E421/E421FE422/E422F FRYERS
INSTALLATION, SERVICING
and USER INSTRUCTIONS
IMPORTANT
The installer must ensure that the installation of the appliance is in conformity with these instructions
and National Regulations in force at the time of installation.
Particular attention MUST be paid to -
BS7671 IEE Wiring Regulations
Electricity at Work Regulations
Health And Safety At Work Act
Fire Precautions Act
This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC
directives for the voltages stated on the data plate.
WARNING -THIS APPLIANCE MUST BE EARTHED
On completion of the installation these instructions should be left with the Engineer-in-Charge for
reference during servicing. Further to this, The Users Instructions should be handed over to the User,
having had a demonstration of the operation and cleaning of the appliance.
IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING
AND COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED
PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.
PREVENTATIVE MAINTENANCE CONTRACT
In order to obtain maximum performance from this unit we would recommend that a Maintenance
Contract be arranged with SERVICELINE. Visits may then be made at agreed intervals to carry out
adjustments and repairs. A quotation will be given upon request to the SERVICELINE contact
numbers below.
WEEE Directive Registration No. WEE/DC0059TT/PRO
At end of unit life, dispose of appliance and any replacement parts in a safe manner, via
a licenced waste handler. Units are designed to be dismantled easily and recycling of all
material is encouraged whenever practicable.
Falcon Foodservice EquipmentHEAD OFFICE AND WORKS
Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.
SERVICELINE CONTACT
Phone: 01438 363 000 Fax: 01438 369 900
T100798 Ref. 4
IMPORTANT INFORMATION
Warranty Policy Shortlist
Warranty does not cover :-
• Correcting faults caused by incorrect installation of a product.
• Where an engineer cannot gain access to a site or a product.
• Repeat commission visits.
• Replacement of any parts where damage has been caused by misuse.
• Engineer waiting time will be chargeable.
• Routine maintenance and cleaning.
• Gas conversions i.e. Natural to Propane gas.
• Descaling of water products and cleaning of water sensors where softeners/ conditioners are not fitted,
or are fitted and not maintained.
• Blocked drains
• Independent steam generation systems.
• Gas, water and electrical supply external to unit.
• Light bulbs
• Re-installing vacuum in kettle jackets.
• Replacement of grill burner ceramics when damage has been clearly caused by misuse.
• Where an engineer finds no fault with a product that has been reported faulty.
• Re-setting or adjustment of thermostats when unit is operating to specification.
• Cleaning and unblocking of fryer filter systems due to customer misuse.
• Lubrication and adjustment of door catches.
• Cleaning and Maintenance
• Cleaning of burner jets
• Poor combustion caused by lack of cleaning
• Lubrication of moving parts
• Lubrication of gas cocks
• Cleaning/adjustment of pilots
• Correction of gas pressure to appliance.
• Renewing of electric cable ends.
• Replacement of fuses
• Corrosion caused by use of chemical cleaners.
2
1.2.2 Clearances
The unit requires a clearance of at least 100mm to the
rear between unit and any combustible wall.
A minimum vertical clearance of 750mm should be
allowed between top edge of flue outlet and any
overlying combustible surface.
Important
If fryer is to be installed with other appliances then the
instructions for each unit should be consulted to
determine the necessary clearance to any combustible
wall or overlying surface.
Some appliances require greater clearance distances
than others. The largest clearance will therefore
determine overall distance for a complete suite of
adjoining appliances.
1.3 VENTILATION
The appliance ventilation requirements should be in line
with national and local regulations.
For multiple installations, requirements should be added
together. Installations should be made in accordance with
local and/or national regulations applying at the time.
A competent engineer must be used for any installation
work.
1.4 ELECTRICAL SUPPLY
The unit is supplied with a 2 metre, 5-core cord for
connection to a 400V 3N~ supply incorporating a suitable
isolating switch.
Phase Loading
L1: 29A, L2: 29A, L3: 29A
1.1 MODEL NUMBERS, NETT WEIGHTS
and DIMENSIONS
1.2 SITING
Each unit must be installed on a firm level floor in
a well-lit draught free position. The fryer should be
installed in a freestanding position to prevent any
possibility of sideways tipping under force. The means of
restraint may be the manner of installation, such as
connection to a battery of appliances or installing the
fryer in an alcove, or by separate means, such as
adequate ties.
1.2.1 Anti-tipping Bracket
An anti-tipping mechanism is also available as an
accessory. If fitted, the brackets must be installed to
locate the fryer in the correct position relative to any walls
as detailed below. Fixing holes are provided in fryer base
to accommodate the bracket. Details of fitting can be
found in Figure 1 below. The retaining chain has a quick
release eyelet. Attach securely to fixing point and secure
bracket to floor after alignment with bracket attached to
the fryer. Adjust bracket to slide below floor bracket.
Figure 1 - Anti-tipping Bracket
SECTION 1 - INSTALLATION
UNLESS OTHERWISE STATED, PARTS WHICH HAVE
BEEN PROTECTED BY THE MANUFACTURER ARE
NOT TO BE ADJUSTED BY THE INSTALLER.
Please ensure that any plastic coatings are removed prior
to use. Before operation, the pan requires to be
thoroughly cleaned and dried.
Discolouration of heated parts is caused by factory
testing to ensure a satisfactory unit. It does not affect
quality or performance.
ModelWidth
(mm)Depth
(mm)Height
(mm)Weight
(kg)
E421 / E422 400 800 880 72
E421F / E422F 400 800 880 83
3
SECTION 2 - ASSEMBLY and COMMISSIONING
The electrical cable must be connected in accordance
with the various regulations listed on the cover of this
manual.
2.1 ASSEMBLY
a) Unpack appliance
b) Unpack fryer baskets and accessories.
c) Place element guard and baskets in pan.
d) Level appliance and fit all service protection kits.
(Anti-tilt kit, if ordered as accessory).
2.2 CONNECTION TO AN ELECTRICAL SUPPLY
The supply cable must be connected to a suitable
isolator switch as follows:
Phase 1: Brown, Phase 2: Black, Phase 3: Grey
Neutral: Blue, Earth: Green/Yellow
2.3 STARTING UP
2.3.1 E421F Fryer Control Panel (See Figure 2)
Figure 2 – E421F Control Panel
1. ON/OFF and Temperature Control Knob
Temperature Selection (140 - 190°C). (Unit is off when inposition indicated).
2. Fat Melt Position
Feature for slow pulsed heating of solid fats.
3. Power on indicator.
4. Heat Demand Indicator (Amber)
illuminates when elements are on. Goes out when
desired temperature is reached.
2.3.2 E422F Fryer Control Panel (See Figure 3)
Figure 3 – E422F Control Panel
1. Four Digit LED Display
Displays Set temp, Actual temp, cook time remaining and
also used for programming purposes.
2. Program Button
Used to enter timer programme mode (to change each ofthe 4 pre-set timer select channels). (See Section 6).
3. Temperature Button
Used to view Actual/Set temperature and also to enter
Set temperature mode (See Section 6).
4. Timer Keys (1 – 4)
Used to start/cancel pre set cook times. Buttons 1 & 4
also used to change times or temperatures when in
either set mode (See Section 6).
5. Heat demand LED indicator
Illuminates when thermostat demands heat,
i.e. oil temperature is more than 2⁰C below programmed
set temperature. Will extinguish when desired setting is
reached.
2.4 PRE-COMMISSIONING CHECK
2.4.1 Checking Controller Operation
To check operation of controls, refer to Using The
Controller - Section 6.2.1.
4
12 3
4
12 3
4
1 13
4
4
2.5 TEMPERATURE LIMIT THERMOSTAT
The unit is equipped with additional temperature limit
thermostats, independent of the main controller.
In the case of operating thermostat failure, allowing oil
temperature to rise above predetermined legislation safe
zone (230⁰C), limit device will activate and cut power to
controller and elements.
To re-set temperature limit thermostat: (Refer to Figure 5)
E421F and E422F Models
a) Turn appropriate fryer pan ON/OFF switch to OFF
position.
b) Allow oil to cool below 150⁰C
c) To reset limit thermostat, remove black dust cap
located at element box rear. Push reset button using a
blunt instrument. (i.e. a pen) and replace cap.
d) Turn fryer ON/OFF switch to ON position.
e) Reselect temperature.
f) If limit thermostat reactivates carry out fault finding on
temperature control circuitry.
2.6 INSTRUCTION TO INSTALLER
After installing and commissioning appliance, please
hand Instructions to user or purchaser and ensure that
the person(s) responsible understands the instructions to
correctly operate and clean unit in a safe manner.
Emphasis should be given to safe operation and use of
drain valve and oil bucket. Oil bucket should not be
overfilled to allow safe movement. Oil should be allowed
to cool before any manual handling.
Note: The oil container may be heavy. Drain small
amounts at a time if necessary, before lifting container.
Manual handling regulations should be observed.
2.4.2 E421F & E422F - Additional Controls
(See Figure 4)
Figure 4 – E421F & E422F - Additional Controls
The following additional controls are located behind
cabinet door.
Fryer Pan ON/OFF Switches
Both pans are controlled by individual on/off switches that
cut power to appliance. Ensure both switches are off.
These are located as detailed in Figure 4.
2.4.3 E421F & E422F - Additional Controls
(See Figure 4)
Filtration Control
Filtration switch is located on centre of panel, behind
cabinet door.
Ensure oil return pipe is located in quick-release
valve housing.
Switch OFF appropriate on/off switch.
Switch ON filtration pump switch and allow oil to
return into pan.
Close drain valve when oil is filtered and allow pan
to fill.
Switch off filtration pump switch.
Temperature Safety Limiter Reset Button - 2 off
Located on rear of element box, below black dust cap,
refer to Figure 5.
Figure 5
safety button
5
SECTION 3 - SERVICING AND CONVERSION
BEFORE ATTEMPTING ANY SERVICING, TURN OFF
THE ELECTRICAL SUPPLY. TAKE STEPS TO ENSURE
THAT THESE CANNOT BE INADVERTENTLY TURNED
ON.
AFTER ANY MAINTENANCE TASK, CHECK THE
APPLIANCE TO ENSURE THAT IT PERFORMS
SAFELY AND CORRECTLY AS DESCRIBED IN
SECTION 2.4.
3.1 INTEGRAL COMPONENTS
The following parts must be checked and serviced
regularly:
1. Oil ingress to electrical components.
2. Visual inspection of components and fryer pan.
3. Temperature limit thermostat calibration.
3.2 ACCESS PROCEDURES
Before removal of any fryer components:
a) Ensure appliance electrical supply has been shut off
and cannot be accidentally turned back on.
b) Allow oil to cool before any operation that requires pan
to be drained.
c) Only use parts specified by the manufacturer.
d) All components replaced MUST be fully checked after
fitting to ensure safe operation.
e) A full pre-commissioning check as detailed in Section
2.4 should be carried out.
3.3 ELEMENTS
a) Remove five fixings from element box top and release
element cables.
b) Tilt element box and rest in upright position.
c) Remove four fixings from element mounting plate.
d) Remove element and seal.
e) Replace in reverse order.
3.4 TEMPERATURE CONTROLLERS
a) Remove control panel by undoing fixings at top and
bottom. Unplug control panel.
b) Disconnect electrics loom and remove fixings to
enable controller to be removed.
c) Carefully replace in reverse order.
3.5 MAINS ON and HEAT DEMAND NEONS
a) Remove control panel by undoing fixings at top and
bottom of control panel and unplug control panel.
b) Remove electrical connections from neon. Undo neon
retention nut.
c) Carefully replace in reverse order.
3.6 DRAIN VALVE
a) Ensure fry pot is empty. Refer to Section 8.
b) Remove nut from handle and lift handle off.
c) Remove front panel fasteners.
d) Disconnect wiring, noting all connections.
e) Remove front panel to access drain valve.
f) Undo drain pipe. Use appropriate size of spanner to
remove drain valve.
g) Replace in reverse order and check for oil leaks.
3.7 TEMPERATURE LIMIT THERMOSTAT
a) Remove element box cover plate.
b) Lift elements and secure in raised position.
c) Undo phial retention nut.
d) Release phial from retaining clip.
e) Disconnect phial wire plug and cut off plug.
f) Pull down phial to remove.
g) Carefully replace in reverse order. Check for any oil
leaks and that thermostat calibration is within
specification.
SECTION 4 - SPARES
When ordering spare parts, always quote appliance type
and serial number. This information will be found on the
data plate.
Manual control
Electronic controller
Element
Contactor
Solid State Relay
Operating thermostat
Safety thermostat
6
SECTION 5 - CRITICAL DIMENSIONS
7
.8
10
Wu
Set to 0.8
Set to 10 minutes
Set to Wu
Timer Pump
Settings
Set for 230V
SECTION 6 -
OPERATING INSTRUCTIONS
The fryers are of twin pan type and the following units are
covered by this manual.
E421 - Manual control model.
E422 - Four product key electronic control model.
E421F - Manual control model with built-in filtration.
E422F - Four product key electronic control model
with built-in filtration.
USE OF OIL / SHORTENING/SOLIDS
(COOKING MEDIUM)
As these are highly flammable when in their liquid state,
caution should always be taken when using cooking
medium.
Recommendation
PPE`s (Personal Protective Equipment) should be used
when cleaning or handling medium within this fryer.
Medium should not be overheated as this will increase
the risk of fire.
Note: Fryer is fitted with a thermal safety device. This will
stop heating of medium if the medium becomes
overheated.
This appliance will always fail safe.
Note: NEVER leave a working unit unattended.
Medium must always be maintained within fry pot.
Cold Medium - when filling with cold medium (see Figure6), DO NOT FILL MEDIUM PAST - MIN - LEVEL MARK
(Maximum Cold Fill Mark).
Figure 6
- MIN - Level Mark: Medium should NEVER be allowed
to drop below this mark. Should medium drop below this
mark, top up immediately or switch fryer OFF.
Hot Medium and Topping Up Medium
DO NOT FILL MEDIUM PAST - MAX - LEVEL MARK
(Maximum Hot Fill Mark). (See Figure 6).
Medium and Foodstuffs
As foodstuffs increase volume within fry pot - follow these
rules:
NEVER ADD WATER TO FRYER MEDIUM!
WARNING
No attempt must be made to operate appliance during a
power supply failure.
Please ensure that any plastic coated items are removed
prior to use. Before operation, pan requires to be
thoroughly cleaned and dried.
Discolouration of heated parts is caused by factory
testing to ensure unit is satisfactory. It will not affect
quality or performance.
All Models
An electronic thermostat with temperature probe is fitted.
The operating thermostat automatically controls oil
temperature. The temperature limit thermostat ensures
that the oil will not reach a dangerous temperature level.
If limit thermostat should activate during operation,
an investigation to determine the reason must be carried
out by a qualified technician.
6.1 APPLIANCE CONTROLS
Refer to Sections 2.4.1, 2.4.2 and 2.4.3 for controls
layout and description.
6.2 OPERATION
Safety Precautions
The installer must fit an isolator switch on unit electrical
supply.
The user MUST be familiar with location and operation of
isolalator switch for shutting off electrical supply in event
of an emergency.
6.2.1 Frypot Filling Instructions
Remove lid (if fitted) and baskets and set these aside.
Ensure pan is clean and completely dry. Ensure also that
drain valve is closed. Pour clean, cold oil to - MIN - pan
level mark on element guard/basket support grid.
8
Both Models (E421F/E422F)
a) Press appropriate ON/OFF pan switch ON (I).
b) Refer to individual unit info below.
(i) E421F only - Turn knob to select temperature.
(ii) E422F only - Is factory preset for a temperature of
180⁰C (See Section 6.3.1 for instructions on how tochange set temperature).
e) Refer to individual unit info below.
(i) E421F - Heat demand indicator will illuminate.
(ii) E422F only – Display will illuminate with figures 8888
for 2 seconds, CTT for 2 secs, r 06 for 2 seconds and
then displays Louu. Heat demand LED will illuminate.
6.2.2 Fryer maximum basket loading (Both models)
Pre-blanched chilled fries– 2 x 1.5kg baskets.
Frozen fries – 2 x 1.2kg baskets.
6.2.3 Using the Controller
E421F Models Only - Manually Operated
When unit has been switched on as detailed in
Section 6.2.1 above, fryer may be operated as follows.
Oil temperature will be governed by controller to desired
set temperature, selected by user on control knob.
E422F Models only – Programmable
When unit is lit as detailed in Section 6.2.1 lighting
instructions above, fryer may be operated as follows:-
NOTES:
1) The oil temperature will be governed by controller at a
factory preset temperature of 180⁰C.
See Section 6.3.1 for details of how to change set
temperature.
2) When actual temperature is within 10⁰C of set point,
display indicates redy. See Section 7.3 for details of
how to display actual or set temperature.
3) Before carrying out any cooking operations, controller
should be set up for particular application of use
(e.g. up to four timer programmes, product fryingtemperature, ⁰C/⁰F). This can all be carried out using
the following guide in Section 6.3.2.
Operating the Controller:
a) To start a timing cycle: Press any product key
(1 to 4) to start a timing cycle. If key is programmed,
correct time will display and will immediately start to
count down. LED above key will flash. DONE will
display when cook cycle ends and alarm will sound.
If DONE is displayed immediately and alarm sounds,
key has not been programmed See Section 6.3.2 for
programming details.
b) To stop a timing cycle: Press and hold an active
product key for 3 seconds, or press key 3 times within
2 seconds.
c) Respond to a DONE alarm: Cancel signal by pressing
same product key used to start timing cycle.
d) Multiple timing cycles: If a second or third product
key is pressed while first is still active, shortest time
remaining key is displayed and only LED above key
flashes, other(s) remain constantly lit. Once shortest
time programme ends and is accepted, next shortest
is displayed and LED above flashes. Note: All product
key timers will count down although not displayed until
shorter one ends.
e) Action Alarms (Shake, etc.): If control is programmed
for action alarm, this will signal at a pre-set time
during timing cycle. The signal, a dual-rhythm
beeping, will last 5 seconds and then self-cancel.
The display will flash action alarm time and will
continue counting towards 0:00.
f) Viewing Actual / Set Temperatures: Press
temperature key once to display “AXXX” where XXX
is actual temperature (°C or °F depending on controllerprogramming, see Section 6.3.1). Press
temperature key again within 5 seconds to display
“PXXX” where XXX is programmed set temperature
controller (°C or °F depending on how controller isprogrammed – See Section 6.3.1). If temperature key
is not pressed again within 5 seconds, display returns
to idle or timer mode.
9
6.3 PROGRAMMING THE E422F
Display Descriptions
Louu
Controller is in operating mode. Actual vat temperature is
more than 10°C below programmed vat temperature.
rEdy
Controller is in operating mode. Actual vat temperature is
within proper cooking temperature range. The vat is ready
to start a cook cycle.
HI
Controller is in operating mode. Actual vat temperature is
more than 10°C above programmed vat temperature.
Prob
Control probe is either open circuited or short circuited.
Display will be accompanied by an audible alarm if
shorted. Check or replace probe.
2:30
The control is in operating mode and a cook cycle is in
progress.
done
The control is in operating mode and a cook cycle has
been completed. Display will be accompanied by a
pulsing audible alarm.
6.3.1 Programming temperature set point and
temperature scale. (Factory set for 180⁰C, range available is 30⁰C to 190⁰C)
a) Press and hold temperature key for 3 seconds.
“Prog” will be displayed. Then press DOWN (key 1)or UP (key 4) key.
b) The display will show either “⁰C” or “⁰F” (degreescelsius or degrees fahrenheit). Once desired
temperature scale is displayed, press temperature key
to accept/enter.
c) Display will now alternate between “Sett” and
“XXXZ” (where X denotes temperature andZ indicates temperature scale).
d) Adjust temperature using DOWN (key 1) and UP (key4) keys. The longer key is pressed, the faster
temperature scrolls.
e) When desired temperature has been reached, press
temperature key to accept/enter.
f) To exit temperature programming, press temperature
key again.
6.3.2 Programming a Product Cycle Time
and Action Alarm
a) Press and hold P key for 3 seconds. “Prog” will be
displayed. Note: Programming mode will exit
automatically if no keys are pressed within 2 minutes.
b) Select a product key to program (1 to 4). The display
will alternate between “ti-z” and “X:XX” where z is
the number of key pressed and X:XX is set time in
minutes and seconds.
c) Adjust the time up or down using the DOWN (key 1)and the UP (key 4) keys. The longer key is held, the
faster time will scroll.
d) When set time is reached, press P key to
accept/enter.
e) The display will now alternate between “PrEz” and
“X:XX” where z is number of key pressed and X:XX
is action alarm time in minutes and seconds.
NOTE: The time entered here is time action required
before end of total cycle time entered above. If NO
action time is required, leave at “0:00”. Adjust time as c)
above.
f) Once desired time is reached, press P key to
accept/enter.
g) “Prog” will again be displayed and another product
key can be selected for programming. Repeat above
steps. When no more keys are required to be
programmed and “Prog” is displayed, press P key to
exit programming mode and return to idle mode.
SECTION 7 -
CHANGING THE OIL
Warning
After filtering, wait 30 seconds before removing bucket.
When draining, ensure that oil has time to strain through
strainer basket. Heavily unfiltered oil may overflow.
Warning
If oil is not emptied on a regular basis or if oil is left in
receptacle, it may solidify and overflow or spill on to the
kitchen floor to create a hazard.
7.1 STARTING THE FILTRATION PROCESS
1. Turn unit off at appropriate ON/OFF pan switch and
allow oil to cool below 170°C (or if cold, heat tominimum temperature of 60°C). Open cabinet door
and pull filter bucket forward.
10
2. Ensure bucket is clean and emptied of all oil and
debris. Refer to Section 8 for details of how to clean
filter components.
3. Ensure strainer and microfilter are clean and dry.
4. With strainer and microfilter in position, slide bucket
back on to runner cradle and back into fryer to engage
with pump.
Please Note
Warning
Do not handle filter components or adjacent surfaces
when pump is operating.
Components will remain hot for a period after filtering.
Allow to cool. Use of PPE's is recommended.
7.1.1 E421F and E422F Models
Note: With cabinet door open, filter pump switch is
in centre of control panel. (Refer to Figure 4).
1. Ensure appropriate appliance pan on/off switch is in
OFF position.
2. Allow oil to cool for approximately 15 - 20 minutes.
3. Position bucket and filters and ensure these are clean
and dry.
4. Open drain valve.
5. Allow oil to drain from pan.
6. Remove element guard from pan.
7. Raise elements with the aid of element lifting tool.
Please note: Elements and guard may still be hot!
8. Remove any fringdebris from pan.
9. Lower elements.
10. Activate oil pump by means of filter pump switch to
return oil to pan.
11. Leave to cycle for a few minutes before closing drain
valve.
12. Allow pan to fill with oil.
13. Once oil has been returned to pan, switch oil pump off
by means of filter pump switch.
14. Replace element guard.
15. Top up oil to correct level.
SECTION 8 -
CLEANING and MAINTENANCE
RECOMMENDATION
Personal protective equipment (PPE's) should be used
when cleaning or handling medium within this appliance.
WARNING - NEVER PUMP WATER THROUGH THE
FILTRATION PUMP AT ANY TIME!
Warning
The fryer is supplied with castors at rear and should be
connected to supply piping by means of a connector for
moveable appliances. An anti-tipping restraint can be
attached to unit and, if so, this must be disconnected
before fryer is moved. Ensure restraint is re-connected
when unit is returned to original position.
Moving the unit with hot or cold oil in fry pot can be
dangerous to the operator. Scalding could occur. Spilled
oil or fat on a kitchen floor could cause slipping accidents
and any such deposit should be cleaned up straight away.
To prevent any such hazard, DO NOT move fryer until all
liquid has been drained from fry pot.
The following procedure should be undertaken,
AT LEAST DAILY.
IMPORTANT: Disconnect electrical supply before any
cleaning is undertaken.
Warning
Oil must be allowed to cool to a safe temperature before
draining. Do not overfill draining receptacle.
THE APPLIANCE MUST NOT BE CLEANED WITH A
JET OF WATER OR BE STEAM CLEANED. DO NOT
USE ACID OR HALOGEN-BASED (e.g. chlorine)DESCALING LIQUIDS, FLAMMABLE LIQUIDS,
CLEANING AIDS OR CLEANING POWDERS.
Stainless Steel Surfaces
It should be noted that certain scouring pads including
nylon types, could easily mark stainless steel.
Care should be exercised during cleaning process.
When rubbing stainless steel with a cloth, always rub
along in grain direction.
11
8.1 CLEANING THE APPLIANCE
1. Carry out actions as detailed in Section 8.
2. Switch unit off and drain oil from appropriate pan.
3. Remove baskets and element guard. Soak these
components in hot soapy water.
4. Raise elements using tool provided (located behindunit door). Rest elements on rear support bar.
5. With drain valve open, remove any traces of debris
from fry pot using a clean, damp cloth.
NOTE: Care should be taken not to damage sensors that
are secured to elements.
6. Remove strainer and microfilter, soak these in hot
soapy water.
7. Wash, rinse and dry removed items thoroughly.
Set these aside.
8. Close drain valve.
9. Fill fry pot 3/4 full with hot water.
10. Clean pan using a soft, clean cloth and hot soapy
water, rub away any stubborn staining with a
scouring pad and suitable detergent.
11. Open drain valve. Allow water to drain into bucket
below.
12. Use clean water to rinse fry pot and dry thoroughly.
13. Close drain valve.
14. Lower elements back into fry pot and replace element
guard and baskets.
15. Remove oil bucket by pulling forward then upward.
16. Use handles and lift oil bucket to sink.
17. Pour away soiled water.
18. Thoroughly wash, rinse and dry oil bucket and oil
suction pipe.
19. Replace strainer and micro-filter in oil bucket and
return oil bucket to cradle.
20. Fill fry pot with clean oil to - MIN - mark. Refer to
Section 7.2.
SECTION 9 - PREPARATION OF
SOLID FATS/SHORTENING
COOKING HINTS
Allow approximately 6 minutes for unit to heat up from
cold to required operating temperature.
Choice of Frying Medium
Select a top quality medium to obtain optimum results.
Shortening or solid fats can be used if necessary.
Solid fats MUST be heated carefully. Solid fat has a lower
smoke point temperature than shortening.
E421F fat melt cycle pulses heat into the fryer.
A quality shortening is a more stable frying medium.
It allows longer periods of use without smoking or
foaming and will also give food a better flavour.
Quality shortening has a higher flashpoint temperature
and will reduce gumming around the appliance.
WARNING - NEVER MIX SHORTENING AND SOLID
FAT!
Charging The Pan
Prior to operation, clean fry pot out using hot water and
detergent. Rinse out and dry thoroughly.
Ensure drain valve is closed. Fill fry pot with cold
shortening to - MIN - level mark on element guard.
Maximum oil level capacity is 2 x 10 litres.
Solid Fat
If solid fat is to be used, remove element guard. Cut fat
into small pieces. Place 9.2kg in each fry pot and pack it
down. Position element guard on top of fat.
Ensure FAT MELT CYCLE (E421F only) is selected for
this process.
Note
The element guard will lower slowly as solid fat melts.
Warning
If element guard does not lie flat, lift plate from centre
slightly and lower carefully ensuring that no splashing of
hot oil occurs.
Check that correct shortening level is achieved when all
solid fat has melted. The required temperature may then
be set.
Solid fat should always be heated this way to prevent
overheating and burning.
WARNING: It is dangerous to use shortening that is too
old. Such shortening has a reduced flash point
temperature and is prone to surge boiling.
CAUTION: To prevent surge boiling. DO NOT EXCEED
recommended loads or charge the pan with over-wet food
items. NEVER leave a working appliance unattended.
12
13
SECTION 10 - COOKING HINTS
Frying food involves many variables and the following
information is a guide only.
1. Ensure frying medium is clean and free of debris.
2. When topping up with oil, ensure oil level does not
exceed - MIN - when cold and - MAX - line when hot.
3. Never overfill baskets with food product.
4. Filter oil as often as is practically possible. Remember,
this can be done whilst oil is below 180°C.
5. It is advised that a skimmer is used continuously
between frying batches of food to remove any floating
debris. Failure to do this may result in oil becoming
bitter to taste.
6. During quiet spells, it is recommended that thermostat
is turned down to a lower setting. This will conserve
energy in addition to extending expected oil life.
7. To ensure a good eating experience, fry food as close
to serving time as possible.
8. After serving and when fryer has been turned off,
replace lid to ensure that no foreign bodies can
contaminate frying medium.
14
3 2 1
3 2 1
MAIN
S TER
MIN
AL BL
OCK
MAIN
S TER
MIN
AL BL
OCK
CHAS
SIS LE
GCH
ASSIS
LEG
CONT
ROL P
ANEL
CONT
ROL P
ANEL
GREEN/YELLOW GREEN/YELLOW
BLUE BLUE
GREY GREY
BLACK BLACK
BROWN BROWN
5 COR
E MAI
NS IN
LET C
ABLE
5 COR
E MAI
NS IN
LET C
ABLE
1
12
23
3
4
45
5
6
6
7
7
8
8
9
9
1010
1010
1111
1111
1212
1212
1313
1313
1414
1414
1515
15151616
1616
1717
1717
1818
1818
2222
33332222
2121
3131
32323232
4444
3737
3737
3939
39394040
40404242
4242
4343
4646
4747
4848
53535353
29292020
3434 23234444
2424
BALL
AST
BALL
AST
RESIS
TOR
RESIS
TOR
102
102
103
103
104
104
9090
91919292
TO CO
NTRO
L PAN
ELTO
CONT
ROL P
ANEL
WIRI
NG LO
OMW
IRING
LOOM
(BW
4918
3)(B
W49
183)
PROB
EPR
OBE
ON/O
FF SW
ITCHE
SON
/OFF
SWITC
HES
2323
2626
2A2A A/S F
USE
A/S F
USE
4545
3030 33332727
9 WAY
MAL
E PLU
G HO
USIN
G9 W
AY M
ALE P
LUG
HOUS
ING
(MAT
E WITH
CONT
ROL P
ANEL
)(M
ATE W
ITH CO
NTRO
L PAN
EL)
78
9
45
632
1
5959
59596060
6060
BALL
AST
BALL
AST
RESIS
TOR
RESIS
TOR
2626
78
9
45
632
1
9 WAY
MAL
E9 W
AY M
ALE
PLUG
HOU
SING
PLUG
HOU
SING
(MAT
E WITH
(MAT
E WITH
CONT
ROL P
ANEL
)CO
NTRO
L PAN
EL)
2929
58585757
5757
5858
47474545
SAFE
TY ST
ATSA
FETY
STAT
NEUT
RAL
NEUT
RAL
BUS B
ARBU
S BAR
2121
SAFE
TYSA
FETY
CONT
ACTO
RCO
NTAC
TOR
A2A2A1A1
SAFE
TYSA
FETY
CONT
ACTO
RCO
NTAC
TOR
A1A1A2A2
3838
OPERATING POWER OPERATING POWERSWITCH SWITCH
OPERATING POWER OPERATING POWERSWITCH SWITCH
3030
3131
3838
2424
2727
2A2A A/S F
USE
A/S F
USE
4646
4848
SAFE
TY ST
ATSA
FETY
STAT
3434
RED
NEON
RED
NEON
RV10
1RV
101
WIR
ING
DIA
GR
AM
fo
r E
421
15
240V
240V
0V0V0V0V
24V
24V
3 2 1
3 2 1
MAIN
S TER
MIN
AL BL
OCK
MAIN
S TER
MIN
AL BL
OCK
CHAS
SIS LE
GCH
ASSIS
LEG
4343
CONT
ROL P
ANEL
CONT
ROL P
ANEL
GREEN/YELLOW GREEN/YELLOW
BLUE BLUE
GREY GREY
BLACK BLACK
BROWN BROWN
5 COR
E MAI
NS IN
LET C
ABLE
5 COR
E MAI
NS IN
LET C
ABLE
1 12
23
3
4
45
5
6
6
7
7
8
8
9
9
1010
1010
1111
1111
1212
1212
1313
1313
1414
1414
1515
15151616
1616
1717
1717
1818
1818
2222
33332222
2121
2929
3030
3131
3838
32323232
3737
3737
3939
39394040
40404242
4242
4343
4646
47474848
53535353
7070
7070
7171
7171
7272
4444
7373
7373
7474
7474
2121
4545ON
/OFF
SWITC
HES
ON/O
FF SW
ITCHE
S
PROB
EPR
OBE
TO CO
NTRO
L PAN
ELTO
CONT
ROL P
ANEL
WIRI
NG LO
OMW
IRING
LOOM
(BW
4927
1)(B
W49
271)
92929191 9090
104
104
103
103
102
102
2323
2626
2A A
/S FU
SE2A
A/S
FUSE
3030 333327279 WAY
MAL
E9 W
AY M
ALE
PLUG
HOU
SING
PLUG
HOU
SING
(MAT
E WITH
(MAT
E WITH
CONT
ROL P
ANEL
)CO
NTRO
L PAN
EL) 7
89
45
632
1
6363
6767
2626
78
9
45
632
1
9 WAY
MAL
E9 W
AY M
ALE
PLUG
HOU
SING
PLUG
HOU
SING
(MAT
E WITH
(MAT
E WITH
CONT
ROL P
ANEL
)CO
NTRO
L PAN
EL)
2929
6060
6666
47474545
SAFE
TY ST
ATSA
FETY
STAT
NEUT
RAL
NEUT
RAL
BUS B
ARBU
S BAR
SAFE
TYSA
FETY
CONT
ACTO
RCO
NTAC
TOR
A2A2A1A1
TRAN
SFOR
MER
TRAN
SFOR
MER
64646565
6060
6363
6262 6161
65656868
6868 2323
20202020
4444 2424
6464
7272
6161
6666TO
CONT
ROL P
ANEL
TO CO
NTRO
L PAN
ELSE
E BW
4927
1SE
E BW
4927
1
2A A
/S FU
SE2A
A/S
FUSE
SAFE
TYSA
FETY
CONT
ACTO
RCO
NTAC
TOR
A1A1A2A2
75753838
6262
6767
OPERATING POWER OPERATING POWERSWITCH SWITCH
OPERATING POWER OPERATING POWERSWITCH SWITCH
BA4
71
17
4
B A
3131
4646
2424
2727
2A A
/S FU
SE2A
A/S
FUSE
4848
SAFE
TY ST
ATSA
FETY
STAT
7575
WIR
ING
DIA
GR
AM
fo
r E
422
1616 56565454
1818A2A23636
A1A11515
B1B1
0.80.8 1010 F5555
24V ~
24V ~
110-
240V
~11
0-24
0V~
3 2 1
3 2 1 MAIN
S TER
MIN
AL BL
OCK
MAIN
S TER
MIN
AL BL
OCK
CHAS
SIS LE
GCH
ASSIS
LEG
4343
CONT
ROL P
ANEL
CONT
ROL P
ANEL
GREEN/YELLOW GREEN/YELLOW
BLUE BLUE
GREY GREY
BLACK BLACK
BROWN BROWN
5 COR
E MAI
NS IN
LET C
ABLE
5 COR
E MAI
NS IN
LET C
ABLE
1 12
23
3
4
45
5
6
6
7
7
8
8
9
9
1010
1010
1111
1111
1212
1212
1313
13131414
1414
1515
15151616
1616
1717
17171818
1818
2222
33332222
2121
2525
3131
32323232
44443535
5656
3737
3737
3939
39394040
40404141
4242
4242
4343
4646
47474848
53535353
2929
5454
230V
PUM
P TIM
ER23
0V PU
MP T
IMER
DETA
IL OF
230V
TIM
ERDE
TAIL
OF 23
0V TI
MER
SET D
IP SW
ITCH
TO 24
0VSE
T DIP
SWITC
H TO
240V
19191919
3434 23232020
2020 4444
2424
57575858
4646
PROB
EPR
OBE
TO CO
NTRO
L PAN
ELTO
CONT
ROL P
ANEL
WIRI
NG LO
OMW
IRING
LOOM
(BW
4918
3)(B
W49
183)
92929191
9090
104
104
103
103
102
102
ON/O
FF SW
ITCHE
SON
/OFF
SWITC
HES
28282525
5A A
/S FU
SE5A
A/S
FUSE
2323
2626
2A A
/S FU
SE2A
A/S
FUSE
4545
28283636
BBBA A
4563 2 A
PUM
P SW
ITCH
PUM
P SW
ITCH
1
3030 33332727
9 WAY
MAL
E PLU
G HO
USIN
G9 W
AY M
ALE P
LUG
HOUS
ING
(MAT
E WITH
CONT
ROL P
ANEL
)(M
ATE W
ITH CO
NTRO
L PAN
EL)
78
9
45
632
1
59596060
6060
5959
2626
78
9
45
632
1
9 WAY
MAL
E9 W
AY M
ALE
PLUG
HOU
SING
PLUG
HOU
SING
(MAT
E WITH
(MAT
E WITH
CONT
ROL P
ANEL
)CO
NTRO
L PAN
EL)
29295757
5858
47474545
SAFE
TY ST
ATSA
FETY
STAT
NEUT
RAL
NEUT
RAL
BUS B
ARBU
S BAR
2121
SAFE
TYSA
FETY
CONT
ACTO
RCO
NTAC
TOR
A2A2A1A1
SAFE
TYSA
FETY
CONT
ACTO
RCO
NTAC
TOR
A1A1A2A2
3838
OPERATING POWER OPERATING POWERSWITCH SWITCH
OPERATING POWER OPERATING POWERSWITCH SWITCH
3030
TILT S
WITC
HTIL
T SW
ITCH
31313838
24242727
2A A
/S FU
SE2A
A/S
FUSE
4848
SAFE
TY ST
ATSA
FETY
STAT
3434
RED
NEON
RED
NEON
RV10
1RV
101
41413535
9 WAY
MAL
E PLU
G HO
USIN
G9 W
AY M
ALE P
LUG
HOUS
ING
(MAT
E WITH
PUM
P LOO
M)
(MAT
E WITH
PUM
P LOO
M)
78
9
45
632
1
WIR
ING
DIA
GR
AM
fo
r E
421F
16
230V
PUM
P TIM
ER23
0V PU
MP T
IMER
1616
56565454
1818A2A23636
3535
A1A11515
B1B1
0.80.8 1010 Wu
Wu5555
240V
240V
0V0V0V0V
24V
24V
24V ~
24V ~
110-
240V
~11
0-24
0V~
3 2 1
3 2 1
MAIN
S TER
MIN
ALMA
INS T
ERM
INAL
BLOC
KBL
OCK
CHAS
SIS LE
GCH
ASSIS
LEG
4343
CONT
ROL P
ANEL
CONT
ROL P
ANEL
GREEN/YELLOW GREEN/YELLOW
BLUE BLUE
GREY GREY
BLACK BLACK
BROWN BROWN
5 COR
E MAI
NS IN
LET C
ABLE
5 COR
E MAI
NS IN
LET C
ABLE
1 12
23
3
4
4
5
5
6
6
7
7
8
8
9
9
1010
1010
1111
1111
1212
1212
1313
1313
1414
1414
1515
15151616
1616
1717
1717
1818
1818
2222
22223333
2121
2525
2929
3030
3131
32323232
3535
5656
3737
3737
3939
39394040
40404141
4242
4242
4343
4444
4646
47474848
53535353
7070
7070
7171
7171
7272
7272
7373
7373
7474
74747575
DETA
IL OF
230V
PUM
P TIM
ERDE
TAIL
OF 23
0V PU
MP T
IMER
SET D
IP SW
ITCH
TO 24
0VSE
T DIP
SWITC
H TO
240V
4444
19191919
2020
2020
2424
2323
102
102
103
103
104
104
9090
91919292
TO CO
NTRO
L PAN
ELTO
CONT
ROL P
ANEL
WIRI
NG LO
OMW
IRING
LOOM
(BW
4927
1)(B
W49
271)
PROB
EPR
OBE
ON O
FF SW
ITCHE
SON
OFF
SWITC
HES
6161
TRAN
SFOR
MER
TRAN
SFOR
MER
28282525
5A A
/S FU
SE5A
A/S
FUSE
2A A
/S FU
SE2A
A/S
FUSE
2323
2626
2A A
/S FU
SE2A
A/S
FUSE
28283636
BBBA A
4563 2 A
PUM
P SW
ITCH
PUM
P SW
ITCH
1
64646060
6565
6363
6262
6868
TO CO
NTRO
L PAN
ELTO
CONT
ROL P
ANEL
SEE B
W49
271
SEE B
W49
271
646465656868
3030
3333
2727
9 WAY
MAL
E PLU
G HO
USIN
G9 W
AY M
ALE P
LUG
HOUS
ING
(MAT
E WITH
CONT
ROL P
ANEL
)(M
ATE W
ITH CO
NTRO
L PAN
EL)
78
9
45
632
16767
63632626
78
9
45
632
1
9 WAY
MAL
EPLU
G HO
USIN
G9 W
AY M
ALEP
LUG
HOUS
ING
(MAT
E WITH
CONT
ROL P
ANEL
)(M
ATE W
ITH CO
NTRO
L PAN
EL)
29296666
6060
47474545
SAFE
TY ST
ATSA
FETY
STAT
NEUT
RAL
NEUT
RAL
BUS B
ARBU
S BAR
2121
SAFE
TYSA
FETY
CONT
ACTO
RCO
NTAC
TOR
A2A2A1A1
6666
6161
SAFE
TYSA
FETY
CONT
ACTO
RCO
NTAC
TOR
A1A1A2A2
75753838
6262
6767
OPERATING POWER OPERATING POWERSWITCH SWITCH
OPERATING POWER OPERATING POWERSWITCH SWITCH
BA4
71
17
4
B A
3131
4545
3838
2424
2727
2A A
/S FU
SE2A
A/S
FUSE
4646
4848
SAFE
TY ST
ATSA
FETY
STAT
4141
9 WAY
MAL
E PLU
G HO
USIN
G9 W
AY M
ALE P
LUG
HOUS
ING
(MAT
E WITH
PUM
P LOO
M)
(MAT
E WITH
PUM
P LOO
M)
78
9
45
632
1
WIR
ING
DIA
GR
AM
fo
r E
422F
17
18
RIGHT
AM
BER
RV10
0RE
D NE
ONRV
101
FIT TO
TERM
INAL
BLOC
K CON
NECT
ORIN
ELEM
ENT B
OX
FIT TO
ELEM
ENT B
OX
102
103
104
9192
90
RELA
Y
T6T1
0T9
T11
T8 CO
M
T7T2
T3
T12
T5
PROB
E
T4T1
G5 FA
STRO
N CO
NTRO
LLER
9598
85
84
93
96
9192
SEE D
RAW
ING
BW49
577
86
87
88
90
FIT TO
ELEM
ENT B
OX
9 WAY
FEMA
LEPL
UG H
OUSIN
G
12
3
45
6
78
9
96
9511
0
LEFT
AM
BER
RV10
010
7
87FIT TO
TERM
INAL
BLOC
K CON
NECT
ORIN
ELEM
ENT B
OX
9 WAY
FEMA
LEPL
UG H
OUSIN
G 98
7
65
4
32
1
9981
81
100
100
8810
8
104
RELA
Y
T6T1
0T9
T11
T8 CO
M
T7T2
T3
T12
T5
PROB
E
T4T1
G5 FA
STRO
N CO
NTRO
LLER
102
103
97
105
101
8510
6
9310
7
106
83 82
82
99
9710
9
108
8483
34
34
TO L1
(TER
MIN
AL BL
OCK)
E421/4
21F
Co
ntr
ol P
an
el W
irin
g D
iag
ram
19
9 WAY
FEMA
LE PL
UG H
OUSIN
G(M
ATE W
ITH M
AIN
LOOM
)
OPER
ATES
LH SI
DE EL
EMEN
T.
FAST
CTT
PROG
RAM
MABL
ECO
NTRO
LLER
FAST
CTT
PROG
RAM
MABL
ECO
NTRO
LLER
12
3
45
6
78
9
9 WAY
FEMA
LE PL
UG H
OUSIN
G(M
ATE W
ITH M
AIN
LOOM
)
82
82
101
101
102
103
99
100
100
99
8393
95
91 92
83
93
95
96
96
7
6
89
13
2
45
OPER
ATES
RH SI
DE EL
EMEN
T
FROM
TRAN
SFOR
MER
ON M
AIN
LOOM
64
64
FIT TO
TERM
INAL
BLOC
K CON
NECT
ORIN
ELEM
ENT B
OX
4 WAY
CRIM
PTE
RMIN
AL H
OUSIN
G
103
102
104
FIT TO
ELEM
ENT B
OX2 W
AY CR
IMP T
ERM
INAL
HOU
SING
2 WAY
CRIM
P TER
MIN
AL H
OUSIN
G
4 WAY
CRIM
PTE
RMIN
AL H
OUSIN
G
9291
90FIT
TO EL
EMEN
T BOX
FIT TO
TERM
INAL
BLOC
K CON
NECT
ORIN
ELEM
ENT B
OX
E422/4
22F
Co
ntr
ol P
an
el W
irin
g D
iag
ram
20
N E
43
TO EL
EMEN
TBO
X
L1 L2 L3
TO CO
NTRO
LPA
NEL
42
SAFE
TYCO
NTAC
TOR
A1 A2
SAFE
TYST
AT
G5 FA
STCO
NTRO
LLER
POW
ERNE
ONHE
ATNE
ONHE
ATNE
ON
A2A1OP
ERAT
ING
POW
ERSW
ITCH
2A FU
SE
2A FU
SE
ON/O
FFSW
ITCH
1
THER
MIST
ORPR
OBE
THER
MIST
ORPR
OBE
1315
17
2237
53
79
11
53
1
4546
24
6
4847
32
31
1416
18
40
39
810
12
20
24 23
29
30
96
9386
8483
91 92
101
2710
0
2695
98
99
338182
97
102
103
C5
C5
C9
C6
C6
G5 FA
STCO
NTRO
LLER
44 ON/O
FFSW
ITCH
2
C8 C7
BALL
AST
RESIS
TOR
1K5
BALL
AST
RESIS
TOR
1K5
C8 C7
58 57
60 59
88
108
87
107
104
90
34
105
110
20
3445
46
38
21
106
85
109
TILT
SWITC
H
CIR
CU
IT D
IAG
RA
M f
or
E421
21
MFILTR
ATIO
NPU
MP 41
C7
GR/Y
L
TILT
SWITC
H10
9
85
106
21
38
46 4534
20
110
105
34
9010
4
107
87
108
88
5960
5758
C7C8
BALL
AST
RESIS
TOR
1K5
BALL
AST
RESIS
TOR
1K5 C7C8
ON/O
FFSW
ITCH
2
44
G5 FA
STCO
NTRO
LLER
C6
C6
C9
C5
C5
103
102
9782
81 33
99
98
9526
100
27
101
9291
8384
8693
96
30
29
2324
20
1210
8
39
40
1816
14
31
32
4748
64
2
4645
13
5
119
7
53
3722
1715
13
THER
MIST
ORPR
OBE
THER
MIST
ORPR
OBE
ON/O
FFSW
ITCH
1
2A FU
SE
2A FU
SE
OPER
ATIN
GPO
WER
SWITC
H
A1 A2
HEAT
NEON
HEAT
NEON
POW
ERNE
ON
G5 FA
STCO
NTRO
LLER
SAFE
TYST
AT
A2A1
SAFE
TYCO
NTAC
TOR
42
TO CO
NTRO
LPA
NEL
L3L2L1
TO EL
EMEN
TBO
X
43EN
BLUE
BROW
N
PUM
P SW
ITCH
55 3656
16
1815A1
A2
TIMER
255A
FUSE
28
C9
54
35
54 3519 19
8382
CIR
CU
IT D
IAG
RA
M f
or
E421F
22
100
72
74 7370
6261
65
6066
6367
83
61
6766
68
2A FU
SE
N E43
TO EL
EMEN
TBO
X
L1 L2 L3
TO CO
NTRO
LPA
NEL
42
SAFE
TYCO
NTAC
TOR
A1 A2
SAFE
TYST
AT
CTT
CONT
ROLL
ER
A2A1OP
ERAT
ING
POW
ERSW
ITCH
2A FU
SE
2A FU
SE
ON/O
FFSW
ITCH
1
THER
MIST
ORPR
OBE
1315
17
2237
53
79
11
53
1
4546
24
6
48
47
32
31
1416
18
40
39
810
12
20
24 23
71
9693
91 92
33
2710
0
26
95
8210
199
102
103
C5
C5
CTT
CONT
ROLL
ER
44
ON/O
FFSW
ITCH
2
104
90
20
4546
38
21
TILT
SWITC
H71
3029
4 7 AB
BA74
72
73
74
75
3029
70
62
24V
TRAN
SFOR
MER
9
64
64
3
63 60 65
43
6
THER
MIST
ORPR
OBE
75
CIR
CU
IT D
IAG
RA
M f
or
E422
23
63
4
656063
34
6
64
924
VTR
ANSF
ORM
ER
62
7029
30
75
74
73
72
4 7 AB
BA74
2930
71
MFILTR
ATIO
NPU
MP 41
C7
GR/Y
L
TILT
SWITC
H
21
38
46 45
20
9010
4
ON/O
FFSW
ITCH
2
44
CTT
CONT
ROLL
ER
C5
C5
103
102
9910
182
95
26
100
27
33
9291
9396
71
2324
20
1210
8
39
40
1816
14
31
32
47
48
64
2
4645
13
5
119
7
53
3722
1715
13
THER
MIST
ORPR
OBE
THER
MIST
ORPR
OBE
ON/O
FFSW
ITCH
1
2A FU
SE
2A FU
SE
OPER
ATIN
GPO
WER
SWITC
H
A1 A2
CTT
CONT
ROLL
ER
SAFE
TYST
AT
A2A1
SAFE
TYCO
NTAC
TOR
42
TO CO
NTRO
LPA
NEL
L3L2L1
TO EL
EMEN
TBO
X
43EN
BLUE
BROW
N
PUM
P SW
ITCH
55 3656
16
1815A1
A2
TIMER
255A
FUSE
28
C9
5435
3519 19
2A FU
SE
68
6667
61
83
6763
6660
65
6162
707374
72
100
CIR
CU
IT D
IAG
RA
M f
or
E422F
24