Transcript
TESTINGPROJECT15 MGD SEWAGE TREATMENT PLANT , AT DELHI NALLA GATE ( PHASE-II ) , NEW DELHICLIENTDELHI JAL BOARDCONSULTANTCONTRACTORDEGREMONT LTDDOCUMENT TITLEI-O LISTDOCUMENT NO.DGT-000-0-LI-IN-001 11.MAR.2013DOCUMENT SUB TITLEIO LIST FILTER CONSOLE-3A (BIOFOR STAGE-I)Sr.NoSYSTEM TAGDESCRIPTIONPLC ADDRESSFROMTOPANEL NO.TB NO.TB GROUPSTATUSDIGITAL INPUT1492A1MM001__ZSHBiofor Stage-1 Air Purge Valve 492A1MM001_Open Feed Back%I0001FieldFilter ConsolePANEL-11,21XDI13OK2492A1MM001__ZSLBiofor Stage-1 Air Purge Valve 492A1MM001_Close Feedback%I0002FieldFilter ConsolePANEL-13,4OK3492A1MM001__LCLBiofor Stage-1 Air Purge Valve 492A1MM001_Local%I0003FieldFilter ConsolePANEL-15,6OK4492A1MM001__REMBiofor Stage-1 Air Purge Valve 492A1MM001_Remote%I0004FieldFilter ConsolePANEL-17,8OK5492A1MM001__FLTBiofor Stage-1 Air Purge Valve 492A1MM001_Fault%I0005FieldFilter ConsolePANEL-19,10OK6492A1MM002__ZSHBiofor Stage-1 Backwash Inlet Valve 492A1MM002_Open Feed Back%I0006FieldFilter ConsolePANEL-111,121OK7492A1MM002__ZSLBiofor Stage-1 Backwash Inlet Valve 492A1MM002_Close Feedback%I0007FieldFilter ConsolePANEL-113,14OK8492A1MM002__LCLBiofor Stage-1 Backwash Inlet Valve 492A1MM002_Local%I0008FieldFilter ConsolePANEL-115,16OK9492A1MM002__REMBiofor Stage-1 Backwash Inlet Valve 492A1MM002_Remote%I0009FieldFilter ConsolePANEL-117,18OK10492A1MM002__FLTBiofor Stage-1 Backwash Inlet Valve 492A1MM002_Fault%I0010FieldFilter ConsolePANEL-119,20OK11492A1MM003__ZSHBiofor Stage-1 Inlet Valve 492A1MM003_Open Feed Back%I0011FieldFilter ConsolePANEL-121,222OK12492A1MM003__ZSLBiofor Stage-1 Inlet Valve 492A1MM003_Close Feedback%I0012FieldFilter ConsolePANEL-123,24OK13492A1MM003__LCLBiofor Stage-1 Inlet Valve 492A1MM003_Local%I0013FieldFilter ConsolePANEL-125,26NOT OKSELECTOR SWITCH CONTATS ARE NOT CHANGING14492A1MM003__REMBiofor Stage-1 Inlet Valve 492A1MM003_Remote%I0014FieldFilter ConsolePANEL-127,28NOT OK15492A1MM003__FLTBiofor Stage-1 Inlet Valve 492A1MM003_Fault%I0015FieldFilter ConsolePANEL-129,30NOT OK16492A1MM004__ZSHBiofor Stage-1 Backwash Outlet Valve 492A1MM004_Open Feed Back%I0016FieldFilter ConsolePANEL-131,325OK17492A1MM004__ZSLBiofor Stage-1 Backwash Outlet Valve 492A1MM004_Close Feedback%I0017FieldFilter ConsolePANEL-133,34NOT OKLIMIT SWITCH PROBLEM18492A1MM004__LCLBiofor Stage-1 Backwash Outlet Valve 492A1MM004_Local%I0018FieldFilter ConsolePANEL-135,36OK19492A1MM004__REMBiofor Stage-1 Backwash Outlet Valve 492A1MM004_Remote%I0019FieldFilter ConsolePANEL-137,38OK20492A1MM004__FLTBiofor Stage-1 Backwash Outlet Valve 492A1MM004_Fault%I0020FieldFilter ConsolePANEL-139,40OK21492A1MM005__ZSHBiofor Stage-1 Air Scour Valve 492A1MM005_Open Feed Back%I0021FieldFilter ConsolePANEL-141,424OK22492A1MM005__ZSLBiofor Stage-1 Air Scour Valve 492A1MM005_Close Feedback%I0022FieldFilter ConsolePANEL-143,44OK23492A1MM005__LCLBiofor Stage-1 Air Scour Valve 492A1MM005_Local%I0023FieldFilter ConsolePANEL-145,46OK24492A1MM005__REMBiofor Stage-1 Air Scour Valve 492A1MM005_Remote%I0024FieldFilter ConsolePANEL-147,48OK25492A1MM005__FLTBiofor Stage-1 Air Scour Valve 492A1MM005_Fault%I0025FieldFilter ConsolePANEL-149,50OK26492A1MM006__ZSHBiofor Stage-1 Process Air Valve 492A1MM006_Open Feed Back%I0026FieldFilter ConsolePANEL-151,526OK27492A1MM006__ZSLBiofor Stage-1 Process Air Valve 492A1MM006_Close Feedback%I0027FieldFilter ConsolePANEL-153,54OK28492A1MM006__LCLBiofor Stage-1 Process Air Valve 492A1MM006_Local%I0028FieldFilter ConsolePANEL-155,56OK29492A1MM006__REMBiofor Stage-1 Process Air Valve 492A1MM006_Remote%I0029FieldFilter ConsolePANEL-157,58OK30492A1MM006__FLTBiofor Stage-1 Process Air Valve 492A1MM006_Fault%I0030FieldFilter ConsolePANEL-159,60OK31492A1_LSH001_Biofor Stage-1 Level switch 492A1_LSH001_ Level High%I0031FieldFilter ConsolePANEL-161,62DIGITAL OUTPUT1492A1MM001_ _OP_CMDBiofor Stage-1 Air Purge Valve 492A1MM001_Open Command%Q001Filter ConsoleFieldPANEL-11,21XDO13OK2492A1MM001_ _CLS_CMDBiofor Stage-1 Air Purge Valve 492A1MM001_Close Command%Q002Filter ConsoleFieldPANEL-13,4OK3492A1MM002__OP_CMDBiofor Stage-1 Backwash Inlet Valve 492A1MM002_Open Command%Q003Filter ConsoleFieldPANEL-15,61OK4492A1MM002__CLS_CMDBiofor Stage-1 Backwash Inlet Valve 492A1MM002_Close Command%Q004Filter ConsoleFieldPANEL-17,8OK5492A1MM003__OP_CMDBiofor Stage-1 Inlet Valve 492A1MM003_Open Command%Q005Filter ConsoleFieldPANEL-19,102OK6492A1MM003__CLS_CMDBiofor Stage-1 Inlet Valve 492A1MM003_Close Command%Q006Filter ConsoleFieldPANEL-111,12OK7492A1MM004__OP_CMDBiofor Stage-1 Backwash Outlet Valve 492A1MM004_Open Command%Q007Filter ConsoleFieldPANEL-113,145OK8492A1MM004__CLS_CMDBiofor Stage-1 Backwash Outlet Valve 492A1MM004_Close Command%Q008Filter ConsoleFieldPANEL-115,16OK9492A1MM005__OP_CMDBiofor Stage-1 Air Scour Valve 492A1MM005_Open Command%Q009Filter ConsoleFieldPANEL-117,184OK10492A1MM005__CLS_CMDBiofor Stage-1 Air Scour Valve 492A1MM005_Close Command%Q010Filter ConsoleFieldPANEL-119,20OK11492A1MM006__OP_CMDBiofor Stage-1 Process Air Valve 492A1MM006_Open Command%Q011Filter ConsoleFieldPANEL-121,226OK12492A1MM006__CLS_CMDBiofor Stage-1 Process Air Valve 492A1MM006_Close Command%Q012Filter ConsoleFieldPANEL-123,24ANALOG INPUT1492A1_FITx_001_492A1_FITx_001_ Thermal Mass Flowmeter - Process Air Blower%AI0001PANEL-11,2,3,51XAI1OK2492A1_AITx_001_492A1_AITx_001_ Dissolve Oxygen Analyzer at Outlet of Biofor Stage-1%AI0002PANEL-14,5,6,5OK3492A1_PITx_001_492A1_PITx_001_ Pressure Transmitter%AI0003PANEL-17,8,9,5
&R&"Verdana,Bold"&P of &N

Top Related