Dynaflow Lectures Reciprocating compressors
Acoustics and Mechanical Response
Rotterdam, December 10th 2009
-
8/12/2019 December 2009 vibration
2/57
2
EXAMPLECompressor piping vibration analysis
Two parts:
1. Acoustical/pulsation study
2. Mechanical response analysis
Labor intensive modeling
Large number of load cases.
Copyright 2009 Dynaflow Research Group BV
-
8/12/2019 December 2009 vibration
3/57
3
Sequence of dependence
Acoustics is about propagation of
pressure pulsations in piping systems
Source of Pressure pulsations:
Reciprocating compressors and pumps
Pressure waves are propagated thru the
piping system.
Pressure waves are reflected (partly) and
transmitted (partly) at geometrical
discontinuities
Pressure pulsations generate unbalancedforces that are the source of piping
vibration
Sustained vibration may result in fatigue
failures
Copyright 2009 Dynaflow Research Group BV
-
8/12/2019 December 2009 vibration
4/574
Elements of Acoustics
Aspects of Mechanical Response
Examples of Mechanical Response
Agenda
Copyright 2009 Dynaflow Research Group BV
-
8/12/2019 December 2009 vibration
5/57
Reciprocating compressors and pumps inherently
produce pulsations in the suction and discharge piping
5
Double acting cylinder:
Piston displacement opens and closes
suction and discharge valves
Copyright 2009 Dynaflow Research Group BV
-
8/12/2019 December 2009 vibration
6/57
Actual Piston movement (not purely sinusoidal) due to
finite rod length
Copyright 2009 Dynaflow Research Group BV 7
-
8/12/2019 December 2009 vibration
7/57
Valve openings result in a Sawtooth type of gas flowDue the sequence of piston movement and valve opening and closing
8
The shape of the sawtooth is determined by the rotational speed of thecompressor, the geometry of the cylinder and the pressure ratio.
Copyright 2009 Dynaflow Research Group BV
-
8/12/2019 December 2009 vibration
8/57
Flow time history for a single acting cylinderWith ideal instantaneous reacting valves
Copyright 2009 Dynaflow Research Group BV 9
-
8/12/2019 December 2009 vibration
9/57
Resulting Flow Frequency Spectrum (discrete) for single
acting cylinder
Copyright 2009 Dynaflow Research Group BV 10
-
8/12/2019 December 2009 vibration
10/57
Double acting cylinder (slightly unsymmetrical)Head end cranck end because of the piston rod volume
Copyright 2009 Dynaflow Research Group BV 12
-
8/12/2019 December 2009 vibration
11/57
-
8/12/2019 December 2009 vibration
12/57
Flow pulsations result in pressure pulsations
Pressure pulsations propagate thru the piping system at the speed of sound
Speed of sound depends on:
Gas composition
Gas Temperature
Gas Density
Pressure/Flow pulsations reflect at geometrical discont inuities
Wave length of propagating wave depending on speed of sound and pulsation frequency
Wave reflection and wave interaction results in system acoustical natural frequencies.e.g. for wave length/frequency that match a geometrical length scale standing waves may
occur
Presence of Acoust ical natural frequencies may result in Acoustical resonance
System wil l show an acoustical response to an acoust ical excitation
f
c=
Copyright 2009 Dynaflow Research Group BV 14
-
8/12/2019 December 2009 vibration
13/57
Example of acoustical natural frequency result
Copyright 2009 Dynaflow Research Group BV 15
-
8/12/2019 December 2009 vibration
14/57
Limited accuracy of acoustical model
Accuracy of prediction of acoustical natural frequencies relatively large
Error margin relatively small: +/- 5%
Errors controlled by limited number of parameters:
Geometry
Speed of sound
Compressor RPM
Copyright 2009 Dynaflow Research Group BV 16
-
8/12/2019 December 2009 vibration
15/57
Guidelines for acoustical pulsation levels according API618
Guidelines for acceptable pulsation levels.
Acceptable levels are related to (inversely proportional to) frequency, pipe
diameter and (proportional to) average pressure level
Measures to control pulsation levels:
Geometry changes (controlling acoustical natural frequencies)
Changing pipe diameters to reduce pulsation level
Introduction of damping (orifice plates at location of max oscillating flow)
Introduction of additional volumes with or without internals (creating filters)
Increasing size of bottles (windkessel function).
Copyright 2009 Dynaflow Research Group BV 17
-
8/12/2019 December 2009 vibration
16/57
-
8/12/2019 December 2009 vibration
17/57
19
EXAMPLEPulsation Bottles located near the compressor
Two bottles per
compressor
Multiple pistons per
compressor
Inlet scrubbers
COMPRESSORS
Copyright 2009 Dynaflow Research Group BV
-
8/12/2019 December 2009 vibration
18/57
Guidelines for Pulsation Bottle sizing
1. SINGLE CYLINDER BOTTLE 2. MULTICYLINDER BOTTLE
Copyright 2009 Dynaflow Research Group BV 20
-
8/12/2019 December 2009 vibration
19/57
Acoustical filters
Volumes connected by choke tubes
Filter frequency fh:
Filter frequency response
Copyright 2009 Dynaflow Research Group BV 21
-
8/12/2019 December 2009 vibration
20/57
22
Elements of Acoustics
Mechanical Response
Example of Mechanical Response
Agenda
Copyright 2009 Dynaflow Research Group BV
-
8/12/2019 December 2009 vibration
21/57
Mechanical response calculation fifth edition of API 618
Guidelines for pulsation levels.
If pulsation levels exceed guidelines system may be qualified by means of
mechanical response analysis.
Vibration control by mechanical means is a possible option
Large uncertainty margin in mechanics during design (minimum 10-20%)
Acoustic is more accurate (typically +/- 5%)
Preference for reduction of pulsations and thereby shaking forces by
means of acoustical measures e.g. filtering (e.g. Helmholtz resonator)
Copyright 2009 Dynaflow Research Group BV 23
-
8/12/2019 December 2009 vibration
22/57
Accuracy of prediction of mechanical natural frequenciesError margin: 10-20% or many time even larger
Modeling of Boundary conditions
Modeling of rack structures
Support clearance
Support lift off (thermal), support settling
Support stiffness i.e. stiffness of clamps and restraints
Influence of friction
Nonlinear supports (supports with gaps or single acting supports)
Uncertainties in masses
Differences between as built and design
Interaction between parallel pipes in pipe racks
Stiffness of concrete sleepers and pedestalsCopyright 2009 Dynaflow Research Group BV 24
-
8/12/2019 December 2009 vibration
23/57
Many vibration problems related to attached components
Examples:
Valve Actuators Small bore branch connections
Instrument connections
Level indicators
Stairs & Ladders
Copyright 2009 Dynaflow Research Group BV 25
-
8/12/2019 December 2009 vibration
24/57
Mechanical properties and pulsations
Rule of thumb: minimum mechanical natural frequency 20% above
second compressor harmonic. Question: is this feasible???
Copyright 2009 Dynaflow Research Group BV 26
-
8/12/2019 December 2009 vibration
25/57
Mechanical properties and pulsations (2)
Mechanical resonance difficult to avoid due to uncertainty in mechanical nat. freq..
Variable speed compressor makes separation virtually impossible.
At resonance condition amplitude limited by damping only (typical damping factors
of 2%-3% of critical)
High sti ffness results in lower amplitudes.
Copyright 2009 Dynaflow Research Group BV 27
-
8/12/2019 December 2009 vibration
26/57
Application of filters in combination with high
mechanical natural frequencies looks ideal
Copyright 2009 Dynaflow Research Group BV 28
-
8/12/2019 December 2009 vibration
27/57
29
Acoustics
Mechanical Response
Example of Mechanical Response analysis in design
Agenda
Copyright 2009 Dynaflow Research Group BV
-
8/12/2019 December 2009 vibration
28/57
EXAMPLE
30
Example: Mechanical Response of NAM Oude Pekela
Compressor plantAir cooler A-174
Copyright 2009 Dynaflow Research Group BV
-
8/12/2019 December 2009 vibration
29/57
Focal area
EXAMPLEAcoustical results of suction piping
31Copyright 2009 Dynaflow Research Group BV
-
8/12/2019 December 2009 vibration
30/57
Nodal correspondence:
3360-3430 = C2 node 1085
3350-3360 = C2 node 10703000-3350 = C2 node 1033
EXAMPLE
32
Unbalanced shaking forces in [kN peak to peak] per
pipe section and per compressor harmonic
Copyright 2009 Dynaflow Research Group BV
-
8/12/2019 December 2009 vibration
31/57
-
8/12/2019 December 2009 vibration
32/57
Nodal correspondence:3330-3340 = C2 node 5060
3340-3350 = C2 node 5076
3380-3350 = C2 node 5097
EXAMPLEUnbalanced shaking forces in [kN peak to peak] per
pipe section and per compressor harmonic
34Copyright 2009 Dynaflow Research Group BV
-
8/12/2019 December 2009 vibration
33/57
Summary of shaking forcesConservative selection: maximum value of all harmonics
Acoustic pipe
sectionCaesar II node number Force [N.] [peak-peak] Force [N.] [0-peak]
3330-3340 5060 131 65.5
3340-3350 5076 355 177.5
3350-3380 5097 815 407.5
3360-3430 1085 535 267.5
3350-3360 1070 240 120
3000-3350 1033 81 40.5
EXAMPLE
35Copyright 2009 Dynaflow Research Group BV
-
8/12/2019 December 2009 vibration
34/57
EXAMPLE
36
Two-stage compression combined modelSuction (partly), Interstage (upto cooler), Discharge (complete)
Aircooler E-174
nozzles
Suction LineDischarge Line
Additional discharge volumes
to reduce pulsation levels in
remaining piping
Compressor discharge bottles
Interstage Line
Copyright 2009 Dynaflow Research Group BV
-
8/12/2019 December 2009 vibration
35/57
Additional discharge volumesEXAMPLE
37Copyright 2009 Dynaflow Research Group BV
EXAMPLE
-
8/12/2019 December 2009 vibration
36/57
EXAMPLEHarmonic frequency assessment in CAESAR IISweep from 4 -56 Hz with 1 Hz steps
38Copyright 2009 Dynaflow Research Group BV
EXAMPLE
-
8/12/2019 December 2009 vibration
37/57
Harmonic forces are inserted in the modelConservative Shaking force set taken from acoustic pulsation report
EXAMPLE
39Copyright 2009 Dynaflow Research Group BV
EXAMPLE
-
8/12/2019 December 2009 vibration
38/57
EXAMPLEMaximum dynamic stress amplitude calculationMax amplitude 6 MPa
40Copyright 2009 Dynaflow Research Group BV
EXAMPLE
-
8/12/2019 December 2009 vibration
39/57
Carbon Steel Fatigue Curve in the high cycle range
EXAMPLEAt a stress amplitude level of 6 MPa the number of
cycles is > 1011
41
6 MPa
Copyright 2009 Dynaflow Research Group BV
A d
-
8/12/2019 December 2009 vibration
40/57
42
Acoustics
Mechanical Response
Example of Mechanical Response analysis as built
Agenda
Copyright 2009 Dynaflow Research Group BV
EXAMPLE
-
8/12/2019 December 2009 vibration
41/57
43
1. Vibration Measurements: identification of main contributions in frequency
domain
2. Acoustical Resonance: verification of acoustical natural frequencies
3. Mechanical Resonance: verification of mechanical natural frequencies
4. Identification of source of vibration problem
5. Modification proposal
EXAMPLEIssue: Unacceptably high vibration level in compressor
suction pipingIn 5 steps to solution
Copyright 2009 Dynaflow Research Group BV
C l t
-
8/12/2019 December 2009 vibration
42/57
Compressor plant
Copyright 2009 Dynaflow Research Group BV 44
Structure and support details around the compressor (I)
-
8/12/2019 December 2009 vibration
43/57
Structure and support details around the compressor (I)
Copyright 2009 Dynaflow Research Group BV45
St t d t d t il d th (II)
-
8/12/2019 December 2009 vibration
44/57
Structure and support details around the compressor (II)
Copyright 2009 Dynaflow Research Group BV46
D t il f th l ti
-
8/12/2019 December 2009 vibration
45/57
Details of the compressor location
Copyright 2009 Dynaflow Research Group BV47
EXAMPLEStep 1 Vibration Measurements
-
8/12/2019 December 2009 vibration
46/57
48
0.00
20.00
40.00
60.00
80.00
100.00
120.00
0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.
Frequency (Hz)
Amplitude(dB)
66 Hz49 Hz
33 Hz
16 Hz
99 Hz
83 Hz
Step 1. Vibration Measurements
Copyright 2009 Dynaflow Research Group BV
Intermediate conclusion from step 1
-
8/12/2019 December 2009 vibration
47/57
Intermediate conclusion from step 1
Vibrations are at compressor harmonics
Vibrations must be result of
Acoustical resonance
or
Mechanical resonance
or
High pulsation forces without resonance (compressor bottle sizing
problem)
49Copyright 2009 Dynaflow Research Group BV
1
2
3
EXAMPLEStep 2 Acoustical natural frequencies & Compressor
-
8/12/2019 December 2009 vibration
48/57
50
0
50
100
150
200
250
10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00
Frequency (Hz)
Am
plitude
16 Hz
Step 2. Acoustical natural frequencies & Compressor
Harmonics
Copyright 2009 Dynaflow Research Group BV
EXAMPLEIntermediate conclusion from step 2
-
8/12/2019 December 2009 vibration
49/57
51
Maybe near-to-resonance condition at first compressor harmonic (16.5 Hz.)
No further acoustical resonance
Vibration peak at 16.5 Hz, most probably is due high shaking forces as a
result of near resonant condition
The other vibration peaks must be the result of:
Mechanical resonance
or
High pulsation forces without resonance (compressor bottle sizing
problem)
Intermediate conclusion from step 2
1
2
Copyright 2009 Dynaflow Research Group BV
EXAMPLE
Step 3 Vibration Measurements & Calculated Mechanical
-
8/12/2019 December 2009 vibration
50/57
52
0.00
10.00
20.00
30.00
40.00
50.00
60.00
70.00
80.00
90.00
100.00
0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0
Frequency (Hz)
Amplitude(dB)
66 Hz
33 Hz83 Hz
Step 3. Vibration Measurements & Calculated Mechanical
Natural Frequencies (Search for Mechanical Resonance)
Purple vertical lines represent pipe system natural frequencies
Copyright 2009 Dynaflow Research Group BV
Conclusion from step 3 & Identification of cause of
-
8/12/2019 December 2009 vibration
51/57
Conclusion from step 3 & Identification of cause of
vibration problem
Apparently there is mechanical resonance at 33 Hz and 66 Hz and nearmechanical resonance at 83 Hz
No mechanical resonance condition at the first compressor harmonic(16.5 Hz.) and at 49 Hz. and 99 Hz
The high vibration levels 33 Hz, 66 Hz and 83 Hz are of mechanical
nature
The high vibration level at 16.5 Hz most probably is an acousticalresonance problem
The high vibration level at 49 Hz and 99 Hz. must be the result of Highpulsation forces without resonance (compressor bottle sizing problem)
53Copyright 2009 Dynaflow Research Group BV
EXAMPLEStep 4. Identification of cause of vibration problem
-
8/12/2019 December 2009 vibration
52/57
54
The high vibration level at 16.5 Hz most probably is an acousticalresonance problem.
Apparently there is mechanical resonance at 33 Hz and 66 Hz and nearmechanical resonance at 83 Hz.
The high vibration levels 33 Hz, 66 Hz and 83 Hz are of mechanical nature
No mechanical resonance condition at the first compressor harmonic (16.5Hz.) and at 49 Hz. and 99 Hz.
The high vibration level at 49 Hz and 99 Hz. must be the result of: High pulsation forces without resonance (compressor bottle sizing
problem)
Step 4. Identification of cause of vibration problem
Copyright 2009 Dynaflow Research Group BV
EXAMPLEExamination of mechanical behavior
-
8/12/2019 December 2009 vibration
53/57
55
Large amplitude movement
in suction manifold
Example of 66 Hz. mode shape
Copyright 2009 Dynaflow Research Group BV
EXAMPLEStep 5. Modifications
-
8/12/2019 December 2009 vibration
54/57
56
1. The high vibration levels 33 Hz, 66 Hz and 83 Hz are of mechanical nature
and need a mechanical solution
Better supporting Improved support stiffness
2. The high vibration level at 16.5 Hz is due to acoustical resonance and
needs an acoustical solution, I.e. different bottles and/or orifice plates tointroduce more damping
3. The high vibration level at 49 Hz and 99 Hz. are the result of high pulsation
forces without resonance and must be resolved by compressor bottle(re)sizing.
p
Copyright 2009 Dynaflow Research Group BV
EXAMPLEModified structure implemented and connected to
-
8/12/2019 December 2009 vibration
55/57
57
p
attached piping
AS BUILT SITUATION IMPROVED AND IMPLEMENTED SITUATION
Copyright 2009 Dynaflow Research Group BV
EXAMPLEConclusion from example
-
8/12/2019 December 2009 vibration
56/57
58
Compressor vibration problems many cases are of a mixed nature
Part is mechanical
Part is acoustical
Each category requires a different approach and result in differentsolutions
Not all vibration problems can be solved by mechanical measures.
Copyright 2009 Dynaflow Research Group BV
-
8/12/2019 December 2009 vibration
57/57
END