DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 12:36:48 PM7/23/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3001_revB.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
R.O.W. FENCE
2'' CONDUIT (QTY.)
1'' CONDUIT (1 EA.)
4'' CONDUIT (QTY.)
COMM. PULL BOX (11'' x 17'')
ELEC. PULL BOX (11'' x 17'')
STUB
VAULT (4' x 4' x 4')
3'' CONDUIT (QTY.)
CANOPY
AMBIENT NOISE SENSOR
STROBE LIGHT
COMM. PULL BOX (17"L X 11"W X 12"D)
SPEAKER
NOTES:LEGEND:ABBREVIATIONS:
C
E
V
1
2
ABBREVIATIONS, LEGEND, AND GENERAL NOTES
04/01/03
ACB
A. CARLOS
OR CONFLICTS, THE MOST STRINGENT SHALL APPLY.
AND FEDERAL CODES AND REGULATIONS. IF THERE ARE ANY VARIANCES
CONSTRUCTION SHALL BE IN COMPLIANCE WITH SCRRA, LOCAL, STATE
ES9400 THRU ES9440.
FOR COMMUNICATIONS SHELTER, SEE COMMUNICATIONS STANDARD DRAWINGS
EQUIPMENT.
CONNECTION OF (3) CONDUCTORS (LINE, NEUTRAL, GROUND) TO
PROVIDE 6 FOOT LONG PIGTAIL AT EACH TVM LOCATION TO ALLOW
SIZED FOR LENGTH OF RUN.
EACH TVM LOCATION; SHALL BE XHHW #10 AWG OR #12 AWG
LOCATION. CONDUCTORS TO BE RUN FROM STATION POWER PANEL TO
PROVIDE SEPARATE 120 VAC, 20 AMP CIRCUIT TO EACH TVM
CONDUITS TO BE STUBBED INTO BOTTOM OF JUNCTION BOX.
PROVIDE 12" SEPARATION BETWEEN POWER AND COMMUNICATION CONDUITS.
PRIOR TO ROUGH-IN OF CONDUITS.
REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF PULL BOXES,
ALL CONDUITS SHALL BE PVC MINIMUM 2'-0" BELOW GRADE.
UNLESS NOTED OTHERWISE.
CONDUIT SIZES SHOWN AT STUB-OUTS TYPICAL FOR ENTIRE RUN
9.
8.
7.
6.
5.
4.
3.
2.
1.
LED
LVM
ELEC. PULL BOX (17"L X 11"W X 12"D)
07-10-15 NDP
LIGHT POLE WITH CAMERA / SPEAKER/ LED MESSAGE SIGN
ACA 09-06-12 NDPREVISED ABBREVIATIONS, LEGEND, NOTES AND TITLE
REVISED ABBREVIATIONS AND LEGEND
VIDEO MANAGEMENT SYSTEM
VOLTS ALTERNATING CURRENT
UNINTERRUPTIBLE POWER SUPPLY
TRANSIENT VOLTAGE SUPPRESION SYSTEM
TICKET VENDING MACHINE
TELECOMMUNICATION DEVICE FOR THE DEAF
TELEPHONE
RECOMMENDED STANDARD
REGISTERED JACK
POLYVINYL CHLORIDE CONDUIT
POWER OVER ETHERNET
POWER DISTRIBUTION PANEL
PRIORITY CONTROLLER
PUBLIC ADDRESS
POWER
NETWORK MEDIA PLAYER
MULTI-TRIP TICKET VALIDATOR MACHINE
MULTI MODE FIBER OPTIC
MEDIA CONVERTER
LIGHT EMITTING DIODE VIDEO MONITOR
LIQUID EMITTING DIODE MESSAGE SIGN
KEYBOARD, VIDEO, MOUSE
INTERFACE CONVERTER
HIGH DEFINITION MULTI-MEDIA INTERFACE
FIBER OPTIC PATCH PANEL
FIBER OPTIC
EMERGENCY TELEPHONE
EMERGENCY MANAGEMENT PANEL
EXISTING
DATA ACQUISITION / TELEPHONE
DATA ACQUISITION
CLOSED CIRCUIT TELEVISION AND FIBER OPTIC
COMMUNICATIONS SHELTER
CUSTOMER INFORMATION SYSTEM
CLOSED CIRCUIT TELEVISION
CATEGORY
LED MESSAGE SIGN
LED VIDEO MONITOR
AND GENERAL NOTES
ABBREVIATIONS, LEGEND
METROLINK STATIONS
ES3001
1 OF 1
NTS
3001
B
VMS
VAC
UPS
TVSS
TVM
TDD
T
RS
RJ
PVC
POE
PDP
PC
PA
P
NMP
MTTV
MMFO
MC
LVM
LED
KVM
IC
HDMI
FOPP
FO
ET
EMP
(E)
D/T
DA
C/F
CS
CIS
CCTV
CAT
HC
680'-0" PLATFORM (LIGHT POLES @ 160'-0" O.C. MAX.)
HC
120'-0"
58'-2"
68'-0"
C
C
C
C
C
C
58'-2"
68'-0"
120'-0"
60'-0"
60'-0"
20'-0"160'-0" 160'-0" 160'-0" 160'-0"20'-0"
20'-0"
85'-0"
85'-0"
60'-0"
60'-0"
16'-
0"
16'-
0"
16'-
0"
16'-
0"
160'-0" 160'-0" 160'-0" 160'-0"3'-
0"
3'-
0"
3'-
0"
3'-
0"
19'-
0"
19'-
0"
19'-
0"
19'-
0"
AS IS PRACTICABLE
OR NEAREST TO MINI-HIGH PLATFORM
LOCATED AT CENTER OF PLATFORM
OVERPASS/UNDERPASS TO BE
AS IS PRACTICABLE
OR NEAREST TO MINI-HIGH PLATFORM
LOCATED AT CENTER OF PLATFORM
OVERPASS/UNDERPASS TO BEPLATFORM
MINI-HIGH
PLATFORM
MINI-HIGH
680'-0" PLATFORM (LIGHT POLES @ 160'-0" O.C. MAX.)
5'-4"
3'-6"
VA
RIE
S
3'-6"
4"
8"
C
TACTILE PANEL
PLATFORM
FILL TO TOP OF
WALKWAY BALLAST
RAMP
ASPHALTPLATFORM
END OF
RA
MP
DO
WN
(TYP)
CPUC RAMP
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> CARLOSA Date Plotted: 8:29:25 AM6/7/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3002_revC.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
-
B1 B3 B5
B1 B3 B5
PE
D
XIN
G
TRACK
TRACK
CROSSING
AT GRADE PED
PLATFORM
END OF PLATFORM
END OF
CROSSING
AT GRADE PED
PLATFORM
MINI-HIGH
(TYP)
TO LOS ANGELES
AWAY FROM LOS ANGELES
B1 B3 B5
B1 B3 B5
PE
D
XIN
G
TRACK
TRACK
CROSSING
AT GRADE PED
PLATFORM
END OF PLATFORM
END OF
CROSSING
AT GRADE PED
PLATFORM
MINI-HIGH
(TYP)
TO LOS ANGELES
AWAY FROM LOS ANGELES
BOMBARDIER CARS
ROTEM CARS
EN
D
OF
PL
AT
FO
RM
EN
D
OF
PL
AT
FO
RM
B7
B7
B7
B7
GMF59PHI
GMF59PH
MP36PH
MP36PH
GMF59PHI
GMF59PH
5.
4.
3.
2.
1.
NOTES: NOTES: (CONT.)
AT LEAST 150 FEET BEYOND EACH END.
INTERTRACK FENCE TO EXTEND FULL LENGTH OF PLATFORM AND
OF TRACK.
CANOPIES TO BE SET BACK A MINIMUM OF 14 FEET FROM CENTERLINE
END OF PLATFORM.
MINI-HIGH PLATFORM TO BE CENTERED 60'-0" FROM LOS ANGELES
STANDARD PLATFORM WIDTH TO BE A MINIMUM OF 16 FEET FOR SIDE PLATFORMS.
STANDARD PLATFORM LENGTH TO BE 680 FEET.
MIN.
MIN.
MIN.
MIN.
ES3002
C 1 OF 1
300205/21/08A. CARLOS
ACA 06-29-12 REVISED PLATFORMS AT MINI-HIGH LOCATIONS NDP
(T
YP)
AT
MINI-
HIG
H
SIDE PLATFORMS
METROLINK STATION STANDARDS1" = 30'
RA
MP
UP
CPUC RAMP DETAIL RAMP SECTION
OF TRACK
SCALE: 1" = 1'-0" SCALE: 3" = 1'-0"
RAMP
ASPHALT
(D
EP
TH
VA
RIE
S)
ACB 10/04/16 NDPADDED CPUC RAMP
ES4020..
ON PEDESTRIAN CROSSING SEE SCRRA STANDARD DRAWING
AT OPPOSITE END OF PLATFORM. FOR ADDITIONAL INFORMATION
SHALL BE APPLIED WHEN A PEDESTRIAN CROSSING IS REQUIRED
CRITERIA SHOWN ON THIS DRAWING FOR PEDESTRIAN CROSSING
CRITERIA.
FOR COMMUNICATIONS SHELTER LOCATION SEE SCRRA DESIGN
COMMUNICATIONS SHELTER NOT SHOWN FOR CLARITY.
7.
6.
ACC 05/31/17 REVISED NOTES (NOTE 8 OMITTED) LA
20'160'160'160'160'20'
680' PLATFORM (LIGHT POLES @ 160'-0" O.C. MAX.)
20'160'160'160'160'20'
120'680' PLATFORM (LIGHT POLES @ 160'-0" O.C. MAX.)
120'
58'-2"
68'-0"
58'-2"
68'-0"
C
C
C
C
C
C
85' CAR LENGTH
85' CAR LENGTH
60'
60'
60'
60'
30'
30'
PLATFORM
MINI-HIGH
AS IS PRACTICABLE
OR NEAREST TO MINI-HIGH PLATFORM
LOCATED AT CENTER OF PLATFORM
OVERPASS/UNDERPASS TO BE
OF TRACK VARIES)
(DISTANCE FROM CENTERLINE
FENCING AT EDGE OF R.O.W.
PLATFORM
MINI-HIGH
AS IS PRACTICABLE
OR NEAREST TO MINI-HIGH PLATFORM
LOCATED AT CENTER OF PLATFORM
OVERPASS/UNDERPASS TO BE
OF TRACK VARIES)
(DISTANCE FROM CENTERLINE
FENCING AT EDGE OF R.O.W.
5'-4"
3'-6"
VA
RIE
S
3'-6"
4"
8"
C
TACTILE PANEL
PLATFORM
FILL TO TOP OF
WALKWAY BALLAST
RAMP
ASPHALTPLATFORM
END OF
RA
MP
DO
WN
(TYP)
CPUC RAMP
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> CARLOSA Date Plotted: 8:29:26 AM6/7/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3003_revC.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
B1
B1 B3 B5 PE
D
XIN
G
TRACK
TRACK
CROSSING
AT GRADE PED
PLATFORM
END OF PLATFORM
END OF
CROSSING
AT GRADE PED
PLATFORM
MINI-HIGH
(TYP)
TO LOS ANGELES
AWAY FROM LOS ANGELES
B1
B1 B3 B5 PE
D
XIN
G
TRACK
TRACK
CROSSING
AT GRADE PED
PLATFORM
END OF
PLATFORM
END OF
CROSSING
AT GRADE PED
PLATFORM
MINI-HIGH
(TYP)
TO LOS ANGELES AWAY FROM LOS ANGELES
BOMBARDIER CARS
ROTEM CARS
B7
B7
MP36PH
GMF59PHI
GMF59PH
MP36PH
GMF59PHI
GMF59PH
5.
4.
3.
2.
1.
NOTES: NOTES: (CONT.)
MIN
MIN
CRITERIA.
FOR COMMUNICATIONS SHELTER LOCATION SEE SCRRA DESIGN
COMMUNICATIONS SHELTER NOT SHOWN FOR CLARITY.
OF TRACK.
CANOPIES TO BE SET BACK A MINIMUM OF 14 FEET FROM CENTERLINE
END OF PLATFORM.
MINI-HIGH PLATFORM TO BE CENTERED 60'-0" FROM LOS ANGELES
STANDARD PLATFORM WIDTH TO BE 30'-0" FOR CENTER PLATFORMS.
STANDARD PLATFORM LENGTH TO BE 680 FEET.
ES3003
C 1 OF 1
300305/21/08A. CARLOS
ACA 01/10/13 REVISED MINI-HIGH CONFIGURATION NDP CENTER PLATFORMS
METROLINK STATION STANDARDS1" = 30'
PL
AT
FO
RM
EN
D
OF
PL
AT
FO
RM
EN
D
OF
RA
MP
UP
CPUC RAMP DETAIL RAMP SECTION
OF TRACK
SCALE: 1" = 1'-0" SCALE: 3" = 1'-0"
RAMP
ASPHALT
(D
EP
TH
VA
RIE
S)
ACB 10/04/16 NDPADDED CPUC RAMP
IS RECOMMENDED.
CONSTRUCTION, THE CONFIGURATION SHOWN ON THIS DRAWING
PLATFORM BY SCRRA DIRECTOR OF ENGINEERING AND
IF APPROVAL IS GRANTED FOR CONSTRUCTION OF CENTER
DRAWING ES4032.
INFORMATION ON PEDESTRIAN CROSSING SEE SCRRA STANDARD
REQUIRED AT OPPOSITE END OF PLATFORM. FOR ADDITIONAL
SHALL ALSO BE APPLIED WHEN A PEDESTRIAN CROSSING IS
CRITERIA SHOWN ON THIS DRAWING FOR PEDESTRIAN CROSSING
7.
6.
ACC 05/31/17 REVISED NOTES (NOTE 8 OMITTED) LA
58’-0"
68’-0"
85’-0"
85’-0"85’-0"
60’-0"
35’-4"23’-5"
85’-0"
35’-3 �"23’-6�"
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 9:14:18 AM4/24/2013 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3004_revA.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
NOTES:
GM F59PH LOCOMOTIVE & BOMBARDIER CAR
MP36PH LOCOMOTIVE & ROTEM CARS
MINI HIGH PLATFORM
PARTIAL PLAN @ TYPICAL SIDE PLATFORM
ES3002 AND ES3003.
FOR ADDITIONAL PLATFORM INFORMATION SEE SCRRA STANDARD DRAWINGS
ADDITIONAL LOCOMOTIVE NUMBER GMF59PH NOT SHOWN FOR CLARITY.
2.
1.E
ND
OF
PL
AT
FO
RM
TO LOS ANGELES AWAY FROM LOS ANGELES
ES3004
A 1 OF 1
" = 1’-0"81
3004
LOCOMOTIVE AND CAR ELEVATIONS
05/05/09A. CARLOS
ACA
PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR
PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR
PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR
PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR
EMERGNCY WINDOW
PULL FOR
PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR
PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR
PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR PULL FOR
EMERGNCY WINDOWEMERGNCY WINDOW
PULL FOR
01/09/13 REVISED PARTIAL PLAN AT PLATFORM NDP
5'-
4"8'-
6"
HANDRAIL
PLATFORM
5'-0" 5'-0"
5'-
5"
6'-
0"
7'-
7"
19'-
0"
3'-
0"
2•"
7"
CONC.
STEEL HANDRAIL
1•" DIA. STAINLESSPOLE
CAULK AT BASE OF
OR POLYURETHANE
•" BEAD OF SILICON
NON-SHRINK GROUT
2•" DIA. CORE
WARNING PANELS
DETECTABLE
2' x 4' YELLOW
3'-
4"
12ƒ
"
12ƒ"
4'-8ƒ"8'-6"
8"
2'-7"
1'-
1"
5'-4"
8'-11"
BOLLARDS
HANDRAIL
4"
3'-
0"
4'-
0"
4•" WIDE (PAINTED)
YELLOW STRIPE
WARNING PANELS (TYP. U.O.N.)
2' x 4' YELLOW DETECTABLE
7'-
11"
2'-
7"
2'-
0"
9"
CLEARANCE ENVELOPELINE OF C.P.U.C.
MINI-HIGH RAMP
VERTICAL SURFACES OF
PROVIDE GRAFFITI COATING AT
R5-1 (DO NOT ENTER) SIGN
18"x18" POST MOUNTED MODIFIED
TUBULAR BOLLARDS (TYP)
THREE BRIGHT YELLOW R5-1 (DO NOT ENTER) SIGN
18"x18" POST MOUNTED MODIFIED
PER NOTE 3
MODIFIED SIGN R5-1
STRIPE SEE ES3203-01
1" WIDE BLACK CONTRAST
EDGE OF PLATFORM
(SEE LEGEND)
DETECTABLE WARNING PANELS
2' x 3' BLACK/WHITE
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 9:47:11 AM11/10/2016 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3101-01_revC.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
EL. + 1'-1"
CJ (TYP.)
OF
TR
AC
KC
ES3101-01
C 1 OF 4
310104/01/03A. CARLOS
ACA
SLOPE 1:16
RAMP UP
NOTE:
MINI-HIGH PLATFORM
A
SCALE: ‚" = 1'-0"
AS NOTED
09-10-12 REVISED PLAN ADDED SECTION A NDP
(MIN)
(MIN)
1-SCALE: 3" = 1'-0"
DETAIL
PLATFORM
MINI-HIGH
3.
2.
1.
EN
D
OF
RA
MP
BLACK TILE
WHITE TILE
LEGEND:
MIN.
CTRACK
T. O. RAIL
SECTION A-SCALE: ƒ" = 1'-0"
RAMP UP
-
1
DO NOT
ENTER
OF SIGN 4'-0" FROM PLATFORM LEVEL.
ON POST PER ES5210 WITH THE TOP
18" x 18" SIGN SHALL BE INSTALLED
THE MODIFIED R5-1, "DO NOT ENTER"
HIGH.
WITH TWO ORANGE REFLECTIVE BANDS 42"
WITH FIXED BASE AND YELLOW IN COLOR
BY IMPACT RECOVERY SYSTEMS OR EQUAL
TUBULAR BOLLARDS SHALL BE "TUFF POST"
BE AS PER SCRRA SPECIFICATIONS.
FABRICATION AND INSTALLATION SHALL
MINI-HIGH PLATFORM DESIGN, MATERIAL,
ACB 08-05-13 NDPREVISED NOTES ON PLATFORM PLAN MINI - HIGH PLATFORM DETAILS
C
ACC 10-07-16 NDPREVISED NOTES, "TILES" TO "PANELS"
50’-8"
17’-4"16’-0"17’-4"
6’-
0"
5’-
0"
11’-
0"
33’-4"
16’-0"17’-4"
6’-
0"
5’-
0"
11’-
0"
VA
RIE
S
17’-4"16’-0"17’-4"
3’-
0"
1’-
1"
5’-
0"
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 1:48:56 PM11/27/2012 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3101-02_revA.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
ES3101-02
A 2 OF 4
NTS
3101
MINI - HIGH PLATFORM DETAILS
04/16/01A. CARLOS
ACA
FRONT VIEW
REAR VIEW
MINI-HIGH HANDRAIL PLATFORM SCHEDULES
HANDRAIL
SIDE PLATFORM (DOUBLE RAMP)TYPE 1
SIDE PLATFORM (SINGLE RAMP)TYPE 2
CENTER PLATFORMTYPE 3
06-29-12 REMOVE SECTIONS AND ADDED PLANS & ELEVATIONS NDP
(TYP. OPP.)
HANDRAIL
DETECTABLE WARNING TILE
(T
YP.
OP
P.)
15'-6" 6'-0" 4'-0" 6'-0" 15'-6"
3'-6" 6'-0" 6'-0" 8'-0" 8'-0" 6'-0" 6'-0" 3'-6"
6'-0"3'-0" 3'-0"6'-0" 6'-0" 6'-0"4'-0"6'-0"6'-0"
6'-
0"
7'-
7"
5'-
5"
19'-
0"
3'-
0"
2'-
7"
7'-
11"
5'-
4"
8'-
6"
12'-
11"
1'-
1"
6'-0" 6'-0"4'-0"
5'-
0"
6'-
0"
15'-0"16'-0"15'-0"
6'-0" 6'-0"4'-0"
5'-
0"
6'-
0"
15'-0" 16'-0"
5'-
0"
6'-
0"
15'-0"16'-0"15'-0"
5'-
0"
6'-
0"
VA
RIE
S
11'-
0"
11'-
0"
11'-
0"
11'-
0"
5'-0" 5'-0"
(TYP.)
PLATE WITH NON-SLIP FINISH
3' x 6'-0" STEEL CHECKERED
CONCRETE RAMP UNITS
6'-0" x 11'-0" PRECAST
CONCRETE PLATFORM UNIT
4'-0" x 11'-0" PRECAST REINFORCED
CONCRETE RAMP UNITS
6'-0" x 11'-0" PRECAST
CONCRETE RAMP UNITS
6'-0" x 6'-0" PRECAST
1" THICK (PAINTED)
BLACK CONTRAST STRIPE
EDGE OF PLATFORM
TACTILE WARNING TILE
HANDRAIL
METAL
WARNING PANEL
2' x 4' YELLOW TACTILE
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 9:47:12 AM11/10/2016 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3101-03_revC.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
FRONT VIEW
REAR VIEW
MINI-HIGH PLATFORM
MINI-HIGH HANDRAIL
ES3101-03
C 3 OF 4
310104/01/03A. CARLOS
ACA 06-29-12 NDP
RAMP DNRAMP DN
OF TRACKC
TYPE 1
TYPE 2
TYPE 3
MINI-HIGH SCHEDULESSHALL BE AS PER SCRRA SPECIFICATIONS.
MATERIAL, FABRICATION AND INSTALLATION
PRECAST MINI-HIGH PLATFORM DESIGN,
NOTE:
REVISE DRAWING SCALE, MINI-HIGH PLATFORM HEIGHT
ACB 08-05-13 NDPREVISED CONTRAST STRIPE PRECAST MINI - HIGH PLATFORM
" = 1'-0"41
ACC 10-07-16 NDPREVISED NOTE, "TILE" TO "PANEL"
6"
1'-
2"
6"
•"
4"
4"
2'-
0"
1'-
0"
1'-0"6"
1'-
1"
4"
1'-
4"
1'-
4"
10•"
7•"
2" 1ƒ"1ƒ" 2"
•"
MA
X.
2•
"
1'-
4"
1'-
4"
4"
3'-
0" T
YP.
1'-
4"
1'-
4"
1‚
"1‚
"
SCALE:
PLATE WITH NON-SLIP FINISH3' x 6'-0" STEEL CHECKERED
5'-
0"
6'-
0"
5'-0"
PLATFORM
MINI HIGHTOP OF
2" R.
2" R.
ADHESIVE BED
SIDE OF MINI HIGH
2•" x 7•" x •" PLATE
SMOOTH (TYP.)WELDED GROUND
BELOW STEEL PLATES
" x 3'-0"832" x 2" x
TYPICAL
" x 2'-0"83L 3" x 3" x
PLATFORM
TOP OF MINI HIGH
ANCHOR BOLTS
W/ (2) ƒ" DIA. x 4"
3" x 3" x …" x 2'-0"
THREADED ROD
‡" HOLES FOR †" DIA. x 10"
PLATFORM
STEEL HANDRAIL
1 •" DIA. O.D. STAINLESS
W/ NON-SLIP FINISH3' x 5'-6" STEEL PLATE
PLATFORM
TOP OF MINI HIGH
STEEL HANDRAIL
1 •" DIA. O.D. STAINLESS
DETAILS SEE ES3203-02
FOR ADDITIONAL PANEL
DETECTABLE WARNING PANEL
DETAILS SEE ES3203-02
FOR ADDITIONAL PANEL
DETECTABLE WARNING PANEL
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 9:47:13 AM11/10/2016 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3101-04_revC.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
LEVEL FLOORSLOPE RAMPCLR LANDING
2"R
RAMP UP
8'-6"
BASE PLATE FOR SINGLE POST
DETAIL
NTS
A-
A-
PLATFORM EDGE
MINI HIGH
TYP.
OF TRACKC
T.O. PLATFORM
ES3101-04
C 4 OF 4
NONE
310102/21/07A. CARLOS
ACA
7'-11"
06-29-12 NDP
12'-11"
REVISE PRECAST PLAN & TYPICAL HANDRAIL 2
ACB 08-05-13 NDPREVISE DETAIL NOTES
DETAILS
PRECAST MINI - HIGH PLATFORM
TYPICAL HANDRAIL 2TYPICAL HANDRAIL 1
DETECTABLE WARNING PANEL
PRECAST RAMP ANCHOR ANGLES
ACC 10-07-16 NDPREVISE NOTES
6'-
0"
8"
9'-
0"
5'-4" 9'-6"
16'-0"
14'-0"
LIGHT POLE
CANOPY
INTERTRACK FENCE
PANEL PER ES3203
DETECTABLE WARNING
CONCRETE SLAB
CAST-IN-PLACE
MIN. 6" THICK
FOOTING DETAILS
STANDARD ES5101 FOR
SEE SCRRA ENGINEERING
SEATING AND PEDESTRIAN TRAFFIC
AS NEEDED TO ACCOMMODATE
EXTEND PLATFORM AT CANOPIES
HOT MIX ASPHALT
6" THICK
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 9:47:14 AM11/10/2016 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3201_revA.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
3%
LANDSCAPING
TRACKC
NOTES:
2.
1.
MIN.
(TYP)
AWAY FROM TRACKS
1% (2% MAX) SLOPE
T.O. RAIL
SIDE PLATFORM
(MIN. CLEAR)
(MIN.)
(MIN. CLEAR)
PLATFORM.
STATION FURNITURE (BENCHES, TRASH RECEPTACLES) SHALL BE PLACED AT THE BACK OF THE
BY THE ARCHITECT.
LIGHT POLE AND CANOPY SHOWN AS REFERENCE ONLY ACTUAL DESIGN TO BE DETERMINED
ES3201
A 1 OF 1
NTS
320105/24/07A. CARLOS
ACA TYPICAL SECTIONS
SIDE PLATFORMS
10-07-16 REVISED WARNING PANEL NOTE NDP
5'-4"
8"
14'-0"
30'-0"
9'-
0"
15'-0"
CANOPY
LIGHT POLE
CONCRETE SLABCAST-IN-PLACEMIN. 6" THICK
EDGE FOUNDATIONCAST-IN-PLACE PLATFORM
(TYP)HOT MIX ASPHALT6" THICK
PANEL PER ES3203DETECTABLE WARNING
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 9:47:14 AM11/10/2016 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3202_revB.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
TRACKC
OF PLATFORMC
NOTE:
TRACKC
MIN.
MIN.
MIN.
PLATFORM
1% SLOPE1% SLOPE
TOP OF RAIL
CENTER PLATFORM
DRAWING IS RECOMMENDED.CONSTRUCTION, THE CONFIGURATION SHOWN ON THISPLATFORM BY SCRRA DIRECTOR OF ENGINEERING ANDIF APPROVAL IS GRANTED FOR CONSTRUCTION OF CENTERSHALL BE PLACED AT THE CENTER OF THE PLATFORM.STATION FURNITURE (BENCHES, TRASH RECEPTACLES)
2.
1.
ES3202
B 1 OF 1
NTS
320205/24/07A. CARLOS
ACA 9-21-12 REVISED DETECTABLE WARNING REFERENCE NUMBER NDP TYPICAL SECTIONS
CENTER PLATFORMSACB 10-07-16 NDPREVISED WARNING PANEL NOTE
4'-
0"
EDGE OF PLATFORM
1'-2"4"
1'-2"
2'-0"
4•"
4'-
0"
1'-2"
4"
EDGE OF PLATFORM
8'-6"
5'-4"2'-0"
8'-6"
5'-4"2'-0"
YELLOW STRIPE
4" WIDE
1" WIDE CONTRAST STRIPE
CONCRETE SLAB
CONTRAST STRIPE
1" WIDE BLACK
YELLOW STRIPE
4•" WIDE
YELLOW STRIPE
4" WIDE
CONTRAST STRIPE
1" WIDE BLACK
FACILITIES)
TITLE 24 TRANSPORTATION
CALIFORNIA BUILDING CODE,
PANEL SHALL COMPLY WITH
(DETECTABLE WARNINGPANEL
YELLOW DETECTABLE WARNING
FACILITIES)
TITLE 24 TRANSPORTATION
CALIFORNIA BUILDING CODE,
PANEL SHALL COMPLY WITH
(DETECTABLE WARNINGPANEL
YELLOW DETECTABLE WARNING
PANEL END
DETECTABLE WARNING
STRIPE)
OVER 4•" WIDE YELLOW
(BLOCK LETTERS PAINTED
SPACING: 30 FT. ON CENTER
COLOR: BLACK
PER ES1212
4" HIGH BLOCK LETTERS,
SPACING: 30 FT. ON CENTER
(WHITE OR YELLOW) SHOULD BE USED.)
A CONTRASTING COLOR
(NOTE: IF PLATFORM SURFACE IS DARK,
COLOR: BLACK
PER ES1212
4" HIGH BLOCK LETTERS
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 9:47:15 AM11/10/2016 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3203-01_revC.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
OF TRACK
PL
EA
SE W
AIT B
EHIN
D Y
EL
LO
W LIN
E
C
AA
C 1 OF 2
1" = 1'-0"
320304/16/01A. CARLOS
NOTE:
AT PLATFORM EDGE
DETECTABLE WARNING PANEL
PL
EA
SE W
AIT B
EHIN
D Y
EL
LO
W LIN
E
OF TRACKC
A A
FOR ADDITIONAL INFORMATION AND DETAILSSEE SCRRA STANDARD DRAWING ES3203-02
ES3203-01
ACA 05-31-13 REVISED CONTRAST STRIPE NDP
ACB 07-24-13 NDPADD ALTERNATE STRIPING, DETAILS MOVED TO SHEET 02
PLAN
ALTERNATE - A
STATIONS WITH SCRRA APPROVAL
FOR JOINT AMTRAK - METROLINK
AND MARKING DETAILSDETECTABLE WARNING TILE
SCALE: •" = 1'-0"
ACC 10-07-16 NDPADD ALTERNATE STRIPING, DETAILS MOVED TO SHEET 02
SECTION A-ADETECTABLE WARNING PANEL
5'-4"
8"
„"
•"
„"
‚"
„"
„"
„" EXPANSION JOINT
0.9"
0.45"
0.2
0"
PLATFORM
EDGE OF
(APPROX.)
1.67"
SLAB
CONCRETE
JOINT FILLER
EXPANSION
BACKER ROD
SEALANT WITH
BACKER ROD
SEALANT WITH
WARNING
DETECTABLE
WARNING
DETECTABLE
WARNING
DETECTABLE
WARNING
DETECTABLE
WARNING
DETECTABLE
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 7:39:58 AM11/15/2016 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3203-02_revA.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
TOP OF PLATFORMSLOPE 1°
OF TRACK
ELEVATION
PLATFORM
CONCRETE
PLATFORM
CONCRETE
PLATFORM
CONCRETE
PLATFORM
CONCRETE
C
TRUNCATED DOMERAISED
TOP OF RAIL
BASE DIA
TOP DIA
SCALE: NONESCALE: NONE
CENTER SPACING
2.35" CENTER TO
IN A STAGGERED PATTERNRAISED, TRUNCATED DOMES
A 2 OF 2
1" = 1'-0"
320307/24/13A. CARLOS
ACA
ES3203-02
AND MARKING DETAILSDETECTABLE WARNING TILE
PANEL JOINTS
DETECTABLE WARNING
AT EXPANSION JOINTS
DETECTABLE WARNING PANEL
PANEL END
DETECTABLE WARNING
AT PLATFORM EDGE
DETECTABLE WARNING PANEL
10-07-16 REVISED DETAIL LABELS NDP
1
2
3
4
5
6
7
8
9
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 9:14:20 AM4/24/2013 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3301-01_revA.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
SHEET INDEX
DESCRIPTIONPAGE
LOCATION PLANS
DESIGN DRAWINGS
GENERAL NOTES
ALL TYPESETTING SHALL BE PROVIDED BY SIGN CONTRACTOR.
LETTER SPACING TO BE "NORMAL" SPACING FOR ALL SIGNS EXCEPT AS SPECIFIED
PATTERNS FOR APPROVAL PRIOR TO FABRICATION.
ALL INSTALLATION LOCATIONS & CONDITIONS SHALL BE FIELD VERIFIED PRIOR
TO FABRICATION.
ALL SIGNS SHALL BE INSTALLED AS PER EXISTING/CURRENT CODE REQUIREMENTS
FOR SAFE & SECURE MOUNTING.
SIGN CONTRACTOR SHALL COORDINATE ALL SIGN INSTALLATIONS WITH METROLINK.
SIGN CONTRACTOR SHALL REFER TO SPECIFICATIONS FOR ALL MATERIAL DETAILS &
SPECIFIC INSTRUCTIONS.
SIGN CONTRACTOR SHALL PROVIDE ALL ENGINEERING OF SIGN & GRAPHIC ITEMS
INCLUDING, BUT NOT LIMITED TO, INTERNAL STRUCTURE, ELECTRICAL & MECHANICAL
PARTS, CONCRETE FOOTINGS & APPLICABLE CODES & REGULATIONS. SHOP DRAWINGS
SHALL CARRY THE ENGINEER’S STAMP & BE SIGNED BY A CALIFORNIA REGISTERED
CIVIL ENGINEER.
SIGN CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL SIGNS.
ALL ATTACHMENT DETAILS SHALL BE SHOWN ON SHOP DRAWINGS & DRAWINGS SHALL
ALL EXPOSED SIGN SURFACES, ATTACHMENTS, EDGES & SEAMS SHALL BE PAINTED OR
PORCELAINIZED AS NOTED TO PREVENT RUST.
NO SIGN SHALL BE INSTALLED WITHIN THE PUBLIC UTILITIES COMMISSION CLEARANCE
ENVELOPE. POST, POLES AND SIGNS MUST HAVE A MINIMUM CLEARANCE OF 8’-6" TO
CENTER OF TANGENT TRACK.
ES3303-03
ES3303-02
ES3303-01
ES3302-02
ES3302-01
ES3301-02
ES3301-01
STATION SIGN MENU
STATION SIGN MENU
GRAPHIC STANDARDS
SHEET INDEX AND GENERAL NOTES
SIDE PLATFORM - TYPICAL SIGN LOCATION PLAN
SIDE PLATFORM - TYPICAL SIGN LOCATION PLAN
STATION SITE - TYPICAL SIGN LOCATION PLAN
ACA
04/01/09
3301
1 OF 2A
NTS
ES3301-01
SHEET INDEX AND GENERAL NOTES
A. CARLOS
OTHERWISE. SIGN CONTRACTOR SHALL PROVIDE SCRRA WITH TYPICAL SPACING
BE SUBMITTED TO SCRRA FOR APPROVAL PRIOR TO FABRICATION.
SIGN TYPE 41: PASSENGER INFORMATION TELEPHONE
CENTER PLATFORM - LOCOMOTIVE POSITION MARKER PLAN
SIDE PLATFORMS - LOCOMOTIVE POSITION MARKER PLAN
SIDE PLATFORMS - LOCOMOTIVE POSITION MARKER PLAN
SIDE PLATFORM - TYPICAL SIGN LOCATION PLAN
SIGN TYPE 30.1: NEW TRAIN POSITION MARKER SIGN
SIGN TYPE 30: TRAIN POSITION MARKER SIGN
SIGN TYPE 28.1: DISPLAY CASE - POST MOUNTED (SINGLE-SIDED)
SIGN TYPE 28: DISPLAY CASE - WALL OR POST MOUNTED
SIGN TYPE 27: A.D.A STATION IDENTIFICATION SIGN AT TRACK
SIGN TYPE 26: MAP/INFORMATION KIOSK FREESTANDING
SIGN TYPE 25: A.D.A STATION IDENTIFICATION SIGN (BRAILLE)
SIGN TYPE 24: PEDESTRIAN RESTRICTIVE/INFORMATION SIGN
SIGN TYPE 23: ACCESSIBILITY SIGN
SIGN TYPE 22: CPUC RAILROAD CROSSING SIGN - POST MOUNTED
SIGN TYPE 21: STATION IDENTIFICATION SIGN - LARGE
SIGN TYPE 20: STATION IDENTIFICATION SIGN - SMALL
SIGN TYPE 16: PEDESTRIAN DIRECTIONAL LOOK SIGN - POST MOUNTED
SIGN TYPE 15: PEDESTRIAN DIRECTIONAL SIGN - GATE MOUNTED
SIGN TYPE 14: PEDESTRIAN CROSSING - WARNING SIGN
SIGN TYPE 13: ELEVATOR IDENTIFICATION SIGN - FLAG MOUNTED
SIGN TYPE 12: ELEVATOR DIRECTIONAL SIGN - POLE MOUNTED
SIGN TYPE 11: TRACK DIRECTIONAL SIGN - POLE MOUNTED
SIGN TYPE 7: ACCESSIBLE PARKING INFORMATION SIGN
SIGN TYPE 6: ACCESSIBLE PARKING - IDENTIFICATION SIGN
SIGN TYPE 5: PARKING RESTRICTIVE SIGN - POLE MOUNTED
SIGN TYPE 4: TRAILBLAZER DIRECTIONAL
SIGN TYPE 3: INFORMATION/RESTRICTIVE - EXIT SIGN INSTALLATION DETAILS
SIGN TYPE 3: INFORMATION/RESTRICTIVE - ATTACHMENT DETAILS
SIGN TYPE 3: INFORMATION/RESTRICTIVE - MOUNTING CONDITIONS
SIGN TYPE 3: INFORMATION/RESTRICTIVE - COPY LAYOUTS
SIGN TYPE 2: VEHICULAR DIRECTIONAL - FREESTANDING SIGN
SIGN TYPE 1: PRIMARY IDENTIFICATION MONUMENT SIGN
ES3332
ES3330-06
ES3330-05
ES3330-04
ES3330-03
ES3330-02
ES3330-01
ES3328-02
ES3328-01
ES3327
ES3326
ES3325
ES3324
ES3323
ES3322
ES3321
ES3320
ES3319
ES3318
ES3317
ES3316
ES3315
ES3314
ES3311
ES3310
ES3309
ES3308
ES3307-04
ES3307-03
ES3307-02
ES3307-01
ES3306
ES3305
03-22-13 REVISE SHEET INDEX NDP
COLOR: COOL GRAY
BACKGROUND: WHITE
COLOR: BLACK
COLOR: COOL GRAY
COLOR: TEAL
COPY COLOR: WHITE
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:47:30 AM4/25/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3301-02_revA.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
PROJECT COLORS
PROJECT SYMBOLS
PROJECT LOGO
NOTE: DIGITAL FILES OF METROLINK LOGOTYPE TO BE PROVIDED BY SCRRA
PROJECT TYPOGRAPHY
BLACK
PMS BLACK
WHITE
TYPICAL BRIGHT WHITE
TEAL
PMS 323
ACCESS BLUE
PMS 801
RED
PMS 193
YELLOW
PMS 116
GREEN
PMS 355
PRIMARY SECONDARY WARNING & TRACKS
CROSSING
2. P.U.C. RAIL 4. NO PARKING 5. NO SMOKING 6. TRAIN
7. PARKING 8. ACCESSIBILITY 9. TELEPHONE 10. RESTROOMS 11. BUS 12. TAXI
PMS 542
BLUE
ARROW
1. PROJECT
ENTER
3. DO NOT
PARKING
13. BICYCLE
PARKING
14. MOTORCYCLE
TRACKS
15. DO NOT CROSS
AACA
A. CARLOS 04/01/09
3301
NTS
2 OF 2
ES3301-02
GRAPHIC STANDARDS03-20-17 REVISED LOGO AND COLORS DJM
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz
0123456789
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz
0123456789
BERTOLD AKZIDENZ GROTESK SUPER
BERTOLD AKZIDENZ GROTESK MEDIUM
GRAY
PMS COOL GRAY 10C
SEA GREEN
PMS 318
ORANGE
PMS 1665C
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.03/31/2011
UserName=> carlosa Date Plotted: 2:24:55 PM10/5/2011 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> s:\V8EngStds\3000\ES3302-01.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
SIGN TYPE 1
PRIMARY IDENTIFICATION SIGN -
MONUMENT
SIGN TYPE 2
VEHICULAR DIRECTIONAL SIGN -
FREESTANDING
SIGN TYPE 3
INFORMATION/ RESTRICTIVE SIGN
SIGN TYPE 4
TRAILBLAZER DIRECTIONAL SIGN
SIGN TYPE 5
PARKING RESTRICTIVE SIGN -
POLE MOUNTED
SIGN TYPE 11
TRACK DIRECTIONAL SIGN
SIGN TYPE 12
ELEVATOR DIRECTIONAL SIGN
SIGN TYPE 13
ELEVATOR IDENTIFICATION SIGN -
FLAG MOUNTED
SIGN TYPE 20
STATION IDENTIFICATION SIGN - SMALL
POLE MOUNTED
SIGN TYPE 16
PEDESTRIAN DIRECTIONAL SIGN -
POLE MOUNTED
SIGN TYPE 21
STATION IDENTIFICATION SIGN - LARGE
POLE MOUNTED
SIGN TYPE 6
ACCESSIBLE PARKING
IDENTIFICATION SIGN
SIGN TYPE 7
ACCESSIBLE PARKING INFORMATION SIGN
SIGN TYPE 23
ACCESSIBILITY SIGN
-XXXXREVISIONXX-XX-XXX
A. CARLOS
3302
NTS
1 OF 2
ES3302-01
STATION SIGN MENU
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.03/31/2011
UserName=> carlosa Date Plotted: 2:24:56 PM10/5/2011 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> s:\V8EngStds\3000\ES3302-02.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
SIGN TYPE 26
MAP/ INFO KIOSK
FREESTANDING
SIGN TYPE 27
ADA STATION IDENTIFICATION SIGN
AT TRACK
SIGN TYPE 28
DISPLAY CASE
SIGN TYPE 30
POSITION MARKER &
TRACK IDENTIFICATION SIGN
SIGN TYPE 30.1
LOCOMOTIVE POSITION MARKER
SIGN TYPE 24
PEDESTRIAN RESTRICTIVE/
INFORMATION SIGN
SIGN TYPE 25
A.D.A. STATION
IDENTIFICATION SIGN
-XXXXREVISIONXX-XX-XXX
A. CARLOS
3302
NTS
2 OF 2
ES3302-02
STATION SIGN MENU
SIGN TYPE 41
PASSENGER INFORMATION TELEPHONE
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.03/31/2011
UserName=> carlosa Date Plotted: 2:24:57 PM10/5/2011 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> s:\V8EngStds\3000\ES3303-01.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
PARKING LOT
BUS STOP
PRIMARY
ENTRANCE
PLATFORM
TRACK
ST
RE
ET
ACCESSIBLE
PARKING
SIGNS
VEHICULAR
DIRECTIONAL
SIGN
SITE
IDENTIFICATION
MONUMENT
ACCESSIBLE PARKING
RESTRICTIVE
NO PARKING
LOADING ZONE
SIGNS
METROLINK
PARKING RESTRICTIVE
SIGN
MAP
INFORMATION
KIOSK
6-1
26-1
3-1
7-1
1-1
2-1
5-1
NOT FOR CONSTRUCTION
NOTE:
THIS REPRESENTS A TYPICAL METROLINK STATION
AND IS SHOWN FOR REFERENCE ONLY.
ACTUAL STATIONS MAY VARY FROM THIS PLAN.
PLAN
SCALE: NTS
-XXXXREVISIONXX-XX-XXX
A. CARLOS
3303
NTS
1 OF 3
ES3303-01
TYPICAL SIGN LOCATION PLAN
STATION SITE
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.03/31/2011
UserName=> carlosa Date Plotted: 2:24:58 PM10/5/2011 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> s:\V8EngStds\3000\ES3303-02.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
PLAN
SCALE: NTS
TRACK
FENCE
TRACK
PLATFORM
PLATFORM
"DO NOT ENTER"
SIGN
24-1
21-1
24-2
21-1
24-4
21-1
24-2
21-1
24-2
21-1
24-4
21-1
24-2
23-1
25-1
23-1
25-1
"PLEASE
PURCHASE
TICKET"
SIGN
"PLEASE
PURCHASE
TICKET"
SIGN
21-1
24-4
"NO BICYCLING"
SIGN
21-1
24-4
24-1
24-1
24-1
24-1
"DO NOT ENTER"
SIGN
"NO BICYCLING"
SIGN
24-1
24-1
"DO NOT ENTER"
SIGN
23-1
25-1
25-1
25-1
23-1
ADA STATION
IDENTIFICATION
SIGN
ACCESSIBLE RAMP
IDENTIFICATION
SIGN
STATION IDENTIFICATION
SIGN25-1
24-1
"DO NOT ENTER"
SIGN
NOT FOR CONSTRUCTION
NOTE:
THIS REPRESENTS A TYPICAL METROLINK STATION
AND IS SHOWN FOR REFERENCE ONLY.
ACTUAL STATIONS MAY VARY FROM THIS PLAN.
ST
ATIO
N E
NT
RA
NC
E
ST
ATIO
N E
NT
RA
NC
E
-XXXXREVISIONXX-XX-XXX
A. CARLOS
3303
NTS
2 OF 3
ES3303-02
TYPICAL SIGN LOCATION PLAN
SIDE PLATFORM
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.03/31/2011
UserName=> carlosa Date Plotted: 2:24:58 PM10/5/2011 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> s:\V8EngStds\3000\ES3303-03.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
PLAN
SCALE: NTS
TRACK
FENCE
PLATFORM
21-1
24-4
21-1
24-2
21-1
24-4
21-1
24-2
27-1
24-1
24-1
27-1
24-1
25-1
ADA STATION
IDENTIFICATION
SIGN
ACCESSIBLE
RAMP
IDENTIFICATION
SIGN
IDENTIFICATION DECAL
APPLIED TO
TICKET VALIDATOR
STATION IDENTIFICATION SIGN23-1
31-1
25-1
24-1
NOT FOR CONSTRUCTION
NOTE:
THIS REPRESENTS A TYPICAL METROLINK STATION
AND IS SHOWN FOR REFERENCE ONLY.
ACTUAL STATIONS MAY VARY FROM THIS PLAN.
ST
ATIO
N E
NT
RA
NC
E
-XXXXREVISIONXX-XX-XXX
A. CARLOS
3303
NTS
3 OF 3
ES3303-03
TYPICAL SIGN LOCATION PLAN
SIDE PLATFORM
3"
TOP COLOR: WHITE
SIGN CABINET
SMOOTH AND PAINTED COLOR: WHITE
TOP OF POST TO BE FINISHED
1'-0"
C
CC
9'-1"
1'-0" 8'-0" 1'-0"•" •"
1'-
8"
4"
5"
5"2•
"1ƒ
"
3"
2‚
4" 1ƒ"
4"
10•
"
10•" 4"
3"
ENAMEL PANEL
PAN STYLE PORCELAIN
DOUBLE-FACED 2-PARTALUMINUM POST
1'-0" DIA.
STEEL REVEAL
GRADE PLYWOOD PANELS TO PREVENT OIL-CANNING
INTERNAL STRUCTURE AS REQ'D. INSERT MARINE
ELECTRICAL CONDUIT
COPY COLOR: WHITE
LOGO COLOR: WHITE
BACKGROUND COLOR: TEAL
COLOR: WHITE
ALUMINUM POST
REVEAL COLOR: GRAY
FABRICATED ALUMINUM
DEPTH AS REQUIRED
CONCRETE FOOTING TO
LINE COLOR: WHITE
BAR COLOR: ORANGE
•"
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:47:31 AM4/25/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3305_revB.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
BACA
A. CARLOS 04/01/09
3305
1 OF 1
ES3305
B A
C
E
D
05/01/12 REVISED DETAIL "A" AND "D" NDP SIGN TYPE I
PRIMARY IDENTIFICATION MONUMENT SIGN
City Name/
City Name Station
12345
City Name/
12345
ƒ"
RE
VE
AL
ƒ"
RE
VE
AL
&
PO
ST
S
OF
PA
NE
L
SIGN TYPE 1
PRIMARY IDENTIFICATION SIGN - MONUMENT
SIGN CONTRACTOR SHALL ENGINEER FABRICATION & INSTALLATION 1.
OF SIGN STRUCTURE TO SATISFY ALL LOCAL CODES & WIND LOAD FACTORS.
SIGN PANEL TO BE PORCELAIN ENAMEL W/ SMOOTH-FINISHED EDGES & SEAMS; 2.
MARINE GRADE PLYWOOD-FILLED INTERIOR.
ALL FASTENERS SHALL BE PLATED FASTENERS & SHALL BE PAINTED 3.
TO MATCH SIGN FACE.
NOTES:
PLAN SECTION
1 LINE/DOUBLE-FACED
ELEVATION
PLAN
2 LINE/DOUBLE-FACED
ELEVATION
SIDE VIEW
COLOR #1: COOL GRAY
COLOR #2: BLACK
COLOR #3: TEAL
COLOR #1: COOL GRAY
SCALE: 1" = 1'-0"SCALE: 1" = 1'-0"SCALE: •" = 1'-0"
NOT TO SCALE
NOT TO SCALE
SCALE: 1" = 1'-0"
AS NOTED
ACB 03/21/17 DJMREVISED DETAILS A, B, C AND D
C
CC
3"
TOP COLOR: WHITE
SIGN CABINET
SMOOTH AND PAINTED COLOR: WHITE
TOP OF POST TO BE FINISHED
3'-5"
4" 3'-0" 4"•" •"
BACKGROUND COLOR: TEAL
REVEAL COLOR: GRAY
FABRICATED ALUMINUM
DEPTH AS REQUIRED
CONCRETE FOOTING TO
2'-
6"
4'-
0"
4" DIA. POSTS
ES3301-02
LOGO COLORS PER
COLOR: WHITE
PAINTED STEEL POST
3"4‚" 3"
3"
11•
"6ƒ
"
2‡"
5"
5"
COLOR: ORANGE
COPY COLOR: WHITE
GRAPHIC COLOR: BLACK
5" DIA. GRAPHIC
COPY COLOR: WHITE
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:47:32 AM4/25/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3306_revA.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
AACA
A. CARLOS 04/01/09
3306
1 OF 1
ES3306SIGN TYPE 2
FREESTANDING SIGNVEHICULAR DIRECTIONAL
B A
C
D
&
PO
ST
S
OF
PA
NE
L
SIGN CONTRACTOR SHALL ENGINEER FABRICATION & INSTALLATION 1.
OF SIGN STRUCTURE TO SATISFY ALL LOCAL CODES & WIND LOAD FACTORS.
SIGN PANEL TO BE PORCELAIN ENAMEL W/ SMOOTH-FINISHED EDGES & SEAMS; 2.
MARINE GRADE PLYWOOD-FILLED INTERIOR.
ALL FASTENERS SHALL BE PLATED FASTENERS & SHALL BE PAINTED 3.
TO MATCH SIGN FACE.
NOTES:
PLAN SECTION
PLAN
SIDE VIEW
SCALE: 1•" = 1'-0"SCALE: 1•" = 1'-0"NOT TO SCALE
SCALE: 1•" = 1'-0"ƒ"
RE
VE
AL
ƒ"
RE
VE
AL
ELEVATION DOUBLE-FACED
4-1/2" (5" O.D.)
STEEL POST DOUBLE-FACED 2-PART
PAN STYLE PORCELAIN
ENAMEL PANEL
INTERNAL STRUCTURE AS REQ'D.INSERT MARINE GRADE PLYWOOD
PANELS TO PREVENT OIL-CANNING.REVEAL
STEEL
SIGN TYPE 2
VEHICULAR DIRECTIONAL SIGN - FREESTYLE
03-21-17 REVISED SIGN DETAILS DJM
AS NOTED
Parking
1'-0"
C
1'-
6"
"21
2"
211
"21
7
PANEL COLOR: TEAL
(TYPICAL)R = •"
COLOR: WHITEBOTH SIDESOR PAINTED ONCOPY SILKSCREENED
"21
1
"43
"83
11"
"83
41"
"21
1"
43"
211
1"
"43
32"
"43
"21
1
"41
4"21
1 "21
1
"43
"21
11"
"83
4"
432
"21
31"
5"
1"
"21
1
1"
"21
1
"21
1 1"
1"
3"
"43
11"
COLOR: WHITECOPY & SYMBOL
THIS SIGN ONLYBACKGROUND COLOR: RED
"43
2
1"
1"
"2
1
"871
"41
1
(TYP)COLOR: ORANGE
"87
3"87
3
ES3301-02LOGO COLORS PER
3"
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:47:32 AM4/25/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3307-01_revA.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
A
B
AACA
A. CARLOS 04/01/09
3307
NTS
1 OF 4
ES3307-01SIGN TYPE 3
COPY LAYOUTS
INFORMATION / RESTRICTIVE
(TYPICAL)
& COPYOF PANEL
ARE TO BE DOUBLE FACEDALL TRACK NUMBER SIGNS
NOTE:
SIGN TYPE 3
INFORMATION / DIRECTIONAL SIGN
1COPY LAYOUTS TRACK ID SIGN
(SEE ES3307-03 FOR INSTALLATION)
COPY LAYOUTS
6DIRECTIONAL SIGN
(4 COPY LINES)5
DIRECTIONAL SIGN
(3 COPY LINES)4
DIRECTIONAL SIGN
(2 COPY LINES)3
EXIT SIGN
(SEE ES3307-04 FOR INSTALLATION)2
RESTRICTIVE SIGN
NOTES:
DIMENSIONS & NOTES TYPICAL EXCEPT AS NOTED.1.
CONTINUE PAINT COLOR USED ON FRONT SURFACE OF SIGNS TO SIDES. PAINT BACK OF PANEL SOLID WITH DOMINANT COLOR.2.
SEAL SIGNS WITH TRANSPARENT ANTI-GRAFFITI FILM. 3.
SIGN TYPE 3 NUMBERS CHART
3-01 THRU 3-19 3-20 THRU 3-29 3-30 THRU 3-39
TRACK NUMBER /
IDENTIFICATION SIGNS
DIRECTIONAL SIGNSREGULATORY SIGNS
03-22-17 REVISED SIGNS DETAILS DJM
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.03/31/2011
UserName=> carlosa Date Plotted: 2:25:02 PM10/5/2011 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> s:\V8EngStds\3000\ES3307-02.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
ELEVATIONS / MOUNTING CONDITIONSA
WALL MOUNT1 LIGHT POLE MOUNT
(DIRECTIONAL SIGN)
2 LIGHT POLE MOUNT
(TRACK IDENTIFICATION SIGN)
3 FENCE MOUNT4
POST MOUNT
(RESTRICTIVE SIGN)
5 POST MOUNT
(RESTRICTIVE SIGN)
6 FLAG MOUNT - TALL
(EXIT SIGN)
7 FLAG MOUNT - SHORT
(EXIT SIGN)
8
C/L OF POST &
SIGN PANEL
SIGN PANEL
(SEE ATTACHMENT
SIGN PANEL
(SEE ATTACHMENT
2" SQ.
PAINTED
STEEL POST
COLOR: WHITE
C/L OF
SIGN PANEL
C/L OF LIGHT
STANDARD / POLE
& SIGN PANEL
SIGN PANEL
SIGN PANEL
FENCE
SIGN
PANEL
(SEE ATTACHMENT
SIGN PANEL
(TOP OF SIGN
TO ALIGN W/
TOP OF FENCE)
PAINTED
TOP PLATE
COLOR: WHITE
PAINTED TOP PLATE
COLOR: WHITE
PAINTED TOP PLATE
COLOR: WHITE
3’-8" +/-
VARIES
1"
SIGN PANEL
FLAG MOUNTED TO POST
(SEE ATTACHMENT DETAILS
NOTE: SIGNS TO POINT AWAY
RIGHT-OF-WAY CLEARANCE
60"
6’-8"
(80")
6’-8"
(80")
6’-8"
(80")
6’-8"
(80")
2" SQ.
PAINTED STEEL POST
COLOR: WHITE
SIGN PANEL
FLAG MOUNTED
TO POLE
(SEE ATTACHMENT WALL
FROM TRACKS TO MAINTAIN
DETAIL 3 ES3307-03)
DETAIL 7 ES3307-03)
2, 3 ES3307-03)
DETAILS 9, 10, 11 ES3307-03)
DETAIL 3 ES3307-03)
-XXXXREVISIONXX-XX-XXX
A. CARLOS
3307
NTS
2 OF 4
ES3307-02SIGN TYPE 3
DETAILS
INFORMATION / RESTRICTIVE SIGN
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:47:32 AM4/25/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3307-03_revA.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
AACA
A. CARLOS 04/01/09
3307
NTS
3 OF 4
ES3307-03SIGN TYPE 3
ATTACHMENT DETAILS
INFORMATION / RESTRICTIVE SIGN
1
2 3 4
65
8
7
11109
ATTACHMENT DETAILSA
H4-D-007 STRAP ON
L-MOUNT BRACKET
STAINLESS STEEL
AS MANUFACTURED
BY WESTERN HIGHWAYS
OR APPROVED EQUAL
TAMPER
PROOF
FASTENER
SIGN PANEL
MOUNTS TO BACK
SIDE OF BRACKET
TAMPER PROOF
FASTENERS
SIGN PANEL
PAINTED GRAY
FABRICATED STEEL BRACKET
1/8" THICK PAINTED ALUMINUM
BACK PANEL MECHANICALLY
ATTACHED TO POST WITH
FLUSH-HEAD SCREWS AS REQ'D.
ATTACHED TO BACK PANEL W/ 3M VHB TAPE
1/8" THICK PAINTED ALUM. SIGN PANEL
AROUND PERIMETER & SILICONE ADHESIVE
AS REQ'D. FOR SAFE & SECURE MOUNTING.
APPLY QUALITY PRIMARY TO ALL PAINTED
SURFACES TO PREVENT ELECTROLYSIS.
TYPICAL, ALL SIGNS.
TAMPERPROOF FASTENERS
BACK PANEL - SAME SIZE AS SIGN PANEL
FENCE/ GATE
FLUSH-HEAD SCREWS AS REQUIRED
SIGN PANELCOLOR: WHITE
PAINTED STEEL BRACKET
LIGHT STANDARD/ POLE
SILICONE
METAL WITH D/F TAPE &
SIGN PANEL ATTACHED TO
METAL SURFACE
INFORMATION / DIRECTIONAL SIGN
ROUND
POLE
FASTENER
HARDSCAPE
EXISTING
HOLE
INTO CORED
POURED
CONCRETE
SIGN POST
AS REQUIRED
FOOTING TO DEPTH
CONCRETE
SIGN POST
HARDSCAPE
EXISTING
CONCRETE ANCHORS
TAMPER PROOF
COLOR: WHITE
FLANGE, WELDED TO POST
PAINTED STEEL
SIGN POST
FLUSH-HEAD CONCRETE ANCHOR
DEPTH AS REQUIRED
EXISTING MASONRY WALL
1/8" PAINTED ALUMINUM
BACK PLATE
SIGN PANEL ATTACHED TO
BACK PLATE WITH VHB TAPE
WALL MOUNT TO MASONRY HARDSCAPE MOUNTING CONDITION
WITH FLANGE
LANDSCAPE MOUNTING
CONDITION
HARDSCAPE MOUNTING CONDITION
CORE AND DRILL
WALL MOUNT TO METAL POLE MOUNT ON EXISTING POLE FENCE MOUNT
FLAG MOUNT TO SQUARE POST FLAG MOUNT TO SQUARE STEEL POST SQUARE POST MOUNT
FLAG MOUNT TO ROUND POLE
SIGN TYPE 3 - TRACK IDENTIFICATION
LIGHT STANDARD / POLE
SIGN PANEL BACK
STAINLESS
STEEL STRAP
ST. STL. STRAPS
@ ROUND POLES
(SEE B ES3307-01)
ST. STL. BRACKETS
@ SQ. POSTS
(SEE B9 ES3307-02)
POLE/POST
COLOR: WHITE
SIGN FACE
STEEL POST
SQUARE POST
SIGN
PANELAPPLICATIONS ONLY
FOR SQUARE POST
OR APPROVED EQUAL
(AMERICAN SIGN BRACKETS)
WING BRACKET #11-11F
SIGN PANEL
SQUARE POST
STAINLESS
STEEL STRAP
ATTACHMENT SCREWS,
QTY. AS REQ'D.
03-22-17 REVISED DETAIL "1" DJM
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.03/31/2011
UserName=> carlosa Date Plotted: 2:25:04 PM10/5/2011 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> s:\V8EngStds\3000\ES3307-04.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
INFORMATION / DIRECTIONAL SIGN
SIGN TYPE 3 - EXIT SIGN
VERSION OF SIGN WITH SIGN PANEL POINTING
PLATFORM EDGE
EXISTING FENCE BEHIND SIGN
2" SQ. PAINTED STL. POST
COLOR: WHITE
FLAG MOUNT - TALL (EXIT SIGN)
A
CLEARANCE
1
AWAY FROM TRACK. (SEE A)
WHERE DISTANCE FROM CENTERLINE OF TRACK2.
TO FENCE IS 10’-2" OR GREATER, INSTALL SHORT
VERSION OF SIGN WITH SIGN PANEL POINTING
TOWARD TRACK. (SEE B)
MINIMUM
DISTANCE
FROM FENCE
PLATFORM
EDGE
POST &
SIGN PANEL
EXISTING FENCE
WHERE FENCE IS LOCATED LESS THAN 10’-2"1.
FROM CENTERLINE OF TRACK, INSTALL TALL 8’-6"
PLATFORM EDGE
2" SQ PAINTED STL. POST
CLEARANCE
2 PLAN
EDGE
PLATFORM
MINIMUM
FROM FENCE
POST &
SIGN PANEL
EXISTING FENCE
EXISTING FENCE
SIGN PANEL
PEDESTRIAN WALKWAY
FLAG MOUNT - SHORT (EXIT SIGN)
SEE NOTE 3
C/L OF TRACK
B
1
SIGN PANEL
8’-6"
DISTANCE
COLOR: WHITE
2 PLAN
C/L OF TRACK
C/L OF TRACK
6’-8"
C/L OF TRACK
ELEVATIONELEVATION
8’-6" CLEARANCE 8’-6" CLEARANCE
SEE NOTE 3
SEE NOTE 4, ES2102.3.
NOTES:
-XXXXREVISIONXX-XX-XXX
A. CARLOS
3307
NTS
4 OF 4
ES3307-04SIGN TYPE 3
EXIT SIGN INSTALLATION DETAILS
INFORMATION / RESTRICTIVE SIGN
3'-0"
3'-
0"
C
5"
10"
10"
"8
52
2"
2"
PAINT TO MATCH PANEL
LAG BOLTS AS REQUIRED
PANEL COLOR: TEAL
LOGO COLOR: WHITE
REFELCTIVE VINYL DIE CUT
ES3301-02
LOGO COLORS PER
6" x 6" WOOD POST
HEAD TO MATCH PANEL FACE
LAG BOLT AS REQUIRED, PAINT
STRAP
STAINLESS STEELEXISTING LIGHT STANDARD
IF REQUIRED FOR STABILITY
ADD ALUMINUM "L" BRACKETS
SIGN PANEL
„" THICK ALUMINUM
REQUIRED PAINTED WHITE
ALUMINUM CHANNEL AS
AS REQUIRED
ATTACHMENT SCREWS
PANEL
SIGN
POST
WOOD
6" x 6"
SIGN PANEL
8'-
0"
STANDARDS
AS PER CALTRANS
OR BREAK-AWAY POST
6" x 6" WOOD POST
VARY)
(CONDITIONS
POLE
EXISTING
SIGN FACE
TO MAINTAIN VERTICAL
SHIM AS REQUIRED
AS REQUIRED
CONCRETE FOOTING
INSTALLER
& APPLIED IN THE FIELD BY
DIRECTION TO BE DETERMINED
ARROW COLOR: ORANGE
REFELCTIVE VINYL DIE CUT
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:47:33 AM4/25/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3308_revA.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
AACA
A. CARLOS 04/01/09
3308
NTS
1 OF 1
ES3308
SIGN TYPE 4
TRAILBLAZER DIRECTIONAL SIGN
LOGO
PANEL, ARROW &
PLAN SECTION - POST MOUNTED
NOTES:
CONTINUE PAINT COLOR USED ON FRONT SURFACE OF SIGNS AROUND EDGES.1.
PAINT BACK SIGN PANEL TEAL.2.
ALL FASTENERS SHALL BE PLATED AND PAINTED TO MATCH SURROUNDING COLOR.3.
4. SEAL SIGN WITH TRANSPARENT ANTI-GRAFFITI FILM.
SIGN TYPE 4
TRAILBLAZER DIRECTIONAL SIGN
(V
ERIF
Y
WIT
H
CIT
Y)
PLAN SECTION - POLE MOUNTED
ELEVATIONS COPY LAYOUT
POST MOUNTED
SIDE VIEW - FRONT VIEW -
POST MOUNTED
FRONT VIEW -
POLE MOUNTED
SIDE VIEW -
POLE MOUNTED
4-1
D
C
B A
1 2 3 4
03-23-17 REVISED COPY LAYOUT "A" AND ELEVATIONS DJM
"2
1"
43
"2
11"
1"
2'-
0"
1'-5"
1"
2"
‡"
1"
2'-
0"
2"
1'-5"
1"
ƒ"
1"
"8
52"
43
1"
ALIGN COPY
BACKGROUND COLOR: TEAL
R = •"
COLOR: WHITE
PAINTED COPY
SILK SCREEN OR
PRIOR TO FABRICATION
VERIFY COPY W/ SCRRA
ALIGN COPY
BACKGROUND COLOR: TEAL
COLOR: WHITE
PAINTED COPY
SILK SCREEN OR
PRIOR TO FABRICATION
VERIFY COPY W/ SCRRA
R = •"
(TYPICAL, ALL SIGNS)
SURFACES TO PREVENT ELECTROLYSIS.
APPLY QUALITY PRIMARY TO ALL PAINTED
AS REQUIRED FOR SAFE & SECURE MOUNTING.
TAPE AROUND PERIMETER & SILICONE ADHESIVE
ATTACHED TO BACK PANEL WITH 3M VHB
„" THICK PAINTED ALUMINUM SIGN PANEL
REQUIRED
FLUSH-HEAD SCREWS AS
ATTACHED TO POST WITH
BACK PANEL MECHANICALLY
„" THICK PAINTED ALUMINUM
BEFORE PAINTING COLOR: WHITE
WELD TO POST AND GRIND SMOOTH
„" PAINTED STEEL TOP PLATE,
C
SIGN PANEL
COLOR: WHITE
STEEL POST
2" SQ. PAINTED
1"
6'-
8"
REQUIRED
FOOTING AS
CONCRETE
1"
LOGO COLOR PER ES3301-02
LOGO COLOR PER ES3301-02
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:47:34 AM4/25/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3309_revA.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
A
D
B
AACA
A. CARLOS 04/01/09
3309
NTS
1 OF 1
ES3309
ALIGN
C
SIGN TYPE 5
POLE MOUNTED
PARKING RESTRICTIVE SIGN
SIGN TYPE 5
PARKING RESTRICTIVE SIGN - POLE MOUNTED
ATTACHMENT DETAIL - PLAN SECTION
BY CITY PRIOR TO FABRICATION.
PHONE NUMBERS AND ADDRESS TO BE PROVIDED
SEAL SIGN WITH TRANSPARENT ANTI-GRAFFITI FILM.
TO MATCH SURROUNDING COLOR.
ALL FASTENERS SHALL BE PLATED AND PAINTED
PAINT BACK SIGN PANEL TEAL.
OF SIGNS AROUND EDGES.
CONTINUE PAINT COLOR USED ON FRONT SURFACE
5.
4.
3.
2.
1.
SIGN PANEL
OF POST &
7-1 5-1E
5-1S
ELEVATIONSCOPY LAYOUT 5-1E
5-1SCOPY LAYOUT
FRONT SIDE1 2
NOTES:
03-23-17 REVISED COPY LAYOUTS "A" & "C" DJM
1"
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.03/31/2011
UserName=> carlosa Date Plotted: 2:25:07 PM10/5/2011 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> s:\V8EngStds\3000\ES3310.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY -XXXXREVISIONXX-XX-XXX
A. CARLOS
3310
NTS
1 OF 1
ES3310SIGN TYPE 6
IDENTIFICATION SIGN
ACCESSIBLE PARKING
ACCESSIBILITY
BACKGROUND COLOR:
DISABLED ACCESS BLUE
COPY & SYMBOL
COLOR: WHITE REFLECTIVE
OR APPROVED EQUAL
SIGN NO. R99C
WESTERN HIGHWAY
BACKGROUND COLOR:
DISABLED ACCESS BLUE
COPY COLOR: WHITE
OR APPROVED EQUAL
SIGN NO. RFHVA
WESTERN HIGHWAY
OR APPROVED EQUAL
SIGN NO. R99B
WESTERN HIGHWAY
SIGN TYPE 6
ACCESSIBLE PARKING IDENTIFICATION SIGN
NOTES:
BELEVATIONS
COPY LAYOUTS
A
C/L OF POST &
SIGN PANEL
2" SQ. PAINTED
STEEL POST
COLOR: WHITE
SIGN PANELS
1"
6’-8"
(80")
6-1
6-2
1 FRONT 2 SIDEAS REQ’D.
CONCRETE FOOTING
ATTACHMENT DETAIL - PLAN SECTION
C
STEEL POST
SIGN PANEL
ATTACH SIGN TO POST WITH TAMPER PROOF BOLT
PER WESTERN HIGHWAY STANDARD
TYPICAL SIGN TYPES 6 & 7
ACCESSIBLE PARKING ONLY SIGNS
1" BELOW BOTTOM EDGE OF EXISTING
NOTE: THIS SIGN ATTACHES TO POST
1’-0"
2’-0"
8" 9"
6-1
6-2 6-3
CALIFORNIA ACCESSIBILITY REGULATIONS CONTAINED IN TITLE 24, CALIFORNIA CODE OF REGULATIONS.
MUST COMPLY WITH THE AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES AND
ACCESSIBILITY PARKING SIGNS WHICH ARE SIMILAR TO THOSE SHOWN IN OUR STANDARDS
PAINT BACK OF SIGN PANEL BLUE.
SIGN COPY AND FINISHES SHALL CONFORM TO CALIFORNIA ACCESSIBILITY STANDARDS.
3.
2.
1.
7-1
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.03/31/2011
UserName=> carlosa Date Plotted: 2:25:08 PM10/5/2011 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> s:\V8EngStds\3000\ES3311.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
SIGN TYPE 7
ACCESSIBLE PARKING INFORMATION SIGN
NOTES:
SIGN COPY AND FINISHES SHALL CONFORM TO CALIFORNIA ACCESSIBILITY STANDARDS.1.
PAINT BACK OF SIGN PANEL BLUE.2.
PHONE NUMBERS AND ADDRESS TO BE PROVIDED BY CITY PRIOR TO FABRICATION.3.
ACCESSIBILITY PARKING SIGNS WHICH ARE SIMILAR TO THOSE SHOWN IN OUR STANDARDS 4.
MUST COMPLY WITH THE AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES
AND CALIFORNIA ACCESSIBILITY REGULATIONS CONTAINED IN TITLE 24, CALIFORNIA CODE OF REGULATIONS.
COPY LAYOUT
A
3/4"1/2"
3/4"
EQ"
EQ
1’-5"
1’-10"
ATTACHMENT DETAIL - PLAN SECTION
C
ATTACH SIGN TO POST WITH TAMPER PROOF BOLT
PER WESTERN HIGHWAY STANDARD
STEEL POST
SIGN PANEL
BACKGROUND COLOR:
DISABLED ACCESS BLUE
COPY COLOR: WHITE
SIGN PANEL TO BE:
WESTERN HIGHWAY
SIGN NO. RFH1824P
OR APPROVED EQUAL
BELEVATIONS
FRONT1 SIDE2
SIGN PANEL
C/L COPY &
-XXXXREVISIONXX-XX-XXX
A. CARLOS
3311
NTS
1 OF 1
ES3311
SIGN TYPE 7
ACCESSIBLE PARKING INFORMATION SIGN
CONCRETE FOOTINGAS REQ’D.
SIGN PANEL
C/L OF POST &
5-1E
5-1S
7-1
SIGN PANEL
2" SQ. PAINTED
STEEL POST
COLOR: WHITE
1"
80"
24" MIN.
1"
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.03/31/2011
UserName=> carlosa Date Plotted: 2:25:09 PM10/5/2011 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> s:\V8EngStds\3000\ES3314.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
1
3 2
1’-3" 3"
2 1/4"
CAP HT
6"
CAP HT
6 5/8"
ARROW
2 5/8"
2
8 3/4"
CIRCLE
DIAM.
SIGN PANEL
MATERIAL: 1/8" THICK ALUMINUM
FINISH: PAINTED TWO-PART
POLYURETHANE SATIN
COLORS TO MATCH:
PMS COOL GRAY 7C - BACK PANEL
PMS 323C TEAL - FACE CIRCLE
PMS 021C ORANGE - FACE TRACK 1
PMS 355C GREEN - FACE TRACK 2
PMS 542C SKY BLUE - FACE TRACK 3
COPY
MATERIAL: LASER CUT VINYL
FINISH: MATTE - NON GLARE
COLOR: BRIGHT WHITE
APPLICATION: FIRST SURFACE
1 1/2"
6
SIGN PANEL
6’-8"
(80")
R = 1/2"
(TYP.)
TRACK DIRECTIONAL / BACK PANEL
B
TRACK DIRECTIONAL / FACE PANEL COPY LAYOUTS
A
POST MOUNT WALL MOUNT / HIGH FENCE MOUNT
TYPICAL UNLESS NOTED OTHERWISE
HALF-HEIGHT FENCE MOUNT
C/L OF
C/L OF
SIGN PANEL
RECTANGLE
AND POST
5’-0"
(60")
MOUNT TOP EDGE
OF SIGN 1" BELOW
CROSS BAR ON
HALF-HEIGHT FENCES
(APPROXIMATELY
3’-0" FROM GRADE)
21 3
ELEVATIONS
D
SIGN POST: HARDSCAPE MOUNTING CONDITION WITH FLANGE
1
SIGN PANEL FACE
MATERIAL: 1/8" THICK ALUMINUM PANEL
CONSTRUCTION: ATTACH TO BACK PANEL WITH 3M VHB TAPE
AROUND PERIMETER & SILICONE ADHESIVE AS REQUIRED -
APPLY QUALITY PRIMARY TO ALL PAINTED
SURFACES TO PREVENT ELECTROLYSIS.
TYPICAL, ALL SIGNS..
SIGN PANEL BACK
MATERIAL: 1/8" THICK ALUMINUM PANEL
CONSTRUCTION: MECHANICALLY ATTACH TO POST WITH
FLUSH-HEAD SCREWS AS REQUIRED
3
CONCRETE
FOOTING TO DEPTH
AS REQUIRED
SIGN POST: LANDSCAPE MOUNTING CONDITION
POST
CONSTRUCTION: 2" SQUARE PAINTED STEEL
FINISH: PAINT TWO-PART POLYURETHANE SATIN
COLOR: WHITE
FLANGE
CONSTRUCTION: WELDED TO POST
AND FASTENED TO CONCRETE ANCHORS
WITH TAMPER-PROOF BOLTS
FINISH: PAINT COLOR: WHITE
EXISTING HARDSCAPE
EXISTING HARDSCAPE
SIGN POST: HARDSCAPE
MOUNTING CONDITION WITH CORE AND DRILL
2
CONCRETE POURED
INTO CORED HOLE
FLUSH-HEAD CONCRETE ANCHOR
DEPTH AS REQUIRED
SIGN PANEL BACK
1/8" PAINTED ALUMINUM
EXISTING MASONRY WALL
WALL MOUNT TO MASONRY5
TAMPERPROOF FASTENER
AND FLUSH HEAD SCREW
AS REQUIRED
SIGN PANEL BACK
1/8" PAINTED ALUMINUM
FENCE / GATE STRUT
FENCE MOUNT
1’-6"
BACK PANEL
SAME SIZE AS
SIGN PANEL
ATTACHMENT DETAILS
C
WITH VHB TAPE
ATTACH TO BACK PLATE
SIGN PANEL FACE
WITH VHB TAPE
ATTACH TO BACK PLATE
SIGN PANEL FACE
POST
SQUARE POST MOUNT4
FINISH: PAINT COLOR WHITE
-XXXXREVISIONXX-XX-XXX
A. CARLOS
3314
NTS
1 OF 1
ES3314
SIGN TYPE 11
TRACK DIRECTIONAL SIGN
21 3
SIGN POST: HARDSCAPE
MOUNTING CONDITION WITH CORE AND DRILL
2
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.03/31/2011
UserName=> carlosa Date Plotted: 2:25:10 PM10/5/2011 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> s:\V8EngStds\3000\ES3315.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
1
3 2
1’-3" 3"
1’-6"
6 5/8"
ARROW
2 1/2"
2 1/2"
8 3/4"
CIRCLE
DIAM.
SIGN PANEL
MATERIAL: 1/8" THICK ALUMINUM
FINISH: PAINTED TWO-PART
POLYURETHANE SATIN
COLORS TO MATCH:
PMS COOL GRAY 7C - BACK PANEL
PMS 323C TEAL - FACE CIRCLE
PMS 021C ORANGE - FACE TRACK 1
PMS 355C GREEN - FACE TRACK 2
PMS 542C SKY BLUE - FACE TRACK 3
COPY
MATERIAL: LASER CUT VINYL
FINISH: MATTE - NON GLARE
COLOR: BRIGHT WHITE
APPLICATION: FIRST SURFACE
1 1/2"
R = 1/2"
(TYP.)
ELEVATOR DIRECTIONAL / BACK PANEL
B
ELEVATOR DIRECTIONAL / FACE PANEL COPY LAYOUTS
A
POST MOUNT WALL MOUNT / HIGH FENCE MOUNT
TYPICAL UNLESS NOTED OTHERWISE
HALF-HEIGHT FENCE MOUNT
C/L OF
SIGN PANEL
C/L OF
SIGN PANEL
RECTANGLE
AND POST
5’-0"
(60")
MOUNT TOP EDGE
OF SIGN 1" BELOW
CROSS BAR ON
HALF-HEIGHT FENCES
(APPROXIMATELY
3’-0" FROM GRADE)
ELEVATIONS
D
POST
SIGN POST: HARDSCAPE
MOUNTING CONDITION WITH FLANGE
1
SIGN PANEL FACE
MATERIAL: 1/8" THICK ALUMINUM PANEL
CONSTRUCTION: ATTACH TO BACK PANEL WITH 3M VHB TAPE
AROUND PERIMETER & SILICONE ADHESIVE AS REQUIRED -
APPLY QUALITY PRIMARY TO ALL PAINTED
SURFACES TO PREVENT ELECTROLYSIS.
TYPICAL, ALL SIGNS.
SIGN PANEL BACK
MATERIAL: 1/8" THICK ALUMINUM PANEL
CONSTRUCTION: MECHANICALLY ATTACH TO POST WITH
FLUSH-HEAD SCREWS AS REQUIRED
SQUARE POST MOUNT4
3
CONCRETE
FOOTING TO DEPTH
AS REQUIRED
SIGN POST: LANDSCAPE MOUNTING CONDITION
POST
FINISH: PAINT TWO-PART POLYURETHANE SATIN
COLOR: WHITE
FLANGE
CONSTRUCTION: WELDED TO POST
AND FASTENED TO CONCRETE ANCHORS
WITH TAMPER-PROOF BOLTS
FINISH: PAINT COLOR: WHITE
EXISTING HARDSCAPE EXISTING HARDSCAPE
CONCRETE POURED
INTO CORED HOLE
FLUSH-HEAD CONCRETE ANCHOR
DEPTH AS REQUIRED
SIGN PANEL BACK
1/8" PAINTED ALUMINUM
EXISTING MASONRY WALL
WALL MOUNT TO MASONRY5
TAMPERPROOF FASTENER
AND FLUSH HEAD SCREW
AS REQUIRED
SIGN PANEL BACK
1/8" PAINTED ALUMINUM
FENCE / GATE STRUT
FENCE MOUNT6
BACK PANEL
SAME SIZE AS
SIGN PANEL
ATTACHMENT DETAILS
C
4’-11"
3"
WITH VHB TAPE
ATTACH TO BACK PLATE
SIGN PANEL FACE
WITH VHB TAPE
ATTACH TO BACK PLATE
SIGN PANEL FACE
CONSTRUCTION: 2" SQUARE PAINTED STEEL POST
FINISH PAINT COLOR: WHITE
-XXXXREVISIONXX-XX-XXX
A. CARLOS
3315
NTS
1 OF 1
ES3315
SIGN TYPE 12
ELEVATOR DIRECTIONAL SIGN
6"
6"
1’-3"
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.03/31/2011
UserName=> carlosa Date Plotted: 2:25:11 PM10/5/2011 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> s:\V8EngStds\3000\ES3316.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
ATTACHMENT DETAIL
FLAG MOUNT TO MASONRY WALLB
METAL BRACKET:
ATTACH TO EXISTING MASONRY WALL WITH
CONCRETE ANCHORS - DEPTH AND
SILICONE ADHESIVE AS REQUIRED
COLOR: GRAY
DOUBLE FACED SIGN PANEL
EXISTING MASONRY WALL
METAL BRACKET:
ATTACH TO SIGN PANEL WITH
FLUSH HEAD FASTENER
COLOR: GRAY
6’-8"
(80")
1/2"
1’-5" BRACKET
ELEVATION
FLAG MOUNT / TYPICAL UNLESS NOTED OTHERWISEC
COPY LAYOUTS
A
SIGN PANEL FACE 11
SIGN PANEL FACE 2 2
1’-6"
2"
4 5/8"
ARROW
HT
9 1/8"
SQ.
PICTO
SIGN PANEL
MATERIAL: 1/8" THICK ALUMINUM
FINISH: PAINTED TWO-PART
POLYURETHANE SATIN
COLOR: PMS 323C TEAL
COPY
MATERIAL: LASER CUT VINYL
FINISH: MATTE - NON GLARE
COLOR: BRIGHT WHITE
APPLICATION: FIRST SURFACE
2 5/8"
1 1/2"
MOUNTING
BRACKET
MOUNTING
BRACKET
3 1/4"
R = 1/2"
(TYP.)
SIGN TYPE 13
ELEVATOR IDENTIFICATION SIGN - FLAG MOUNTED
-XXXXREVISIONXX-XX-XXX
A. CARLOS
3316
NTS
1 OF 1
ES3316SIGN TYPE 13
FLAG MOUNTED
ELEVATOR IDENTIFICATION
" CLEAR213
5’-6"
8"
2’-
6"
7"
2"
"8
15
2’-9"
C
"16
13
11
"16
11
1’-
3
"8
53
"16
13
5"
2"
"21
"8
51
C
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 1:48:59 PM11/27/2012 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> S:\V8EngStds\Revisions in progress\es3317_revA.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
555, 369(i).§Trespassers subject to arrest. CA Penal Code
CAUTION!
NOT ALL TRAINS STOP AT STATION!
STAY BEHIND YELLOW LINE
(TYP)
OPP)
(TYP,
3" UPPER CASE LETTERS
UPPER CASE LETTERS
3�" HIGH RED
1" DIA HOLES
�"
2�" UPPER CASE LETTERS
1�" X 8" WHITE BAR AT CENTER9" DIA. RED STOP SYMBOL WITH
�" THICK BLACK BORDER
1�" RADIUS
1�" UPPER & LOWER CASE LETTERS
B 1 OF 1
3317
ACA
A. CARLOS
NTS
SYMBOLS
COLOR: YELLOW
" THICK PAINTED ALUMINUM81PANEL
COLOR: BLACKCOPY
COLOR: RED, WHITE, BLACKPICTOGRAPH
ANTI-GRAFFITTI FILMSEAL SIGN WITH TRANSPARENT
A
4’-0"
1’-2" DIA 3"3"
4’-0" 2’-10"
"2
11
3"
3"
3"
"4
32
DETAIL / PICTOGRAPHB
ES3317
C
1" X 2" SLOTTED HOLES
DETAIL "C" NOTES:
8.
7.
6.
5.
4.
3.
2.
1.
NOTE:
ES3307-03.METROLINK ENGINEERING STANDARDFOR MOUNTING INSTRUCTIONS SEE
04/11/11 ADDED DETAIL "C" AND NOTES NDP
ELEVATION - CROSSING WARNING SIGN
(SIGN TYPE 14)
CAUTION SIGN
AT STATION PLATFORMS
PEDESTRIAN WARNING SIGNS
03/31/2011
PEDESTRIANS.ON STATION PLATFORM AT LOCATIONS CLEARLY VISIBLE TO ALL PASSENGERS ANDFOR STATIONS THAT DO NOT HAVE INTERTRACK FENCING, SIGNS ARE TO BE LOCATED
COVER ENTIRE LENGTH OF PLATFORM.ADDITIONAL SIGNS TO BE SPACED 100 FEET APART AS NEEDED ALONG FENCING TOSIGNS TO BE PLACED STARTING 50 FEET AWAY FROM NEAREST PEDESTRIAN CROSSING,
FOR MOUNTING INSTRUCTIONS SEE METROLINK ENGINEERING STANDARD ES3307-03.
COLOR SPECIFICATIONS PER METROLINK ENGINEERING STANDARD ES3301.
COPY AND BORDER TO BE BLACK UNLESS OTHERWISE NOTED.
SIGN TO BE COATED WITH 3M 1160 PREMIUM PROTECTIVE OVERLAY.
SIGN FILM/SHEETING TO BE 3M HIGH INTENSITY PRISMATIC SERIES 3930-WHITE.
ALCOA 6016-T6 OR EQUAL.SIGN TO BE CONSTRUCTED OF �" THICK MILL FINISH ALUMINUM PANEL,
ACB 08-30-12 NDPREVISED NOTE 2
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.03/31/2011
UserName=> carlosa Date Plotted: 2:25:13 PM10/5/2011 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> s:\V8EngStds\3000\ES3318.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
SIGN MOUNTING INFORMATIONSEE ES4002 FOR ADDITIONAL
" DIA.414
COLOR: REDSYMBOL
COLOR: BLACKCOPY
PAINTED ALUMINUM
" THICK81PANEL
FILMANTI-GRAFFITTITRANSPARENTSEAL SIGN WITH
PER ES3307-02SEE DETAIL B-3FOR GATE CONDITIONMOUNTING DETAIL
12"
1"
14"
1"
"211
"851
"411
"431
"87
RESTRICTIVE SIGN COPY LAYOUT COPY LAYOUT
DETAIL
ELEVATION
4’-0"
B
C
A
NOTE:
-XXXXREVISIONXX-XX-XXX
A. CARLOS
3318
NTS
1 OF 1
ES3318SIGN TYPE 15
GATE MOUNTED
PEDESTRIAN DIRECTIONAL SIGN
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 3:34:54 PM11/15/2016 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\3000\ES3319_revA.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
SIGN TYPE 16
PEDESTRIAN DIRECTIONAL SIGN - POLE MOUNTED
AELEVATION
5'-0"
TO CENTER
OF ST 16
CONCRETE FOOTING AS REQUIRED
3'-0" FROM GATE
ST 16
SIGNS MOUNT TO 2" SQUARE
PAINTED ALUMINUM POST
COLOR: WHITE
COPY LAYOUT
B
SILKSCREENED COPY
COLOR: BLACK
3M EXTERIOR GRADE
VINYL DIE CUT SHEETING
COLOR: WHITE
SEAL SIGN WITH TRANSPARENT
ANTI-GRAFFITTI FILM
C/L OF PANEL & COPY
(SEE ATTACHMENT DETAIL 4 ES3307-03)
AACA
A. CARLOS 04/01/09
3319
NTS
1 OF 1
ES3319SIGN TYPE 16
POST MOUNTED
PEDESTRIAN DIRECTIONAL LOOK SIGN
3'-0" x 1'-6"
1'-6"
3'-0"
11-15-16 REVISED DETAIL B NDP
C
"2
11'-
0
3'-6"
1"
3"
2" 3"
1"
"2
11'-
0
STANDARDLIGHT
STEEL STRAPSTAINLESS
SIGN CABINET PAINTED WHITEAS REQUIREDALUMINUM CHANNEL
QUANTITY AS REQUIREDATTACHMENT SCREWS
(TYPICAL ALL SIGNS)ELECTROLYSIS.PAINTED SURFACES TO PREVENTAPPLY QUALITY PRIMER TO ALLFASTENERS AS REQUIRED:PANEL WITH TAMPERPROOFATTACH SIGN PANEL TO BACK
BENDING AND CURVING OF PANELFILLER TO PREVENT OIL-CANNING,STIFFENERS WITH STYROFOAMPROVIDE INERNAL METAL
SIGN CABINETTWO-PART PORCELAIN ENAMEL
LIGHT STANDARD
COLOR: TEALALUMINUM MOUNTING CHANNELBACK PANEL ATTACHED TO„" THICK PAINTED ALUMINUM
SIGN CABINET
TOP, BOTTOM & SIDESSTRIPE COLORS AROUNDCONTINUE BACKGROUND &
LIGHT STANDARD
COPY COLOR: WHITE
PANEL COLOR: TEAL
ES3301-02LOGO COLOR PER
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:47:34 AM4/25/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3320_revA.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
ELEVATIONSIDE ELEVATION
AB
C
—
D
E
ATTACHMENT DETAIL - SECTION
C
AACA
04/01/09A. CARLOS
3320
NTS
1 OF 1
ES3320
SIGN TYPE 20
STATION IDENTIFICATION SIGN (SMALL)
COPY LAYOUT
CONTINUE PAINT COLORS USED ON FRONT SURFACE 1.
OF SIGN CABINET AROUND EDGES.
BACK OF SIGN CABINET COLOR: TEAL. 2.
SIGN TYPE 20
STATION IDENTIFICATION SIGN
SMALL POLE MOUNTED
ATTACHMENT DETAIL - PLAN SECTION
NOTES:
OF LIGHT STANDARD & SIGN CABINET
03-23-17 REVISED COPY LAYOUT "A" AND ELEVATION "D" DJM
E
C
1'-
4"
3'-6"
1"
3"
2" 3"
1"
STANDARDLIGHT
STEEL STRAPSTAINLESS
SIGN CABINET PAINTED WHITEAS REQUIREDALUMINUM CHANNEL
QUANTITY AS REQUIREDATTACHMENT SCREWS
(TYPICAL ALL SIGNS)ELECTROLYSIS.PAINTED SURFACES TO PREVENTAPPLY QUALITY PRIMER TO ALLFASTENERS AS REQUIRED:PANEL WITH TAMPERPROOFATTACH SIGN PANEL TO BACK
BENDING AND CURVING OF PANELFILLER TO PREVENT OIL-CANNING,STIFFENERS WITH STYROFOAMPROVIDE INERNAL METAL
SIGN CABINETTWO-PART PORCELAIN ENAMEL
LIGHT STANDARD
COLOR: TEALALUMINUM MOUNTING CHANNELBACK PANEL ATTACHED TO„" THICK PAINTED ALUMINUM
SIGN CABINET
TOP, BOTTOM & SIDESSTRIPE COLORS AROUNDCONTINUE BACKGROUND &
LIGHT STANDARD
COPY COLOR: WHITE PANEL COLOR: TEAL
ES3301-02LOGO COLOR PER
1'-
4"
"8
11
1'-
4"
8'-
0"
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:47:35 AM4/25/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3321_revA.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
AACA
A. CARLOS 04/01/09
3321
NTS
1 OF 1
ES3321
SIGN TYPE 21
STATION IDENTIFICATION SIGN (LARGE)
AB
C
—
D
E
C
COPY LAYOUT
CONTINUE PAINT COLORS USED ON FRONT SURFACE 1.
OF SIGN CABINET AROUND EDGES.
BACK OF SIGN CABINET COLOR: TEAL. 2.
SIGN TYPE 20
STATION IDENTIFICATION SIGN
SMALL POLE MOUNTED
ATTACHMENT DETAIL - PLAN SECTION
NOTES:
OF LIGHT STANDARD & SIGN CABINET
E
ATTACHMENT DETAIL - SECTION SIDE ELEVATION ELEVATION
AF
G (T
YP)
03-24-17 REVISED COPY LAYOUT "D" AND ELEVATION "A" DJM
C
C
C
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 3:19:41 PM11/15/2016 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\3000\ES3322_revA.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
OF PANEL & POST
WALKWAY
80" MIN. IF IN
OF SIG
N P
AN
EL
AS REQUIRED
CONCRETE FOOTING
5'-0"
1"
SYMBOL & COPY
OF SIGN PANEL,
COLOR: BLACK
SILKSCREENED COPY
COLOR: WHITE
DIE CUT SHEETING
REFLECTIVE VINYL
3M EXTERIOR GRADE
COLOR: BLACK
SILKSCREENED COPY
2'-6"
3"
2"
ELEVATIONS COPY LAYOUTB A
22-1
DETAILS
FOR ATTACHMENT
SEE B5 ES3307-02
COLOR: WHITE
STEEL POST
2" SQ. PAINTED
AACA
A. CARLOS 04/01/09
3322
NTS
1 OF 1
ES3322SIGN TYPE 22
POST MOUNTED
CPUC RAILROAD CROSSING SIGN
R R
CROSSING
RAILROAD
ONLYAND BICYCLESPEDESTRIANS
2"
1"
1"
"41
1
2"
2"
2"
"2
11'-2
"43
5
"43
"21
1
10-07-16 REVISE CROSSING SIGN NDP
" (TYP)21
R = 1
"21
1
"21
1
GALVANIZED BOLTS
" DIA165
" DIA HOLES FOR 83
1'-6"
C
C
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.03/31/2011
UserName=> carlosa Date Plotted: 2:25:17 PM10/5/2011 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> s:\V8EngStds\3000\ES3323.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
SIGN TYPE 23
ACCESSIBILITY SIGN
ACOPY LAYOUTS
CPLAN
R = 1/2" (TYP.)
SILKSCREENED SYMBOL
COLOR: WHITE
BACKGROUND COLOR:
DISABLED ACCESS BLUE
23-1
EQ.
EQ.
8"1’-0"
1’-0"
6"
1"
1"
4"
B
2" SQ. PAINTED STEEL POST. COLOR: WHITE
SIGN TYPE 25
STATION IDENTIFICATION
SIGN TYPE 23-1
HANDRAIL
WELDED STEEL FLANGE
W/ TAMPER PROOF
CONCRETE ANCHOR BOLTSELEVATION
ACCESS RAMP FRONT
6’-8"
MINIMUM
DISTANCE
AS REQ’D
DDETAIL - PLAN
ACCESS
RAMP
FLANGE
ALIGN WITH
BOTTOM OF RAMP
HANDRAIL
SIGN POST
SIGN TYPE
D-25
STATION ID & ACCESSIBILITY
SIGNS TO BE MOUNTED
PERPENDICULAR TO TRACK
EDGE OF PLATFORM
ACCESS
RAMP
SIGN POST
TRACK
23-1a
(SEE ATTACHMENT DETAIL 4 ES3307-03)
(SEE D5 ES3325)
& SYMBOL
OF SIGN PANEL
-XXXXREVISIONXX-XX-XXX
A. CARLOS
3323
NTS
1 OF 1
ES3323
SIGN TYPE 23
ACCESSIBILITY SIGN
POST & SIGN PANEL
EQ. EQ.
1'-0"
1'-
0"
1"
†"
1"
1"
WALL
SIGN PANEL
C
60"
C
SIGN PANEL
6'-
8"
C
SIGN PANEL
6'-
8"
CONOPY
SIGN PANEL
SIGN PANEL
FENCE
COLOR: WHITE (TYP)COPY SILKSCREENED
ALUMINUM PANEL (TYP)„" THICK PAINTED
(TYP)R = •"
ACCESS BLUEDISABLEDAND BACK:COLOR FRONTBACKGROUND
BLACKCOPY COLOR:STRIPES &
YELLOW& BACK:COLOR FRONTBACKGROUND
1"
1"
COLOR: ORANGE
BACKGROUND COLOR: TEAL (TYP)
1"
2ƒ
"ES3301-02 (TYP)LOGO COLORS PER
COLOR: WHITE
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:47:35 AM4/25/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3324_revA.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
AACA
A. CARLOS 04/01/09
3324
NTS
1 OF 1
ES3324
SIGN TYPE 24
PEDESTRIAN RESTRICTIVE / INFORMATION SIGN
A
B
COPY LAYOUTS
1 3 4 52
PANELOF SIGN
SIGN PANELOF POST &
(8
0")
WALL MOUNT
(SEE 5 ES3307-03 FOR INSTALLATION)
POST MOUNT
(SEE 4 ES3307-03 FOR INSTALLATION)
LIGHT POLE MOUNT
(SEE 6 ES3307-03 FOR INSTALLATION)
CANOPY MOUNT
(SEE 4 ES3307-03 FOR INSTALLATION)
FENCE MOUNT
(SEE 7 ES3307-03 FOR INSTALLATION)
ELEVATIONS
POLE & SIGN PANELOF LIGHT STANDARD
(8
0")
1"
1"
1"
1"
1 ‚"
•"
•"
1" ALIGN 1 •" ALIGN
1 ‚"
3"
1"
1"
3 •"
ƒ"
1" ALIGN
2 ƒ"
ƒ"…"
ƒ"
ƒ"
1" ALIGN
1"
†"
†"
1" ALIGN
1"
1 ‚"
1 ƒ"
ƒ"
5/8"STRIPE
5/8" SPACE1" ALIGN
45°
1"
1"
1 †"
1 ‚" ƒ"
•"
1 ƒ" ƒ"
•"
ƒ"
•"
ƒ"
24-1 24-6 24-224-324-4
24-524-8
VERIFY SPANISH TRANSLATIONS WITH METROLINK PRIOR TO FABRICATION.5.SEAL SIGNS WITH TRANSPARENT ANTI-GRAFFITI FILM.4.BACK OF SIGN PANELS TO BE PAINTED TEAL UNLESS NOTED.3.CONTINUE PAINT COLOR USED ON FRONT SURFACE OF SIGNS AROUND EDGES.2.ALL DIMENSIONS & NOTES TYPICAL EXCEPT AS NOTED.1.
NOTES:
(T
YP)
(TYP)
03-24-17 REVISED SIGN LAYOUTS DJM
1"
1"
1"
3"
1"
AKZIDENZ GROTESK SUPERENGLISH COPY: BERTOLD
AKZIDENZ GROTESK MEDIUMSPANISH COPY: BERTOLD
2"
3"
C
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.03/31/2011
UserName=> carlosa Date Plotted: 2:25:19 PM10/5/2011 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> s:\V8EngStds\3000\ES3325.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
SIGN TYPE 25
A.D.A. STATION IDENTIFICATION SIGN
ACOPY LAYOUT
R = 1/2" (TYP.)23-1
1"
1 1/4"
1 7/8"
3/8" MIN.
1’-0"
1"
PAINTED BACKGROUND /
FRONT, SIDE EDGES, BACK
COLOR: TEAL
1’-0"
1/8" THICK ACID ETCHED ZINC
PLAQUE W/ ROLLER-COATED
COLOR & CLEAR MATTE
PROTECTIVE COATING
1/32" RAISED TACTILE COPY
COLOR: WHITE
CALIFORNIA CONTRACTED
BRAILLE
B
2" SQ. PAINTED
STEEL POST
COLOR: WHITE
(SEE ATTACHMENT
SIGN TYPE 23-1
WELDED STEEL FLANGE
W/ TAMPER PROOF
CONCRETE ANCHOR BOLTS
ELEVATION
5’ (60")
TO TOP LINE
OF COPY
CDETAIL - PLAN
SCALE: NTS
FLANGE
SIGN POST
SIGN TYPE 23
SIGN TYPE 25
CONCRETE FOOTING
AS REQ’D.
SIDE1 FRONT2
1" DETAIL 4 ES3307-03)
-XXXXREVISIONXX-XX-XXX
A. CARLOS
3325
NTS
1 OF 1
ES3325
SIGN TYPE 25
ADA STATION IDENTIFICATION SIGN (BRAILLE)
POST & SIGN PANEL
2'-6"
7'-
9"
3'
3'-
6"
1'-
3"
3"
3"
6"
4"
3"
2'-
6"
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:47:36 AM4/25/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3326_revA.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
AACA
A. CARLOS 04/01/09
3326
NTS
1 OF 1
ES3326SIGN TYPE 26
FREESTANDING
MAP / INFO KIOSK
3" 3"
1 1/2"1 1/2"
1 •
"1 •
"
LOGO TO BE ETCHED INTO ALL FOUR
SIDES; DO NOT FILL WITH PAINT
ST. STL. DOOR TO BE FLUSH
W/ SURFACE OF FRAME
CYROLON AR POLYCARBONATE
PANEL W/ ABRASION RESISTANT COATING
ON EXTERIOR SURFACE
BACK PANEL TO BE PAINTED STL. SUFFICIENT
TO ACCEPT MAGNETS OR TAPED MAPS
COLOR: WHITE
PERMANENTLY
ANCHOR BASE TO EXISTING
HARDSCAPE AS REQ'D
NOTE: ALL SIDES IDENTICAL.
TAMPERPROOF BOLT,
TOP & BOTTOM OF
CONCEALED HINGE ALONG RIGHT
EDGE OF DOORS
INTERNAL STORAGE SHELF
DOOR
1 ƒ" LOGO
LO
GO
1"
STEEL GRAINDIRECTION OF STAINLESS
RIDGE OF CABINET
INTERIOR
STORAGE
SHELF
& LOGOC/L OF CABINET RIDGE
MAP/ INFO KIOSK - FREESTANDING
SIGN TYPE 26
24" X 36"OPENING SIZE
PANELS.
PROVIDE CHANNELS AS REQ'D TO FACILITATE REPLACEMENT OF CLEAR WINDOW
SHOW ALL DETAILS ON SHOP DRAWINGS.
ACCESS TO CABINET SHALL BE BY REMOVING BOLTS ALONG LEFT SIDE OF DOORS.
PROVIDE NON-HINGED SIDE OF PANEL W/ STAR-HEAD BOLTS.
CABINET SHALL HAVE ONE HINGED INTERIOR PANEL TO ACCESS STORAGE SHELF.
CABINET SHALL HAVE INTERIOR STORAGE SHELF.
SIDE OF DOOR TO PREVENT BOLTS FROM BEING REMOVED.
STAR-HEAD BOLTS ON NON-HINGED SIDE. WELD NUT TO BOLT ON INTERIOR
CABINET DOORS SHALL HAVE STAINLESS STEEL COUNTERSUNK, TAMPERPROOF
CABINET SHALL BE WEATHERPROOFED.
ALL LOCAL CODES & WIND LOAD FACTORS.
SHALL ENGINEER FABRICATION & INSTALLATION OF CABINET TO SATISFY
(CONDITIONS VARY) FOR SAFE AND SECURE INSTALLATION. SIGN CONTRACTOR
CABINET SHALL BE WEIGHTED AND ANCHORED TO EXISTING HARDSCAPE
CABINET SHALL HAVE NO VISIBLE SEAMS.
TO PREVENT SEPARATION.
STEEL STRUCTURE AS REQUIRED. ALL CORNERS SHALL BE REINFORCED
GRAIN BRUSHED FINISH. CABINET SHALL BE CONSTRUCTED WITH INTERNAL
KIOSK CABINET SHALL BE FABRICATED STAINLESS STEEL W/ VERTICAL
10.9.8.
7.6.
5.4.
3.2.
1.
A B CELEVATION PLAN ISOMETRIC26-1
‚" REVEAL
WINDOW TO BE ‚" (MIN.)
‚" REVEAL
03-24-17 REVISED LOGO DJM
NOTES:
ES3301-02LOGO COLOR PER
PANEL COLOR: TEAL
COPY COLOR: WHITE
VA
RIE
S12 •
"
3'-6"
C
(WHERE OCCURS)SIGN TYPE 24
COLOR: WHITE3" SQ. PAINTED STEEL POST
LANDSCAPE CONDITION
1"
ENAMEL SIGN CABINETTWO-PART PORCELAIN
(WHERE OCCURS)SIGN TYPE 24
AS REQUIREDCONCRETE FOOTING
5'-
0"
SIGN PANEL
(WHERE OCCURS)SIGN TYPE 24
POST
PLATFORM
PAINTED STEEL POST
AS REQUIREDPROVIDE ATTACHMENT HARDWARE
PORCELAIN CABINETSIGN TYPE
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:47:37 AM4/25/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3327_revA.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
D
ABC
AACA
A. CARLOS 04/01/09
3327
NTS
1 OF 1
ES3327SIGN TYPE 27
AT TRACK
ADA STATION IDENTIFICATION
OF LIGHT STANDARD & SIGN CABINET
(A
LIG
N
WIT
H
SIG
N
TY
PE 21)
TO
P
OF
PL
AT
FO
RM
TO
BE 8'-
0"
CL
EA
R
FR
OM
BO
TT
OM
OF
SIG
N
PA
NE
L
SIGN TYPE 27
ADA STATION IDENTIFICATION SIGN - AT TRACK
CONTINUE PAINT COLOR USED ON FRONT SURFACE OF SIGNS AROUND EDGES.1.
PAINT BACK SIGN PANEL TEAL.2.
ALL FASTENERS SHALL BE STAINLESS STEEL & SHALL BE PAINTED TO MATCH SURROUNDING COLOR.3.
SEAL SIGN WITH TRANSPARENT ANTI-GRAFFITI FILM.4.
REFER TO ES3320 AND ES3321 FOR ADDITIONAL FABRICATION NOTES.5.
NOTES:
24-01
PLAN SECTION
INSTALLATION DETAIL SIDE ELEVATION 27-1
03-24-17 REVISED ELEVATION "A" DJM
VE
RIF
Y
VERIFY
6'-
8"
6'-
8"
6'-
8"
6" WHERE OCCURS
EQ. EQ.
C
"2
11
3"
3'-
6"
2'-6"
2'-6" 2'-6"
"2
12
"2
12
"2
12
WALL
DISPLAY CASE
AS REQUIREDCASE TO WALLANCHOR DISPLAY
•" REVEAL
DISPLAY CASES
EXISTING POST
(TYP)•" STANDOFF
(TYP)TO POST AS REQUIREDANCHOR DISPLAY CASE
ALIGN
FRONT OF CASE
FRONT OF CASE
4"
3"
3'
"2
11
DO NOT FILL WITH PAINTINTO FRONT OF PANEL:LOGO TO BE ETCHED
1.05 LOGO LETTER HEIGHT
‚" REVEAL
TOP PANELSTAINLESS STEEL
TOP & BOTTOM OF DOORTAMPER PROOF BOLTS
TAPED MAPS, COLOR: WHITESUFFICIENT TO ACCEPT MAGNETS ORBACK PANEL TO BE PAINTED STEEL
FLUSH WITH SURFACE OF FRAMESTAINLESS STEEL DOOR TO BE
ON EXTERIOR SURFACEPANEL WITH ABRASION RESISTANT COATING‚" (MIN.) CYROLON AR POLYCARBONATE
RIGHT EDGE OF DOORSCONCEALED HINGE ALONG
WALL
WALL ANCHOR (TYP)
TOP PANEL
REVEAL
DISPLAY CASE
3" SQUARE LOGO
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:47:37 AM4/25/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3328-01_revA.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
AACA
A. CARLOS 04/01/09
3328
NTS
1 OF 2
ES3328-01SIGN TYPE 28
WALL OR POST MOUNTED
DISPLAY CASE
SIGN TYPE 28
DISPLAY CASE
WALL MOUNTED
PLAN
POST/CANOPY MOUNTED21
NOTE:
REFER TO D-26 FOR FABRICATION & INSTALLATION NOTES.
1 FRONT
ELEVATION - CANOPY STRUCTURE MOUNTED
2 SIDE
ELEVATION - WALL MOUNTED ELEVATION 28-1 SIDE
BACK-TO-BACK
DISPLAY CASE
ON EXIST. POSTS
&
PA
NE
L
OF
LO
GO/
SY
MB
OL
1/2" SPACER
03-27-17 REVISED ELEVATION "B" DJM
24" X 36"
OPENING SIZE
D
E
C B A
EQ. EQ.
C"
21
1
3"
3'-
6"
2'-6"
4"
"2
11
DO NOT FILL WITH PAINTINTO FRONT OF PANEL:LOGO TO BE ETCHED
1.05 LOGO LETTER HEIGHT
‚" REVEAL
TOP PANELSTAINLESS STEEL
TOP & BOTTOM OF DOORTAMPER PROOF BOLTS
TAPED MAPS, COLOR: WHITESUFFICIENT TO ACCEPT MAGNETS ORBACK PANEL TO BE PAINTED STEEL
FLUSH WITH SURFACE OF FRAMESTAINLESS STEEL DOOR TO BE
ON EXTERIOR SURFACEPANEL WITH ABRASION RESISTANT COATING‚" (MIN.) CYROLON AR POLYCARBONATE
RIGHT EDGE OF DOORSCONCEALED HINGE ALONG
3" SQUARE LOGO
3"
3'-
0"
POST AS REQUIRED (TYP)ANCHOR DISPLAY CASE TODISPLAY CASE
PAINTED WHITE‚" SPACER
PAINTED COLOR: WHITENEW 3" SQUARE STEEL POST
6'-
8"
CASEDISPLAY
NEW POST
NEW POST
CASEFRONT OF
COLOR: WHITE (TYP)3" SQUARE STEEL POST
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:47:38 AM4/25/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3328-02_revA.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
AACA
A. CARLOS 04/01/09
3328
NTS
2 OF 2
ES3328-02SIGN TYPE 28
POST MOUNTED SINGLE SIDED
DISPLAY CASE
&
PA
NE
L
OF
LO
GO/
SY
MB
OL
AB
C
CONCRETE FOOTING OR FLANGE-MOUNT AS
REQUIRED. SIGN CONTRACTOR TO ENGINEER
DETAILS AND SHOW ON SHOP DRAWINGS.
SEE SHEETS ES3312 AND ES3322.
SIDE2FRONT1
SIGN TYPE 28
DISPLAY CASE - SINGLE SIDED
DISPLAY CASE SHALL BE FABRICATED STAINLESS STEEL W/ VERTICAL1.
CASE SHALL HAVE NO VISIBLE SEAMS.2.
CASE SHALL BE WEIGHTED AND ANCHORED TO EXISTING HARDSCAPE3.
CASE SHALL BE WEATHERPROOFED.4.
CASE DOORS SHALL HAVE STAINLESS STEEL COUNTERSUNK, TAMPERPROOF5.
SHOW ALL DETAILS ON SHOP DRAWINGS.6.
PROVIDE CHANNELS AS REQ'D TO FACILITATE REPLACEMENT OF 7.
CLEAR WINDOW PANELS.
GRAIN BRUSHED FINISH. CASE SHALL BE CONSTRUCTED WITH INTERNAL
STEEL STRUCTURE AS REQUIRED. ALL CORNERS SHALL BE REINFORCED
TO PREVENT SEPARATION.
(CONDITIONS VARY) FOR SAFE AND SECURE INSTALLATION. SIGN CONTRACTOR
SHALL ENGINEER FABRICATION & INSTALLATION OF CASE TO SATISFY
ALL LOCAL CODES & WIND LOAD FACTORS.
STAR-HEAD BOLTS ON NON-HINGED SIDE. WELD NUT TO BOLT ON INTERIOR
SIDE OF DOOR TO PREVENT BOLTS FROM BEING REMOVED.
NOTES:
PLAN
ELEVATIONELEVATION - POST MOUNTED
24" X 36"OPENING SIZE
03-27-17 REVISED ELEVATION "A" DJM
C
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 1:49:00 PM11/27/2012 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3330-01_revA.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
SIGN TYPE 30
POSITION MARKER & TRACK IDENTIFICATION SIGN
ATTACH SIGN PANEL TO CANOPY STRUCTURE
WITH TAMPER PROOF BOLTS AS REQ’D.
PAINT BOLTS TO MATCH SIGN PANEL COLOR
CATTACHMENT DETAIL
STEEL CANOPY STRUCTURE
3" SQ. PAINTED
STEEL POST
COLOR: WHITE
1/8" THICK PAINTED ALUM. SIGN
PANEL ATTACHED TO BACK PANEL
W/ 3M VHB TAPE AROUND PERIMETER
& SILICONE ADHESIVE AS REQ’D.
FOR SAFE & SECURE MOUNTING
PLAN SECTION
F
1/8" THICK PAINTED ALUM.
BACK PANEL MECHANICALLY
ATTACHED TO POST
W/ FLUSH-HEAD SCREWS
AS REQ’D. (COLOR TO MATCH
SIGN COLOR)
1’-0"
COPY LAYOUTS
1"
2"
1/8" THICK ALUMINUM PANEL
WITH VINYL COVERED SURFACE
BACKGROUND
COLOR: WHITE
REFLECTIVE
(TYP.)
PANEL EDGES
COLOR: WHITE
(TYP.)
VINYL COPY
COLOR: BLACK
(TYP.)
30-1
30-3
R = 1/2" (TYP.)
A
3 1/8"
2 1/2"
3 1/2"
1’-0"
SIGN TYPE 21
C/L OF POST & SIGN PANEL
30-1
TOP OF RAIL
12’-0"
ELEVATIONSE
4" CLR.
30-6
30-5
30-4
30-3
NOTE:
USE CORE & DRILL INSTALLATION METHOD OR FLANGE METHOD
WHEN SIGNS ARE INSTALLED ON PLATFORM.
USE CONCRETE FOOTING WHEN INSTALLING IN RIGHT OF WAY.
SIGN PANEL @ POST
(SEE ATTACHMENT
SIGN PANEL @ POST
(SEE ATTACHMENT
DPARTIAL ELEVATION - CANOPY
CANOPY
SIGN PANEL
MOUNTED FLAT
TO CANOPY ROOF
BELEVATION - CANOPY STRUCTURE MOUNTED
NEW POST
LIGHT STANDARD/
POLE
PLATFORM
POST
NEW
2"
5"
REFER TO ES3307-03 FOR DETAILS.
DETAILS 2, 3/ ES3307-03) DETAIL 3/ ES3307-03)
AACA
A. CARLOS 04/01/09
3330
NTS
1 OF 6
ES3330-01
SIGN TYPE 30
TRAIN POSITION MARKER
OF COPY & SIGN PANEL
11’-4"
04/18/12 REVISED ELEVATION "E" NDP
C/L OF POST & SIGN PANEL
11’-4"
VINYL COPY
COLOR: BLACK
(TYP.)VINYL COPY
COLOR: WHITE
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.03/31/2011
UserName=> carlosa Date Plotted: 2:25:24 PM10/5/2011 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> s:\V8EngStds\3000\ES3330-02.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
EXISTING SIGN
C
30-1
COPY LAYOUTS
B
OLD LOCOMOTIVE NEW LOCOMOTIVE30A-3 30B-3
2 1/2"
3 1/2"
1’-0"
1/8" THICK ALUMINUM PANEL
WITH VINYL COVERED SURFACE
BACKGROUND
COLOR: WHITE
REFLECTIVE
(TYP.)
PANEL EDGES
COLOR: WHITE
(TYP.)
R = 1/2" (TYP.)
1’-0"
2 1/4"
1’-0"
1’-0"
2"
1 1/4"
4 1/4"
3 1/8"
BACKGROUND
COLOR: BLUE
REFLECTIVE
SIGN TYPE 30.1
LOCOMOTIVE POSITION MARKER SIGN
ELEVATION / COMPARISON OF NEW AND EXISTING SIGNS
NEW LOCOMOTIVE OLD LOCOMOTIVE
A
12’-6"12’-0"
PAINTED STEEL POST
COLOR: WHITE
-XXXXREVISIONXX-XX-XXX
A. CARLOS
3330
NTS
2 OF 6
ES3330-02
SIGN TYPE 30
NEW TRAIN POSITION MARKER
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 1:49:00 PM11/27/2012 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3330-03_revA.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
PLAN
SCALE: NTS
TRACK
PLATFORM
30A-330-1
OLD LOCOMOTIVE
SIGN KEY
30B-3
NEW LOCOMOTIVE
SPOT CAB
30-1
30A-630B-6 30A-530B-5 30A-430B-4 30A-330B-3
241’-0"85’-0"85’-0"85’-0"
253’-6"85’-0"85’-0"85’-0"
IDENTIFICATION DECAL
APPLIED TO
TICKET VALIDATOR
31-1
NEW LOCOMOTIVE
OLD LOCOMOTIVE
NOT FOR CONSTRUCTION
NOTE:
THIS REPRESENTS A TYPICAL METROLINK STATION
AND IS SHOWN FOR REFERENCE ONLY.
ACTUAL STATIONS MAY VARY FROM THIS PLAN.
C/L ACCESSIBLE PLATFORM
AACA
A. CARLOS 04/01/09
3330
NTS
3 OF 6
ES3330-03
TYPICAL SIGN LOCATION PLAN
SIDE PLATFORM
04/19/12 REVISED SPOT CAB DIMENSIONS NDP
AND PLATFORM
ACCESSIBLE RAMP
50’-0"
50’-0"
30B
30A
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 1:49:08 PM11/27/2012 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3330-04_revA.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
PLAN
SCALE: NTS
TRACK 2
CAR-LOCATOR SIGNS WILL BE REQUIRED
DO NOT ALIGN, TWO SETS OF
NOTE: WHERE MINI-HIGH PLATFORMS
FENCE
TRACK 1
241’-0"85’-0"85’-0"85’-0"
253’-6"85’-0"85’-0"85’-0"
SPOT
CAB
SPOT
CAB
30A-630B-6 30A-530B-5 30A-430B-4 30A-330B-3
30-1
30-1
NEW LOCOMOTIVE
OLD LOCOMOTIVE
IDENTIFICATION DECAL
APPLIED TO
TICKET VALIDATOR
31-1
C/L OF TRACK 2 MINI-HIGH PLATFORM
C/L OF TRACK 1 MINI-HIGH PLATFORM
NOT FOR CONSTRUCTION
NOTE:
THIS REPRESENTS A TYPICAL METROLINK STATION
AND IS SHOWN FOR REFERENCE ONLY.
ACTUAL STATIONS MAY VARY FROM THIS PLAN.
30A-330-1
OLD LOCOMOTIVE
SIGN KEY
30B-3
NEW LOCOMOTIVE
AACA
A. CARLOS 04/01/09
3330
NTS
4 OF 6
ES3330-04
LOCOMOTIVE POSITION MARKER PLAN
SIDE PLATFORMS
50’-0"
50’-0"
50’-0"
50’-0"
04/19/12 REVISED SPOT CAB LOCATIONS NDP
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 1:49:09 PM11/27/2012 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3330-05_revA.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
PLAN
SCALE: NTS
30-1
30-1
241’-0"85’-0"85’-0"85’-0"
253’-6"85’-0"85’-0"85’-0"
253’-6" 85’-0"
241’-0" 85’-0"
85’-0"
85’-0"
85’-0"
85’-0"
30A-630B-6 30A-530B-5 30A-430B-4 30A-330B-3
30A-3 30B-3 30A-4 30B-4 30A-5 30B-5 30A-6 30B-6
TICKET VALIDATOR
APPLIED TO
IDENTIFICATION DECAL
31-1
NOT FOR CONSTRUCTION
NOTE:
THIS REPRESENTS A TYPICAL METROLINK STATION
AND IS SHOWN FOR REFERENCE ONLY.
ACTUAL STATIONS MAY VARY FROM THIS PLAN.
C/L OF MINI-HIGH PLATFORM
NEW LOCOMOTIVE
OLD LOCOMOTIVE
C/L OF MINI-HIGH PLATFORM
NEW LOCOMOTIVE
OLD LOCOMOTIVE
TRACK 2
FENCE
TRACK 1
30A-330-1
OLD LOCOMOTIVE
SIGN KEY
30B-3
NEW LOCOMOTIVE
AACA
A. CARLOS 04/01/09
3330
NTS
5 OF 6
ES3330-05
LOCOMOTIVE POSITION MARKER PLAN
SIDE PLATFORMS
50’-0"
50’-0"
50’-0"
50’-0"
04/19/12 REVISED SPOT CAB LOCATIONS NDP
DIRECTOR OF ENGINEERING AND CONSTRUCTION
ENGINEERING STANDARDS
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 1:49:09 PM11/27/2012 Plot Driver=> S:\Plot Drivers\pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3330-06_revA.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
IDENTIFICATION DECAL
APPLIED TO
TICKET VALIDATOR
31-1
241’-0"85’-0"85’-0"85’-0"
253’-6"85’-0"85’-0"85’-0"
30A-330B-330A-430B-530A-530B-530A-630B-6
NOT FOR CONSTRUCTION
NOTE:
THIS REPRESENTS A TYPICAL METROLINK STATION
AND IS SHOWN FOR REFERENCE ONLY.
ACTUAL STATIONS MAY VARY FROM THIS PLAN.
SPOT CAB
30-1
TRACK
TRACK
OLD LOCOMOTIVE
NEW LOCOMOTIVE
PLAN
SCALE: NTS
PLATFORM
C/L ACCESSIBLE PLATFORM
30A-330-1
OLD LOCOMOTIVE
SIGN KEY
30B-3
NEW LOCOMOTIVE
AACA
A. CARLOS 04/01/09
3330
NTS
6 OF 6
ES3330-06
LOCOMOTIVE POSITION MARKER PLAN
CENTER PLATFORM
50’-0"
50’-0"
04/19/12 REVISED SPOT CAB LOCATIONS NDP
8'-
0"
QUANTITY AS REQUIRED
ATTACHMENT SCREWS,ATTACH TWO SIGNS PER POST
SIGN PANEL
„" THICK ALUMINUM
CALL BOX
BY OTHERS
SOLAR PANEL & ANTENNA
C
3"
6"
7"
2"
3"
1•
"
2'-6"
3'-
0"
2"
2"
1"
R = •" (TYP)
ES3301-02
LOGO COLOR PER
SURROUNDING COLOR
AS REQUIRED PAINT TO MATCH
MOUNTING SCREWS OR LAG BOLTS
1'-
9"
2"2"
COLOR: ORANGECONTRAST STRIPE
PANEL COLOR: TEAL
FOREGROUND COLOR: WHITE
BACKGROUND COLOR: BLACK
REFLECTIVE VINYL DIE CUT GRAPHICS
MESSAGE COLOR: WHITE
REFLECTIVE VINYL DIE CUT
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:47:38 AM4/25/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3332_revA.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
AACA
A. CARLOS 04/01/09
3332
NTS
1 OF 1
ES3332
SIGN TYPE 41
PASSENGER INFORMATION TELEPHONE
SCALE: 1•" = 1'-0"
COPY LAYOUT ELEVATION
SCALE: NONE
PLAN SECTION - POLE MOUNTED
SCALE: NONE
NOTES:
SEAL SIGN WITH TRANSPARENT ANTI-GRAFFITI FILM
ALL FASTENERS SHALL BE PLATED AND PAINTED TO MATCH SURROUNDING COLOR.
PAINT BACK SIGN PANEL TEAL.
CONTINUE PAINT COLOR USED ON FRONT SURFACE OF SIGNS AROUND EDGES.
4.
3.
2.
1.
FRONT VIEW - LIGHT POLE MOUNTED
03-22-17 REVISED SIGN DETAILS DJM
POST MOUNTED
1"
COMM. VAULT
FOR CONDUIT SIZES
SEE ES3405-01
SEE 3402-01
FOR DETAIL
SEE NOTE 5
LOCATION
TVM PAD
(TYP)
CANOPY
PLATFORM
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 12:36:48 PM7/23/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3401-01_revB.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
TELCO
(4)
(6)
(4)
(4)
(4)
(4)
(1)
(4)
(4)
(4)
(2)
ACCESS POINT
COMMERCIAL POWER
GENERAL ARRANGEMENT OF SYSTEM AND WORK
DRAWING IS DIAGRAMMATIC AND INDICATES
(2)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(2)
(2)
(4)(2)
SHELTER
COMMUNICATION
FIBER VAULT
FIBER VAULT
PLATFORM
E
C
E E E E
E
E
C C C
E E E
C C C
V
V
V
E
C
E
C
E
C
E
C
E
C
E
C
E
C
E
C
E
C
E
C
1
C
E
NOTES:
04/01/03A. CARLOS
ACA 09/07/12 NDP
E
C 2 3
OMIT MTTV, TVM, DVM, REVISE NOTE 1 & TVM PAD
MESSAGE SIGN LOCATIONS.
REFER TO ES3503 FOR CAMERA, SPEAKER AND LED
TVM PAD LOCATION VARIES BY STATION.
FOR ADDITIONAL NOTES AND LEGEND SEE ES3001.
STANDARD DRAWINGS ES9400 THRU ES9440.
FOR COMMUNICATIONS SHELTER SEE COMMUNICATIONS
ARE ENERGIZED FROM THE COMMUNICATIONS SHELTER.
PUBLIC ADDRESS AND LED MESSAGE SIGNS (PA & LED)
STATION POWER SOURCE. (SEE ES3405-01 & ES3405-02).
ALL TICKET VENDING MACHINES ARE ENERGIZED FROM THE
6.
5.
4.
3.
2.
1.
ACB 07/10/15 NDPREVISED LIGHT POLE SYMBOLS, ADD NOTE 6
LVM
SIDE PLATFORMMETROLINK STATION CONDUIT LAYOUT
ES3401-01
1 OF 2
NTS
3401
B
FOR CONDUIT SIZES
SEE ES3405-01
SEE NOTE 5
LOCATION
TVM PAD
SEE 3402-02
FOR DETAIL
PLATFORM(TYP)
CANOPY
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 12:36:49 PM7/23/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3401-02_revB.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
C
(6)
(1)
(4)
E
(4)
(2)
V
V
(2)
FIBER VAULT (4) (4)
(4)(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(4)
(2)
(4)
(2)
NOTES:
GENERAL ARRANGEMENT OF SYSTEM AND WORK
DRAWING IS DIAGRAMMATIC AND INDICATES
07/21/09A. CARLOS
ACA 09/07/12 NDP
1
E
C 2 3
OMITTED MTTV, TVM, DVM, REVISE NOTE 1 & TVM PAD
E E
C C
E E
C
E
C C
E E
C
E
C
E
C
6.
5.
4.
3.
2.
1.
ACB 07/10/15 NDPREVISED LIGHT POLE SYMBOLS, ADD NOTE 6
ACCESS POINT
COMMERCIAL POWER
VAULT
TELCO
SHELTER
COMMUNICATIONS
MESSAGE SIGN LOCATIONS.
REFER TO ES3503 FOR CAMERA, SPEAKER AND LED
TVM PAD LOCATION VARIES BY STATION
FOR ADDITIONAL NOTES AND LEGEND SEE ES3001.
DRAWINGS ES9400 THRU ES9440.
FOR COMMUNICATION SHELTER SEE COMMUNICATIONS STANDARD
ARE ENERGIZED FROM THE COMMUNICATIONS SHELTER.
PUBLIC ADDRESS AND LED MESSAGE SIGNS (PA & LED)
STATION POWER SOURCE. (SEE ES3405-01 & ES3405-02)
ALL TICKET VENDING MACHINES ARE ENERGIZED FROM THE
LVM
CENTER PLATFORMMETROLINK STATION CONDUIT LAYOUT
ES3401-02
2 OF 2
NTS
3401
B
1"C1"C
1"C
1"C
1"C
1"C
2"C
1"C
2"C
17"L x 11"W x 12"D
COMMUNICATION PULL BOX
1"C
1"C
2"C
1"C
1"C
GROUND LEVEL
CONCRETE PLATFORM
CAST IN PLACE
17"Lx11"Wx12"D
POWER PULL BOX
FOUNDATION
LIGHT STANDARD
1"C
CANOPY BASE
AS REQUIRED
3"3"
3"
3"
3'-
0" (
MIN.)
WARNING TAPE
PROVIDE RED
REQUIRED
INDICATED AND/OR
OF CONDUITS AS
SIZE AND QUANTITY
2"
CL
EA
R
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 8:51:09 AM5/12/2016 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3402-01_revB.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
4"C SPARE
2"C C/F
2"C-D/T
2"C PA/LED
STATION POWER - 2"C -P
TO SERVICE CABINET
PA/L
ED
P
2"C
STATION POWER - 2"C -P
1" C
2"C
SPARE 4"C
SPARE 4"C
SPARE 4"C
SPARE 4"C
2"C
2"C
2"C D/T
C/F
D/T
PA/LED
C/F 2"C
2"C
2"C
P 2"CP2"C
2"C
P 2"CP2"C
2"C
2"C CCTV
CCTV/P 2"C -P
2"C 2"CCCTV/P CCTV/P
2"CCCTV2"C CCTV
LED/P LED/P
LED/P
LED/P
POWER PULL BOX
TO COMMUNICATIONS SHELTER
CCTV/P
2"C
2"C
2"C
2"C
LED/P
P
P
2"C
2"C
2"C
2"C
2"C
2"C
2"C
2"C
2"C
2"C
2"C
2"C
C/F
CCTV
PA/LED
D/T
BASE
LIGHT POLEBASE
CANOPY
PULLBOX
COMM
PULLBOX
COMM
PULLBOX
POWER
PULLBOX
POWER
PA/LED
LE
D/P
CCTV
CCTV P
A/LE
D
LE
D/P
P
P
SPARE 4"C
SPARE 4"C
SPARE 4"C
SPARE 4"C
CCTV/P
2"C
2"C
2"C
2"C
LED/P
P
2"C
2"C
2"C
2"C
2"C
2"C
2"C
2"C
2"C
2"C
2"C
2"C
C/F
CCTV
PA/LED
D/T
BASE
LIGHT POLE
PULLBOX
COMM
PULLBOX
COMM
PULLBOX
POWER
PULLBOX
POWER
PA/LED
CCTV
LE
D/P
P
SPARE 4"C
SPARE 4"C
SPARE 4"C
SPARE 4"C
LV
M/P
P
D/T
LED/P
PA/LED
COMM. SHELTER POWER - 2"C LED/P
TVM PAD
CANOPY BASE POWERCOMMS
NOTES:
TYPICAL SECTION THRU SINGLE PLATFORM
AT LIGHT POLE AND CANOPY
CONDUIT LAYOUT
AT EMERGENCY MANAGEMENT PANEL
CONDUIT LAYOUT
AT TVM PAD
CONDUIT LAYOUT
CC
TV P
A/LE
D
04/01/03A. CARLOS
ACA
MONITOR
LED VIDEO
07-10-15 REVISED CONDUIT LAYOUT AT TVM PAD NDP
LVM/P
SIDE PLATFORM
CONDUIT LAYOUT DETAILS
METROLINK STATION
ES3402-01
1 OF 2
NTS
3402
B
NOTES:
FOR NOTES AND LEGEND SEE ES3001.
TO TVM PAD VARIES BY LOCATION.
ORIGINATION OF POWER AND COMMUNICATION FEEDS
OF DESIGN.
CONDITIONS AND TO BE DETERMINED AT THE TIME
CONDUITS WILL VARY DUE TO SITE SPECIFIC
FOR REFERENCE ONLY. ACTUAL LOCATION OF
LOCATION OF CONDUITS ON THIS DRAWING SHOWN
3.
2.
1.
TYPICAL CONDUIT DUCT BANK DETAIL
7.
6.
5.
4.
3.
2.
1.
ACB 04-07-16 NDPADDED DUCT BANK DETAIL
BE COMPLETED.
BACKFILLING OF THE TRENCH EXCAVATION MAY THEN
TRENCH 2 HOURS ATER THE CONCRETE IS POURED.
SHALL BE PLACED OVER THE CONCRETE IN A
SIX INCHES OF WELL-DAMPENED CONDUIT BEDDING
ASTMC494 TYPE A.
YARD (2 SACKS); AND WATER REDUCING ADMIXTURE
CEMENT CONTENT OF 190 POUNDS PER CUBIC
MINIMUM SLUMP OF 2" AND MAXIMUM OF 4";
CONCRETE FOR CONDUIT PROTECTION SHALL HAVE
SPACING.
EVERY 5FT TO SUPPORT AND MAINTAIN UNIFORM
PROVIDE PREFABRICATED PLASTIC CONDUIT SPACERS
MOISTURE FROM ENTERING.
SEAL ALL CONDUIT OPENINGS TO PREVENT
AS PER TERRAIN, SOIL AND EXISTING CONDITIONS.
CONTRACTOR SHALL ARRANGE THE CONDUIT
OF 2" CLEAR.
BETWEEN CONDUITS SHALL BE A MINIMUM
VERTICAL AND HORIZONTAL SEPARATION
ENCASED WITH MINIMUM 3" ENVELOPE.
ALL CONDUITS SHALL BE RED CONCRETE
1"C
1"C 1"C
1"C
1"C
1"C
2"C
1"C
1"C
1"C
2"C
17"L x 11"W x 12"D
COMMUNICATION PULL BOX
17"Lx11"Wx12"D
POWER PULL BOX
CONCRETE PLATFORM
CAST IN PLACE
1"C
1"C
2"C
FOUNDATION
LIGHT STANDARD
BASE
CANOPYAS REQUIRED
3"3"
3"
3"
3'-
0" (
MIN.)
WARNING TAPE
PROVIDE RED
REQUIRED
INDICATED AND/OR
OF CONDUITS AS
SIZE AND QUANTITY
2"
CL
EA
R
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 8:53:40 AM5/12/2016 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3402-02_revB.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
4"C SPARE
2"C C/F
2"C D/T
2"C PA/LED
TO SERVICE CABINET
PA/L
ED
P
2"C
1" C
2"C
SPARE 4"C
SPARE 4"C
SPARE 4"C
SPARE 4"C
2"C
2"C
2"C D/T
PA/LED
C/F
D/T
PA/LED
C/F 2"C
2"C
2"C
P 2"CP2"C
2"C
P 2"CP2"C
2"C
2"C CCTV
2"C 2"CCCTV/P CCTV/P
2"CCCTV2"C CCTV
2"C2"C2"C2"C
2"C2"C2"C2"C
2"C2"C2"C2"C
2"C2"C2"C2"C
2"C2"C2"C2"C
2"C2"C2"C2"C
2"C2"C2"C2"C
2"C2"C2"C2"C
2"C2"C2"C2"C
2"C2"C2"C2"C
2"C2"C2"C2"C
2"C2"C2"C2"C
TVM PAD
12
LE
D/P
PO
WER
LE
D/P
PA/LE
D
CC
TV
POWERLVM/P
D/T
LV
M
LED/P LED/P
LED/P
LED/P
CCTV/P 2"C
STATION POWER - 2"C
STATION POWER - 2"C
POWER PULL BOX
TO COMMUNICATIONS SHELTER
SPARE 4"C
SPARE 4"C
SPARE 4"C
SPARE 4"C
SPARE 4"C
SPARE 4"C
SPARE 4"C
SPARE 4"C
LED/P 2"C
AT LIGHT POLE AND CANOPY
CONDUIT LAYOUT
AT EMERGENCY MANAGEMENT PANEL
CONDUIT LAYOUT
AT TVM PAD
CONDUIT LAYOUT
NOTES:
TYPICAL SECTION THRU CENTER PLATFORM
BASE
LIGHT POLEBASE
CANOPY
PA/LED
POWERPOWER
C/FCCTV
D/T
LED/PCCTV/P
PULLBOX
COMMUNICATIONS
PULLBOX
COMMUNICATIONS
LE
D/P
A
LE
D/P
CCT
V
PO
WER
LE
D/P
AC
CT
V
PO
WER
LE
D/P
PULLBOX
POWER
PULLBOX
POWER
PULLBOX
POWER
PULLBOX
POWER
PULLBOX
COMMUNICATIONS
PULLBOX
COMMUNICATIONS
BASE
LIGHT POLE
BASE
CANOPY COMM.
POWER
PA/LED
C/FCCTV
D/T
CCT
VP
A/LE
D
LVM/PPOWER
LED/PCCTV/P
07/21/09
ACA
MONITOR
LED VIDEO
07-10-15 REVISED CONDUIT LAYOUT AT TVM PAD NDP
A. CARLOS
CENTER PLATFORMCONDUIT LAYOUT DETAILS
METROLINK STATION
ES3402-02
2 OF 2
NTS
3402
B
FOR NOTES AND LEGEND SEE ES3001.
DETERMINED AT THE TIME OF DESIGN.
TO SITE SPECIFIC CONDITIONS AND TO BE
LOCATION OF CONDUITS WILL VARY DUE
SHOWN FOR REFERENCE ONLY. ACTUAL
LOCATION OF CONDUITS ON THIS DRAWING
2.
1.NOTES:
TYPICAL CONDUIT DUCT BANK DETAIL
7.
6.
5.
4.
3.
2.
1.
BE COMPLETED.
BACKFILLING OF THE TRENCH EXCAVATION MAY THEN
TRENCH 2 HOURS ATER THE CONCRETE IS POURED.
SHALL BE PLACED OVER THE CONCRETE IN A
SIX INCHES OF WELL-DAMPENED CONDUIT BEDDING
ASTMC494 TYPE A.
YARD (2 SACKS); AND WATER REDUCING ADMIXTURE
CEMENT CONTENT OF 190 POUNDS PER CUBIC
MINIMUM SLUMP OF 2" AND MAXIMUM OF 4";
CONCRETE FOR CONDUIT PROTECTION SHALL HAVE
SPACING.
EVERY 5FT TO SUPPORT AND MAINTAIN UNIFORM
PROVIDE PREFABRICATED PLASTIC CONDUIT SPACERS
MOISTURE FROM ENTERING.
SEAL ALL CONDUIT OPENINGS TO PREVENT
AS PER TERRAIN, SOIL AND EXISTING CONDITIONS.
CONTRACTOR SHALL ARRANGE THE CONDUIT
OF 2" CLEAR.
BETWEEN CONDUITS SHALL BE A MINIMUM
VERTICAL AND HORIZONTAL SEPARATION
ENCASED WITH MINIMUM 3" ENVELOPE.
ALL CONDUITS SHALL BE RED CONCRETE
ACB 04-7-16 NDPADDED DUCT BANK DETAIL
(3) 2"C
(6) 2"C
NOTE 2
(1) 3"C
NOTE 3
2"C
4"C
2"CNOTE 2
2" C
SEE NOTE 5
SEE NOTE 5
(6) 2"C
(1) 3"C
NOTE 3
2"C
2"C
NOTE 1
NOTE 1
NOTE 1
2" C
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 12:36:50 PM7/23/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3403_revA.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
4"C
TO PLATFORM
SPARE
(3) 2"C
TO PLATFORM
TO PLATFORM
4"CSPARE
4"CSPARE
4"CSPARE
SEE NOTE 4
4"CSPARE
4"CSPARE
4"CSPARE
4"CSPARE
SEE NOTE 4
4"CSPARE
4"CSPARE
4"CSPARE
4"CSPARE
SEE NOTE 4
(3) 2"CSINGLE PHASE
100 AMP SVS 120/240V
EDISON METER PANELS
SINGLE PHASE
100 AMP SVS 120/240V
EDISON METER PANELS
(1) 3"CLED/P
PA/LED/DTPA/LED/DT
LED/P
LED/P
LED/P
PA/LED/DT
LE
D/
P
LE
D/
P
FOR ADDITIONAL NOTES AND LEGEND SEE ES3001.
ES9400 THRU ES9440.
FOR COMMUNICATIONS SHELTER SEE COMMUNICATIONS STANDARD DRAWINGS
SPARE CONDUIT TO RUN LENGTH OF PLATFORM AND STUBBED OFF AT END.
SEPARATE METER SERVICE 100 AMP/ 120/ 240V SINGLE PHASE.
11" x 17" PULL BOX.
4'-0" x 4'-0" x 4'-0" DEEP VAULT WITH GALVANIZED COVER.
6.
5.
4.
3.
2.
1.
CENTER PLATFORMS
SIDE PLATFORMS
NOTES:
FIBER VAULT
3"C STUB TO 2"C (3)
TELCO VAULT
3"C TO
TELCO VAULT
3"C TO
FIBER VAULT
3"C STUB TO
E
E
V
V
E
V
COMM. SHELTER
COMM. SHELTER
04/01/03A. CARLOS
ACA 09-07-12 REVISED DRAWING TITLE NDP CONDUIT LAYOUTCOMMUNICATIONS SHELTER
SINGLE TENNANT
ES3403
1 OF 1
NTS
3403
A
(4) 2"C
(6) 2"C
NOTE 3
2"C
(6) 2"C
(2) 3"C
NOTE 3
2"C
NOTE 2
(2) 3"C
(2) 2"C
(4) 2"C
(4) 2"C
(4) 2"C
(2) 2"C
(2) 3"C
(4) 2"C
(2) 3"C
2"C 2"C
4"C
2"C
2"C
2" CLED/P
CCTV/P
NOTE 1
NOTE 1NOTE 1
NOTE 1
SEE NOTE 5SEE NOTE 5
(4) 2"C
NOTE 2NOTE 2
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 12:36:51 PM7/23/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3404_revA.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
(4) 2"C
TO PLATFORM
TO PLATFORM
4"CSPARE
4"CSPARE
4"CSPARE
4"CSPARE
SEE NOTE 4
4"CSPARE
4"CSPARE
4"CSPARE
4"CSPARE
SEE NOTE 4
(4) 2"C
SINGLE PHASE
100 AMP SVS 120/240V
EDISON METER PANELS
(2) 3"C
TO FIBER VAULT
3"C STUB
TO PLATFORM
4"CSPARE
4"CSPARE
4"CSPARE
4"CSPARE
SEE NOTE 4
SINGLE PHASE
100 AMP SVS 120/240V
EDISON METER PANELS
(4) 2"C - (4 TOTAL)
2"C - (4 TOTAL)
2"C
LED/PCCTV
PA/LED/DT/CCTV
PA/LED/DT/CCTV
LED/P
LE
D/
P
PA/LED/DT/CCTV
POWER
COMM. SHELTERCOMM. SHELTER
FOR ADDITIONAL NOTES AND LEGEND SEE ES3001.
EXISTING STATIONS ARE SINGLE TENANT, NEW STATIONS ARE SHARED TENANT
ES9400 THRU ES9440.
FOR COMMUNICATIONS SHELTER SEE COMMUNICATIONS STANDARD DRAWINGS
SPARE CONDUIT TO RUN LENGTH OF PLATFORM AND STUBBED OFF AT END.
SEPARATE METER SERVICE 100 AMP/ 120/ 240V SINGLE PHASE.
11" x 17" PULL BOX.
4'-0" x 4'-0" x 4'-0" DEEP VAULT WITH GALVANIZED COVER.
7.
6.
5.
4.
3.
2.
1.
PLATFORM
SINGLE/CENTER DOUBLE PLATFORM
NOTES:
FIBER VAULT
3"C STUB TO
TELCO VAULT
3"C TO
FIBER VAULT
3"C STUB TO
TELCO VAULT
3"C TO
E
V
V
E
E
V
E
E
V
V
11/07/08A. CARLOS
ACA 09-07-12 REVISED DRAWING TITLE NDP CONDUIT LAYOUTCOMMUNICATIONS SHELTER
SHARED TENNANT
ES3404
1 OF 1
NTS
3404
A
1" C
1" C 2" C
1" C
2" C
2" C
1" C
1" C
2" C
2" C
1" C
1" C
CANOPY BASE CANOPY BASE
1" C
CANOPY BASE
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 12:36:51 PM7/23/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3405-01_revB.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
EMP
1" C
CC
TV
D/
T
PA/
LE
D
D/T
P
TDD
D/
T
P
4
4
3
TVMP
D/T
P
TVM
3
P
P
D/T
4
ET
D/T
AND ES3401
SEE PLATFORM PLAN
FOR CONTINUATION OF CONDUIT RUNS
P
2
1
LE
D/
P
LV
M/
P
LV
MC
E
T
LEGEND & NOTES
04/01/03A. CARLOS
ACA 09-21-12 NDP
P
P
LVM
REVISE TVM DIAGRAM, OMIT MTTV DIAGRAM & NOTES
1" C
4
3
2
1
FOR ADDITIONAL NOTES AND LEGEND SEE ES3001
INDICATES FRONT FACE OF INSTALLED EQUIPMENT
CROUSE HINDS "WJBF060404" OR APPROVED EQUAL
6" X 4" X 4" DEEP WITH BARRIER AS INDICATED,
CHECKERED COVER SIDEWALK JUNCTION BOX
CROUSE HINDS "WJBF120806" OR APPROVED EQUAL
12" X 8" X 6" WITH BARRIER AS INDICATED,
CHECKERED COVER SIDEWALK JUNCTION BOX
LOGO
PULL BOX - 17"L X 11"W X 12" D WITH "COM"
LOGO
PULL BOX - 17"L X 11"W X 12"D WITH ELECTRIC
ACB 07-10-15 NDPREMOVED JUNCTION BOX, NOTE 5
TVM PAD (COMPLETE CONFIGURATION)
METROLINK STATION
ES3405-01
1 OF 2
NTS
3405
B
DP JBOX
12" x 8" x 6"
1'-6" 3'-0" 3'-6" MIN
2"C
1'-
0"
4'-6"
D/T 2" C
1'-
0"
1'-
6"
BACKBOARD
2"C2"CTVM TVM
2"C
TVM PAD
PULL BOX, 2 ON
BOTTOM OF PULL - BOXES
CONNECTIONS STUBBED INTO
2"C
1"C
LOCATIONS OF PULL - BOXES
PLATFORM PLAN FOR EXACT
PULL - BOXES ON PLATFORM SEE
CANOPY BASE
D/T-2" C
TVM FOOTPRINT
TVM FOOTPRINT
OBSTRUCTION
NEAREST SIDEANY BACK OBSTRUCTION
12" MIN. CLEARANCE TO
OBSTRUCTION
NEAREST SIDE
TVM FOOTPRINT
SHELTER
COMMUNICATIONS
DP JBOX
12" x 8" x 6"
ENTIRE PAD, AREA UNDER TVM
12" MIN., CONCRETE THICKNESS
COMM. SHELTER
D/T-2" C FROM
P-2" C
5'-0"
MONITOR
LED VIDEO
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 12:36:52 PM7/23/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3405-02_revB.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
CC
TV
PA/
LE
D
P
E
C
P
D/T
3
3
TELCO
TVM
P
4
HOLD
MIN.
MIN.
MIN.
MIN.
P D/
T
D/TD/TD/T
LV
M
LE
D/
P
LV
M/
P
TVM (ADDITIONAL)
TVMTVM CC
NOTES & LEGEND:
04/01/03A. CARLOS
ACA
PANEL
FROM STATION POWER
P-2" C (FROM P-PULLBOX)
DETAIL A
D/T
09-07-12 REVISE CONDUIT DIAGRAMS & DETAIL "A" NDP
LVM
1"C
2
1
(CROUSE HINDS WJBF040404 OR APPROVED EQUAL)
INDICATES FRONT FACE OF EQUIPMENT
FOR ADDITIONAL NOTES AND LEGEND SEE ES3001
HINDS "WJBF060404" OR APPROVED EQUAL.
6"x4"x4" DEEP WITH BARRIER AS INDICATED, CROUSE
CHECKERED COVERED SIDEWALK JUNCTION BOX
CHECKERED COVER SIDEWALK JUNCTION BOX 12"x8"x6"
PULL BOX - 17"Lx11"Wx12" D WITH "COM" LOGO
PULL BOX - 17"Lx11"Wx12"D WITH ELECTRIC LOGO
5
4
3
2
1
ACB 07-10-15 NDPREVISE CONDUIT DIAGRAMS, DETAIL "A" AND NOTES
TVM PAD (MINIMUM CONFIGURATION)
METROLINK STATION
ES3405-02
2 OF 2
NTS
3405
B
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 12:36:52 PM7/23/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\New Stds - in progress\ES3501-01.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
06/30/15
XXX 00-00-00
COMMUNICATION SHELTER
TO BACK OFFICE
SENSOR CABLE
AMBIENT NOISE
2 WIRE AUDIO
2 WIRE AUDIO
RS422/485
12-STRAND MMFO
CAT 6
CAT 6
AUDIO CABLE
3.5 mm
CAT 6
CABLE TO LCD
MMFO PATCH
SEE SHEET 2
SEE SHEET 3
SEE SHEET 4
SPEAKERS
SENSOR
NOISE
AMBIENT
ETHERNET SWITCH
CONTROLLER
PC / STATION
CONTROLLER
PRIORITY
AUDIO AMPLIFIER
TO RS422/485
IC ETHERNETFOPP
ROUTER
EXISTING
LED MESSAGE SIGN
MONITOR
LED VIDEO
CIS FOR EXISTING STATIONS
REVISION XX
HDR/A. CARLOS
ES3501-01
- 1 OF 4
NTS
3501
FOR EXISTING STATIONS
CUSTOMER INFORMATION SYSTEM (CIS)
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 12:36:53 PM7/23/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\New Stds - in progress\ES3501-02.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
06/30/15
XXX 00-00-00 REVISION XX
HDR/A. CARLOS
AMBIENT NOISE SENSOR CABLE
AUDIO AMPLIFIER
2 WIRE AUDIO FROM
SPEAKER SETUP PER PLATFORM
TO NEXT SPEAKERS SPEAKERSSPEAKERS
SENSOR
NOISE
AMBIENT
SHELTER
COMMUNICATION
SPEAKER DIAGRAM
ES3501-02
- 2 OF 4
NTS
3501
SPEAKER DIAGRAM
FOR EXISTING STATIONS
CUSTOMER INFORMATION SYSTEM (CIS)
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 12:36:53 PM7/23/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\New Stds - in progress\ES3501-03.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
06/30/15
XXX 00-00-00 REVISION XX
HDR/A. CARLOS
RS422/485
SHELTER
COMMUNICATION
RS422/485
RS422/485
OUTPUT
RS422/RS485
INPUT
RS422/RS485
OUTPUT
RS422/RS485
INPUT
RS422/RS485
CONTACT
RELAY
STROBE
120 VAC FOR
CONTACT
RELAY
STROBE
120 VAC FOR
LED SETUP PER PLATFORM
TO NEXT LED MESSAGE SIGN
LED MESSAGE SIGN DIAGRAM
ES3501-03
- 3 OF 4
NTS
3501
LED MESSAGE SIGN DIAGRAM
FOR EXISTING STATIONS
CUSTOMER INFORMATION SYSTEM (CIS)
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 12:36:54 PM7/23/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\New Stds - in progress\ES3501-04.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
06/30/15
XXX 00-00-00 REVISION XX
HDR/A. CARLOS
12-STRAND MMFO
12-STRAND MMFO
SHELTER
COMMUNICATION
12-STRAND MMFO
HDMI
CAT6
CABLE
PATCH
MMFOTO HDMI
NMP ETHERNET
ETHERNET
MC FO TOFOPP
HDMI INPUT
TO HDMI
NMP ETHERNET
ETHERNET
MC FO TO
CAT6
HDMIHDMI INPUT
CABLE
PATCH
MMFOFOPP
LED VIDEO MONITOR DIAGRAM
TO ADDITIONAL LED VIDEO MONITOR
ES3501-04
- 4 OF 4
NTS
3501
LED VIDEO MONITOR DIAGRAM
FOR EXISTING STATIONS
CUSTOMER INFORMATION SYSTEM (CIS)
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 12:36:54 PM7/23/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\New Stds - in progress\ES3502-01.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
06/30/15
XXX 00-00-00 REVISION XX
HDR/A. CARLOS
TO BACK OFFICE
COMMUNICATION SHELTER
SENSOR
NOISE
AMBIENT
SPEAKERS
SENSOR CABLE
AMBIENT NOISE
SPEAKERS
ROUTER
EXISTING
CAT 6
CAT 6
AUDIO CABLE
3.5 mm
2 WIRE AUDIO
12-STRAND MMFO
2 WIRE AUDIO
2 WIRE AUDIO
12-STRAND MMFO
CONTROLLER
PRIORITYFOPP
CONTROLLER
PC/STATION
DETECTOR/SWITCH
AUDIO PRESENCE
WITH SFP
ETHERNET SWITCH
CONVERTER
MODULAR MEDIA
AMPLIFIER #1
AUDIO
AMPLIFIER #2
AUDIO
SEE SHEET 2
SEE SHEET 4
SEE SHEET 3
CIS FOR NEW STATIONS
2 WIRE AUDIOLED MESSAGE SIGN
MONITOR
LED VIDEO
MESSAGE SIGN
CABLE TO LED
MMFO PATCH
VIDEO MONITOR
CABLE TO LED
MMFO PATCH
ES3502-01
- 1 OF 4
NTS
3502
FOR NEW STATIONS
CUSTOMER INFORMATION SYSTEM (CIS)
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 12:36:54 PM7/23/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\New Stds - in progress\ES3502-02.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
06/30/15
XXX 00-00-00 REVISION XX
HDR/A. CARLOS
SPEAKER SETUP PER STATION
TO NEXT SPEAKERS
SENSOR
NOISE
AMBIENT AMBIENT NOISE SENSOR CABLE
SHELTER
COMMUNICATION
SPEAKERSSPEAKERS
TO NEXT SPEAKERS SPEAKERSSPEAKERS
AUDIO AMPLIFIER #1
2 WIRE AUDIO FROM
AUDIO AMPLIFIER #2
2 WIRE AUDIO FROM
SPEAKER DIAGRAM
ES3502-02
- 2 OF 4
NTS
3502
SPEAKER DIAGRAM
FOR NEW STATIONS
CUSTOMER INFORMATION SYSTEM (CIS)
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 12:36:55 PM7/23/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\New Stds - in progress\ES3502-03.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
06/30/15
XXX 00-00-00 REVISION XX
HDR/A. CARLOS
LED MESSAGE SIGN DIAGRAM
LED SETUP PER PLATFORM
SHELTER
COMMUNICATION
STROBE
120 VAC FOR
RELAY CONTACT
STROBE
120 VAC FOR
RELAY CONTACT
RS422/485
12-STRAND MMFO
RS422/485
CONNECTION
RJ45
ETHERNET
MC FO TOFOPP
OUTPUT
RS422/485
INPUT
RS422/485
OUTPUT
RS422/RS485
CABLE
PATCH
MMFO
TO NEXT LED MESSAGE SIGN
ES3502-03
- 3 OF 4
NTS
3502
LED MESSAGE SIGN DIAGRAM
FOR NEW STATIONS
CUSTOMER INFORMATION SYSTEM (CIS)
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 12:36:55 PM7/23/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\New Stds - in progress\ES3502-04.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
06/30/15
XXX 00-00-00 REVISION XX
HDR/A. CARLOS
SHELTER
COMMUNICATION
12-STRAND MMFO
12-STRAND MMFO
12-STRAND MMFO
TO HDMI
NMP ETHERNET
CAT6
HDMIHDMI INPUT
ETHERNET
MC FO TO
CABLE
PATCH
MMFOFOPP
TO HDMI
NMP ETHERNET
CAT6
HDMI
ETHERNET
MC FO TO
HDMI INPUT
CABLE
PATCH
MMFOFOPP
LED VIDEO MONITOR DIAGRAM
TO ADDITIONAL LED VIDEO MONITORS
ES3502-04
- 4 OF 4
NTS
3502
LED VIDEO MONITOR DIAGRAM
FOR NEW STATIONS
CUSTOMER INFORMATION SYSTEM (CIS)
‚"‚"
6"2"
12"
15"
5"
6"
21"
10.44
"
60"
60"
60"
6"
2"
4"
5"
2'-4"
1"1'-1"1'-1"1"
"2
11
"2
11
3"
"8
72
"16
11
"16
91"
"8
72
"1613
"2
1
3"
"211 "2
11
(BLACK)
POWDER COAT FINISH
…" DIA.
2"
"32
3
"21
BOLT TYP (2)
SEE NOTE 1 & 2
SEE NOTE 1 & 2
FOR BRACKET DETAILS
SEE DRAWING ES3508 (TYP.)
FOR BRACKET DETAILS
SEE DRAWING ES3508 (TYP.) FOR BRACKET DETAILS
SEE DRAWING ES3508 (TYP.)
LED
LED LED
LIGHT POLE
LIGHT POLEBOLT TYP (2)
BOLT TYP (2)
BOLT TYP (2)
BOLT TYP (2)
BOLT TYP (2)
BOLT TYP (4)
BOLT TYP (4)
SEE NOTE 1 & 2
SUNSHIELD SUPPORT
SUNSHIELD SUPPORT
SUNSHIELD SUPPORT
MOUNTING PLATE
MOUNTING PLATE
MOUNTING PLATE
(TYP)1" FLEX CONDUIT
SEE NOTE 3
SEE NOTE 3
FOPPFOPP FOPP
MOUNTING PLATE
SEE NOTE 3
(TYP)1" FLEX CONDUIT
(TYP)1" FLEX CONDUIT
MOUNTING PLATE MOUNTING PLATE
3 REQUIRED3/8" DIA. (TYP.)
TYP.5/16" RAD.
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:15:33 AM11/24/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3503_revA.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
SUNSHIELD 3D VIEW SUNSHIELD SIDE VIEW
SUNSHIELD FRONT VIEW
SUNSHIELD BACK VIEW
NOTES
5.
4.
3.
2.
1.
.CONDUIT ENTRY WILL BE SHOWN WHEN COMPONENT PART NUMBERS ARE FINALIZED
ON SIGN MAXIMUM DIMENSIONS OF 55"W x 17"H x 11"D.
DIMENSIONS FOR ALL DETAILS SHALL NOT BE EXCEEDED. DIMENSIONS ARE BASED
SUNSHIELD SUPPORT NOT SHOWN FOR CLARITY.
SUNSHIELD SUPPORT TO BE WELDED TO SUNSHIELD.
SUNSHIELD AND STROBE LIGHT ARE NOT SHOWN.
A
08/12/09
ACA 09-28-15
THIC
K
4.
3.
2.
1.
A
ELEVATION A
OPP.
TYP.
ELEVATON
PLAN
NOTES:
-
-
(SINGLE SIDED)LED MOUNTING DETAIL ELEVATION
(DUAL SIDED)LED MOUNTING DETAIL ELEVATION
(SINGLE SIDED)LED MOUNTING DETAIL TOP VIEW
(DUAL SIDED)LED MOUNTING DETAIL TOP VIEW
LED MODEL
ACTUAL BRACKET DIMENSION TBD PENDING APPROVED
POWDER COAT FINISH TO BE GLOSS BLACK
GRIND ALL SHARP EDGES SMOOTH
BRACKET TO BE MADE FROM ‘" THICK SHEET METAL.
SYSTRA/A. CARLOS
MOUNTING DETAILSLED MESSAGE SIGN
ES3503
1 OF 1
NTS
3503
REVISE DRAWING NUMBER NDP
08/12/09
ACA 09-07-12 REVISE NOTE 2, TVM PAD DIAGRAM AND DRAWING TITLE NDP
NOTES:
ACB 07-10-15 NDPREVISE CONTENT, REVISE TITLE
4.
3.
2.
1.
MOUNTING DETAILS
LED VIDEO MONITOR ASSEMBLY
ES3504-01
1 OF 2
NTS
3504
D
ACC 09-28-15 NDPREVISE DRAWING NUMBER
6"
11'-
0"
10'-
4"
SUN SHIELD
DISPLAY ENCLOSURE
2-1" CONDUITS REQ'D
PLATFORM AS REQ'D
SAW CUT CONCRETE
TO LED VIDEO MONITOR
11" X 17"
COMM. PULLBOX
11" x 17"
PULL BOX
ELECTRICAL
"21
4'-1
SUN SHIELD
4'-0"
ENCLOSURE
TO PULLBOX
PLATFORM AS REQ'D
SAW CUT CONCRETE
3'-
0"
10'-
4"
MONITOR POST DETAIL: FRONT VIEWMONITOR POST DETAIL: SIDE VIEW
ISOMETRIC VIEW
ACD 06-03-16 NDPREVISED DETAILS
REMOVABLE CAP PLATE
A. CARLOS
11'-
0"
MIN.
DE
PT
H
ENCLOSURE
DISPLAY
AIR CONDITIONER
STEEL POST
6" SQUARE
SHEET 2 OF 2
FOUNDATION SEE
BASE PLATE &
SEE SHEET 2 OF 2.
2'-6" DIA. CONCRETE FOUNDATION
PAINT COLOR WILL BE SILVER.
UNLESS OTHERWISE SPECIFIED, ENCLOSURE AND SUPPORTS
WELDED, WATER TIGHT, WITH POLYESTER POWDER FINISH.
ENCLOSURE IS MARINE GRADE ALUMINUM, FORMED AND
POWDER PAINT FINISH.
MOUNTING POST IS CARBON STEEL WITH A POLYESTER
ASSEMBLY BY I.T.S. ENCLOSURES.
LED VIDEO MONITOR ENCLOSURE AND MOUNTING POST
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
$USER$ Date Plotted: $TIME$$DATE$ Plot Driver=> $PLTDRVL$ FileName=> $FILEL$
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
NOTES
07/10/15
ACA 09-07-12 REVISE TVM PAD DIAGRAM & DRAWING TITLE NDP
POST
TO PULL BOX
ANCHOR BOLTS DETAIL
FOUNDATION DETAIL
BASE PLATE BOLT PATTERN DETAIL
CONDUIT STUB-UP DETAIL
USE FOR METROLINK ENGINEERING STANDARD 3504.
OR GROUNDING CONDUCTOR.
ANCHOR BOLTS SHALL BE BONDED TO CONDUIT
FINISHED SURFACE OF FOUNDATION.
CONDUITS SHALL EXTEND 2" MAXIMUM ABOVE
3.
2.
1.
ACB 07-10-15 NDPREVISE CONTENT, REVISE TITLE
HDR / A. CARLOS
MOUNTING POST FOUNDATION DETAIL
LED VIDEO MONITOR ASSEMBLY
ES3504-02
2 OF 2
NTS
3504
D
±3"
MA
X
±2"
MIN.
0.5
MA
X
1'-
6"
MIN.
2'-0"
"16
13
2'-
4
3'-
0"
MIN.
DE
PT
H
2'-6" DIA
FINISH GRADEBASE PLATE
THREADED STUB BOLT FOUNDATION
BASE PLATE &
ST
AN
DA
RD
BO
LT
EM
BE
DM
EN
T
SA
ME
AS
TO LED VIDEO MONITOR
ACC 09-28-15 NDPREVISE DRAWING NUMBER
.94 x 1.88 SLOT (4)
BOLTS
BO
LT
S 1'-
0"
8"
8"
1'-0"SEE FOUNDATION DETAIL
CONCRETE FOUNDATION
2'-6" DIA.
FOUNDATION
CIS-LVM
ACD 06-03-16 NDPREVISED BASE PLATE BOLT PATTERN DETAIL
BASE PLATE
•" x 12" x 12"
DIA.
ƒ"
OR 4" 90° BEND, TOTAL 4
LENGTH DOES NOT INCLUDE 2"
6", WITH 2 NUTS AND 2 WASHERS EACH.
ƒ" DIA X 1'-6" ANCHOR BOLTS THREAD
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
$USER$ Date Plotted: $TIME$$DATE$ Plot Driver=> $PLTDRVL$ FileName=> $FILEL$
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
LIGHT POLE
CANOPY
12'-
0"
NO
MIN
AL
STROBE
SPEAKER
CIS SIGN
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> CARLOSA Date Plotted: 8:29:27 AM6/7/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3505.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
NOTES:
LANDSCAPING
C
SIDE PLATFORM
TRACK
4.
3.
2.
1.
ES3505
- 1 OF 1
350512/24/09
--
A. CARLOS
NTS
SIDE PLATFORMS
CIS MOUNTING LOCATION
(AS APPLICABLE).
FOR ADDITIONAL PLATFORM INFORMATION NOT SHOWN, SEE DRAWINGS ES3201 & ES3202
SINGLE OR DOUBLE SIDED CIS SIGN AND SPEAKERS AS APPLICABLE.
THE LED SIGN SHALL BE INSTALLED APPROXIMATELY ONE FOOT LOWER THAN THE SPEAKER.
TO MAXIMIZE VISIBILITY AND SOUND DISTRIBUTION, AND VARIES BY STATION. THE TOP SIDE OF
PLACEMENT OF CIS SIGNS, STROBES AND SPEAKERS SHALL BE LOCATED BY THE CONTRACTOR
LIGHT POLE AND CANOPY SHOWN AS REFERENCE ONLY ACTUAL DESIGN VARIES BY STATION.
- - -
C
12'-
0"
NO
MIN
AL
LIGHT POLE
CANOPY
STROBE
SPEAKER
CIS SIGN
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> CARLOSA Date Plotted: 8:29:27 AM6/7/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3506.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
CENTER PLATFORM
NOTES:
OF PLATFORM
ES3506
1 OF 1
350612/24/09A. CARLOS
NTS
CENTER PLATFORMS
CIS MOUNTING LOCATION
(AS APPLICABLE).
FOR ADDITIONAL PLATFORM INFORMATION NOT SHOWN, SEE DRAWINGS ES3201 & ES3202
SINGLE OR DOUBLE SIDED CIS SIGN AND SPEAKERS AS APPLICABLE.
THE LED SIGN SHALL BE INSTALLED APPROXIMATELY ONE FOOT LOWER THAN THE SPEAKER.
TO MAXIMIZE VISIBILITY AND SOUND DISTRIBUTION, AND VARIES BY STATION. THE TOP SIDE OF
PLACEMENT OF CIS SIGNS, STROBES AND SPEAKERS SHALL BE LOCATED BY THE CONTRACTOR
LIGHT POLE AND CANOPY SHOWN AS REFERENCE ONLY ACTUAL DESIGN VARIES BY STATION.
4.
3.
2.
1.
-- - - - -
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> CARLOSA Date Plotted: 8:29:28 AM6/7/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3507_revE.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
MATERIALS LIST
07/21/09A. CARLOS
ACA 09-21-12 REVISED DRAWING TITLE NDP
ACB 12-24-14 REVISED MATERIALS LIST NDP
EXISTING STATIONS
ITEM DESCRIPTION MODEL NO.MANUFACTURERS
RECOMMENDED ITEM DESCRIPTION MODEL NO.MANUFACTURERS
RECOMMENDED
NEW STATIONS
ACC 07-10-15 REVISED MATERIALS LIST NDP
21.
20.
19.
18.
17.
16.
15.
14.
13.
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
TELEX
TRANSITION NETWORKS
CORNING
TRANSITION NETWORKS
DAKTRONICS
ITS ENCLOSURES
CORNING
CORNING
EATON INNOVATIVE TECHNOLOGY
EATON INNOVATIVE TECHNOLOGY
CORNING
CORNING
PERLE
SUPERLOGICS
DAVICOM
FEDERAL SIGNAL
VIEWSONIC
LG
BSS AUDIO
CROWN
HP
AMBIENT NOISE SENSOR
INTERFACE CONVERTER
LED VIDEO MONITOR/MESSAGE SIGNS
LED VIDEO MONITOR/MSF SIGNAL FPP
MODULAR MEDIA CONVERTER
LED MESSAGE SIGNS
BRACKETS
STAINLESS STEEL MOUNTING POST AND
T20 2000 BTU AIR CONDITIONER/ HEATER),
ENCLOSURE POST, BRACKETS, MOUNTS,
47" LED VIDEO MONITOR, INSULATION,
LED VIDEO MONITOR ENCLOSURE (INCLUDING
SPLICE MODULES
PIGTAIL MODULES
CLOSET CONNECTOR HOUSING
UPS
BATTERY
HOUSING
RACK MOUNT CONNECTOR
CENTER
ENVIRONMENTAL DISTRIBUTION
INTERFACE CONVERTER
STATION CONTROLLER
AUDIO PRESENCE DETECTOR
STROBE LIGHT
NETWORK MEDIA PLAYER
47" COMMERCIAL LED VIDEO MONITOR
PRIORITY CONTROLLER
AUDIO AMPLIFIER
ETHERNET SWITCH W/SFP
WP-300
SGFEB1014-120
SPH-01P
CPSMC 1810-200
AF-6300-16X9-12-A-S
STE-01230.9-00
STE-02810.9-00
CUSTOM MOUNT
VS-FS-4TLG-SLV
CCH SERIES
CCH SERIES
PW9130 L2000R-XL2US
PW9130N 3000REBM21
CCH-SERIES
CCH-040
IOLAN DS1
SL-1U-CTHG1-LA
DAPD-01
131DST
NMP-530, VS11681
47WX50MF
BLU-50
CTs 4200
HP1910
21.
20.
19.
18.
17.
16.
15.
14.
13.
12.
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
TELEX
TRANSITION NETWORKS
CORNING
TRANSITION NETWORKS
DAKTRONICS
ITS ENCLOSURES
CORNING
CORNING
EATON INNOVATIVE TECHNOLOGY
EATON INNOVATIVE TECHNOLOGY
CORNING
CORNING
PERLE
SUPERLOGICS
DAVICOM
FEDERAL SIGNAL
VIEWSONIC
LG
BSS AUDIO
CROWN
HP
WD-300
SGFEB1014-120
SPH-01P
CPSMC 1810-200
AF-6300-16X9-12-A-S
STE-01230.9-00
STE-02810.9-00
CUSTOM MOUNT
VS-FS-4TLG-SLV
CCH SERIES
CCH SERIES
PW9130 L2000R-XL2US
PW9130N 3000REBM21
CCH-SERIES
CCH-040
IOLAN DS1
SL-1U-CTHG1-LA
DAPD-01
131DST
NMP-530, VS11681
47WX50MF
BLU-16
CTs 4200
HP1910
AMBIENT NOISE SENSOR
INTERFACE CONVERTER
LED VIDEO MONITOR/MESSAGE SIGNS
LED VIDEO MONITOR/MSF SIGNAL FPP
MODULAR MEDIA CONVERTER
LED MESSAGE SIGNS
BRACKETS
STAINLESS STEEL MOUNTING POST AND
T20 2000 BTU AIR CONDITIONER/ HEATER),
ENCLOSURE POST, BRACKETS, MOUNTS,
47" LED VIDEO MONITOR, INSULATION,
LED VIDEO MONITOR ENCLOSURE (INCLUDING
SPLICE MODULES
PIGTAIL MODULES
CLOSET CONNECTOR HOUSING
UPS
BATTERY
HOUSING
RACK MOUNT CONNECTOR
CENTER
ENVIRONMENTAL DISTRIBUTION
INTERFACE CONVERTER
STATION CONTROLLER
AUDIO PRESENCE DETECTOR
STROBE LIGHT
NETWORK MEDIA PLAYER
47" COMMERCIAL LED VIDEO MONITOR
PRIORITY CONTROLLER
AUDIO AMPLIFIER
ETHERNET SWITCH W/SFP
CIS MATERIALS LIST
ES3507
1 OF 1
NTS
3507
E
ACD 09-28-15 REVISED DRAWING NUMBER NDP
ACE 05-31-17 REVISED DRAWING NUMBER LA
CENTER)
END (POINTED TOWARDS PLATFORM
SINGLE CAMERA AT PLATFORM
PA SPEAKERS
PLATFORM CENTER)
END (POINTED TOWARDS
SINGLE CAMERA AT PLATFORM
PLATFORM
STATION
(IF NO CANOPIES)
MIDDLE OF PLATFORM
BACK-TO-BACK CAMERAS AT
PA SPEAKERS
CENTER)
END (POINTED TOWARDS PLATFORM
SINGLE CAMERA AT PLATFORM
PA SPEAKERS
PLATFORM CENTER)
END (POINTED TOWARDS
SINGLE CAMERA AT PLATFORM
PLATFORM
STATION
PA SPEAKERS
CANOPIES (IF APPLICABLE)
SINGLE CAMERA IN BETWEEN
160'
160'
CIS SIGN
CIS SIGN
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> CARLOSA Date Plotted: 8:29:28 AM6/7/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3601_revB.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
12/24/09
ACA
A. CARLOS
09-28-15
NOTES:
B 1 OF 1
3601
NTS
(TYPICAL)
MOUNTING AND SPACING DETAILS
VIDEO SURVEILLANCE SYSTEM (VSS)
STATION PLATFORM WITH CANOPIES
DETAIL B: TYPICAL MOUNTING LOCATIONS ON
STATION PLATFORM WITHOUT CANOPIES
DETAIL A: TYPICAL MOUNTING LOCATIONS ON
TYP
TYP
REVISE DRAWING NUMBER NDP
ES3601
7.
6.
5.
4.
3.
2.
1.
CAMERA PREFERRED.
DUAL CAMERAS SHOWN FOR CLARITY, SINGLE 180/360 DEGREE
APPROVED BY SCRRA PRIOR TO INSTALLATION.
PLATFORM CAMERA MOUNTING LOCATIONS AND DETAILS TO BE
TYPE, UNLESS APPROVED OTHERWISE.
ALL PLATFORM CAMERAS SHALL BE OF THE PTZ (PAN-TILT-ZOOM)
MOUNTING DETAILS.
SEE DRAWING ES3505 AND ES3506 FOR CIS SIGN AND SPEAKER
COVERAGE AREA.
APPLICABLE. MOUNT CAMERAS AT A HEIGHT TO MAXIMIZE THE
PLATFORM CAMERAS TO BE MOUNTED ABOVE PA SPEAKERS, WHEN
LIGHT FIXTURE AS LED MESSAGE SIGNS AND/OR PA SPEAKERS.
PLATFORM CAMERAS TO BE MOUNTED ON THE SAME PLATFORM
BY LOCATION.
THIS DRAWING FOR REFERENCE ONLY. PLATFORM LAYOUT VARIES
ACB 05-31-17 REVISED ELEVATIONS AND NOTE 4 LA
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> CARLOSA Date Plotted: 8:29:29 AM6/7/2017 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3602_revA.dgn
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITYPRINCIPAL ENGINEER: DESIGN & ENGINEERING
06/30/15
ACA 09-28-15
NETWORK
SCRRA CAMERA
POE POE
POE
KVM CONSOLE
SWITCH
POE AGGREGATION
POE MIDSPAN INJECTOR
SYSTEM
RADIO
WIRELESS
SYSTEM
RADIO
WIRELESS
SWITCH
POE
(1-
PO
RT)
PO
E
SP
(1-
PO
RT)
PO
E
SP
POE
POE
(1-
PO
RT)
PO
E
SP
(1-
PO
RT)
PO
E
SP
POE
POE
FOPP FOPP
SWITCH
POE
(1-
PO
RT)
PO
E
SP
(1-
PO
RT)
PO
E
SP
POE
POE
(1-
PO
RT)
PO
E
SP
(1-
PO
RT)
PO
E
SP
POE
POE
CLIENT
VMS
AN
TE
NN
A
AN
TE
NN
A
SOFTWARE (SERVER)
RECORDER W/ VMS
NETWORK VIDEO
ENCLOSURE
NEMA
ENCLOSURE
NEMA
EXTENDER
POEPOE
EXTENDER
POE
CABLE
CONSOLE
KVM
MM
FO
PA
TC
H
CA
BL
E
MMFO CABLE
PATCH CABLE
MMFO
CABLE
ANTENNA
CABLE
ANTENNA
TELECOMMUNICATIONS ROOM
(RACK MOUNT)
POE SURGE PROTECTOR
(REMOTE CAMERA LOCATION)
(REMOTE CAMERA LOCATION)
A 1 OF 1
NTS
3602
TYPICAL NETWORK LINE DIAGRAM
VIDEO SURVEILLANCE SYSTEM (VSS)
LEGEND:
GENERAL NOTES:
ES3602
REVISE DRAWING NUMBER NDP
ONE (1) RJ45 PORT (ON NETWORK SWITCH) PER POE NETWORK CAMERA.3.
NO POE EXTENDER).
SHALL NOT EXCEED 656 FEET (200m) WITH ONE (1) POE EXTENDER (328 FEET (100m) WITH
TOTAL CAT-6 NETWORK CABLE LENGTH FROM NETWORK SWITCH TO POE NETWORK CAMERA 2.
ALL CABLING SHOWN IS CATEGORY 6 (CAT-6) NETWORK CABLE (UNLESS NOTED OTHERWISE).1.(200m), TYP.
UP TO 656 FT
(100m), TYP.
UP TO 328 FT
(IF APPLICABLE)
STORAGE
NETWORK ATTACHED
MULTIMODE FIBER OPTIC
SURGE PROTECTOR
FIBER OPTIC PATCH PANEL
KEYBOARD-VIDEO-MOUSE
VIDEO MANAGEMENT SYSTEM
POWER OVER ETHERNET
MMFO
SP
FOPP
KVM
VMS
POE
A. CARLOS
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:15:37 AM11/24/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\Revisions in progress\ES3603.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
06/30/15
ACA 09-28-15
HDR/A. CARLOS
OF VIEW
TRIANGLE INDICATES FIELD
FIELD OF VIEW
SEMI-CIRCLE INDICATES
PAN-TILT-ZOOM (PTZ) CAMERA
180 DEGREE CAMERA 360 DEGREE CAMERA
FIXED CAMERA
CIRCLE INDICATES FIELD OF VIEW
CIRCLE INDICATES FIELD OF VIEW
A 1 OF 1
NTS
3603
CAMERA FIELD OF VIEW DETAILS
VIDEO SURVEILLANCE SYSTEM (VSS)
ES3603
REVISE DRAWING NUMBER NDP
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:15:39 AM11/24/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\New Stds - in progress\ES3604-01.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY -
3604
NTS
1 OF 3
ES3604-01
BRACKET
CORNER MOUNTING
GANG BOX
WALL
BRACKET
WALL MOUNTING
POLE
BRACKET
POLE MOUNTING
STRAP. TYP.
STAINLESS STEEL
BRACKET
POLE MOUNTING
BRACKET
POLE MOUNTING
ROUND POLE
SQUARE POLE
WALL
GANG BOX
CEILING
NOTES:
(TYP.)
ASSEMBLY
CAMERA
(TYP.)
ASSEMBLY
CAMERA
MANUFACTURER'S INSTRUCTIONS AND CONTRACT DOCUMENTS.
ACCESSORIES; ALL IN ACCORDANCE WITH THE SCRRA ENGINEERING STANDARDS,
WITH ALL REQUIRED FITTINGS, BOXES, TERMINATIONS AND OTHER INSTALLATION
OTHERWISE). CONDUIT SHALL BE FURNISHED AND INSTALLED AS A SYSTEM
CABLING PATHWAY AND RACEWAY ELEMENTS NOT SHOWN (UNLESS SHOWN
FROM OUTDOOR ELEMENTS, IF APPLICABLE.
ALL SUPPORTING SYSTEM CABLING SHALL BE CONCEALED IN CONDUITS
AS REQUIRED BY MANUFACTURER.
CAMERA MOUNT, EQUIPMENT MOUNT AND MOUNTING SUPPORT HARDWARE
AND RACEWAY CONFIGURATION MAY VARY BY LOCATION.
AND MOUNTING CONFIGURATION MAY VARY BY LOCATION. CABLING PATHWAY
THIS DRAWING FOR REFERENCE ONLY. CAMERA TYPE, EQUIPMENT TYPE
4.
3.
2.
1.
TOP VIEWROUND POLE
TOP VIEWSQUARE POLESIDE VIEW
TOP VIEWTOP VIEW
CAMERACORNER MOUNTED
SIDE VIEW SIDE VIEW
WALL MOUNTED
CAMERA
WALL SURFACE MOUNTED
CAMERA
SIDE VIEW
CEILING SURFACE MOUNTED
CAMERA
CAMERAPOLE MOUNTED
GANG BOX
CONFIGURATIONS (TYPICAL)
EQUIPMENT MOUNTING
VIDEO SURVEILLANCE SYSTEM (VSS)
07-22-15
XXXXREVISIONXX-XX-XXX
L. AQUINO
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:15:39 AM11/24/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\New Stds - in progress\ES3604-02.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
POLE
STRAP. TYP.
STAINLESS STEELENCLOSURE
WEATHERPROOF
-
3604
NTS
2 OF 3
ES3604-02
TYP.
ASSEMBLY,
CAMERA
BASE
CEILING
WALL
TYP.
ASSEMBLY,
CAMERA
CEILING
ENCLOSURE
WEATHERPROOF
WALL
CEILING
BRACKET
PARAPET MOUNTING
BRACKET
MOUNTING
RECESSED
BRACKET
PENDANT MOUNTING
MOUNTED CONDUIT
EXPOSED SURFACE
MOUNTED CONDUIT
EXPOSED SURFACE
FLAT SURFACE
HORIZONTAL
NOTES:
2.
1.
AS REQUIRED BY MANUFACTURER.
CAMERA MOUNT, EQUIPMENT MOUNT AND MOUNTING SUPPORT HARDWARE
AND RACEWAY CONFIGURATION MAY VARY BY LOCATION.
AND MOUNTING CONFIGURATION MAY VARY BY LOCATION. CABLING PATHWAY
THIS DRAWING FOR REFERENCE ONLY. CAMERA TYPE, EQUIPMENT TYPE
4.
3.
MANUFACTURER'S INSTRUCTIONS AND CONTRACT DOCUMENTS.
ACCESSORIES; ALL IN ACCORDANCE WITH THE SCRRA ENGINEERING STANDARDS,
WITH ALL REQUIRED FITTINGS, BOXES, TERMINATIONS AND OTHER INSTALLATION
OTHERWISE). CONDUIT SHALL BE FURNISHED AND INSTALLED AS A SYSTEM
CABLING PATHWAY AND RACEWAY ELEMENTS NOT SHOWN (UNLESS SHOWN
FROM OUTDOOR ELEMENTS, IF APPLICABLE.
ALL SUPPORTING SYSTEM CABLING SHALL BE CONCEALED IN CONDUITS
CONFIGURATIONS (TYPICAL)
EQUIPMENT MOUNTING
VIDEO SURVEILLANCE SYSTEM (VSS)
PARAPET MOUNTED
CAMERA
SIDE VIEW EXPOSED CONDUIT
WALL SURFACE MOUNTED
CAMERA
SIDE VIEW
POLE MOUNTED
WEATHERPROOF ENCLOSURE
WALL MOUNTED
WEATHERPROOF ENCLOSURE
SIDE VIEW SIDE VIEW
CEILING FLUSH MOUNTED
CAMERA
EXPOSED CONDUIT
CEILING SURFACE MOUNTED
CAMERA
SIDE VIEW
SIDE VIEW
PENDANT MOUNTED
CAMERA
SIDE VIEW
07-22-15
XXXXREVISIONXX-XX-XXX
L. AQUINO
DIRECTOR OF ENGINEERING AND CONSTRUCTION
REVISION
STANDARD
SHEET
SCALE:
CADD FILE:
ENG.DES.DATEREV. DESCRIPTION
DRAWN BY: DATE:
FOR NON-SCRRA APPROVED USES:
ALL RIGHTS RESERVED.
ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA.
USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN
THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH
AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF
WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES
STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED
THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE
SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF
SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY.
UserName=> carlosa Date Plotted: 10:15:40 AM11/24/2015 Plot Driver=> S:\Plot Drivers\practice_pdf.plt FileName=> S:\V8EngStds\New Stds - in progress\ES3604-03.dgn
ASSISTANT DIRECTOR: STANDARDS & DESIGN
ENGINEERING STANDARDS
ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012
SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY
3604
NTS
3 OF 3-
ES3604-03
(RECTANGULAR BEAM)
CAMERA - CANOPY MOUNTED
GANG BOX
BEAM
SUPPORT
METAL
TYP.
ASSEMBLY,
CAMERA
HOLE
INCH•-
SEE NOTE 1
GANG BOX
CAMERA CABLING
SEE NOTE 1
BEAM
SUPPORT
METAL
MOUNTED CONDUIT
EXPOSED SURFACE
HOLE
INCH•-
CAMERA CABLING
GANG BOX
HOLE
INCH•-
SEE NOTE 1
BEAM
SUPPORT
METAL
BEAM
SUPPORT
METAL
GANG BOX
MOUNTED CONDUIT
EXPOSED SURFACE
HOLE
INCH•-
CABLING
CAMERA
SEE NOTE 1
(CHANNEL BEAM)
CAMERA - CANOPY MOUNTED
BEAM
SUPPORT
METAL
GANG BOX
MOUNTED CONDUIT
EXPOSED SURFACE
HOLE
INCH•-
CABLING
CAMERA
SEE NOTE 1
GANG BOX
BEAM
SUPPORT
METAL
HOLE
INCH•-
SEE NOTE 1
(I-BEAM)
CAMERA - CANOPY MOUNTED
NOTES:
5.
4.
3.
2.
1.
MANUFACTURER'S INSTRUCTIONS AND CONTRACT DOCUMENTS.
ACCESSORIES; ALL IN ACCORDANCE WITH THE SCRRA ENGINEERING STANDARDS,
WITH ALL REQUIRED FITTINGS, BOXES, TERMINATIONS AND OTHER INSTALLATION
OTHERWISE). CONDUIT SHALL BE FURNISHED AND INSTALLED AS A SYSTEM
CABLING PATHWAY AND RACEWAY ELEMENTS NOT SHOWN (UNLESS SHOWN
FROM OUTDOOR ELEMENTS, IF APPLICABLE.
ALL SUPPORTING SYSTEM CABLING SHALL BE CONCEALED IN CONDUITS
AS REQUIRED BY MANUFACTURER.
CAMERA MOUNT, EQUIPMENT MOUNT AND MOUNTING SUPPORT HARDWARE
AND RACEWAY CONFIGURATION MAY VARY BY LOCATION.
AND MOUNTING CONFIGURATION MAY VARY BY LOCATION. CABLING PATHWAY
THIS DRAWING FOR REFERENCE ONLY. CAMERA TYPE, EQUIPMENT TYPE
OR MOUNTING BRACKET DIMENSION (AT MOUNTING POINT).
STEEL PLATE WELDED TO JOIST AND SIZED SAME AS OUTSIDE CAMERA
07-22-15
XXXXREVISIONXX-XX-XXX
L. AQUINO
CONFIGURATIONS (TYPICAL)
EQUIPMENT MOUNTING
VIDEO SURVEILLANCE SYSTEM (VSS)
FRONT VIEW SIDE VIEW
FRONT VIEW SIDE VIEWFRONT VIEW SIDE VIEW