4
3
2
11
2
3
4
DCBA
CBA
1 8
DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION
DRAWING NUMBER
COMMSCOPE, INC.
010FAN-OUT BRACKET
(192 POS)1
009 #4-40 X .25 SCREW 8
008 #12 WASHER 3
007 #12-24 X .375 SCREW 3
006FAN-OUT BRACKET(ONLY 96 POS IFC)
1
005FAN-OUT BRACKET
(ALL IFC EXCEPT 96 POS)1
004 O-RING 1
003 CABLE CLAMP KIT 1
002 CABLE CLAMP BRACKET 1
001 IFC REAR TRAY, LEFT, UP 1
ITEM DESCRIPTION QTY
NGFB-ACCRCMSLU BLACK TEXTURED
NGF-ACCRCMSLU PUTTY WHITE
CATALOG FINISH
NOTES: 1 REMOVE EXISTING LEFT TRAY AND REPLACE WITH ITEM 001 AS SHOWN. 2 SEE SHEET 2. 3. PREPARE AND ROUTE CABLE ASSEMBLIES AS SHOWN IN USER MANUAL WITH NGF TERMINAL BLOCK. 4 SHOW 4 CABLE CLAMPS ONLY REFERENCE.
(3) (3)
REAR VIEWCABLE CLAMP ASSEMBLY
001 009 1
(4)
004 005 009
004 006 009
(2) (2)
OR
2
2
002 007 008
0034
999 ROUTING DRAWING 1
NGF-ACCRCMSLU-16 PUTTY WHITE
DATEDWNMCOREVC
24-FEB-15GCC40019926MCOB
04-AUG-16IAV40032679MCOC
SHT. OFDWN: HERMAN SAENZ
DO NOT SCALE DRAWING ENGR: JOSE MENDOZA
CREV300001771867
CSIZE
ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A
CONVERSION KIT,NGF-TB, 96/144,LEFT UP
TITLE© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONSARE THE PROPRIATARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THESPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.
004 010 009
(2)
2
4
3
2
11
2
3
4
DCBA
CBA
2 8
DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION
DRAWING NUMBER
COMMSCOPE, INC.
.90REF
.65REF
ITEM 005SCALE 2.000 ITEM 006
SCALE 2.000
1.17REF
SHT. OFDWN: J SANTANA LOPEZ
DO NOT SCALE DRAWING ENGR: DAN HERZOG
CREV300001771867
CSIZE
ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A
CONVERSION KIT,NGF-TB, 96/144,LEFT UP
TITLE© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONSARE THE PROPRIATARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THESPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.
ITEM 010SCALE 2.000
4
3
2
11
2
3
4
DCBA
CBA
3 8
DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION
DRAWING NUMBER
COMMSCOPE, INC.
CABLE ROUTINGSTEP 1
DETAIL A
FOR RIBBONFIBER
FOR STRANDEDFIBER
SEE DETAIL A
REFERENCE CABLE ROUTING
TIE SUBUNITS WITH LACING(REF)
CLAMP LOCATION SHOWNON ASSEMBLY DRAWING(CLAMP CABLE BEFORE ROUTING)
ROUTE FIBER AS SHOWN
SHT. OFDWN: M. HOLMBERG
DO NOT SCALE DRAWING ENGR: J. SOLHEID
CREV300001771867
CSIZE
ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A
CONVERSION KIT,NGF-TB, 96/144,LEFT UP
TITLE© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONSARE THE PROPRIATARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THESPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.
4
3
2
11
2
3
4
DCBA
CBA
4 8
DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION
DRAWING NUMBER
COMMSCOPE, INC.
ROW 1
ROW 2
ROW 3
ROW 4
ROW 5
ROW 6
ROW 7
ROW 8
ROW 9
ROW 10
ROW 11
ROW 12
* ROUTE ALL FIBERS AROUND SPOOL AND OUT THE SIDE AS SHOWN. (LEAVE SLACK LOOP LONG)
CABLE ROUTINGSTEP 2
SHT. OFDWN: M. HOLMBERG
DO NOT SCALE DRAWING ENGR: J. SOLHEID
CREV300001771867
CSIZE
ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A
CONVERSION KIT,NGF-TB, 96/144,LEFT UP
TITLE© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONSARE THE PROPRIATARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THESPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.
4
3
2
11
2
3
4
DCBA
CBA
5 8
DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION
DRAWING NUMBER
COMMSCOPE, INC.
CABLE ROUTINGSTEP 3
ROW 1
ROW 2
ROW 3
ROW 4
ROW 5
ROW 6
ROW 7
ROW 8
ROW 9
ROW 10
ROW 11
ROW 12
* START WITH ROW 1 SEE CONNECTION TABLE (F/N 986) FOR CORRECT FIBERS. ROUTE FIBERS AS SHOWN TO ROW 1
ADJUST SLACK LOOPAS REQUIRED TOROUTE FIBERS
SHT. OFDWN: M. HOLMBERG
DO NOT SCALE DRAWING ENGR: J. SOLHEID
CREV300001771867
CSIZE
ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A
CONVERSION KIT,NGF-TB, 96/144,LEFT UP
TITLE© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONSARE THE PROPRIATARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THESPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.
4
3
2
11
2
3
4
DCBA
CBA
6 8
DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION
DRAWING NUMBER
COMMSCOPE, INC.
CABLE ROUTINGSTEP 4
NOTES: * ROUTE ROW 2 AS SHOWN. CONTINUE WITH ROWS 3, 4, 5, 6, AND 7. SEE CONNECTION TABLE FOR CORRECT FIBERS.
ROW 1
ROW 2
ROW 3
ROW 4
ROW 5
ROW 6
ROW 7
ROW 8
ROW 9
ROW 10
ROW 11
ROW 12
ROWS 1-7 ROUTE TO THEINSIDE OF RADIUS LIMITER
SHT. OFDWN: M. HOLMBERG
DO NOT SCALE DRAWING ENGR: J. SOLHEID
CREV300001771867
CSIZE
ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A
CONVERSION KIT,NGF-TB, 96/144,LEFT UP
TITLE© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONSARE THE PROPRIATARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THESPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.
4
3
2
11
2
3
4
DCBA
CBA
7 8
DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION
DRAWING NUMBER
COMMSCOPE, INC.
NOTES: * ROUTE ROW 8 AS SHOWN CONTINUE WITH 9, 10, 11, AND 12. SEE CONNECTION TABLE FOR CORRECT FIBERS.
CABLE ROUTINGSTEP 5
ROW 1
ROW 2
ROW 3
ROW 4
ROW 5
ROW 6
ROW 7
ROW 8
ROW 9
ROW 10
ROW 11
ROW 12
ROWS 8-12 ROUTE TO THE OUTSIDE OF RADIUS LIMITER
SHT. OFDWN: M. HOLMBERG
DO NOT SCALE DRAWING ENGR: J. SOLHEID
CREV300001771867
CSIZE
ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A
CONVERSION KIT,NGF-TB, 96/144,LEFT UP
TITLE© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONSARE THE PROPRIATARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THESPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.
4
3
2
11
2
3
4
DCBA
CBA
8 8
DIMENSIONS IN INCHESTHIRD ANGLE PROJECTION
DRAWING NUMBER
COMMSCOPE, INC.
FINISHED CABLE ROUTING
NOTES: * AFTER INSTALLING CABLE, EXTEND ALL ADAPTER PACKS. ADJUST SLACK LOOP AS NECESSARY. * PUSH ADAPTER PACKS BACK IN, CHECK FIBER FOR BENDS. REDRESS FIBERS IF NECESSARY.
SHT. OFDWN: M. HOLMBERG
DO NOT SCALE DRAWING ENGR: J. SOLHEID
CREV300001771867
CSIZE
ALL DIMS AND TOLERANCES .XX:�#�N/AARE INCHES UNLESS .XXX:�#�N/AOTHERWISE SPECIFIED ANGULAR:�#�N/A
CONVERSION KIT,NGF-TB, 96/144,LEFT UP
TITLE© 2016 COMMSCOPE, INC.CONFIDENTIAL NOTICE: THESE DRAWINGS AND SPECIFICATIONSARE THE PROPRIATARY PROPERTY OF COMMSCOPE, INC.AND MAY BE USED ONLY FOR THESPECIFIC PURPOSE AUTHORIZED IN WRITING BY COMMSCOPE, INC.