API Spec 6A Tensile Test Yield Offset Requirements
Tim HaeberleAPI SC6 2012 Summer Meeting
2GE Confidential and Proprietary Information
GEÓ2010 All Rights Reserved
Background
PROBLEM:• The yield strength acceptance criteria for bodies, bonnets, and
end and outlet connections is limited to the 0,2% offset method yield strength values in Table 6. This is good!
• However, for mandrel hangers it is up to the manufacturer to specify not only the yield strength in MPa (psi), but also the method of determining the yield strength.
• Unfortunately, if the manufacturer does not specify the method of determining the yield strength, methods other than the 0,2% offset method may be used, and these may give higher or lower values than would be obtained if the 0,2% offset method were used.
Need to fix in API version
3GE Confidential and Proprietary Information
GEÓ2010 All Rights Reserved
The Solution
PROPOSED REVISION: • 5.3.5.2 PSL 2 to 4 tensile testing (for mandrel tubing hangers
and casing hangers)“b) test method:
Perform tensile tests at room temperature in accordance with the procedures specified in ISO 6892-1 or ASTM A370. Perform a minimum of one tensile test. The results of the tensile test(s) shall satisfy the manufacturer’s specified requirements. The 0,2% offset method shall be used for determination of the yield strength”.
JUSTIFICATION:• A standardized method of determining the yield strength needs
to be used for mandrel casing and tubing hangers.
4
API Ballot
• Ballot ready for SC6 to approve at the 2012 Summer Meeting for formal balloting
5GE Confidential and Proprietary Information
GEÓ2010 All Rights Reserved
End Of Presentation
6GE Confidential and Proprietary Information
GEÓ2010 All Rights Reserved
Backup Slides
7GE Confidential and Proprietary Information
GEÓ2010 All Rights Reserved
BackgroundCURRENT WORDING• 5.3.5.2 PSL 2 to 4 tensile testing (for mandrel tubing hangers and
casing hangers)“b) test method:
Perform tensile tests at room temperature in accordance with the procedures specified in ISO 6892-1 or ASTM A370.Perform a minimum of one tensile test. The results of the tensile test(s) shall satisfy the manufacturer’s specified requirements.”
• 5.4.2.3 PSL 2 to 4 tensile testing (for bodies, bonnets, and end and outlet connections)
“b) test method:Perform tensile tests at room temperature in accordance with the procedures specified in ISO 6892-1 or ASTM A370.Perform a minimum of one tensile test. The results of the tensile test(s) shall satisfy the applicable requirements of Table 6.”
• API 6A Table 6, column 2 (for bodies, bonnets, and end and outlet connections)“0,2% offset yield strength”.