 U1285347 * 2 WAY PILLAR, S/L & MEN Pl1LVSP4−6SL
1011−2 1 1
72 U1285348 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
73 U1285349 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
74 U1285350 * 3 WAY PILLAR & S/L Pl1 LVSP9−6SL 1
75 U1285351 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
76 U1285352 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
77 U1285353 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
104 U1285354 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
146 U1285355 * 3 WAY PILLAR & S/L Pl1 LVSP9−6SL 1
103 U1285356 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
101 U1285357 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
102 U1285358 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
100 U1285359 * 3 WAY PILLAR & S/L Pl1 LVSP9−6SL 1
MOONDARRA ST 93 U1285360 * 3 WAY PILLAR & S/L Pl1 LVSP9−6SL 1
94 U1285361 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
96 U1285362 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
97 U1285363 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
MCDONNEL LA 98 U1285364 * 1 WAY PILLAR, S/L & MEN Pl1LVSP2−6SL
1011−21 1
MOONDARRA ST 151 LP1285365 *2 WAY LINK PILLAR,S/L & MEN (L) LETTER
PI1LVSP14−6SL
1037−1 S17319
1 1 1
99 U1285366 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
301 U1298681 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
109 U1285367 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
110 U1285368 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
111 U1285369 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
112 U1285370 * 1 WAY PILLAR, S/L & MEN Pl1LVSP2−6SL
1011−21 1
113 U1285371 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
108 U1285372 * 1 WAY PILLAR, S/L & MEN Pl1LVSP2−6SL
1011−21 1
105 U1285373 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
106 U1285374 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
MILLSTREAM PL 114 U1285375 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
115 U1285376 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
116 U1285377 * 2 WAY PILLAR, S/L & MEN Pl1LVSP4−6SL
1011−2 1 1
117 U1285378 * 3 WAY PILLAR & S/L Pl1 LVSP9−6SL 1
118 U1285379 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
130 U1285380 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
121 U1285381 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
122 U1287382 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
123 U1287383 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
PATH OFF MILLSTREAM PL 124 U1287384 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
MILLSTREAM PL 125 U1287385 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
126 U1287386 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
127 U1287387 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
128 U1287388 * CROSS−ROAD PILLAR & S/L Pl1 LVSP12−6SL 1
129 U1287389 * 1 WAY PILLAR, S/L & MEN Pl1LVSP2−6SL
1011−21 1
DAVENPORT PL 133 U1287391 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
134 U1287392 * 2 WAY PILLAR & S/L Pl1 LVSP4−6SL 1
135 U1287393 * 1 WAY PILLAR, S/L & MEN Pl1LVSP2−6SL
1011−21 1
136 U1287394 * No.4 PIT & LID PIT4 1
137 U1287395 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
138 U1287396 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
139 U1287397 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
140 U1287398 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
141 U1287399 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
142 U1287400 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
143 U1287401 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
144 U1287402 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
145 U1287403 * No.4 PIT, LID & J’BOX (NO FUSE) SLM15528 1
SL FUSES S04434 82
GALVANISED PIPE BOLLARD 2 CONTRACTOR SUPPLY AS REQ’D
CABLE MARKER PLATES 1350−2 13
PATH OFF DAVENPORT PL & MOONDARRA ST
VARIOUS LOCATIONS
DRIVEWAY BETWEEN UNDARRA & MOONDARRA ST
F6/11/2010 A PRELIMINARY ISSUE R.R.
19/4/2011 B ZERO LOT LINES, YAWALPAH RD R.R.
INT. SL'S, POLES AT STNS 160/ 161
TO CLEAR D'WAYS.
19/5/2011 C YAWALPAH RD MEDIAN WIDENED R.R.
TO RETAIN EXIST SL'S
30/5/2011 D COUNCIL APPROVED R.R.
12/7/2011 E PILLAR STN 301 ADDED R.R.
16/8/2011 F R.R.
A130-07S0103674 7
GAINSBOROUGH GREEN STAGES 6.1 & 6.2YAWALPAH RD & SWAN RDPIMPAMA
MIRVAC PACIFIC LTD
W.Schardt
Venmark Pty Ltd
6/11/2010
SWP47.1
GOLD COAST
326 M7
REVDATE REVISION APP. DATE REV
Specialising in ElectricityReticulation and Street Lighting
Consulting Engineers - Electrical
APP.
BRISBANE:McDowall, QLD 405321 Nicholas Street,
Fax: (07) 3872 5566Tel: (07) 3872 5555
4 Wakefield Street
Fax: (07) 5442 2758
Woombye, QLD 4559
Tel: (07) 5442 1758
SUNSHINE COAST:
SCALE
UBD REF
COUNCIL REF
COUNCIL
SPECIFICATIONENERGEX
AND MUST NOT BE RETAINED, COPIED OR USED WITHOUT AUTHORITY.THIS DOCUMENT IS COPYRIGHT AND THE PROPERTY OF ROBIN RUSSELL & ASSOCIATES PTY LTD
DESIGNED
DRAWN
SIGNED
DATE
CLIENT
DESCRIPTION LOCATION
Email: [email protected] Email: [email protected]
APPROVED BYMap Gridwww.robrus.com.au 12
ENERGEX PROJECT No.
DRAWING No.
OF
SHEET No.
ROBIN RUSSELLRPEQ 1546
REVISION
A.B.N. 78 010 589 661& ASSOCIATES PTY. LTD.
A1@ A1 SIZE C 7N.T.S.
ELECTRICAL RETICULATION
BACK OFKERB
CHANNEL
LIP OFKERB &
BITUMEN
S/LIG
HT
INVERTOF KERB
NOTE 1:-
GOLD COAST CITY COUNCILSTREETLIGHT ALIGNMENT DETAIL
THE POLE ALIGNMENT SHALL ENSURE THAT 0.7m IS MAINTAINED BETWEEN THE INVERT OF KERB & THE FACE OF POLE.
0.7(NOTE 1)
LANTERN CUST. LANTERN CUST.
YAWALPAH RD 8L P1285198 P01 8.5 SBM SLM13216 1000 BOK SL1 S100L2 GCCC S21576 3 SLM5750 10.5 8
10L P1285199 P01 8.5 SBM SLM13216 1000 BOK SL1 S100L2 GCCC S21576 3 SLM5750 10.5 8
12L P1285200 P01 8.5 SBM SLM13216 1000 BOK SL1 S100L2 GCCC S21576 3 SLM5750 10.5 8
14L P1285201 P01 8.5 SBM SLM13216 1000 BOK SL1 S100L2 GCCC S21576 3 SLM5750 10.5 8
SWAN RD 18L P1285202 P01 7.0 SBM SLM13215CENTRE OF
MEDIANSL1 2 x S100L2 GCCC S21576 2 x 1.5 SLM5728 9 6
20L P1285203 P01 7.0 SBM SLM13215 0.7 IOK SL1 S150L2 GCCC S21577 1.5 SLM5734 9 6
21 P766550 P017.0
SBM7.0
SBMSL1 S100L2 S100L2 GCCC GCCC 3.0 3.0 RECOVER SL & PIT
19L P1285204 P01 7.0 SBM SLM13215CENTRE OF
MEDIANSL1 2 x S100L2 GCCC S21576 2 x 1.5 SLM5728 9
POWDER COAT POLE & OUTREACH BLACK
6
49L P1285205 P01 7.0 SBM SLM13215CENTRE OF
MEDIANSL1 2 x S100L2 GCCC S21576 2 x 1.5 SLM5728 9
POWDER COAT POLE & OUTREACH BLACK
6
50L P1285206 P01 7.0 SBM SLM13215CENTRE OF
MEDIANSL1 2 x S100L2 GCCC S21576 2 x 1.5 SLM5728 9
POWDER COAT POLE & OUTREACH BLACK
6
80L P1285207 P01 7.0 SBM SLM13215CENTRE OF
MEDIANSL1 2 x S100L2 GCCC S21576 2 x 1.5 SLM5728 9
POWDER COAT POLE & OUTREACH BLACK
6
82L P1285208 P01 7.0 SBM SLM13215CENTRE OF
MEDIANSL1 2 x S100L2 GCCC S21576 2 x 1.5 SLM5728 9
POWDER COAT POLE & OUTREACH BLACK
6
90L P1285209 P01 7.0 SBM SLM13215CENTRE OF
MEDIANSL1 2 x S100L2 GCCC S21576 2 x 1.5 SLM5728 9
POWDER COAT POLE & OUTREACH BLACK
6
88L P1285210 P01 7.0 SBM SLM13215CENTRE OF
MEDIANSL1 2 x S100L2 GCCC S21576 2 x 1.5 SLM5728 9
POWDER COAT POLE & OUTREACH BLACK
6
91L P1285211 P01 7.0 SBM SLM13215CENTRE OF
MEDIANSL1 2 x S100L2 GCCC S21576 2 x 1.5 SLM5728 9
POWDER COAT POLE & OUTREACH BLACK
6
GAINSBOROUGH DR 45L P1285212 P01 7.0 BPM SLM5637 900 BOK SL1 S150L2 GCCC S21577 4.5 SLM5757 9POWDER COAT POLE & OUTREACH BLACK
28
26L P1285213 P01 7.0 BPM SLM5637 900 BOK SL1 S150L2 GCCC S21577 4.5 SLM5757 9POWDER COAT POLE & OUTREACH BLACK
6
41L1 P1285214 P01 7.0 BPM SLM5637 900 BOK SL1 S150L2 GCCC S21577 4.5 SLM5757 9POWDER COAT POLE & OUTREACH BLACK
6
29L P1285215 P01 7.0 BPM SLM5637 900 BOK SL1 S150L2 GCCC S21577 4.5 SLM5757 9POWDER COAT POLE & OUTREACH BLACK
21
38L P1285216 P01 7.0 BPM SLM5637 900 BOK SL1 S150L2 GCCC S21577 4.5 SLM5757 9POWDER COAT POLE & OUTREACH BLACK
6
32L P1285217 P01 7.0 BPM SLM5637 900 BOK SL1 S150L2 GCCC S21577 4.5 SLM5757 9POWDER COAT POLE & OUTREACH BLACK
6
37L P1285218 P01 7.0 BPM SLM5637 900 BOK SL1 S150L2 GCCC S21577 4.5 SLM5757 9POWDER COAT POLE & OUTREACH BLACK
10
GREENMOUNT ST 52L P1285219 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 6
57L P1285220 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 6
59L P1285221 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 6
64L2 P1285222 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 24
64L1 P1285223 P01 4.5 ESTATE SLM14770 900 BOK SL1 M80D3L2 GCCC S21535 0.5 5.1 BLACK AVENUE 14
41L2 P1285225 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 6
LAMINGTON PL 65L P1285226 P01 4.5 ESTATE SLM14770 3.65 RP BDY SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 6
67L2 P1285227 P01 4.5 ESTATE SLM14770 3.65 RP BDY SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 30
UNDURRA ST 76L P1285228 P01 7 BPM SLM5637 900 BOK SL1 S100L2 GCCC S21576 1.5 SLM5734 9POWDER COAT POLE & OUTREACH BLACK
31
73L P1285229 P01 4.5 ESTATE SLM14770 900 BOK SL1 M80D3L2 GCCC S21535 0.5 5.1 BLACK AVENUE 24
71L P1285230 P01 4.5 ESTATE SLM14770 900 BOK SL1 M80D3L2 GCCC S21535 0.5 5.1 BLACK AVENUE 25
104L P1285231 P01 4.5 ESTATE SLM14770 900 BOK SL1 M80D3L2 GCCC S21535 0.5 5.1 BLACK AVENUE 14
101L P1285232 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 12
99L P1285233 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 18
MOONDARRA ST 93L P1285234 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 19
97L P1285235 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 6
96L P1285236 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 37
151L P1285237 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 19
100L P1285238 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 20
110L P1285239 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 19
111L P1285240 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 6
113L P1285241 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 20
106L2 P1285242 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 26
DRIVEWAY 106L1 P1285243 P01 4.5 ESTATE SLM147701.0 BEHIND
D’WAYSL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 18
105L P1285244 P01 4.5 ESTATE SLM147701.0 BEHIND
D’WAYSL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 18
McDONNELL LA 98L P1285245 P01 4.5 ESTATE SLM14770 3.65 FROM BDY SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 6
87L P1285246 P01 4.5 ESTATE SLM14770 3.65 FROM BDY SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 6
MILLSTREAM PL 67L1 P1285247 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 6
115L P1285248 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 20
116L P1285249 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 6
118L P1285250 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 6
119L1 P1285251 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 37
119L2 P1285252 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 35
121L P1285255 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 30
123L P1285256 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 24
125L P1285257 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 23
129L P1285258 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 6
m 130L P1285259 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 24
133L1 P1285260 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 32
133L2 P1285261 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 21
134L P1285262 P01 4.5 ESTATE SLM14770 900 BOK SL1 M50D3L2 GCCC S21531 0.5 5.1 BLACK AVENUE 26
PATH IN PARK 34L P1285264 P01 5 HINGED SLM20070 900 BOK SL1 M50AL2 GCCC S21522 0.5 5.1 BLACK HINGED POLE 30
124L1 P1285265 P01 5 HINGED SLM20070 900 BOK SL1 M50AL2 GCCC S21522 0.5 5.1 BLACK HINGED POLE 16
124L2 P1285266 P01 5 HINGED SLM20070 900 BOK SL1 M50AL2 GCCC S21522 0.5 5.1 BLACK HINGED POLE 48
137L P1285269 P01 5 HINGED SLM20070 900 BOK SL1 M50AL2 GCCC S21522 0.5 5.1 BLACK HINGED POLE 6
138L1 P1285270 P01 5 HINGED SLM20070 900 BOK SL1 M50AL2 GCCC S21522 0.5 5.1 BLACK HINGED POLE 6
138L2 P1285271 P01 5 HINGED SLM20070 900 BOK SL1 M50AL2 GCCC S21522 0.5 5.1 BLACK HINGED POLE 52
139L1 P1285272 P01 5 HINGED SLM20070 900 BOK SL1 M50AL2 GCCC S21522 0.5 5.1 BLACK HINGED POLE 30
139L2 P1285273 P01 5 HINGED SLM20070 900 BOK SL1 M50AL2 GCCC S21522 0.5 5.1 BLACK HINGED POLE 23
140L P1285274 P01 5 HINGED SLM20070 900 BOK SL1 M50AL2 GCCC S21522 0.5 5.1 BLACK HINGED POLE 6
141L P1285275 P01 5 HINGED SLM20070 900 BOK SL1 M50AL2 GCCC S21522 0.5 5.1 BLACK HINGED POLE 6
142L P1285276 P01 5 HINGED SLM20070 900 BOK SL1 M50AL2 GCCC S21522 0.5 5.1 BLACK HINGED POLE 6
143L P1285277 P01 5 HINGED SLM20070 900 BOK SL1 M50AL2 GCCC S21522 0.5 5.1 BLACK HINGED POLE 6
144L P1285278 P01 5 HINGED SLM20070 900 BOK SL1 M50AL2 GCCC S21522 0.5 5.1 BLACK HINGED POLE 6
145L1 P1285279 P01 5 HINGED SLM20070 900 BOK SL1 M50AL2 GCCC S21522 0.5 5.1 BLACK HINGED POLE 6
145L2 P1285280 P01 5 HINGED SLM20070 900 BOK SL1 M50AL2 GCCC S21522 0.5 5.1 BLACK HINGED POLE 41
NOTES 1201
1. ALL LIGHTS TO BE CONNECTED ON ENERGEX RATE 2.
2. CHECK CLEAR WITH ALL SERVICES BEFORE EXCAVATING.
POWDER COATING
LIGHT ABRASIVE BLAST, FOLLOWED BY POWDER COATING IN;
DULUX LUNAR ECLIPSE (BLACK)
PREFERRED POWDER COATER;
ELECTRO SEAL (Eric Newton)
5−7 Platinumn Street
CRESTMEAD Q 4132
PAINTING
STREET LIGHT LANTERNS ARE NOT TO BE PAINTED, AS PER ENERGEX POLICY.
STREET LIGHT SCHEDULE - RATE 2OUTREACH BRACKET
MOUNT HT (m)REC
(m)ERECT
(m)EXIST
(m)
LOCATIONSTN No.
SITE I.D.
POLE OR COMPONENTS
CU/SCCOMP
I.D.EXIST
(m)CU/SC
REC (m)
ERECT (m)POLE TYPE
ERECTALIGN
COMP I.D.
EXISTRECOVER
CU/SC
SL CABLE (m)
REMARKS