dnd and mur flush mounted control 0 675 93 h4653 … · en 50090-2-2 en 50090-2-3 en 50428...
TRANSCRIPT
![Page 1: DND and MUR flush mounted control 0 675 93 H4653 … · EN 50090-2-2 EN 50090-2-3 EN 50428 Standards, Certifications, Marks. 2 MM00775-a- 02/10/2013 H4653 LN4653 0 675 93 100% 0%](https://reader031.vdocuments.site/reader031/viewer/2022022016/5b5d71c07f8b9ac6028e51b8/html5/thumbnails/1.jpg)
1
H4653LN4653
02/10/2013MM00775-a-
2
3
1
4
0 675 93
EN
Legend
1. LED adjustment/disable pushbutton
2. LED:AXOLUTE/ARTEOR/CÉLIANE: BLUE: message not active PURPLE: message activeLIVINGLIGHT: GREEN: message not active ORANGE: message active
3. Clamps for connection to the SCS BUS
4. Configurator socket
Front view
Flush mounted control for installation inside the room, for the activation of the “Do Not Disturb” or “Make Up Room” notifications on the indicator outside the door.The device can be configured in two different ways:- Physical configuration, by inserting the configurators in the appropriate housings.- Configuration using the MyHOME_Suite software, which can be downloaded from
the website www.homesystems-legrandgroup.com; this last type of configuration has the advantage of offering many more options when compared with the physical.configuration.
Description
Power supply from SCS BUS: 18 – 27 VdcAbsorption: max. 7.5 mAOperating temperature: (-5) – (+45) °C
Technical data
DND and MUR flush mounted controlBUS-SCS
Size: 2 flush mounted modules
Dimensional data
Rear view
EN 60669-2-1EN 50090-2-2EN 50090-2-3EN 50428
Standards, Certifications, Marks
![Page 2: DND and MUR flush mounted control 0 675 93 H4653 … · EN 50090-2-2 EN 50090-2-3 EN 50428 Standards, Certifications, Marks. 2 MM00775-a- 02/10/2013 H4653 LN4653 0 675 93 100% 0%](https://reader031.vdocuments.site/reader031/viewer/2022022016/5b5d71c07f8b9ac6028e51b8/html5/thumbnails/2.jpg)
2
02/10/2013MM00775-a-
H4653LN4653
0 675 93
100%
0%
30%
60%
2 3 4 5 61
DC - In
MH201
MH201
EN
DND and MUR flush mounted controlBUS-SCS
R1
R2
M
M = 0 DND and MUR active - 2 x 1 module key covers MURDND
M = 1 DND control only - 1 double key cover DND
Physical configuration
R1, R2 = Room address (R1 identifies the tenths; R2 identifies the units)
LED brightness adjustment
DEFAULT
PUSH t > 2 s
This is performed using the appropriate MyHOME_Suite application. This mode has the advantage of offering many more options when compared with the physical configuration. The software configuration requires Ethernet connection between the system and the PC, through the IP MH201 scenario module.
Configuration using the MyHOME_Suite software
Ethernet connection to the system
HUB Switch
BUS-SCS
PC for configuration
Ethernet network
Ethernet network
![Page 3: DND and MUR flush mounted control 0 675 93 H4653 … · EN 50090-2-2 EN 50090-2-3 EN 50428 Standards, Certifications, Marks. 2 MM00775-a- 02/10/2013 H4653 LN4653 0 675 93 100% 0%](https://reader031.vdocuments.site/reader031/viewer/2022022016/5b5d71c07f8b9ac6028e51b8/html5/thumbnails/3.jpg)
3
23
45
61
DC
- In
PRI
SCS
E49
PRI:
220
– 24
0 V~
185
– 1
75 m
A
50/6
0 Hz
SCS:
27
Vdc
60
0 m
A
MH2
01
MO
DE
+ – FAN
DN
DM
UR
02/10/2013MM00775-a-
H4653LN4653
0 675 93
R1=
2R2
=7
M=
2L
=0
A=
1PL
=1
T=
2A
=1
PL=
1M
=PU
L
R1=
2R2
=7
M=
–
A=
9PL
=8
M=
CEN
LED
=–
A=
9PL
=9
M1=
CEN
DEL1
=–
M2=
–DE
L2=
–
ZA=
2ZB
=7
N=
1LO
AD=
–
ZA=
2ZB
=7
TYPE
=1
HEAT
=7
COOL
=CE
NPU
MP=
–IN
=3
MH20
1
E49
230 V
50
Hz
L N
H465
1LN
4651
0 675
91
3482
100 6
75 89
F411
/1N
230 V
acH4
648
LN46
480 6
75 66
5 727
365 7
22 36
F430
R8
L N
BC
D
E
A
F
LL1
H469
1LN
4691
0 674
59
H465
3LN
4653
0 675
93
H465
2 LN
4652
0 675
92
3513
N L V1 V2 V3
EN
DND and MUR flush mounted controlBUS-SCS
Wiring diagrams
To ot
her
room
serv
ices
HUB S
witch
Othe
r roo
ms
PC fo
r roo
m m
anag
emen
t
To th
e fan
-coil
or te
mpe
ratu
re
cont
rol s
ystem
WIN
DOW
OP
EN
ON ECO
BUS S
CS To ot
her
devic
es
Ethern
etne
twor
k
Ethe
rnet
netw
ork
ATh
e gen
eral s
witch
GS (T
M+EL
) mus
t be
selec
ted ba
sed o
n the
abso
rptio
n of
the s
ervic
es in
stalle
d.
BTh
e TM
switc
h mus
t be s
electe
d bas
ed
on th
e pow
er su
pply
used
.
C
DTh
e TM
switc
h mus
t be s
electe
d bas
ed
on th
e loa
ds co
nnec
ted.
ETh
e actu
ator
to be
used
depe
nds o
n th
e typ
e of a
ir con
dition
ing sy
stem
ins
talle
d.
FIf t
he cu
rrent
supp
lied b
y the
E49
is no
t suf
ficien
t to p
ower
the S
CS
syste
m, it
is po
ssible
to us
e the
E4
6ADC
N po
wer s
upply
.
ITEM
DESC
RIPT
ION
E49
Powe
r sup
ply
LN46
51Ke
y car
d rea
der o
utsid
e the
door
and
indica
tors
3482
10Ke
y car
dLN
4648
Key c
ard s
witch
LN46
53DN
D and
MUR
cont
rols
LN46
528 k
ey sc
enar
io co
ntro
lLN
4691
Therm
osta
t with
disp
layMH
201
IP sce
nario
mod
uleF4
30R8
Air c
ondit
ioning
actu
ator
F411
/1N
DIN
mod
ule 1
relay
actu
ator
Gene
ral n
ote:
the d
evice
s list
ed in
the l
egen
d are
for
the L
iving
Light
serie
s.
Principle and configuration diagram for a hotel room
WIN
DOW
CL
OSED
Room
door
ele
ctric
lock
2 sec
.
Bell
12 Va
c/dc –
230 V
acm
ax 1A
Trans
form
erTra
nsfor
mer
Prot
ectio
n lin
eNC
cont
act
Magn
etMa
gnet
Cont
act
Cont
act
CORR
IDOR
RECE
PTIO
N
ROOM
Heat
ing
Cooli
ng
TM3
TM1
TM2
GS
(TM+
EL)