1. LOW COST 2. SIMPLE 3. EFFICIENT
![Page 2: 1. LOW COST 2. SIMPLE 3. EFFICIENT](https://reader036.vdocuments.site/reader036/viewer/2022062501/568165f8550346895dd92349/html5/thumbnails/2.jpg)
EER
• Energy Efficiency Ratio =
Cooling Capacity in Btu / Hr
Power Consumption in Watts
![Page 3: 1. LOW COST 2. SIMPLE 3. EFFICIENT](https://reader036.vdocuments.site/reader036/viewer/2022062501/568165f8550346895dd92349/html5/thumbnails/3.jpg)
Mechanical Subcooling• Moving cooling
load from the main compressor to the subcooling compressor increases efficiency.
![Page 4: 1. LOW COST 2. SIMPLE 3. EFFICIENT](https://reader036.vdocuments.site/reader036/viewer/2022062501/568165f8550346895dd92349/html5/thumbnails/4.jpg)
R410A - A New Opportunity
• R410A = compressor EERs of 14 to16
• Not a refrigerant for medium or low temperature refrigeration.
• Line sizes must stay small due to high pressures, which points toward a one on one design.
![Page 5: 1. LOW COST 2. SIMPLE 3. EFFICIENT](https://reader036.vdocuments.site/reader036/viewer/2022062501/568165f8550346895dd92349/html5/thumbnails/5.jpg)
R410A Subcooling Medium Temp
• R410A EER = 16.0
• R404A EER = 7.1
• Transferred
BTUs
• 200% Efficiency
Gain
Big Compressor
Small Comp
![Page 6: 1. LOW COST 2. SIMPLE 3. EFFICIENT](https://reader036.vdocuments.site/reader036/viewer/2022062501/568165f8550346895dd92349/html5/thumbnails/6.jpg)
R410A Subcooling Low Temp
• R410A EER = 16.0
• R404A EER = 3.7
• Transferred
BTUs
• 400% Efficiency
Gain
Big Compressor
Small Comp
![Page 7: 1. LOW COST 2. SIMPLE 3. EFFICIENT](https://reader036.vdocuments.site/reader036/viewer/2022062501/568165f8550346895dd92349/html5/thumbnails/7.jpg)
R410A
R404A
![Page 8: 1. LOW COST 2. SIMPLE 3. EFFICIENT](https://reader036.vdocuments.site/reader036/viewer/2022062501/568165f8550346895dd92349/html5/thumbnails/8.jpg)
The ETL Tests
ETL is the established authority on refrigeration performance testing.
Medium Temp
![Page 9: 1. LOW COST 2. SIMPLE 3. EFFICIENT](https://reader036.vdocuments.site/reader036/viewer/2022062501/568165f8550346895dd92349/html5/thumbnails/9.jpg)
The ETL Tests
ETL is the established authority on refrigeration performance testing.
Low Temp
![Page 10: 1. LOW COST 2. SIMPLE 3. EFFICIENT](https://reader036.vdocuments.site/reader036/viewer/2022062501/568165f8550346895dd92349/html5/thumbnails/10.jpg)
The ETL Report
Download
From
BMIL.COM
![Page 11: 1. LOW COST 2. SIMPLE 3. EFFICIENT](https://reader036.vdocuments.site/reader036/viewer/2022062501/568165f8550346895dd92349/html5/thumbnails/11.jpg)
Distributed
Systems
Smaller Refrigera
nt Charge
![Page 12: 1. LOW COST 2. SIMPLE 3. EFFICIENT](https://reader036.vdocuments.site/reader036/viewer/2022062501/568165f8550346895dd92349/html5/thumbnails/12.jpg)
Distributed Systems
Smaller Refriger
ant Charge
![Page 13: 1. LOW COST 2. SIMPLE 3. EFFICIENT](https://reader036.vdocuments.site/reader036/viewer/2022062501/568165f8550346895dd92349/html5/thumbnails/13.jpg)
Frio Verde and R22 to R404A conversions.
1. Some stores are converting R22 to R404A.
2. Standard R404A has 66% more mass flow than R22 for the same heat transfer.
3. The mass flow increase calls for suction line re-piping with standard R404A systems.
4. Frio Verde R404A has the same mass flow as R22 due to subcooling at 50 ºF to 60 Deg ºF.
5. Frio Verde saves $30k to $40k of re-piping cost on a 50,000 sq ft. supermarket conversion.
![Page 14: 1. LOW COST 2. SIMPLE 3. EFFICIENT](https://reader036.vdocuments.site/reader036/viewer/2022062501/568165f8550346895dd92349/html5/thumbnails/14.jpg)
1. LOW COST 2. SIMPLE
3. EFFICIENT