Download - Cse & WTe 630 - Aermec
Cse & WTe 630FlaT bed uniT1 or 2 roW oF Fans
air cooLed condensed Unit | drY cooLer Unit
AIR CONDENSERS AND lIquID COOlERS wITH AxIAl fANS• Configuration: 1 or 2 exchangers• 1 or 2 indipendent circuits• 1 or 2 fans row• Wide range of capacity• 108 models available as condenser• 108 models available as dry coolers• Fan diameter: 630 mm• Vertical for the single row of fan or horizontal intallation for single row or double row
CONSTRuCTION CHARACTERISTICSThey are realized with technologies and material which guarantee strength against atmospheric agents.High efficiency finned block heat exchangers realized with copper tubes and alluminium fins. New generation axial fans with 630 mm diameter available in version AC. Standard unit are supplied with cabled fans and electrical box with clamps.
AVAIlAblE fANSBTD: 6-poles with delta connectionBTY: 6-poles with star connectionSTD: 8-poles with delta connectionSTY: 8-poles with star connectionETD: 12-poles with delta connectionETY: 12-poles with star connection
ACCESSORIESCSE and WTE units could be equipped with main switch, switchboard, cut phase fan speed regulator (with 1 set point or 2 set point) or inverter with shielded cables and temperature sensor, pressure sensor or 0-10V signal.All fan motors could be equipped with switch for each motor. Anti-vibration device are also available for reducing machine’s vibrations and only for dry coolers flanges in oreder to simplify hydraulic connection.
Models
Model
Main switch
Switch for each motor
Switchboard
Phase cut regulatori
Probe
Anti-vibration
device
CSE-WTE BTD p p p p p p
CSE-WTE BTY p p p p p p
CSE-WTE STD p p p p p p
CSE-WTE STY p p p p p p
CSE-WTE ETD p p p p p
CSE-WTE ETY p p p p p p
Cse condenser and WTe dry cooler’s serie meet equipment’s power requirements.They are available from 1 up to 8 fans both version aC
CApACITYIn air condenser unit power range with refrigerant R134a is from 4.3 up to 87.9 tons (ambient air temperature +77°F, average condensing temperature +104°F according to EN 327)
In air condenseer unit power range with refrigerant R410A is from 4.8 up to 101.2 tons (ambient air temperature +77°F, average condensing temperature +104°F according to EN 327)
In dry cooler unit power range with ethylene glycol 30% is from 3.6 up to 80.2 tons (ambient air temperature +77°F, inlet liquid temperature +104°F outlet liquid temperature +95°F according to EN 1048)
eChniCal draWinG
Quota a
- CSE/WTE° 601(3/4)
- CSE/WTE° 602(3/4)
- CSE/WTE° 603(3/4)
- CSE/WTE° 604(3/4)
- CSE/WTE° 606(3/4)
- CSE/WTE° 608(3/4)
10 50 90 130
170
210
250
290
330
ETY
ETD
STY
STD
BTY
BTD
kW (T.air 25°C - T.cond 40°C)
CSE 630 R134a
10 50 90 130
170
210
250
290
330
370
ETY
ETD
STY
STD
BTY
BTD
kW (T.air 25°C - T.cond 40°C)
CSE 630 R410A
10 50 90 130
170
210
250
290
ETY
ETD
STY
STD
BTY
BTD
kW (T.air 25°C - T.liq 40/35°C)
WTE 630
47.6 (single row of fans)
93.3 (single row of fans)
139 (single row of fans)
184.6 (single row of fans)
139 (double row of fans)
184.6 (double row of fans)
Quota A
47.2 in
Quota A
40.7in
81.3 in
39.5 in
38.2 in
AERMECAddress: 1608 Bonhill Road. Mississauga, Ontario, CA L5T 1C7 Website: www.aermec.usEmail: [email protected]: 1-800-567-2221US: 1-888-567-2227