DECS-200MOUNTING PLATE SOLUTIONS
COMPACT DIGITAL PRE-PACKAGED AVR MOUNTING PLATE SOLUTIONS FOR SYNCHRONOUS MACHINES
page 2
DECS-200 THE HEART OF YOUR SYSTEMWHEN RELIABILITY AND EASY SETTINGS ARE ESSENTIAL, YOU ARE LOOKING FOR DECS-200.
The DECS-200 is an excitation control system used to control the output voltage, vars or power factor of a synchronous generator by varying or controlling the amount of DC excitation applied to the generator’s exciter field. Suitable for virtually any size machine, the microprocessor-based DECS-200 is a total excitation control system in one enclosure. It contains all the functionality necessary to control, limit, and protect a generator from operating outside of the machine’s capability.
■ Microprocessor-based design ■ Up to 125Vdc output at 15Adc ■ 20 standard stability selections ■ PID Calculator ■ Paralleling compensation ■ Soft start build-up ■ Auto-tracking between operating modes ■ Minimum Excitation Limiter
■ Stator Current Limiter ■ Oscillography ■ Exciter Diode Monitoring (EDM) ■ Eight generator protection features ■ Front panel backlit LCD display ■ Side panel mounted RS-485 comm. port ■ True RMS sensing, single or three phase ■ 0.25% Voltage Regulation Accuracy ■ User customizable stability selection ■ U/F compensation or V/Hz Ratio Limiter ■ FCR Mode (Manual Mode) ■ Auto-tracking between 2 DECS-200 units ■ On and off-line Maximum Excitation Limiters ■ VAR and PF (Power Factor) Controllers ■ Sequence of Events Recording ■ Voltage Matching ■ Programmable output contacts ■ Front panel mounted RS-232 comm. port ■ Modbus protocol for RS-485 up to 1.2km ■ Setup from front panel HMI or by PC with free
BESTCOMSTM user-friendly setting software. ■ Meets C37.90.1-1989 for Surge Withstand and Fast
Transient ■ UL recognized, CSA certified, CE compliant, DNV
certified, GOST-R certified, Byelorussian certified ■ Two separate analog inputs for remote set point
control ■ Designed for applications ranging from 0 to 15 Amps ■ For applications up to 20 Amps, Basler DECS-200N
is available.
BASLER INTEGRATED SYSTEMSSAVE TIME AND GET THE MOST OUT OF YOUR INSTALLATIONWITH BASLER SOLUTIONS.
Ease, convenience, and performance are key for new installations and are essential when replacement of original aging excitation systems become necessary. DECS-200 solutions are of full-featured excitation systems equipped with all the functionality necessary to provide reliable operation of a synchronous machine. The DECS-200 AVR incorporates microprocessor technology and is the heart of Basler Electric pre-packaged excitation systems. Basler engineered quality solutions may be delivered on fully assembled mounting plates, ready for installation in your new or existing cubicle.
BASLER DECS-200MOUNTING PLATE SOLUTIONS
FULLY-EQUIPPEDSTANDARD SOLUTIONS
CUSTOM-DESIGNEDSOLUTIONS
24Vdc
POWER SUPPLY
SENSING CT
EITHER ON TERMINAL OR NEUTRAL SIDE
SENSING
VOLTAGE
TRANSFORMER
AC INPUT
POWER SUPPLY
VOLTAGE
MATCHING
INPUT
RS485
(MODBUS)
MANU
AL / A
UTOM
ATIC
MOD
ELO
WER
/ RA
ISE
SETP
OINT
STAR
T / S
TOP
EXCI
TATI
ONRE
SET
LOAD
PRE
POSI
TION
52G
(GEN
ERAT
OR C
IRCU
IT B
REAK
ER)
52L (
GRID
CIR
CUIT
BRE
AKER
)
DROO
P IN
HIBI
T (D
ECS)
ALAR
M RE
SET
(DEC
S)24
Vdc C
ONTR
OL V
OLTA
GE
52G
1A or 5A
BOOST CTs
(1or 2 CT)
85 to 264Vac
or90 to 350Vdc
POWER SUPPLYEXCITATION
CIRCUIT BREAKER
EXCITATION
CONTACTOR
DISCHARGE
RESISTOR
24Vdc
INTERNAL
POWER SUPPLY
FIELD FLASHING
CIRCUIT BREAKER
FIELD FLASHING
RESISTOR
FIELD FLASHING
CONTACTOR
CEX
CEX
UNDERVOLTAGE
DECS-200 (27)
OVERVOLTAGE
(OVR - 59)
BOOST
CONTACTOR
LOGIC
INTERFACE
AC/DC
DC
OUTPUT CONTACTS
OVERVOLTAGE (MOMENTARY)
PROGRAMMABLE
(DECS OUTPUT RELAY#3)
AVR FAIL “WATCHDOG ALARM”
UNDERVOLTAGE (MOMENTARY)
EXCITATION BREAKER TRIP
EXCITATION ON
EXCITATION BREAKER TRIP
27
ICRM-15
DECS-200
SINGLEDECS-200
DUAL DECS-200
page 3
These types of solutions are also available with Basler DECS-200N.
page 4
SINGLE DECS-200STANDARD MOUNTING PLATEYOUR FULLY-EQUIPPED SOLUTION.
SIN
GLE
LIN
E D
IAG
RA
M
Specific features: ■ Over Voltage Protection Relay (BE3-59T) with setting 110 to 150V
■ Universal Boost Circuit
■ Inrush Current Reduction Module (ICRM)
■ Field-Flashing Circuit
■ Current Sensing 1 or 5A
■ Wide range of control power supply
■ Shipping dimensions: 830 x 250 x 420mm ■ Net weight: 25kg | Shipping weight: 30kg
MECHANICAL DRAWING
24Vd
cPO
WER
SUP
PLY
SENS
ING
CTEI
THER
ON
TERM
INAL
OR
NEUT
RAL S
IDE
SENS
ING
VOLT
AGE
TRAN
SFOR
MER
AC IN
PUT
POW
ER S
UPPL
Y
VOLT
AGE
MATC
HING
INPU
TRS
485
(MOD
BUS)
MANUAL / AUTOMATIC MODE
LOWER / RAISE SETPOINT
START / STOP EXCITATION
RESET LOAD PREPOSITION52G (GENERATOR CIRCUIT BREAKER)
52L (GRID CIRCUIT BREAKER)
DROOP INHIBIT (DECS)
ALARM RESET (DECS)
24Vdc CONTROL VOLTAGE
GRID
52L
52G
1A or
5A
BOOS
T CT
s(1
or 2
CT)
85 to
264V
acor 90
to 35
0Vdc
POW
ER S
UPPL
Y
EXCI
TATI
ONCI
RCUI
T BR
EAKE
R
EXCI
TATI
ONCO
NTAC
TOR
DISC
HARG
ERE
SIST
OR
24Vd
cIN
TERN
ALPO
WER
SUP
PLY
FIEL
D FL
ASHI
NGCI
RCUI
T BR
EAKE
R
FIEL
D FL
ASHI
NGRE
SIST
OR
FIEL
D FL
ASHI
NGCO
NTAC
TOR
CEX
CEX
UNDE
RVOL
TAGE
DECS
-200
(27)
OVER
VOLT
AGE
(OVR
- 59
)
BOOS
TCO
NTAC
TOR
LOGI
C IN
TERF
ACE
AC/D
C DC
OUTP
UT C
ONTA
CTS
OVER
VOLT
AGE
(MOM
ENTA
RY)
PROG
RAMM
ABLE
(D
ECS
OUTP
UT R
ELAY
#3)
AVR
FAIL
“WAT
CHDO
G AL
ARM”
UNDE
RVOL
TAGE
(MOM
ENTA
RY)
EXCI
TATI
ON B
REAK
ER T
RIP
EXCI
TATI
ON O
N
EXCI
TATI
ON B
REAK
ER T
RIP
27
ICRM
-15
DEC
S-20
0
G
page 5
page 7
SIN
GLE
LIN
E D
IAG
RA
M
page 6
DUAL DECS-200STANDARD MOUNTING PLATEWHEN DOWNTIME IS NOT AN OPTION.
Specific features: ■ Dual Digital Excitation Control System 125V 15A with automatic
tracking between both controllers and provides transfer from master to back-up
■ Over Voltage protection Relay (BE3-59T) with setting 110 to 150V
■ Universal Boost Circuit | Field-Flashing Circuit
■ Inrush Current Reduction Module (ICRM)
■ Full Bumpless Transfer and Redundancy
■ Current Sensing 1 or 5A | 3 values of shunt available (5, 15 or 30A)
■ Over Excitation protection Relay (BE3-74SH)
■ Wide range of control power supply
■ Shipping dimensions: 830 x 820 x 450mm ■ Net weight: 39kg | Shipping weight: 60kg
MECHANICAL DRAWING
MANUAL / AUTOMATIC MODE
LOWER / RAISE SETPOINT
START / STOP EXCITATION
MASTER AVR
LOAD PREPOSITION52G (GENERATOR CIRCUIT BREAKER)
52L (GRID CIRCUIT BREAKER)
DROOP INHIBIT (DECS)
ALARM RESET (DECS)
BACK-UP AVR RESET
AC/D
C DC
24Vd
cPO
WER
SUPP
LY
85 to
264V
acor
90 to
350V
dcPO
WER
SUP
PLY
BOOS
TPO
WER
SUPP
LY(C
Ts)
BOOS
TCO
N-TA
CTOR
24Vd
cIN
TERN
ALPO
WER
SUP
PLY
DISC
HARG
ERE
SIST
OR
SHUN
T
BUILD
-UP
CEX
KB KB
CEX
KM
EXCI
TATI
ONCI
RCUI
T BR
EAKE
R
EXCI
TATI
ONCO
NTAC
TOR
AC IN
PUT
POW
ER S
UPPL
Y
SENS
ING
TRAN
SFOR
MER
3x10
0Vto
3x12
0V
1A or
5A
SENS
ING
CTEI
THER
ON
TERM
INAL
OR
NEUT
RAL S
IDE
VOLT
AGE
MATC
HING
INPU
TRS
485
(MOD
BUS)
OVER
VOLT
AGE
RELA
Y (5
9)
OVER
EXCI
TATI
ONRE
LAY
(1st
step -
76)
OVER
EXCI
TATI
ONRE
LAY
(2nd
step
- 76
)
OUTP
UT C
ONTA
CTS
UNDE
RVOL
TAGE
(MOM
ENTA
RY)
PROG
RAMM
ABLE
(D
ECS
OUTP
UT R
ELAY
#3)
AVR
FAIL
(BAC
K-UP
) “W
ATCH
DOG
ALAR
M”
EXCI
TATI
ON B
REAK
ER T
RIP
EXCI
TATI
ON O
N
EXCI
TATI
ON B
REAK
ER T
RIP
24Vd
c BRE
AKER
TRI
P
OVER
EXCI
TATI
ON (1
st LE
VEL)
OVER
EXCI
TATI
ON (2
nd LE
VEL)
PROG
RAMM
ABLE
(D
ECS
OUTP
UT R
ELAY
#2)
MAST
ER AV
R SE
LECT
ED
BACK
-UP
AVR
SELE
CTED
LOGI
C IN
TERF
ACE
DEC
S-20
0M
AST
ER
DEC
S-20
0B
AC
K-U
P
52L
52G
GRID
ICRM
-15
G
page 8
RELIABILITY, FLEXIBILITY, EASE OF OPERATIONBasler DECS-200 standard and customized solutions are designed to help you get the most out of your installation. We know that downtime is not an option and that is the reason why we decided to include an Inrush Current Reduction Module on our standard solutions to avoid any problems during power-up.Basler goes even further in ensuring that our solutions will fulfill your expectations. Our dedicated field service team can help you through commissioning, provide you with on-site training, and answer all your technical questions rapidly.
Inrush Current Reduction Module: ICRM
Applications where a PWM-type voltage regulator is powered by a PMG or a Station Bus, it is highly recommended to install an Inrush Current Reduction Module to minimize the amount of inrush current flow.
The ICRM (included on all MP-DECS-200 standard mounting plates) prevents damage to a protected voltage regulator during power-up by limiting inrush current to a safe level. Without inrush protection, the inrush current is limited only by the level of the power
Commissioning and technical support
Our team of field service technicians and engineers is available worldwide to help you through commissioning.
At Basler Electric, we understand what an emergency means to you. For that reason we structured our response capability to ensure that you get the answers you need within 48 hours.
■ Worldwide commissioning
■ Worldwide technical support
■ 24/7 hotline
■ On-site training
■ Hands-on training in our factory
source impedance. The lower is the impedance; the greater is the risk of damaging the regulator from excessive inrush current.
Devices with a pulse-width modulated (PWM) power stage are especially vulnerable to high inrush current due to a large amount of capacitance inherent to the design. Shunt-powered voltage regulators as well as those that use SCR-type power stages do not usually require the protection of an ICRM.
BESTCOMSTM software is provided free of charge with our products.Among its features are:
■ Easy file creation
■ Reduced learning curve
■ Additional logic elements
■ Settings optimization via PC
■ PID stability program
Download BESTCOMSTM at www.basler.com and explore its capabilities.
BESTCOMS Configuration window
BESTCOMSTM,USER-FRIENDLY INTERFACETRY OUR FREE INTUITIVE SOFTWARE AND WE ARE SURE YOU WILL ADOPT IT.
With Basler-designed graphical user interface BESTCOMSTM forget about complicated settings and updates. By providing you with an intuitive point-and-click software, we make sure you stay in control of your installation. The capabilities of this software make the configuration, and monitoring of your DECS-200 fast and efficient.
BESTCOMS Metering window
Create a settings scheme
Save it as a file
Upload it to the product at your convenience
1
2
3
page 9
page 10
RETROFIT SOLUTIONS FOR MINIMUM DOWNTIMEIMPROVE YOUR DECS-125-15 OPERATION PERFORMANCE WITH A DECS-200 RETROFIT SOLUTION.
DECS-125-15 has proven its efficiency and reliability through thousands of applications operating around the world. Basler Electric has designed a new mounting plate using the latest technology to replace your obsolete DECS-125-15. Our target: save you time and money. The installation of your retrofit mounting plate does not require electrical or mechanical modifications since it has the same connections (including droop and cross-current compensation on the same input) and footprint as the previous one. Plug it and play: you are done.
Increase generator efficiency and availability.Improved control modes and additional protective and limiting functions of the DECS-200 retrofit mounting plate increase generator efficiency and availability.
Control modes.
If a loss of sensing condition is detected, the DECS-200 mounting plate will act as a back-up source of regulation until repairs can be made. The DECS-125-15 provided this type of field current regulation only during test and commissioning. Moreover, the DECS-200 solution allows for minimum voltage variation on the generator output when switching between modes thanks to its ability to track the active mode by all non-active ones.
Protective and limiting functions.
Added protective features provide a reliable protection back-up source to your existing relaying scheme and contribute to the preservation of your generator’s integrity.
Extra limiting functions enable easier field commissioning by eliminating the need to modify generator limiters’ settings and protects the generator stator from overheating.
Enhance interaction between your system and your control room.Front side panel RS232 and side-mounted RS485 ports allow for enhanced communication capabilities on a DECS-200 retrofit mounting plate.
Benefit from fast and easy user setup via your PC with Basler’s software, BESTCOMSTM. As a part of it, Basler provides a PID selection software that will help you obtain maximum generator response and performance while achieving utmost stability through the input of basic generator parameters and the reception of pre-calculated PID values.
DECS-125-15 DECS-200Generator over-voltage Generator over-voltageLoss of sensing Loss of sensingInternal power stage over temperature Watchdog
Generator under-voltageField over-voltage and currentExciter diode monitoringLoss of field
Standard protective features.
FOR MORE OPTIONSGET A CUSTOM DESIGNCUSTOMIZED DECS-200 MOUNTING PLATES.
Basler Electric takes pride in providing their partners with solutions completely adapted to their needs. Should you have some specific requirements regarding the design of your mounting-plate, our engineers will take care of it. Basler Electric manufactures solutions for virtually all types of applications and environmental conditions. Ask for a customized solution and get Basler service as a bonus.
EXAMPLES OF PROPOSED OPTIONSTransducers PLC for added features and integrationAdaptation of sensing voltage Additional protective relaysFull dual sensing circuit Local / Remote control facilitiesFull dual power input Synchronization equipmentFull redundant AVR transfer Communication through ModbusFull dual control power Boost circuit supplied from batterySpecific connecting plugs Boost circuit supplied from CTs (with output limit adjustment control)
Specific terminals (spring or screw) Black startSpecific wiring (halogen free, flame retardant, cross section) Customized shape
Specific logic (more logic or information) Customized sizeFull control for alarms and faults Power system stabilization equipmentNegative forcing with DECS-200N Contact Basler for more options
Not only will the new system allow you to monitor all generator parameters, but it will also provide remote control of the excitation system set points.
page 11
MP-382 designed for marine applications. Shape and size customization.
BASLER DESIGNS CUSTOMIZED SOLUTIONS FOR:
OEM’sTurnkey contractorsSystem integratorsMarine specialistsPower plantsIndustryOil and gas applications
LOCAL PRESENCE GLOBAL REACH
Suzhou, P.R. ChinaTel.: +86 512 8227 [email protected]
Wasselonne, FranceTel.: +33 3 88 87 10 [email protected]
Highland, Illinois USAWorldwide Headquarters
Tel.: +1 618 654 [email protected]
SingaporeTel.: +65 68 44 6445
FOR MORE INFORMATION, CONTACT US OR VISIT OUR WEBSITE www.basler.com
Phot
os: C
opyr
ight
Bas
ler -
Shu
tters
tock
- Tac
het
BR
O_M
PD20
0_EN
_V2
Sept
embe
r 201