CutterOrthodontic PliersWire CutterLigature InstrumentBonding InstrumentOrthodontic ArticulatorMeasuring DeviceTorchLocking Tweezers / Chin CapImpression Tray
169172175178180181183185186187
165
Code No. Description Tooth
1 Case kit
27880 STR-018-3-3
27881 STR-018-3-3H ※
27884 STR-018-5-5
27885 STR-018-5-5H ※
Code No. Description Tooth
1 Case kit
27882 STR-022-3-3
27883 STR-022-3-3H ※
27886 STR-022-5-5
27887 STR-022-5-5H ※
-Wire Selection for .018" slot.-
-Wire Selection for .022" slot.-
[.018" x .025" Slots]Low frictionRound wire .012" / .014" / .016" / .018"Rect. wire .016" x .016"
Torque controlRect. wire .016" x .022"
.017" x .025"
.018" x .025"
[.022" x .028" Slots]Low frictionRound wire .012" / .014" / .016" / .018" / .020"Rect. wire .016" x .022"
Torque controlRect. wire .017" x .025"
.018" x .025"
.019" x .025"
.021" x .025"
.022" x .028"
.023"
Only UL3 : With the hook.※
Only UL3 : With the hook.※
27800 STR-U1R-018
STR-U1L-018
27802 STR-U2R-018
27803 STR-U2L-018
27804 STR-U3R-018
27805 STR-U3L-018
27806 STR-U3R-018H
27807 STR-U3L-018H
27808 STR-U45-018
27811 STR-L12-018 -
27813 STR-L3R-018
27814 STR-L3L-018
27815 STR-L3R-018H
27816 STR-L3L-018H
27817 STR-L4-018
27820 STR-L5-018
No. Description Tooth ColorMarking Torq. Ang.
Upper(10 ea.)
27840 STR-U1R-022 12 5
27841 STR-U1L-022 12 5
27842 STR-U2R-022 8 9
27843 STR-U2L-022 8 9
27844 STR-U3R-022 -2 11
27845 STR-U3L-022 -2 11
27846 STR-U3R-022H -2 11
27847 STR-U3L-022H -2 11
27848 STR-U45-022 -7 0
Lower(10 ea.)
27851 STR-L12-022 - 0 0
27853 STR-L3R-022 -11 7
27854 STR-L3L-022 -11 7
27855 STR-L3R-022H -11 7
27856 STR-L3L-022H -11 7
27857 STR-L4-022 -17 0
27860 STR-L5-022 -22 0
169
-Straight .022" slot-
171170
Pin & Ligature Cutter*Cut excess ligature wire. *Hard material inserts ensure cutting of ligature wire and elastic.*Joint part has changed from 3pc(YS) to 2pc(EVER Fine). This change can reduce the problem of rust in joint part.
605 with Hard Material
No.27605*Cut up to .012” (ø0.30mm)
*To avoid breakage, insert hard material on the tip.
*Fine curved shape provide per formance to cutligature wire on crowded area, dislocated area easily.
10°
*10° angle and fine curve allow easy to access bothpre molars and molars.
606S T/CNo.27606
606L T/CNo.27607
*Cut up to ●Round wire .012"-.026" ■Rect. wire .016"x.016"-.022"x.028"
*Cut up to ●Round wire .012"-.026" ■Rect. wire .016"x.016"-.022"x.028"
Company AYDM (EVER Fine 606L)
Size / 124mm Size / 147mm
*With long handle and small head to ensure easy access inhard to reach areas.
Distal End Cutter*Cut and hold distal end of arch wire.*Cemented carbide inserts provide high performance and long life of the tips.*Joint part has changed from 3pc(YS) to 2pc(EVER Fine). This change can reduce the problem of rust in joint part.
173172
419 Nance Closing Loop
No.27419
423Kim T/C (with Cutter)
No.27423*Maximum wire capacity .022”* W i t h us ing eac h s tep (3.5mm, 4.5mm, 5.5mm, 6.5mm), arrange the loop wire, apply torque on MEAW loop.
*Maximum wire capacity .016"x.022”*Cut up to .020” *Bend MEAW loop.
414 Young
No.27414
415 Tweed Arch
No.27415
416Tweed Loop Forming
No.27416
417 Three Jaw
No.27417
418 Bird Beak
No.27418
-Bending Pliers-
*Maximum wire capacity .022"x.028"*Hold arch wire, apply torq, offset-bend, inset-bend.
*Maximum wire capacity .036”*Quad Helix, lingual arch, activate of main wire.
*Maximum wire capacity .036”*Bend retainer wire, clasp.
*Maximum wire capacity .040”*Bend retainer wire, adjust inner bow w i th three s teps. (1.4mm, 3.0mm, 4.5mm in diameter)
*Maximum wire capacity .022"x.028”*Round beak is shaped 3 layers of cylinders (1.25mm, 1.85mm, 2.26mm in diameter) can be used for closing helical loop, helical loop, omega loop.
-Utility Pliers-
422 Utility
No.27422
421 WeingartNo.27421
*Insert, remove the main wire.*Bend ligature wire, UA.
*Insert, remove the main wire.*Multi purposes for tying ligature etc.
3mm
420How
No.27420
*Insert, remove the main wire.*Multi purposes for tying ligature etc.
Orthodontic Pliers
424Light Wire T/C (with Cutter)
No.27424*Maximum wire capacity .020”*Cut up to .020” *Designed for circle hook, tear drop.
-Bending Pliers-
-Crimping Pliers-
-Banding Pliers-
413Bracket Removing T/C
No.27413
-Debonding Pliers-
425 CrimpingNo.27425
411Band Margin
No.27411
412Band Removing
No.27412
3.5m
m
410Band Contouring
No.27410
*Traditional and classical design fascinate artistic mind. *Matte surface can avoid reflection of pliers under bright light.
175174
*With fine tips to ensure to insert into lingual or narrow part,crowded teeth.*With long handle to ensure to insert into lingual or narrow part,crowded teeth.*Matte surface can avoid reflection of pliers under bright light.*Supple curved handle fits female dentists.
*Texture of tip is 0.25mm(.010"), can hold arch wire firmly.
*Texture of tip is 0.25mm(.010"), can hold arch wire firmly.
440 Utility
No.27440
441 WeingartNo.27441
442 How
No.27442
Orthodontic Pliers
443Band Removing
No.27443
444Bracket Removing T/C
No.27444
177176
YS-603 StandardNo.22603
*Cut up to .048” (ø1.20mm)
YS-601No.22601
*Cut up to .032” (ø0.80mm)
YS-602KI
No.22602
*Cut up to .045” (ø1.10mm)
*Cut retainer wire, clasp wire.
No.27934
1) Insert the blade edge parallel to cap from mesial side of buccal tube slot.
2) By gripping the handle, Move the blade to distal side and remove the cap easily.
[Sectional Drawing]
[Sectional Drawing]
Blade
Buccal Tube
Cap
*Please remove the fallen cap from a mouth.
BladedeadBlaBBB ade
Buccal Tube
Cap
Blade
Wire Cutter
Convertible Cap Removing Pliers
Adams Pliers
Universal T/CNo.22001
No.27709
179178
*Steiner Type. *Coon Type.
*Tie ligature wire on the bracket.
*Used for applying both long and short type ligature wire.
*Tuck excess ligature wire.
*Tuck excess ligature wire.
*Tie ligature wire on the bracket with wing shape.*With one instrument, two function-tucking and tying.
YS-506No.22506
YS-507No.22507
YS-508No.22508
YS-704 Single End
No.22704
YS-704B Double End
No.22755
YS-704A TwisterNo.22754
Tying Pliers
Ligature Director
Cvd. No.22510
*For Lingual
*Put module on the bracket. *With ultra thin tips, easy to insert into the mouth.
*With groove, module can move easily and give power on bracket fairly.
Mosquito Str.No.22513
Str.No.22509
with Groove Str.No.22511
Module Pliers
Mosquito Cvd.No.22514
Arch Wire Director
Bracket Tweezer
No.22761
Bracket TweezerTying Pliers
YS-703No.22703
YS-701 No.22753
Bracket Tweezer
YS-551 No.22551
-for Construction Bite-
181180
*Before applying band, used for placement of separating elastic.
*Set band by patient's own occlusal force.*Tip can be replaced.
*Insert band.
*Hold firmly the bracket by groove at the tips.*At the end of the handle with measure (3.5mm, 4.0mm, 4.5mm, 5.0mm) helps bracket height and angulation.
*Remove surplus bonding material smoothly.
#1No.13205
#2 for Posterior No.13206
Separator Bracket Tweezers
Band Pusher
Band Seater
Surplus Cement Remover
YS-714No.22714
Articulator
No.22834(Parts 28 teeth)
YS-34 with ChartNo.22934
183182
*Education tool to learn the appropriate orthodontic force and result of the teeth position.*Also used for practice of placing the brackets and ligatures.*Metal tooth root for quick heat conduction.
YS-802ANo.22822
-Example of Practicing with the Typodont Practice Model-
1) A t t ac h t h e O RT va r i o u s Wax Form to the Typodont Ocluder by applying molten wax with an instrument.
2) Remove the jaws with the black base as pictured.
3) Dip the jaws into 55-60°C warm water.
4) Lift the jaws from the warm water and dip into cool water. Observe the result.
Image
*Wax form does not include.
*Wax form does not include.
Typodont Articulator
Typodont Teeth
Model Measuring DeviceMain body, Chart (25 sheets)Contents
*This measuring device is for the purpose of measuring following length/ Width below on a tooth model, constituting T shape ruler and (vertical, horizontal) indicator needle. The indicator needle designed to slide on its vertical surface.
*This measuring device is designed to measure following (1),(2),(3). For the measurement of (4) please use separately sold Orthodontic Caliper as the direction mentioned below. (1) Length of dental arch (2) Width of dental arch(3) Length of BASAL ARCH(4) Width of BASAL ARCH
[Direction of how to use]
A.Horizontal partB.Vertical partC.Indicator needle
Standard deviation table for width of dental crown, dental arch, BASAL ARCH is also available.
1) Width of dental arch With horizontal part A measure its distance between buccal sides of first premolar tooth.
2) Length of dental arch Fitting in its base line of horizontal part A to the point of first molar teeth in distal part. Then measure the distance to incisal edge of a central incisor with vertical part B.
3) Length of BASAL ARCH Setting horizontal part A as above picture indicates, slide the indicator needle C to fit in the bottom point of the root of a central incisor tooth.
4) Width of BASAL ARCH Measure the bottom point of the root of first premolar tooth with Orthodontic Calipers.
A
CB
YS-31 5NNo.22955
YS-31D Dial (5N)No.22930
YS-33 15cmNo.22933
OrthoNo.27907
*Weight / 245g (with the screen board)*Gas Volume / 15g*Combustion Time / 80min.*Flame Temperature / 1300°C (blue flame)
Size / W76.6xD54.5xH154mm
*1N ≒ 100g
YS-39No.22939
185184
Measure the force of coil spring and elastic.
*The head is given 70° angle to avoid direct dripping of wax on the nozzle when used lying down on the table.
70°
*Sharp flame is suitable for delicate work.*Gas is empty at the time of delivery.
Red needle remains to show the tension o f c o i l s p r i n g o r elastic.
Red needle moved pushing by black needle.
Tension Gauge
Orthodontic Calipers
Handy Torch
Specifications
Name of parts
B
A
Body
Gas refill opening
GAS flow control
Plunger (OFF-ON)
Nozzle coverNozzle
Screen plate
Air control Screw for Screen
*Check position of bracket on tooth.*Measure bracket height 4.5mm, 4.0mm and 3.5mm.
Boone Gauge
No.22868Maxillary Traction
No.22869
YS-707S No.22707
YS-708LNo.22708
Size / W210xD130mm
YS-706 No.22706
187186
YS-40No.22940
Locking Tweezers
Chin Cap
Tracing Plate
*Color coded for easy identification.*By an edge with height, the impression of a frenum or buccal mucous membrane can be taken firmly.*Easily bendable for a custom fit.*Impression materials stick to alminium well because of features of alminium itself,also they are difficult to be removed when in fitting.
No. DescriptionSize (mm)
a b c d
19111 Pink 62 44 15 20
19112 Blue 70 48 15 20
19113 Red 75 50 15 20
19114 Gold 82 53 17 22
19115 Violet 88 55 17 22
a
b
a
b
No. DescriptionSize (mm)
a b c d
19101 Pink 57 48 12 20
19102 Blue 62 54 12 20
19103 Red 68 60 12 22
19104 Gold 75 65 12 22
19105 Violet 84 70 13 22
Pink Blue Red
Gold Violet
Pink Blue Red
Gold Violet
Color Tray
*Aluminium
c d
cd
-Premium-
Lower
Upper
Scraper