Download - Adult Cannulae Product Catalog
Adult CannulaeProduct Catalog
0929
4-78
10
/12
www.sorin.commanufactured by:Sorin Group Italia S.r.l.Via Statale 12 Nord, 8641037 Mirandola (MO) ItalyTel.+39 0535 29811Fax +39 0535 [email protected]
A full range of cannulaefor every clinical requirement
Venous CannulaeVenous Two Stage Cannulae 5
Venous Single Stage Cannulae 11Optimized Venous Cannula 17
Aortic CannulaeBent Tip Aortic Cannulae 21Straight Tip Aortic Cannulae 27 Optimized Flow Aortic Cannulae 31 Aortic Wessex Cannulae 36
Femoral Cannulae 41
Cardioplegia Cannulae Antegrade Cardioplegia Cannulae 49
Aortic Root Cannulae 51 Coronary Ostium Perfusion Cannulae 55 Suckers 61
Vents 67
Surgical Accessories 73
Minimally Invasive Cardiac Surgery CannulaeVenous Femoral Cannulae 79Venous Cannulae 80Venous Dilator Kit 81Arterial Cannulae 82Arterial Femoral Cannulae 83
Index
Venous CannulaeSorin Venous Cannulae are intended to be used as connections to the extracorporeal circuit in cardiopulmonary bypass procedures to drain venous blood from the patient.Sorin Group provides Venous Cannulae solutions suitable for all applications: Our Venous Cannulae are available in single stage and two stage confi gurations with an optimized tip to maximize venous return. The tubing in clear and transparent medical grade, no DOP, atossic PVC, is designed to lower elasticity loss during hypothermia.Size and clamp markings are printed on the tubing, and depth markings are printed on the tubing for easy insertion.An optional phospholipids coating is available to help improve biocompatibility. The coated version has a B before the code.Example: V122-32 Not coated BV122-32 Coated
Veno
usC
annu
lae
4
5
Only a single Venous Two Stage Cannula is the best choice for drainage of superior and inferior vena cava. The cannula is seated in such a way that the proximal bullet is inside the right atrium and the distal bullet is inside the inferior vena cava.Sorin Group Two Stage Cannulae have two inlet bullets for venous return at a distance of 7 cm from one another to provide superior venous drainage.
Venous Two Stage Cannulae
6
Venous Two Stage CannulaeWith proximal and distal wire reinforcement, without obturator, without connector.
ReferenceNumber
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
V112-32 32/24 10.7/8.0 44 3/8" 10 yes
V112-40 40/32 13.6/10.7 41 1/2" 10 yes
V112-50 50/36 17.0/12.0 41 1/2" 10 yes
Pre
ssur
e d
rop
(mm
Hg)
Flow (lpm)
7
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
OV112-40 40/32 13.6/10.7 41 1/2" 10 yes
OV112-50 50/36 17.0/12.0 41 1/2" 10 yes
Venous Two Stage CannulaeFlat body with proximal and distal wire reinforcement, with obturator,
without connector.
Pre
ssur
e d
rop
(mm
Hg)
Flow (lpm)
8
Venous Two Stage CannulaeWith proximal and distal wire reinforcement, with obturator, with connector.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
V900-284 36/32 12.0/10.7 47 1/2" 10 yes
V900-99 40/32 13.6/10.7 41 1/2" 10 yes
V900-134 50/36 17.0/12.0 41 1/2" 10 yes
9
Venous Two Stage CannulaWith proximal and distal wire reinforcement, without obturator, with vented
connector.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
V900-19 40/32 13.6/10.7 41 1/2" 10 yes
10
Venous Two Stage CannulaeWith proximal and distal wire reinforcement, without obturator, with connector.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
V900-49 40/32 13.6/10.7 41 1/2" 10 yes
V900-11 50/36 17.0/12.0 41 1/2" 10 yes
11
Sorin Venous Single Stage Cannulae are designed to provide optimal venous drainage with a conical tip to allow a smoother insertion, and a unique central hole on the tip to permit better blood drainage. The Highfl ow Cannula is available with a straight and angled tip and with or without a suture ring.The half-rounded “Lighthouse” tip optimizes venous drainage and lowers the risk of traumatic insertion.
Venous Single Stage Cannulae
12
Venous Single Stage Cannulae“Highflow” cannulae with bullet tip, straight, with wire reinforcement,
without connector and without suture ring.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
V122-24 24 8.0 38 3/8" 10 yes
V122-28 28 9.5 38 3/8" 10 yes
V122-32 32 10.7 38 3/8" 10 yes
V122-34 34 11.3 39 3/8" 10 yes
V122-36 36 12.0 39 3/8" 10 yes
V122-40 40 13.6 39 1/2" 10 yes
V122-50 50 17.0 39 1/2" 10 yes
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
13
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Suture Ring
Available Coated
V900-12 28 9.5 40 3/8" 10 yes yes
V900-62 32 10.7 38 3/8" 10 yes yes
Venous Single Stage Cannulae“Highflow” cannulae with bullet tip, straight, with wire reinforcement,
without connector, with suture ring.
14
Venous Single Stage Cannulae“Highflow” cannulae with bullet tip, 90° angle tip, 75 mm angle segment,
with wire reinforcement, without connector, with suture ring on the straight
segment.
Pre
ssur
e d
rop
(mm
Hg)
Flow (lpm)
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Suture Ring Position
from Angle Segment
(mm)
Qty Per Box
Available Coated
V152-28 28 9.5 38 3/8" 30 10 yes
V152-32 32 10.7 38 3/8" 30 10 yes
V152-36 36 12.0 38 3/8" 30 10 yes
15
Venous Single Stage Cannulae“Highflow” cannulae with bullet tip, 90° angle tip, with wire reinforcement,
3/8 connector site without connector, with suture ring on the straight segment.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Suture Ring Position
from Angle Segment
(mm)
Qty Per Box
Available Coated
V900-183 24 8.0 28 1/4" 18 10 yes
V900-01 28 9.5 38 3/8" 18 10 yes
V900-02 32 10.7 38 3/8" 18 10 yes
16
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
V142-28 28 9.5 40 3/8" 10 yes
V142-32 32 10.7 40 3/8" 10 yes
V142-36 36 12.0 40 3/8" 10 yes
Venous Single Stage Cannulae“Lighthouse” cannulae straight.
Pre
ssur
e d
rop
(mm
Hg)
Flow (lpm)
17
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
V182-29 29 9.6 39 3/8" 10 yes
Optimized Venous CannulaVenous Optiflow cannula inteded to be used for atrial-caval cannulation.
A one-piece 13 cm swirled and grooved tip with multiple side holes improves
the drainage regardless the position of the heart.
19
Aortic CannulaeSorin Aortic Cannulae are intended to be used as connection to the extracorporeal circuit in cardiopulmonary bypass procedures to return the aortic blood from the circuit into the patient blood fl ow path.Sorin Group provides a wide range of solutions to meet clinician needs. Products are available with bent and straight tips with wire and without wire reinforcement, with all connections and optional luer lock for venting.Our Aortic Cannulae are designed to optimize fl ow characteristics, reduce turbulence and minimize pressure loss. The tubing design in clear and transparent, no DOP medical grade PVC has been conceived for a small elasticity loss during hypotermia:
• Size and clamp markings are printed on the tubing• Available with and without wire reinforcement tubing• Includes suture fl ange or collar for better cannula fi xation• Arrow on the suture fl ange shows the direction of the fl ow• 3/8” connection site with tubing connector in PC (polycarbonate)• Female luer lock is available in an up or down position for better air venting • White PE cap with central hole (Ø 0.13mm) is included for air venting during cannula priming
An optional phospholipids coating is available to help improve biocompatibility. The coated version has a B before the code.Example: A282-70A Not coated BA282-70A Coated
Ao
rtic
Can
nula
e
A version B version C version
20
21
Sorin Aortic Cannulae with an arch-shaped outlet for better positioning and centered fl ow inside the aortic arch are available with and without wire reinforcement. The bent tip cannulae includes a suture fl ange for an exact fi xation of the cannula or collar for optimal positioning of the cannulae after insertion.
Bent Tip Aortic Cannulae
22
Reference Number
Tubing Connector with Female Luer
Lock
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
A211-45A Up 14 4.5 23 1/4" 10 no
A211-45B Down 14 4.5 23 1/4" 10 no
A211-45C No Luer Lock 14 4.5 23 1/4" 10 no
A211-52A Up 16 5.2 23 3/8" 10 no
A211-52B Down 16 5.2 23 3/8" 10 no
A211-52C No Luer Lock 16 5.2 23 3/8" 10 no
A211-65A Up 20 6.5 24 3/8" 10 no
A211-65B Down 20 6.5 24 3/8" 10 no
A211-65C No Luer Lock 20 6.5 24 3/8" 10 no
A211-73A Up 22 7.3 24 3/8" 10 no
A211-73B Down 22 7.3 24 3/8" 10 no
A211-73C No Luer Lock 22 7.3 24 3/8" 10 no
A211-80A Up 24 8.0 24 3/8" 10 no
A211-80B Down 24 8.0 24 3/8" 10 no
A211-80C No Luer Lock 24 8.0 24 3/8" 10 no
A900-34 90° From Tip 24 8.0 24 3/8" 10 no
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
Bent Tip Aortic Cannulae90° bent tip with suture flange, without wire reinforcement.
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0
23
Reference Number
Tubing Connector with Female Luer
Lock
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
A212-45A Up 14 4.5 23 1/4" 10 no
A212-45B Down 14 4.5 23 1/4" 10 no
A212-45C No Luer Lock 14 4.5 23 1/4" 10 no
A212-52A Up 16 5.2 23 3/8" 10 no
A212-52B Down 16 5.2 23 3/8" 10 no
A212-52C No Luer Lock 16 5.2 23 3/8" 10 no
A212-65A Up 20 6.5 23 3/8" 10 no
A212-65B Down 20 6.5 23 3/8" 10 no
A212-65C No Luer Lock 20 6.5 23 3/8" 10 no
A212-73A Up 22 7.3 23 3/8" 10 no
A212-73B Down 22 7.3 23 3/8" 10 no
A212-73C No Luer Lock 22 7.3 23 3/8" 10 no
A212-80A Up 24 8.0 24 3/8" 10 no
A212-80B Down 24 8.0 24 3/8" 10 no
A212-80C No Luer Lock 24 8.0 24 3/8" 10 no
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
Bent Tip Aortic Cannulae90° bent tip with suture flange, with wire reinforcement.
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0
24
Bent Tip Aortic Cannula90° bent tip with suture flange, with wire reinforcement.
Reference Number
Tubing Connector with Female Luer
Lock
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
A900-23 Up 20 6.5 38 3/8" 10 no
25
Bent Tip Aortic Cannulae90° bent tip with collar without wire reinforcement.
Reference Number
Tubing Connector with Female Luer
Lock
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
A221-45A Up 14 4.5 23 1/4" 10 No
A221-45B Down 14 4.5 23 1/4" 10 No
A221-45C No Luer Lock 14 4.5 23 1/4" 10 No
A221-52A Up 16 5.2 23 3/8" 10 No
A221-52B Down 16 5.2 23 3/8" 10 No
A221-52C No Luer Lock 16 5.2 23 3/8" 10 No
A221-65A Up 20 6.5 24 3/8" 10 No
A221-65B Down 20 6.5 24 3/8" 10 No
A221-65C No Luer Lock 20 6.5 24 3/8" 10 No
A221-80A Up 24 8.0 24 3/8" 10 No
A221-80B Down 24 8.0 24 3/8" 10 No
A221-80C No Luer Lock 24 8.0 24 3/8" 10 No
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0
26
Bent Tip Aortic Cannulae90° bent tip with collar, with wire reinforcement.
Reference Number
Tubing Connector with Female Luer
Lock
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
A222-45A Up 14 4.5 23 1/4" 10 no
A222-45B Down 14 4.5 23 1/4" 10 no
A222-45C No Luer Lock 14 4.5 23 1/4" 10 no
A222-52A Up 16 5.2 23 3/8" 10 no
A222-52B Down 16 5.2 23 3/8" 10 no
A222-52C No Luer Lock 16 5.2 23 3/8" 10 no
A222-65A Up 20 6.5 23 3/8" 10 no
A222-65B Down 20 6.5 23 3/8" 10 no
A222-65C No Luer Lock 20 6.5 23 3/8" 10 no
A222-80A Up 24 8.0 24 3/8" 10 no
A222-80B Down 24 8.0 24 3/8" 10 no
A222-80C No Luer Lock 24 8.0 24 3/8" 10 no
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
27
Sorin Aortic Cannulae with a straight tip and a short straight tip allow for a high fl ow rate and low resistance, as well as easy handling during insertion. They are available with and without wire reinforcement.
Straight Tip Aortic Cannulae
28
Straight Tip Aortic CannulaeWith collar, without wire reinforcement.
Reference Number
Tubing Connector with Female Luer
Lock
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
A231-52A Up 16 5.2 24 3/8" 10 no
A231-52B Down 16 5.2 24 3/8" 10 no
A231-52C No Luer Lock 16 5.2 24 3/8" 10 no
A231-65A Up 20 6.5 24 3/8" 10 no
A231-65B Down 20 6.5 24 3/8" 10 no
A231-65C No Luer Lock 20 6.5 24 3/8" 10 no
A231-80A Up 24 8.0 24 3/8" 10 no
A231-80B Down 24 8.0 24 3/8" 10 no
A231-80C No Luer Lock 24 8.0 24 3/8" 10 no
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0
29
Straight Tip Aortic CannulaeWith collar, with wire reinforcement.
Reference Number
Tubing Connector with Female Luer
Lock
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
A232-45A Up 14 4.5 23 1/4" 10 no
A232-45B Down 14 4.5 23 1/4" 10 no
A232-45C No Luer Lock 14 4.5 23 1/4" 10 no
A232-52A Up 16 5.2 23 3/8" 10 no
A232-52B Down 16 5.2 23 3/8” 10 no
A232-52C No Luer Lock 16 5.2 23 3/8” 10 no
A232-65A Up 20 6.5 24 3/8” 10 no
A232-65B Down 20 6.5 24 3/8” 10 no
A232-65C No Luer Lock 20 6.5 24 3/8” 10 no
A232-80A Up 24 8.0 24 3/8” 10 no
A232-80B Down 24 8.0 24 3/8” 10 no
A232-80C No Luer Lock 24 8.0 24 3/8” 10 no
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0
30
Straight Tip Aortic CannulaeWith double collar, with wire reinforcement.
Reference Number
Tubing Connector with Female Luer
Lock
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
A262-65A Up 20 6.5 24 3/8" 10 no
A262-65B Down 20 6.5 24 3/8" 10 no
A262-65C No Luer Lock 20 6.5 24 3/8" 10 no
A262-80A Up 24 8.0 24 3/8" 10 no
A262-80B Down 24 8.0 24 3/8" 10 no
A262-80C No Luer Lock 24 8.0 24 3/8" 10 no
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0
31
Sorin Optifl ow Cannulae include a three-dimensional tip for better dispersion of the fl ow in the blood path, improving the hemodynamic fl ow in the aorta. This unique feature provides a native-like blood fl ow and avoids the so-called jet stream; thereby, reducing the risk of plaque dislodgment.Optifl ow is available in 21 and 24 FR with or without wire reinforcement and an optional luer lock for air venting.
Optimized Flow Aortic Cannulae
32
Optimized Flow Aortic CannulaeBent tip without wire reinforcement.
Reference Number
Tubing Connector with Female Luer
Lock
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
A281-70A Up 21 7.0 25 3/8" 10 yes
A281-70B Down 21 7.0 25 3/8" 10 yes
A281-70C No Luer Lock 21 7.0 25 3/8" 10 yes
A281-80A Up 24 8.0 25 3/8" 10 yes
A281-80B Down 24 8.0 25 3/8" 10 yes
A281-80C No Luer Lock 24 8.0 25 3/8" 10 yes
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
33
Optimized Flow Aortic CannulaeBent tip with wire reinforcement.
Reference Number
Tubing Connector with Female Luer
Lock
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
A282-70A Up 21 7.0 24 3/8" 10 yes
A282-70B Down 21 7.0 24 3/8" 10 yes
A282-70C No Luer Lock 21 7.0 24 3/8" 10 yes
A282-80A Up 24 8.0 25 3/8" 10 yes
A282-80B Down 24 8.0 25 3/8" 10 yes
A282-80C No Luer Lock 24 8.0 25 3/8" 10 yes
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
34
Optimized Flow Aortic CannulaeStraight tip without wire reinforcement.
Reference Number
Tubing Connector with Female Luer
Lock
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
A291-70A Up 21 7.0 24 3/8" 10 yes
A291-70B Down 21 7.0 24 3/8" 10 yes
A291-70C No Luer Lock 21 7.0 24 3/8" 10 yes
A291-80A Up 24 8.0 24 3/8" 10 yes
A291-80B Down 24 8.0 24 3/8" 10 yes
A291-80C No Luer Lock 24 8.0 24 3/8" 10 yes
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
7.0
8.0
8.0
9.0
35
Optimized Flow Aortic CannulaeStraight tip with wire reinforcement.
Reference Number
Tubing Connector with Female Luer
Lock
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
A292-70A Up 21 7.0 24 3/8" 10 yes
A292-70B Down 21 7.0 24 3/8" 10 yes
A292-70C No Luer Lock 21 7.0 24 3/8" 10 yes
A292-80A Up 24 8.0 24 3/8" 10 yes
A292-80B Down 24 8.0 24 3/8" 10 yes
A292-80C No Luer Lock 24 8.0 24 3/8" 10 yes
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
7.0
8.0
8.0
9.0
37
Sorin Wessex Cannulae include clear and transparent, medical grade no DOP PVC tubing are atossic with low elasticity during hypothermia.These cannulae have a straight tip with optional side holes, all without wire reinforcement.
Aortic Wessex Cannulae
Straight, without wire reinforcement.
Aortic Wessex Cannulae
Reference Number
Outer Diameter
(Fr)
Side Holes
Effective Length (cm)
Connection Site
Suture Ring
Qty Per Box
Available Coated
72600050 24 no 18 3/8" yes 10 yes
72600030 26 yes 25 3/8" yes 10 yes
72600008 26 no 25 3/8" yes 10 yes
72600009 26 no 30 3/8" yes 10 yes
Femoral Cannulae
Femoral Cannulae are expanding the Sorin Group offering of extracorporeal cannulation with Arterial and Venous Cannulae intended to cannulate femoral vessels.FA and FV series made with wire-reinforced polyurethane tubing, characterized by a very thin wall thickness, with an introducer, moveable suture ring, optional side holes and without a tubing connector.Wall thickness vs. internal lumen ratio is optimized in order to obtain the highest fl ow with the smallest anatomical footprint.The FA and FV cannulae can be inserted either via surgical way or via percoutaneous way, with the use of the dedicated Seldinger kit.An optional phospholipids coating is available to help improve biocompatibility. The coated version has a B before the code.Example: FA-119 Not coated BFA-119 Coated
Fem
ora
lC
annu
lae
Femoral Cannulae
42
Venous Femoral CannulaePolyurethane cannula with side holes, with suture ring, with introducer.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Introducer Introducer Length (cm)
Qty Per Box
Available Coated
FV-319 19 6.3 55 3/8" 16 80 3 yes
FV-323 23 7.7 60 3/8" 20 80 3 yes
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
43
Arterial Femoral CannulaePolyurethane with suture ring, with introducer.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Side Holes
Connection Site
Introducer Introducer Length (cm)
Qty Per Box
Available Coated
FA-119 19 6.3 20 no 3/8" 16 40 10 yes
FA-219 19 6.3 20 yes 3/8" 16 40 10 yes
FA-121 21 7.0 20 no 3/8" 18 40 10 yes
FA-221 21 7.0 20 yes 3/8" 18 40 10 yes
FA-223 23 7.7 20 yes 3/8" 20 40 10 yes
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
44
Seldinger Insertion Sets
Reference Number
Description Guidewire Length (cm)
Dilators (Fr)
Needle Gauge
Scalpel Syringe (ml)
Qty Per Box
SIS-060 Seldinger insertion set for arterial
60 8, 12, 14, 16, 20
18 yes 10 2
SIS-150 Seldinger insertion set for venous
150 8, 12, 14, 16, 20
18 yes 10 2
For percutaneous femoral cannulation.
45
Venous Femoral CannulaeWith wire reinforcement and silicone introducer.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box
Available Coated
V172-22 22 7.3 67 3/8" - 1/2" 3 yes
V172-28 28 9.5 87 1/2" 3 yes
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
46
Arterial Femoral CannulaeWith long, flexible, straight tip, with wire reinforcement.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site Qty Per Box
Available Coated
A242-55B 17 5.5 25 3/8" with female luer lock 10 yes
A242-75B 23 7.5 26 3/8" with female luer lock 10 yes
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
47
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site Qty Per Box
Available Coated
A252-45B 14 4.5 22 1/4" with female luer lock down 10 no
A252-52E 16 5.2 22 3/8" with female luer lock down 10 no
A252-60E 18 6.0 22 3/8" with female luer lock down 10 no
A252-65E 20 6.5 22 3/8" with female luer lock down 10 no
A252-70E 21 7.0 22 3/8" with female luer lock down 10 no
Arterial Femoral CannulaeWith straight tip and tapered collar, without introducer.
Flow (lpm)
Pre
sssu
re d
rop
(mm
Hg)
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0
48
49
Cardioplegia CannulaeSorin Cardioplegia Cannulae are intended to deliver cardioplegia solutions and myocardial protection during aortic X-clamp.Sorin Group offers a wide range of Cardioplegia Cannulae suitable for antegrade and retrograde technique. These cannulae are designed to protect your patients during on-pump cardiac surgery by maximizing myocardial protection.An optional phospholipids coating is available to help improve biocompatibility. The coated version has a B before the code.Example: R502-15 Not coated BR502-15 Coated C
ard
iop
leg
iaC
annu
lae
1-4” tubing connector female luer lock
50
51
Sorin Antegrade Cannulae are designed to deliver cardioplegia solutions to the heart via the coronary ostia in the normal direction of blood fl ow (antegrade perfusion). Sorin Group offers both aortic root cannulae and coronary ostium cannulae. Aortic root cannulae infuse the cardioplegia solution directly into the aortic root near the aortic valve, while the coronary ostium cannulae are held on or placed in the coronary ostia.
Sorin Aortic Root Cannulae are intended for delivery of cardioplegia solutions for rapid and secure perfusion of the coronary arteries during cardiopulmonary surgeries.They are made with a stainless steel needle and a fl exible, fl anged PVC tip, with a female luer lock connector and with or without a vent line.
• Size printed on the tubing• Suture fl ange facilitates the fi xing of the cannula
An optional phospholipids coating is available to help improve biocompatibility. The coated version has a B before the code.Example: R501-15 Not coated BR501-15 Coated
Antegrade Cardioplegia Cannulae
Aortic Root Cannulae
52
Aortic Root CannulaeWith female luer lock.
Reference Number
Outer Diameter Needle
(Fr)
Outer DiameterNeedle (mm)
Outer Diameter Needle (Gauge)
Outer Diameter
Tip (mm)
Effective Length (cm)
Connection Site Qty Per Box
Available Coated
R501-15 4.5 1.5 17 3.1 13 female luer lock connector 10 yes
R501-20 6.0 2.0 14 3.7 13 female luer lock connector 10 yes
R501-26 8.0 2.6 12 4.0 13 female luer lock connector 10 yes
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
53
Aortic Root CannulaeVent line with 1/4” tubing connector.
Reference Number
Outer Diameter Needle
(Fr)
Outer DiameterNeedle (mm)
Outer Diameter Needle (Gauge)
Outer Diameter
Tip (mm)
Effective Length (cm)
Connection Site
Connection Site
Qty Per Box
Available Coated
R502-15 4.5 1.5 17 3.1 13 female luer lock
connector
1/4" tubing connector
10 yes
R502-20 6 2 14 3.7 13 female luer lock
connector
1/4" tubing connector
10 yes
R502-26 8 2.6 12 4.0 13 female luer lock
connector
1/4" tubing connector
10 yes
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
Reference Number
Outer Diameter Needle
(Fr)
Outer Diameter Needle (mm)
Outer Diameter Needle (Gauge)
Outer Diameter
Tip (mm)
Effective Length (cm)
Connection Cardioplegia
Site
Connection Vent Site
Qty Per Box
Available Coated
R900-05 4.5 1.5 17 3.1 13 female luer lock
connector
1/4" barbed connector with safety
10 yes
R900-06 6.0 2.0 14 3.7 13 female luer lock
connector
1/4" barbed connector with safety
10 yes
R900-07 8.0 2.6 12 4.0 13 female luer lock
connector
1/4" barbed connector with safety
10 yes
54
Aortic Root CannulaeVent line with 1/4” tubing connector and overpressure safety valve.
Sorin Coronary Perfusion Cannulae are intended to be used to cannulate the
coronary ostium and to deliver cardioplegic solutions during cardiopulmonary surgery.
They are available with stainless steel or PVC tubing and a silicon tip to reduce the
sensitivity to cold fl uid and ensure smooth insertion of the cannula.
The tip is angled at 90° or 135° to easily reach the right and left ostia.
The uniquely-designed soft silicone, 3D tip prevents the cannula from being inserted
too deeply in the coronary ostia and ensures homogeneous perfusion of the
cardioplegic solution, thus reducing the risk of myocardial infarction.
Coronary Ostium Perfusion Cannulae
56
Coronary Ostium Perfusion CannulaeStainless steel tube, 90° tip angle.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site Qty Per Box
Available Coated
P606-30 9 3.0 15 1/4" tubing connector 10 yes
P606-35 11 3.5 15 1/4" tubing connector 10 yes
P606-40 12 4.0 15 1/4" tubing connector 10 yes
P616-30 9 3.0 15 female luer lock connector 10 yes
P616-35 11 3.5 15 female luer lock connector 10 yes
P616-40 12 4.0 15 female luer lock connector 10 yes
P616-45 14 4.5 15 female luer lock connector 10 yes
P616-50 15 5.0 15 female luer lock connector 10 yes
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
57
Coronary Ostium Perfusion CannulaeStainless steel tube, 135° tip angle.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site Qty Per Box
Available Coated
P608-30 9 3.0 14 1/4" tubing connector 10 yes
P608-35 11 3.5 14 1/4" tubing connector 10 yes
P608-40 12 4.0 14 1/4" tubing connector 10 yes
P618-30 9 3.0 14 female luer lock connector 10 yes
P618-35 11 3.5 14 female luer lock connector 10 yes
P618-40 12 4.0 15 female luer lock connector 10 yes
P618-45 14 4.5 15 female luer lock connector 10 yes
P618-50 15 5.0 15 female luer lock connector 10 yes
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
58
Coronary Ostium Perfusion CannulaeWith flexible plastic tube, 135° tip angle.
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site Qty Per Box
Available Coated
P617-30 9 3.0 27 female luer lock connector 10 yes
P617-35 11 3.5 27 female luer lock connector 10 yes
P617-40 12 4.0 27 female luer lock connector 10 yes
P617-45 14 4.5 27 female luer lock connector 10 yes
59
Coronary Ostium Perfusion Cannulae
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site Qty Per Box
Available Coated
P602-40 12 4.0 15 1/4" tubing connector 10 yes
P602-50 15 5.0 15 1/4" tubing connector 10 yes
P612-40 12 4.0 15 female luer lock connector 10 yes
P612-50 15 5.0 15 female luer lock connector 10 yes
3D stainless steel tube, 90° tip angle.
Flow (lpm)
Pre
ssur
e d
rop
(mm
Hg)
60
Coronary Ostium Perfusion Cannulae3D stainless steel tube, 135° tip angle.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site Qty Per Box
Available Coated
P604-40 12 4.0 15 1/4" tubing connector 10 yes
P604-50 15 5.0 15 1/4" tubing connector 10 yes
P614-40 12 4.0 15 female luer lock connector 10 yes
P614-50 15 5.0 15 female luer lock connector 10 yes
SuckersSorin Group offers intracardiac suction devices to remove excess fl uid from the surgical fi eld. These are available with ergonomic plastic grip or fl exible tubing.The plastic ergonomic handling version is available in two different confi gurations according to the tip design:
• fl uted tip • “no block” tip top to avoid tissue damage
An optional phospholipids coating is available to help improve biocompatibility. The coated version has a B before the code.Example: S331-70 Not coated BS331-704 Coated
Suc
kers
62
Suckers
64
Intracardiac Suckers With fluted tip and flexible tubing.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Connection Site
Qty Per Box Available Coated
S331-70 21 7.0 1/4" 10 yes
72600104 18 6.0 1/4" 10 yes
65
Intracardiac Suckers With fluted tip and rigid tubing.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Connection Site
Qty Per Box Available Coated
S351-70 21 7.0 1/4" 10 yes
S900-17 21 7.0 1/4" 5 (2 pieces per package)
yes
66
Intracardiac Sucker With “no block” tip and rigid tubing.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Connection Site
Qty Per Box Available Coated
S352-80 24 8.0 1/4" 10 yes
67
Vents
Sorin Group offers left ventricle and left atrium vent cannulae with side holes to improve the venting of the heart. They include an adjustable stylet with an easy-to-use lock mechanism which facilitates cannula insertion.An optional phospholipids coating is available to help improve biocompatibility. The coated version has a B before the code.Example: W420-62 Not coated BW420-62 Coated
Vent
s
68
Vents
70
VentsLeft ventricle vents.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box Available Coated
W410-62 19 6.2 30 1/4" 10 yes
W900-171 19 6.2 30 1/4" 10 yes
71
VentsLeft atrium vents.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Connection Site
Qty Per Box Available Coated
W420-62 19 6.2 30 1/4" 10 yes
72
Surgical Accessories
Sur
gic
alA
cces
sori
es
74
Surgical Accessories
76
Reference Number Outer Diameter (mm)
Effective Length (cm)
Qty per Package
Package per Box
72600204 6.0 18 2 10
72600211 6.0 18 2 10
72600109 7.5 30 2 10
72600206 9.5 18 2 10
72600207 2x9.5 ; 5x4.0 18 7 10
72600217 6.0 19 4 10
Surgical AccessoriesSnuggers.
Minimally Invasive Cardiac Surgery Cannulae
Specifi cally designed cannulae for minimally invasive cardiac surgery provide optimal blood fl ow at the smallest possible size. Sorin Minimally Invasive Cardiac Surgery Cannulae facilitate femoral and direct cannulation of vessels.
Min
imal
lyIn
vasi
ve
78
Venous Femoral CannulaeSorin RAP Venous Cannulae for femoral, venous cannulation provide
maximum fl ow with minimum outside diameter and exceptional venous
drainage, especially for vacuum assistance.
Reference Number
Outer Diameter (Fr)
Outer Diameter (mm)
Effective Length (cm)
Side Holes
Connection Site
Qty Per Box
Available Coated
200-100 22 Fr. Distal / 22 Fr. Proximal
7.3 / 7.3 68.7 yes 1/2" 5 no
200-150 23 Fr. Distal / 25 Fr. Proximal 7.7 / 8.3 72.5 Yes 1/2" 5 no
Pre
ssur
e d
rop
(mm
Hg)
Flow (lpm)
23/25
22/22
80
Venous CannulaHigh venous drainage cannula include a large inlet area for high fl ow rates
when using vacuum-assisted venous drainage. An integrated obturator
with a stylet allows the surgeon to easily cannulate the right atrium through
minimally invasive access.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Side Holes Connection Site Qty Per Box
Available Coated
200-200 23 Fr 7.7 35.6 yes 3/8” barbed connector 5 no
Pre
ssur
e d
rop
(mm
Hg)
Flow (lpm)
81
Vascular Dilator KitThe Sorin Vascular Dilator Kit is intended for use in surgical procedures to aid
in vascular insertion of the cannula via the Seldinger technique.
Reference Number
Dilators Diameter (Fr)
Scalpel Guidewire Needle Qty Per Box
200-120 8, 12, 16, 20 Fr yes 0.035” x 180 cm 18 Ga 1
82
Arterial CannulaFor arterial cannulation, the Sorin Easy-Flow Cannula is specifi cally
designed for direct cannulation with a malleable stylet to improve insertion.
The straight tip with 3D dispersion fl ow reduces the shear stress on the
aortic wall and avoids plaque dislodgment.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Tip Connection Site Qty Per Box
Available Coated
103-300 23 Fr 7.7 35.6 dispersion 3/8” barbed connector 5 no
Pre
ssur
e d
rop
(mm
Hg)
Flow (lpm)
83
Arterial Femoral CannulaThe versatile design of this arterial femoral cannula allows direct aortic
access and provides a high fl ow for good hemodynamic characteristics.
It is assembled in a kit with a 18 Ga needle, two dilatators and a guidewire
for femoral access introduction. Sorin Minimally Invasive Arterial Cannulae
are intended for use as arterial return or venous drainage cannulae.
Reference Number
Outer Diameter
(Fr)
Outer Diameter
(mm)
Effective Length (cm)
Tip Connection Site Seldinger Kit
Qty Per Box
Available Coated
103-310 23 Fr 7.7 35.6 Dispersion 3/8” barbed connector yes 5 no
Pre
ssur
e d
rop
(mm
Hg)
Flow (lpm)
Kit includes:-18 gauge needle- Blade scalpel- 0.035 x 100 cm guidewire- Dilators: 12 Fr. and 20 Fr.
Adult CannulaeProduct Catalog
0929
4-78
10
/12
www.sorin.commanufactured by:Sorin Group Italia S.r.l.Via Statale 12 Nord, 8641037 Mirandola (MO) ItalyTel.+39 0535 29811Fax +39 0535 [email protected]
A full range of cannulaefor every clinical requirement