Download - Construction Fire Safety
![Page 1: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/1.jpg)
1
Construction Fire Safety
SUNY PPAA Winter 2012 Conference
Barbara Boyle, SUNYBill Held, SUCF
![Page 2: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/2.jpg)
2
Deutsche Bank
![Page 3: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/3.jpg)
3
![Page 4: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/4.jpg)
4
![Page 5: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/5.jpg)
5
August 2007 Fatal Fire
Robert Beddia, 53Joseph Graffagnino, 33
![Page 6: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/6.jpg)
6
3 contractor supervisors criminally indicted
Department of Building staff shuffle
Public rallies calling to improve building codes and their enforcement
NYFD accused of cover up
Changes to NYFD policies, training, SCBA use, crew integrity, communication, etc.
![Page 7: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/7.jpg)
7
Delayed notification of the fire by building construction personnel
Standpipe and sprinkler system inoperableDelay in establishing water supply Inaccurate information about standpipe
NIOSH investigators identified the following items as key contributing factors in this incident that led to the fatalities:
![Page 8: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/8.jpg)
8
Unique building conditions with both asbestos abatement and deconstruction occurring simultaneously Blocked stairwells preventing fire fighter access and egress Maze-like interior conditions from partitions and
construction debris Extreme fire behavior; uncontrolled fire rapidly progressing
and extending below the fire floor Heavy smoke conditions causing numerous fire fighters to
become lost or disoriented
![Page 9: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/9.jpg)
9
Failure of fire fighters to always don SCBAs inside structure and replenish air cylinders
Communications overwhelmed with numerous Mayday and urgent radio transmissions
Lack of crew integrity
![Page 10: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/10.jpg)
10
Recommendation 14:
Municipalities should ensure that construction and/or demolition is done in accordance with NFPA 241: Standard for Safeguarding Construction, Alteration, and Demolition Operations.
![Page 11: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/11.jpg)
11
7.6 ―Fire Protection: Standpipes
10.8.4 ―Safeguarding Construction and Alteration Operations: Standpipes
10.4 ―Safeguarding Demolition Operations: Smoking
10.8.2 ―Safeguarding Construction and Alteration Operations: Fire Protection During Demolition, System Operation
![Page 12: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/12.jpg)
12
Photo 4. Standpipe system was inoperable due to missing sections of pipe. (Photos courtesy of fire department/NIOSH report.)
![Page 13: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/13.jpg)
13
Recommendation 15: Municipalities should develop a reporting system to inform the fire department of any ongoing, unique building construction activities (such as deconstruction or asbestos abatement) that would adversely affect a fire response.
![Page 14: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/14.jpg)
14
Photo 5. Plastic sheeting, ductwork and fans used for asbestos abatement. (Photos courtesy of fire department/NIOSH report.)
![Page 15: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/15.jpg)
15
Recommendation 16: Municipalities should establish a system for property owners to notify the fire department when fire protection/suppression systems are taken out of service.
![Page 16: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/16.jpg)
16
Deutsche Bank news releases
OFPC 2011 presentation at Cooperstown
NIOSH reports
Hmmm……
![Page 17: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/17.jpg)
17
![Page 18: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/18.jpg)
18
NYS Fire Code Chapter 14Fire Safety During Construction and
Demolition
![Page 19: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/19.jpg)
19
Applies to structures in the course of construction, alternation, or demolition.
Prescribes minimum safeguards to provide reasonable safety to life and property from fire.
Compliance with NFPA 241 is required for items not specifically addressed herein.
1401 General
![Page 20: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/20.jpg)
20
1402 Definitions
1403 Temporary Heating EquipmentListed and labeled/clearances/refueling
1404 Precautions Against FireNo smokingDebris removal each shiftFire watches
![Page 21: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/21.jpg)
21
1405 Flammable and Combustible Liquids
1406 Flammable gases Chapter 36
1407 Explosive Materials Chapter 33
![Page 22: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/22.jpg)
22
1408 Owners Responsibility for Fire Protection
![Page 23: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/23.jpg)
23
The owner shall designate a person to be the Fire Prevention Program Superintendent who shall be responsible for the fire prevention program and ensure that it is carried out through completion of the project.
the authority to enforce … provisions as necessary to secure the intent of this Chapter.
§F1408.1 Program superintendent
![Page 24: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/24.jpg)
24
Fire Prevention Program Superintendent
![Page 25: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/25.jpg)
25
The fire prevention program superintendent shall develop and maintain an approved prefire plan in cooperation with the fire chief.
§F1408.2 Prefire plans
![Page 26: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/26.jpg)
26
![Page 27: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/27.jpg)
27
Training of responsible personnel in the use of fire protection equipment shall be the responsibility of the fire prevention program superintendent.
§F1408.3 Training
![Page 28: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/28.jpg)
28
The fire prevention program superintendent shall determine that all fire protection equipment is maintained and serviced in accordance with this code.
The quantity and type of fire protection equipment shall be approved.
§F1408.4 Fire protection devices
![Page 29: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/29.jpg)
29
The fire prevention program superintendent shall be responsible for supervising the hot work operations in accordance with Chapter F26.
§F1408.5 Hot work operations
![Page 30: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/30.jpg)
30
Hot Work Basics Welding, cutting, brazing
Posted PermitAuthorizing partyAuthorized timeAuthorized locationDaily inspections
![Page 31: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/31.jpg)
31
Sprinklers functioning
Equipment in good repair
Cleared or covered 35 ft
Opening protected
Floors are kept clean
![Page 32: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/32.jpg)
32
Fire watchesDuring and minimum 30 minutes (longer period
may be required)
Trained person, sole function
Fire extinguisher
Communication means
![Page 33: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/33.jpg)
33
§F1408.6 Impairment of fire protection systems
§F1408.7 Temporary covering of fire protection devices
![Page 34: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/34.jpg)
34
Emergency telephone
readily accessible emergency phone facilities
approved location at the construction site
street address of site and the emergency phone number must be posted adjacent to the telephone.
1409 Fire Reporting
![Page 35: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/35.jpg)
35
Required access Approved temporary or permanent roads, capable of
supporting vehicle loading under all weather conditions
• Within 100 feet of temporary or permanent fire department connections
Key boxes Key boxes shall be provided as required by Chapter F5.
1410 Access for Fire Fighting
![Page 36: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/36.jpg)
36
Stairways required greater than 50 feet or four stories at least one temporary lighted stairway shall be provided, unless
one or more of the permanent stairways are erected
Maintenance of Egress Required means of egress shall be maintained during construction
and demolition, remodeling or alterations and additions.
Stairway floor number signs Temporary stairway floor number signs shall be approved
1411 Means of Egress
![Page 37: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/37.jpg)
37
![Page 38: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/38.jpg)
38
![Page 39: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/39.jpg)
39
When requiredAn approved water supply for fire protection,
either temporary or permanent, shall be made available as soon as combustible material arrives on the site.
1412 Water Supply for Fire Protection
![Page 40: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/40.jpg)
40
§F1413.1 Where required four or more stories in height
fire department hose connections at accessible locations adjacent to usable stairs
Such standpipes are to be be extended (taken down) as construction (demolition) progresses to within one floor.
1413 Standpipes
![Page 41: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/41.jpg)
41
1414 Automatic Sprinkler Systems
1415 Portable Fire Extinguishers Each stairway on all floor levels Every storage and construction shed To address hazards
1416 Motorized Hazards
1417 Safeguarding Roofing operations
![Page 42: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/42.jpg)
42
![Page 43: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/43.jpg)
43
![Page 44: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/44.jpg)
44
![Page 45: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/45.jpg)
45
Expectations Prime players Lines of responsibilities Lines of communication
Training
Weekly InspectionsChecklist Tool
![Page 46: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/46.jpg)
46
![Page 47: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/47.jpg)
47
![Page 48: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/48.jpg)
48
![Page 49: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/49.jpg)
49
![Page 50: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/50.jpg)
50
![Page 51: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/51.jpg)
51
![Page 52: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/52.jpg)
52
![Page 53: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/53.jpg)
53
![Page 54: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/54.jpg)
54
![Page 55: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/55.jpg)
55
![Page 56: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/56.jpg)
56
![Page 57: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/57.jpg)
57
![Page 58: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/58.jpg)
58
![Page 59: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/59.jpg)
59
![Page 60: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/60.jpg)
60
![Page 61: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/61.jpg)
61
![Page 62: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/62.jpg)
62
![Page 63: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/63.jpg)
63
![Page 64: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/64.jpg)
64
![Page 65: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/65.jpg)
65
![Page 66: Construction Fire Safety](https://reader038.vdocuments.site/reader038/viewer/2022102714/56815f62550346895dce4ec0/html5/thumbnails/66.jpg)
66
Improve Fire Safety Improve Communication between various
groups Training outreach Better document the processes in place Better manage the risks
Work in Progress…..