7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
1/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved
www.huawei.com
Internal
OptiX OSN 1500250035007500
Ethernet Services Configuration
(Manual Configuration)
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
2/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 1
Upon completion of this course, you will be
able to:
Explain the menu of iManager T2000 forEthernet Services
Describe the process of configuring
Ethernet Services on the T2000
Learn how to configure Ethernet Services
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
3/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 2
Chapter 1 The Basic Concepts
Chapter 2 The EPL Service Configuration
Chapter 3 The EPLAN Service Configuration
Chapter 4 The EVPL Service Configuration
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
4/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 3
Tag flag is used to identify the type of packets. Three types of TAG flags
are available: tag aware, access, and hybrid.
Tag Aware: When the port is set to be tag aware, the port transmits
the packets with the Tag flag transparently and discards those
without the Tag flag
Access: When the port is set to be access, the port attaches a Tag
flag to the packets without Tag flag according to its VLAN ID and
discards those with the Tag flag.
Hybrid: When the port is set to be hybrid, the port can processpackets regardless of the Tag flag and attach a Tag flag to the
packets without the Tag flag according to its VLAN ID.
Tag flag:
Parameters for the Ethernet interface
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
5/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 4
Parameters for the Ethernet interface
Tag flag Untag flag
Tag aware (In) Transmit transparently discard
Tag aware (Out) Transmit transparently
Access (In) discard attach a Tag flag (default Vlan)
Access (Out) Delete the Tag flag (default Vlan)
Hybrid (In) Transmit transparently attach a Tag flag (default Vlan)
Hybrid (Out)If Vlan is the same, delete the Tag flag,
otherwise transmit transparently
PortPackets
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
6/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 5
Parameters for the Ethernet interface
VLAN ID:
VLAN ID of the port (MAC or VCTRUNK).
Working mode:
It can be set to auto-negotiation, 10 Mbit/s half/full-duplex,100 Mbit/s half/full-duplex or 1 Gbit/s full-duplex. The
Ethernet interfaces of the interconnected equipment shouldwork under the same fixed working mode; otherwise, thepacket may be lost and the rate may decrease, or theservice may be completely interrupted upon large volume oftraffic.
Port type:
There are two types: P and PE. Provider edge (PE) is themarginal port of the service provider. Provider (P) is thecore network port of the service provider. Port type isneeded when configuring EVPL and EVPLAN services.
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
7/88HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 6
Parameters for the Ethernet interface
LCAS enable:
Maximum packet length:
Whether to enable LCAS.
Set this item for the external port, 1522 bytes by default.
Mapping protocol:
It is preferable to select the default- GFP mapping protocol.
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
8/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 7
Reference: G.8010 /Y.1306 (G.ethna),
G.8011 (G.ethsrv),
G.8012.1 (G.eota.1).
Ethernet Services Types EPL: Ethernet Private Line Service.
EPLAN: Ethernet Private LAN Service .
EVPL: Ethernet Virtual Private Line Service.
EVPLAN: Ethernet Virtual Private LAN Service.
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
9/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 8
Chapter 1 The Basic Concepts
Chapter 2 The EPL Service Configuration
Chapter 3 The EPLAN Service Configuration
Chapter 4 The EVPL Service Configuration
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
10/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 9
For EPL Service, there are three types:
the Point-to-Point EPL Service
the MAC Shared EPL Service
the VCTRUNK Shared EPL Service
Configuring the EPL Service
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
11/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 10
Configuring the EPL Service
Configuring the Point-to-Point EPL Service:
Engineering Requirements
Engineering Planning
Configuration Process
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
12/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 11
Configuring the EPL Service
Configuring the Point-to-Point EPL Service:
User Service requirement Source station Sink station Bandwidth
A Point-to-point NE1 NE5 10 Mbit/s
B Point-to-point NE1 NE5 40 Mbit/s
STM-16two-fiberbidirectional MSP ring
T2000
STM-4two-fiber
bidirectional non-protection chain
NE1
NE2
NE3
NE4
NE5
Engineering Requirements
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
13/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 12
Configuring the EPL Service
Configuring the Point-to-Point EPL Service:
Engineering Planning
Step 1: Networking Diagram
Step 2: Board Information of Each NE
Step 3: Service Configuration Diagram of Each NE
Step 4: Timeslot Allocation Diagram
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
14/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 13
A B
STM-16 two-fiberbidirectional MSP ring
T2000
STM-4 two-fiberbidirectional non-protection chain
NE1
NE2
NE3
NE4
NE5
A B
VC-Trunk
MAC1 MAC2
MAC1 MAC2
Company A Service
Company B Service
Configuring the EPL Service
Step 1: Networking Diagram
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
15/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 14
Board layout of NE1
Configuring the EPL Service
Step 2: Board Information of Each NE
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
16/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 15
Board layout of NE5
Configuring the EPL Service
Step 2: Board Information of Each NE
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
17/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 16
VC4-4:VC12-1~VC12-5
MAC1
A10M
40M
B
VCTRUNKMAC
MAC2
VCTRUNK1
VCTRUNK2
VC-4-1:VC-3-1
SDHVC4-4:VC12-1~VC12-5
VCTRUNK
VCTRUNK1
VCTRUNK2
VC-4-1:VC-3-1
MAC1A
10M
40M
B
MAC
MAC2
NE1NE5
Service configuration diagram
Configuring the EPL Service
Step 3: Service Configuration Diagram of Each NE
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
18/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 17
Configuring the EPL Service
Service Attribute A B
Source NE NE1 NE1
Source board - port 13-N1EFS4-1 13-N1EFS4-2
Source timeslot VC4-4: VC12-1VC12-5 VC4-1: VC3-1
Source VCTRUNK VCTRUNK1 (Tag aware) VCTRUNK2 (Tag aware)
Working mode of source MAC port Auto negotiation Auto negotiation
TAG flag of source MAC port Access Access
VLAN ID of source MAC port 1 2
Bound bandwidth 5 x VC-12 1 x VC-3
Sink NE NE5 NE5
Sink board - port 15-N1EFS4-1 15-N1EFS4-2
Sink timeslot VC4-4: VC12-1VC12-5 VC4-1: VC3-1
Sink VCTRUNK VCTRUNK1 (Tag aware) VCTRUNK2 (Tag aware)
Working mode of sink MAC port Auto negotiation Auto negotiation
TAG flag of sink MAC port Access Access
VLAN ID of sink MAC port 1 2
Step 3: Service Configuration Diagram of Each NE
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
19/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 18
Configuring the EPL Service
Timeslot
NE2Station NE3 NE4NE1
12-SL16-1
NE1
7-SL16-112-SL16-1 7-SL16-112-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1
Forward
NE5NE4
13-SL4-1 7-SL4-1
Ring
Chain
Add/Drop
VC-4-313-EFS4: VC4-4
VC-12: 1-5
VC-4-413-EFS4: VC-4-1
VC-3: 1
VC-4-3
VC-4-4
15-EFS4: VC4-4
VC-12: 1-5
15-EFS4: VC-4-1
VC-3: 1
Station
Step 4: Timeslot Allocation Diagram
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
20/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 19
Configuring the EPL Service
Configuring the Point-to-Point EPL Service:
Configuration Process
Step 1: Creating a board
Step 2: Configuring Ethernet interfaces
Step 3: Configuring binding paths
Step 4: Creating the point-to-point EPL service
Step 5: Configuring committed access rate (CAR)
(Optional )
Step 6: Configuring the cross-connect from Ethernet
boards to SDH line boards
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
21/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 20
Configuring the EPL Service
Step 1: Creating a board
Right click
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
22/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 21
Configuring the EPL Service Step 2: Configuring Ethernet interfaces
Right click
Left click
Left click
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
23/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 22
Configuring the EPL Service Step 3: Configuring binding paths
Left click
Left click
Left click
Left click
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
24/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 23
Configuring the EPL Service
Step 4: Creating the point-to-point EPL service
Left clickLeft click
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
25/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 24
Configuring the EPL Service
Left click
Step 4: Configuring committed access rate (CAR) (Optional )
Left click
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
26/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 25
Configuring the EPL Service
Step 6: Configuring the cross-connect from Ethernet boards to SDH line boards
Left click Left clickLeft click
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
27/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 26
Summary
Creating an Ethernet board
Configuring Ethernet interfaces
External Port: Basic Attributes, Tag Attribute
Internal Port: Tag Attribute, LCAS
Configuring binding paths: Configurable Ports, Level, Direction, Available VC4, timeslots
Creating the MAC shared EPL service:
Service Type, Service Direction, Ports, VLAN, TAG, Port Type
Configuring committed access rate (CAR):
CAR ID, Capacity, Ports
Configuring the cross-connect from Ethernet boards to SDH line boards
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
28/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 27
Configuring the EPL Service
For EPL Service, there are three types:
the Point-to-Point EPL Service
the MAC Shared EPL Service
the VCTRUNK Shared EPL Service
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
29/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 28
Configuring the EPL Service
Configuring the MAC Shared EPL Service :
Engineering Requirements
Engineering Planning
Configuration Process
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
30/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 29
STM-16two-fiberbidirectional MSP ring
T2000
STM-4two-fiberbidirectional non-
protection chain
NE1
NE2
NE3
NE4
NE5
Engineering Requirements
Configuring the EPL Service
Configuring the MAC Shared EPL Service:
Source User Service requirement Source station Sink User Sink station Bandwidth
C MAC Shared NE1 C(1) NE5 10 Mbit/s
C MAC Shared NE1 C(2) NE5 10 Mbit/s
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
31/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 30
Configuring the EPL Service
Engineering Planning
Configuring the MAC Shared EPL Service :
Step 1: Networking Diagram Step 2: Board Information of Each NE
Step 3: Service Configuration Diagram of Each NE
Step 4: Timeslot Allocation Diagram
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
32/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 31
T2000NE1
NE2
NE3
NE4 NE5A B
A BVC-Trunk
MAC1 MAC2
MAC1 MAC2
MAC3 MAC4
C(2)C(1)
C (Headquarters)
MAC3
C & C(1) Service
C & C(2) Service
Configuring the EPL Service
Step 1: Networking Diagram
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
33/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 32
VC4-4:VC12-1~VC12-5
MAC1A
10M
40M
B
VCTRUNKMAC
MAC2
VCTRUNK1
VCTRUNK2
VC-4-1:VC-3-1SDH
VC4-4:VC12-1~VC12-5
VCTRUNK
VCTRUNK1
VCTRUNK2
VC-4-1:VC-3-1
MAC1A
10M
40MB
MAC
MAC2
NE1 NE5
VCTRUNK3
VCTRUNK4
MAC3C1
10M
10M
C2MAC4
VC4-4:VC12-6~VC12-10
VC4-4:VC12-11~VC12-15
VCTRUNK3
VCTRUNK4
VC4-4:VC12-6~VC12-10
VC4-4:VC12-11~VC12-15
MAC3C
Configuring the EPL Service
Step 3: Service Configuration Diagram of Each NE
Step 2: Board Information of Each NE
NE1 and NE5 do not require any new board.
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
34/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 33
Configuring the EPL Service
Step 3: Service Configuration Diagram of Each NE
Service Attribute C & C(1) C & C(2)
Source NE NE1
Source board - port 13-N1EFS4-3
Source timeslot VC4-4: VC12-6VC12-10 VC4-4: VC12-11VC12-15
Source VCTRUNK VCTRUNK3 (Tag aware) VCTRUNK4 (Tag aware)
Working mode of source MAC port Auto negotiation Auto negotiation
TAG flag of source MAC port Tag aware Tag aware
VLAN ID of source MAC port 3 4
Bound bandwidth 5 x VC-12 5 x VC-12
Sink NE NE5
Sink board - port 15-N1EFS4-3 15-N1EFS4-4
Sink timeslot VC4-4: VC12-6VC12-10 VC4-4: VC12-11VC12-15
Sink VCTRUNK VCTRUNK3 (Tag aware) VCTRUNK4 (Tag aware)
Working mode of sink MAC port Auto negotiation Auto negotiation
TAG flag of sink MAC port Access Access
VLAN ID of sink MAC port 3 4
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
35/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 34
Timeslot
NE2Station NE3 NE4NE1
12-SL16-1
NE1
7-SL16-112-SL16-17-SL16-112-SL16-17-SL16-112-SL16-1 7-SL16-1
Forwared
NE5StationNE4
13-SL4-1 7-SL4-1
Ring
Chain
Add/Drop
VC-4-3 13-EFS4: VC4-4
VC-12: 6-15
VC-4-315-EFS4: VC4-4
VC-12: 6-15
Configuring the EPL Service
Step 4: Timeslot Allocation Diagram
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
36/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 35
Notice: We dont need the first step because the Ethernet boards
Have already been created.
Configuring the EPL Service
Configuring the MAC Shared EPL Service:
Configuration Process
Step 1: Creating a board (None)
Step 2: Configuring Ethernet interfaces
Step 3: Configuring binding paths
Step 4: Creating the MAC shared EPL service
Step 5: Configuring committed access rate (CAR) (Optional
Step 6: Configuring the cross-connect from Ethernet
boards to SDH line boards
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
37/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 36
Configuring the EPL Service Step 2: Configuring Ethernet interfaces
Right click
Left click
Left click
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
38/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 37
Configuring the EPL Service
Left click
Left click
Left click
Left click
Step 3: Configuring binding paths
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
39/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 38
Left click
Configuring the EPL Service
Left click
Step 4: Creating the MAC shared EPL service
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
40/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 39
Notice: These two steps are the same as that of the
point-to-point EPL service, except that some
parameters are different.
Configuring the EPL Service
Step 5: Configuring committed access rate (CAR) (Optional
Step 6: Configuring the cross-connect from Ethernet boards to
SDH line boards
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
41/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 40
Summary
Creating an Ethernet board
Configuring Ethernet interfaces
External Port: Basic Attributes, Tag Attribute
Internal Port: Tag Attribute, LCAS
Configuring binding paths:
Configurable Ports, Level, Direction, Available VC4, timeslots
Creating the MAC shared EPL service:
Service Type, Service Direction, Ports, VLAN, TAG, Port Type
Configuring committed access rate (CAR):
CAR ID, Capacity, Ports
Configuring the cross-connect from Ethernet boards to SDH line boards
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
42/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 41
For EPL Service, there are three types:
the Point-to-Point EPL Service
the MAC Shared EPL Service
the VCTRUNK Shared EPL Service
Configuring the EPL Service
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
43/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 42
Configuring the EPL Service
Configuring the VCTRUNK Shared EPL Service :
Engineering Requirements
Engineering Planning
Configuration Process
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
44/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 43
STM-16 two-fiberbidirectional MSP ring
T2000
STM-4 two-fiber
bidirectional non- protection chainNE1
NE2
NE3
NE4
NE5
Engineering Requirements
Configuring the EPL Service
Configuring the VCTRUNK Shared EPL Service:
Source
User
Service
requirement
Source
station
Sink User Sink
station
Bandwidth
D VCTRUNK Shared NE2 D NE3 300 Mbit/s
E VCTRUNK Shared NE2 E NE3 300 Mbit/s
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
45/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 44
Configuring the EPL Service
Configuring the VCTRUNK Shared EPL Service :
Engineering Planning
Step 1: Networking Diagram
Step 2: Board Information of Each NE
Step 3: Service Configuration Diagram of Each NE
Step 4: Timeslot Allocation Diagram
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
46/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 45
T2000
NE1
NE2
NE3
NE4
NE5
D
B
VC-Trunk
MAC1
MAC2
MAC2MAC1
E
D E D & D Service
E & E Service
Configuring the EPL Service
Step 1: Networking Diagram
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
47/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 46
Configuring the EPL Service
Step 2: Board Information of Each NEBoard layout of NE2 and NE3
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
48/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 47
MAC1D300M
E
VCTRUNKMAC
MAC2
SDH
VC4-1:VC3-1~VC3-3
VC4-2:VC3-1~VC3-3
VCTRUNK
VCTRUNK1
MAC1 D
E
MAC
MAC2
NE2 NE3
300M
300M
300MVC4-1:VC3-1~VC3-3
VC4-2:VC3-1~VC3-3
VCTRUNK1
Configuring the EPL Service
Step 3: Service Configuration Diagram of Each NE
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
49/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 48
Configuring the EPL Service
Step 3: Service Configuration Diagram of Each NE
Service Attribute D E
Source NE NE2
Source board - port 13-N1EGS2-1 13-N1EGS2-2
Source timeslot VC4-1: VC3-1VC3-3, VC4-2: VC3-1VC3-3
Source VCTRUNK VCTRUNK1 (Tag aware)
Working mode of source MAC port 1000M full duplex 1000M full duplex
TAG flag of source MAC port Access Access
VLAN ID of source MAC port 1 2
Bound bandwidth 6 x VC-3
Sink NE NE3
Sink board - port 13-N1EGS2-1 13-N1EGS2-2
Sink timeslot VC4-1: VC3-1VC3-3, VC4-2: VC3-1VC3-3
Sink VCTRUNK VCTRUNK1 (Tag aware)
Working mode of sink MAC port 1000M full duplex 1000M full duplex
TAG flag of sink MAC port Access Access
VLAN ID of sink MAC port 1 2
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
50/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 49
Timeslot
NE2Station NE3 NE4NE1
12-SL16-1
NE1
7-SL16-112-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1
Forward
Ring
Add/Drop
VC-4-313-EGS2: VC4-1
VC-3: 1-3
VC-4-413-EGS2: VC4-2
VC-3: 1-3
Configuring the EPL Service
Step 4: Timeslot Allocation Diagram
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
51/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 50
Notice: The steps are the same as the MAC shared EPL Service.
So here we dont need introduce them again.
Configuring the EPL Service
Configuring the VCTRUNK Shared EPL Service:Configuration Process
Step 1:Creating a board
Step 2: Configuring Ethernet interfaces
Step 3: Configuring binding paths
Step 4: Creating the VCTRUNK shared EPL service
Step 5: Configuring committed access rate (CAR) (Optional )
Step 6: Configuring the cross-connect from Ethernet boards to
SDH line boards
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
52/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 51
Summary
Creating an Ethernet board
Configuring Ethernet interfaces
External Port: Basic Attributes, Tag Attribute
Internal Port: Tag Attribute, LCAS
Configuring binding paths:
Configurable Ports, Level, Direction, Available VC4, timeslots Creating the VCTRUNK shared EPL service:
Service Type, Service Direction, Ports, VLAN, TAG, Port Type
Configuring committed access rate (CAR):
CAR ID, Capacity, Ports
Configuring the cross-connect from Ethernet boards to SDH line
boards
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
53/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 52
Chapter 1 The Basic Concepts
Chapter 2 The EPL Service Configuration
Chapter 3 The EPLAN Service Configuration
Chapter 4 The EVPL Service Configuration
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
54/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 53
Configuring the EPLAN Service
Configuring the EPLAN Service:
Engineering Requirements
Engineering Planning
Configuration Process
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
55/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 54
STM-16two-fiberbidirectional MSP ring
T2000STM-4 two-fiber
bidirectional non- protection chainNE1
NE2
NE3
NE4NE5
Configuring the EPLAN Service
Engineering Requirements
Source User Service requirement Source station Sink User Sink station Bandwidth
F(1) EPLAN NE2 F(2) NE3 10 Mbit/s
F(3) EPLAN NE4 F(2) NE3 10 Mbit/s
F(1) EPLAN NE2 F(3) NE4 10 Mbit/s
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
56/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 55
Configuring the EPLAN Service
Engineering Planning
Step 1: Networking Diagram
Step 2: Board Information of Each NE
Step 3: Service Configuration Diagram of Each NE
Step 4: Timeslot Allocation Diagram
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
57/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 56
T2000
NE1
NE2
NE3
NE4
NE5
B
VC-Trunk
MAC1
MAC1
F(1)
F(2)
MAC1
F(3)
VB
MAC1
VCTRUNK1
MAC1
VCTRUNK2VCTRUNK1 VB
VB
MAC1
VCTRUNK1
F(1) & F(2) Service
F(3) & F(2) Service
F(1) & F(3) Service
Configuring the EPLAN Service
Step 1: Networking Diagram
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
58/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 57
Board layout of NE2 and NE3
Configuring the EPLAN Service
Step 2: Board Information of Each NE
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
59/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 58
Configuring the EPLAN Service
Step 2: Board Information of Each NEBoard layout of NE4
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
60/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 59
Service configuration diagram
MAC1F2
10M
VCTRUNKMAC
SDH
VC4-4:VC12-1~VC12-5
VCTRUNK
VCTRUNK1
MAC1F1
MAC
NE3
NE2
10M
VC4-4:VC12-1~VC12-5VCTRUNK1
VB1
LP1 LP2
LP3
VCTRUNK2VC4-4:VC12-6~VC12-10
VB1
VC4-4:VC12-1~VC12-5
VCTRUNK
VCTRUNK1
MAC1F3
MAC
NE4
10M
VB1
LP1
LP1
LP2
LP2
Configuring the EPLAN Service
Step 3: Service Configuration Diagram of Each NE
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
61/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 60
Configuring the EPLAN Service
Attribute \ Service F
Source NE NE3
Source board port 14-N1EFS0-1
Source timeslot VC4-4: VC12-1VC12-5 VC4-4: VC12-6VC12-10
Source VCTRUNK VCTRUNK1 (Tag Aware) VCTRUNK2 (Tag Aware)
Source VCTRUNK attribute PE PE
Working mode of source MAC port Auto negotiation
TAG flag of source MAC port Access
VLAN ID of source MAC port 11
VB VB1
Attached port MAC1, VCTRUNK1, VCTRUNK2
Sink NE NE2 NE4
Sink board port 14-N1EFS0-1 15-N1EFS0-1
Sink timeslot VC4-4: VC12-1VC12-5 VC4-4: VC12-1VC12-5
Sink VCTRUNK VCTRUNK1 (Tag Aware) VCTRUNK1 (Tag Aware)
Sink VCTRUNK attribute PE PE
Working mode of sink MAC port Auto negotiation Auto negotiation
TAG flag of sink MAC port Access Access
VLAN ID of sink MAC port 11 11
Virtual bridge (VB) VB1 VB1
Attached port MAC1, VCTRUNK1 MAC1, VCTRUNK1
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
62/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 61
Configuring the EPLAN Service
Step 3: Service Configuration Diagram of Each NE
Step 4: Timeslot Allocation Diagram
NE name VB VLAN ID Forwarding port
NE2 VB1 11 LP1, LP2
NE3 VB1 11 LP1, LP2, LP3
NE4 VB1 11 LP1, LP2
Timeslot
NE2Station NE3 NE4NE1
12-SL16-1
NE1
7-SL16-112-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1
Forward
Ring
Add/Drop
VC-4-5 14-EFS0: VC4-4
VC-12: 1-5
15-EFS0: VC4-4
VC-12: 1-5
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
63/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 62
Configuring the EPLAN Service
Configuration Process
Step 1: Creating a board
Step 2: Configuring Ethernet interfaces
Step 3: Configuring binding paths
Step 4: Creating the EPLAN service
Step 5: Configuring the forwarding filter table
Step 6: Configuring committed access rate (CAR) (Optional )
Step 7: Configuring the cross-connect from Ethernet boards to
SDH line boards
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
64/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 63
Configuring the EPLAN Service
Step 1: Creating a board
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
65/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 64
Configuring the EPLAN Service Step 2: Configuring Ethernet interfaces
Right click
Left click
Left click
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
66/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 65
Left click
Configuring the EPLAN Service
Left click
Left click
Left click
Step 3:
Configuring
binding paths
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
67/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 66
Left click
Configuring the EPLAN Service Step 4: Creating the EPLAN service
Left click
Left click
Left click
Left click
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
68/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 67
Configuring the EPLAN Service Step 5: Configuring the forwarding filter table
Left click
Left click
Left click
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
69/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 68
Configuring the EPLAN Service Step 6: Configuring committed access rate (CAR) (Optional )
Left click
Left click
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
70/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 69
Configuring the EPLAN Service Step 7: Configuring the cross-connect from Ethernet boards to SDH line
boards
Left click
Left clickLeft click
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
71/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 70
Summary
Creating an Ethernet board
Configuring Ethernet interfaces
External Port: Basic Attributes, Tag Attribute, VLAN
Internal Port: Tag Attribute, VLAN, LCAS
Configuring binding paths:
Configurable Ports, Level, Direction, Available VC4, timeslots Creating the EPLAN service:
VB Port, Mount Port, Port Type, Binding Path
Configuring the forwarding filter table
VB Port, VLAN ID, forwarding port
Configuring committed access rate (CAR):
CAR ID, Capacity, Ports
Configuring the cross-connect from Ethernet boards to SDH line boards
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
72/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 71
Chapter 1 The Basic Concepts
Chapter 2 The EPL Service Configuration
Chapter 3 The EPLAN Service Configuration
Chapter 4 The EVPL Service Configuration
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
73/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 72
Configuring the EVPL Service
Configuring the EVPL Service:
Engineering Requirements
Engineering Planning
Configuration Process
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
74/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 73
STM-16 two-fiberbidirectional MSP ring
T2000 STM-4 two-fiber
bidirectional non-protection chainNE1
NE2
NE3
NE4NE5
Configuring the EVPL Service
Engineering Requirements
Source
User
Service
requirement
Source
stationSink User
Sink
stationBandwidth
D EVPL NE2 D NE3 100 Mbit/s
E EVPL NE2 E NE3 100 Mbit/s
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
75/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 74
Configuring the EVPL Service
Engineering Planning
Step 1: Networking Diagram
Step 2: Board Information of Each NE
Step 3: Service Configuration Diagram of Each NE
Step 4: Timeslot Allocation Diagram
Configuring the EVPL Service
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
76/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 75
T2000
NE1
NE2
NE3
NE4
NE5
D
B
VC-Trunk
MAC1
MAC2
MAC2MAC1
E
D ED & D Service
E & E Service
g g
Step 1: Networking Diagram
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
77/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 76
Configuring the EVPL Service Step 2: Board Information of Each NE
Board layout of NE2 and NE3
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
78/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 77
Configuring the EVPL Service
Step 3: Service Configuration Diagram of Each NE
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
79/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 78
Configuring the EVPL Service
Step 3: Service Configuration Diagram of Each NE
Attribute \ Service D ESource NE NE2
Source board - port 14-N1EFS0-1 14-N1EFS0-2
Source timeslot VC4-4: VC12-1VC12-48
Source VCTRUNK VCTRUNK1 (Tag Aware )
Source VCTRUNK attribute PWorking mode of source MAC port 100M full duplex 100M full duplex
TAG flag of source MAC port Tag Aware Tag Aware
VLAN ID of source MAC port 11 11
Source MAC attribute PE PE
Bound bandwidth 48 x VC-12
Sink NE NE3
Sink board - port 14-N1EFS0-1 14-N1EFS0-2
Sink timeslot VC4-4: VC12-1VC12-48
Sink VCTRUNK VCTRUNK1 (Tag Aware )Sink VCTRUNK attribute P
Working mode of sink MAC port 100M full duplex 100M full duplex
TAG flag of sink MAC port Tag Aware Tag Aware
VLAN ID of sink MAC port 11 11
Sink MAC attribute PE PE
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
80/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 79
Configuring the EVPL Service
Step 3: Service Configuration Diagram of Each NE
Step 4: Timeslot Allocation Diagram
NE nameVCTRUNK-MAC
(path)
multi-protocol label switching (MPLS)
Tunnel VC
NE2 \ NE3 VCTRUNK1-MAC1 55 25
NE2 \ NE3 VCTRUNK1-MAC2 66 26
Station
Timeslot
NE1 NE2 NE3 NE4 NE1
12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1 12-SL16-1 7-SL16-1
VC4-4
VC12: 1-48
14EFS0: VC4-4
Forward
Add/Drop
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
81/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 80
Configuring the EVPL Service
Configuration Process
Step 1: Creating a board
Step 2: Configuring Ethernet interfaces
Step 3: Configuring binding paths
Step 4: Creating the EVPL service
Step 5: Configuring committed access rate (CAR)
(Optional )
Step 6: Configuring the cross-connect from Ethernet
boards to SDH line boards
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
82/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 81
Configuring the EVPL Service
Step 1: Creating a board
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
83/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 82
Configuring the EVPL Service Step 2: Configuring Ethernet interfaces
Right click
Left click
Left click
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
84/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 83
Configuring the EVPL Service Step 3: Configuring binding paths
Left click
Left click
Left click
Left click
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
85/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 84
Configuring the EVPL Service
Step 4: Creating the
EVPL service
Left clickLeft click Left click
Configuring the EVPL Service
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
86/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 85
Notice: These two steps are the same as that of the EPL service,
except that some parameters are different.
Configuring the EVPL Service
Step 5: Configuring committed access rate (CAR)
(Optional )
Step 6: Configuring the cross-connect from Ethernet
boards to SDH line boards
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
87/88
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 86
Summary
Creating an Ethernet board
Configuring Ethernet interfaces
External Port: Basic Attributes, Tag Attribute, VLAN
Internal Port: Tag Attribute, VLAN, LCAS, MPLS
Configuring binding paths:
Configurable Ports, Level, Direction, Available VC4, timeslots
Creating the EVPL service:
Service Type, Service Direction, Ports, TAG, VLAN, Tunnel, VC,
Port Type, Encapsulation Format
Configuring committed access rate (CAR):
CAR ID, Capacity, Ports
Configuring the cross-connect from Ethernet boards to SDH line
boards
-
7/30/2019 19-OTA105204 OptiX OSN Ethernet Services Configuration(Manual Configuration) ISSUE 1.21
88/88
www.huawei.com
Thank You