Download - Aselco Ff Isa Es 2006
![Page 1: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/1.jpg)
1
SEU RESULTADO ÉSEU RESULTADO É
NOSSO NEGÓCIONOSSO NEGÓCIO
![Page 2: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/2.jpg)
2
ÁREAS DE ATUAÇÃO ÁREAS DE ATUAÇÃO
![Page 3: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/3.jpg)
3
ANALÍTICA &
CONDICIONAMENTO AMOSTRAS
AUTOMAÇÃO PARA ÁREAS
CLASSIFICADAS
MEDIÇÃO FISCAL &
TRANSFERÊNCIA DE CUSTÓDIA
PROTEÇÃO E INTEGRIDADE
DE DUTOS
![Page 4: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/4.jpg)
4
ANALÍTICA E CONDICIONAMENTO ANALÍTICA E CONDICIONAMENTO AMOSTRAS AMOSTRAS ANALÍTICA E CONDICIONAMENTO ANALÍTICA E CONDICIONAMENTO AMOSTRAS AMOSTRAS
ANALISADORES DE O2 CEMS TOG
CONDICIONAMENTO DE AMOSTRAS
COLETORES DE AMOSTRAS
![Page 5: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/5.jpg)
5
MEDIÇÃO FISCAL E MEDIÇÃO FISCAL E TRANSFERÊNCIA DE CUSTÓDIATRANSFERÊNCIA DE CUSTÓDIAMEDIÇÃO FISCAL E MEDIÇÃO FISCAL E TRANSFERÊNCIA DE CUSTÓDIATRANSFERÊNCIA DE CUSTÓDIA
CROMATÓGRAFOCOMPUTADORES DE VAZÃO –
GN E LIQUIDOS
ESTAÇÕES DE MEDIÇÃO GN ANALISADOR DE UMIDADE
![Page 6: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/6.jpg)
6
PROTEÇÃO E INTEGRIDADEPROTEÇÃO E INTEGRIDADEDE DUTOSDE DUTOSPROTEÇÃO E INTEGRIDADEPROTEÇÃO E INTEGRIDADEDE DUTOSDE DUTOS
MONITORAÇÃO DE CORROSÃO
“ON LINE” e “OFF LINE”
SISTEMA ACÚSTICO DE DETECÇÃO DE VAZAMENTO
![Page 7: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/7.jpg)
7
AUTOMAÇÃO EM ÁREAS AUTOMAÇÃO EM ÁREAS CLASSIFICADASCLASSIFICADASAUTOMAÇÃO EM ÁREAS AUTOMAÇÃO EM ÁREAS CLASSIFICADASCLASSIFICADAS
BARREIRAS E ISOLADORES I.S. PROTETORES DE SURTO
I/O REMOTO
(Zona 2 e Zona 1)
FOUNDATION FIELDBUS
![Page 8: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/8.jpg)
8
TÓPICOS TÓPICOS TÓPICOS TÓPICOS
• Arquitetura FieldBus
• Conceitos : FNICO e FISCO
• Dimensionamento de condicionadores
• Produtos FieldBus
![Page 9: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/9.jpg)
9
ARQUITETURA ARQUITETURA
![Page 10: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/10.jpg)
10
TOPOLOGIASTOPOLOGIASTOPOLOGIASTOPOLOGIAS
• Árvore: Concentra a conexão de diversos dispositivos de campo em caixas de junção.
• “End to End”: É utilizada para a conexão direta de dois dispositivos;
• Ponto-a-Ponto: Todos dispositivos são ligados em série. Raramente é utilizada, já que uma falha em um dispositivo na rede resultará na falha de toda a rede;
• Barramentos com Spurs (Drops): Instrumentos interligados no barramento com conectores tipo T;
• Misto: Como o próprio nome indica.
![Page 11: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/11.jpg)
11
CONCEITOS CONCEITOS SPUR E TRUNKSPUR E TRUNKCONCEITOS CONCEITOS SPUR E TRUNKSPUR E TRUNK
TPFPS T
S1S2
S3
Sn
T1
T TT1
S1 S2 S3 Sn
PFPS
T1 - TRUNKS1 - SPUR
![Page 12: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/12.jpg)
12
CONCEITOS CONCEITOS CABOS DISPONÍVEISCABOS DISPONÍVEISCONCEITOS CONCEITOS CABOS DISPONÍVEISCABOS DISPONÍVEIS
Tipo Descritivos Tamanho Compr.
Max
A Shielded, Twisted Pair #18 AWG (.8 mm2)
1900 m (6232 ft.)
B Multiple-Twisted-Pair with Shield
#22 AWG (.32 mm2)
1200 m (3963 ft.)
C Multi-Twisted-Pair Without Shield
#26 AWG (.13 mm2)
400 m (1312 ft.)
D Multi-core, w/o Twisted Pairs and Having Overall Shield
#16 AWG (1.25 mm2)
200 m (656 ft.)
![Page 13: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/13.jpg)
13
• O comprimento total do cabo deve ser menor que 1900m (shielded, 18 AWG, Type A)
• Quando conectado até 12 instrumentos no barramento energizado, o limite do comprimento do Spur deve ser:
* 120 m com um instrumento;
* 90 m com dois instrumentos;
* 60 m com três instrumentos;
* 30 m com quatro instrumentos;
CONCEITOS CONCEITOS EXEMPLO DE USO CABOSEXEMPLO DE USO CABOSCONCEITOS CONCEITOS EXEMPLO DE USO CABOSEXEMPLO DE USO CABOS
![Page 14: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/14.jpg)
14
ARQUITETURA - EXEMPLOARQUITETURA - EXEMPLOARQUITETURA - EXEMPLOARQUITETURA - EXEMPLO
S1+S2+S3+S4+S5+S6+S7+T1+T2 < 1900 M
Trunk
Spur
S1 S2 S3
S4 S5
T1JB T
S6 S7
T2T
![Page 15: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/15.jpg)
15
ARQUITETURA - DISTÂNCIAS ARQUITETURA - DISTÂNCIAS MÁXIMAS COM REPETIDORESMÁXIMAS COM REPETIDORESARQUITETURA - DISTÂNCIAS ARQUITETURA - DISTÂNCIAS MÁXIMAS COM REPETIDORESMÁXIMAS COM REPETIDORES
PHYSICAL LAYER
DISTANCE CAN BE INCREASED WITH REPEARTERSMAXIMUM = 4
REP1 REP2 REP3 REP4
1.900 M 1.900 M 1.900 M 1.900 M 1.900M
Terminator
![Page 16: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/16.jpg)
16
ARQUITETURA ARQUITETURA USO DO TERMINADORUSO DO TERMINADORARQUITETURA ARQUITETURA USO DO TERMINADORUSO DO TERMINADOR
• Utilizado para evitar reflexão de sinais no segmento Fieldbus.
• Exatamente dois terminadores por segmento.
100 Ohms 1 uF
![Page 17: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/17.jpg)
17
ARQUITETURA ARQUITETURA INSTALAÇÃO TERMINADORINSTALAÇÃO TERMINADORARQUITETURA ARQUITETURA INSTALAÇÃO TERMINADORINSTALAÇÃO TERMINADOR
JBT
condicionador
THostFieldbusInterface
T
Local do Terminador
![Page 18: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/18.jpg)
18
ARQUITETURA ARQUITETURA COMUNICAÇÃO – ATENUAÇÃO COMUNICAÇÃO – ATENUAÇÃO ARQUITETURA ARQUITETURA COMUNICAÇÃO – ATENUAÇÃO COMUNICAÇÃO – ATENUAÇÃO
T TT1
S1 S2 S3 Sn
PFPS
Normal
TT1
S1 S2 S3 Sn
PFPS ?
Falta um terminador
T TT1
S1 S2 S3 Sn
PFPS
Muitos terminadores
T T
![Page 19: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/19.jpg)
19
ARQUITETURA ARQUITETURA ATERRAMENTOATERRAMENTOARQUITETURA ARQUITETURA ATERRAMENTOATERRAMENTO
I
Obs.: O Shield deve ser aterrado em um único ponto
![Page 20: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/20.jpg)
20
ARQUITETURA ARQUITETURA INSTRUMENTOS POR SEGMENTOINSTRUMENTOS POR SEGMENTOARQUITETURA ARQUITETURA INSTRUMENTOS POR SEGMENTOINSTRUMENTOS POR SEGMENTO
• Entre 2 e 32 instrumentos numa ligação sem segurança intrínseca e com alimentação separada da fiação de comunicação;
• Entre 2 e 6 instrumentos alimentados pela mesma fiação de comunicação, numa ligação IS;
• Entre 1 e 12 instrumentos alimentados pela mesma fiação de comunicação, numa ligação não IS.
Obs.: Essa regra não proíbe a ligação de mais instrumentos do queespecificado. Deve-se atentar as limitações elétricas.
![Page 21: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/21.jpg)
21
FNICO
FISCO
FNICO
FISCO
![Page 22: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/22.jpg)
22
CONCEITOS CONCEITOS FNICO e FISCO FNICO e FISCO CONCEITOS CONCEITOS FNICO e FISCO FNICO e FISCO
- FISCO: Fieldbus Intrinsically Safe COncept
- FNICO: Fieldbus Non-Incendive COncept
- IEC-60079-27 / Abril-2005
![Page 23: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/23.jpg)
23
CONDICIONADORES FISCOCONDICIONADORES FISCO
Grupo IIB : •16 instrumentos (15mA)
Grupo IIC: •8 instrumentos (15mA)
INTRINSECAMENTE SEGUROS
265mA
120mA
![Page 24: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/24.jpg)
24
CONDICIONADORESFNICOCONDICIONADORESFNICO
Grupo IIB: 20 Instrumentos NI (15mA)
Grupo IIC: 12 Instrumentos NI (15mA)
NÃO INCENDÍVEL
320mA
180mA
![Page 25: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/25.jpg)
25
DIMENSIONAMENTODE
CONDICIONADORES
DIMENSIONAMENTODE
CONDICIONADORES
![Page 26: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/26.jpg)
26
CONDICIONADORES DE SINALSÉRIE FPSCONDICIONADORES DE SINALSÉRIE FPS
Série FPS-I
Possibilidade de instalação redundante;
Substituição a quente;
Terminador incluso;
Instalação em área segura ouZona 2;
Alarme de falha.
![Page 27: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/27.jpg)
27
CONDICIONADORES DE SINALSÉRIE FPSCONDICIONADORES DE SINALSÉRIE FPS
SÉRIE FPS-D / DT
Possibilidade de instalaçãoRedundante;
Substituição a quente;
Terminador incluso;
Instalação em área segura ouZona 2;
2 segmentos FieldBus ;
Alarme de falha.
![Page 28: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/28.jpg)
28
CONDICIONADORES DE SINALSÉRIE 5995CONDICIONADORES DE SINALSÉRIE 5995
MODELO 5995 USO GERAL EM REDES FOUNDATION FIELDBUS
CORRENTE MÁXIMA 350 mA
![Page 29: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/29.jpg)
29
CONDICIONADORES DE SINAL SÉRIE 5053 CONDICIONADORES DE SINAL SÉRIE 5053
MODÊLO 5053 USO EM SISTEMAS IS
Máximo 6 instrumentos – 80 mA
![Page 30: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/30.jpg)
30
terminador
Área classificada
terminadorIsolador - condicionador
condicionador
CONDICIONADORES DE SINALMONTAGEM ISCONDICIONADORES DE SINALMONTAGEM IS
D=DEVICES FIELDBUS
![Page 31: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/31.jpg)
31
CONDICIONADORES DE SINAL SISTEMA YOKOGAWACONDICIONADORES DE SINAL SISTEMA YOKOGAWA
Modelo 600A – Yokogawa
• Conexão integrada ao cartão AFL11;
• Montagem em trilho DIN (compacto);
• Suporta fonte de alimentação FISCO ou FNICO;
• Redundante (fontes).
![Page 32: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/32.jpg)
32
CONDICIONADORES DE SINAL CONDICIONADORES DE SINAL SISTEMA YOKOGAWASISTEMA YOKOGAWACONDICIONADORES DE SINAL CONDICIONADORES DE SINAL SISTEMA YOKOGAWASISTEMA YOKOGAWA
Modelo F880 – Yokogawa
• Condicionamento e alimentação redundantes para oito segmentos;
• Próprio para trabalhar com o sistema de controle CENTUM 3000 R3;
• Atende o cartão Fieldbus ALF111;• Diagnóstico on-line;• Montagem em trilho DIN
(compacto);• Canais totalmente isolados;• Suporta fonte de alimentação FISCO
ou FNICO;
![Page 33: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/33.jpg)
33
PRODUTOS
FOUNDATION FIELDBUS
PRODUTOS
FOUNDATION FIELDBUS
![Page 34: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/34.jpg)
34
DISPLAYS
FOUNDATION FIELDBUS
DISPLAYS
FOUNDATION FIELDBUS
![Page 35: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/35.jpg)
35
DISPLAYS - FOUNDATION DISPLAYS - FOUNDATION FIELDBUSFIELDBUSDISPLAYS - FOUNDATION DISPLAYS - FOUNDATION FIELDBUSFIELDBUS
MODELO: BA484DF
•Versões em FOUNDATION fieldbus™ H1 e Profibus PA;
•Monitora até oito variáveis de
processo em Foundation Fieldbus;
•Atende aplicações em geral e IS;
•ATEX Gas & Dust, FM and IEC Ex;
•FISCO;
•Três anos de Garantia;
![Page 36: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/36.jpg)
36
DISPLAYS - FOUNDATION DISPLAYS - FOUNDATION FIELDBUS (CAMPO)FIELDBUS (CAMPO)DISPLAYS - FOUNDATION DISPLAYS - FOUNDATION FIELDBUS (CAMPO)FIELDBUS (CAMPO)
![Page 37: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/37.jpg)
37
DISPLAYS - FOUNDATION DISPLAYS - FOUNDATION FIELDBUS (PAINEL)FIELDBUS (PAINEL)DISPLAYS - FOUNDATION DISPLAYS - FOUNDATION FIELDBUS (PAINEL)FIELDBUS (PAINEL)
![Page 38: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/38.jpg)
38
CONECTORES
FOUNDATION FIELDBUS
CONECTORES
FOUNDATION FIELDBUS
![Page 39: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/39.jpg)
39
INSTALAÇÃO COM CONECTORES INSTALAÇÃO COM CONECTORES DE SPURDE SPURINSTALAÇÃO COM CONECTORES INSTALAÇÃO COM CONECTORES DE SPURDE SPUR
9323-SC Spur Connector - Entity
![Page 40: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/40.jpg)
40
INSTALAÇÃO COM CONECTORES INSTALAÇÃO COM CONECTORES DE SPURDE SPURINSTALAÇÃO COM CONECTORES INSTALAÇÃO COM CONECTORES DE SPURDE SPUR
9321-SCSpur Connector - Entity
![Page 41: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/41.jpg)
41
INSTALAÇÃO COM CONECTORES INSTALAÇÃO COM CONECTORES DE SPURDE SPURINSTALAÇÃO COM CONECTORES INSTALAÇÃO COM CONECTORES DE SPURDE SPUR
9322-SCSpur Connector – EEx ia
![Page 42: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/42.jpg)
42
MEGABLOCKSMEGABLOCKS
![Page 43: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/43.jpg)
43
MEGABLOCKSMEGABLOCKS
E/S segmento
E/S segmento
SPUR’s
![Page 44: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/44.jpg)
44
MEGABLOCKSMEGABLOCKS
![Page 45: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/45.jpg)
45
MEGABLOCKSINSTALAÇÃOMEGABLOCKSINSTALAÇÃO
• Hubs passivos;
• Conexão e desconexão sem perturbar a rede;
• Montagem em trilho DIN;
• Indicação por LED de 9VDC presente (mínimo);
• Proteção contra sobretensão (>39VDC);
• SpurGuard isola curto circuito na derivação ou dispositivo.
![Page 46: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/46.jpg)
46
MEGABLOCKSMEGABLOCKS
MÓDULO IS
![Page 47: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/47.jpg)
47
TERMINADORES
FOUNDATION FIELDBUS
TERMINADORES
FOUNDATION FIELDBUS
![Page 48: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/48.jpg)
48
TERMINADORES FIELDBUSTERMINADORES FIELDBUSTERMINADORES FIELDBUSTERMINADORES FIELDBUS
![Page 49: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/49.jpg)
49
BARREIRAS IS
FOUNDATION FIELDBUS
BARREIRAS IS
FOUNDATION FIELDBUS
![Page 50: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/50.jpg)
50
BARREIRAS ISBARREIRAS ISMODELO: 9301FBMODELO: 9301FBBARREIRAS ISBARREIRAS ISMODELO: 9301FBMODELO: 9301FB
![Page 51: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/51.jpg)
51
BARREIRAS ISBARREIRAS ISMODELO: 9301FBMODELO: 9301FBBARREIRAS ISBARREIRAS ISMODELO: 9301FBMODELO: 9301FB
• Montagem em Zona 1 ou 2;
• Proteção Ex ia II C p/ SPURS;
• Alimentado pelo próprio barramento;
• Terminador integrado
![Page 52: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/52.jpg)
52
BARREIRAS ISBARREIRAS ISMODELO: 9302FBMODELO: 9302FBBARREIRAS ISBARREIRAS ISMODELO: 9302FBMODELO: 9302FB
• Montagem em Zona 1 ou 2;
• Proteção Ex ia II C p/ SPURS;
• Alimentação AC ou DC;
• Terminador integrado;
![Page 53: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/53.jpg)
53
EQUIPAMENTOS DE TESTE
FOUNDATION FIELDBUS
EQUIPAMENTOS DE TESTE
FOUNDATION FIELDBUS
![Page 54: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/54.jpg)
54
EQUIPAMENTOS DE TESTEFBT 4EQUIPAMENTOS DE TESTEFBT 4
MONITORA:
-VERIFICA OPERAÇÃO BÁSICA DA REDE
- ALIMENTAÇÃO
- POLARIDADE
- TRÁFEGO DAS INFORMAÇÕES
NÃO REQUER BATERIA!!!
![Page 55: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/55.jpg)
55
EQUIPAMENTOS DE TESTEFBT 3EQUIPAMENTOS DE TESTEFBT 3
MONITORA:
- LAS- TRÁFEGO DE INFORMAÇÕES- NÚMERO DE DISPOSITIVOS ATIVOS NA REDE- ERROS DE FRAME- NÍVEL DO SINAL- NÍVEL DE RUÍDO- ALIMENTAÇÃO
NÃO REQUER BATERIA!!!
![Page 56: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/56.jpg)
56
EQUIPAMENTOS DE TESTEFBT 5EQUIPAMENTOS DE TESTEFBT 5
-GERA SINAL P/ TESTE DA REDE (ARQUITETURA)
-UTILIZADO COM O FBT-3 PARA MEDIR NÍVEL DO SINAL E RUÍDO
- VERIFICA A FIAÇÃO ANTES DO SISTEMA DE CONTROLE SER INSTALADO
![Page 57: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/57.jpg)
57
• Opera sem prejudicar o funcionamento do barramento;
• Verifica nível de ruído e sinais dos dispositivos presentes na rede fieldbus; • Indica se há curto entre o cabo de sinal e o shield; • Permite que os dados obtidos sejam transferidos para um PC, via porta USB.
LANÇAMENTO
EQUIPAMENTOS DE TESTEFBT 6EQUIPAMENTOS DE TESTEFBT 6
![Page 58: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/58.jpg)
58
TESTES – SISTEMA FFTESTES – SISTEMA FF
![Page 59: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/59.jpg)
59
TESTES – SISTEMA FFTESTES – SISTEMA FF
![Page 60: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/60.jpg)
60
TESTES – SISTEMA FFTESTES – SISTEMA FF
![Page 61: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/61.jpg)
61
TESTES – SISTEMA FFTESTES – SISTEMA FF
![Page 62: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/62.jpg)
62
TESTES – SISTEMA FFTESTES – SISTEMA FF
![Page 63: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/63.jpg)
63
CAIXAS DE JUNÇÃO
FOUNDATION FIELDBUS
CAIXAS DE JUNÇÃO
FOUNDATION FIELDBUS
![Page 64: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/64.jpg)
64
CAIXAS DE JUNÇÃOCAIXAS DE JUNÇÃOCAIXAS DE JUNÇÃOCAIXAS DE JUNÇÃO
![Page 65: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/65.jpg)
65
CAIXAS DE JUNÇÃOCAIXAS DE JUNÇÃOCAIXAS DE JUNÇÃOCAIXAS DE JUNÇÃO
• Grande variedade de tamanhos
• Instalação de 2 até 16 Spur’s
• Instalação em área classificada Zona 1 e Zona 2
• Fácil instalação
• Para até 2 Trunk’s (segmentos)
• Materiais de construção : aço inox e Fibra de vidro
• Certificados de aprovação Europeu (Kema) e Americana (UL)
![Page 66: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/66.jpg)
66
OUTROS PRODUTOS
FOUNDATION FIELDBUS
OUTROS PRODUTOS
FOUNDATION FIELDBUS
![Page 67: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/67.jpg)
67
OUTROS PRODUTOS MTL PARA FIELDBUSOUTROS PRODUTOS MTL PARA FIELDBUS
• Plugs para desconexão no campo com rede energizada • Modelo: MTL 951• Uso em Zonas 1 e 2
![Page 68: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/68.jpg)
68
SOFTWARESSOFTWARESSOFTWARESSOFTWARES
• DIMENSIONAMENTO DA REDE E DE
• CÁLCULO DE BARREIRAS.
![Page 69: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/69.jpg)
69
PROTEÇÃO CONTRA SURTO
FOUNDATION FIELDBUS
PROTEÇÃO CONTRA SURTO
FOUNDATION FIELDBUS
![Page 70: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/70.jpg)
70
PRIMEIRO, INSTRUMENTOS DE PRIMEIRO, INSTRUMENTOS DE CAMPO!CAMPO!
ANÁLISE DA INSTALAÇÃOANÁLISE DA INSTALAÇÃO
![Page 71: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/71.jpg)
71
SEGUNDO, UM SISTEMA SEGUNDO, UM SISTEMA DE CONTROLEDE CONTROLE
ANÁLISE DA INSTALAÇÃOANÁLISE DA INSTALAÇÃO
![Page 72: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/72.jpg)
72
MALHA PROTEGIDA!MALHA PROTEGIDA!
ANÁLISE DA INSTALAÇÃOANÁLISE DA INSTALAÇÃO
![Page 73: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/73.jpg)
73
NENHUM DISPOSITIVO SOZINHO É IDEAL.
UMA COMBINAÇÃO
OU DISPOSITIVO HÍBRIDO
É A MELHOR ALTERNATIVA !!!
DISPOSITIVOS DE PROTEÇÃODISPOSITIVOS DE PROTEÇÃO
![Page 74: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/74.jpg)
74
CIRCUITO HÍBRIDO
1
2
Surto na Entrada
Tubo Descarga Gasosa
Diodos
Surto
3
4
PROTEGIDO
LADO
CAMPO
![Page 75: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/75.jpg)
75
DIODO ZENERSOMENTE
1
2
Surto na Entrada
Diodo
Diodos
Surto
3
4
PROTEGIDO
LADO
ENTRADA
![Page 76: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/76.jpg)
76
TUBO DESCARGA GASOSA SOMENTE
1
2
TDG
Tubo Descarga Gasosa
Surto
3
4
PROTEGIDO
LADO
CAMPO
Surto na Entrada
![Page 77: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/77.jpg)
77
DISPOSITIVO HÍBRIDO
1
2
Surto na Entrada
TDG Diodo Híbrido
Tubo de Descarga Gasosa
Diodos
Surto
3
4
PROTEGIDO
LADO
CAMPO
![Page 78: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/78.jpg)
78
• Protetores de Surto para Instrum. com FieldBus– TP32
• Protetores de Surto para rede FieldBus – FP32
PROTETORES “HÍBRIDOS” PROTETORES “HÍBRIDOS” FOUNDATION FIELDBUSFOUNDATION FIELDBUS
Sala de controle
Trunk
Caixa de junção
![Page 79: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/79.jpg)
79
GARANTIAGARANTIA
A MTL OFERECE
10 ANOS DE GARANTIA
EM TODOS SEUS PROTETORES DE
SURTO
![Page 80: Aselco Ff Isa Es 2006](https://reader033.vdocuments.site/reader033/viewer/2022061115/5464e81bb4af9f34788b4670/html5/thumbnails/80.jpg)
80
OBRIGADO!OBRIGADO!Celso BrancoCelso Branco
Gerente de NegóciosGerente de Negócios(11) 3966-5611(11) 3966-5611
[email protected]@aselco.com.br