WARMUP TOTAL16. Concrete subfloor. Generic template
01_ Subfloor to SR1 standard
02_ Warmup Glue [WHS-S-GLUE]*
03_ Warmup Total-16 Panel
04_ Warmup 12mm pipework
05_ Warmup Primer [WHS-X-PRIMER]
06_ Warmup 12 mm Leveling Compound [WHS-X-PRIMER]
07_ Floor finish and intermediate layer
03_ Warmup Perimeter expansion strip or 10 mm expansion gap
REV DATE DESCRIPTION DR CH
DRAWING ISSUE STATUS
PROJECT
PROJECT MANAGER DRAWN CHECKED
DATE SCALE REVISION
© This drawing is confidential and may not be used, copied ordisclosed to anyone without permission of Warmup Plc. The Copyrightof these drawings remain the property of Warmup Plc.
Do not scale from drawings, all dimensions to be checked on site.
The Warmup word and associated logos are trade marks. © WarmupPlc. 2010 - Regd. TM Nos. 1257757, 4409926, 5265707. E & OE. Registeredin England No. 2955213.
DRAWING NO
CAD FILE
WARMUP PLC, 704 Tudor Estate, Abbey Road, London,NW10 7UW Tel 0845 034 8270 Fax 0208 453 6869
[email protected] [email protected] www.warmup.co.uk
TITLE
DETAILED SECTION
CONSTRUCTION 01
TOTAL-16 LOW PROFILE SYSTEMCONCRETE SUBFLOOR
GENERIC TEMPLATE
21.12.2016
20161215-H-T16-DET SECTIONS.DWG
AA
1:50@A3
AW
WARMUP TOTAL16. Concrete subfloor. Tiled floor - Domestic Installation
01_ Subfloor to SR1 standard
02_ Warmup Glue [WHS-S-GLUE]*
04_ Warmup Total-16 Panel
05_ Warmup 12mm pipework
06_ Warmup Primer [WHS-X-PRIMER]
07_ Warmup Adhesive [WHS-X-SEAL25]
08_ Tiled floor finish
* If rising damp is an issue use Warmup Adhesive (WHS-X-SEAL25) mixed with binder(WHS-X-BINDER) to adhere the boards to the subfloor. Do not use Warmup Glue (WHS-X-GLUE).
03_ Warmup perimeter expansion strip or 10 mm expansion gap
REV DATE DESCRIPTION DR CH
DRAWING ISSUE STATUS
PROJECT
PROJECT MANAGER DRAWN CHECKED
DATE SCALE REVISION
© This drawing is confidential and may not be used, copied ordisclosed to anyone without permission of Warmup Plc. The Copyrightof these drawings remain the property of Warmup Plc.
Do not scale from drawings, all dimensions to be checked on site.
The Warmup word and associated logos are trade marks. © WarmupPlc. 2010 - Regd. TM Nos. 1257757, 4409926, 5265707. E & OE. Registeredin England No. 2955213.
DRAWING NO
CAD FILE
WARMUP PLC, 704 Tudor Estate, Abbey Road, London,NW10 7UW Tel 0845 034 8270 Fax 0208 453 6869
[email protected] [email protected] www.warmup.co.uk
TITLE
DETAILED SECTION
CONSTRUCTION 02
TOTAL-16 LOW PROFILE SYSTEMCONCRETE SUBFLOOR
TILED FLOOR. DOMESTIC INSTALLATION
21.12.2016
20161215-H-T16-DET SECTIONS.DWG
AA
1:50@A3
AW
WARMUP TOTAL16. Concrete subfloor. Tiled floor - Light Commercial Installation* If rising damp is an issue use Warmup Adhesive (WHS-X-SEAL25) mixed with binder
(WHS-X-BINDER) to adhere the boards to the subfloor. Do not use Warmup Glue (WHS-X-GLUE).
01_ Subfloor to SR1 standard
02_ Warmup Glue [WHS-X-GLUE]*
04_ Warmup Total-16 Panel
05_ Warmup 12mm pipework
06_ Warmup Primer [WHS-X-PRIMER]
07_ Warmup Adhesive [WHS-X-SEAL25] mixed with blinder [WHS-X-BINDER]
10_ Tiled floor finish
03_ Warmup perimeter expansion strip or 10 mm expansion gap
08_ Warmup Dual Overlay Concrete
09_ Flexible tile adhesive
REV DATE DESCRIPTION DR CH
DRAWING ISSUE STATUS
PROJECT
PROJECT MANAGER DRAWN CHECKED
DATE SCALE REVISION
© This drawing is confidential and may not be used, copied ordisclosed to anyone without permission of Warmup Plc. The Copyrightof these drawings remain the property of Warmup Plc.
Do not scale from drawings, all dimensions to be checked on site.
The Warmup word and associated logos are trade marks. © WarmupPlc. 2010 - Regd. TM Nos. 1257757, 4409926, 5265707. E & OE. Registeredin England No. 2955213.
DRAWING NO
CAD FILE
WARMUP PLC, 704 Tudor Estate, Abbey Road, London,NW10 7UW Tel 0845 034 8270 Fax 0208 453 6869
[email protected] [email protected] www.warmup.co.uk
TITLE
DETAILED SECTION
CONSTRUCTION 03
TOTAL-16 LOW PROFILE SYSTEMCONCRETE SUBFLOOR
TILED FLOOR. LIGHT COMMERCIAL INST.
21.12.2016
20161215-H-T16-DET SECTIONS.DWG
AA
1:50@A3
AW
WARMUP TOTAL16. Concrete subfloor. 14-25 mm Wood / Laminate floor - floating
01_ Subfloor to SR1 standard
02_ Warmup perimeter expansion strip or 10 mm expansion gap
03_ Warmup Total-16 Panel
04_ Warmup 12mm pipework
05_ UFH compatible underlay
06_ Floating timber floor finish
REV DATE DESCRIPTION DR CH
DRAWING ISSUE STATUS
PROJECT
PROJECT MANAGER DRAWN CHECKED
DATE SCALE REVISION
© This drawing is confidential and may not be used, copied ordisclosed to anyone without permission of Warmup Plc. The Copyrightof these drawings remain the property of Warmup Plc.
Do not scale from drawings, all dimensions to be checked on site.
The Warmup word and associated logos are trade marks. © WarmupPlc. 2010 - Regd. TM Nos. 1257757, 4409926, 5265707. E & OE. Registeredin England No. 2955213.
DRAWING NO
CAD FILE
WARMUP PLC, 704 Tudor Estate, Abbey Road, London,NW10 7UW Tel 0845 034 8270 Fax 0208 453 6869
[email protected] [email protected] www.warmup.co.uk
TITLE
DETAILED SECTION
CONSTRUCTION 04
TOTAL-16 LOW PROFILE SYSTEMCONCRETE SUBFLOOR
25mm WOOD/LAMINATE FLOOR-FLOATING
21.12.2016
20161215-H-T16-DET SECTIONS.DWG
AA
1:50@A3
AW
07_ UFH compatible underlay
08_ Floating timber floor finish
06_ Warmup Dual Overlay Concrete or 18 mm T&G P5 Chipboard floor
WARMUP TOTAL16. Concrete subfloor. <14 mm Wood / Laminate floor - floating
01_ Subfloor to SR1 standard
02_ Warmup perimeter expansion strip or 10 mm expansion gap
03_ Warmup Total-16 Panel
04_ Warmup 12mm pipework
05_ 1 mm Polyethylene foam or equivalent
REV DATE DESCRIPTION DR CH
DRAWING ISSUE STATUS
PROJECT
PROJECT MANAGER DRAWN CHECKED
DATE SCALE REVISION
© This drawing is confidential and may not be used, copied ordisclosed to anyone without permission of Warmup Plc. The Copyrightof these drawings remain the property of Warmup Plc.
Do not scale from drawings, all dimensions to be checked on site.
The Warmup word and associated logos are trade marks. © WarmupPlc. 2010 - Regd. TM Nos. 1257757, 4409926, 5265707. E & OE. Registeredin England No. 2955213.
DRAWING NO
CAD FILE
WARMUP PLC, 704 Tudor Estate, Abbey Road, London,NW10 7UW Tel 0845 034 8270 Fax 0208 453 6869
[email protected] [email protected] www.warmup.co.uk
TITLE
DETAILED SECTION
CONSTRUCTION 05
TOTAL-16 LOW PROFILE SYSTEMCONCRETE SUBFLOOR
<14mm WOOD/LAMINATE FLOOR-FLOATING
21.12.2016
20161215-H-T16-DET SECTIONS.DWG
AA
1:50@A3
AW
07_ UFH compatible timber floor adhesive
08_ Timber floor finish
06_ Warmup Dual Overlay Concrete or 18 mm T&G P5 Chipboard floor
WARMUP TOTAL16. Concrete subfloor. Wood / Laminate floor - glued
01_ Subfloor to SR1 standard
02_ Warmup perimeter expansion strip or 10 mm expansion gap
03_ Warmup Total-16 Panel
04_ Warmup 12mm pipework
05_ 1 mm Polyethylene foam or equivalent
REV DATE DESCRIPTION DR CH
DRAWING ISSUE STATUS
PROJECT
PROJECT MANAGER DRAWN CHECKED
DATE SCALE REVISION
© This drawing is confidential and may not be used, copied ordisclosed to anyone without permission of Warmup Plc. The Copyrightof these drawings remain the property of Warmup Plc.
Do not scale from drawings, all dimensions to be checked on site.
The Warmup word and associated logos are trade marks. © WarmupPlc. 2010 - Regd. TM Nos. 1257757, 4409926, 5265707. E & OE. Registeredin England No. 2955213.
DRAWING NO
CAD FILE
WARMUP PLC, 704 Tudor Estate, Abbey Road, London,NW10 7UW Tel 0845 034 8270 Fax 0208 453 6869
[email protected] [email protected] www.warmup.co.uk
TITLE
DETAILED SECTION
CONSTRUCTION 06
TOTAL-16 LOW PROFILE SYSTEMCONCRETE SUBFLOOR
WOOD / LAMINATE FLOOR - GLUED
21.12.2016
20161215-H-T16-DET SECTIONS.DWG
AA
1:50@A3
AW
09_ UFH compatible underlay
10_ Floating vinyl floor finish
07_ Warmup Dual Overlay Concrete or 18 mm T&G P5 Chipboard floor
08_ 2-3 mm Smoothing compound
WARMUP TOTAL16. Concrete subfloor. Vinyl floor - floating
03_ Warmup perimeter expansion strip or 10 mm expansion gap
04_ Warmup Total-16 Panel
05_ Warmup 12mm pipework
01_ Subfloor to SR1 standard
02_ Warmup Glue [WHS-X-GLUE]*
06_ 1 mm Polyethylene foam or equivalent
REV DATE DESCRIPTION DR CH
DRAWING ISSUE STATUS
PROJECT
PROJECT MANAGER DRAWN CHECKED
DATE SCALE REVISION
© This drawing is confidential and may not be used, copied ordisclosed to anyone without permission of Warmup Plc. The Copyrightof these drawings remain the property of Warmup Plc.
Do not scale from drawings, all dimensions to be checked on site.
The Warmup word and associated logos are trade marks. © WarmupPlc. 2010 - Regd. TM Nos. 1257757, 4409926, 5265707. E & OE. Registeredin England No. 2955213.
DRAWING NO
CAD FILE
WARMUP PLC, 704 Tudor Estate, Abbey Road, London,NW10 7UW Tel 0845 034 8270 Fax 0208 453 6869
[email protected] [email protected] www.warmup.co.uk
TITLE
DETAILED SECTION
CONSTRUCTION 07
TOTAL-16 LOW PROFILE SYSTEMCONCRETE SUBFLOOR
VINYL FLOOR - FLOATING
21.12.2016
20161215-H-T16-DET SECTIONS.DWG
AA
1:50@A3
AW
09_ UFH compatible vinyl floor adhesive
10_ Vinyl floor finish
07_ Warmup Dual Overlay Concrete or 18 mm T&G P5 Chipboard floor
08_ 2-3 mm Smoothing compound
WARMUP TOTAL16. Concrete subfloor. Vinyl floor - floating
03_ Warmup perimeter expansion strip or 10 mm expansion gap
04_ Warmup Total-16 Panel
05_ Warmup 12mm pipework
01_ Subfloor to SR1 standard
02_ Warmup Glue [WHS-X-GLUE]*
06_ 1 mm Polyethylene foam or equivalent
REV DATE DESCRIPTION DR CH
DRAWING ISSUE STATUS
PROJECT
PROJECT MANAGER DRAWN CHECKED
DATE SCALE REVISION
© This drawing is confidential and may not be used, copied ordisclosed to anyone without permission of Warmup Plc. The Copyrightof these drawings remain the property of Warmup Plc.
Do not scale from drawings, all dimensions to be checked on site.
The Warmup word and associated logos are trade marks. © WarmupPlc. 2010 - Regd. TM Nos. 1257757, 4409926, 5265707. E & OE. Registeredin England No. 2955213.
DRAWING NO
CAD FILE
WARMUP PLC, 704 Tudor Estate, Abbey Road, London,NW10 7UW Tel 0845 034 8270 Fax 0208 453 6869
[email protected] [email protected] www.warmup.co.uk
TITLE
DETAILED SECTION
CONSTRUCTION 08
TOTAL-16 LOW PROFILE SYSTEMCONCRETE SUBFLOOR
VINYL FLOOR - GLUED
21.12.2016
20161215-H-T16-DET SECTIONS.DWG
AA
1:50@A3
AW
09_ UFH compatible underlay
10_ Carpet floor finish
07_ Warmup Dual Overlay Concrete or 18 mm T&G P5 Chipboard floor
WARMUP TOTAL16. Concrete subfloor. Carpet floor
03_ Warmup perimeter expansion strip or 10 mm expansion gap
04_ Warmup Total-16 Panel
05_ Warmup 12mm pipework
01_ Subfloor to SR1 standard
02_ Warmup Glue [WHS-X-GLUE]*
06_ 1 mm Polyethylene foam or equivalent
REV DATE DESCRIPTION DR CH
DRAWING ISSUE STATUS
PROJECT
PROJECT MANAGER DRAWN CHECKED
DATE SCALE REVISION
© This drawing is confidential and may not be used, copied ordisclosed to anyone without permission of Warmup Plc. The Copyrightof these drawings remain the property of Warmup Plc.
Do not scale from drawings, all dimensions to be checked on site.
The Warmup word and associated logos are trade marks. © WarmupPlc. 2010 - Regd. TM Nos. 1257757, 4409926, 5265707. E & OE. Registeredin England No. 2955213.
DRAWING NO
CAD FILE
WARMUP PLC, 704 Tudor Estate, Abbey Road, London,NW10 7UW Tel 0845 034 8270 Fax 0208 453 6869
[email protected] [email protected] www.warmup.co.uk
TITLE
DETAILED SECTION
CONSTRUCTION 09
TOTAL-16 LOW PROFILE SYSTEMCONCRETE SUBFLOOR
CARPET FLOOR
21.12.2016
20161215-H-T16-DET SECTIONS.DWG
AA
1:50@A3
AW