UP
LOT DIMENSION200' - 0"
200' - 0"
BIULDING DIMENSION TO REMAIN± 50' - 4"
2A0.0
ALLEY± 7' - 0"
BUILDING DIMENSION TO BE DEMOLISHED± 100' - 0"
SINGLE STORY PORTION OF BUILDING
TO BE DEMOLISHED THREE STORY PORTION OF BUILDING TO BE
DEMOLISHED
TWO STORY PORTION OF
BUILDING TO BE DEMOLISHED
EXISTING EXTERIOR STAIRS, RAILING AND LANDING TO BE DEMOLISHED
DEMOLISH DAMAGED GARDEN WALL AT ALLEY
SINGLE STORY BUILDING TO REMAIN
ASPHALT PARKING TO BE REPAIRED AS
NECESSARY
AREA OF CMU RETAINING WALL TO BE REPAIRED IN KIND
IRON FENCE TO REMAIN
IRON FENCE AND GATES TO REMAIN42" BRICK RETAINING
WALLS TO REMAIN
42" BRICK RETAINING WALLS TO REMAIN
N BROAD ST LEGALLY OPEN ON
CITY PLANS113' RIGHT OF WAY
[22-69-22]
FENCE± 4' - 4"
FEN
CE
46' -
4"
N CARLISLE ST LEGALLY OPEN ON
CITY PLANS40' RIGHT OF WAY
[10-20-10]
1512-16 N BROAD ST EXISTING THREE STORY PLACE OF WORHSHIP AND
ADJACENT SURFACE PARKING. PROPOSED DEMOLITION AND NEW WORK TO SECURE
AND MAKE SAFE THE FRONT PORTION OF THE HISTORICALLY DESIGNATED BUILDING
75' -
0"
1518 N BROAD ST EXISTING ADJACENT VACANT LOT
1500-10 N BROAD ST DEVELOPED LOT WITH EXISTING
DETACHED BUILDINGS
THREE STORY PORTION OF BUILDING TO REMAIN
LOCATION MAP
2637 AMBER ST
ZONING: CMX-4LOT AREA: 15000.00 SF (0.344 ACRE)
USE: PLACE OF WORSHIP (NO CHANGE)
FOR THE DEMOLITION OF PORTION OF A HISTORICALLY DESIGNATED PLACE OF WORSHIP. REAR RED BRICK PORTION TO BE DEMOLISHED TO THE FOUNDATION WALLS AND SLAB. FOUNDATIONS TO BE RETAINED, NEW WORK WILL ONLY BE TO SECURE, STABILIZE AND WATERPROOF THE REMAINING FRONT PORTION OF THE BUILDING.
NEW WORK TO INCLUDE TEMPORARY SAFETY BARRIERS, RAILINGS, AND CROSS BRACING PER STRUCTURAL PLANS. WINDOWS AND OPENINGS TO BE INFILLED, CORNICE TO BE REPAIRED, AND REAR WALL TO BE CONSTRUCTED PER ARCHITECTURAL PLANS.
PROJECT SUMMARY: 1512 N BROAD ST
#
DRAWING TITLE
WINDOW TAG
SECTION TAG
ELEVATION TAG
DOOR TAG
KEYED NOTE
# ###
#
SMOKE DETECTOR
CARBON MONOXIDE DETECTOR
PARTITION TYPE
ELEVATION TAG
REVISION TAG
ENLARGED DETAIL TAG
RATED PARTITION
EXISTING PARTITION
NON RATED PARTITION
PARTIAL HEIGHT PARTITION
SD
CMD
DATUMHEIGHT
1
#A#
SYMBOLS LEGEND
#A#
#A#
#A#
#
FINISH DIMENSION
CENTER LINE DIMENSION
THIRD FLOOR32' - 9"
ROOF50' - 9"
SECOND FLOOR18' - 9"
FIRST FLOOR9"
AREA OF DEMOLITION
AREA TO REMAIN
AREA TO REMAIN
NOT FOR
CONSTRUCTIO
N
DEM
O &
MAKE-
SAFE
1512
N B
ROAD S
TPH
ILADEL
PHIA
, PA
1912
2CO
VER
SHEE
TA
0.0
DEMO & MAKE-SAFE1512 N BROAD ST
PHILADELPHIA, PA 19122
1/8" = 1'-0"A0.01 ZONING PLAN
1" = 20'-0"A0.02 ZONING ELEVATION
1HIS
TORI C
AL
COMM
IS SION
07/08
/2 019
NOT FOR
CONSTRUCTIO
N
DEM
O &
MAKE-
SAFE
1512
N B
ROAD S
TPH
ILADEL
PHIA
, PA
1912
2PH
OTO
GRA
PHS
A0
.1
VIEW ON BROAD ST LOOKING NORTH VIEW ON BROAD ST LOOKING WEST VIEW ON BROAD ST LOOKING SOUTH
VIEW FROM PARKING LOT LOOKING SOUTH(FRONT PORTION)
VIEW FROM PARKING LOT LOOKING SOUTH(MIDDLE PORTION)
VIEW FROM PARKING LOT LOOKING SOUTH(MIDDLE PORTION PORTION)
VIEW FROM PARKING LOT LOOKING SOUTH(REAR PORTION)
AREA OF DEMOAREA OF DEMO
AREA OF DEMO
AREA OF DEMO
1HIS
TORI C
AL
COMM
IS SION
07/08
/2 019
124567 3
1A2.1
1A2.0
1A2.2
3A2.1
DEMOLISH REAR BRICK WALL
DEMOLISH ALL STEEL STRUCTURAL MEMBERS
DEMOLISH ALL EXTERIOR RED BRICK WALLS, RETAIN FOUNDATION WALLS
RETAIN EXISTING STUCCO WALLS
DEMOLISH ALL EXTERIOR RED BRICK WALLS
DEMOLISH EXTERIOR STEEL STAIR, RAILING AND LANDING
DEMOLISH EXISTING GARDEN WALL AT ALLEY
DEMOLISH ALL WOOD FRAMED FLOORS RETAIN ALL WOOD FRAMED FLOORS AND ROOF
TO REMAIN50' - 4" FRONT PORTION
REMOVE CAST STONE PIECES FOR RESTORATION PER ELEVATION
REAR BUILDING TO REMAIN
N BROAD ST
124567 3
2A2.1
1A2.0
2A2.2
4A2.1
1/4"
/ 12
"
N BROAD ST
NEW TEMPORARY ROOF ASSEMBLY
4" DRAIN TIED TO SEWER 4" DRAIN TIED TO SEWER
42" PARAPET WALL
NEW TEMPORARY EXTERIOR WALL PER PARTITION TYPES
RETAIN AND REPAIR EXISTING WOOD FRAMED
FLOORS, STAIRS AND ROOF
CRICKET SLOPE:1/2" / 12" (TYP)
REAR BUILDING TO REMAIN [3] 2x12 BEAM, DROPPED
2x6 @ 16" O.C. BEARING WALL
2x12 LEDGER AT FOUNDATION WALL
2x12
JO
ISTS
@
16"
O.C
.2x
12 J
OIS
TS
@ 1
6" O
.C.
NOT FOR
CONSTRUCTIO
N
DEM
O &
MAKE-
SAFE
1512
N B
ROAD S
TPH
ILADEL
PHIA
, PA
1912
2DEM
O A
ND
NEW
WO
RKPL
ANS
A1.
1
1/8" = 1'-0"A1.11 04 - ROOF DEMO
1/8" = 1'-0"A1.12 ROOF PLAN
1HIS
TORI C
AL
COMM
IS SION
07/08
/2 019
4A2.1
123
1A2.1
1A2.0
1A2.2
A3.04
Sim
[2] 2x10 CROSS BRACE, EACH FLOOR
NEW 2x6 EXTERIOR WALL
4A2.1
123
A3.04
2A2.1
2A2.0
2A2.2
[2] 2x10 CROSS BRACE, EACH FLOOR
NEW 2x6 EXTERIOR WALL
4A2.1
123
3A3.0
1A2.1
1A2.0
1A2.2
A1.12
Sim
[2] 2x10 CROSS BRACE, EACH FLOOR
NEW 2x6 EXTERIOR WALL
4A2.1
123
2A3.0
1A2.1
1A2.0
1A2.2
RETAIN EXISTING PITCH
CRICKET PITCH 1/2" / 12" TYP
4" DRAIN TIED DIRECTLY TO SEWER
NEW EXTERIOR WALL PER PARTITION TYPES
PREVIOUSLY REMOVED LINTEL STONES TO BE REPLACED
NEW EPDM ROOFING
NOT FOR
CONSTRUCTIO
N
DEM
O &
MAKE-
SAFE
1512
N B
ROAD S
TPH
ILADEL
PHIA
, PA
1912
2FL
OO
RPL
ANS
A1.
01
1/4" = 1'-0"A1.011 FIRST FLOOR PLAN
1/4" = 1'-0"A1.012 SECOND FLOOR PLAN
1/4" = 1'-0"A1.013 THIRD FLOOR PLAN
1/4" = 1'-0"A1.014 ROOF PLAN
1HIS
TORI C
AL
COMM
IS SION
07/08
/2 019
THIRD FLOOR32' - 9"
ROOF50' - 9"
GRADE0"
PARAPET52' - 3"
SECOND FLOOR18' - 9"
FIRST FLOOR9"
REMOVE EXISTING PLYWOOD CORNICE
RETAIN ALL EXISTING WINDOW FRAMES, SASHES AND MUNTINS. REMOVE BROKEN GLASS AS NECESSARY.
REMOVE TOP TWO COURSES OF CAST STONE MASONRY, CLEAN OF ALL MORTAR AND DEBRIS. SALVAGED PIECES TO BE RETAINED FOR RECONSTRUCTION
LIMESTONE LEDGES AND FIGURES TO REMAIN
THIRD FLOOR32' - 9"
ROOF50' - 9"
GRADE0"
SECOND FLOOR18' - 9"
FIRST FLOOR9"
A2.04
2A3.0
3A3.0
REBUILD TOP TWO COURSES OF LIMESTONE AND REPLACE PREVIOUSLY REMOVED, SALVAGED CORNICE PIECES
INFILL WINDOW OPENINGS BEHIND EXISTING WINDOWS WITH EXTERIOR WALL PER PARTITION TYPES(WINDOWS TO BE RESTORED IN THE SECOND PHASE OF CONSTRUCTION)
FIRST FLOOR WINDOWS TO REMAIN, INFILL BEHIND EXSTING WINDOWS PER DETAIL 3/A3.0
2A3.0
PREVIOUSLY DISMANTLED/SALVAGED CORNICE PIECES REBUILT
DISMANTLE AND REBUILD TOP TWO COURSES OF LIMESTONE
LIMESTONE FACADE TO REMAIN
ROOF50' - 9"
1DISMANTLE AND REBUILD TOP TWO COURSES OF LIMESTONE
DISMANTLE AND REBUILD TOP COURSES OF BRICK AS REQUIRED
PREVIOUSLY DISMANTLED/SALVAGED CORNICE PIECES REBUILT
ROOF50' - 9"
1DISMANTLE AND REBUILD TOP
TWO COURSES OF LIMESTONE
NEW LIMESTONE PIECE TO MATCH EXISTING
PREVIOUSLY DISMANTLED/SALVAGED CORNICE PIECES REBUILT
NOT FOR
CONSTRUCTIO
N
DEM
O &
MAKE-
SAFE
1512
N B
ROAD S
TPH
ILADEL
PHIA
, PA
1912
2FR
ONT
ELEV
ATI
ONS
A2
.0
1/4" = 1'-0"A2.01 FRONT ELEVATION
1/4" = 1'-0"A2.02 NEW WORK FRONT ELEVATION
1/2" = 1'-0"A2.04 DETAIL AT FRONT ELEVATION CORNICE
1/2" = 1'-0"A2.03 DETAIL AT SOUTH ELEVATION CORNICE
1/2" = 1'-0"A2.05 DETAIL AT NORTH ELEVATION CORNICE
2 2
2
1HIS
TORI C
AL
COMM
IS SION
07/08
/2 019
2HS
ITORI C
AL R
EVISI
ONS
07/23
/2 019
3CO
MMI TT
EE RE
VISION
S07
/25/2 0
19
3
3
3
3
THIRD FLOOR32' - 9"
ROOF50' - 9"
GRADE0"
PARAPET52' - 3"
SECOND FLOOR18' - 9"
FIRST FLOOR9"
1 2 4 5 6 73REMOVE PLYWOOD CORNICE
PORTION TO BE DEMOLISHED (REFER TO A1.1)± 107' - 0"
STUCCO WALL TO REMAINRED BRICK AND STEEL REAR PORTION TO BE DEMOLISHED
REAR BRCIK BUILDING TO REMAIN
THIRD FLOOR32' - 9"
ROOF50' - 9"
GRADE0"
PARAPET52' - 3"
SECOND FLOOR18' - 9"
FIRST FLOOR9"
1 2 4 5 6 73A2.0
5
STUCCO WALL TO REMAINREAR WALL TO BE ENCLOSED PER NEW PARTITION TYPE
NEW TEMPORARY ROOF ASSEMBLY
NEW TEMPORARY PARAPET ASSEMBLY
REAR BRCIK BUILDING TO REMAIN
REPAIR TERRACOTTA CORNICE IN-KIND
THIRD FLOOR32' - 9"
ROOF50' - 9"
GRADE0"
SECOND FLOOR18' - 9"
FIRST FLOOR9"
1REMOVE PLYWOOD CORNICE
DISMANTLE TOP TWO COURSES OF LIMESTONE
THIRD FLOOR32' - 9"
ROOF50' - 9"
GRADE0"
PARAPET52' - 3"
SECOND FLOOR18' - 9"
FIRST FLOOR9"
1A2.0
3
REBUILD TOP TWO COURSES OF LIMESTONE
NOT FOR
CONSTRUCTIO
N
DEM
O &
MAKE-
SAFE
1512
N B
ROAD S
TPH
ILADEL
PHIA
, PA
1912
2SI
DE
ELEV
ATI
ONS
A2
.1
1/8" = 1'-0"A2.11 DEMO NORTH ELEVATION
1/8" = 1'-0"A2.12 NEW WORK NORTH ELEVATION
1/8" = 1'-0"A2.13 DEMO SOUTH ELEVATION
1/8" = 1'-0"A2.14 NEW WORK SOUTH ELEVATION
1HIS
TORI C
AL
COMM
IS SION
07/08
/2 019
THIRD FLOOR32' - 9"
ROOF50' - 9"
GRADE0"
PARAPET52' - 3"
SECOND FLOOR18' - 9"
FIRST FLOOR9"9"
18' -
0"
NEW WALLEXTERIOR WALL ASSEMBLY PER PARTITION TYPES
EXISTING ROOF TO REMAIN
[2] 2x10 CROSS BRACING
[2] 2x10 CROSS BRACING
[2] 2x10 CROSS BRACING
[2] 2x10 CROSS BRACING
[2] 2x10 CROSS BRACING
[2] 2x10 CROSS BRACING
TEMPORARY ROOF ASSEMBLY
TEMPORARY 2x6 BEARING WALL
TEMPORARY PARAPET WALL
ALUM FLASHING OVER ICE AND WATER SHIELD
A3.01
THIRD FLOOR32' - 9"
ROOF50' - 9"
GRADE0"
PARAPET52' - 3"
SECOND FLOOR18' - 9"
FIRST FLOOR9"
DEMOLISH REAR WALL
DEMOLISH REAR PORTION PER SIDE ELEVATIONS
NOT FOR
CONSTRUCTIO
N
DEM
O &
MAKE-
SAFE
1512
N B
ROAD S
TPH
ILADEL
PHIA
, PA
1912
2RE
AR
ELEV
ATI
ONS
A2
.2
1/4" = 1'-0"A2.22 NEW WORK REAR ELEVATION
1/4" = 1'-0"A2.21 DEMO REAR ELEVATION
1HIS
TORI C
AL
COMM
IS SION
07/08
/2 019
ROOF50' - 9"
1
PREVIOUSLY DISMANTLED CORNICE LIMESTONE TO BE CLEANED OF ALL MORTAR AND DEBRIS AND REPLACED
DISMANTLE TOP TWO COURSES OF LIMESTONE, TO BE CLEANED OF ALL MORTAR AND DEBRIS AND REBUILT PER CURRENT BUILDING CODES
EXISTING LIMESTONE FACADE TO REMAIN
NEW GALVANIZED CORRUGATED BRICK TIES AT EACH JOINT AND AT 16" O.C. HORIZONTALLY
EXISTING MASONRY BACKER WALL TO REMAIN
1
2x8'S @ 16" O.C.PRESSURE TREATED WHEN IN CONTACT WITH MASONRY
ALUMINUM FLASHING WITH HEMMED EDGE
BUILDING WRAP LAPPED OVER TOP OF FLASHING
1/4" MASONRY ANCHORS AT SIDES OF OPENINGS
6"TY
P1'
- 4"
EXISTING LINTELS AND MASONRY WALL TO REMAIN
EXISTING LINTELS AND MASONRY WALL TO REMAIN
ALUM FLASHING WITH HEMMED EDGE
RETAIN EXISTING WINDOW FRAMES, SASHES AND MUNTINS, REMOVE BROKEN GLASS
FLASHING TO COVER BOTTOM OF WINDOW SILL
TEMPORARY BLOCKING FOR FLASHING
3
EXISTING MASONRY WALL WITH STUCCO FINISH
EXTERIOR WALL ASSEMBLY
1/2" BOLTS @ 16" O.C. EPOXY ANCHORED INTO EXISTING ,MASONRY WALL WITH 6" MIN EMBED
[2] P/T 2x6 POST
EXTEND FINISH TO OUTSIDE FACE OF BRICK
PARTITION TYPES2x6 WD EXTERIOR WALL W/ FIBERCEMENT LAP SIDING
2x6 BASE PLATE (P/T/ WHEN IN CONTACT W/ CONCRETE)
2x6 STUDS @ 16" O.C.
1/2" PLYWOOD SHEATHING
CONTINUOUS AIR/WATER BARRIER
FIBER CEMENT LAP SIDING
DOUBLE 2x6 TOP PLATE
2x6 STUDS @ 16" O.C.
HORIZONTAL ASSEMBLY TYPES
EXISTING JOIST TO REMAIN
EXISTING DECKING TO REMAIN
NEW REFLECTIVE EPDM ROOFING
EXISTING ROOF ASSEMBLY
NEW WOOD JOISTS PER STRUCTURAL
3/4" PLYWOOD DECKING(PROVIDE FLAME RETARDANT PLYWOOD PER PLANS)
TEMPORARY NEW ROOF ASSEMBLY
REFLECTIVE EPDM ROOFING
1/2" BOLTS @ 16" O.C. EPOXY ANCHORED INTO EXISTING ,MASONRY WALL WITH 6" MIN EMBED
PT BASE PLATE
ALUM FLASHING WITH HEMMED EDGE
LAP BUILDING WRAP OVER FLASHING
LAP ROOFING OVER CANT STRIP AND UP PARAPET WALL 12"
LAP BUILDING WRAP OVER ROOFING
ALUM FLASHING WITH HEMMED EDGE
ICE AND WATER SHIELD
PROVIDE EXTERIOR WALL ASSEMBLY BOTH SIDES AT PARAPET
NOT FOR
CONSTRUCTIO
N
DEM
O &
MAKE-
SAFE
1512
N B
ROAD S
TPH
ILADEL
PHIA
, PA
1912
2DET
AIL
SA
3.0
1 1/2" = 1'-0"A3.02 DETAIL AT CORNICE
1 1/2" = 1'-0"A3.03 DETAIL AT WINDOW INFILL
1 1/2" = 1'-0"A3.04 PLAN DETAIL AT REAR WALL
1 1/2" = 1'-0"A3.01 DETAIL AT TEMPORARY PARAPET
2
1HIS
TORI C
AL
COMM
IS SION
07/08
/2 019
2HS
ITORI C
AL R
EVISI
ONS
07/23
/2 019
3CO
MMI TT
EE RE
VISION
S07
/25/2 0
19
3