-
Automotive & PowersportsTHE FACTS ABOUT YOUR INTAKE & AIR
ISO 5011 Tested to Make Sure You Maximize Airflow While Still Protecting Your Engine.
TECHNICAL BULLETINThere is a lot of misinformation in the marketplace. S&B publishes specific test results for each of our intakes & filters as shown below, so you can make an informed decision. Remember, improving your airflow is only good if your engine is still protected. That’s the S&B difference!
FACT: S&B Flows 53.66% Better than StockIn tests performed in our climate controlled laboratory according to the ISO5011 Test Standard, S&B’s intake kit (and filter) had significantly lower restriction (better airflow) than the stock intake system. See the graph on the next page.
WATCH OUT: Some competitors over state airflow.If they state that their filter will flow, lets say 1000 cfm, without stating at what restriction level, they are trying to mislead you.
Part Number: 75-5062, 75-5062DDescription: Performance Intake Kit & FilterVehicle Applications: 1998-2003 Ford Powerstroke 7.3L
Test Date: 03/21/18Test Report #: 1, 2, 3, 4, 5, 6
Description % S&B Flowed Better than Stock(tested @ 631 cfm)
S&B Intake w/ Cleanable Filter 53.66%
S&B Intake w/ Dry Filter 51.43%
Barometric Pressure 28.98
Airflow Setpoint 631 cfm
Relative Humidity 50
Temperature 70.2F
Type of Dust ISO Coarse
Batch # 13228C
Dust Feed Rate (grams/minute) 17.87
TEST CONDITIONS
-
WATCH OUT: Some Competitors Use the Same Efficiency Rates for Multiple Part Numbers.Many send one filter off to a lab to be tested at a low cfm and then publish this efficiency rate for all of their part numbers.
FACT: S&B Protects Your EngineS&B tests at the highest rated CFM for your vehicle when determining the efficiency rate (amount of dust the filter stops), so that we can be sure that your engine will be protected.
Description Efficiency Rate (tested @ 631 cfm)
Stock 99.67%
S&B Intake w/ Cleanable Filter 99.37%
S&B Intake w/ Dry Filter 99.68%
0
5
10
15
20
25
30
35
300 400 500 600 700 800 900 1000 1100
Restriction(InchesofH2O
)
AirflowCFMAirFlowvsRestriction
StockIntake S&BIntakew/CleanableFilter S&BIntakew/DryFilter
MORERESTR
ICTION
LESSRESTR
ICTIO
N
-
Test #: 399 Operator: SDSample #: 1 Report Date: 3/21/2017
Filter #: FA1680 Filter Mfg.:Housing #: Housing Mfg.:Date Code:
Test Description: STOCK INTAKE AND FILTER, NO SENSORS, NO FILTER MINDER, MOTORCRAFT# FA1680
Barometric Pressure: 28.95804 in. Hg Relative Humidity: 50 %Air Flow Type: SCFM Temperature: 65 deg. F
Number of Pleats: Pleat Depth: in.Flow Direction:
Flow Rate Differential Pressure315 3.74473 8.02629 13.94787 21.98944 31.92
Air Flow Curve Data
Air Filter Restriction Test Report
Test Conditions
0.00
5.00
10.00
15.00
20.00
25.00
30.00
35.00
0.0 100.0 200.0 300.0 400.0 500.0 600.0 700.0 800.0 900.0 1000.0
Pres
sure
Diff
. (in
. H2O
)
Flow Rate (SCFM)
Air Flow Curve
-
Test #: 399 Operator: SDSample #: 3 Report Date: 3/21/2017
Filter #: KF-1059 Filter Mfg.:Housing #: 75-5062 Housing Mfg.:Date Code:
Test Description: 75-5062 PRODUCTION KIT, NO SENSORS NO FILTER MINDER, LID INSTALLED, FENDER SEAL INSTALLEDKF-1059
Barometric Pressure: 28.9595 in. Hg Relative Humidity: 47 %Air Flow Type: SCFM Temperature: 68 deg. F
Number of Pleats: Pleat Depth: in.Flow Direction:
Flow Rate Differential Pressure315 1.84474 3.73631 6.46788 9.89944 14.14
Air Flow Curve Data
Air Filter Restriction Test Report
Test Conditions
0.00
2.00
4.00
6.00
8.00
10.00
12.00
14.00
16.00
0.0 100.0 200.0 300.0 400.0 500.0 600.0 700.0 800.0 900.0 1000.0
Pres
sure
Diff
. (in
. H2O
)
Flow Rate (SCFM)
Air Flow Curve
-
Test #: 339 Operator: SDSample #: 4 Report Date: 3/21/2017
Filter #: KF-1059 Filter Mfg.:Housing #: 75-5062 Housing Mfg.:Date Code:
Test Description: 75-5062 PRODUCTION KIT, NO SENSORS, NO FILTER MINDER, LID INSTALLED, FENDER SEAL INSTALLEDKF-1059D
Barometric Pressure: 28.96146 in. Hg Relative Humidity: 48 %Air Flow Type: SCFM Temperature: 68 deg. F
Number of Pleats: Pleat Depth: in.Flow Direction:
Flow Rate Differential Pressure314 1.96473 4.00630 6.77787 10.50942 15.00
Air Flow Curve Data
Air Filter Restriction Test Report
Test Conditions
0.00
2.00
4.00
6.00
8.00
10.00
12.00
14.00
16.00
0.0 100.0 200.0 300.0 400.0 500.0 600.0 700.0 800.0 900.0 1000.0
Pres
sure
Diff
. (in
. H2O
)
Flow Rate (SCFM)
Air Flow Curve
-
Test #: 399 Operator: SDSample #: 2 Report Date: 3/21/2017
Filter #: FA1680 Filter Mfg.:Housing #: Housing Mfg.:Date Code:
Test Description: STOCK INTAKE AND FILTER, NO SENSORS, NO FILTER MINDER, MOTORCRAFT# FA1680
Barometric Pressure: 28.960 in. Hg Relative Humidity: 48 %Air Flow Setpoint: 631 SCFM Type of Dust: A4 COARSE
Test Procedure: Batch #: 13228CAir Flow Type: SCFM Temperature: 67 deg. FTest Endpoint: 10 in. H2O Initial Add Rate: NaN g/min
Number of Pleats: Accumulative Add Rate: 17.87 g/minFlow Direction: Pleat Depth: in.
Initial Delta P 13.88 in. H2O Accumulative Capacity: 233.50 gTest Time: 13.06 min
Initial AccumulativeBlanket Blanket
Start 5598.60 175.20End 5832.10 175.97Gain 233.50 0.77Efficiency 99.67%
Dust Fed (g) Pressure ("H2O)0
Air Filter Full Life Efficiency Test Report
Test Conditions
Test Results
Dust Loading Curve Data
105.764123.671141.683159.63177.439
16.77234.55652.58270.19588.166
195.211213.045231.095234.401
19.64321.51724.31824.566
13.76414.23214.29814.71614.86415.23415.46815.96216.42417.18418.162
0
5
10
15
20
25
30
0 50 100 150 200 250
H2O
"
Dust Fed (g)
Dust Loading Curve
-
Test #: 399 Operator: SDSample #: 5 Report Date: 3/21/2017
Filter #: KF-1059 Filter Mfg.:Housing #: 75-5062 Housing Mfg.:Date Code:
Test Description: 75-5062 PRODUCTION KIT, NO SENSORS, NO FILTER MINDER, LID INSTALLED, FENDER SEAL INSTALLEDKF-1059
Barometric Pressure: 28.967 in. Hg Relative Humidity: 47 %Air Flow Setpoint: 631 SCFM Type of Dust: A4 COARSE
Test Procedure: Batch #: 13228CAir Flow Type: SCFM Temperature: 68 deg. FTest Endpoint: 10 in. H2O Initial Add Rate: NaN g/min
Number of Pleats: Accumulative Add Rate: 17.87 g/minFlow Direction: Pleat Depth: in.
Initial Delta P 6.40 in. H2O Accumulative Capacity: 220.40 gTest Time: 12.44 min
Initial AccumulativeBlanket Blanket
Start 6403.30 135.95End 6623.70 137.35Gain 220.40 1.40Efficiency 99.37%
Dust Fed (g) Pressure ("H2O)0
Air Filter Full Life Efficiency Test Report
Test Conditions
Test Results
Dust Loading Curve Data
106.683124.51142.267160.25178.098
17.4535.17653.19
71.05488.894
195.829213.784221.338
12.92515.37316.711
6.2726.3876.6166.877.1217.4817.9448.4429.1629.932
11.175
0
2
4
6
8
10
12
14
16
18
0 50 100 150 200 250
H2O
"
Dust Fed (g)
Dust Loading Curve
-
Test #: 399 Operator: SDSample #: 6 Report Date: 3/21/2017
Filter #: KF-1059D Filter Mfg.:Housing #: 75-5062 Housing Mfg.:Date Code:
Test Description: 75-5062 PRODUCTION KIT, NO SENSORS, NO FILTER MINDER, LID INSTALLED, FENDER SEAL INSTALLEDKF-1059D
Barometric Pressure: 28.935 in. Hg Relative Humidity: 47 %Air Flow Setpoint: 631 SCFM Type of Dust: A4 COARSE
Test Procedure: Batch #: 13228CAir Flow Type: SCFM Temperature: 68 deg. FTest Endpoint: 10 in. H2O Initial Add Rate: NaN g/min
Number of Pleats: Accumulative Add Rate: 17.87 g/minFlow Direction: Pleat Depth: in.
Initial Delta P 6.72 in. H2O Accumulative Capacity: 232.00 gTest Time: 13.06 min
Initial AccumulativeBlanket Blanket
Start 6363.60 137.35End 6595.60 138.10Gain 232.00 0.75Efficiency 99.68%
Dust Fed (g) Pressure ("H2O)0
Air Filter Full Life Efficiency Test Report
Test Conditions
Test Results
Dust Loading Curve Data
106.785124.981142.89160.586178.361
17.48735.34753.22470.91588.66
196.556214.509232.354232.715
11.90713.86417.32617.229
6.6466.7086.7496.7546.8357.1097.3617.7588.3389.237
10.278
0
2
4
6
8
10
12
14
16
18
20
0 50 100 150 200 250
H2O
"
Dust Fed (g)
Dust Loading Curve